9.7.5 OTA Operating band unwanted emission
37.1053GPPActive Antenna System (AAS) Base Station (BS) transmission and receptionRelease 17TS
9.7.5.1 General
Unless otherwise stated, for E-UTRA single band and MSR the operating band unwanted emission limits are defined from ΔfOBUE below the lowest frequency of each supported downlink operating band to the lower Base Station RF Bandwidth edge located at FBW RF,low and from the upper Base Station RF Bandwidth edge located at FBW RF,high up to ΔfOBUE above the highest frequency of each supported downlink operating band. The values of ΔfOBUE are defined in table 9.7.1-1.
The requirements shall apply whatever the type of transmitter considered and for all transmission modes foreseen by the manufacturer’s specification.
The operating band unwanted emissions minimum requirements are quoted as TRP per RIB unless otherwise stated.
The requirements shall apply whatever the type of RIB is considered (single carrier or multi-carrier) and for all transmission modes foreseen by the manufacturer’s specification. In addition, for a RIB operating in non-contiguous spectrum, the requirements apply inside any sub-block gap. In addition, for a multi-band RIB the requirements apply inside any Inter RF Bandwidth gap.
The unwanted emission limits in the part of the downlink operating band that falls in the spurious domain are consistent with ITU-R Recommendation SM.329 [14].
Additional limits in clause 9.7.5.2.4.7 may apply outside OBUE frequency domain.
Emissions shall use the minimum requirements specified in the tables below, where:
– Δf is the separation between the channel edge frequency and the nominal -3dB point of the measuring filter closest to the carrier frequency.
– f_offset is the separation between the channel edge frequency and the centre of the measuring filter.
– f_offsetmax is the offset to the frequency ΔfOBUE MHz outside the downlink operating band.
– Δfmax is equal to f_offsetmax minus half of the bandwidth of the measuring filter.
For a multi-band RIB inside any Inter RF Bandwidth gaps with Wgap < 2×ΔfOBUE, emissions shall not exceed the cumulative sum of the minimum requirements specified at the Base Station RF Bandwidth edges on each side of the Inter RF Bandwidth gap. The minimum requirement for Base Station RF Bandwidth edge is specified in the subclause 9.7.5.4.2 to 9.7.5.4.7 below, where in this case:
– Δf is the separation between the Base Station RF Bandwidth edge frequency and the nominal -3 dB point of the measuring filter closest to the Base Station RF Bandwidth edge.
– f_offset is the separation between the Base Station RF Bandwidth edge frequency and the centre of the measuring filter.
– f_offsetmax is equal to the Inter RF Bandwidth gap minus half of the bandwidth of the measuring filter.
– Δfmax is equal to f_offsetmax minus half of the bandwidth of the measuring filter.
For multi-band RIB, the operating band unwanted emission limits apply also in a supported operating band without any carrier transmitted, in the case where there are carrier(s) transmitted in another supported operating band. In this case, no cumulative limit is applied in the inter-band gap between a supported downlink operating band with carrier(s) transmitted and a supported downlink operating band without any carrier transmitted and
– In case the inter-band gap between a supported downlink operating band with carrier(s) transmitted and a supported downlink operating band without any carrier transmitted is less than 2×ΔfOBUE, f_offsetmax shall be the offset to the frequency ΔfOBUE MHz outside the outermost edges of the two supported downlink operating bands and the operating band unwanted emission limit of the band where there are carriers transmitted, as defined in the tables of the present subclause, shall apply across both downlink bands.
– In other cases, the operating band unwanted emission limit of the band where there are carriers transmitted, as defined in the tables of the present subclause for the largest frequency offset (Δfmax), shall apply from ΔfOBUE MHz below the lowest frequency, up to ΔfOBUE MHz above the highest frequency of the supported downlink operating band without any carrier transmitted.
For a multicarrier E-UTRA RIB or a RIB configured for intra-band contiguous or non-contiguous carrier aggregation the definitions above apply to the lower edge of the carrier transmitted at the lowest carrier frequency and the upper edge of the carrier transmitted at the highest carrier frequency within a specified frequency band.
In addition, inside any sub-block gap for a RIB operating in non-contiguous spectrum, emissions shall not exceed the cumulative sum of the minimum requirements specified for the adjacent sub blocks on each side of the sub-block gap. The minimum requirement for each sub block is specified in the tables sub-cluase 9.7.5.4.2 to 9.7.5.4.7 below, where in this case:
– Δf is the separation between the sub block edge frequency and the nominal -3 dB point of the measuring filter closest to the sub block edge.
– f_offset is the separation between the sub block edge frequency and the centre of the measuring filter.
– f_offsetmax is equal to the sub-block gap bandwidth minus half of the bandwidth of the measuring filter.
– Δfmax is equal to f_offsetmax minus half of the bandwidth of the measuring filter.
– ΔfOBUE is defined in clause 6.6.1.
9.7.5.2 Minimum requirement for MSR operation
9.7.5.2.1 General
The MSR operating band unwanted emission minimum requirements are given in subclauses 9.7.5.2.2, 9.7.5.2.3, and 9.7.5.2.4.
9.7.5.2.2 Minimum requirements for Band Categories 1 and 3
For an MSR RIB operating in BC1 or BC3 bands, the minimum requirements are specified in tables 9.7.5.2.2-1 to 9.7.5.2.2-4, dependent on BS class and output power.
Applicability of Wide Area operating band unwanted emission requirements in tables 9.7.5.2.2-1, 9.7.5.2.2-1a and 9.7.5.2.2-1b is specified in table 9.7.5.2.2-0.
Table 9.7.5.2.2-0: Applicability of operating band unwanted emission requirements for BC1 and BC3 Wide Area BS
NR band operation |
UTRA supported |
Applicable requirement table |
None |
Y/N |
9.7.5.2.2-1 (option 2) |
In certain regions (NOTE 2), bands 3, 8 |
N |
9.7.5.2.2-1 (option 2) |
Any below 1 GHz except for certain regions (NOTE 2), band 8 |
N |
9.7.5.2.2-1a (option 1) |
Any above 1 GHz except for certain regions (NOTE 2), band 3 |
N |
9.7.5.2.2-1b (option 1) |
NOTE 1: Void. NOTE 2: Applicable only for operation in regions where Category B limits as defined in ITU-R Recommendation SM.329 [14] are used for which category B option 2 operating band unwanted emissions requirements as defined in TS 36.104 [8] and TS 38.104 [27] are applied. |
Table 9.7.5.2.2-1: WA BS OBUE in BC1 and BC3 bands applicable for: BS not supporting NR; or BS supporting NR in Band n1 or n65
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 4) |
0 MHz ≤ Δf < 0.2 MHz |
0.015MHz ≤ f_offset < 0.215MHz |
-5 dBm |
30 kHz |
0.2 MHz ≤ Δf < 1 MHz |
0.215MHz ≤ f_offset < 1.015MHz |
30 kHz |
|
(NOTE 3) |
1.015MHz ≤ f_offset < 1.5 MHz |
-17 dBm |
30 kHz |
1 MHz ≤ Δf ≤ min(Δfmax, 10 MHz) |
1.5 MHz ≤ f_offset < min(f_offsetmax, 10.5 MHz) |
-4 dBm |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm (NOTE 5) |
1 MHz |
NOTE 1: For MSR RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks on each side of the sub-block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10MHz from both adjacent sub-blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -6dBm/MHz. NOTE2: For MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or RF Bandwidth. |
Table 9.7.5.2.2-1a: WA BS OBUE in BC1 and BC3 bands ≤ 1 GHz applicable for: BS supporting NR and not supporting UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (Note 1, 2) |
Measurement bandwidth (Note 4) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
100 kHz |
|
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-5 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-7 dBm (Note 5) |
100 kHz |
NOTE 1: For MSR RIB supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -7dBm/100kHz. NOTE 2: For MSR multi band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 3: For operation with an E-UTRA 1.4 or 3MHz carrier adjacent to the Base Station RF Bandwidth edge, the limits in Table 6.6.2.2-2 apply for 0 MHz ≤ Δf < 0.15 MHz. |
Table 9.7.5.2.2-1b: WA BS OBUE in BC1 and BC3 bands > 1 GHz applicable for: BS supporting NR, not operating in band n1 or n65, and not supporting UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (Note 1, 2) |
Measurement bandwidth (Note 4) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
100 kHz |
|
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-5 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm (Note 5) |
1MHz |
NOTE 1: For MSR RIB supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -6dBm/1MHz. NOTE 2: For MSR multi band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the basic limit within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or RF Bandwidth. NOTE 3: For operation with an E-UTRA 1.4 or 3MHz carrier adjacent to the Base Station RF Bandwidth edge, the limits in Table 6.6.2.2-2 apply for 0 MHz ≤ Δf < 0.15 MHz. |
