4.1 RF conformance test cases
36.521-23GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Part 2: Implementation Conformance Statement (ICS)Radio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
NOTE: To determine applicability of a test case, FGI support in combined or fdd-Add-UE-EUTRA-Capabilities or tdd-Add-UE-EUTRA-Capabilities is taken into account.
Table 4.1-1: Applicability of RF conformance test cases, ref. TS 36.521-1 [1]
Clause |
Title |
Release |
Applicability |
Tested Bands / CA-Configurations Selection |
Branch |
Additional Information |
|||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Condition |
Comments |
||||||||||||||||
Transmitter Characteristics |
|||||||||||||||||
6.2.2 |
UE Maximum Output Power |
Rel-8 |
C186 |
UE supporting E-UTRA Power Class 3 |
D01 |
FDD, TDD |
Not required to be tested in Band 41 for Power Class 2 UE |
||||||||||
6.2.2_1 |
UE Maximum Output Power for HPUE |
Rel-10 |
C39a |
UE supporting E-UTRA Power Class 1 |
D16 |
||||||||||||
C39b |
UE supporting E-UTRA Power Class 2 |
D17 |
|||||||||||||||
6.2.2A.1 |
UE Maximum Output Power for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD, TDD |
Not required to be tested in Band 41 for Power Class 2 UE |
||||||||||
6.2.2A.1_3 |
UE Maximum Output Power for CA and HPUE (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C39b |
UE supporting intraband contiguous CA and Power Class 2 |
E01 |
TDD |
|||||||||||
6.2.2A.2 |
UE Maximum Output Power for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E03 |
FDD, TDD |
|||||||||||
Rel-14 |
C305 |
UE supporting E-UTRA and eLAA |
|||||||||||||||
6.2.2A.3 |
UE Maximum Output Power for CA (intra-band non-contiguous DL CA and UL CA) |
Rel-11 |
C115 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA |
E02 |
FDD, TDD |
|||||||||||
6.2.2A.4 |
UE Maximum Output Power for CA (3UL CA) |
Rel-13 |
C19a |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E18 |
TDD |
|||||||||||
C116a |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E18 |
FDD, TDD |
||||||||||||||
6.2.2B |
UE Maximum Output Power for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA Power Class 3 and UL-MIMO |
D05 |
FDD, TDD |
|||||||||||
6.2.2B_1 |
HPUE Maximum Output Power for UL-MIMO |
Rel-10 |
C202 |
UE supporting E-UTRA Power Class 2 and UL-MIMO |
D05 |
TDD |
|||||||||||
6.2.2E |
UE Maximum Output Power for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0) |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.2.2EA |
UE Maximum Output Power for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.2.2EB |
UE Maximum Output Power for UE category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
||||||||||||
6.2.2EC |
UE Maximum Output Power for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.2.2F |
UE Maximum Output Power for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D11, D18 |
HD-FDD, TDD |
|||||||||||
6.2.2FA |
UE Maximum Output Power for category NB1 and NB2/Power Class 6 |
Rel-14 |
C325 |
UE supporting NB-IoT and Power Class 6 |
D11, D18 |
HD-FDD, TDD |
|||||||||||
6.2.2G.2 |
UE Maximum Output Power for V2X Communication / Simultaneous E-UTRA V2X sidelink and E-UTRA uplink transmission |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
6.2.2G.4.1 |
UE Maximum Output Power for V2X Communication / Power class 2 / Non-concurrent with E-UTRA uplink transmissions |
Rel14 |
C335 |
UE supporting V2X Sidelink communication and Power Class 2 |
D14 |
TDD |
|||||||||||
6.2.2_s |
UE Maximum Output Power for subslot/slot TTI |
Rel-15 |
C352 |
UE supporting E-UTRA FDD and Power Class 3 and subslot/slot TTI |
D02 |
FDD |
|||||||||||
Rel-15 |
C352a |
UE supporting E-UTRA TDD and Power Class 3 and slot TTI |
D03 |
TDD |
Not required to be tested in Band 41 for Power Class 2 UE |
||||||||||||
6.2.5 |
Configured UE transmitted Output Power |
Rel-8 |
C186 |
UE supporting E-UTRA Power Class 3 |
D01 |
FDD, TDD |
Not required to be tested in Band 41 for Power Class 2 UE |
||||||||||
6.2.5_s |
Configured UE transmitted Output Power for subslot/slot TTI |
Rel-15 |
C352 |
UE supporting E-UTRA FDD and Power Class 3 and subslot/slot TTI |
D02 |
FDD |
|||||||||||
Rel-15 |
C352a |
UE supporting E-UTRA TDD and Power Class 3 and slot TTI |
D03 |
TDD |
Not required to be tested in Band 41 for Power Class 2 UE |
||||||||||||
6.2.5_1 |
Configured UE transmitted Output Power for HPUE |
Rel-10 |
C39a |
UE supporting E-UTRA Power Class 1 |
D16 |
||||||||||||
C39b |
UE supporting E-UTRA Power Class 2 |
D17 |
|||||||||||||||
6.2.5A.1 |
Configured UE transmitted Output Power for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD, TDD |
|||||||||||
6.2.5A.3 |
Configured UE transmitted Output Power for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E03 |
FDD, TDD |
|||||||||||
6.2.5A.4 |
Configured UE transmitted Output Power for CA (intra-band non-contiguous DL CA and UL CA) |
Rel-11 |
C115 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA |
E02 |
FDD, TDD |
|||||||||||
6.2.5A.5 |
Configured UE transmitted Output Power for CA (3UL CA) |
Rel-13 |
C19a |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E18 |
TDD |
|||||||||||
C116a |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E18 |
FDD, TDD |
||||||||||||||
6.2.5B |
Configured transmitted power for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
6.2.5E |
Configured transmitted power for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0) |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.2.5EA |
Configured UE transmitted Power for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.2.5EB |
Configured UE transmitted Power for UE category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
||||||||||||
6.2.5EC |
Configured UE transmitted Power for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.2.5F |
Configured UE transmitted Output Power for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.2.5FA |
Configured UE transmitted Output Power for category NB1 and NB2/Power Class 6 |
Rel-14 |
C325 |
UE supporting NB-IoT and Power Class 6 |
D11, D18 |
HD-FDD, TDD |
|||||||||||
6.2.5G.1 |
Configured UE transmitted Output Power for V2X Communication / Non-concurrent with E-UTRA uplink transmission |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
6.2.5G.2 |
Configured UE transmitted Output Power for V2X Communication / Simultaneous E-UTRA V2X sidelink and E-UTRA uplink transmission |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
6.2.5G.3 |
Configured UE transmitted Output Power for V2X Communication / Intra-band contiguous multi-carrier operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
6.3.1 |
Void |
||||||||||||||||
6.3.2 |
Minimum Output Power |
Rel-8 |
C113 |
UE supporting E-UTRA |
D01 |
FDD, TDD |
|||||||||||
6.3.2A.1 |
Minimum Output Power for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD, TDD |
|||||||||||
6.3.2A.2 |
Minimum Output Power for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E03 |
FDD, TDD |
|||||||||||
6.3.2A.3 |
Minimum Output Power for CA (intra-band non-contiguous DL CA and UL CA) |
Rel-11 |
C115 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E02 |
FDD |
|||||||||||
6.3.2A.4 |
Minimum Output Power for CA (3UL CA) |
Rel-13 |
C19a |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E18 |
TDD |
|||||||||||
C116a |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E18 |
FDD, TDD |
||||||||||||||
6.3.2B |
Minimum Output Power for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
6.3.2E |
Minimum Output Power for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.2EA |
Minimum Output Power for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.2EB |
Minimum Output Power for UE category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
||||||||||||
6.3.2EC |
Minimum Output Power for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.2F |
Minimum Output Power for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.3.2G.1 |
Minimum output power for V2X Communication / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
6.3.2G.2 |
Minimum output power for V2X Communication / Simultaneous E-UTRA V2X sidelink and E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
6.3.2G.3 |
Minimum output power for V2X Communication / Intra-band contiguous multi-carrier operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
6.3.3 |
Transmit OFF Power |
Rel-8 |
C113 |
UE supporting E-UTRA |
D01 |
FDD, TDD |
|||||||||||
6.3.3A.1 |
Transmit OFF Power for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD, TDD |
|||||||||||
6.3.3A.2 |
UE Transmit OFF power for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E03 |
FDD, TDD |
|||||||||||
6.3.3A.3 |
Transmit OFF Power for CA (intra-band non-contiguous DL CA and UL CA) |
Rel-11 |
C115 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA |
E02 |
FDD, TDD |
|||||||||||
6.3.3B |
UE Transmit OFF power for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
6.3.3E |
UE Transmit OFF power for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.3EA |
UE Transmit OFF power for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.3EB |
UE Transmit OFF power for UE category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
||||||||||||
6.3.3EC |
UE Transmit OFF power for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.3F |
Transmit OFF power for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.3.3G.1 |
UE Transmit OFF power for V2X Communication / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
6.3.3G.2 |
UE Transmit OFF power for V2X Communication / Simultaneous E-UTRA V2X sidelink and E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
6.3.3G.3 |
UE Transmit OFF power for V2X Communication / Intra-band contiguous multi-carrier operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
6.3.4.1 |
General ON/OFF time mask |
Rel-8 |
C113 |
UE supporting E-UTRA |
D01 |
FDD, TDD |
|||||||||||
6.3.4.1_s |
General ON/OFF time mask for subslot/slot TTI |
Rel-15 |
C353 |
UE supporting E-UTRA FDD and subslot/slot TTI |
D02 |
FDD |
|||||||||||
Rel-15 |
C353a |
UE supporting E-UTRA TDD and slot TTI |
D03 |
TDD |
|||||||||||||
6.3.4.2.1 |
PRACH time mask |
Rel-8 |
C113 |
UE supporting E-UTRA |
D01 |
FDD, TDD |
|||||||||||
6.3.4.2.2 |
SRS time mask |
Rel-8 |
C113 |
UE supporting E-UTRA |
D01 |
FDD, TDD |
|||||||||||
6.3.4A.1.1 |
General ON/OFF time mask for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD, TDD |
|||||||||||
6.3.4A.1.2 |
General ON/OFF time mask for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E03 |
FDD, TDD |
|||||||||||
6.3.4A.1.3 |
General ON/OFF time mask for CA (intra-band non-contiguous DL CA and UL CA) |
Rel-11 |
C115 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA |
E02 |
FDD, TDD |
|||||||||||
6.3.4A.1.4 |
General ON/OFF time mask for CA (3UL CA) |
Rel-13 |
C19a |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E18 |
TDD |
|||||||||||
C116a |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E18 |
FDD, TDD |
||||||||||||||
6.3.4A.1.5 |
General ON/OFF time mask for CA (4UL CA) |
Rel-11 |
C334 |
UE supporting E-UTRA and 4DL CA and 4UL CA |
E20 |
TDD |
|||||||||||
6.3.4B.1 |
ON/OFF time mask for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
6.3.4C.1 |
General ON/OFF time mask for Dual Connectivity |
Rel-12 |
C224 |
UE supporting Dual Connectivity |
E03 |
FDD, TDD |
|||||||||||
6.3.4C.1_1 |
General ON/OFF time mask for asynchronous Dual Connectivity |
Rel-12 |
C225 |
UE supporting asynchronous Dual Connectivity |
E03 |
FDD, TDD |
|||||||||||
6.3.4E.1 |
General ON/OFF time mask for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.4E.2 |
Prach and SRC ON/OFF time mask for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.4EA.1 |
General ON/OFF time mask for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.4EA.2.1 |
PRACH time mask for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.4EA.2.2 |
SRS time mask for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.4EB.1 |
General ON/OFF time mask for UE category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
||||||||||||
6.3.4EB.2.1 |
PRACH time mask for UE category 1bis |
Rel13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
||||||||||||
6.3.4EB.2.2 |
SRS time mask for UE category 1bis |
Rel13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
|||||||||||||
6.3.4EC.1 |
General ON/OFF time mask for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.4EC.2.1 |
PRACH time mask for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.4EC.2.2 |
SRS time mask for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.4F.1 |
General ON/OFF time mask for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.3.4F.2 |
NPRACH time mask for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.3.4G.1 |
General ON/OFF time mask for V2X Communication / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
6.3.4G.2 |
General ON/OFF time mask for V2X Communication / Simultaneous E-UTRA V2X sidelink and E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
6.3.4G.3 |
General ON/OFF time mask for V2X Communication / Intra-band contiguous multi-carrier operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
6.3.4G.4 |
PSSS/SSSS time mask for V2X Communication / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
6.3.5.1 |
Power Control Absolute Power Tolerance |
Rel-8 |
C186 |
UE supporting E-UTRA Power Class 3 |
D01 |
FDD, TDD |
|||||||||||
6.3.5.2 |
Power Control Relative Power Tolerance |
Rel-8 |
C186 |
UE supporting E-UTRA Power Class 3 |
D01 |
FDD, TDD |
|||||||||||
6.3.5.3 |
Aggregate Power Control Tolerance |
Rel-8 |
C186 |
UE supporting E-UTRA Power Class 3 |
D01 |
FDD, TDD |
Not required to be tested in Band 41 for Power Class 2 UE |
||||||||||
6.3.5A.1.1 |
Power Control Absolute Power Tolerance for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD, TDD |
|||||||||||
6.3.5A.1.2 |
Power Control Absolute Power Tolerance for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E03 |
FDD, TDD |
6.3.5A.1.2 |
||||||||||
Rel-14 |
C305 |
UE supporting E-UTRA and eLAA |
|||||||||||||||
6.3.5A.1.3 |
Power Control Absolute Power Tolerance for CA (intra-band non-contiguous DL CA and UL CA) |
Rel-11 |
C115 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA |
E02 |
FDD, TDD |
|||||||||||
6.3.5A.1.4 |
Power Control Absolute power tolerance for CA (3UL CA) |
Rel-13 |
C19a |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E18 |
TDD |
|||||||||||
6.3.5A.1.6 |
Power control absolute power tolerance for CA (4UL CA) |
Rel-11 |
C334 |
UE supporting E-UTRA and intra-band contiguous 4DL CA and 4UL CA |
E20 |
FDD, TDD |
|||||||||||
C336 |
UE supporting E-UTRA and inter-band 4DL CA and 4UL CA |
||||||||||||||||
C116a |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E18 |
FDD, TDD |
||||||||||||||
6.3.5A.2.1 |
Power Control Relative Power Tolerance for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD, TDD |
|||||||||||
6.3.5A.2.2 |
Power Control Relative Power Tolerance for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E03 |
FDD, TDD |
|||||||||||
Rel-14 |
C305 |
UE supporting E-UTRA and eLAA |
|||||||||||||||
6.3.5A.2.3 |
Power Control Relative Power Tolerance for CA (intra-band non-contiguous DL CA and UL CA) |
Rel-11 |
C115 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA |
E02 |
FDD, TDD |
|||||||||||
6.3.5A.2.4 |
Power Control Relative power tolerance for CA (3UL CA) |
Rel-13 |
C19a |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E18 |
TDD |
|||||||||||
C116a |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E18 |
FDD, TDD |
||||||||||||||
6.3.5A.3.1 |
Aggregate Power Control Tolerance for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD, TDD |
|||||||||||
6.3.5A.3.2 |
Aggregate Power Control Tolerance for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E03 |
FDD, TDD |
|||||||||||
6.3.5A.3.3 |
Aggregate Power Control Tolerance for CA (intra-band non-contiguous DL CA and UL CA) |
Rel-11 |
C115 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA |
E02 |
FDD, TDD |
|||||||||||
6.3.5A.3.4 |
Aggregate Power Control Tolerance for CA (3UL CA) |
Rel-13 |
C19a |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E18 |
TDD |
|||||||||||
C116a |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E18 |
FDD, TDD |
||||||||||||||
6.3.5A.3.5 |
Aggregate power control tolerance for CA (4UL CA) |
Rel-11 |
C334 |
UE supporting E-UTRA and intra-band contiguous 4DL CA and 4UL CA |
E20 |
FDD, TDD |
|||||||||||
C336 |
UE supporting E-UTRA and inter-band 4DL CA and 4UL CA |
||||||||||||||||
6.3.5B.1 |
Power Control Absolute power tolerance for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
6.3.5B.2 |
Power Control Relative power tolerance for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
6.3.5B.3 |
Aggregate power control tolerance for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
6.3.5C.2 |
Power Control Relative power tolerance for Dual Connectivity |
Rel-12 |
C224 |
UE supporting Dual Connectivity |
E03 |
FDD, TDD |
|||||||||||
6.3.5C.2_1 |
Power Control Relative power tolerance for asynchronous Dual Connectivity |
Rel-12 |
C225 |
UE supporting asynchronous Dual Connectivity |
E03 |
FDD, TDD |
|||||||||||
6.3.5E.1 |
Power Control Absolute power tolerance for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.5E.2 |
Power Control Relative power tolerance for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.5E.3 |
Aggregate power control tolerance for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.5EA.1 |
Power control for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.5EA.2 |
Power Control Relative power tolerance for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.5EA.3 |
Aggregate power control tolerance for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.5EA.3_1 |
Aggregate power control tolerance for UE category M1 (CE Mode B) |
Rel-13 |
C156c |
UE supporting E-UTRA and (UE category M1 and CEModeB) |
D02 |
HD-FDD |
|||||||||||
6.3.5EB.1 |
Power Control Absolute power tolerance for UE category 1bis |
Rel13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
||||||||||||
6.3.5EB.2 |
Power Control Relative power tolerance for UE category 1bis |
Rel13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
||||||||||||
6.3.5EB.3 |
Aggregate power control tolerance for UE category 1bis |
Rel13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
||||||||||||
6.3.5EC.1 |
Power Control Absolute power tolerance for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.5EC.2 |
Power Control Relative power tolerance for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.5EC.3 |
Aggregate power control tolerance for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.3.5EC.3_1 |
