B.2 Normal test environment

37.1413GPPMulti-Standard Radio (MSR) Base Station (BS) conformance testingNR, E-UTRA, UTRA and GSM/EDGERelease 17TS

When a normal test environment is specified for a test, the test should be performed within the minimum and maximum limits of the conditions stated in Table B.1.

Table B.1: Limits of conditions for Normal Test Environment

Condition

Minimum

Maximum

Barometric pressure

86 kPa

106 kPa

Temperature

15°C

30°C

Relative Humidity

20 %

85 %

Power supply

Nominal, as declared by the manufacturer

Vibration

Negligible

The ranges of barometric pressure, temperature and humidity represent the maximum variation expected in the uncontrolled environment of a test laboratory. If it is not possible to maintain these parameters within the specified limits, the actual values shall be recorded in the test report.