Table 9.7.5.2.2-2: MR BS OBUE in BC1 bands applicable for: BS with maximum output power 40 < Prated,c,TRP ≤ 47 dBm and not supporting NR
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 4) |
0 MHz ≤ Δf < 0.6 MHz |
0.015MHz ≤ f_offset < 0.615MHz |
Prated,c,TRP – 58dB – (5/3)*(f_offset-0,015) dB |
30 kHz |
0.6 MHz ≤ Δf < 1 MHz |
0.615MHz ≤ f_offset < 1.015MHz |
Prated,c,TRP – 53dB – 15*(f_offset-0,015) dB |
30 kHz |
(NOTE 3) |
1.015MHz ≤ f_offset < 1.5 MHz |
Prated,c,TRP – 65 dB |
30 kHz |
1 MHz ≤ Δf ≤ 2.6 MHz |
1.5 MHz ≤ f_offset < 3.1 MHz |
Prated,c,TRP –52 dB |
1 MHz |
2.6 MHz ≤ Δf ≤ 5 MHz |
3.1 MHz ≤ f_offset < 5.5 MHz |
min(Prated,c,TRP – 52 dB, -6dBm) |
1 MHz |
5 MHz ≤ Δf ≤ Δfmax |
5.5 MHz ≤ f_offset < f_offsetmax |
Prated,c,TRP –56 dB |
1 MHz |
NOTE 1: For MSR RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10MHz from both adjacent sub-blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be (Prated,c,TRP – 56 dB) /MHz. NOTE 2: For MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. |
Table 9.7.5.2.2-2a: MR BS OBUE in BC1 bands applicable for: BS with maximum output power 40 < Prated,c,TRP ≤ 47 dBm BS, supporting NR and not supporting UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (Note 1, 2) |
Measurement bandwidth (Note 4) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
Prated,c,TRP – 53 dB – (7/5)*(f_offset-0,05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
Prated,c,TRP – 60 dB |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
Min(Prated,c,TRP – 60 dB, -16 dBm) (Note 4) |
100 kHz |
NOTE 1: For MSR RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be Min(Prated,c,TRP – 60 dB, -16 dBm)/100 kHz. NOTE 2: For MSR multi band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requriement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or RF Bandwidth on each side of the Inter RF Bandwidth gap. |
Table 9.7.5.2.2-3: MR BS OBUE in BC1 bands applicable for: BS with maximum output power Prated,c,TRP ≤ 40 dBm and not supporting NR
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 4) |
0 MHz ≤ Δf < 0.6 MHz |
0.015MHz ≤ f_offset < 0.615MHz |
30 kHz |
|
0.6 MHz ≤ Δf < 1 MHz |
0.615MHz ≤ f_offset < 1.015MHz |
|
30 kHz |
(NOTE 3) |
1.015MHz ≤ f_offset < 1.5 MHz |
-25 dBm |
30 kHz |
1 MHz ≤ Δf ≤ 5 MHz |
1.5 MHz ≤ f_offset < 5.5 MHz |
-12 dBm |
1 MHz |
5 MHz ≤ Δf ≤ Δfmax |
5.5 MHz ≤ f_offset < f_offsetmax |
-16 dBm |
1 MHz |
NOTE 1: For MSR RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10MHz from both adjacent sub-blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -16 dBm/MHz. NOTE 2: For MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. |
Table 9.7.5.2.2-3a: MR BS OBUE in BC1 bands applicable for: BS with maximum output power Prated,c,TRP ≤ 40 dBm, supporting NR and not supporting UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (Note 1, 2) |
Measurement bandwidth (Note 4) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
-13 dBm – 7/5(f_offset/MHz – 0.05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-20 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-20 dBm (Note 4) |
100 kHz |
NOTE 1: For MSR RIB supporting non-contiguous spectrum operation within any operating band the minimum requriement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap . Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -20 dBm/100 kHz. NOTE 2: For MSR multi band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or RF Bandwidth on each side of the Inter RF Bandwidth gap. |
Table 9.7.5.2.2-4: LA BS OBUE in BC1 bands
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 4) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
100 kHz |
|
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-28 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-28 dBm (NOTE 5) |
100 kHz |
NOTE 1: For MSR RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -28dBm/100 kHz. NOTE 2: For MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. |
NOTE 3: This frequency range ensures that the range of values of f_offset is continuous.
NOTE 4: As a general rule for the requirements in the present subclause, the resolution bandwidth of the measuring equipment should be equal to the measurement bandwidth. However, to improve measurement accuracy, sensitivity and efficiency, the resolution bandwidth may be smaller than the measurement bandwidth. When the resolution bandwidth is smaller than the measurement bandwidth, the result should be integrated over the measurement bandwidth in order to obtain the equivalent noise bandwidth of the measurement bandwidth.
NOTE 5: The requirement is not applicable when Δfmax < 10 MHz.
9.7.5.2.3 Minimum requirement for Band Category 2
For an MSR RIB operating in BC2 bands, the minimum requirements are specified in tables 9.7.5.2.3-1 to 9.7.5.2.3-8.
Applicability of Wide Area operating band unwanted emission requirements in tables 9.7.5.2.3-1, 9.7.5.2.3-1a and 9.7.5.2.3-1b is specified in table 9.7.5.2.3-0.
Table 9.7.5.2.3-0: Applicability of operating band unwanted emission requirements for BC2 Wide Area BS
NR band operation |
UTRA supported |
Applicable requirement table |
None |
Y/N |
9.7.5.2.3-1 (option 2) |
In certain regions (NOTE 2), bands 3, 8 |
N |
9.7.5.2.3-1 (option 2) |
Any below 1 GHz except for certain regions (NOTE 2), band 8 |
N |
9.7.5.2.3-1a (option 1) |
Any above 1 GHz except for certain regions (NOTE 2), band 3 |
N |
9.7.5.2.3-1b (option 1) |
NOTE 1: Void. NOTE 2: Applicable only for operation in regions where Category B limits as defined in ITU-R Recommendation SM.329 [14] are used for which category B option 2 operating band unwanted emissions requirements as defined in TS 36.104 [8] and TS 38.104 [27] are applied. |
Table 9.7.5.2.3-1: WA BS OBUE in BC2 bands applicable for: BS not supporting NR; or BS supporting NR in Band n3 or n8
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 2, 3) |
Measurement bandwidth (NOTE 10) |
0 MHz ≤ Δf < 0.2 MHz (NOTE 1) |
0.015 MHz ≤ f_offset < 0.215 MHz |
-5 dBm |
30 kHz |
0.2 MHz ≤ Δf < 1 MHz |
0.215 MHz ≤ f_offset < 1.015 MHz |
30 kHz |
|
(NOTE 9) |
1.015 MHz ≤ f_offset < 1.5 MHz |
-17 dBm |
30 kHz |
1 MHz ≤ Δf ≤ min(Δfmax, 10 MHz) |
1.5 MHz ≤ f_offset < min(f_offsetmax, 10.5 MHz) |
-4 dBm |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm (NOTE 11) |
1 MHz |
NOTE 1: For operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge, the limits in table 9.7.5.2.3-2 apply for 0 MHz ≤ Δf < 0.15 MHz. NOTE 2: For MSR RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks on each side of the sub-block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10MHz from both adjacent sub-blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -6dBm/MHz. NOTE 3: For a MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE operation the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. |
Table 9.7.5.2.3-1a: WA BS OBUE in BC2 bands ≤ 1 GHz applicable for: BS supporting NR, not operating in band n8, and not supporting UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (Note 1, 2) |
Measurement bandwidth (Note 10) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
2 dBm – 7/5(f_offset/MHz – 0.05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-5 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-7 dBm (Note 11) |
100 kHz |
NOTE 1: For MSR RIB supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -7 dBm/100 kHz. NOTE 2: For MSR multi band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 3: For operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge, the limits in table 9.7.5.2.3-2 apply for 0 MHz ≤ Δf < 0.15 MHz. |
Table 9.7.5.2.3-1b: WA BS OBUE in BC2 bands > 1 GHz applicable for: BS supporting NR, not operating in band n3, and not supporting UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (Note 1, 2) |
Measurement bandwidth (Note 10) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
2 dBm – 7/5(f_offset/MHz – 0.05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-5 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-7 dBm (Note 11) |
1MHz |
NOTE 1: For MSR RIBs supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -7dBm/1MHz. NOTE 2: For MSR multi band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or RF Bandwidth. NOTE 3: For operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge, the limits in table 9.7.5.2.3-2 apply for 0 MHz ≤ Δf < 0.15 MHz. |
Table 9.7.5.2.3-2: WA BS OBUE in BC2 bands applicable for: BS operating with E-UTRA 1.4 or 3 MHz carriers adjacent to the Base Station RF Bandwidth edge
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 2, 3) |
Measurement bandwidth (NOTE 10) |
0 MHz ≤ Δf < 0.05 MHz |
0.015 MHz ≤ f_offset < 0.065 MHz |
30 kHz |
|
0.05 MHz ≤ Δf < 0.15 MHz |
0.065 MHz ≤ f_offset < 0.165 MHz |
30 kHz |
|
NOTE 1: The limits in this table only apply for operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge. NOTE 2: For MSR RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. NOTE 3: For a MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 4: (Void) |