Aggregate power control tolerance for UE category M2 (CE Mode B) |
Rel-14 |
C156j |
UE supporting E-UTRA FDD and (UE category M2 and CEModeB) |
D02 |
HD-FDD |
|||||||||||
6.3.5F.1 |
Power Control Absolute power tolerance for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.3.5F.2 |
Power Control Relative power tolerance for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.3.5F.3 |
Aggregate power control tolerance for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.3.5FA.1 |
Power Control Absolute power tolerance for category NB1 and NB2/Power Class6 |
Rel-14 |
C325 |
UE supporting NB-IoT and Power Class 6 |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.3.5FA.2 |
Power Control Relative power tolerance for category NB1 and NB2/Power Class 6 |
Rel-14 |
C325 |
UE supporting NB-IoT and Power Class 6 |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.3.5FA.3 |
Aggregate power control tolerance for category NB1 and NB2/Power Class 6 |
Rel-14 |
C325 |
UE supporting NB-IoT and Power Class 6 |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.3.5_1.1 |
Power Control Absolute Power Tolerance for HPUE |
Rel-10 |
C39a |
UE supporting E-UTRA Power Class 1 |
D16 |
||||||||||||
C39b |
UE supporting E-UTRA Power Class 2 |
D17 |
|||||||||||||||
6.3.5_1.2 |
Power Control Relative Power Tolerance for HPUE |
Rel-10 |
C39a |
UE supporting E-UTRA Power Class 1 |
D16 |
||||||||||||
C39b |
UE supporting E-UTRA Power Class 2 |
D17 |
|||||||||||||||
6.3.5_1.3 |
Aggregate Power Control Tolerance for HPUE |
Rel-10 |
C39a |
UE supporting E-UTRA Power Class |
D16 |
||||||||||||
C39b |
UE supporting E-UTRA Power Class 2 |
D17 |
|||||||||||||||
6.3.5G.1 |
Power Control Absolute power tolerance for V2X Communication / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
6.3.5G.2 |
Power Control Absolute power tolerance for V2X Communication / Simultaneous E-UTRA V2X sidelink and E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
6.3.5G.3 |
Power Control Absolute power tolerance for V2X Communication / Intra-band contiguous multi-carrier operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
6.5.1 |
Frequency Error |
Rel-8 |
C113 |
UE supporting E-UTRA |
D01 |
FDD, TDD |
|||||||||||
6.5.1A.1 |
Frequency Error for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD, TDD |
|||||||||||
6.5.1A.2 |
Frequency error for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E03 |
FDD, TDD |
|||||||||||
6.5.1A.3 |
Frequency Error for CA (intra-band non-contiguous DL CA and UL CA) |
Rel-11 |
C115 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA |
E02 |
FDD, TDD |
|||||||||||
6.5.1A.4 |
Frequency error for CA (3UL CA) |
Rel-13 |
C19a |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E18 |
TDD |
|||||||||||
C116a |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E18 |
FDD, TDD |
||||||||||||||
6.5.1A.5 |
Frequency error for CA (4UL CA) |
Rel-11 |
C334 |
UE supporting E-UTRA and 4DL CA and 4UL CA |
E20 |
FDD, TDD |
|||||||||||
6.5.1B |
Frequency Error for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
6.5.1D.1 |
Frequency error for ProSe Direct Discovery |
Rel-12 |
C163 |
UE supporting E-UTRA and ProSe direct discovery |
D10 |
FDD, TDD |
|||||||||||
6.5.1D.2 |
Frequency error for ProSe Direct Communication |
Rel-12 |
C162 |
UE supporting E-UTRA and ProSe direct communication |
D10 |
FDD, TDD |
|||||||||||
6.5.1E |
Frequency Error for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.5.1EA |
Frequency Error for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.5.1EA_1 |
Frequency Error for UE category M1 (CEmodeB) |
Rel-13 |
C156c |
UE supporting E-UTRA FDD and (UE category M1 and CEModeB) |
D02 |
FDD, HD-FDD, TDD |
|||||||||||
6.5.1EB |
Frequency Error for UE category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
6.5.1EC |
Frequency Error for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.5.1EC_1 |
Frequency Error for UE category M2 (CEmodeB) |
Rel-14 |
C156j |
UE supporting E-UTRA FDD and (UE category M2 and CEModeB) |
D02 |
HD-FDD |
|||||||||||
6.5.1F |
Frequency Error for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.5.1G.1 |
Frequency Error for V2X Communication / Non-concurrent with E-UTRA uplink transmission |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
6.5.1G.2 |
Frequency error for V2X Communication / Simultaneous E-UTRA V2X sidelink and E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
6.5.2.1 |
Error Vector Magnitude (EVM) |
Rel-8 |
C113 |
UE supporting E-UTRA |
D01 |
FDD, TDD |
|||||||||||
6.5.2.1_1 |
Error Vector Magnitude (EVM) for UL 64QAM |
Rel-13 |
C147 |
UE supporting E-UTRA and UL 64QAM |
D01 |
FDD, TDD |
Note 1 |
||||||||||
6.5.2.1_2 |
Error Vector Magnitude (EVM) for UL 256QAM |
Rel-14 |
C301 |
UE supporting E-UTRA and UL 256QAM |
D01 |
FDD, TDD |
|||||||||||
6.5.2.1A |
PUSCH-EVM with exclusion period |
Rel-8 |
C113 |
UE supporting E-UTRA |
D01 |
FDD, TDD |
|||||||||||
6.5.2.1E.1 |
Error Vector Magnitude for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.5.2.1E.2 |
PUSCH-EVM with exclusion period for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.5.2.1EA.1 |
Error Vector Magnitude (EVM) for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.5.2.1EA.2 |
PUSCH-EVM with exclusion period for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.5.2.1EB |
Error Vector Magnitude (EVM) for UE category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
6.5.2.1EC.1 |
Error Vector Magnitude (EVM) for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.5.2.1EC.2 |
PUSCH-EVMwith exclusion period for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.5.2.1F.1 |
Error Vector Magnitude (EVM) for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.5.2.1G.1 |
Error Vector Magnitude (EVM) for V2X Communication / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
6.5.2.1G.2 |
Error Vector Magnitude (EVM) for V2X Communication / Simultaneous E-UTRA V2X sidelink and E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
6.5.2.1G.3 |
Error Vector Magnitude (EVM) for V2X Communication / Intra-band contiguous multi-carrier operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
6.5.2.1_s |
Error Vector Magnitude for subslot/slot TTI |
Rel-15 |
C353 |
UE supporting E-UTRA FDD and subslot/slot TTI |
D02 |
FDD |
|||||||||||
Rel-15 |
C353a |
UE supporting E-UTRA TDD and slot TTI |
D03 |
TDD |
|||||||||||||
6.5.2.2 |
Carrier leakage |
Rel-8 |
C113 |
UE supporting E-UTRA |
D01 |
FDD, TDD |
|||||||||||
6.5.2.2E |
Carrier leakage for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.5.2.2EA |
Carrier leakage for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.5.2.2EB |
Carrier leakage for UE category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
6.5.2.2EC |
Carrier leakage for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.5.2.2F |
Carrier leakage for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.5.2.2G.1 |
Carrier leakage for V2X Communication / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
6.5.2.2G.2 |
Carrier leakage for V2X Communication / Simultaneous E-UTRA V2X sidelink and E-UTRA uplink transmission |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
6.5.2.2G.3 |
Carrier leakage for V2X Communication / Intra-band contiguous MCC operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
6.5.2.3 |
In-band emissions for non allocated RB |
Rel-8 |
C113 |
UE supporting E-UTRA |
D01 |
FDD, TDD |
|||||||||||
6.5.2.3E |
In-band emissions for non allocated RB for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.5.2.3EA |
In-band emissions for non allocated RB for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.5.2.3EB |
In-band emissions for non allocated RB for UE category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
6.5.2.3EC |
In-band emissions for non allocated RB for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.5.2.3F |
In-band emissions for non allocated RB for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.5.2.3G.1 |
In-band emissions for non-allocated RB for V2X Communication / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
6.5.2.3G.2 |
Introduction of In-band emissions for non-allocated RB for V2X Communication / Simultaneous E-UTRA V2X sidelink and E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
6.5.2.3G.3 |
In-band emissions for non-allocated RB for V2X Communication / Intra-band contiguous MCC operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
6.5.2.4 |
EVM equalizer spectrum flatness |
Rel-8 |
C113 |
UE supporting E-UTRA |
D01 |
FDD, TDD |
|||||||||||
6.5.2.4E |
EVM equalizer spectrum flatness for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.5.2.4EA |
EVM equalizer spectrum flatness for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.5.2.4EB |
EVM equalizer spectrum flatness for UE category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
6.5.2.4EC |
EVM equalizer spectrum flatness for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.5.2.4G.1 |
Spectrum Emission Mask for V2X Communication / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
6.5.2.4G.3 |
EVM equalizer spectrum flatness for V2X Communication / Intra-band contiguous multi-carrier operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
6.5.2A.1.1 |
Error Vector Magnitude (EVM) for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD, TDD |
|||||||||||
6.5.2A.1.1_1 |
EVM for CA (intra-band contiguous DL CA and UL CA) with UL 64QAM |
Rel-13 |
C148 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA and UL 64QAM. |
E01 |
FDD, TDD |
Note 1 |
||||||||||
6.5.2A.1.1_2 |
EVM for CA (intra-band contiguous DL CA and UL CA) with UL 256QAM |
Rel-14 |
C302 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA and UL 256QAM. |
E01 |
FDD, TDD |
|||||||||||
6.5.2A.1.2 |
Error Vector Magnitude (EVM) for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E03 |
FDD, TDD |
|||||||||||
6.5.2A.1.2_1 |
Error Vector Magnitude (EVM) for CA (inter-band DL CA and UL CA) for UL 64QAM |
Rel-13 |
C160 |
UE supporting E-UTRA and inter-band DL CA and UL CA and UL 64QAM |
E03 |
FDD, TDD |
Note 1 |
||||||||||
6.5.2A.1.2_2 |
Error Vector Magnitude (EVM) for CA (inter-band DL CA and UL CA) for UL 256QAM |
Rel-14 |
C303 |
UE supporting E-UTRA and inter-band DL CA and UL CA and UL 256QAM. |
E03 |
FDD, TDD |
|||||||||||
6.5.2A.1.3 |
Error Vector Magnitude (EVM) for CA (intra-band non-contiguous DL CA and UL CA) |
Rel-11 |
C115 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA |
E02 |
FDD, TDD |
|||||||||||
6.5.2A.1.3_1 |
Error Vector Magnitude (EVM) for CA (intra-band non-contiguous DL CA and UL CA) for UL 64QAM |
Rel-13 |
C185 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA and UL 64QAM |
E02 |
FDD, TDD |
|||||||||||
6.5.2A.1.3_2 |
Error Vector Magnitude (EVM) for CA (intra-band non-contiguous DL CA and UL CA) for UL 256QAM |
Rel-14 |
C304 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA and UL 256QAM |
E02 |
FDD, TDD |
|||||||||||
6.5.2A.1.4 |
Error Vector Magnitude (EVM) for CA (3UL CA) |
Rel-13 |
C19a |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E18 |
TDD |
|||||||||||
C116a |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E18 |
FDD, TDD |
||||||||||||||
6.5.2A.1.5 |
Error Vector Magnitude (EVM) for CA (4UL CA) |
Rel-11 |
C334 |
UE supporting E-UTRA and 4DL CA and 4UL CA |
E20 |
FDD, TDD |
|||||||||||
6.5.2A.2.1 |
Carrier leakage for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD, TDD |
|||||||||||
6.5.2A.2.2 |
Carrier leakage for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E03 |
FDD, TDD |
|||||||||||
6.5.2A.2.4 |
Carrier leakage for CA (3UL CA) |
Rel-13 |
C19a |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E18 |
TDD |
|||||||||||
C116a |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E18 |
FDD, TDD |
||||||||||||||
6.5.2A.2.5 |
Carrier leakage for CA (4UL CA) |
Rel-11 |
C334 |
UE supporting E-UTRA and 4DL CA and 4UL CA |
E20 |
FDD, TDD |
|||||||||||
6.5.2A.2.3 |
Carrier leakage for CA (intra-band non-contiguous DL CA and UL CA) |
Rel-11 |
C115 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA |
E02 |
FDD, TDD |
|||||||||||
6.5.2A.3.1 |
In-band emissions for non allocated RB for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD, TDD |
|||||||||||
6.5.2A.3.2 |
In-band emissions for non allocated RB for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E03 |
FDD, TDD |
|||||||||||
6.5.2A.3.4 |
In-band emissions for non allocated RB for CA (3UL CA) |
Rel-13 |
C19a |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E18 |
TDD |
|||||||||||
C116a |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E18 |
FDD, TDD |
||||||||||||||
6.5.2A.3.3 |
In-band emissions for non allocated RB for CA (intra-band non-contiguous DL CA and UL CA) |
Rel-11 |
C115 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA |
E02 |
FDD, TDD |
|||||||||||
6.5.2A.3.5 |
In-band emissions for non allocated RB for CA (4UL CA) |
Rel-11 |
C334 |
UE supporting E-UTRA and 4DL CA and 4UL CA |
E20 |
FDD, TDD |
|||||||||||
6.5.2B.1 |
Error Vector Magnitude for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
6.5.2B.2 |
Carrier leakage for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
6.5.2B.3 |
In-band emissions for non allocated RB for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
6.5.2B.4 |
EVM equalizer spectrum flatness for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
6.6.1 |
Occupied bandwidth |
Rel-8 |
C113 |
UE supporting E-UTRA |
D01 |
FDD, TDD |
|||||||||||
6.6.1A.1 |
Occupied bandwidth for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD, TDD |
|||||||||||
6.6.1A.2 |
6.6.1A.2 Occupied bandwidth for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E03 |
FDD, TDD |
|||||||||||
Rel-14 |
C305 |
UE supporting E-UTRA and eLAA |
|||||||||||||||
6.6.1A.3 |
Occupied bandwidth for CA (intra-band non-contiguous DL CA and UL CA) |
Rel-11 |
C115 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA |
E02 |
FDD, TDD |
|||||||||||
6.6.1A.4 |
Occupied bandwidth for CA (3DL CA and 3UL CA) |
Rel-13 |
C19a |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E18 |
TDD |
|||||||||||
C116a |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E18 |
FDD, TDD |
||||||||||||||
6.6.1A.5 |
Occupied bandwidth for CA (4UL CA) |
Rel-11 |
C334 |
UE supporting E-UTRA and 4DL CA and 4UL CA |
E20 |
FDD, TDD |
|||||||||||
6.6.1B |
Occupied bandwidth for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
6.6.1E |
Occupied bandwidth for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.6.1EA |
Occupied bandwidth for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.6.1EB |
Occupied bandwidth for UE category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
6.6.1EC |
Occupied bandwidth for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, TDD |
|||||||||||
6.6.1F |
Occupied bandwidth for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.6.1G.1 |
Occupied bandwidth for V2X Communication / Non-concurrent with E-UTRA uplink transmission |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
6.6.1G.2 |
Occupied bandwidth for V2X Communication / Simultaneous E-UTRA V2X sidelink and E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
6.6.1G.3 |
Occupied bandwidth for V2X Communication / Intra-band contiguous multi-carrier operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
6.6.2.1 |
Spectrum Emission Mask |
Rel-8 |
C186 |
UE supporting E-UTRA Power Class 3 |
D01 |
FDD_PC3, TDD_PC3 |
Not required to be tested in Band 41 for Power Class 2 UE |
||||||||||
Rel-10 |
C39c |
UE supporting E-UTRA Power Class 1 or Power Class 2 |
D17a |
FDD_HPUE, TDD_HPUE |
|||||||||||||
6.6.2.1_1 |
Spectrum Emission Mask for Multi-cluster PUSCH |
Rel-10 |
C100 |
UE supporting E-UTRA and Multi-Cluster PUSCH |
D07 |
FDD, TDD |
|||||||||||
6.6.2.1A.1 |
Spectrum Emission Mask for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD, TDD |
|||||||||||
6.6.2.1A.2 |
Spectrum Emission Mask for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E03 |
FDD, TDD |
|||||||||||
6.6.2.1A.3 |
Spectrum Emission Mask for CA (intra-band non-contiguous DL CA and UL CA) |
Rel-11 |
C115 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA |
E02 |
FDD, TDD |
|||||||||||
6.6.2.1A.4 |
Spectrum Emission Mask for CA (3UL) |
Rel-13 |
C19a |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E18 |
TDD |
|||||||||||
C116a |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E18 |
FDD, TDD |
||||||||||||||
6.6.2.1A.5 |
Spectrum Emission Mask for CA (4UL) |
Rel-11 |
C334 |
UE supporting E-UTRA and 4DL CA and 4UL CA |
E20 |
FDD, TDD |
|||||||||||
6.6.2.1B |
Spectrum Emission Mask for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
6.6.2.1E |
Spectrum Emission Mask for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.6.2.1EA |
Spectrum Emission Mask for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.6.2.1EB |
Spectrum Emission Mask for UE category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
6.6.2.1EC |
Spectrum Emission Mask for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.6.2.1F |
Spectrum Emission Mask for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.6.2.1G.1 |
Spectrum Emission Mask for V2X Communication Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
6.6.2.1G.2 |
Introduction of Spectrum Emission Mask for V2X Communication /Sidelink simultaneous with E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
6.6.2.1G.3 |
Spectrum Emission Mask for V2X Communication / Intra-band contiguous MCC operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
6.6.2.2 |
Additional Spectrum Emission Mask |
Rel-8 |
C186 |
UE supporting E-UTRA Power Class 3 |
D01 |
FDD_PC3, TDD_PC3 |
Not required to be tested in Band 41 for Power Class 2 UE |
||||||||||
Rel-10 |
C39c |
UE supporting E-UTRA Power Class 1 or Power Class 2 |
D17a |
FDD_HPUE, TDD_HPUE |
|||||||||||||
6.6.2.2_1 |
Additional Spectrum Emission Mask for UL 64QAM |
Rel-13 |
C147 |
UE supporting E-UTRA and UL 64QAM |
D01 |
FDD, TDD |
Note 1 |
||||||||||
6.6.2.2_2 |
Additional Spectrum Emission Mask for UL 256QAM |
Rel-14 |
C301 |
UE supporting E-UTRA and UL 256QAM |
D01 |
FDD, TDD |
|||||||||||
6.6.2.2A.1 |
Additional Spectrum Emission Mask for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C319 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD, TDD |
|||||||||||
6.6.2.2A.1_1 |
Additional Spectrum Emission Mask for CA (intra-band contiguous DL CA and UL CA) for UL 64QAM |
Rel-13 |
C326 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA and UL 64QAM. |
E01 |
FDD, TDD |
Note 1, Note 4 |
||||||||||
6.6.2.2A.1_2 |
Additional Spectrum Emission Mask for CA (intra-band contiguous DL CA and UL CA) for UL 256QAM |
