E.2 Environmental
38.101-23GPPNRPart 2: Range 2 StandaloneRelease 17TSUser Equipment (UE) radio transmission and reception
The requirements in this clause apply to all types of UE(s).
E.2.1 Temperature
All RF requirements for UEs operating in FR2 are defined over the air and can only be tested in an OTA chamber.
The UE shall fulfil all the requirements in the temperature range for extreme conditions, as defined in Table E.2.1-1, unless explicitly stated otherwise in any requirement.
Table E.2.1-1: Temperature conditions
+ 25 ⁰C ± 10 ⁰C |
For normal (room temperature) conditions with relative humidity of 25 % to 75 % |
-10°C to +55°C |
For extreme conditions |
Outside this temperature range the UE, if powered on, shall not make ineffective use of the radio frequency spectrum. In no case shall the UE exceed the transmitted levels as defined in clause 6.2 for extreme operation.
E.2.2 Voltage
Editor’s note: This requirement is incomplete. The following aspects are either missing or not yet determined:
Methodology to control the voltage in a case which a power cable is not connected to DUT is FFS since it is not agreed whether we can connect the power cable to DUT at the OTA measurement situation yet.
The UE shall fulfil all the requirements in the full voltage range, i.e. the voltage range between the extreme voltages.
The manufacturer shall declare the lower and higher extreme voltages and the approximate shutdown voltage. For the equipment that can be operated from one or more of the power sources listed below, the lower extreme voltage shall not be higher, and the higher extreme voltage shall not be lower than that specified below.
Table E.2.2-1: Voltage conditions
Power source |
Lower extreme voltage |
Higher extreme voltage |
Normal conditions voltage |
AC mains |
0,9 * nominal |
1,1 * nominal |
nominal |
Regulated lead acid battery |
0,9 * nominal |
1,3 * nominal |
1,1 * nominal |
Nonregulated batteries: Leclanché Lithium Mercury/nickel & cadmium |
0,85 * nominal 0,95 * nominal 0,90 * nominal |
Nominal 1,1 * Nominal |
Nominal 1,1 * Nominal Nominal |
Outside this voltage range the UE if powered on, shall not make ineffective use of the radio frequency spectrum. In no case shall the UE exceed the transmitted levels as defined in clause 6.2 for extreme operation. In particular, the UE shall inhibit all RF transmissions when the power supply voltage is below the manufacturer declared shutdown voltage.