Table 9.7.5.2.3-3: MR BS OBUE in BC2 bands applicable for: BS with maximum output power 40 < Prated,c,TRP ≤ 47 dBm and not supporting NR
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 2, 3) |
Measurement bandwidth (NOTE 10) |
0 MHz ≤ Δf < 0.6 MHz (NOTE 1) |
0.015MHz ≤ f_offset < 0.615MHz |
Prated,c,TRP-58dB-(5/3)*(f_offset-0,015)dB |
30 kHz |
0.6 MHz ≤ Δf < 1 MHz |
0.615MHz ≤ f_offset < 1.015MHz |
Prated,c,TRP-53dB-15*(f_offset-0,215)dB |
30 kHz |
(NOTE 9) |
1.015MHz ≤ f_offset < 1.5 MHz |
Prated,c,TRP – 65 dB |
30 kHz |
1 MHz ≤ Δf ≤ 2.8 MHz |
1.5 MHz ≤ f_offset < 3.3 MHz |
Prated,c,TRP – 52 dB |
1 MHz |
2.8 MHz ≤ Δf ≤ 5 MHz |
3.3 MHz ≤ f_offset < 5.5 MHz |
Prated,c,TRP – 52 dB, -6dBm) |
1 MHz |
5 MHz ≤ Δf ≤ Δfmax |
5.5 MHz ≤ f_offset < f_offsetmax |
Prated,c,TRP – 56 dB |
1 MHz |
NOTE 1: For operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge, the limits in table 9.7.5.2.3-5 apply for 0 MHz ≤ Δf < 0.15 MHz. NOTE 2: For a MSR RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10MHz from both adjacent sub-blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be (Prated,c,TRP – 56 dB)/MHz. NOTE 3: For a MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. |
Table 9.7.5.2.3-3a: MR BS OBUE in BC2 bands applicable for: BS with maximum output power 40 < Prated,c,TRP ≤ 47 dBm, supporting NR and not supporting UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (Note 1, 2) |
Measurement bandwidth (Note 10) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
Prated,c,TRP – 53 dB – (7/5)*(f_offset-0,05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
Prated,c,TRP – 60 dB |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
Min(Prated,c,TRP – 60 dB, -16 dBm) (Note 11) |
100 kHz |
NOTE 1: For MSR RIBs supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be Min(Prated,c,TRP -60 dB, -16 dBm)/100 kHz. NOTE 2: For MSR multi band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 3: For operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge, the limits in table 9.7.5.2.3-5 apply for 0 MHz ≤ Δf < 0.15 MHz. |
Table 9.7.5.2.3-4: MR BS OBUE in BC2 bands applicable for: BS with maximum output power Prated,c,TRP ≤ 40 dBm and not supporting NR
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 2, 3) |
Measurement bandwidth (NOTE 10) |
0 MHz ≤ Δf < 0.6 MHz (NOTE 1) |
0.015MHz ≤ f_offset < 0.615MHz |
30 kHz |
|
0.6 MHz ≤ Δf < 1 MHz |
0.615MHz ≤ f_offset < 1.015MHz |
30 kHz |
|
(NOTE 9) |
1.015MHz ≤ f_offset < 1.5 MHz |
-25 dBm |
30 kHz |
1 MHz ≤ Δf ≤ 5 MHz |
1.5 MHz ≤ f_offset < 5.5 MHz |
-12 dBm |
1 MHz |
5 MHz ≤ Δf ≤ Δfmax |
5.5 MHz ≤ f_offset < f_offsetmax |
-16 dBm |
1 MHz |
NOTE 1: For operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge, the limits in table 6.6.2.2-6 apply for 0 MHz ≤ Δf < 0.15MHz. NOTE 2: For a MSR RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10MHz from both adjacent sub-blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -16dBm/MHz. NOTE 3: For a MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. |
Table 9.7.5.2.3-4a: MR BS OBUE in BC2 bands applicable for: BS maximum output power Prated,c,TRP ≤ 40 dBm, supporting NR and not supporting UTRA
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (Note 1, 2) |
Measurement bandwidth (Note 10) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
-13 dBm – 7/5(f_offset/MHz – 0.05) dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-20 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-20 dBm (Note 11) |
100 kHz |
NOTE 1: For MSR RIBs supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -20 dBm/100 kHz. NOTE 2: For MSR multi band TAB connector with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 3: For operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge, the limits in table 9.7.5.2.3-6 apply for 0 MHz ≤ Δf < 0.15 MHz. |
Table 9.7.5.2.3-5: MR BS OBUE in BC2 bands applicable for: BS with maximum output power 40 < Prated,c,TRP ≤ 47 dBm and operating with E-UTRA 1.4 or 3 MHz carriers adjacent to the Base Station RF Bandwidth edge
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 2, 3) |
Measurement bandwidth (NOTE 10) |
0 MHz ≤ Δf < 0.05 MHz |
0.015 MHz ≤ f_offset < 0.065 MHz |
Prated,c,TRP-38dB-60*(f_offset-0,015)dB |
30 kHz |
0.05 MHz ≤ Δf < 0.15 MHz |
0.065 MHz ≤ f_offset < 0.165 MHz |
Prated,c,TRP-41dB-160*(f_offset-0,065)dB |
30 kHz |
NOTE 1: The limits in this table only apply for operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge. NOTE 2: For a MSR RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. NOTE 3: For a MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. |
Table 9.7.5.2.3-6: MR BS OBUE in BC2 bands applicable for: BS with maximum output power Prated,c,TRP ≤ 40 dBm and operating E-UTRA 1.4 or 3 MHz carriers adjacent to the Base Station RF Bandwidth edge
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 2, 3) |
Measurement bandwidth (NOTE 10) |
0 MHz ≤ Δf < 0.05 MHz |
0.015 MHz ≤ f_offset < 0.065 MHz |
30 kHz |
|
0.05 MHz ≤ Δf < 0.15 MHz |
0.065 MHz ≤ f_offset < 0.165 MHz |
30 kHz |
|
NOTE 1: The limits in this table only apply for operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge. NOTE 2: For a MSR RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. NOTE 3: For a MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 4: (Void) |
Table 9.7.5.2.3-7: LA BS OBUE in BC2 bands
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 2, 3) |
Measurement bandwidth (NOTE 10) |
0 MHz ≤ Δf < 5 MHz (NOTE 1) |
0.05 MHz ≤ f_offset < 5.05 MHz |
100 kHz |
|
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-28 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-28 dBm (NOTE 11) |
100 kHz |
NOTE 1: For operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge, the limits in table 9.7.5.2.3-8 apply for 0 MHz ≤ Δf < 0.16 MHz. NOTE 2: For a MSR RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -28dBm/100 kHz. NOTE 3: For a MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. |
Table 9.7.5.2.3-8: LA BS OBUE for operation in BC2 bands applicable for: BS operating with E-UTRA 1.4 or 3 MHz carriers adjacent to the Base Station RF Bandwidth edge
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 2, 3) |
Measurement bandwidth (NOTE 10) |
0 MHz ≤ Δf < 0.05 MHz |
0.015 MHz ≤ f_offset < 0.065 MHz |
30 kHz |
|
0.05 MHz ≤ Δf < 0.16 MHz |
0.065 MHz ≤ f_offset < 0.175 MHz |
30 kHz |
|
NOTE 1: The limits in this table only apply for operation with an E-UTRA 1.4 or 3 MHz carrier adjacent to the Base Station RF Bandwidth edge. NOTE 2: For a MSR RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. NOTE 3: For a MSR multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. NOTE 4: (Void) |
The following notes are common to all subclauses in 9.7.5.2.3:
NOTE 9: This frequency range ensures that the range of values of f_offset is continuous.
NOTE 10: As a general rule for the requirements in the present subclause, the resolution bandwidth of the measuring equipment should be equal to the measurement bandwidth. However, to improve measurement accuracy, sensitivity and efficiency, the resolution bandwidth may be smaller than the measurement bandwidth. When the resolution bandwidth is smaller than the measurement bandwidth, the result should be integrated over the measurement bandwidth in order to obtain the equivalent noise bandwidth of the measurement bandwidth.
NOTE 11: The requirement is not applicable when Δfmax < 10 MHz.
NOTE 12: All limits in table 9.7.5.2.3‑1, table 9.7.5.2.3‑3, table 9.7.5.2.3‑4 and table 9.7.5.2.3‑7 are identical to the corresponding limits for Band Category 1 and 3.
9.7.5.2.4 Additional requirements
9.7.5.2.4.1 Limits in FCC Title 47
In addition to the AAS BS may have to comply with the applicable emission limits established by FCC Title 47 [8], when deployed in regions where those limits are applied, and under the conditions declared by the manufacturer.
9.7.5.2.4.2 Unsynchronized operation for BC3
In certain regions, the following requirements may apply to a TDD AAS BS operating in BC3 in the same geographic area and in the same operating band as another TDD system without synchronisation. For this case the emissions shall not exceed -52 dBm/MHz in each supported downlink operating band except in:
– The frequency range from ΔfOBUE below the lower Base Station RF Bandwidth edge to the frequency ΔfOBUE above the upper Base Station RF Bandwidth edge of each supported band.
NOTE 1: Local or regional regulations may specify another excluded frequency range, which may include frequencies where synchronised TDD systems operate.
NOTE 2: TDD base stations that are synchronized and operating in BC3 can transmit without these additional co-existence requirements.
9.7.5.2.4.3 Protection of DTT
In certain regions the following requirement may apply for protection of DTT. For an AAS BS operating in Band 20, the level of emissions in the band 470-790 MHz, measured in an 8 MHz filter bandwidth on centre frequencies Ffilter according to table 9.7.5.2.4.3-1, shall not exceed the maximum emission TRP level shown in the table. This requirement applies in the frequency range 470-790 MHz even though part of the range falls in the spurious domain.