Rel-14 |
C302 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA and UL 256QAM. |
E01 |
FDD, TDD |
|||||||||||
6.6.2.2A.2 |
Additional Spectrum Emission Mask for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116b |
UE supporting E-UTRA and inter-band DL CA and UL CA but do not support UL 64QAM or UL 256QAM |
E03 |
FDD, TDD |
|||||||||||
6.6.2.2A.2_1 |
Additional Spectrum Emission Mask for CA (inter-band DL CA and UL CA) for UL 64QAM |
Rel-13 |
C327 |
UE supporting E-UTRA and inter-band DL CA and UL CA and UL 64QAM |
E03 |
FDD, TDD |
Note 1, Note 4 |
||||||||||
6.6.2.2A.2_2 |
Additional Spectrum Emission Mask for CA (inter-band DL CA and UL CA) for UL 256QAM |
Rel-14 |
C303 |
UE supporting E-UTRA and inter-band DL CA and UL CA and UL 256QAM |
E03 |
FDD, TDD |
|||||||||||
6.6.2.2A.3 |
Additional Spectrum Emission Mask for CA (intra-band non-contiguous DL CA and UL CA) |
Rel-11 |
C115 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA |
E02 |
FDD, TDD |
|||||||||||
6.6.2.2A.4 |
Additional Spectrum Emission Mask for CA (3UL CA) |
Rel-13 |
C19a |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E18 |
TDD |
|||||||||||
C116a |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E18 |
FDD, TDD |
||||||||||||||
6.6.2.2A.5 |
Additional Spectrum Emission Mask for CA (4UL CA) |
Rel-11 |
C334 |
UE supporting E-UTRA and 4DL CA and 4UL CA |
E20 |
FDD, TDD |
|||||||||||
6.6.2.2B |
Additional Spectrum Emission Mask for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
6.6.2.2E |
Additional Spectrum Emission Mask for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.6.2.2EA |
Additional Spectrum Emission Mask for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.6.2.2EB |
Additional Spectrum Emission Mask for UE Category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
6.6.2.2EC |
Additional Spectrum Emission Mask for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD |
|||||||||||
6.6.2.2G.1 |
Additional Spectrum Emission Mask for V2X Communication / Non-concurrent with E-UTRA uplink transmission |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
6.6.2.2G.2 |
Additional Spectrum Emission Mask for V2X Communication / Sidelink simultaneous with E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
6.6.2.3 |
Adjacent Channel Leakage power Ratio |
Rel-8 |
C186 |
UE supporting E-UTRA Power Class 3 |
D01 |
FDD, TDD |
Not required to be tested in Band 41 for Power Class 2 UE |
||||||||||
6.6.2.3_1 |
Adjacent Channel Leakage power Ratio for HPUE |
Rel-10 |
C39a |
UE supporting E-UTRA Power Class 1 |
D16 |
||||||||||||
C39b |
UE supporting E-UTRA Power Class 2 |
D17 |
|||||||||||||||
6.6.2.3_2 |
Adjacent Channel Leakage power Ratio for Multi-Cluster PUSCH |
Rel-10 |
C159 (Note 2) |
UE supporting E-UTRA and Multi-Cluster PUSCH |
D07 |
FDD, TDD |
|||||||||||
6.6.2.3_3 |
Adjacent Channel Leakage power Ratio for UL 64QAM |
Rel-13 |
C147 |
UE supporting E-UTRA and UL 64QAM |
D01 |
FDD, TDD |
Note 1 |
||||||||||
6.6.2.3_4 |
Adjacent Channel Leakage power Ratio for Multi-Cluster PUSCH with UL 64QAM |
Rel-13 |
C149 |
UE supporting E-UTRA and Multi-Cluster PUSCH and UL 64QAM |
D07 |
FDD, TDD |
Note 1, Note 4 |
||||||||||
6.6.2.3_5 |
Adjacent Channel Leakage power Ratio for UL 256QAM |
Rel-14 |
C301 |
UE supporting E-UTRA and UL 64QAM |
D01 |
FDD, TDD |
|||||||||||
6.6.2.3_6 |
Adjacent Channel Leakage power Ratio for Multi-Cluster PUSCH with UL 256QAM |
Rel-14 |
C318 |
UE supporting E-UTRA and Multi-Cluster PUSCH and UL 256QAM |
D07 |
FDD, TDD |
|||||||||||
6.6.2.3A.1 |
Adjacent Channel Leakage power Ratio for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD, TDD |
|||||||||||
6.6.2.3A.1_1 |
Adjacent Channel Leakage power Ratio for CA (intra-band contiguous DL CA and UL CA) for UL 64QAM |
Rel-13 |
C148 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA and UL 64QAM |
E01 |
FDD, TDD |
Note 1 |
||||||||||
6.6.2.3A.1_2 |
Adjacent Channel Leakage power Ratio for CA (intra-band contiguous DL CA and UL CA) for UL 256QAM |
Rel-14 |
C302 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA and UL 256QAM |
E01 |
FDD, TDD |
|||||||||||
6.6.2.3A.1_3 |
Adjacent Channel Leakage power Ratio for CA (intra-band contiguous DL CA and UL CA) for HPUE |
Rel-10 |
C39b |
UE supporting intraband contiguous CA and Power Class 2 |
E01 |
TDD |
|||||||||||
6.6.2.3A.2 |
Adjacent Channel Leakage power Ratio for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E03 |
FDD, TDD |
|||||||||||
6.6.2.3A.2_1 |
Adjacent Channel Leakage power Ratio for CA (inter-band DL CA and UL CA) for UL 64QAM |
Rel-13 |
C160 |
UE supporting E-UTRA and inter band DL CA and UL CA and UL 64QAM |
E03 |
FDD, TDD |
Note 1 |
||||||||||
6.6.2.3A.2_2 |
Adjacent Channel Leakage power Ratio for CA (inter-band DL CA and UL CA) for UL 256QAM |
Rel-13 |
C303 |
UE supporting E-UTRA and inter band DL CA and UL CA and UL 256QAM |
E03 |
FDD, TDD |
|||||||||||
Rel-14 |
C305 |
UE supporting E-UTRA and eLAA |
|||||||||||||||
6.6.2.3A.3 |
Adjacent Channel Leakage power Ratio for CA (intra-band non-contiguous DL CA and UL CA) |
Rel-11 |
C115 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA |
E02 |
FDD, TDD |
|||||||||||
6.6.2.3A.3_1 |
Adjacent Channel Leakage power Ratio for CA (intra-band non-contiguous DL CA and UL CA) for UL 64QAM |
Rel-13 |
C161 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA and UL 64QAM |
E02 |
FDD, TDD |
Note 1 |
||||||||||
6.6.2.3A.3_2 |
Adjacent Channel Leakage power Ratio for CA (intra-band non-contiguous DL CA and UL CA) for UL 256QAM |
Rel-14 |
C304 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA and UL 256QAM |
E02 |
FDD, TDD |
|||||||||||
6.6.2.3A.4 |
Adjacent Channel Leakage power Ratio for CA (3UL CA) |
Rel-13 |
C19a |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E18 |
TDD |
|||||||||||
C116a |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E18 |
FDD, TDD |
||||||||||||||
6.6.2.3A.5 |
Adjacent Channel Leakage power Ratio for CA (4UL CA) |
Rel-11 |
C334 |
UE supporting E-UTRA and 4DL CA and 4UL CA |
E20 |
FDD, TDD |
|||||||||||
6.6.2.3B |
Adjacent Channel Leakage power Ratio for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
6.6.2.3E |
Adjacent Channel Leakage power Ratio for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.6.2.3EA |
Adjacent Channel Leakage power Ratio for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.6.2.3EB |
Adjacent Channel Leakage power Ratio for UE Category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
6.6.2.3EC |
Adjacent Channel Leakage power Ratio for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.6.2.3F |
Adjacent Channel Leakage power Ratio for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.6.2.3FA |
Adjacent Channel Leakage power Ratio for category NB1 and NB2/Power Class 6 |
Rel-14 |
C325 |
UE supporting NB-IoT and Power Class 6 |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.6.2.3G.1 |
Adjacent Channel Leakage power Ratio for V2X Communication / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
6.6.2.3G.2 |
Adjacent Channel Leakage power Ratio for V2X Communication / Simultaneous E-UTRA V2X sidelink and E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
6.6.2.3G.3 |
Adjacent Channel Leakage power Ratio for V2X Communication / Intra-band contiguous multi-carrier operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
6.6.2.4 |
Void |
||||||||||||||||
6.6.3.1 |
Transmitter Spurious emissions |
Rel-8 |
C113 |
UE supporting E-UTRA |
D01 |
FDD, TDD |
|||||||||||
6.6.3.1_1 |
Transmitter Spurious emissions for Multi-Cluster PUSCH |
Rel-10 |
C100 |
UE supporting E-UTRA and Multi-Cluster PUSCH |
D07 |
FDD, TDD |
|||||||||||
6.6.3.1A.1 |
Transmitter Spurious emissions for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD, TDD |
|||||||||||
6.6.3.1A.2 |
Transmitter Spurious emissions for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E03 |
FDD, TDD |
|||||||||||
Rel-14 |
C305 |
UE supporting E-UTRA and eLAA |
|||||||||||||||
6.6.3.1A.3 |
Transmitter Spurious emissions for CA (intra-band non-contiguous DL CA and UL CA) |
Rel-11 |
C115 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA |
E02 |
FDD, TDD |
|||||||||||
6.6.3.1A.4 |
Transmitter Spurious emissions for CA (3UL CA) |
Rel-13 |
C19a |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E18 |
TDD |
|||||||||||
C116a |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E18 |
FDD, TDD |
||||||||||||||
6.6.3.1A.5 |
Transmitter Spurious emissions for CA (4UL CA) |
Rel-11 |
C334 |
UE supporting E-UTRA and 4DL CA and 4UL CA |
E20 |
FDD, TDD |
|||||||||||
6.6.3F.1 |
Transmitter Spurious emissions for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.6.3F.2 |
Spurious emission band UE co-existence for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.6.3.2 |
Spurious emission band UE co-existence |
Rel-8 |
C113 |
UE supporting E-UTRA |
D01 |
FDD, TDD |
|||||||||||
6.6.3.2A.1 |
Spurious emission band UE co-existence for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD, TDD |
|||||||||||
6.6.3.2A.2 |
Spurious emission band UE co-existence for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E03 |
FDD, TDD |
|||||||||||
6.6.3.2A.3 |
Spurious emission band UE co-existence for CA (intra-band non-contiguous DL CA and UL CA) |
Rel-11 |
C115 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA |
E02 |
FDD, TDD |
|||||||||||
6.6.3.2A.4 |
Spurious emission band UE co-existence for CA (3UL CA) |
Rel-13 |
C19a |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E18 |
TDD |
|||||||||||
C116a |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E18 |
FDD, TDD |
||||||||||||||
6.6.3.2A.5 |
Spurious emission band UE co-existence for CA (4UL CA) |
Rel-11 |
C334 |
UE supporting E-UTRA and 4DL CA and 4UL CA |
E20 |
FDD, TDD |
|||||||||||
6.6.3.3 |
Additional spurious emissions |
Rel-8 |
C113 |
UE supporting E-UTRA |
D01 |
FDD, TDD |
|||||||||||
6.6.3.3_1 |
Additional spurious emissions for UL 64QAM |
Rel-13 |
C147 |
UE supporting E-UTRA and UL 64QAM |
D01 |
FDD, TDD |
Note 1 |
||||||||||
6.6.3.3_2 |
Additional spurious emissions for UL 256QAM |
Rel-14 |
C301 |
UE supporting E-UTRA and UL 256QAM |
D01 |
FDD, TDD |
|||||||||||
6.6.3.3A.1 |
Additional spurious emissions for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C319 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD, TDD |
|||||||||||
6.6.3.3A.1_1 |
Additional spurious emissions for CA (intra-band contiguous DL CA and UL CA) for UL 64QAM |
Rel-13 |
C326 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA and UL 64QAM |
E01 |
FDD, TDD |
Note 1, Note 4 |
||||||||||
6.6.3.3A.1_2 |
Additional spurious emissions for CA (intra-band contiguous DL CA and UL CA) for UL 256QAM |
Rel-14 |
C302 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA and UL 256QAM. |
E01 |
FDD, TDD |
|||||||||||
6.6.3.3A.2 |
Additional spurious emissions for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E03 |
FDD, TDD |
|||||||||||
Rel-14 |
C305 |
UE supporting E-UTRA and eLAA |
|||||||||||||||
6.6.3.3A.2_1 |
Additional spurious emissions for CA (inter-band DL CA and UL CA) for UL 64QAM |
Rel-13 |
C327 |
UE supporting E-UTRA and inter-band DL CA and UL CA and UL 64QAM |
E03 |
FDD, TDD |
Note 1, Note 4 |
||||||||||
6.6.3.3A.2_2 |
Additional spurious emissions for CA (inter-band DL CA and UL CA) for UL 256QAM |
Rel-14 |
C303 |
UE supporting E-UTRA and inter-band DL CA and UL CA and UL 256QAM |
E03 |
FDD, TDD |
|||||||||||
6.6.3.3A.3 |
Additional spurious emissions for CA (intra-band non-contiguous DL CA and UL CA) |
Rel-11 |
C115 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA |
E02 |
FDD, TDD |
|||||||||||
6.6.3.3A.4 |
Additional spurious emissions for CA (3UL CA) |
Rel-13 |
C19a |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E18 |
TDD |
|||||||||||
C116a |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E18 |
FDD, TDD |
||||||||||||||
6.6.3.3A.5 |
Additional spurious emissions for CA (4UL CA) |
Rel-11 |
C334 |
UE supporting E-UTRA and 4DL CA and 4UL CA |
E20 |
FDD, TDD |
|||||||||||
6.6.3B.2 |
Spurious emission band UE co-existence for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
6.6.3E.1 |
Transmitter Spurious emissions for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.6.3E.2 |
Transmitter Spurious Band UE co-existence for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.6.3E.3 |
Additional spurious emissions for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.6.3EA.1 |
Transmitter Spurious emissions for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.6.3EA.2 |
Spurious emission band UE co-existence for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.6.3EA.3 |
Additional spurious emissions for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.6.3EB.1 |
Transmitter Spurious emissions for UE category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
6.6.3EB.2 |
Spurious emission band UE co-existence for UE category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
6.6.3EB.3 |
Additional spurious emissions for UE category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
6.6.3EC.1 |
Transmitter Spurious emissions for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.6.3EC.2 |
Spurious emission band UE co-existence for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.6.3EC.3 |
Additional spurious emissions for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD |
|||||||||||
6.6.3G.1 |
Transmitter Spurious emissions for V2X Communication / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
6.6.3G.1_1 |
Spurious emission band UE co-existence for V2X Communication / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
6.6.3G.2 |
Spurious emission for V2X Communication / Sidelink simultaneous with E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
6.6.3G.2_1 |
Spurious emission band UE co-existence for V2X Communication / Sidelink simultaneous with E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
6.6.3G.3 |
Spurious emission for V2X Communication / Intra-band contiguous MCC operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
6.6.3G.3_1 |
Spurious emission band UE co-existence for V2X Communication / Intra-band contiguous MCC operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
6.7 |
Transmit intermodulation |
Rel-8 |
C113 |
UE supporting E-UTRA |
D01 |
FDD, TDD |
|||||||||||
6.7A.1 |
Transmit intermodulation for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD, TDD |
|||||||||||
6.7A.2 |
Transmit intermodulation for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E03 |
FDD, TDD |
|||||||||||
6.7A.4 |
Transmit intermodulation for CA (3DL CA and 3UL CA) |
Rel-13 |
C19a |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E18 |
TDD |
|||||||||||
C116a |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E18 |
FDD, TDD |
||||||||||||||
6.7A.5 |
Transmit intermodulation for CA (4UL CA) |
Rel-11 |
C334 |
UE supporting E-UTRA and intra-band contiguous 4DL CA and 4UL CA |
E20 |
FDD, TDD |
|||||||||||
C336 |
UE supporting E-UTRA and inter-band 4DL CA and 4UL CA |
||||||||||||||||
6.7B |
Transmit intermodulation for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
6.7E |
Transmit intermodulation for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.7EA |
Transmit intermodulation for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.7EB |
Transmit intermodulation for UE Category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
6.7EC |
Transmit intermodulation for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
6.7F |
Transmit intermodulation for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
6.7G.1 |
Transmit intermodulation for V2X Communication / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
6.7G.2 |
Transmit intermodulation for V2X Communication / Simultaneous E-UTRA V2X sidelink and E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
6.7G.3 |
Transmit intermodulation for V2X Communication / Intra-band contiguous multi-carrier operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
6.8B |
Time alignment between transmitter branches for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
Receiver Characteristics |
|||||||||||||||||
7.3 |
Reference sensitivity level |
Rel-8 |
C113 |
UE supporting E-UTRA |
D15 |
FDD, TDD |
|||||||||||
7.3_1 |
Reference sensitivity level with 4 Rx antenna ports |
Rel-10 |
C113a |
UE supporting E-UTRA with 4Rx antenna ports |
D09 |
FDD, TDD |
|||||||||||
7.3A.1 |
Reference sensitivity level for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.3A.2 |
Reference sensitivity level for CA (intra-band contiguous DL CA without UL CA) |
Rel-10 |
C20 |
UE supporting E-UTRA and intra-band contiguous DL CA |
E08 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.3A.3 |
Reference sensitivity level for CA (inter-band DL CA without UL CA) |
Rel-10 |
C21 |
UE supporting E-UTRA and inter-band DL CA |
E10 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-12 |
C146 |
UE supporting E-UTRA and 2DL CA with FDD-TDD inter-band CA |
|||||||||||||||
Rel-13 |
C207 |
UE supporting E-UTRA and 2DL CA with FDD-TDD inter-band CA under FS3 |
|||||||||||||||
Rel-13 |
C208 |
UE supporting E-UTRA and 2DL CA with TDD-TDD inter-band CA under FS3 |
|||||||||||||||
7.3A.4 |
Reference sensitivity level for CA (intra-band non-contiguous DL CA without UL CA) |
Rel-11 |
C43 |
UE supporting E-UTRA and intra-band non-contiguous DL CA |
E09 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.3A.5 |
Reference sensitivity level for 3DL CA |
Rel-10 |
C121 |
UE supporting E-UTRA and 3DL with CA configurations in Table 4.1-3 |
E19 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-11 |
C122 |
UE supporting E-UTRA and 3DL with CA configurations in Table 4.1-3 |
|||||||||||||||
Rel-12 |
C123 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 |
|||||||||||||||
Rel-13 |
C268 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 under FS3 |
|||||||||||||||
Rel-13 |
C269 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 under FS3 |
|||||||||||||||
7.3A.6 |
Reference sensitivity level for CA (inter-band DL CA and UL CA) |
Rel-11 |
C116 |
UE supporting E-UTRA and inter-band DL CA and UL CA |
E03 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.3A.7 |
Reference sensitivity level for CA (intra-band non-contiguous DL CA and UL CA) |
Rel-11 |
C115 |
UE supporting E-UTRA and intra-band non-contiguous DL CA and UL CA |
E02 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.3A.9 |
Reference sensitivity level for 4DL CA |
Rel-11 |
C187 |
UE supporting E-UTRA and 4DL with CA configurations in Table 4.1-4 |
E21 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-11 |
C211 |
