E.0 BC3 CS3 Test model description

37.1413GPPMulti-Standard Radio (MSR) Base Station (BS) conformance testingNR, E-UTRA, UTRA and GSM/EDGERelease 17TS

The set-up of physical channels for E-UTRA TDD in part of BC3 CS3, BC3 CS16 and BC3 CS17 (and CS2 when NB-IoT in-band and/or guard band is supported) BS transmitter tests shall be according to the applicable test models shown below. A detailed reference to the applicable test model is made in clause 4.9.2.

The parameters in 36.141 clause 6.1.1 shall be reused by the test models in E.1 to E.6 (E.2 shall not be used for BC3 CS2 BS testing when NB-IoT in-band and/or guard band is supported) with the following exceptions,

– Duration is 30 subframes (30ms), e.g. number of frames for the test model is 3.

– Uplink/downlink configuration 1 and special subframe configuration 7 shall be used as shown in table E-1.

Table E-1: Configurations

Downlink-to-Uplink

Number of UL/DL sub-frames per half frame (10 ms)

DwPTS

GP

UpPTS

Switch-point periodicity

DL

UL

a) 5ms

a) 2

a) 2

a)

The test models in E.1 to E.6 shall be constructed based on the corresponding test model in 36.141 along with the principles on data mapping between the test models in E.1 to E.6 and the test models in 36.141 Clause 6.1.1.1 to 6.1.1.6 as shown in Table E-2.

Table E-2: Numbers () of the boosted PRBs

Frame1

Subframe 0

Subframe 1

Subframe 4

Subframe 5

Subframe 6

Subframe 9

Note

NOTE 1

NOTE 1

NOTE 2

NOTE 1

NOTE 3

NOTE 1

Frame2

Subframe 0

Subframe 1

Subframe 4

Subframe 5

Subframe 6

Subframe 9

Note

NOTE 1

NOTE 1

NOTE 4

NOTE 1

NOTE 3

NOTE 1

Frame3

Subframe 0

Subframe 1

Subframe 4

Subframe 5

Subframe 6

Subframe 9

Note

NOTE 5

NOTE 3

NOTE 6

NOTE 7

NOTE 3

NOTE 8

NOTE 1: The data in this subframe shall re-use the same data as specified in the corresponding subframe of the corresponding test models in 36.141 clause 6.1.1.

NOTE 2: The data in this subframe shall re-use the same data as specifiedin subframe 7 of Frame 1 in the corresponding test model in 36.141 clause 6.1.1.

NOTE 3: The data in this subframe shall re-use the same data as specified in subframe 1 of Frame 1 in the corresponding test model in 36.141 clause 6.1.1.

NOTE 4: The data in this subframe shall re-use the same data as specifiedin subframe 8 of Frame 1 in the corresponding test model in 36.141 clause 6.1.1.

NOTE 5: The data in this subframe shall re-use the same data as specifiedin subframe 7 of Frame 2 in the corresponding test model in 36.141 clause 6.1.1.

NOTE 6: The data in this subframe shall re-use the same data as specified in subframe 8 of Frame 2 in the corresponding test model in 36.141 clause 6.1.1.

NOTE 7: The data in this subframe shall re-use the same data as specified in subframe 6 of Frame 1 in the corresponding test model in 36.141 clause 6.1.1.