Table 9.7.5.2.4.3-1: Declared emissions levels for protection of DTT
Case |
Measurement filter centre frequency |
Condition on BS maximum aggregate TRP / 10 MHz, PTRP_10MHz (NOTE) |
Maximum Level PTRP,N,MAX |
Measurement Bandwidth |
A: for DTT frequencies where broadcasting is protected |
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
PTRP_10MHz ≥ 59 dBm |
0 dBm |
8 MHz |
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
36 ≤ PTRP_10MHz < 59 dBm |
PTRP_10MHz – 59 dBm |
8 MHz |
|
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
PTRP_10MHz < 36 dBm |
-23 dBm |
8 MHz |
|
B: for DTT frequencies where broadcasting is subject to an intermediate level of protection |
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
PTRP_10MHz ≥ 59 dBm |
10 dBm |
8 MHz |
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
36 ≤ PTRP_10MHz < 59 dBm |
PTRP_10MHz – 49 dBm |
8 MHz |
|
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
PTRP_10MHz < 36 dBm |
-13 dBm |
8 MHz |
|
C: for DTT frequencies where broadcasting is not protected |
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
N.A. |
22 dBm |
8 MHz |
NOTE: PTRP_10MHz (dBm) is defined by the expression PTRP_10MHz = P10MHz + Gant + 6dB for UTRA and PTRP_10MHz = P10MHz + Gant + 9dB for E-UTRA, where Gant is 17 dBi |
NOTE: The regional requirement is defined in terms of EIRP (effective isotropic radiated power), which is dependent on both the BS emissions and the deployment (including antenna gain and feeder loss). The method outlined in annex B1 Indicates how the limit in table 5.2.4.3-1 demonstrates compliance to the regional requirement.
9.7.5.2.4.4 Void
Table 9.7.5.2.4.4-1: Void
9.7.5.2.4.5 Co-existence with RNSS/GPS services in North America
In regions where FCC regulation applies, requirements for protection of GPS according to FCC Order DA 20-48 applies for operation in Band 24. The following normative requirement covers the base station, to be used together with other information about the site installation to verify compliance with the requirement in FCC Order DA 20-48. The requirement applies to BS operating in Band 24 to ensure that appropriate interference protection is provided to the GPS. This requirement applies in the frequency range 1541-1650 MHz even though part of the range falls in the spurious domain.
The level of emissions in the 1541 – 1650 MHz band, measured in measurement bandwidth according to table 9.7.5.2.4.5-1 shall not exceed the maximum TRP limits indicated in the table.
Table 9.7.5.2.4.5-1: Emissions levels for protection of the 1541-1650 MHz band
Operating Band |
Frequency range (MHz) |
Emission level (dBW) (Measurement bandwidth = 1 MHz) |
Emission level (dBW) of discrete emissions of less than 700 Hz bandwidth (Measurement bandwidth = 1 kHz) |
Emission level (dBW) of discrete emissions of less than 2 kHz bandwidth (Measurement bandwidth = 1 kHz) |
24 |
1541 – 1559 |
PEIRP – 17 dBi + 9 dB |
PEIRP – 17 dBi + 9 dB |
|
1559 – 1610 |
PEIRP – 17 dBi + 9 dB |
PEIRP – 17 dBi + 9 dB |
||
1610 – 1650 |
PEIRP – 17 dBi + 9 dB |
PEIRP – 17 dBi + 9 dB |
NOTE: The regional requirements, included in FCC Order DA 20-48 are defined in terms of EIRP (effective isotropic radiated power), which is dependent on both the BS emissions at the antenna connector and the deployment (including antenna gain and feeder loss). The method outlined in annex B1 indicates how the limit in table 9.7.5.2.4.5-1 demonstrates compliance to the regional requirement. PEIRP values in table 9.7.5.2.4.5-1 are the effective isotropic power (or radiated power spectral density) set in the FCC Order DA 20-48 for the specified frequency ranges and bandwidths.
9.7.5.2.4.6 Void
Table 9.7.5.2.4.6-1: Void
9.7.5.2.4.7 Additional band 32, 50, 51, 74, 75 and 76 unwanted emissions
In certain regions, the following requirements may apply to BS operating in Band 32 within 1452-1492 MHz, in Band 75 within 1432-1517 MHz and in Band 76 within 1427-1432 MHz. The maximum level of operating band unwanted emissions, measured as EIRP, on centre frequencies f_offset with filter bandwidth, according to table 9.7.5.2.4.7-1, shall not exceed the EIRP limits indicated in the table.
For Band 32, this requirement applies in the frequency range 1452-1492 MHz when non-Mobile/Fixed Communications Network (MFCN) services are deployed in adjacent frequency ranges, while it applies also within 1427-1452 MHz and/or 1492-1517 MHz when MFCN services are deployed in such frequency ranges, even though part of the ranges falls in the spurious domain. For Band 75, this requirement applies in the frequency range 1427-1517 MHz. For Band 76, this requirement applies in the frequency range 1432-1517 MHz even though part of the range falls in the spurious domain.
omain.
Table 9.7.5.2.4.7-1: Unwanted emission limits within 1427-1517 MHz
Frequency offset of measurement filter centre frequency, f_offset |
EIRP limit [dBm] |
Measurement bandwidth |
2.5 MHz |
16.3 |
5 MHz |
7.5 MHz |
11 |
5 MHz |
12.5 MHz ≤ f_offset ≤ f_offsetmax |
9 |
5 MHz |
NOTE: For Band 32, when non-MFCN services are deployed in the adjacent bands, f_offsetmax denotes the frequency difference between the lower Base Station RF Bandwidth edge and 1454.5 MHz, and the frequency difference between the upper Base Station RF Bandwidthl edge and 1489.5 MHz for the set channel position. For Band 32, when MFCN services are deployed in the adjacent frequencies, Band 75 and Band 76, f_offsetmax denotes the frequency difference between the lower Base Station RF Bandwidth edge and 1429.5 MHz, and the frequency difference between the upper Base Station RF Bandwidth edge and 1514.5 MHz for the set channel position. |
In certain regions, the following requirement may apply to BS operating in Band 32 within 1452-1492MHz for the protection of non-MFCN services in spectrum adjacent to the frequency range 1452-1492 MHz. The maximum level of emissions, measured as EIRP, on centre frequencies Ffilter with filter bandwidth according to Table 9.7.5.2.4.7-2, shall not exceed the EIRP limits indicated in the table. This requirement applies in the frequency range 1429-1518 MHz even though part of the range falls in the spurious domain.
Table 9.7.5.2.4.7-2: Unwanted emission limits outside 1452-1492 MHz
Filter centre frequency, Ffilter |
EIRP limit [dBm] |
Measurement bandwidth |
1429.5 MHz ≤ Ffilter ≤ 1448.5 MHz |
20 |
1 MHz |
Ffilter = 1450.5 MHz |
14 |
3 MHz |
Ffilter = 1493.5 MHz |
14 |
3 MHz |
1495.5 MHz ≤ Ffilter ≤ 1517.5 MHz |
20 |
1 MHz |
In certain regions, the following requirement may apply to BS operating in Band 50 and Band 75 within 1492-1517 MHz and in Band 74 within 1492-1518 MHz. The maximum level of emissions, measured as EIRP, on centre frequencies Ffilter with filter bandwidth according to table 9.7.5.2.4.7-3, shall not exceed the EIRP limits limits indicated in the table.
Table 9.7.5.2.4.7-3: Operating band 50, 74 and 75 emission test limits above 1518 MHz
Filter centre frequency, Ffilter |
EIRP limit (dBm) |
Measurement bandwidth |
1518.5 MHz ≤ Ffilter ≤ 1519.5 MHz |
-0.8 |
1 MHz |
1520.5 MHz ≤ Ffilter ≤ 1558.5 MHz |
-30 |
1 MHz |
In certain regions, the following requirement may apply to E-UTRA BS operating in Band 50 and Band 75 within 1432-1452 MHz, and in Band 51 and Band 76. Emissions shall not exceed the maximum levels specified in table 9.7.5.2.4.7-4.
Table 9.7.5.2.4.7-4: Additional emission limits for BS operating in Band 50 and 75 within 1432-1452 MHz, and in Band 51 and 76
Filter centre frequency, Ffilter |
Maximum Level [dBm] |
Measurement Bandwidth |
Ffilter = 1413.5 MHz |
-42 |
27 MHz |
9.7.5.2.4.8 Additional requirements for band 45
In certain regions the following requirement may apply to E-UTRA BS operating in Band 45. Emissions shall not exceed the maximum levels specified in table 9.7.5.2.4.8-1.
Table 9.7.5.2.4.8-1: Emissions limits for protection of adjacent band services
Operating Band |
Filter centre frequency, Ffilter |
Maximum Level [dBm] |
Measurement Bandwidth |
45 |
Ffilter = 1467.5 |
-11 |
1 MHz |
Ffilter = 1468.5 |
-14 |
1 MHz |
|
Ffilter = 1469.5 |
-17 |
1 MHz |
|
Ffilter = 1470.5 |
-24 |
1 MHz |
|
Ffilter = 1471.5 |
-31 |
1 MHz |
|
1472.5 MHz ≤ Ffilter ≤ 1491.5 MHz |
-38 |
1 MHz |
9.7.5.2.4.9 Additional requirements for band 48
The following requirement may apply to BS operating in Band 48 in certain regions. Emissions shall not exceed the maximum levels specified in table 9.7.5.2.4.9-1.
Table 9.7.5.2.4.9-1: Additional operating band unwanted emission limits for Band 48
Channel bandwidth |
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement |
Measurement bandwidth |
All |
0 MHz ≤ Δf < 10 MHz |
0.5 MHz ≤ f_offset < 9.5 MHz |
-4 dBm |
1 MHz |
9.7.5.2.4.10 Additional requirements for band 53
The following requirement may apply to BS operating in Band 53 in certain regions. Emissions shall not exceed the maximum levels specified in table 9.7.5.2.4.10-1.