UE supporting E-UTRA and 4DL with CA configurations in Table 4.1-4 |
|||||||||||||||
Rel-12 |
C188 |
UE supporting E-UTRA and 4DL CA with CA configurations in Table 4.1-4 |
|||||||||||||||
7.3A.10 |
Reference sensitivity level for 5DL CA |
Rel-11 |
C221 |
UE supporting E-UTRA and 5DL with CA configurations in Table 4.1-5 |
E15 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-12 |
C222 |
UE supporting E-UTRA and 5DL CA with CA configurations in Table 4.1-5 |
|||||||||||||||
C223 |
UE supporting E-UTRA and 5DL CA with CA configurations in Table 4.1-5 |
||||||||||||||||
7.3E |
Reference sensitivity level for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0) |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.3EA |
Reference sensitivity level for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.3EB |
Reference sensitivity level for UE category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.3EC |
Reference sensitivity level for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.3B |
Reference sensitivity level for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
7.3F.1 |
Reference sensitivity level without repetitions for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
7.3G.1 |
Reference sensitivity level for V2X Communication / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
7.3G.2 |
Reference sensitivity level for V2X Communication / Simultaneous E-UTRA V2X sidelink and E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
7.3G.3 |
Reference sensitivity level for V2X Communication / Intra-band contiguous multi-carrier operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
7.4 |
Maximum input level |
Rel-8 |
C113 |
UE supporting E-UTRA |
D15 |
FDD, TDD |
|||||||||||
7.4_1 |
Maximum input level with 4 Rx antenna ports |
Rel-10 |
C168 |
UE supporting E-UTRA with 4Rx antenna ports but not 256QAM in DL |
D09 |
FDD, TDD |
|||||||||||
7.4_H |
Maximum input level for 256QAM in DL |
Rel-12 |
C113h |
UE supporting E-UTRA and 256QAM in DL |
D01 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.4A.1 |
Maximum input level for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.4A.1_H |
Maximum input level for CA (intra-band contiguous DL CA and UL CA) for 256QAM in DL |
Rel-12 |
C19h |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA and 256QAM in DL |
E01 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
|||||||||||
7.4A.2 |
Maximum input level for CA (intra-band contiguous DL CA without UL CA) |
Rel-10 |
C20 |
UE supporting E-UTRA and intra-band contiguous DL CA |
E08 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.4A.2_H |
Maximum input level for CA (intra-band contiguous DL CA without UL CA) for 256QAM in DL |
Rel-12 |
C20h |
UE supporting E-UTRA and intra-band contiguous DL CA and 256QAM in DL |
E08 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.4A.3 |
Maximum input level for CA (inter-band DL CA without UL CA) |
Rel-10 |
C21 |
UE supporting E-UTRA and inter-band DL CA |
E10 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-12 |
C146 |
UE supporting E-UTRA and 2DL CA with FDD-TDD inter-band CA |
|||||||||||||||
Rel-13 |
C207 |
UE supporting E-UTRA and 2DL CA with FDD-TDD inter-band CA under FS3 |
|||||||||||||||
Rel-13 |
C208 |
UE supporting E-UTRA and 2DL CA with TDD-TDD inter-band CA under FS3 |
|||||||||||||||
7.4A.3_H |
Maximum input level for CA (inter-band DL CA without UL CA) for 256QAM in DL |
Rel-12 |
C21h |
UE supporting E-UTRA and inter-band DL CA and 256QAM in DL |
E10 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.4A.4 |
Maximum input level for CA (intra band non-contiguous DL CA without UL CA) |
Rel-11 |
C43 |
UE supporting E-UTRA and intra-band non-contiguous DL CA |
E09 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.4A.4_H |
Maximum input level for CA (intra band non-contiguous DL CA without UL CA) for 256QAM in DL |
Rel-12 |
C43h |
UE supporting E-UTRA and intra-band non-contiguous DL CA and 256QAM in DL |
E09 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.4A.5 |
Maximum input level for 3DL CA |
Rel-10 |
C121 |
UE supporting E-UTRA and 3DL with CA configurations in Table 4.1-3 |
E22 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-11 |
C122 |
UE supporting E-UTRA and 3DL with CA configurations in Table 4.1-3 |
|||||||||||||||
Rel-12 |
C123 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 |
|||||||||||||||
Rel-13 |
C268 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 under FS3 |
|||||||||||||||
Rel-13 |
C269 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 under FS3 |
|||||||||||||||
7.4A.5_H |
Maximum input level for 3DL CA for 256QAM in DL |
Rel-12 |
C122h |
UE supporting E-UTRA and 3DL CA and 256QAM in DL |
E22 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
Rel-13 |
C268 |
UE supporting E-UTRA and 3DL CA with FDD-TDD CA under FS3 |
|||||||||||||||
Rel-13 |
C269 |
UE supporting E-UTRA and 3DL CA with TDD-TDD CA under FS3 |
|||||||||||||||
7.4A.7 |
Maximum input level for 4DL CA |
Rel-11 |
C187 |
UE supporting E-UTRA and 4DL with CA configurations in Table 4.1-4 |
E23 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-11 |
C211 |
UE supporting E-UTRA and 4DL with CA configurations in Table 4.1-4 |
|||||||||||||||
Rel-12 |
C188 |
UE supporting E-UTRA and 4DL CA with CA configurations in Table 4.1-4 |
|||||||||||||||
7.4A.7_H |
Maximum input level for 4DL CA for 256QAM in DL |
Rel-13 |
C187h |
UE supporting E-UTRA and 4DL CA with CA configurations in Table 4.1-4 and 256QAM in DL |
E23 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
7.4A.8 |
Maximum input level for 5DL CA |
Rel-11 |
C221 |
UE supporting E-UTRA and 5DL with CA configurations in Table 4.1-5 |
E15 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-12 |
C222 |
UE supporting E-UTRA and 5DL CA with CA configurations in Table 4.1-5 |
|||||||||||||||
Rel-12 |
C223 |
UE supporting E-UTRA and 5DL CA with CA configurations in Table 4.1-5 |
|||||||||||||||
7.4A.8_H |
Maximum input level for 5DL CA for 256QAM in DL |
Rel-13 |
C221h |
UE supporting E-UTRA and 5DL with CA configurations in Table 4.1-5 and 256QAM in DL |
E15 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
7.4A.9 |
Maximum input level for 6DL CA |
Rel-14 |
C342 |
UE supporting E-UTRA and 6DL with CA configurations in Table 4.1-6 |
E26 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
7.4A.9_H |
Maximum input level for 6DL CA for 256QAM in DL |
Rel-14 |
C342h |
UE supporting E-UTRA and 6DL with CA configurations in Table 4.1-6 and 256QAM in DL |
E26 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
7.4B |
Maximum input level for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
7.4D.1 |
Maximum input level for ProSe Direct Discovery |
Rel-12 |
C163 |
UE supporting E-UTRA and ProSe direct discovery |
D10 |
FDD, TDD |
|||||||||||
7.4D.2 |
Maximum input level for ProSe Direct Communication |
Rel-12 |
C162 |
UE supporting E-UTRA and ProSe direct communication |
D10 |
FDD, TDD |
|||||||||||
7.4E |
Maximum input level for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0) |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.4EA |
Maximum input level for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.4EB |
Maximum input level for UE Category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
7.4EC |
Maximum input level for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.4F |
Maximum input level for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
7.4G.1 |
Maximum input level for V2X Communication / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
7.4G.2 |
Maximum input level for V2X Communication / Simultaneous E-UTRA V2X sidelink and E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
7.4G.3 |
Maximum input level for V2X Communication / Intra-band contiguous multi-carrier operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
7.5 |
Adjacent Channel Selectivity (ACS) |
Rel-8 |
C113 |
UE supporting E-UTRA |
D15 |
FDD, TDD |
|||||||||||
7.5_1 |
Adjacent Channel Selectivity (ACS) with 4 Rx antenna ports |
Rel-10 |
C113a |
UE supporting E-UTRA with 4Rx antenna ports |
D09 |
FDD, TDD |
|||||||||||
7.5A.1 |
Adjacent Channel Selectivity (ACS) for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.5A.2 |
Adjacent Channel Selectivity (ACS) for CA (intra-band contiguous DL CA without UL CA) |
Rel-10 |
C20 |
UE supporting E-UTRA and intra-band contiguous DL CA |
E08 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.5A.3 |
Adjacent Channel Selectivity (ACS) for CA (inter-band DL CA without UL CA) |
Rel-10 |
C21 |
UE supporting E-UTRA and inter-band DL CA |
E10 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-12 |
C146 |
UE supporting E-UTRA and 2DL CA with FDD-TDD inter-band CA |
|||||||||||||||
Rel-13 |
C207 |
UE supporting E-UTRA and 2DL CA with FDD-TDD inter-band CA under FS3 |
|||||||||||||||
Rel-13 |
C208 |
UE supporting E-UTRA and 2DL CA with TDD-TDD inter-band CA under FS3 |
|||||||||||||||
7.5A.4 |
Adjacent Channel Selectivity (ACS) for CA (intra band non-contiguous DL CA without UL CA) |
Rel-11 |
C43 |
UE supporting E-UTRA and intra-band non-contiguous DL CA |
E09 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.5A.5 |
Adjacent Channel Selectivity (ACS) for 3DL CA |
Rel-10 |
C121 |
UE supporting E-UTRA and 3DL with CA configurations in Table 4.1-3 |
E24 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-11 |
C122 |
UE supporting E-UTRA and 3DL with CA configurations in Table 4.1-3 |
|||||||||||||||
Rel-12 |
C123 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 |
|||||||||||||||
Rel-13 |
C268 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 under FS3 |
|||||||||||||||
Rel-13 |
C269 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 under FS3 |
|||||||||||||||
7.5A.7 |
Adjacent Channel Selectivity (ACS) for 4DL CA |
Rel-11 |
C187 |
UE supporting E-UTRA and 4DL with CA configurations in Table 4.1-4 |
E25 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-11 |
C211 |
UE supporting E-UTRA and 4DL with CA configurations in Table 4.1-4 |
|||||||||||||||
Rel-12 |
C188 |
UE supporting E-UTRA and 4DL CA with CA configurations in Table 4.1-4 |
|||||||||||||||
7.5A.8 |
Adjacent Channel Selectivity (ACS) for 5DL CA |
Rel-11 |
C221 |
UE supporting E-UTRA and 5DL with CA configurations in Table 4.1-5 |
E15 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-12 |
C222 |
UE supporting E-UTRA and 5DL CA with CA configurations in Table 4.1-5 |
|||||||||||||||
Rel-12 |
C223 |
UE supporting E-UTRA and 5DL CA with CA configurations in Table 4.1-5 |
|||||||||||||||
7.5A.9 |
Adjacent Channel Selectivity (ACS) for 6DL CA |
Rel-14 |
C342 |
UE supporting E-UTRA and 6DL CA with CA configurations in Table 4.1-6 |
E26 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
7.5B |
Adjacent Channel Selectivity (ACS)for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
7.5D.1 |
Adjacent Channel Selectivity (ACS) for ProSe Direct Discovery |
Rel-12 |
C163 |
UE supporting E-UTRA and ProSe direct discovery |
D10 |
FDD, TDD |
|||||||||||
7.5D.2 |
Adjacent Channel Selectivity (ACS) for ProSe Direct Communication |
Rel-12 |
C162 |
UE supporting E-UTRA and ProSe direct communication |
D10 |
FDD, TDD |
|||||||||||
7.5E |
Adjacent Channel Selectivity (ACS) for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0) |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.5EA |
Adjacent Channel Selectivity (ACS) for category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.5EB |
Adjacent Channel Selectivity (ACS) for UE Category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
7.5EC |
Adjacent Channel Selectivity (ACS)for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.5F |
Adjacent Channel Selectivity (ACS) for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
7.5G.1 |
Adjacent channel selectivity (ACS) for V2X Communication / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
7.5G.2 |
Adjacent channel selectivity (ACS) for V2X Communication / Simultaneous E-UTRA V2X sidelink and E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
7.5G.3 |
Adjacent channel selectivity (ACS) for V2X Communication / Intra-band contiguous multi-carrier operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
7.6.1 |
In-band blocking |
Rel-8 |
C113 |
UE supporting E-UTRA |
D15 |
FDD, TDD |
|||||||||||
7.6.1_1 |
In-band blocking with 4 Rx antenna ports |
Rel-10 |
C113a |
UE supporting E-UTRA with 4Rx antenna ports |
D09 |
FDD, TDD |
|||||||||||
7.6.1A.1 |
In-band blocking for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.6.1A.2 |
In-band blocking for CA (intra-band contiguous DL CA without UL CA) |
Rel-10 |
C20 |
UE supporting E-UTRA and intra-band contiguous DL CA |
E08 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.6.1A.3 |
In-band blocking for CA (inter-band DL CA without UL CA) |
Rel-10 |
C21 |
UE supporting E-UTRA and inter-band DL CA |
E10 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-12 |
C146 |
UE supporting E-UTRA and 2DL CA with FDD-TDD inter-band CA |
|||||||||||||||
Rel-13 |
C207 |
UE supporting E-UTRA and 2DL CA with FDD-TDD inter-band CA under FS3 |
|||||||||||||||
Rel-13 |
C208 |
UE supporting E-UTRA and 2DL CA with TDD-TDD inter-band CA under FS3 |
|||||||||||||||
7.6.1A.4 |
In-band blocking for CA (intra-band non-contiguous DL CA without UL CA) |
Rel-11 |
C43 |
UE supporting E-UTRA and intra-band non-contiguous DL CA |
E09 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.6.1A.5 |
In-band blocking for 3DL CA |
Rel-10 |
C121 |
UE supporting E-UTRA and 3DL with CA configurations in Table 4.1-3 |
E24 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-11 |
C122 |
UE supporting E-UTRA and 3DL with CA configurations in Table 4.1-3 |
|||||||||||||||
Rel-12 |
C123 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 |
|||||||||||||||
Rel-13 |
C268 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 under FS3 |
|||||||||||||||
Rel-13 |
C269 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3under FS3 |
|||||||||||||||
7.6.1A.7 |
In-band blocking for 4DL CA |
Rel-11 |
C187 |
UE supporting E-UTRA and 4DL with CA configurations in Table 4.1-4 |
E25 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-11 |
C211 |
UE supporting E-UTRA and 4DL with CA configurations in Table 4.1-4 |
|||||||||||||||
Rel-12 |
C188 |
UE supporting E-UTRA and 4DL CA with CA configurations in Table 4.1-4 |
|||||||||||||||
7.6.1A.8 |
In-band blocking for 5DL CA |
Rel-11 |
C221 |
UE supporting E-UTRA and 5DL with CA configurations in Table 4.1-5 |
E15 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
|||||||||||
Rel-12 |
C222 |
UE supporting E-UTRA and 5DL CA with CA configurations in Table 4.1-5 |
|||||||||||||||
Rel-12 |
C223 |
UE supporting E-UTRA and 5DL CA with CA configurations in Table 4.1-5 |
|||||||||||||||
7.6.1A.9 |
In-band blocking for 6DL CA |
Rel-14 |
C342 |
UE supporting E-UTRA and 6DL CA with CA configurations in Table 4.1-6 |
E26 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
7.6.1A.10 |
In-band blocking for 7DL CA |
Rel-14 |
C358 |
UE supporting E-UTRA FDD and TDD and 7DL CA with FDD as PCell (UE Category8, and Category 11 and onwards) |
TBD |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
7.6.1B |
In-band blocking for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
7.6.1D.1 |
In-band blocking for ProSe Direct Discovery |
Rel-12 |
C163 |
UE supporting E-UTRA and ProSe direct discovery |
D10 |
FDD, TDD |
|||||||||||
7.6.1D.2 |
In-band blocking for ProSe Direct Communication |
Rel-12 |
C162 |
UE supporting E-UTRA and ProSe direct communication |
D10 |
FDD, TDD |
|||||||||||
7.6.1E |
In-band blocking for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0) |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.6.1EA |
In-band blocking for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.6.1EB |
In-band blocking for UE Category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
7.6.1EC |
In-band blocking for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.6.1F |
In-band blocking for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
7.6.1G.1 |
In-band blocking for V2X Communication / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
7.6.1G.2 |
In-band blocking for V2X Communication / Simultaneous E-UTRA V2X sidelink and E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
7.6.1G.3 |
In-band blocking for V2X Communication / Intra-band contiguous multi-carrier operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
7.6.2 |
Out of-band blocking |
Rel-8 |
C113 |
UE supporting E-UTRA |
D15 |
FDD, TDD |
|||||||||||
7.6.2_1 |
Out of-band blocking with 4 Rx antenna ports |
Rel-10 |
C113a |
UE supporting E-UTRA with 4Rx antenna ports |
D09 |
FDD, TDD |
|||||||||||
7.6.2A.1 |
Out of-band blocking for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.6.2A.2 |
Out of-band blocking for CA (intra-band contiguous DL CA without UL CA) |
Rel-10 |
C20 |
UE supporting E-UTRA and intra-band contiguous DL CA |
E08 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.6.2A.3 |
Out of-band blocking for CA (inter-band DL CA without UL CA) |
Rel-10 |
C21 |
UE supporting E-UTRA and inter-band DL CA |
E10 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-12 |
C146 |
UE supporting E-UTRA and 2DL CA with FDD-TDD inter-band CA |
|||||||||||||||
Rel-13 |
C207 |
UE supporting E-UTRA and 2DL CA with FDD-TDD inter-band CA under FS3 |
E12 |
||||||||||||||
Rel-13 |
C208 |
UE supporting E-UTRA and 2DL CA with TDD inter-band CA under FS3 |
|||||||||||||||
7.6.2A.4 |
Out of-band blocking for CA (intra-band non-contiguous DL CA without UL CA) |
Rel-11 |
C43 |
UE supporting E-UTRA and intra-band non-contiguous DL CA |
E09 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.6.2A.5 |
Out-of-band blocking for 3DL CA |
Rel-10 |
C121 |
UE supporting E-UTRA and 3DL with CA configurations in Table 4.1-3 |
E19 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-11 |
C122 |
UE supporting E-UTRA and 3DL with CA configurations in Table 4.1-3 |
|||||||||||||||
Rel-12 |
C123 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 |
|||||||||||||||
Rel-13 |
C268 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 under FS3 |
|||||||||||||||
Rel-13 |
C269 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 under FS3 |
|||||||||||||||
7.6.2A.7 |
Out-of-band blocking for 4DL CA |
Rel-11 |
C187 |
UE supporting E-UTRA and 4DL with CA configurations in Table 4.1-4 |
E21 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-11 |
C211 |
UE supporting E-UTRA and 4DL with CA configurations in Table 4.1-4 |
|||||||||||||||
Rel-12 |
C188 |
UE supporting E-UTRA and 4DL CA with CA configurations in Table 4.1-4 |
|||||||||||||||
7.6.2A.8 |
