A.8.5A CSG Proximity Indication Testing Case for UTRAN FDD – FDD Inter frequency

25.1333GPPRelease 17Requirements for support of radio resource management (FDD)TS

Note : The test case in this section forms the basis for a signalling test for CSG proximity detection.

A.8.5A.1 Test Purpose and Environment

The purpose of this test is to verify the UE has implemented properly the feature for indicating that the UE is entering or leaving the proximity of one or more CSG member cells based on proximity detection with an autonomous search function as defined by the requirements in Section 6.7.

The test case consists of three successive segments: Test Preparation, Negative Test, and Positive Test. The test scenario comprises of three UTRAN FDD cells on different carriers. Cell 1 represents the serving cell in the proximity of the CSG cell, Cell 2 the CSG cell and Cell 3 the serving cell not in the proximity of the CSG cell. The description of the test procedure is shown in Table A.8.5A-1. The general test parameters and cell specific test parameters are presented in Table A.8.5A-2 and Table A.8.5A-3 respectively.

Table A.8.5A-1: Description of the test procedures

Parameter

Cell Status

Comment

Test Preparation

Initial Condition

Cell 1 is active

Clean up the UE memory to be free from previously stored cell information for proximity detection.

Turn on the UE and allow sufficient time for the UE to reselect to Cell 1.

Time duration T1

Cell 1 and Cell 2 are active

Turn on Cell 2 at the start of T1.

Perform manual CSG selection towards Cell 2. The UE is expected to store necessary information for later proximity detection.

End condition

Turn off the UE. Turn off Cell 1 and Cell 2.

Negative Test

Initial Condition

Cell 3 is active

Turn on Cell 3.

Turn on the UE and set up the UE in connected mode with Cell 3

Time duration T2

Cell 3 is active

Configure the UE with proximity indication control by sending the Measurement Control message to enable CSG Proximity detection at the start of T2. The UE is not expected to report “entering” proximity in the negative test.

End condition

Turn off the UE. Turn off Cell 3.

Positive Test

Initial Condition

Cell 1 is active

Turn on Cell 1.

Turn on the UE and set up the UE in connected mode with Cell 1

Time duration T3

Cell 1 and Cell 2 are active

Turn on Cell 2 at the start of T3.

Configure the UE with proximity indication control by sending the Measurement Control message to enable CSG Proximity at the start of T3. The UE is expected to report “entering” proximity before end of T3.

Time duration T4

Cell 1 is active and Cell 3 are active

Turn off Cell 2 and turn on Cell 3 at the start of T4.

Hand the UE overNote 1from Cell 1 to Cell 3 .

(Note: The UE may report “leaving” proximity in T4. In this case, there is no need to proceed to the next step.).

Time duration T5

Cell 3 are active

Turn off Cell 1 at the start of T5. The procedures in T4 and T5 together simulate the situation that UE leaves the proximity of the CSG cell. The UE is expected to report “leaving” proximity before end of T5..

End condition

Turn off the UE. Turn off Cell 1 and Cell 3.

Note 1: The handover from Cell 1 to Cell 3 must preserve the proximity configuration (i.e. must involve neither SR-VCC handover, nor SRNS relocation, as described in [16])

Table A.8.5A-2: General test parameters for UTRAN FDD-FDD inter frequency cell proximity indication test case

Parameter

Unit

Value

Comment

DCH parameters

DL and UL Reference Measurement Channel 12.2 kbps

As specified in TS 25.101 section A.3.1 and A.2.1

Power Control

On

Target quality value on DTCH

BLER

0.001

Compressed mode

A.22 set 1

As specified in TS 25.101 section A.5.

Initial conditions

Active cell

Cell 1

Neighbour cell

Cell 2

Final conditions

Active cell

Cell 1

Handover to cell 2 is not requested

Threshold non used frequency

dB

-18

Absolute Ec/I0 threshold for event 2C

Hysteresis

dB

0

W non-used frequency

1

Applicable for event 2C

Time to Trigger

Ms

0

Filter coefficient

0

SIB3_REP

Frames

32

Applicable for cell 2 SIB3 scheduling

SIB3 SEG_COUNT

1

Applicable for cell 2 SIB3 scheduling

CSG id (of cell 2)

Set to any non-empty value

CSG Indicator (of cell 2)

Set to TRUE

UE whitelist

Include Cell 2

Monitored cell list size

24 on channel 1

16 on channel 2

Measurement control information is sent before the compressed mode pattern starts.