Table 9.7.5.2.4.10 -1: Additional operating band unwanted emission limits for Band 53
Channel bandwidth [MHz] |
Frequency range [MHz] |
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement |
Measurement bandwidth |
1.4, 3, 5 |
2400 – 2477.5 |
6 MHz ≤ Δf < 83.5 MHz |
6.5 MHz ≤ f_offset < 83 MHz |
-16 dBm |
1 MHz |
10 |
2400 – 2473.5 |
10 MHz ≤ Δf < 83.5 MHz |
10.5 MHz ≤ f_offset < 83 MHz |
-16 dBm |
1 MHz |
1.4, 3, 5 |
2477.5 – 2478.5 |
5 MHz ≤ Δf < 6 MHz |
5.5 MHz |
-4 dBm |
1 MHz |
10 |
2473.5 – 2478.5 |
5 MHz ≤ Δf < 10 MHz |
5.5 MHz ≤ f_offset < 9.5 MHz |
-4 dBm |
1 MHz |
All |
2478.5 – 2483.5 |
0 MHz ≤ Δf < 5 MHz |
0.5 MHz ≤ f_offset < 4.5 MHz |
-1 dBm |
1 MHz |
1.4, 3, 5 |
2495 – 2501 |
0 MHz ≤ Δf < 6 MHz |
0.5 MHz ≤ f_offset < 5.5 MHz |
-4 dBm |
1 MHz |
10 |
2495 – 2505 |
0 MHz ≤ Δf < 10 MHz |
0.5 MHz ≤ f_offset < 9.5 MHz |
-4 dBm |
1 MHz |
1.4, 3, 5 |
2501 – 2690 |
6 MHz ≤ Δf < 195 MHz |
6.5 MHz ≤ f_offset < 194.5 MHz |
-16 dBm |
1 MHz |
10 |
2505 – 2690 |
10 MHz ≤ Δf < 195 MHz |
10.5 MHz ≤ f_offset < 194.5 MHz |
-16 dBm |
1 MHz |
9.7.5.3 Minimum requirement for single RAT UTRA operation
There is no operating band unwanted emission requirement for a single RAT UTRA FDD AAS BS.
9.7.5.4 Minimum requirement for single RAT E-UTRA operation
9.7.5.4.1 General
The single RAT E-UTRA operating band unwanted emission minimum requirements are given in subclauses 9.7.5.4.2, 9.7.5.4.3, 9.7.5.4.4, 9.7.5.4.5 and 9.7.5.4.6.
For an AAS BS of Wide Area BS class, the requirements of either subclause 9.7.5.4.2 (Category A limits) or subclause 9.7.5.4.3 (Category B limits) shall apply.
For an AAS BS of Local Area BS class, the requirements of subclause 9.7.5.4.4 shall apply (Category A and B).
For an AAS BS of Medium Range BS class, the requirements in subclause 9.7.5.4.5 shall apply (Category A and B).
The application of either Category A or Category B limits shall be the same as for Transmitter spurious emissions (Mandatory Requirements) in subclause 9.7.6.
9.7.5.4.2 Minimum requirements for Wide Area BS (Category A)
For E-UTRA RIB operating in Bands 5, 6, 8, 12, 13, 14, 17, 18, 19, 26, 27, 28, 29, 31, 44, 68, 71, 72, 73, 85, 87, 88 the minimum requirements are specified in tables 9.7.5.4.2‑1 to 9.7.5.4.2-3.
Table 9.7.5.4.2-1: Wide Area BS operating band unwanted emission limits for 1.4 MHz channel bandwidth (E‑UTRA bands <1GHz) for Category A
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 1.4 MHz |
0.05 MHz ≤ f_offset < 1.45 MHz |
100 kHz |
|
1.4 MHz ≤ Δf < 2.8 MHz |
1.45 MHz ≤ f_offset < 2.85 MHz |
-2 dBm |
100 kHz |
2.8 MHz ≤ Δf ≤ Δfmax |
2.85 MHz ≤ f_offset < f_offsetmax |
-4 dBm |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -13dBm/100kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. |
Table 9.7.5.4.2-2: Wide Area BS operating band unwanted emission limits for 3 MHz channel bandwidth (E‑UTRA bands <1GHz) for Category A
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 3 MHz |
0.05 MHz ≤ f_offset < 3.05 MHz |
100 kHz |
|
3 MHz ≤ Δf < 6 MHz |
3.05 MHz ≤ f_offset < 6.05 MHz |
-6 dBm |
100 kHz |
6 MHz ≤ Δf ≤ Δfmax |
6.05 MHz ≤ f_offset < f_offsetmax |
-4 dBm |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -4dBm/100kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. |
Table 9.7.5.4.2-3: Wide Area BS operating band unwanted emission limits for 5, 10, 15 and 20 MHz channel bandwidth (E-UTRA bands <1GHz) for Category A
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
100 kHz |
|
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-5 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-4 dBm (NOTE 9) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -4dBm/100kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. |
For a E-UTRA RIB operating in Bands 1, 2, 3, 4, 7, 9, 10, 11, 21, 22, 23, 24, 25, 30, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 45, 48, 50, 65, 66, 69, 70, 74, 75, emissions shall use the minimum requirements specified in tables 9.7.5.4.2-4 to 9.7.5.4.2-6:
Table 9.7.5.4.2-4: Wide Area BS operating band unwanted emission limits for 1.4 MHz channel bandwidth (E‑UTRA bands >1GHz) for Category A
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 1.4 MHz |
0.05 MHz ≤ f_offset < 1.45 MHz |
100 kHz |
|
1.4 MHz ≤ Δf < 2.8 MHz |
1.45 MHz ≤ f_offset < 2.85 MHz |
-2 dBm |
100 kHz |
2.8 MHz ≤ Δf ≤ Δfmax |
3.3 MHz ≤ f_offset < f_offsetmax |
-4 dBm |
1MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -4dBm/1MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. |
Table 9.7.5.4.2-5: Wide Area BS operating band unwanted emission limits for 3 MHz channel bandwidth (E‑UTRA bands >1GHz) for Category A
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 3 MHz |
0.05 MHz ≤ f_offset < 3.05 MHz |
100 kHz |
|
3 MHz ≤ Δf < 6 MHz |
3.05 MHz ≤ f_offset < 6.05 MHz |
-6 dBm |
100 kHz |
6 MHz ≤ Δf ≤ Δfmax |
6.5 MHz ≤ f_offset < f_offsetmax |
-4 dBm |
1MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -4dBm/1MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. |
Table 9.7.5.4.2-6: Wide Area BS operating band unwanted emission limits for 5, 10, 15 and 20 MHz channel bandwidth (E-UTRA bands >1GHz) for Category A
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
100 kHz |
|
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-5 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-4 dBm (NOTE 7) |
1MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -4dBm/1MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. |
9.7.5.4.3 Minimum requirements for Wide Area BS (Category B)
9.7.5.4.3.1 General
For Category B Operating band unwanted emissions, there are two options for the limits that may be applied regionally. Either the limits in subclause 9.7.5.4.3.2 or subclause 9.7.5.4.3 shall be applied.
9.7.5.4.3.2 Category B requirements (Option 1)
For a E-UTRA RIB operating in Bands 5, 8, 12, 13, 14, 17, 20, 26, 27, 28, 29, 31, 44, 67, 68, 71, 72, 73, 85, 87, 88 emissions shall use the minimum requirements specified in tables 6.6.5.4.3.2-1 to 6.6.5.4.3.2-3:
Table 9.7.5.4.3.2-1: Wide Area BS operating band unwanted emission limits for 1.4 MHz channel bandwidth (E‑UTRA bands <1GHz) for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7 |
0 MHz ≤ Δf < 1.4 MHz |
0.05 MHz ≤ f_offset < 1.45 MHz |
100 kHz |
|
1.4 MHz ≤ Δf < 2.8 MHz |
1.45 MHz ≤ f_offset < 2.85 MHz |
-2 dBm |
100 kHz |
2.8 MHz ≤ Δf ≤ Δfmax |
2.85 MHz ≤ f_offset < f_offsetmax |
-7 dBm |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -7dBm/100kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. |
Table 9.7.5.4.3.2-2: Wide Area BS operating band unwanted emission limits for 3 MHz channel bandwidth (E‑UTRA bands <1GHz) for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 3 MHz |
0.05 MHz ≤ f_offset < 3.05 MHz |
100 kHz |
|
3 MHz ≤ Δf < 6 MHz |
3.05 MHz ≤ f_offset < 6.05 MHz |
-6 dBm |
100 kHz |
6 MHz ≤ Δf ≤ Δfmax |
6.05 MHz ≤ f_offset < f_offsetmax |
-7 dBm |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -7dBm/100kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. |
Table 9.7.5.4.3.2-3: Wide Area BS operating band unwanted emission limits for 5, 10, 15 and 20 MHz channel bandwidth (E-UTRA bands <1GHz) for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
100 kHz |
|
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-5 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-7 dBm (NOTE 7) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -7dBm/100kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. |
For a E-UTRA RIB operating in Bands 1, 2, 3, 4, 7, 10, 22, 25, 30, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 45, 48, 50, 65, 66, 69, 70, 75, emissions shall use the minimum requirements specified in tables 9.7.5.4.3.2-4 to 9.7.5.4.3.2-6:
Table 9.7.5.4.3.2-4: Wide Area BS operating band unwanted emission limits for 1.4 MHz channel bandwidth (E‑UTRA bands >1GHz) for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 1.4 MHz |
0.05 MHz ≤ f_offset < 1.45 MHz |
100 kHz |
|
1.4 MHz ≤ Δf < 2.8 MHz |
1.45 MHz ≤ f_offset < 2.85 MHz |
-2 dBm |
100 kHz |
2.8 MHz ≤ Δf ≤ Δfmax |
3.3 MHz ≤ f_offset < f_offsetmax |
-6 dBm |
1MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -6dBm/1MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. |
Table 9.7.5.4.3.2-5: Wide Area BS operating band unwanted emission limits for 3 MHz channel bandwidth (E‑UTRA bands >1GHz) for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 3 MHz |
0.05 MHz ≤ f_offset < 3.05 MHz |
100 kHz |
|
3 MHz ≤ Δf < 6 MHz |
3.05 MHz ≤ f_offset < 6.05 MHz |
-6 dBm |
100 kHz |
6 MHz ≤ Δf ≤ Δfmax |
6.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm |
1MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -6dBm/1MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. |
Table 9.7.5.4.3.2-6: Wide Area BS operating band unwanted emission limits for 5, 10, 15 and 20 MHz channel bandwidth (E-UTRA bands >1GHz) for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
100 kHz |
|
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-5 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm (NOTE 7) |
1MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -6dBm/1MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. |
9.7.5.4.3.3 Category B requirements (Option 2)
The limits in this subclause are intended for Europe and may be applied regionally for a RIB operating in band 1, 3, 8, 32, 33, 34 or 65.