Out-of-band blocking for 5DL CA |
Rel-11 |
C221 |
UE supporting E-UTRA and 5DL with CA configurations in Table 4.1-5 |
E15 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
|||||||||||
Rel-12 |
C222 |
UE supporting E-UTRA and 5DL CA with CA configurations in Table 4.1-5 |
|||||||||||||||
Rel-12 |
C223 |
UE supporting E-UTRA and 5DL CA with CA configurations in Table 4.1-5 |
|||||||||||||||
7.6.2A.9 |
Out-of-band blocking for 6DL CA |
Rel-14 |
C342 |
UE supporting E-UTRA and 6DL CA with CA configurations in Table 4.1-6 |
E26 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
7.6.2A.10 |
Out-of-band blocking for 7DL CA |
Rel-14 |
C358 |
UE supporting E-UTRA FDD and TDD and 7DL CA with FDD as PCell (UE Category8, and Category 11 and onwards) |
TBD |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
7.6.2B |
Out-of-band blocking for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
7.6.2D.1 |
Out-of-band blocking for ProSe Direct Discovery |
Rel-12 |
C163 |
UE supporting E-UTRA and ProSe direct discovery |
D10 |
FDD, TDD |
|||||||||||
7.6.2D.2 |
Out-of-band blocking for ProSe Direct Communication |
Rel-12 |
C162 |
UE supporting E-UTRA and ProSe direct communication |
D10 |
FDD, TDD |
|||||||||||
7.6.2E |
Out of-band blocking for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0) |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.6.2EA |
Out of-band blocking for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.6.2EB |
Out-of-band blocking for UE category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
7.6.2EC |
Out of-band blocking for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.6.2F |
Out-of-band blocking for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
7.6.2G.1 |
Out-of-band blocking for V2X Communication/ Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
7.6.2G.2 |
Out-of-band blocking for V2X Communication / Simultaneous E-UTRA V2X sidelink and E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
7.6.2G.3 |
Out-of-band blocking for V2X Communication / Intra-band contiguous multi-carrier operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
7.6.3 |
Narrow band blocking |
Rel-8 |
C113 |
UE supporting E-UTRA |
D15 |
FDD, TDD |
|||||||||||
7.6.3_1 |
Out of-band blocking with 4 Rx antenna ports |
Rel-10 |
C113a |
UE supporting E-UTRA with 4Rx antenna ports |
D09 |
FDD, TDD |
|||||||||||
7.6.3A.1 |
Narrow band blocking for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.6.3A.2 |
Narrow band blocking for CA (intra-band contiguous DL CA without UL CA) |
Rel-10 |
C20 |
UE supporting E-UTRA and intra-band contiguous DL CA |
E08 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.6.3A.3 |
Narrow band blocking for CA (inter-band DL CA without UL CA) |
Rel-10 |
C21 |
UE supporting E-UTRA and inter-band DL CA |
E10 |
FDD_2Rx. FDD_4Rx. TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-12 |
C146 |
UE supporting E-UTRA and 2DL CA with FDD-TDD inter-band DL CA |
|||||||||||||||
7.6.3A.4 |
Narrow band blocking for CA (intra-band non-contiguous DL CA without UL CA) |
Rel-11 |
C43 |
UE supporting E-UTRA and intra-band non-contiguous DL CA |
E09 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.6.3A.5 |
Narrow band blocking for 3DL CA |
Rel-10 |
C121 |
UE supporting E-UTRA and 3DL with CA configurations in Table 4.1-3 |
E19 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-11 |
C122 |
UE supporting E-UTRA and 3DL with CA configurations in Table 4.1-3 |
|||||||||||||||
Rel-12 |
C123 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 |
|||||||||||||||
7.6.3A.7 |
Narrow band blocking for 4DL CA |
Rel-11 |
C187 |
UE supporting E-UTRA and 4DL with CA configurations in Table 4.1-4 |
E21 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-11 |
TBD |
UE supporting E-UTRA and 4DL with CA configurations in Table 4.1-4 |
|||||||||||||||
Rel-12 |
C188 |
UE supporting E-UTRA and 4DL CA with CA configurations in Table 4.1-4 |
|||||||||||||||
7.6.3A.8 |
Narrow band blocking for 5DL CA |
Rel-11 |
C221 |
UE supporting E-UTRA and 5DL with CA configurations in Table 4.1-5 |
E15 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-12 |
C222 |
UE supporting E-UTRA and 5DL CA with CA configurations in Table 4.1-5 |
|||||||||||||||
Rel-12 |
C223 |
UE supporting E-UTRA and 5DL CA with CA configurations in Table 4.1-5 |
|||||||||||||||
7.6.3A.9 |
Narrow band blocking for 6DL CA |
Rel-14 |
C342 |
UE supporting E-UTRA and 6DL CA with CA configurations in Table 4.1-6 |
E26 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
7.6.3A.10 |
Narrow band blocking for 7DL CA |
Rel-14 |
C358 |
UE supporting E-UTRA FDD and TDD and 7DL CA with FDD as PCell (UE Category8, and Category 11 and onwards) |
TBD |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
7.6.3B |
Narrow band blocking for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
7.6.3D.1 |
Narrow band blocking for ProSe Direct Discovery |
Rel-12 |
C163 |
UE supporting E-UTRA and ProSe direct discovery |
D10 |
FDD, TDD |
|||||||||||
7.6.3D.2 |
Narrow band blocking for ProSe Direct Communication |
Rel-12 |
C162 |
UE supporting E-UTRA and ProSe direct communication |
D10 |
FDD, TDD |
|||||||||||
7.6.3E |
Narrow band blocking for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0) |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.6.3EA |
Narrow band blocking for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.6.3EB |
Narrow band blocking for UE category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
7.6.3EC |
Narrow band blocking for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.7 |
Spurious response |
Rel-8 |
C113 |
UE supporting E-UTRA |
D15 |
FDD, TDD |
|||||||||||
7.7_1 |
Spurious response with 4 Rx antenna ports |
Rel-10 |
C113a |
UE supporting E-UTRA with 4Rx antenna ports |
D09 |
FDD, TDD |
|||||||||||
7.7A.1 |
Spurious response for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.7A.2 |
Spurious response for CA (intra-band contiguous DL CA without UL CA) |
Rel-10 |
C20 |
UE supporting E-UTRA and intra-band contiguous DL CA |
E08 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.7A.3 |
Spurious response for CA (inter-band DL CA without UL CA) |
Rel-10 |
C21 |
UE supporting E-UTRA and inter-band DL CA |
E10 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-12 |
C146 |
UE supporting E-UTRA and 2DL CA with FDD-TDD inter-band CA |
|||||||||||||||
Rel-13 |
C207 |
UE supporting E-UTRA and 2DL CA with FDD-TDD inter-band CA under FS3 |
E12 |
||||||||||||||
Rel-13 |
C208 |
UE supporting E-UTRA and 2DL CA with TDD inter-band CA under FS3 |
|||||||||||||||
7.7A.4 |
Spurious response for CA (intra-band non-contiguous DL CA without UL CA) |
Rel-11 |
C43 |
UE supporting E-UTRA and intra-band non-contiguous DL CA |
E09 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.7A.5 |
Spurious response for 3DL CA |
Rel-10 |
C121 |
UE supporting E-UTRA and 3DL with CA configurations in Table 4.1-3 |
E19 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-11 |
C122 |
UE supporting E-UTRA and 3DL with CA configurations in Table 4.1-3 |
|||||||||||||||
Rel-12 |
C123 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 |
|||||||||||||||
Rel-13 |
C268 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 under FS3 |
|||||||||||||||
Rel-13 |
C269 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 under FS3 |
|||||||||||||||
7.7A.7 |
Spurious response for 4DL CA |
Rel-11 |
C187 |
UE supporting E-UTRA and 4DL with CA configurations in Table 4.1-4 |
E21 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-11 |
C211 |
UE supporting E-UTRA and 4DL with CA configurations in Table 4.1-4 |
|||||||||||||||
Rel-12 |
C188 |
UE supporting E-UTRA and 4DL CA with CA configurations in Table 4.1-4 |
|||||||||||||||
7.7A.8 |
Spurious response for 5DL CA |
Rel-11 |
C221 |
UE supporting E-UTRA and 5DL with CA configurations in Table 4.1-5 |
E15 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-12 |
C222 |
UE supporting E-UTRA and 5DL CA with CA configurations in Table 4.1-5 |
|||||||||||||||
Rel-12 |
C223 |
UE supporting E-UTRA and 5DL CA with CA configurations in Table 4.1-5 |
|||||||||||||||
7.7A.9 |
Spurious response for 6DL CA |
Rel-14 |
C342 |
UE supporting E-UTRA and 6DL CA with CA configurations in Table 4.1-6 |
E26 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
7.7A.10 |
Spurious response for 7DL CA |
Rel-14 |
C358 |
UE supporting E-UTRA FDD and TDD and 7DL CA with FDD as PCell (UE Category8, and Category 11 and onwards) |
TBD |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
7.7B |
Spurious response for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
7.7D.1 |
Spurious response for ProSe Direct Discovery |
Rel-12 |
C163 |
UE supporting E-UTRA and ProSe direct discovery |
D10 |
FDD, TDD |
|||||||||||
7.7D.2 |
Spurious response for ProSe Direct Communication |
Rel-12 |
C162 |
UE supporting E-UTRA and ProSe direct communication |
D10 |
FDD, TDD |
|||||||||||
7.7E |
Spurious response for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0) |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.7EA |
Spurious response for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.7EB |
Spurious response for UE Category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
7.7EC |
Spurious response for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.7F |
Spurious response for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
7.7G.1 |
Spurious response for V2X Communication / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
7.7G.2 |
Spurious response for V2X Communication / Simultaneous E-UTRA V2X sidelink and E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
7.7G.3 |
Spurious response for V2X Communication / Intra-band contiguous multi-carrier operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
7.8.1 |
Wide band Intermodulation |
Rel-8 |
C113 |
UE supporting E-UTRA |
D15 |
FDD, TDD |
|||||||||||
7.8.1_1 |
Wide band Intermodulation with 4 Rx antenna ports |
Rel-10 |
C113a |
UE supporting E-UTRA with 4Rx antenna ports |
D09 |
FDD, TDD |
|||||||||||
7.8.1A.1 |
Wide band Intermodulation for CA (intra-band contiguous DL CA and UL CA) |
Rel-10 |
C19 |
UE supporting E-UTRA and intra-band contiguous DL CA and UL CA |
E01 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.8.1A.2 |
Wide band Intermodulation for CA (intra-band contiguous DL CA without UL CA) |
Rel-10 |
C20 |
UE supporting E-UTRA and intra-band contiguous DL CA |
E08 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.8.1A.3 |
Wide band Intermodulation for CA (inter-band DL CA without UL CA) |
Rel-10 |
C21 |
UE supporting E-UTRA and inter-band DL CA |
E10 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-12 |
C146 |
UE supporting E-UTRA and 2DL CA with FDD-TDD inter-band CA |
|||||||||||||||
Rel-13 |
C207 |
UE supporting E-UTRA and 2DL CA with FDD-TDD inter-band CA under FS3 |
|||||||||||||||
Rel-13 |
C208 |
UE supporting E-UTRA and 2DL CA with TDD-TDD inter-band CA under FS3 |
|||||||||||||||
7.8.1A.4 |
Wide band Intermodulation for CA (intra-band non-contiguous DL CA without UL CA) |
Rel-11 |
C43 |
UE supporting E-UTRA and intra-band non-contiguous DL CA |
E09 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.8.1A.5 |
Wideband intermodulation for 3DL CA |
Rel-10 |
C121 |
UE supporting E-UTRA and 3DL with CA configurations in Table 4.1-3 |
E24 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-11 |
C122 |
UE supporting E-UTRA and 3DL with CA configurations in Table 4.1-3 |
|||||||||||||||
Rel-12 |
C123 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 |
|||||||||||||||
Rel-13 |
C268 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 under FS3 |
|||||||||||||||
Rel-13 |
C269 |
UE supporting E-UTRA and 3DL CA with CA configurations in Table 4.1-3 under FS3 |
|||||||||||||||
7.8.1A.7 |
Wideband intermodulation for 4DL CA |
Rel-11 |
C187 |
UE supporting E-UTRA and 4DL with CA configurations in Table 4.1-4 |
E25 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-11 |
C211 |
UE supporting E-UTRA and 4DL with CA configurations in Table 4.1-4 |
|||||||||||||||
Rel-12 |
C188 |
UE supporting E-UTRA and 4DL CA with CA configurations in Table 4.1-4 |
|||||||||||||||
7.8.1A.8 |
Wideband intermodulation for 5DL CA |
Rel-11 |
C221 |
UE supporting E-UTRA and 5DL with CA configurations in Table 4.1-5 |
E15 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
Rel-12 |
C222 |
UE supporting E-UTRA and 5DL CA with CA configurations in Table 4.1-5 |
|||||||||||||||
Rel-12 |
C223 |
UE supporting E-UTRA and 5DL CA with CA configurations in Table 4.1-5 |
|||||||||||||||
7.8.1A.9 |
Wideband intermodulation for 6DL CA |
Rel-14 |
C342 |
UE supporting E-UTRA and 6DL CA with CA configurations in Table 4.1-6 |
E26 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx, FDD-TDD_2Rx, FDD-TDD_4Rx |
Note 7 |
||||||||||
7.8.1B |
Wide band intermodulation for UL-MIMO |
Rel-10 |
C07 |
UE supporting E-UTRA and UL_MIMO |
D05 |
FDD, TDD |
|||||||||||
7.8.1D.1 |
Wide band Intermodulation for ProSe Direct Discovery |
Rel-12 |
C163 |
UE supporting E-UTRA and ProSe direct discovery |
D10 |
FDD, TDD |
|||||||||||
7.8.1D.2 |
Wide band Intermodulation for ProSe Direct Communication |
Rel-12 |
C162 |
UE supporting E-UTRA and ProSe direct communication |
D10 |
FDD, TDD |
|||||||||||
7.8.1E |
Wide band Intermodulation for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0) |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.8.1EA |
Wide band Intermodulation for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.8.1EB |
Wide band Intermodulation for UE category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
7.8.1EC |
Wide band intermodulation for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.8.1F |
Wide band Intermodulation for category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
7.8.1G.1 |
Wide band Intermodulation for V2X Communication / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
7.8.1G.2 |
Wide band Intermodulation for V2X Communication / Simultaneous E-UTRA V2X sidelink and E-UTRA uplink transmissions |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
7.8.1G.3 |
Wide band Intermodulation for V2X Communication / Intra-band contiguous multi-carrier operation |
Rel-14 |
C333 |
UE supporting V2X Sidelink communication and multi-carrier configurations |
E17 |
TDD |
|||||||||||
7.9 |
Spurious emissions |
Rel-8 |
C113 |
UE supporting E-UTRA |
D15 |
FDD, TDD |
|||||||||||
7.9_1 |
Spurious emissions with 4 Rx antenna ports |
Rel-10 |
C113a |
UE supporting E-UTRA with 4Rx antenna ports |
D09 |
FDD, TDD |
|||||||||||
7.9A |
Spurious emissions for CA |
Rel-10 |
C120 |
UE supporting E-UTRA and inter-band DL CA with a DL-only band |
E13 |
FDD_2Rx, FDD_4Rx, TDD_2Rx, TDD_4Rx |
Note 7 |
||||||||||
7.9E |
Spurious emissions for UE category 0 |
Rel-12 |
C112 |
UE supporting E-UTRA (UE category 0) |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.9EA |
Spurious emissions for UE category M1 |
Rel-13 |
C112a |
UE supporting E-UTRA and UE category M1 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.9EB |
Spurious emissions for UE Category 1bis |
Rel-13 |
C112c |
UE supporting E-UTRA and UE category 1bis |
D01 |
FDD, TDD |
|||||||||||
7.9EC |
Spurious emissions for UE category M2 |
Rel-14 |
C112d |
UE supporting E-UTRA and UE category M2 |
D01 |
FDD, HD-FDD, TDD |
|||||||||||
7.9F |
Spurious emissions for Category NB1 and NB2 |
Rel-13 |
C112b |
UE supporting NB-IoT |
D12, D13, D18 |
HD-FDD, TDD |
|||||||||||
7.9G.1 |
Spurious emissions for V2X Communication / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
Performance Requirement |
|||||||||||||||||
8.2.1.1.1 |
FDD PDSCH Single Antenna Port Performance |
Rel-8 |
C01 |
UE supporting E-UTRA FDD |
Each ""Test Number"" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Test execution not necessary if 8.2.1.1.1_A.1 or 8.2.1.1.1_A.2 is executed. Note 7 |
||||||||||
8.2.1.1.1_1 |
FDD PDSCH Single Antenna Port Performance (Release 9 and forward) |
Rel-9 |
C31 |
UE supporting E-UTRA FDD (UE categories 1, 2) |
Each ""Test Number"" to be performed once, in a chosen band supporting tested BW |
Test execution not necessary if 8.2.1.1.1_A.1 or 8.2.1.1.1_A.2 is executed. |
|||||||||||
8.2.1.1.1_A.1 |
FDD PDSCH Single Antenna Port Performance for CA (2 DL CA) |
Rel-10 |
C102 |
UE supporting E-UTRA FDD and intra-band contiguous DL CA or inter-band DL CA (UE Category >= 2) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Test execution not necessary if 8.2.1.1.1_A.2 or 8.2.1.1.1_A.4 or 8.2.1.1.1_A.5 or 8.13.1.2.2 or 8.13.1.2.3 or 8.13.1.2.4 or 8.13.1.2.5 is executed. Note 7 |
||||||||||
Rel-11 |
C103 |
UE supporting E-UTRA FDD and Downlink Intra-band non-contiguous CA (UE Category >= 2) |
|||||||||||||||
8.2.1.1.1_A.2 |
FDD PDSCH Single Antenna Port Performance for CA (3DL CA) |
Rel-10 |
C124 |
UE supporting E-UTRA FDD and 3DL with CA configurations in Table 4.1-3 (UE Category >= 5) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Test execution not necessary if 8.2.1.1.1_A.4 or 8.2.1.1.1_A.5 or 8.13.1.2.3 or 8.13.1.2.4 or 8.13.1.2.5 is executed. |
||||||||||
Rel-11 |
C125 |
UE supporting E-UTRA FDD and 3DL with CA configurations in Table 4.1-3 (UE Category >= 5) |
Note 7 |
||||||||||||||
8.2.1.1.1_A.4 |
FDD PDSCH Single Antenna Port Performance for CA (4DL CA) |
Rel-11 |
C214 |
UE supporting E-UTRA FDD and 4DL CA configurations in Table 4.1-4 (UE Category >= 8) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Test execution not necessary if 8.2.1.1.1_A.5 or 8.13.1.2.4 or 8.13.1.2.5 is executed. Note 7 |
||||||||||
8.2.1.1.1_A.5 |
FDD PDSCH Single Antenna Port Performance for CA (5DL CA) |
Rel-11 |
C215 |
UE supporting E-UTRA FDD and 5DL with CA configurations in Table 4.1-5 (UE Category 8, >= 11) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Test execution not necessary if 8.13.1.2.5 is executed. Note 7 |
||||||||||
Rel-12 |
C216 |
UE supporting E-UTRA FDD and 5DL with CA configurations in Table 4.1-5 (UE Category 8, >= 11) |
|||||||||||||||
8.2.1.1.1_A.6 |
FDD PDSCH Single Antenna Port Performance for CA (6DL CA) |
Rel-14 |
C349 |
UE supporting E-UTRA FDD and 6DL with CA configurations in Table 4.1-6 (UE Category 8, >= 11) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.1.1.2 |
FDD PDSCH Single Antenna Port Performance with 1 PRB in presence of MBSFN |
Rel-8 |
C01 |
UE supporting E-UTRA FDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.2.1 |
FDD PDSCH Transmit Diversity 2×2 |
Rel-8 |
C01 |
UE supporting E-UTRA FDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.2.1_1 |
FDD PDSCH Transmit Diversity 2×2 (Release 9 and forward) |
Rel-9 |
C15 |
