A.2 Fixed Reference Channels for dynamic range (16QAM, R=2/3)

36.1413GPPBase Station (BS) conformance testingEvolved Universal Terrestrial Radio Access (E-UTRA)Release 17TS

The parameters for the reference measurement channels are specified in Table A.2-1 for dynamic range.

Table A.2-1: FRC parameters for dynamic range

Reference channel

A2-1

A2-2

A2-3

A2-4

A2-5

Allocated resource blocks

6

15

25

101

102

DFT-OFDM Symbols per subframe

12

12

12

12

12

Modulation

16QAM

16QAM

16QAM

16QAM

16QAM

Code rate

2/3

2/3

2/3

2/3

2/3

Payload size (bits)

2344

5992

9912

4008

4008

Transport block CRC (bits)

24

24

24

24

24

Code block CRC size (bits)

0

0

24

0

0

Number of code blocks – C

1

1

2

1

1

Coded block size including 12bits trellis termination (bits)

7116

18060

14988

12108

12108

Total number of bits per sub-frame

3456

8640

14400

5760

5760

Total symbols per sub-frame

864

2160

3600

1440

1440

NOTE 1: For reference channel A2-4, the allocated RB’s are uniformly spaced over the channel bandwidth at RB index N, N+5, N+10, …, N+45 where N = {0, 1, 2, 3, 4}.

NOTE 2: For reference channel A2-5, the allocated RB’s are uniformly spaced over the channel bandwidth at RB index N, N+10, N+20, …, N+90 where N = {0, 1, 2, … 9}.