For a RIB operating in band 1, 3, 8, 32, 33, 34 or 65, emissions shall use the minimum requirements specified in table 9.7.5.4.3.3-1 below for 5, 10, 15 and 20 MHz channel bandwidth:
Table 9.7.5.4.3.3-1: Regional Wide Area BS operating band unwanted emission limits in band 1, 3, 8, 32, 33, 34 or 65 for 5, 10, 15 and 20 MHz channel bandwidth for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 0.2 MHz |
0.015MHz ≤ f_offset < 0.215MHz |
-5 dBm |
30 kHz |
0.2 MHz ≤ Δf < 1 MHz |
0.215MHz ≤ f_offset < 1.015MHz |
30 kHz |
|
(NOTE 8) |
1.015MHz ≤ f_offset < 1.5 MHz |
-17 dBm |
30 kHz |
1 MHz ≤ Δf ≤ min( 10 MHz, Δfmax) |
1.5 MHz ≤ f_offset < min(10.5 MHz, f_offsetmax) |
-4 dBm |
1 MHz |
10 MHz ≤ Δf ≤ Δfmax |
10.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm (NOTE 7) |
1 MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -6dBm/1MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. |
For a RIB operating in band 3 or 8, emissions shall use the minimum requirements specified in table 9.7.5.4.3.3‑2 below for 3 MHz channel bandwidth:
Table 9.7.5.4.3.3-2: Regional Wide Area BS operating band unwanted emission limits in band 3 or 8 for 3 MHz channel bandwidth for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 0.05 MHz |
0.015 MHz ≤ f_offset < 0.065 MHz |
30 kHz |
|
0.05 MHz ≤ Δf < 0.15 MHz |
0. 065 MHz ≤ f_offset < 0.165 MHz |
30 kHz |
|
0.15 MHz ≤ Δf < 0.2 MHz |
0.165MHz ≤ f_offset < 0.215MHz |
-5 dBm |
30 kHz |
0.2 MHz ≤ Δf < 1 MHz |
0.215MHz ≤ f_offset < 1.015MHz |
30 kHz |
|
(NOTE 8) |
1.015MHz ≤ f_offset < 1.5 MHz |
-17 dBm |
30 kHz |
1 MHz ≤ Δf ≤ 6 MHz |
1.5 MHz ≤ f_offset < 6.5 MHz |
-4 dBm |
1 MHz |
6 MHz ≤ Δf ≤ Δfmax |
6.5 MHz ≤ f_offset < f_offsetmax |
-6 dBm |
1 MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -6dBm/1MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. |
For a RIB operating in band 3 or 8, emissions shall not use the minimum requirements specified in table 9.7.5.4.3.3‑3 below for 1.4 MHz channel bandwidth:
Table 9.7.5.4.3.3-3: Regional Wide Area BS operating band unwanted emission limits in band 3 or 8 for 1.4 MHz channel bandwidth for Category B
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 0.05 MHz |
0.015 MHz ≤ f_offset < 0.065 MHz |
30 kHz |
|
0.05 MHz ≤ Δf < 0.15 MHz |
0. 065 MHz ≤ f_offset < 0.165 MHz |
30 kHz |
|
0.15 MHz ≤ Δf < 0.2 MHz |
0.165MHz ≤ f_offset < 0.215MHz |
-5 dBm |
30 kHz |
0.2 MHz ≤ Δf < 1 MHz |
0.215MHz ≤ f_offset < 1.015MHz |
30 kHz |
|
(NOTE 8) |
1.015MHz ≤ f_offset < 1.5 MHz |
-17 dBm |
30 kHz |
1 MHz ≤ Δf ≤ 2.8 MHz |
1.5 MHz ≤ f_offset < 3.3 MHz |
-4 dBm |
1 MHz |
2.8 MHz ≤ Δf ≤ Δfmax |
3.3 MHz ≤ f_offset < f_offsetmax |
-6 dBm |
1 MHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band, the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap, where the contribution from the far-end sub-block shall be scaled according to the measurement bandwidth of the near-end sub-block. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -6dBm/1MHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap, where the contribution from the far-end sub-block or Base Station RF Bandwidth shall be scaled according to the measurement bandwidth of the near-end sub-block or Base Station RF Bandwidth. |
9.7.5.4.4 Minimum requirements for Local Area BS (Category A and B)
For Local Area BS, minimum requirements are specified in tables 9.7.5.4.4-1 to 9.7.5.4.4-3.
Table 9.7.5.4.4-1: Local Area BS operating band unwanted emission limits for 1.4 MHz channel bandwidth
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 1.4 MHz |
0.05 MHz ≤ f_offset < 1.45 MHz |
100 kHz |
|
1.4 MHz ≤ Δf < 2.8 MHz |
1.45 MHz ≤ f_offset < 2.85 MHz |
-22 dBm |
100 kHz |
2.8 MHz ≤ Δf ≤ Δfmax |
2.85 MHz ≤ f_offset < f_offsetmax |
-22 dBm |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -22dBm/100kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. |
Table 9.7.5.4.4-2: Local Area BS operating band unwanted emission limits for 3 MHz channel bandwidth
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 3 MHz |
0.05 MHz ≤ f_offset < 3.05 MHz |
100 kHz |
|
3 MHz ≤ Δf < 6 MHz |
3.05 MHz ≤ f_offset < 6.05 MHz |
-26 dBm |
100 kHz |
6 MHz ≤ Δf ≤ Δfmax |
6.05 MHz ≤ f_offset < f_offsetmax |
-26 dBm |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -26dBm/100kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. |
Table 9.7.5.4.4-3: Local Area BS operating band unwanted emission limits for 5, 10, 15 and 20 MHz channel bandwidth
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
100 kHz |
|
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-28 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-28 dBm (NOTE 7) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -28dBm/100kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. |
9.7.5.4.5 Minimum requirements for Medium Range BS (Category A and B)
For Medium Range BS, minimum requirements are specified in tables 9.7.5.4.5-1 to 9.7.5.4.5-6.