UE supporting E-UTRA FDD (UE category 1) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.2.2 |
FDD PDSCH Transmit Diversity 4×2 |
Rel-8 |
C09 |
UE supporting E-UTRA FDD and operating bands supporting 1,4 MHz Bandwidth |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.2.2_1 |
FDD PDSCH Transmit Diversity 4×2 (Release 9 and forward) |
Rel-9 |
C01 |
UE supporting E-UTRA FDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.2.3_C.1 |
FDD PDSCH Transmit diversity 2×2 for eICIC (non-MBFSN ABS) |
Rel-10 |
C29 |
UEs supporting E-UTRA FDD and Feature Group Indictor 115 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.2.3_E.1 |
FDD PDSCH Transmit diversity 2×2 for feICIC (non-MBFSN ABS) |
Rel-11 |
C77 |
UE supporting E-UTRA FDD and CRS interference handling (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.2.4 |
FDD PDSCH Transmit Diversity 2×2 with TM3 Interference Model — Enhanced Performance Requirement Type A |
Rel-11 |
C44 |
UE supporting E-UTRA FDD and the enhanced performance requirements type A for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.2.5 |
FDD PDSCH Transmit Diversity 2×2 with TM2 Interference Model — Enhanced Performance Requirement Type B |
Rel-12 |
C150 |
UE supporting E-UTRA FDD and the enhanced performance requirements type B for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.2.6 |
FDD PDSCH Transmit Diversity 2×2 with TM9 Interference Model — Enhanced Performance Requirement Type B |
Rel-12 |
C150 |
UE supporting E-UTRA FDD and the enhanced performance requirements type B for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.3.1 |
FDD PDSCH Open Loop Spatial Multiplexing 2×2 |
Rel-8 |
C13b |
UE supporting E-UTRA FDD (UE categories >=2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
Test execution not necessary if 8.2.1.3.1_A.1 or 8.2.1.3.1_A.2 is executed. |
|||||||||||
8.2.1.3.1_1 |
FDD PDSCH Open Loop Spatial Multiplexing 2×2 (Release 11 and forward) |
Rel-11 |
C13b |
UE supporting E-UTRA FDD (UE categories >=2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
Test execution not necessary if 8.2.1.3.1_A.1 or 8.2.1.3.1_A.2 is executed. |
|||||||||||
8.2.1.3.1_A.1 |
FDD PDSCH Open Loop Spatial Multiplexing 2×2 for CA (2 DL CA) |
Rel-10 |
C101 |
UE supporting E-UTRA FDD and intra-band contiguous DL CA or inter-band DL CA (UE Category >=2) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
If 8.2.1.3.1_A.2 is executed for a CA capability, test execution is not necessary for that CA capability. |
||||||||||
Rel-11 |
C103 |
UE supporting E-UTRA FDD and intra-band non-contiguous DL CA (UE Category >= 2) |
Note 7 |
||||||||||||||
8.2.1.3.1_A.2 |
FDD PDSCH Open Loop Spatial Multiplexing 2×2 for CA (3DL CA) |
Rel-10 |
C124 |
UE supporting E-UTRA FDD and 3DL with CA configurations in Table 4.1-3 (UE Category >= 5) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
If 8.2.1.3.1_A.3 is executed for a CA capability, test execution is not necessary for that CA capability. Note 7 |
||||||||||
Rel-11 |
C125 |
UE supporting E-UTRA FDD and 3DL with CA configurations in Table 4.1-3 (UE Category >= 5) |
|||||||||||||||
8.2.1.3.1_A.3 |
FDD PDSCH Open Loop Spatial Multiplexing 2×2 for CA (4DL CA) |
Rel-11 |
C214 |
UE supporting E-UTRA FDD and 4DL CA configurations in Table 4.1-4 (UE Category >= 8) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
If 8.2.1.3.1_A.4 is executed for a CA capability, test execution is not necessary for that CA capability. Note 7 |
||||||||||
8.2.1.3.1_A.4 |
FDD PDSCH Open Loop Spatial Multiplexing 2×2 for CA (5DL CA) |
Rel-11 |
C215 |
UE supporting E-UTRA FDD and 5DL with CA configurations in Table 4.1-5 (UE Category 8, >= 11) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
If 8.2.1.3.1_A.5 is executed for a CA capability, test execution is not necessary for that CA capability. Note 7 |
||||||||||
Rel-12 |
C216 |
UE supporting E-UTRA FDD and 5DL CA configurations in Table 4.1-5 (UE Category 8, >= 11) |
|||||||||||||||
8.2.1.3.1_A.5 |
FDD PDSCH Open Loop Spatial Multiplexing 2×2 for CA (6DL CA) |
Rel-14 |
C349 |
UE supporting E-UTRA FDD and 6DL CA configurations in Table 4.1-6 (UE Category 8, >= 11) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.1.3.1A_A.1 |
FDD Soft buffer management test for CA (2 DL CA) |
Rel-10 |
C104 |
UE supporting E-UTRA FDD and intra-band contiguous DL CA or inter-band DL CA (UE category 3 and 4) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
Rel-11 |
C106 |
UE supporting E-UTRA FDD and Downlink Intra-band non-contiguous CA (UE categories 3 and 4) |
|||||||||||||||
8.2.1.3.1B |
FDD PDSCH Open Loop Spatial Multiplexing 2×2 — Enhanced Performance Requirement Type C |
Rel-12 |
C142 |
UE supporting E-UTRA FDD and Enhanced Performance Requirement TypeC for LTE (UE Category >= 2) |
Each ""Test Number"" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.3.1C |
FDD PDSCH Open Loop Spatial Multiplexing 2×2 with TM1 Interference — Enhanced Performance Requirement Type C |
Rel-12 |
C142 |
UE supporting E-UTRA FDD and Enhanced Performance Requirement TypeC for LTE (UE Category >= 2) |
Each ""Test Number"" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.3.2 |
FDD PDSCH Open Loop Spatial Multiplexing 4×2 |
Rel-8 |
C13 b |
UE supporting E-UTRA FDD (UE categories >=2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.3.3_C.1 |
FDD PDSCH Open Loop Spatial Multiplexing 2×2 for eICIC (non-MBSFN ABS) |
Rel-10 |
C29 |
UEs supporting E-UTRA FDD and Feature Group Indictor 115 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.3.3_C.2 |
FDD PDSCH Open Loop Spatial Multiplexing 2×2 for eICIC (MBSFN ABS) |
Rel-10 |
C29 |
UEs supporting E-UTRA FDD and Feature Group Indictor 115 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.3.3_E.1 |
FDD PDSCH Open Loop Spatial Multiplexing 2×2 for feICIC (non-MBSFN ABS) |
Rel-11 |
C77 |
UE supporting E-UTRA FDD and CRS interference handling and Feature Group Indicator 115 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.4.1 |
FDD PDSCH Closed Loop Single/Multi Layer Spatial Multiplexing 2×2 |
Rel-8 only |
C01 |
UE supporting E-UTRA FDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.4.1_1 |
FDD PDSCH Closed Loop Single/Multi Layer Spatial Multiplexing 2×2 (Release 9 and forward) |
Rel-9 |
C01 |
UE supporting E-UTRA FDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.4.1_E.1 |
FDD PDSCH Closed Loop Single/Multi Layer Spatial Multiplexing 2×2 for feICIC (non-MBSFN ABS) |
Rel-11 |
C77 |
UE supporting E-UTRA FDD and CRS interference handling and Feature Group Indicator 115 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.4.1_H |
FDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 2×2 for 256QAM in DL |
Rel-12 |
C01h |
UE supporting E-UTRA FDD and 256QAM in DL |
|||||||||||||
8.2.1.4.2 |
FDD PDSCH Closed Loop Single/Multi Layer Spatial Multiplexing 4×2 |
Rel-8 only |
C01 |
UE supporting E-UTRA FDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
Test execution not necessary if 8.2.1.4.2_A.1 or 8.2.1.4.2_A.2 is executed. |
|||||||||||
8.2.1.4.2_1 |
FDD PDSCH Closed Loop Single/Multi Layer Spatial Multiplexing 4×2 (Release 9 and forward) |
Rel-9 |
C01 |
UE supporting E-UTRA FDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
Test execution not necessary if 8.2.1.4.2_A.1 or 8.2.1.4.2_A.2 is executed. |
|||||||||||
8.2.1.4.2_A.1 |
FDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for CA (2 DL CA) |
Rel-10 |
C102 |
UE supporting E-UTRA FDD and intra-band contiguous DL CA or inter-band DL CA (UE Category >= 2) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Test execution not necessary if 8.2.1.4.2_A.2 or 8.2.1.4.2_A.3 or 8.2.1.4.2_A.4 or 8.13.1.1.1.2 or 8.13.1.1.1.3 or 8.13.1.1.1.4 or 8.13.1.1.1.5 is executed. |
||||||||||
Rel-11 |
C103 |
UE supporting E-UTRA FDD and intra-band non-contiguous DL CA (UE Category >= 2) |
Note 7 |
||||||||||||||
8.2.1.4.2_A.2 |
FDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for CA (3DL CA) |
Rel-10 |
C124 |
UE supporting E-UTRA FDD and 3DL with CA configurations in Table 4.1-3 (UE Category >= 5) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Test execution not necessary if 8.2.1.4.2_A.3 or 8.2.1.4.2_A.4 or 8.13.1.1.1.2 or 8.13.1.1.1.3 or 8.13.1.1.1.4 or 8.13.1.1.1.5 is executed. Note 7 |
||||||||||
Rel-11 |
C125 |
UE supporting E-UTRA FDD and 3DL with CA configurations in Table 4.1-3 (UE Category >= 5) |
|||||||||||||||
8.2.1.4.2_A.3 |
FDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for CA (4DL CA) |
Rel-11 |
C212 |
UE supporting E-UTRA FDD and 4DL with CA configurations in Table 4.1-4 (UE Category >= 5) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Test execution not necessary if 8.2.1.4.2_A.4 or 8.13.1.1.1.2 or 8.13.1.1.1.3 or 8.13.1.1.1.4 or 8.13.1.1.1.5 is executed. Note 7 |
||||||||||
8.2.1.4.2_A.4 |
FDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for CA (5DL CA) |
Rel-11 |
C212a |
UE supporting E-UTRA FDD and 5DL with CA configurations in Table 4.1-5 (UE Category 8, >= 11) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Test execution not necessary if 8.13.1.1.1.2 or 8.13.1.1.1.3 or 8.13.1.1.1.4 or 8.13.1.1.1.5 is executed. Note 7 |
||||||||||
Rel-12 |
C212b |
UE supporting E-UTRA FDD and 5DL with CA configurations in Table 4.1-5 (UE Category 8, >= 11) |
|||||||||||||||
8.2.1.4.2_A.5 |
FDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for CA (6DL CA) |
Rel-14 |
C349 |
UE supporting E-UTRA FDD and 6DL with CA configurations in Table 4.1-6 (UE Category 8, >= ≥ 11) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.1.4.2A |
FDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 2×2 – Enhanced Performance Requirement Type C |
Rel-12 |
C142 |
UE supporting E-UTRA FDD and Enhanced Performance Requirement TypeC for LTE (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
8.2.1.4.2A |
|||||||||||
8.2.1.4.3 |
FDD PDSCH Closed Loop Single Layer Spatial Multiplexing 2×2 with TM4 Interference model – Enhanced Performance Requirement Type A |
Rel-11 |
C44 |
UE supporting E-UTRA FDD and the enhanced performance requirements type A for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.4.3A |
FDD PDCSH Closed Loop Multi-Layer Spatial Multiplexing 4X2 for Dual Connectivity |
Rel-12 |
C169 |
UE supporting E-UTRA FDD and Dual Connectivity (UE Category >= 3) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.1.4.4 |
FDD PDSCH Closed Loop Single Layer Spatial Multiplexing 2×2 with TM4 Interference Model – Enhanced Performance Requirement Type B |
Rel-12 |
C150 |
UE supporting E-UTRA FDD and the enhanced performance requirements type B for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.1.7_A.1 |
FDD Carrier aggregation with power imbalance (intra-band contiguous DL CA) |
Rel-10 |
C22 |
UE supporting E-UTRA FDD and intra-band contiguous DL CA |
TBD |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.1.9 |
FDD PDSCH in HST-SFN scenario |
Rel-14 |
C299 |
UEs supporting E-UTRA FDD and high speed enhancement for measurement |
|||||||||||||
8.2.1.10 |
FDD PDSCH minimum channel spacing for intra-band contiguous CA |
Rel-15 |
C125a |
UE supporting E-UTRA FDD and intra-band contiguous DL CA (UE Category >= 5) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.2.1 |
Void |
||||||||||||||||
8.2.2.1.1 |
TDD PDSCH Single Antenna Port Performance |
Rel-8 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
Test execution not necessary if 8.2.2.1.1_A.1 or 8.2.2.1.1_A.2 is executed. |
|||||||||||
8.2.2.1.1_1 |
TDD PDSCH Single Antenna Port Performance (Release 9 and forward) |
Rel-9 |
C54 |
UE supporting E-UTRA TDD (UE categories 1, 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
Test execution not necessary if 8.2.2.1.1_A.1 or 8.2.2.1.1_A.2 is executed. |
|||||||||||
8.2.2.1.1_A.1 |
TDD PDSCH Single Antenna Port Performance for CA (2DL CA) |
Rel-10 |
C110 |
UE supporting E-UTRA TDD and intra-band contiguous DL CA or interband DL CA (UE Category >= 5) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Test execution not necessary if 8.2.2.1.1_A.2 is executed. |
||||||||||
Rel-11 |
C109 |
UE supporting E-UTRA TDD and Intra-band non-contiguous DL CA(UE Category >= 5) |
Note 7 |
||||||||||||||
8.2.2.1.1_A.2 |
TDD PDSCH Single Antenna Port Performance for CA (3DL CA) |
Rel-10 |
C128 |
UE supporting E-UTRA TDD and 3DL with i CA configurations in Table 4.1-3 (UE Category >= 5) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
Rel-11 |
C129 |
UE supporting E-UTRA TDD and 3DL with CA configurations in Table 4.1-3 (UE Category >= 5) |
|||||||||||||||
8.2.2.1.1_A.3 |
TDD PDSCH Single Antenna Port Performance for CA (4DL CA) |
Rel-11 |
C194 |
CA configurations in Table 4.1-4 (UE Category >= 8) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.2.1.1_A.4 |
TDD PDSCH Single Antenna Port Performance for CA (5DL CA) |
Rel-11 |
C194a |
UE supporting E-UTRA FDD and 5DL with CA configurations in Table 4.1-5 (UE Category 8, >= 11) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
Rel-12 |
C194b |
UE supporting E-UTRA FDD and 5DL with CA configurations in Table 4.1-5 (UE Category 8, >= 11) |
|||||||||||||||
8.2.2.1.2 |
TDD PDSCH Single Antenna Port Performance with 1PRB in the presence of MBSFN |
Rel-8 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.2 |
Void |
||||||||||||||||
8.2.2.2.1 |
TDD PDSCH Transmit Diversity 2×2 |
Rel-8 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.2.1_1 |
TDD PDSCH Transmit Diversity 2×2 (Release 9 and forward) |
Rel-9 |
C16 |
UE supporting E-UTRA TDD (UE category 1) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.2.2 |
TDD PDSCH Transmit Diversity 4×2 |
Rel-8 |
C10 |
UE supporting E-UTRA TDD and operating bands supporting 1,4 MHz Bandwidth |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.2.2_1 |
TDD PDSCH Transmit Diversity 4×2 (Release 9 and forward) |
Rel-9 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.2.3_C.1 |
TDD PDSCH Transmit diversity 2×2 for eICIC (non-MBFSN ABS) |
Rel-10 |
C30 |
UEs supporting E-UTRA TDD and Feature Group Indictor 115 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.2.3_E.1 |
TDD PDSCH Transmit diversity 2×2 for feICIC (non-MBFSN ABS) |
Rel-11 |
C78 |
UE supporting E-UTRA TDD and CRS interference handling and ss-CCH interference handling and Feature Group Indicator 115 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.2.4 |
TDD PDSCH Transmit Diversity 2×2 with TM3 Interference Model – Enhanced Performance Requirement Type A |
Rel-11 |
C45 |
UE supporting E-UTRA TDD and the enhanced performance requirements type A for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.2.5 |
TDD PDSCH Transmit Diversity 2×2 for eIMTA (when EIMTA-MainConfigServCell-r12 is configured) |
Rel-12 |
C274 |
UE supporting E-UTRA TDD and eIMTA TDD UL-DL reconfiguration |
|||||||||||||
8.2.2.2.6 |
TDD PDSCH Transmit Diversity 2×2 with TM2 Interference Model – Enhanced Performance Requirement Type B |
Rel-12 |
C151 |
UE supporting E-UTRA TDD and the enhanced performance requirements type B for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.2.7 |
TDD PDSCH Transmit Diversity 2×2 with TM9 Interference Model – Enhanced Performance Requirement Type B |
Rel-12 |
C151 |
UE supporting E-UTRA TDD and the enhanced performance requirements type B for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.3 |
Void |
||||||||||||||||
8.2.2.3.1 |
TDD PDSCH Open Loop Spatial Multiplexing 2×2 |
Rel-8 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
Test execution not necessary if 8.2.2.3.1_A.1 or .2 is executed. |
|||||||||||
8.2.2.3.1_1 |
TDD PDSCH Open Loop Spatial Multiplexing 2×2 (Release 11 and forward) |
Rel-11 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
Test execution not necessary if 8.2.2.3.1_A.1 or .2 is executed. |
|||||||||||
8.2.2.3.1_A.1 |
TDD PDSCH Open Loop Spatial Multiplexing 2×2 for CA (2DL CA) |
Rel-10 |
C110 |
UE supporting E-UTRA TDD and intra-band contiguous DL CA or interband DL CA (UE Category >= 5) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
If 8.2.2.3.1_A.2 is executed for a CA capability, test execution is not necessary for that CA capability |
||||||||||
Rel-11 |
C109 |
UE supporting E-UTRA TDD and intra-band non-contiguous DL CA (UE Category >= 5) |
Note 7 |
||||||||||||||
8.2.2.3.1_A.2 |
TDD PDSCH Open Loop Spatial Multiplexing 2×2 for CA (3DL CA) |
Rel-10 |
C128 |
UE supporting E-UTRA TDD and 3DL with CA configurations in Table 4.1-3 (UE Category >= 5) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
Rel-11 |
C129 |
UE supporting E-UTRA TDD and 3DL with CA configurations in Table 4.1-3 (UE Category >= 5) |
|||||||||||||||
8.2.2.3.1_A.3 |
TDD PDSCH Open Loop Spatial Multiplexing 2×2 for CA(4DL CA) |
Rel-11 |
C194 |
UE supporting 4DL CA configurations in Table 4.1-4.(UE category >=8) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.2.3.1_A.4 |
TDD PDSCH Open Loop Spatial Multiplexing 2×2 for CA (5DL CA) |
Rel-11 |
C194a |
UE supporting E-UTRA FDD and 5DL with CA configurations in Table 4.1-5 (UE Category 8, >= 11) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
Rel-12 |
C194b |
UE supporting E-UTRA FDD and 5DL with CA configurations in Table 4.1-5 (UE Category 8, >= 11) |
|||||||||||||||
8.2.2.3.1A_A.1 |
TDD Soft buffer management for CA (2 DL CA) |
Rel-10 |
C105 |
UE supporting E-UTRA TDD and intra-band contiguous DL CA or inter-band DL CA (UE category 3 and 4) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
TBD |
||||||||||
Rel-11 |
C72 |
UE supporting E-UTRA TDD and intra-band non-contiguous DL CA (UE category 3 and 4) |
Note 7 |
||||||||||||||
8.2.2.3.1B |
TDD PDSCH Open Loop Spatial Multiplexing 2×2 – Enhanced Performance Requirement Type C |
Rel-12 |
C143 |
UE supporting E-UTRA TDD and Enhanced Performance Requirement TypeC for LTE (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.3.1C |
TDD PDSCH Open Loop Spatial Multiplexing 2×2 with TM1 Interference – Enhanced Performance Requirement Type C |
Rel-12 |
C143 |
UE supporting E-UTRA TDD and Enhanced Performance Requirement TypeC for LTE (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.3.2 |
TDD PDSCH Open Loop Spatial Multiplexing 4×2 |
Rel-8 |
C02 |
UE supporting E-UTRA TDD (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.3.3_C.1 |
TDD PDSCH Open Loop Spatial Multiplexing 2×2 for eICIC (non-MBSFN ABS) |
Rel-10 |
C30 |
UEs supporting E-UTRA TDD and Feature Group Indictor 115 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.3.3_C.2 |
TDD PDSCH Open Loop Spatial Multiplexing 2×2 for eICIC (MBSFN ABS) |
Rel-10 |
C30 |
UEs supporting E-UTRA TDD and Feature Group Indictor 115 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.3.3_E.1 |
TDD PDSCH Open Loop Spatial Multiplexing 2×2 for feICIC (non-MBSFN ABS) |