Time duration T1

s

[10]

Defined to give enough time for the UE to complete the registration to Cell 2.

Time duration T2

s

[360]

Defined to be longer enough to see whether the UE will report enter “proximity” indication.

Time duration T3 Note 1

s

[<=360]

The time duration for a UE to report enters “proximity” when the UE is near a CSG cell.

Time duration T4 Note 1

s

[<=360]

The time duration for a UE to be handed over to Cell 3.

Time duration T5 Note 1

s

[<=360]

The time duration for a UE to report leaving “proximity” when the UE is no longer near a CSG cell.

Note 1: The maximum allowed time duration for the UE to decide either entering or leaving “proximity” is 360s. To reduce test time, T3 may end once UE reports entering “proximity”, T4 may end once the UE is handed over to Cell 3 and T5 may end once UE reports leaving “proximity”.

Note 2: The test case assumes an environment where CSG proximity detection results not being impact by non-3GPP signals, such as GPS and WiFi. When the test case is being executed, the UE may ignore any radio signals which are not provided by the test setup which it would otherwise use in proximity estimation.

Table A.8.5A-3: Cell specific test parameters for UTRAN FDD-FDD inter frequency cell proximity indication test case (Cell 1 and Cell 2)

Parameter

Unit

Cell 1

Cell 2

T1

T2

T3

T4

T5

T1

T2

T3

T4

T5

UARFCN Note1

Channel 1

Channel 2

CSG indicator

False

True

N/A

True

N/A

N/A

Primary scrambling code Note1

1

1

1

1

1

2

N/A

2

N/A

N/A

CSG identity

Not sent

Sent

N/A

Sent

N/A

N/A

BWchannel

MHz

10

10

CPICH_Ec/Ior

dB

-10

[-6]

PCCPCH_Ec/Ior

dB

-12

[-8]

CPICH_Ec/Io

dB

-13

[-9]

SCH_Ec/Ior

dB

-15

[-11]

PICH_Ec/Ior

dB

-15

[-11]

DPCH_Ec/Ior

dB

Note 2

N/A

Note 2

Note 2

N/A

Note 2

N/A

Note 2

N/A

N/A

dB

0

-inf

0

0

-inf

-1.8

-inf

-1.8

-inf

-inf

dBm/3.84 MHz

-70

-70

OCNS

Note 3

N/A

Note 3

Note 3

N/A

-0.941

N/A

-0.941

N/A

N/A

Propagation Condition

AWGN

AWGN

Note 1: For this requirement to be applicable, and scrambling code for cell 1 and cell 2 shall be unchanged from when the CSG cell was visited previously

Note 2: The DPCH level is controlled by the power control loop

Note 3: The power of the OCNS channel that is added shall make the total power from the cell to be equal to Ior .

Table A.8.5A-4: Cell specific test parameters for UTRAN FDD-FDD inter frequency cell proximity indication test case (Cell 3)

Parameter

Unit

Cell 3

T1

T2

T3

T4

T5

UARFCN Note1

Channel 1

CSG indicator

False

Primary scrambling code Note1

3

3

3

3

3

CSG identity

Not Sent

BWchannel

MHz

10

CPICH_Ec/Ior

dB

-10

PCCPCH_Ec/Ior

dB

-12

CPICH_Ec/Io

dB

-13

SCH_Ec/Ior

dB

-15

PICH_Ec/Ior

dB

-15

DPCH_Ec/Ior

dB

N/A

N/A

N/A

Note 2

Note 2

dB

-inf

-inf

-inf

2

2

dBm/3.84 MHz

-70

OCNS

N/A

N/A

N/A

Note 3

Note 3

Propagation Condition

AWGN

Note 1: For this requirement to be applicable, and scrambling code for cell 1 and cell 2 shall be unchanged from when the CSG cell was visited previously

Note 2: The DPCH level is controlled by the power control loop

Note 3: The power of the OCNS channel that is added shall make the total power from the cell to be equal to Ior

A.8.5A.2 Test Requirements

The UE shall not send an “entering” proximity indication in T2 during Negative Test.

The UE shall send an “entering” proximity indication in T3 and send a “leaving” proximity indication in T4 or T5 during Positive Test.