A.5.10 Intrafrequency System information acquisition for CSG cell

25.1333GPPRelease 17Requirements for support of radio resource management (FDD)TS

A.5.10.1 Test Purpose and Environment

The purpose of this test is to verify the requirement for intrafrequency CSG SI acquisition in section 5.13.2. The test parameters are given in Table A.5.17 and A.5.18 below. In the measurement control information cell 2 shall be included in the "Intra-frequency SI Acquisition" IE. The test consists of two successive time periods, with time duration of T1 and T2 respectively. At the start of time duration T1, the UE may not have any timing information of cell 2.

Table A.5.17: General test parameters for intrafrequency CSG SI acquisition

Parameter

Unit

Value

Comment

DCH parameters

DL and UL Reference Measurement Channel 12.2 kbps

As specified in TS 25.101 section A.3.1 and A.2.1

Power Control

On

Target quality value on DTCH

BLER

0.01

Initial conditions

Active cell

Cell 1

Neighbouring cell

Cell 2

Final condition

Active cell

Cell 1

Handover to cell 2 is not requested

Reporting range

dB

3

Applicable for event 1A

Hysteresis

dB

0

W

1

Applicable for event 1A

Reporting deactivation threshold

0

Applicable for event 1A

Time to Trigger

Ms

0

SIB3_REP

Frames

32

Applicable for cell 2 SIB3 scheduling

SIB3 SEG_COUNT

1

Applicable for cell 2 SIB3 scheduling

UE whitelist

Empty

Monitored cell list size

24 on channel 1

Measurement control information is sent before the start of the test

CSG id (of cell 2)

Set to any non-empty value

Filter coefficient

0

T1

S

5

T2

S

5

Table A.5.18: Cell specific test parameters for intrafrequency CSG SI acquisition

Parameter

Unit

Cell 1

Cell 2

T1

T2

T1

T2

CPICH_Ec/Ior

dB

-10

-10

PCCPCH_Ec/Ior

dB

-12

-12

SCH_Ec/Ior

dB

-12

-12

PICH_Ec/Ior

dB

-15

-15

DPCH_Ec/Ior

dB

Note 1

N/A

OCNS

Note 2

-0.941

dB

0

6.97

-Infinity

5.97

dBm/ 3,84 MHz

-63.01

-70

Note 3

Note 3

CPICH_Ec/Io

dB

-13

-Infinity

-14

Propagation Condition

AWGN

Note 1: The DPCH level is controlled by the power control loop

Note 2: The power of the OCNS channel that is added shall make the total power from the cell to be equal to Ior .

Note 3: The Ioc level is common for cell 1 and cell 2

A.5.10.2 Test Requirements

The UE shall transmit an Event 1A-triggered measurement report containing the cell identity and CSG identity of cell 2 and membership indication sent to false within [2.71] seconds from the start of T2

Test requirement = Tidentify intra+ TCSG-SI-Report

= 800+ [630]+40*32 from the start of T2

= [2.71] seconds.

The UE shall not send event triggered measurement reports, as long as the reporting criteria are not fulfilled..

The rate of correct events observed during repeated tests shall be at least 90%.

NOTE: The actual overall delays measured in the test may be up to 2 x TTIUL DCCH higher than the measurement reporting delays above because of TTI insertion uncertainty of the measurement report in the UL DCCH.

The measured quality on the DTCH of the UE downlink during T2 shall not exceed BLER=0.01±30% = 0.013