A.3 E-UTRA interfering signal
37.1413GPPMulti-Standard Radio (MSR) Base Station (BS) conformance testingNR, E-UTRA, UTRA and GSM/EDGERelease 17TS
The E-UTRA interfering signal shall be a PUSCH containing data and reference symbols. Normal CP is used. The data content shall be uncorrelated to the wanted signal and modulated according to clause 5 of TS 36.211. Mapping of PUSCH modulation to receiver requirement are specified in Table A.3-1.
Table A.3-1: Modulation of the E-UTRA interfering signal
Receiver requirement |
Modulation |
Narrowband blocking |
QPSK |
Receiver intermodulation |
QPSK |
Annex B (normative):