A.5.10 Intrafrequency System information acquisition for CSG cell
25.1333GPPRelease 17Requirements for support of radio resource management (FDD)TS
A.5.10.1 Test Purpose and Environment
The purpose of this test is to verify the requirement for intrafrequency CSG SI acquisition in section 5.13.2. The test parameters are given in Table A.5.17 and A.5.18 below. In the measurement control information cell 2 shall be included in the "Intra-frequency SI Acquisition" IE. The test consists of two successive time periods, with time duration of T1 and T2 respectively. At the start of time duration T1, the UE may not have any timing information of cell 2.
Table A.5.17: General test parameters for intrafrequency CSG SI acquisition
Parameter |
Unit |
Value |
Comment |
|
DCH parameters |
DL and UL Reference Measurement Channel 12.2 kbps |
As specified in TS 25.101 section A.3.1 and A.2.1 |
||
Power Control |
On |
|||
Target quality value on DTCH |
BLER |
0.01 |
||
Initial conditions |
Active cell |
Cell 1 |
||
Neighbouring cell |
Cell 2 |
|||
Final condition |
Active cell |
Cell 1 |
Handover to cell 2 is not requested |
|
Reporting range |
dB |
3 |
Applicable for event 1A |
|
Hysteresis |
dB |
0 |
||
W |
1 |
Applicable for event 1A |
||
Reporting deactivation threshold |
0 |
Applicable for event 1A |
||
Time to Trigger |
Ms |
0 |
||
SIB3_REP |
Frames |
32 |
Applicable for cell 2 SIB3 scheduling |
|
SIB3 SEG_COUNT |
1 |
Applicable for cell 2 SIB3 scheduling |
||
UE whitelist |
Empty |
|||
Monitored cell list size |
24 on channel 1 |
Measurement control information is sent before the start of the test |
||
CSG id (of cell 2) |
Set to any non-empty value |
|||
Filter coefficient |
0 |
|||
T1 |
S |
5 |
||
T2 |
S |
5 |
Table A.5.18: Cell specific test parameters for intrafrequency CSG SI acquisition
Parameter |
Unit |
Cell 1 |
Cell 2 |
||
T1 |
T2 |
T1 |
T2 |
||
CPICH_Ec/Ior |
dB |
-10 |
-10 |
||
PCCPCH_Ec/Ior |
dB |
-12 |
-12 |
||
SCH_Ec/Ior |
dB |
-12 |
-12 |
||
PICH_Ec/Ior |
dB |
-15 |
-15 |
||
DPCH_Ec/Ior |
dB |
Note 1 |
N/A |
||
OCNS |
Note 2 |
-0.941 |
|||
|
dB |
0 |
6.97 |
-Infinity |
5.97 |
|
dBm/ 3,84 MHz |
-63.01 |
-70 |
Note 3 |
Note 3 |
CPICH_Ec/Io |
dB |
-13 |
-Infinity |
-14 |
|
Propagation Condition |
AWGN |
||||
Note 1: The DPCH level is controlled by the power control loop Note 2: The power of the OCNS channel that is added shall make the total power from the cell to be equal to Ior . Note 3: The Ioc level is common for cell 1 and cell 2 |
A.5.10.2 Test Requirements
The UE shall transmit an Event 1A-triggered measurement report containing the cell identity and CSG identity of cell 2 and membership indication sent to false within [2.71] seconds from the start of T2
Test requirement = Tidentify intra+ TCSG-SI-Report
= 800+ [630]+40*32 from the start of T2
= [2.71] seconds.
The UE shall not send event triggered measurement reports, as long as the reporting criteria are not fulfilled..
The rate of correct events observed during repeated tests shall be at least 90%.
NOTE: The actual overall delays measured in the test may be up to 2 x TTIUL DCCH higher than the measurement reporting delays above because of TTI insertion uncertainty of the measurement report in the UL DCCH.
The measured quality on the DTCH of the UE downlink during T2 shall not exceed BLER=0.01±30% = 0.013