Rel-11 |
C78 |
UE supporting E-UTRA TDD and CRS interference handling and ss-CCH interference handling and Feature Group Indicator 115 (UE Category >= 2) |
TBD |
||||||||||||
8.2.2.4 |
Void |
||||||||||||||||
8.2.2.4.1 |
TDD PDSCH Closed Loop Single/Multi Layer Spatial Multiplexing 2×2 |
Rel-8 only |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.4.1_1 |
TDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 2×2 (Release 9 and forward) |
Rel-9 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.4.1_E.1 |
TDD PDSCH Closed Loop Single/Multi Layer Spatial Multiplexing 2×2 for feICIC (non-MBSFN ABS) |
Rel-11 |
C78 |
UE supporting E-UTRA TDD and CRS interference handling and ss-CCH interference handling and Feature Group Indicator 115 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.4.1_H |
TDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 2×2 for 256QAM in DL |
Rel-12 |
C02h |
UE supporting E-UTRA TDD and 256QAM in DL |
|||||||||||||
8.2.2.4.2 |
TDD PDSCH Closed Loop Single/Multi Layer Spatial Multiplexing 4×2 |
Rel-8 only |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
Test execution not necessary if 8.2.2.4.2_A.1 or 8.2.2.4.2_A.2 is executed. |
|||||||||||
8.2.2.4.2_1 |
TDD PDSCH Closed Loop Single/Multi Layer Spatial Multiplexing 4×2 (Release 9 and forward) |
Rel-9 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
Test execution not necessary if 8.2.2.4.2_A.1 or 8.2.2.4.2_A.2 is executed. |
|||||||||||
8.2.2.4.2_A.1 |
TDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for CA (2DL CA) |
Rel-10 |
C110 |
UE supporting E-UTRA TDD and intra-band contiguous DL CA or inter-band DL CA (UE Category >= 5) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Test execution not necessary if 8.2.2.4.2_A.2 or 8.2.2.4.2_A.3 or 8.13.2.1.1.2 or 8.13.2.1.1.3 or 8.13.2.1.1.4 or 8.13.2.1.1.5 is executed. |
||||||||||
Rel-11 |
C109 |
UE supporting E-UTRA TDD and Intra-band non-contiguous DL CA(UE Category >= 5) |
Note 7 |
||||||||||||||
8.2.2.4.2_A.2 |
TDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for CA (3DL CA) |
Rel-10 |
C128 |
UE supporting E-UTRA TDD and 3DL with CA configurations in Table 4.1-3 (UE Category >= 5) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Test execution not necessary if 8.2.2.4.2_A.3 or 8.13.2.1.1.2 or 8.13.2.1.1.3 or 8.13.2.1.1.4 or 8.13.2.1.1.5 is executed. Note 7 |
||||||||||
Rel-11 |
C129 |
UE supporting E-UTRA TDD and 3DL with CA configurations in Table 4.1-3 (UE Category >= 5) |
|||||||||||||||
8.2.2.4.2_A.3 |
TDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for CA (4DL CA) |
Rel-11 |
C194 |
UE supporting E-UTRA TDD and 4DL CA configurations in Table 4.1-4 (UE Category >= 8) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Test execution not necessary if 8.13.2.1.1.2 or 8.13.2.1.1.3 or 8.13.2.1.1.4 or 8.13.2.1.1.5 is executed. Note 7 |
||||||||||
8.2.2.4.2_A.4 |
TDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for CA (5DL CA) |
Rel-11 |
C194a |
UE supporting E-UTRA FDD and 5DL with CA configurations in Table 4.1-5 (UE Category 8, >= 11) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
Rel-12 |
C194b |
UE supporting E-UTRA FDD and 5DL with CA configurations in Table 4.1-5 (UE Category 8, >= 11) |
|||||||||||||||
8.2.2.4.2A |
TDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 2×2 – Enhanced Performance Requirement Type C |
Rel-12 |
C143 |
UE supporting E-UTRA TDD and Enhanced Performance Requirement TypeC for LTE (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.4.3 |
TDD PDSCH Closed Loop Single Layer Spatial Multiplexing 2×2 with TM4 Interference Model – Enhanced Performance Requirement Type A |
Rel-11 |
C45 |
UE supporting E-UTRA TDD and the enhanced performance requirements type A for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.4.4 |
TDD PDSCH Closed Loop Multi-Layer Spatial Multiplexing 4×2 for Dual Connectivity |
Rel-12 |
C170 |
UE supporting E-UTRA TDD and Dual Connectivity (UE Category >= 5) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.2.4.5 |
TDD PDSCH Closed Loop Single Layer Spatial Multiplexing 2×2 with TM4 Interference Model – Enhanced Performance Requirement Type B |
Rel-12 |
C151 |
UE supporting E-UTRA TDD and the enhanced performance requirements type B for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.2.7_A.1 |
TDD Carrier aggregation with power imbalance (intra-band contiguous DL CA) |
Rel-10 |
C24 |
UE supporting E-UTRA TDD and intra-band contiguous DL CA |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.2.8.1 |
Intra-band contiguous carrier aggregation with minimum channel spacing (2DL CA) |
Rel-12 |
C24 |
UE supporting E-UTRA TDD and intra-band contiguous DL CA |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.2.8.2 |
Intra-band contiguous carrier aggregation with minimum channel spacing (3DL CA) |
Rel-12 |
C24 |
UE supporting E-UTRA TDD and intra-band contiguous DL CA |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.2.9 |
TDD PDSCH in HST-SFN scenario |
Rel-14 |
C300 |
UEs supporting E-UTRA TDD and high speed enhancement for measurement |
|||||||||||||
8.2.3.1.1.1 |
TDD FDD CA PDSCH Single Antenna Port Performance for FDD Pcell (2DL CA) |
Rel-12 |
C154 |
UE supporting E-UTRA FDD and TDD and 2DL CA with FDD as PCell (UE Category >= 5) |
TBD |
2Rx, 4Rx |
Test execution not necessary if 8.13.3.2.3 or 8.13.3.2.4 or 8.13.3.2.5 or 8.13.3.2.6 is executed. Note 7 |
||||||||||
8.2.3.1.1.2 |
TDD FDD CA PDSCH Single Antenna Port Performance for FDD PCell (3DL CA) |
Rel-12 |
C133 |
UE supporting E-UTRA FDD and TDD and 3DL CA with FDD as PCell (UE Category >= 5) |
TBD |
2Rx, 4Rx |
Test execution not necessary if 8.13.3.2.3 or 8.13.3.2.4 or 8.13.3.2.5 or 8.13.3.2.6 is executed. Note 7 |
||||||||||
8.2.3.1.1.3 |
TDD FDD CA PDSCH Single Antenna Port Performance for FDD PCell (4DL CA) |
Rel-12 |
C133a |
UE supporting E-UTRA FDD and TDD and 4DL CA with FDD as PCell (UE Category >= 8) |
TBD |
Test execution not necessary if 8.13.3.2.3 or 8.13.3.2.4 or 8.13.3.2.5 or 8.13.3.2.6 is executed. |
|||||||||||
8.2.3.1.1.4 |
TDD FDD CA PDSCH Single Antenna Port Performance for FDD PCell (5DL CA) |
Rel-12 |
C133b |
UE supporting E-UTRA FDD and TDD and 5DL CA with FDD as PCell (UE Category8, and Category 11 and onwards) |
Refer to 36.521-1 8.1.2.3 |
Test execution not necessary if 8.13.3.2.3 or 8.13.3.2.4 or 8.13.3.2.5 or 8.13.3.2.6 is executed. |
|||||||||||
8.2.3.1.1.5 |
TDD FDD CA PDSCH Single Antenna Port Performance for FDD PCell (6DL CA) |
Rel-14 |
C350 |
UE supporting E-UTRA FDD and TDD and 6DL CA with FDD as PCell (UE Category8, and Category 11 and onwards) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.1.1.6 |
TDD FDD CA PDSCH Single Antenna Port Performance for FDD PCell (7DL CA) |
Rel-14 |
C358 |
UE supporting E-UTRA FDD and TDD and 7DL CA with FDD as PCell (UE Category8, and Category 11 and onwards) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.1.2.1 |
TDD FDD CA PDSCH Single Antenna Port Performance for TDD PCell(2DL CA) |
Rel-12 |
C155 |
UE supporting E-UTRA FDD and TDD and 2DL CA with TDD as PCell (UE Category >= 5) |
TBD |
2Rx, 4Rx |
Test execution not necessary if 8.13.3.2.7 or 8.13.3.2.8 or 8.13.3.2.9 or 8.13.3.2.10 is executed. Note 7 |
||||||||||
8.2.3.1.2.2 |
TDD FDD CA PDSCH Single Antenna Port Performance for TDD PCell (3DL CA) |
Rel-12 |
C135 |
UE supporting E-UTRA FDD and TDD and 3DL CA with TDD as PCell (UE Category >= 5) |
TBD |
2Rx, 4Rx |
Test execution not necessary if 8.13.3.2.7 or 8.13.3.2.8 or 8.13.3.2.9 or 8.13.3.2.10 is executed. Note 7 |
||||||||||
8.2.3.1.2.3 |
TDD FDD CA PDSCH Single Antenna Port Performance for TDD PCell (4DL CA) |
Rel-12 |
C135a |
UE supporting E-UTRA FDD and TDD and 4DL CA with TDD as PCell (UE Category >= 8) |
TBD |
Test execution not necessary if 8.13.3.2.7 or 8.13.3.2.8 or 8.13.3.2.9 or 8.13.3.2.10 is executed. |
|||||||||||
8.2.3.1.2.4 |
TDD FDD CA PDSCH Single Antenna Port Performance for TDD PCell (5DL CA) |
Rel-12 |
C135b |
UE supporting E-UTRA FDD and TDD and 5DL CA with TDD as PCell (UE Category 8, and Category11 and onwards) |
TBD |
Test execution not necessary if 8.13.3.2.7 or 8.13.3.2.8 or 8.13.3.2.9 or 8.13.3.2.10 is executed. |
|||||||||||
8.2.3.1.2.5 |
TDD FDD CA PDSCH Single Antenna Port Performance for TDD PCell (6DL CA) |
Rel-14 |
C351 |
UE supporting E-UTRA FDD and TDD and 6DL CA with TDD as PCell (UE Category 8, and Category 11 and onwards) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.1.2.6 |
TDD FDD CA PDSCH Single Antenna Port Performance for TDD PCell (7DL CA) |
Rel-14 |
C359 |
UE supporting E-UTRA FDD and TDD and 7DL CA with TDD as PCell (UE Category8, and Category 11 and onwards) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.2.1.1 |
TDD FDD CA PDSCH Open Loop Spatial Multiplexing 2×2 for FDD PCell (2DL CA) |
Rel-12 |
C154 |
UE supporting E-UTRA FDD and TDD and 2DL CA with FDD as PCell (UE Category >= 5) |
TBD |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.2.1.2 |
TDD FDD CA PDSCH Open Loop Spatial Multiplexing 2×2 for FDD PCell (3DL CA) |
Rel-12 |
C133 |
UE supporting E-UTRA FDD and TDD and 3DL CA with FDD as PCell (UE Category >= 5) |
TBD |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.2.1.3 |
TDD FDD CA PDSCH Open Loop Spatial Multiplexing 2×2 for FDD PCell (4DL CA) |
Rel-12 |
C133a |
UE supporting E-UTRA FDD and TDD and 4DL CA with FDD as PCell (UE Category >= 8) |
Refer to 36.521-1 8.1.2.3 |
||||||||||||
8.2.3.2.1.4 |
TDD FDD CA PDSCH Open Loop Spatial Multiplexing 2×2 for FDD PCell (5DL CA) |
Rel-12 |
C133b |
UE supporting E-UTRA FDD and TDD and 5DL CA with FDD as PCell (UE Category >= 8) |
Refer to 36.521-1 8.1.2.3 |
||||||||||||
8.2.3.2.1.5 |
TDD FDD CA PDSCH Open Loop Spatial Multiplexing 2×2 for FDD PCell (6DL CA) |
Rel-14 |
C350 |
UE supporting E-UTRA FDD and TDD and 6DL CA with FDD as PCell (UE Category 8, and Category 11 and onwards) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.2.1.6 |
TDD FDD CA PDSCH Open Loop Spatial Multiplexing 2×2 for FDD PCell (7DL CA) |
Rel-14 |
C358 |
UE supporting E-UTRA FDD and TDD and 7DL CA with FDD as PCell (UE Category 8, and Category 11 and onwards) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.2.1A |
TDD FDD CA PDSCH Soft buffer management test for FDD PCell (2DL CA) |
Rel-12 |
C136 |
UE supporting E-UTRA FDD and TDD and 2DL CA with FDD as PCell (UE categories 3 and 4) |
TBD |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.2.2.1 |
TDD FDD CA PDSCH Open Loop Spatial Multiplexing 2×2 for TDD PCell (2DL CA) |
Rel-12 |
C155 |
UE supporting E-UTRA FDD and TDD and 2DL CA with TDD as PCell (UE Category >= 5) |
TBD |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.2.2.2 |
TDD FDD CA PDSCH Open Loop Spatial Multiplexing 2×2 for TDD PCell (3DL CA) |
Rel-12 |
C135 |
UE supporting E-UTRA FDD and TDD and 3DL CA with TDD PCell (UE Category >= 5) |
TBD |
2Rx, 4Rx |
|||||||||||
8.2.3.2.2.3 |
TDD FDD CA PDSCH Open Loop Spatial Multiplexing 2×2 for TDD PCell(4DL CA) |
Rel-12 |
C135a |
UE supporting E-UTRA FDD and TDD and 4DL CA with TDD as PCell (UE Category >= 8) |
Refer to 36.521-1 8.1.2.3 |
||||||||||||
8.2.3.2.2.4 |
TDD FDD CA PDSCH Open Loop Spatial Multiplexing 2×2 for TDD PCell(5DL CA) |
Rel-12 |
C135b |
UE supporting E-UTRA FDD and TDD and 5DL CA with TDD as PCell (UE Category 8, and Category11 and onwards) |
Refer to 36.521-1 8.1.2.3 |
||||||||||||
8.2.3.2.2.5 |
TDD FDD CA PDSCH Open Loop Spatial Multiplexing 2×2 for TDD PCell(6DL CA) |
Rel-14 |
C351 |
UE supporting E-UTRA FDD and TDD and 6DL CA with TDD as PCell (UE Category 8, and Category 11 and onwards) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.2.2.6 |
TDD FDD CA PDSCH Open Loop Spatial Multiplexing 2×2 for TDD PCell(7DL CA) |
Rel-14 |
C359 |
UE supporting E-UTRA FDD and TDD and 7DL CA with TDD as PCell (UE Category 8, and Category 11 and onwards) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.2.2A |
TDD FDD CA PDSCH Soft buffer management test for TDD PCell (2DL CA) |
Rel-12 |
C137 |
UE supporting E-UTRA FDD and TDD and 2DL CA with TDD PCell (UE categories 3 and 4) |
TBD |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.3.1.1 |
TDD FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for FDD PCell (2DL CA) |
Rel-12 |
C154 |
UE supporting E-UTRA FDD and TDD and 2DL CA with FDD as PCell (UE Category >= 5) |
TBD |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.3.1.2 |
TDD FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for FDD PCell (3DL CA) |
Rel-12 |
C133 |
UE supporting E-UTRA FDD and TDD and 3DL CA with FDD as PCell (UE Category >= 5) |
TBD |
||||||||||||
8.2.3.3.1.3 |
TDD FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for FDD PCell (4DL CA) |
Rel-12 |
C133a |
UE supporting E-UTRA FDD and TDD and 4DL CA with FDD as PCell (UE Category >= 8) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.3.1.4 |
TDD FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for FDD PCell (5DL CA) |
Rel-12 |
C133b |
UE supporting E-UTRA FDD and TDD and 5DL CA with FDD as PCell (UE Category >= 8) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.3.1.5 |
TDD FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for FDD PCell (6DL CA) |
Rel-14 |
C350 |
UE supporting E-UTRA FDD and TDD and 6DL CA with FDD as PCell (UE Category 8, and Category 11 and onwards) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.3.1.6 |
TDD FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for FDD PCell (7DL CA) |
Rel-14 |
C358 |
UE supporting E-UTRA FDD and TDD and 7DL CA with FDD as PCell (UE Category 8, and Category 11 and onwards) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.3.2.1 |
TDD FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for TDD PCell (2DL CA) |
Rel-12 |
C155 |
UE supporting E-UTRA FDD and TDD and 2DL CA with TDD as PCell (UE Category >=5) |
TBD |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.3.2.2 |
TDD FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for TDD PCell (3DL CA) |
Rel-12 |
C135 |
UE supporting E-UTRA FDD and TDD and 3DL CA with TDD as PCell (UE Category >= 5) |
TBD |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.3.2.3 |
TDD FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for TDD PCell (4DL CA) |
Rel-12 |
C135a |
UE supporting E-UTRA FDD and TDD and 4DL CA with TDD as PCell (UE Category >= 8) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.3.2.4 |
TDD FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for TDD PCell (5DL CA) |
Rel-12 |
C135b |
UE supporting E-UTRA FDD and TDD and 5DL CA with TDD as PCell (UE Category 8, and Category11 and onwards) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.3.2.5 |
TDD FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for TDD PCell (6DL CA) |
Rel-14 |
C351 |
UE supporting E-UTRA FDD and TDD and 6DL CA with TDD as PCell (UE Category 8, and Category 11 and onwards) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.3.3.2.6 |
TDD FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×2 for TDD PCell (7DL CA) |
Rel-14 |
C359 |
UE supporting E-UTRA FDD and TDD and 7DL CA with TDD as PCell (UE Category 8, and Category 11 and onwards) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Note 7 |
||||||||||
8.2.4.1.1 |
LAA PDSCH CA Closed Loop Spatial Multiplexing Performance-4 Tx Antenna port with FDD as Pcell |
Rel-13 |
C209 |
UE supporting E-UTRA FDD and downlink LAA with FDD as Pcell |
Each “Test Number” to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.2.4.1.2 |
LAA PDSCH CA Closed Loop Spatial Multiplexing Performance-4 Tx Antenna port with TDD as Pcell |
Rel-13 |
C210 |
UE supporting E-UTRA TDD and downlink LAA |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.3.1 |
Void |
||||||||||||||||
8.3.1.1.1_D |
FDD PDSCH Single-layer Spatial Multiplexing on antenna ports 7 or 8 without a simultaneous transmission for eDL-MIMO |
Rel-10 to Rel-14 |
C25 |
UE supporting E-UTRA FDD and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C25m |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.3.1.1.1_H |
FDD PDSCH Single-layer Spatial Multiplexing on antenna ports 7 or 8 without a simultaneous transmission for eDL-MIMO for 256QAM in DL |
Rel-12 to Rel-14 |
C25h |
UE supporting E-UTRA FDD and eDL-MIMO and 256QAM in DL and Feature Group Indicator 103 |
|||||||||||||
Rel-15 |
C25hm |
UE supporting E-UTRA FDD and eDL-MIMO and 256QAM in DL and Feature Group Indicator 103 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and eDL-MIMO and 256QAM in DL and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.3.1.1.2_D |
FDD PDSCH Single-layer Spatial Multiplexing on antenna ports 7 or 8 with a simultaneous transmission for eDL-MIMO |
Rel-10 to Rel-14 |
C25 |
UE supporting E-UTRA FDD and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C25m |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.3.1.1.3 |
FDD PDSCH Single-layer Spatial Multiplexing on antenna ports 7 or 8 with TM9 Interference Model – Enhanced Performance Requirement Type A |
Rel-11 to Rel-14 |
C40 |
UE supporting E-UTRA FDD and Feature Group Indictor 103 and supporting the enhanced performance requirements type A for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C40m |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and supporting the enhanced performance requirements type A for LTE and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and supporting the enhanced performance requirements type A for LTE and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.3.1.1.4 |
FDD PDSCH Closed Loop Single-layer Spatial Multiplexing on antenna ports 7 or 8 with TM9 Interference Model – Enhanced Performance Requirement Type B |
Rel-12 to Rel-14 |
C262 |
UE supporting E-UTRA FDD and the enhanced performance requirements type B for LTE and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C262m |
UE supporting E-UTRA FDD and the enhanced performance requirements type B for LTE and Feature Group Indicator 103 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and the enhanced performance requirements type B for LTE and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.3.1.1.6 |
FDD PDSCH Closed Loop Single-layer Spatial Multiplexing on antenna ports 7 or 8 with TM3 interference model – Enhanced Performance Requirement Type B |
Rel-12 |
C150 |
UE supporting E-UTRA FDD and the enhanced performance requirements type B for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.3.1.1.7 |
FDD PDSCH Closed Loop Single-layer Spatial Multiplexing on antenna ports 7 or 8 with TM10 serving cell configuration and TM9 interference model – Enhanced Performance Requirement Type B |
Rel-12 |
C175 |
UE supporting E-UTRA FDD, enhanced performance requirements type B and PDSCH Transmission mode 10 for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.3.1.1.9 |
