M.1 Grid Types
38.521-23GPPNRPart 2: Range 2 StandaloneRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
Two different measurement grid types are considered:
– The constant step size grid type has the azimuth and elevation angles uniformly distributed as in the examples illustrated in Figures M.1-1 in 2D and M.1-2 in 3D.
Figure M.1-1: Distribution of measurement grid points in 2D for a constant step size grid with ==15o (266 unique measurement points)
Figure M.1-2: Distribution of measurement grid points in 3D for a constant step size grid with ==15o (266 unique measurement points)
– Constant density grid types have measurement points that are evenly distributed on the surface of the sphere with a constant density as in the example illustrated in Figures M.1-3 in 2D and M.1-4 in 3D.
Figure M.1-3: Distribution of measurement grid points in 2D for a constant density grid with 266 unique measurement points
Figure M.1-4: Distribution of measurement grid points in 3D for a constant density grid type with 266 unique measurement points