B.1. Conditions for Idle mode tasks

25.1333GPPRelease 17Requirements for support of radio resource management (FDD)TS

B.1.1. Conditions for measurements of inter-RAT E-UTRA cells

This section defines the inter-RAT E-UTRA RSRP, RSRP Ês/Iot, SCH_RP and SCH Ês/Iot applicable for a corresponding operating band.

The conditions for measurements of inter-RAT E-UTRA cells are defined in Table B.1.1-1

Table B.1.1-1: Conditions for measurements of inter-RAT E-UTRA cells

Conditions

Band groups Conditions

Parameters

RSRP|dBm

SCH_RP|dBm

RSRP Ês/Iot≥

SCH Ês/Iot ≥

FDD_A, TDD_A

-124 dBm

-124 dBm

-4 dB

-4dB

FDD_B1, FDD_B2

-123.5 dBm
(Note 2)

-123.5 dBm
(Note 2)

FDD_C, TDD_C

-123 dBm

-123 dBm

FDD_E, TDD_E

-122 dBm

-122 dBm

FDD_G

-121 dBm

-121 dBm

FDD_H

-120.5 dBm

-120.5 dBm

FDD_F

-121.5 dBm
(Note 1)

-121.5 dBm
(Note 1)

FDD_D

-122.5 dBm

-122.5 dBm

Note 1: The condition is -122 dBm when the carrier frequency of the assigned E-UTRA channel bandwidth is within 865-894 MHz.