Table 9.7.5.4.5-1: Medium Range BS operating band unwanted emission limits for 1.4 MHz channel bandwidth, 40 < Prated,c,TRP ≤ 47 dBm
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 1.4 MHz |
0.05 MHz ≤ f_offset < 1.45 MHz |
Prated,c,TRP-45dB-(10/1.4)*(f_offset-0,05)dB |
100 kHz |
1.4 MHz ≤ Δf < 2.8 MHz |
1.45 MHz ≤ f_offset < 2.85 MHz |
Prated,c,TRP -55dB |
100 kHz |
2.8 MHz ≤ Δf ≤ Δfmax |
2.85 MHz ≤ f_offset < f_offsetmax |
-16dBm |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -16dBm/100kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. |
Table 9.7.5.4.5-2: Medium Range BS operating band unwanted emission limits for 1.4 MHz channel bandwidth, Prated,c,TRP ≤ 40 dBm
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 1.4 MHz |
0.05 MHz ≤ f_offset < 1.45 MHz |
100 kHz |
|
1.4 MHz ≤ Δf < 2.8 MHz |
1.45 MHz ≤ f_offset < 2.85 MHz |
-15 dBm |
100 kHz |
2.8 MHz ≤ Δf ≤ Δfmax |
2.85 MHz ≤ f_offset < f_offsetmax |
-16dBm |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -16dBm/100kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. |
Table 9.7.5.4.5-3: Medium Range BS operating band unwanted emission limits for 3 MHz channel bandwidth, 40 < Prated,c,TRP ≤ 47 dBm
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 3 MHz |
0.05 MHz ≤ f_offset < 3.05 MHz |
Prated,c,TRP-49dB-(10/3)*(f_offset-0,05)dB |
100 kHz |
3 MHz ≤ Δf < 6 MHz |
3.05 MHz ≤ f_offset < 6.05 MHz |
Prated,c,TRP –59dB |
100 kHz |
6 MHz ≤ Δf ≤ Δfmax |
6.05 MHz ≤ f_offset < f_offsetmax |
Min(Prated,c,TRP –59dB, -16dBm) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be Min(Prated,c,TRP -59dB, -16dBm)/100kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. |
Table 9.7.5.4.5-4: Medium Range BS operating band unwanted emission limits for 3 MHz channel bandwidth, Prated,c,TRP ≤ 40 dBm
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 3 MHz |
0.05 MHz ≤ f_offset < 3.05 MHz |
100 kHz |
|
3 MHz ≤ Δf < 6 MHz |
3.05 MHz ≤ f_offset < 6.05 MHz |
-19 dBm |
100 kHz |
6 MHz ≤ Δf ≤ Δfmax |
6.05 MHz ≤ f_offset < f_offsetmax |
-19 dBm |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -19dBm/100kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. |
Table 9.7.5.4.5-5: Medium Range BS operating band unwanted emission limits for 5, 10, 15 and 20 MHz channel bandwidth, 40< Prated,c,TRP ≤ 47 dBm
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
Prated,c,TRP-53dB-(7/5)*(f_offset-0,05)dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
Prated,c,TRP – 60dB |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
Min(Prated,c,TRP – 60dB, -16dBm) (NOTE 6) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be Min(Prated,c,TRP -60dB, -16dBm)/100kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. |
Table 9.7.5.4.5-6: Medium Range BS operating band unwanted emission limits for 5, 10, 15 and 20 MHz channel bandwidth, Prated,c,TRP ≤ 40 dBm
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement (NOTE 1, 2) |
Measurement bandwidth (NOTE 7) |
0 MHz ≤ Δf < 5 MHz |
0.05 MHz ≤ f_offset < 5.05 MHz |
Prated,c,TRP-13dB-(7/5)*(f_offset-0,05)dB |
100 kHz |
5 MHz ≤ Δf < min(10 MHz, Δfmax) |
5.05 MHz ≤ f_offset < min(10.05 MHz, f_offsetmax) |
-20 dBm |
100 kHz |
10 MHz ≤ Δf ≤ Δfmax |
10.05 MHz ≤ f_offset < f_offsetmax |
-20 dBm (NOTE 8) |
100 kHz |
NOTE 1: For a RIB supporting non-contiguous spectrum operation within any operating band the minimum requirement within sub-block gaps is calculated as a cumulative sum of contributions from adjacent sub blocks on each side of the sub-block gap. Exception is f ≥ 10MHz from both adjacent sub blocks on each side of the sub-block gap, where the minimum requirement within sub-block gaps shall be -20dBm/100kHz. NOTE 2: For a multi-band RIB with Inter RF Bandwidth gap < 2×ΔfOBUE the minimum requirement within the Inter RF Bandwidth gaps is calculated as a cumulative sum of contributions from adjacent sub-blocks or Base Station RF Bandwidth on each side of the Inter RF Bandwidth gap. |
9.7.5.4.6 Additional requirements
9.7.5.4.6.1 Additional operating band unwanted emission limits for E-UTRA bands
These requirements may be applied for the protection of other systems operating inside or near each supported E-UTRA, E-UTRA with NB-IoT and NB-IoT BS downlink operating band. The limits may apply as an optional protection of such systems that are deployed in the same geographical area as the E-UTRA BS, or they may be set by local or regional regulation as a mandatory requirement for an E-UTRA operating band. It is in some cases not stated in the present document whether a requirement is mandatory or under what exact circumstances that a limit applies, since this is set by local or regional regulation. An overview of regional requirements in the present document is given in subclause 4.3.
In certain regions the following requirement may apply. For E-UTRA, emissions shall not exceed the maximum levels specified in Tables 9.7.5.4.6.1-1.
Table 9.7.5.4.6.1-1: Additional operating band unwanted emission limits for E-UTRA bands <1GHz
Channel bandwidth |
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement |
Measurement bandwidth (Note 8) |
200 kHz |
0 MHz ≤ Δf < 1 MHz |
0.005 MHz ≤ f_offset < 0.995 MHz |
-6 dBm |
10 kHz |
1.4 MHz |
0 MHz ≤ Δf < 1 MHz |
0.005 MHz ≤ f_offset < 0.995 MHz |
-14 dBm |
10 kHz |
3 MHz |
0 MHz ≤ Δf < 1 MHz |
0.015 MHz ≤ f_offset < 0.985 MHz |
-13 dBm |
30 kHz |
5 MHz |
0 MHz ≤ Δf < 1 MHz |
0.015 MHz ≤ f_offset < 0.985 MHz |
-15 dBm |
30 kHz |
10 MHz |
0 MHz ≤ Δf < 1 MHz |
0.05 MHz ≤ f_offset < 0.95 MHz |
-13 dBm |
100 kHz |
15 MHz |
0 MHz ≤ Δf < 1 MHz |
0.05 MHz ≤ f_offset < 0.95 MHz |
-13 dBm |
100 kHz |
20 MHz |
0 MHz ≤ Δf < 1 MHz |
0.05 MHz ≤ f_offset < 0.95 MHz |
-13 dBm |
100 kHz |
All |
1 MHz ≤ Δf < Δfmax |
1.05 MHz ≤ f_offset < f_offsetmax |
-13 dBm |
100 kHz |
In certain regions the following requirement may apply. For E-UTRA BS operating in Bands 2, 4, 10, 23, 25, 30, 35, 36, 41, 66, 70, emissions shall not exceed the maximum levels specified in Table 9.7.5.4.6.1-2.
Table 9.7.5.4.6.1-2: Additional operating band unwanted emission limits for E-UTRA bands>1GHz
Channel bandwidth |
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement |
Measurement bandwidth (Note 8) |
1.4 MHz |
0 MHz ≤ Δf < 1 MHz |
0.005 MHz ≤ f_offset < 0.995 MHz |
-14 dBm |
10 kHz |
3 MHz |
0 MHz ≤ Δf < 1 MHz |
0.015 MHz ≤ f_offset < 0.985 MHz |
-13 dBm |
30 kHz |
5 MHz |
0 MHz ≤ Δf < 1 MHz |
0.015 MHz ≤ f_offset < 0.985 MHz |
-15 dBm |
30 kHz |
10 MHz |
0 MHz ≤ Δf < 1 MHz |
0.05 MHz ≤ f_offset < 0.95 MHz |
-13 dBm |
100 kHz |
15 MHz |
0 MHz ≤ Δf < 1 MHz |
0.05 MHz ≤ f_offset < 0.95 MHz |
-15 dBm |
100 kHz |
20 MHz |
0 MHz ≤ Δf < 1 MHz |
0.05 MHz ≤ f_offset < 0.95 MHz |
-16 dBm |
100 kHz |
All |
1 MHz ≤ Δf < Δfmax |
1.5 MHz ≤ f_offset < f_offsetmax |
-13 dBm |
1 MHz |
In certain regions the following requirement may apply. For E-UTRA BS operating in Bands 12, 13, 14, 17, 29, 71, 85 emissions shall not exceed the maximum levels specified in Table 9.7.5.4.6.1-3.
Table 9.7.5.4.6.1-3: Additional operating band unwanted emission limits for E-UTRA (bands 12, 13, 14, 17, 29, 71 and 85)
Channel bandwidth |
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement |
Measurement bandwidth (Note 8) |
All |
0 MHz ≤ Δf < 100 kHz |
0.015 MHz ≤ f_offset < 0.085 MHz |
-13 dBm |
30 kHz |
All |
100 kHz ≤ Δf < Δfmax |
150 kHz ≤ f_offset < f_offsetmax |
-13 dBm |
100 kHz |
In certain regions, the following requirements may apply to an E-UTRA, E-UTRA with NB-IoT and NB-IoT TDD BS operating in the same geographic area and in the same operating band as another E-UTRA TDD system without synchronisation. For this case the emissions shall not exceed -52 dBm/MHz in each supported downlink operating band except in:
– The frequency range from 10 MHz below the lower channel edge to the frequency 10 MHz above the upper channel edge of each supported band.
9.7.5.4.6.2 Protection of DTT
In certain regions the following requirement may apply for protection of DTT. For an AAS BS operating in Band 20, the level of emissions in the band 470-790 MHz, measured in an 8 MHz filter bandwidth on centre frequencies Ffilter according to table 9.7.5.4.6.2-1, shall not exceed the maximum emission TRP level shown in the table. This requirement applies in the frequency range 470-790 MHz even though part of the range falls in the spurious domain.
Table 9.7.5.4.6.2-1: Declared emissions levels for protection of DTT
Case |
Measurement filter centre frequency |
Condition on BS maximum aggregate TRP / 10 MHz, PTRP_10MHz (NOTE) |
Maximum Level PTRP,N,MAX |
Measurement Bandwidth |
A: for DTT frequencies where broadcasting is protected |
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
PTRP_10MHz ≥ 59 dBm |
0 dBm |
8 MHz |
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
36 ≤ PTRP_10MHz < 59 dBm |
PTRP_10MHz – 59 dBm |
8 MHz |
|
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
PTRP_10MHz < 36 dBm |
-23 dBm |
8 MHz |
|
B: for DTT frequencies where broadcasting is subject to an intermediate level of protection |
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
PTRP_10MHz ≥ 59 dBm |
10 dBm |
8 MHz |
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
36 ≤ PTRP_10MHz < 59 dBm |
PTRP_10MHz – 49 dBm |
8 MHz |
|
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
PTRP_10MHz < 36 dBm |
-13 dBm |
8 MHz |
|
C: for DTT frequencies where broadcasting is not protected |
N*8 + 306 MHz, 21 ≤ N ≤ 60 |
N.A. |
22 dBm |
8 MHz |
NOTE: PTRP_10MHz (dBm) is defined by the expression PTRP_10MHz = P10MHz + Gant + 6dB for UTRA and PTRP_10MHz = P10MHz + Gant + 9dB for E-UTRA, where Gant is 17 dBi |
NOTE: The regional requirement is defined in terms of EIRP (effective isotropic radiated power), which is dependent on both the BS emissions and the deployment (including antenna gain and feeder loss). The method outlined in annex B1 Indicates how the limit in table 9.7.5.4.6.2-1 demonstrates compliance to the regional requirement.
