E.2 Environmental

38.101-23GPPNRPart 2: Range 2 StandaloneRelease 17TSUser Equipment (UE) radio transmission and reception

The requirements in this clause apply to all types of UE(s).

E.2.1 Temperature

All RF requirements for UEs operating in FR2 are defined over the air and can only be tested in an OTA chamber.

The UE shall fulfil all the requirements in the temperature range for extreme conditions, as defined in Table E.2.1-1, unless explicitly stated otherwise in any requirement.

Table E.2.1-1: Temperature conditions

+ 25 ⁰C ± 10 ⁰C

For normal (room temperature) conditions with relative humidity of 25 % to 75 %

-10°C to +55°C

For extreme conditions

Outside this temperature range the UE, if powered on, shall not make ineffective use of the radio frequency spectrum. In no case shall the UE exceed the transmitted levels as defined in clause 6.2 for extreme operation.

E.2.2 Voltage

Editor’s note: This requirement is incomplete. The following aspects are either missing or not yet determined:

Methodology to control the voltage in a case which a power cable is not connected to DUT is FFS since it is not agreed whether we can connect the power cable to DUT at the OTA measurement situation yet.

The UE shall fulfil all the requirements in the full voltage range, i.e. the voltage range between the extreme voltages.

The manufacturer shall declare the lower and higher extreme voltages and the approximate shutdown voltage. For the equipment that can be operated from one or more of the power sources listed below, the lower extreme voltage shall not be higher, and the higher extreme voltage shall not be lower than that specified below.

Table E.2.2-1: Voltage conditions

Power source

Lower extreme

voltage

Higher extreme

voltage

Normal conditions

voltage

AC mains

0,9 * nominal

1,1 * nominal

nominal

Regulated lead acid battery

0,9 * nominal

1,3 * nominal

1,1 * nominal

Nonregulated batteries:

Leclanché

Lithium

Mercury/nickel & cadmium

0,85 * nominal

0,95 * nominal

0,90 * nominal

Nominal

1,1 * Nominal

Nominal

1,1 * Nominal

Nominal

Outside this voltage range the UE if powered on, shall not make ineffective use of the radio frequency spectrum. In no case shall the UE exceed the transmitted levels as defined in clause 6.2 for extreme operation. In particular, the UE shall inhibit all RF transmissions when the power supply voltage is below the manufacturer declared shutdown voltage.

E.2.3 Void