A.8.4 GSM measurements

25.1333GPPRelease 17Requirements for support of radio resource management (FDD)TS

A.8.4.1 Correct reporting of GSM neighbours in AWGN propagation condition

A.8.4.1.1 Test Purpose and Environment

The purpose of these tests is to verify that the UE makes correct reporting of an event when doing inter-RAT GSM measurements. The test will partly verify the requirements in section 8.1.2.5. The requirements are also applicable for a UE not requiring compressed mode, in which case no compressed mode pattern should be sent for the parameters specified in table A8.15.

The test consists of three successive time periods, with a time duration T1, T2 and T3. The test parameters are given in tables A.8.15, A.8.16 and A.8.17 below. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 3B and 3C shall be used.

A.8.4.1.1.1 Test 1. With BSIC verification required

Table A.8.15: General test parameters for Correct reporting of GSM neighbours in AWGN propagation condition, Test 1

Parameter

Unit

Value

Comment

DCH parameters

DL Reference Measurement Channel 12.2 kbps

As specified in TS 25.101 section A.3.1

Power Control

On

Target quality value on DTCH

BLER

0.01

Compressed mode patterns

– GSM carrier RSSI measurement

– GSM Initial BSIC identification

DL Compressed mode reference pattern 2 in Set 2

Pattern 2

Only applicable for UE requiring compressed mode patterns

As specified in table A.22 TS 25.101 section A.5

As specified in section 8.1.2.5.2.1 table 8.7.

Active cell

Cell 1

Inter-RAT measurement quantity

GSM Carrier RSSI

BSIC verification required

required

Threshold other system

dBm

-80

Absolute GSM carrier RSSI threshold for event 3B and 3C.

Hysteresis

dB

0

Time to Trigger

ms

0

Filter coefficient

0

Monitored cell list size

24 FDD neighbours on Channel 1

6 GSM neighbours including ARFCN 1

Measurement control information is sent before the compressed mode patterns starts.

N Identify abort

66

Taken from table 8.7.

T1

s

5

T2

s

7

T3

s

5

Table A.8.16: Cell specific test parameters for Correct reporting of GSM neighbours in AWGN propagation condition (cell 1)

Parameter

Unit

Cell 1

T1, T2, T3

UTRA RF Channel Number

Channel 1

CPICH_Ec/Ior

dB

-10

PCCPCH_Ec/Ior

dB

-12

SCH_Ec/Ior

dB

-12

PICH_Ec/Ior

dB

-15

DPCH_Ec/Ior

dB

Note 1

OCNS

Note 2

dB

0

dBm/3,84 MHz

-85

CPICH_Ec/Io

dB

-13

Propagation Condition

AWGN

Note 1: The DPCH level is controlled by the power control loop.

Note 2: The power of the OCNS channel that is added shall make the total power from the cell to be equal to Ior.

Table A.8.17: Cell specific test parameters for Correct reporting of GSM neighbours in AWGN propagation condition (cell 2)

Parameter

Unit

Cell 2

T1

T2

T3

Absolute RF Channel Number

ARFCN 1

RXLEV

dBm

-Infinity

-75

-85

A.8.4.1.1.2 Test 2: Without BSIC verification required

Table A.8.18: General test parameters for Correct reporting of GSM neighbours in AWGN propagation condition, Test 2

Parameter

Unit

Value

Comment

DCH parameters

DL Reference Measurement Channel 12.2 kbps

As specified in TS 25.101 section A.3.1

Power Control

On

Target quality value on DTCH

BLER

0.01

Compressed mode patterns

– GSM carrier RSSI measurement

DL Compressed mode reference pattern 2 in Set 2

Only applicable for UE requiring compressed mode patterns

As specified in table A.22 TS 25.101 section A.5

Active cell

Cell 1

Inter-RAT measurement quantity

GSM Carrier RSSI

BSIC verification required

not required

Threshold other system

dBm

-80

Absolute GSM carrier RSSI threshold for event 3B and 3C.

Hysteresis

dB

0

Time to Trigger

ms

0

Filter coefficient

0

Monitored cell list size

24 FDD neighbours on Channel 1

6 GSM neighbours including ARFCN 1

Measurement control information is sent before the compressed mode patterns starts.

T1

s

5

T2

s

2

T3

s

5

Table A.8.19: Cell specific test parameters for Correct reporting of GSM neighbours in AWGN propagation condition (cell 1)

Parameter

Unit

Cell 1

T1, T2, T3

UTRA RF Channel Number

Channel 1

CPICH_Ec/Ior

dB

-10

PCCPCH_Ec/Ior

dB

-12

SCH_Ec/Ior

dB

-12

PICH_Ec/Ior

dB

-15

DPCH_Ec/Ior

dB

Note 1

OCNS

Note 2

dB

0

dBm/ 3,84 MHz

-85

CPICH_Ec/Io

dB

-13

Propagation Condition

AWGN

NOTE 1: The DPCH level is controlled by the power control loop.

NOTE 2: The power of the OCNS channel that is added shall make the total power from the cell to be equal to Ior.

Table A.8.20: Cell specific test parameters for Correct reporting of GSM neighbours in AWGN propagation condition (cell 2)

Parameter

Unit

Cell 2

T1

T2

T3

Absolute RF Channel Number

ARFCN 1

RXLEV

dBm

-Infinity

-75

-85

A.8.4.1.2 Test Requirements

A.8.4.1.2.1 TEST 1 With BSIC verification required

The UE shall send one Event 3C triggered measurement report for Cell2, with a measurement reporting delay less than 6.24 s from the beginning of time period T2.

The UE shall send one Event 3B triggered measurement report for Cell2, with a measurement reporting delay less than 960 ms from the beginning of time period T3.

The UE shall not send event triggered measurement reports, as long as the reporting criteria are not fulfilled.

The rate of correct events observed during repeated tests shall be at least 90%.

A.8.4.1.2.2 TEST 2 Without BSIC verification required

The UE shall send one Event 3C triggered measurement report for Cell2, with a measurement reporting delay less than 960 ms from the beginning of time period T2.

The UE shall send one Event 3B triggered measurement report for Cell2, with a measurement reporting delay less than 960 ms from the beginning of time period T3.

The UE shall not send event triggered measurement reports, as long as the reporting criteria are not fulfilled.

The rate of correct events observed during repeated tests shall be at least 90%.