9.7.5.4.6.3 Co-existence with RNSS/GPS services in North America
In regions where FCC regulation applies, requirements for protection of GPS according to FCC Order DA 20-48 applies for operation in Band 24. The following normative requirement covers the base station, to be used together with other information about the site installation to verify compliance with the requirement in FCC Order DA 20-48. The requirement applies to BS operating in Band 24 to ensure that appropriate interference protection is provided to the GPS. This requirement applies in the frequency range 1541-1650 MHz even though part of the range falls in the spurious domain.
The level of emissions in the 1541 – 1650 MHz band, measured in measurement bandwidth according to table 9.7.5.4.6.3-1 shall not exceed the maximum TRP limits indicated in the table.
Table 9.7.5.4.6.3-1: Emissions levels for protection of the 1541-1650 MHz band
Operating Band |
Frequency range (MHz) |
Emission level (dBW) (Measurement bandwidth = 1 MHz) |
Emission level (dBW) of discrete emissions of less than 700 Hz bandwidth (Measurement bandwidth = 1 kHz) |
Emission level (dBW) of discrete emissions of less than 2 kHz bandwidth (Measurement bandwidth = 1 kHz) |
24 |
1541 – 1559 |
PEIRP – 17 dBi + 9 dB |
PEIRP – 17 dBi + 9 dB |
|
1559 – 1610 |
PEIRP – 17 dBi + 9 dB |
PEIRP – 17 dBi + 9 dB |
||
1610 – 1650 |
PEIRP – 17 dBi + 9 dB |
PEIRP – 17 dBi + 9 dB |
NOTE: The regional requirements, included in FCC Order DA 20-48 are defined in terms of EIRP (effective isotropic radiated power), which is dependent on both the BS emissions at the antenna connector and the deployment (including antenna gain and feeder loss). The method outlined in annex B1 indicates how the limit in table 9.7.5.4.6.3-1 demonstrates compliance to the regional requirement. PEIRP values in table 9.7.5.4.6.3-1 are the effective isotropic power (or radiated power spectral density) set in the FCC Order DA 20-48 for the specified frequency ranges and bandwidths.
9.7.5.4.6.4 Void
Table 9.7.5.4.6.4-1: Void
9.7.5.4.6.5 Additional band 32, 50, 51, 74, 75 and 76 unwanted emissions
In certain regions, the following requirements may apply to BS operating in Band 32 within 1452-1492 MHz, in Band 75 within 1432-1517 MHz and in Band 76 within 1427-1432 MHz. The level of operating band unwanted emissions, measured on centre frequencies f_offset with filter bandwidth, according to table 9.7.5.4.6.5-1, shall not exceed the maximum TRP limits indicated in the table..
For Band 32, this requirement applies in the frequency range 1452-1492 MHz when non-Mobile/Fixed Communications Network (MFCN) services are deployed in adjacent frequency ranges, while it applies also within 1427-1452 MHz and/or 1492-1517 MHz when MFCN services are deployed in such frequency ranges, even though part of the ranges falls in the spurious domain. For Band 75, this requirement applies in the frequency range 1427-1517 MHz. For Band 76, this requirement applies in the frequency range 1432-1517 MHz even though part of the range falls in the spurious domain.
Table 9.7.5.4.6.5-1: Declared operating band 32, 75 and 76 unwanted emission within 1427-1517 MHz
Frequency offset of measurement filter centre frequency, f_offset |
Declared emission level [dBm] |
Measurement bandwidth |
2.5 MHz |
PEIRP – 17 dBi + 9 dB |
5 MHz |
7.5 MHz |
PEIRP – 17 dBi + 9 dB |
5 MHz |
12.5 MHz ≤ f_offset ≤ f_offsetmax |
PEIRP – 17 dBi + 9 dB |
5 MHz |
NOTE: For Band 32, when non-MFCN services are deployed in the adjacent bands, f_offsetmax denotes the frequency difference between the lower Base Station RF Bandwidth edge and 1454.5 MHz, and the frequency difference between the upper Base Station RF Bandwidthl edge and 1489.5 MHz for the set channel position. For Band 32, when MFCN services are deployed in the adjacent frequencies, Band 75 and Band 76, f_offsetmax denotes the frequency difference between the lower Base Station RF Bandwidth edge and 1429.5 MHz, and the frequency difference between the upper Base Station RF Bandwidth edge and 1514.5 MHz for the set channel position. |
NOTE: The regional requirement is defined in terms of EIRP (effective isotropic radiated power), which is dependent on both the BS emissions at the antenna connector and the deployment (including antenna gain and feeder loss). The method outlined in annex B.1 indicates how the limit in table 9.7.5.4.6.5-1 demonstrates compliance to the regional requirement.
In certain regions, the following requirement may apply to BS operating in Band 32 within 1452-1492MHz for the protection of non-MFCN services in spectrum adjacent to the frequency range 1452-1492 MHz. The level of emissions, measured on centre frequencies Ffilter with filter bandwidth according to Table 9.7.5.4.6.5-2, shall not exceed the maximum TRP limits indicated in the table. This requirement applies in the frequency range 1429-1518MHz even though part of the range falls in the spurious domain.
Table 9.7.5.4.6.5-2: Operating band 32 declared emission outside 1452-1492 MHz
Filter centre frequency, Ffilter |
Declared emission level [dBm] |
Measurement bandwidth |
1429.5 MHz ≤ Ffilter ≤ 1448.5 MHz |
PEIRP – 17 dBi + 9 dB |
1 MHz |
Ffilter = 1450.5 MHz |
PEIRP – 17 dBi + 9 dB |
3 MHz |
Ffilter = 1493.5 MHz |
PEIRP – 17 dBi + 9 dB |
3 MHz |
1495.5 MHz ≤ Ffilter ≤ 1517.5 MHz |
PEIRP – 17 dBi + 9 dB |
1 MHz |
NOTE: The regional requirement is defined in terms of EIRP (effective isotropic radiated power), which is dependent on both the BS emissions at the antenna connector and the deployment (including antenna gain and feeder loss). The method outlined in annex B.1 indicates how the limit in table 9.7.5.4.6.5-2 demonstrates compliance to the regional requirement.
In certain regions, the following requirement may apply to BS operating in Band 50 and Band 75 within 1492-1517 MHz and in Band 74 within 1492-1518 MHz. The level of emissions, measured on centre frequencies Ffilter with filter bandwidth according to table 9.7.5.4.6.5-3, shall not exceed the maximum TRP limits indicated in the table.
Table 9.7.5.4.6.5-3: Operating band 50, 74 and 75 declared emission above 1520 MHz
Filter centre frequency, Ffilter |
Declared emission level [dBm] |
Measurement bandwidth |
1520.5 MHz ≤ Ffilter ≤ 1558.5 MHz |
PEIRP – 17 dBi + 9 dB |
1 MHz |
NOTE: The regional requirement is defined in terms of EIRP (effective isotropic radiated power), which is dependent on both the BS emissions at the antenna connector and the deployment (including antenna gain and feeder loss). The method outlined in annex B.1 indicates how the limit in table 9.7.5.4.6.5-3 demonstrates compliance to the regional requirement.
In certain regions, the following requirement may apply to E-UTRA BS operating in Band 50 and Band 75 within 1432-1452 MHz, and in Band 51 and Band 76. Emissions shall not exceed the maximum levels specified in table 9.7.5.4.6.5-4.
Table 9.7.5.4.6.5-4: Additional operating band unwanted emission limits for BS operating in Band 50 and 75 within 1432-1452 MHz, and in Band 51 and 76
Filter centre frequency, Ffilter |
Maximum Level [dBm] |
Measurement Bandwidth |
Ffilter = 1413.5 MHz |
-33 |
27 MHz |
9.7.5.4.6.6 Additional requirements for band 45
In certain regions the following requirement may apply to E-UTRA BS operating in Band 45. Emissions shall not exceed the maximum levels specified in table 9.7.5.4.6.6-1.
Table 9.7.5.4.6.6-1: Emissions limits for protection of adjacent band services
Operating Band |
Filter centre frequency, Ffilter |
Maximum Level [dBm] |
Measurement Bandwidth |
45 |
Ffilter = 1467.5 |
-11 |
1 MHz |
Ffilter = 1468.5 |
-14 |
1 MHz |
|
Ffilter = 1469.5 |
-17 |
1 MHz |
|
Ffilter = 1470.5 |
-24 |
1 MHz |
|
Ffilter = 1471.5 |
-31 |
1 MHz |
|
1472.5 MHz ≤ Ffilter ≤ 1491.5 MHz |
-38 |
1 MHz |
9.7.5.4.6.7 Additional requirements for band 48
The following requirement may apply to BS operating in Band 48 in certain regions. Emissions shall not exceed the maximum levels specified in table 9.7.5.4.6.7-1.
Table 9.7.5.4.6.7-1: Additional operating band unwanted emission limits for Band 48
Channel bandwidth |
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement |
Measurement bandwidth |
All |
0 MHz ≤ Δf < 10 MHz |
0.5 MHz ≤ f_offset < 9.5 MHz |
-4 dBm |
1 MHz |