FDD PDSCH Single-layer Spatial Multiplexing for FD-MIMO |
Rel-13 to Rel-14 |
C323 |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and dmrs-Enhancements-r13 |
|||||||||||||
Rel-15 |
C323m |
UE supporting E-UTRA FDD and Feature Group Indictor 103 and dmrs-Enhancements-r13 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and dmrs-Enhancements-r13 and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.3.1.1.10 |
FDD PDSCH Single-layer Spatial Multiplexing on antenna ports 7 or 8 without a simultaneous transmission for eFD-MIMO |
Rel-14 |
C361 |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and aperiodic ZP-CSI-RS reporting |
|||||||||||||
8.3.1.2.1_D |
FDD PDSCH Dual-layer Spatial Multiplexing for eDL-MIMO |
Rel-10 |
C25 |
UE supporting E-UTRA FDD and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.3.1.2.1_D_1 |
FDD PDSCH Dual-layer Spatial Multiplexing for eDL-MIMO (Release 11 and forward) |
Rel-11 to Rel-14 |
C25 |
UE supporting E-UTRA FDD and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C25m |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.3.1.2.2 |
FDD PDSCH Dual-layer Spatial Multiplexing – Enhanced Performance Requirement Type C |
Rel-12 to Rel-14 |
C144 |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and Enhanced Performance Requirement TypeC for LTE (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C144m |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and Enhanced Performance Requirement TypeC for LTE and ((2 <= UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and Enhanced Performance Requirement TypeC for LTE and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.3.1.3.1_F |
FDD PDSCH Performance with DCI format 2D, non Quasi Co-located Antenna Ports, Same Cell ID and single NZP CSI-RS resource for CoMP |
Rel-11 |
C50 |
UE supporting E-UTRA FDD and Maximum CSI processes of One on a component carrier within a band with PDSCH transmission mode 10 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.3.1.3.2_F |
FDD PDSCH Performance with DCI format 2D, non Quasi Co-located Antenna Ports, Same Cell ID and multiple NZP CSI-RS resources for CoMP |
Rel-11 |
C52 |
UE supporting E-UTRA FDD and Maximum CSI processes of Three or Four on a component carrier within a band with PDSCH transmission mode 10 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.3.1.3.3_F |
FDD PDSCH Performance with DCI format 2D, non Quasi Co-located Antenna Ports, Different Cell ID, Colliding CRS and single NZP CSI-RS resource for CoMP |
Rel-11 |
C117 |
UE supporting E-UTRA FDD and Maximum CSI processes of One, Three or Four on a component carrier within a band with PDSCH transmission mode 10 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.3.2.1.1 |
TDD PDSCH Single-layer Spatial Multiplexing on antenna port 5 (Release 8 and forward) |
Rel-8 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.3.2.1.1_1 |
TDD PDSCH Single-layer Spatial Multiplexing on antenna port 5 (Release 9 and forward) |
Rel-9 |
C16 |
UE supporting E-UTRA TDD (UE category 1) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.3.2.1.2 |
TDD PDSCH Single-layer Spatial Multiplexing on antenna port 7 or 8 without a simultaneous transmission |
Rel-9 only |
C34 |
UE supporting E-UTRA TDD and supporting enhanced dual layer TDD. |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-10 |
C02 |
UE supporting E-UTRA TDD. |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||||
8.3.2.1.2_D |
TDD PDSCH Single-layer Spatial Multiplexing on antenna ports 7 or 8 without a simultaneous transmission for eDL-MIMO |
Rel-10 to Rel-14 |
C26 |
UE supporting E-UTRA TDD and Feature Group Indicator 104 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C26m |
UE supporting E-UTRA TDD and Feature Group Indicator 104 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.3.2.1.2_H |
TDD PDSCH Single-layer Spatial Multiplexing on antenna ports 7 or 8 without a simultaneous transmission for eDL-MIMO for 256QAM in DL |
Rel-12 to Rel-14 |
C26h |
UE supporting E-UTRA TDD and 256QAM in DL and Feature Group Indicator 104 |
|||||||||||||
Rel-15 |
C26hm |
UE supporting E-UTRA TDD and 256QAM in DL and Feature Group Indicator 104 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD and 256QAM in DL and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.3.2.1.3 |
TDD PDSCH Single-layer Spatial Multiplexing on antenna port 7 or 8 with a simultaneous transmission |
Rel-9 only |
C34 |
UE supporting E-UTRA TDD and supporting enhanced dual layer TDD. |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-10 |
C02 |
UE supporting E-UTRA TDD. |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||||
8.3.2.1.3_D |
TDD PDSCH Single-layer Spatial Multiplexing on antenna ports 7 or 8 with a simultaneous transmission for eDL-MIMO |
Rel-10 to Rel-14 |
C26 |
UE supporting E-UTRA TDD and Feature Group Indicator 104 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C26m |
UE supporting E-UTRA TDD and Feature Group Indicator 104 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.3.2.1.4 |
TDD PDSCH Single-layer Spatial Multiplexing on antenna ports 7 or 8 with TM9 Interference Model – Enhanced Performance Requirement Type A |
Rel-11 to Rel-14 |
C41 |
UE supporting E-UTRA TDD and Feature Group Indictor 103 and supporting the enhanced performance requirements type A for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C41m |
UE supporting E-UTRA TDD and Feature Group Indicator 103 and supporting the enhanced performance requirements type A for LTE and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD and supporting the enhanced performance requirements type A for LTE and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.3.2.1.5 |
TDD PDSCH Closed Loop Single-layer Spatial Multiplexing on antenna ports 7 or 8 with TM9 Interference Model – Enhanced Performance Requirement Type B |
Rel-12 to Rel-14 |
C263 |
UE supporting E-UTRA TDD and the enhanced performance requirements type B for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C263m |
UE supporting E-UTRA TDD and the enhanced performance requirements type B for LTE and Feature Group Indicator 103 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD and the enhanced performance requirements type B for LTE and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.3.2.1.7 |
TDD PDSCH Closed Loop Single-layer Spatial Multiplexing on antenna ports 7 or 8 with TM3 interference model – Enhanced Performance Requirement Type B |
Rel-12 |
C151 |
UE supporting E-UTRA TDD and the enhanced performance requirements type B for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.3.2.1.8 |
TDD PDSCH Closed Loop Single-layer Spatial Multiplexing on antenna ports 7 or 8 with TM10 serving cell configuration and TM9 interference model – Enhanced Performance Requirement Type B |
Rel-12 |
C176 |
UE supporting E-UTRA TDD, enhanced performance requirements type B and PDSCH Transmission mode 10 for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.3.2.1.10 |
TDD PDSCH Single-layer Spatial Multiplexing for FD-MIMO |
Rel-13 to Rel-14 |
C324 |
UE supporting E-UTRA TDD and Feature Group Indicator 103 and dmrs-Enhancements-r13 |
|||||||||||||
Rel-15 |
C324m |
UE supporting E-UTRA TDD and Feature Group Indictor 103 and dmrs-Enhancements-r13 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD and dmrs-Enhancements-r13 and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.3.2.1.11 |
TDD PDSCH Single-layer Spatial Multiplexing on antenna ports 7 or 8 without a simultaneous transmission for eFD-MIMO |
Rel-14 |
C362 |
UE supporting E-UTRA TDD and Feature Group Indicator 104 and aperiodic ZP-CSI-RS reporting |
|||||||||||||
8.3.2.2.1 |
TDD PDSCH Dual-layer Spatial Multiplexing |
Rel-9 only |
C34 |
UE supporting E-UTRA TDD and supporting enhanced dual layer TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-10 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||||
8.3.2.2.1_D |
TDD PDSCH Dual-layer Spatial Multiplexing for eDL-MIMO |
Rel-10 |
C25a |
UE supporting E-UTRA TDD and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.3.2.2.1_D_1 |
TDD PDSCH Dual-layer Spatial Multiplexing for eDL-MIMO (Release 11 and forward) |
Rel-11 to Rel-14 |
C25a |
UE supporting E-UTRA TDD and Feature Group Indicator 103 |
TBD |
||||||||||||
Rel-15 |
C25am |
UE supporting E-UTRA TDD and Feature Group Indicator 103 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.3.2.2.2 |
TDD PDSCH Dual-layer Spatial Multiplexing – Enhanced Performance Requirement Type C |
Rel-12 |
C143 |
UE supporting E-UTRA TDD and Enhanced Performance Requirement TypeC for LTE (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.3.2.4.1_F |
TDD PDSCH Performance with DCI format 2D, non Quasi Co-located Antenna Ports, Same Cell ID and single NZP CSI-RS resource for CoMP |
Rel-11 |
C51 |
UE supporting E-UTRA TDD and Maximum CSI processes of One on a component carrier within a band with PDSCH transmission mode 10 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.3.2.4.2_F |
TDD PDSCH Performance with DCI format 2D, non Quasi Co-located Antenna Ports, Same Cell ID and multiple NZP CSI-RS resources for CoMP |
Rel-11 |
C53 |
UE supporting E-UTRA TDD and Maximum CSI processes of Three or Four on a component carrier within a band with PDSCH transmission mode 10 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.3.2.4.3_F |
TDD PDSCH Performance with DCI format 2D, non Quasi Co-located Antenna Ports, Different Cell ID, Colliding CRS and single NZP CSI-RS resource for CoMP |
Rel-11 |
C118 |
UE supporting E-UTRA TDD and Maximum CSI processes of One, Three or Four on a component carrier within a band with PDSCH transmission mode 10 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.3.3.1.1 |
LAA Dual-Layer Spatial Multiplexing with DM-RS with FDD as PCell |
Rel-13 |
C264 |
UE supporting E-UTRA FDD and downlink LAA with FDD as Pcell and TM9 on LAA cells |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.3.3.1.2 |
LAA Dual-Layer Spatial Multiplexing with DM-RS with TDD as Pcell |
Rel-13 |
C265 |
UE supporting E-UTRA TDD and downlink LAA and TM9 on LAA cells |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.4.1.1 |
FDD PCFICH/PDCCH Single-antenna Port Performance |
Rel-8 |
C01 |
UE supporting E-UTRA FDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.4.1.2 |
Void |
||||||||||||||||
8.4.1.2.1 |
FDD PCFICH/PDCCH Transmit Diversity 2×2 |
Rel-8 only |
C09 |
UE supporting E-UTRA FDD and operating bands supporting 1,4 MHz Bandwidth |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.4.1.2.1_1 |
FDD PCFICH/PDCCH Transmit Diversity 2×2 (Release 9 and forward) |
Rel-9 |
C01 |
UE supporting E-UTRA FDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.4.1.2.2 |
FDD PCFICH/PDCCH Transmit Diversity 4×2 |
Rel-8 only |
C01 |
UE supporting E-UTRA FDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.4.1.2.3_E.1 |
FDD PCFICH/PDCCH Transmit Diversity 2×2 for feICIC (non-MBSFN ABS) |
Rel-11 |
C77 |
UE supporting E-UTRA FDD and CRS interference handling and Feature Group Indicator 115 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.4.1.2.3_E.2 |
FDD PCFICH/PDCCH Transmit Diversity 2×2 for feICIC (MBSFN ABS) |
Rel-11 |
C77 |
UE supporting E-UTRA FDD and CRS interference handling and Feature Group Indicator 115 (UE) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.4.1.2.2_1 |
FDD PCFICH/PDCCH Transmit Diversity 4×2 (Release 9 and forward) |
Rel-9 |
C01 |
UE supporting E-UTRA FDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.4.1.2.3_C.1 |
FDD PCFICH/PDCCH Transmit Diversity 2×2 for eICIC (non-MBSFN ABS) |
Rel-10 |
C29 |
UE supporting E-UTRA FDD and Feature Group Indicator 115 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.4.1.2.3_C.2 |
FDD PCFICH/PDCCH Transmit Diversity 2×2 for eICIC (MBSFN ABS) |
Rel-10 |
C29 |
UEs supporting E-UTRA FDD and Feature Group Indictor 115 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.4.1.2.5 |
FDD Enhanced Downlink Control Channel Performance Type A for PCFICH/PDCCH, 2 Tx Antenna Port under Asynchronous Network |
Rel-13 |
C285 |
E-UTRA FDD UEs supporting Enhanced downlink control channel performance requirements type A |
|||||||||||||
8.4.1.2.6 |
FDD Enhanced Downlink Control Channel Performance Type A for PCFICH/PDCCH, 2 Tx Antenna Port with Non-Colliding CRS Dominant Interferer |
Rel-13 |
C285 |
E-UTRA FDD UEs supporting Enhanced downlink control channel performance requirements type A |
|||||||||||||
8.4.1.2.7 |
FDD Enhanced Downlink Control Channel Performance Type B for PCFICH/PDCCH, 2 Tx Antenna Port with Colliding CRS Dominant Interferer |
Rel-13 |
C286 |
E-UTRA FDD UEs supporting Enhanced downlink control channel performance requirements type B |
|||||||||||||
8.4.1.2.8 |
FDD Enhanced Downlink Control Channel Performance Type B for PCFICH/PDCCH, 2 Tx Antenna Port with Non-Colliding CRS Dominant Interferer |
Rel-13 |
C286 |
E-UTRA FDD UEs supporting Enhanced downlink control channel performance requirements type B |
|||||||||||||
8.4.2.1 |
TDD PCFICH/PDCCH Single-antenna Port Performance |
Rel-8 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.4.2.2 |
Void |
||||||||||||||||
8.4.2.2.1 |
TDD PCFICH/PDCCH Transmit Diversity 2×2 |
Rel-8 only |
C10 |
UE supporting E-UTRA TDD and operating bands supporting 1,4 MHz Bandwidth |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.4.2.2.1_1 |
TDD PCFICH/PDCCH Transmit Diversity 2×2 (Release 9 and forward) |
Rel-9 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.4.2.2.2 |
TDD PCFICH/PDCCH Transmit Diversity 4×2 |
Rel-8 only |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.4.2.2.2_1 |
TDD PCFICH/PDCCH Transmit Diversity 4×2 (Release 9 and forward) |
Rel-9 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.4.2.2.3_C.1 |
TDD PCFICH/PDCCH Transmit Diversity 2×2 for eICIC (non-MBSFN ABS) |
Rel-10 |
C30 |
UEs supporting E-UTRA TDD and Feature Group Indictor 115 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.4.2.2.3_C.2 |
TDD PCFICH/PDCCH Transmit Diversity 2×2 for eICIC (MBSFN ABS) |
Rel-10 |
C30 |
UEs supporting E-UTRA TDD and Feature Group Indictor 115 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.4.2.2.3_E.1 |
TDD PCFICH/PDCCH Transmit Diversity 2×2 for feICIC (non-MBSFN ABS) |
Rel-11 |
C78 |
UE supporting E-UTRA TDD and CRS interference handling and ss-CCH interference handling and Feature Group Indicator 115(UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.4.2.2.3_E.2 |
TDD PCFICH/PDCCH Transmit Diversity 2×2 for feICIC (MBSFN ABS) |
Rel-11 |
C78 |
UE supporting E-UTRA TDD and CRS interference handling and ss-CCH interference handling and Feature Group Indicator 115(UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.4.2.2.5 |
TDD Enhanced Downlink Control Channel Performance Type A for PCFICH/PDCCH, 2 Tx Antenna Port with Colliding CRS Dominant Interferer |
Rel-13 |
C287 |
E-UTRA TDD UEs supporting Enhanced downlink control channel performance requirements type A |
|||||||||||||
8.4.2.2.6 |
DD Enhanced Downlink Control Channel Performance Type A for PCFICH/PDCCH, 2 Tx Antenna Port with Non-Colliding CRS Dominant Interferer |
Rel-13 |
C287 |
E-UTRA TDD UEs supporting Enhanced downlink control channel performance requirements type A |
|||||||||||||
8.4.2.2.7 |
TDD Enhanced Downlink Control Channel Performance Type B for PCFICH/PDCCH, 2 Tx Antenna Port with Colliding CRS Dominant Interferer |
Rel-13 |
C288 |
E-UTRA TDD UEs supporting Enhanced downlink control channel performance requirements type B |
|||||||||||||
8.4.2.2.8 |
TDD Enhanced Downlink Control Channel Performance Type B for PCFICH/PDCCH, 2 Tx Antenna Port with Non-Colliding CRS Dominant Interferer |
Rel-13 |
C288 |
E-UTRA TDD UEs supporting Enhanced downlink control channel performance requirements type B |
|||||||||||||
8.4.3.1.1 |
LAA PCFICH/PDCCH Transmit Diversity 2×2 with FDD as Pcell |
Rel-13 |
C209 |
UE supporting E-UTRA FDD and downlink LAA with FDD as Pcell |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.4.3.1.2 |
LAA PCFICH/PDCCH Transmit Diversity 2×2 with TDD as Pcell |
Rel-13 |
C217 |
UE supporting E-UTRA TDD and downlink LAA |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.5.1.1 |
FDD PHICH Single-antenna Port Performance |
Rel-8 |
C01 |
UE supporting E-UTRA FDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.5.1.2 |
Void |
||||||||||||||||
8.5.1.2.1 |
FDD PHICH Transmit Diversity 2×2 |
Rel-8 only |
C09 |
UE supporting E-UTRA FDD and operating bands supporting 1,4 MHz Bandwidth |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.5.1.2.1_1 |
FDD PHICH Transmit Diversity 2×2 (Release 9 and forward) |
Rel-9 |
C01 |
UE supporting E-UTRA FDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.5.1.2.2 |
FDD PHICH Transmit Diversity 4×2 |
Rel-8 only |
C01 |
UE supporting E-UTRA FDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.5.1.2.2_1 |
FDD PHICH Transmit Diversity 4×2 (Release 9 and forward) |
Rel-9 |
C01 |
UE supporting E-UTRA FDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.5.1.2.3_C.1 |
FDD PHICH Transmit Diversity 2×2 for eICIC (non-MBSFN ABS) |
Rel-10 |
C29 |
UE supporting E-UTRA FDD and Feature Group Indicator 115 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.5.1.2.3_E.1 |
FDD PHICH Transmit Diversity 2×2 for feICIC (non-MBSFN ABS) |
Rel-11 |
C77 |
UE supporting E-UTRA FDD and CRS interference handling and Feature Group Indicator 115 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.5.1.2.5 |
FDD Enhanced Downlink Control Channel Performance Requirement Type A for PHICH- 2 Tx Antenna Ports under Asynchronous Network |
Rel-13 |
C285 |
E-UTRA FDD UEs supporting Enhanced downlink control channel performance requirements type A |
|||||||||||||
8.5.1.2.6 |
FDD Enhanced Downlink Control Channel Performance Requirement Type A for PHICH – 2 Tx Antenna Ports with Non-Colliding CRS Dominant Interferer |
Rel-13 |
C285 |
E-UTRA FDD UEs supporting Enhanced downlink control channel performance requirements type A |
|||||||||||||
8.5.1.2.7 |
FDD Enhanced Downlink Control Channel Performance Requirement Type B for PHICH – 2 Tx Antenna Ports with Colliding CRS Dominant Interferer |
Rel-13 |
C286 |
E-UTRA FDD UEs supporting Enhanced downlink control channel performance requirements type B |
|||||||||||||
8.5.1.2.8 |
FDD Enhanced Downlink Control Channel Performance Requirement Type B for PHICH – 2 Tx Antenna Ports with Non-Colliding CRS Dominant Interferer |
Rel-13 |
C286 |
E-UTRA FDD UEs supporting Enhanced downlink control channel performance requirements type B |
|||||||||||||
8.5.2.1 |
TDD PHICH Single-antenna Port Performance |
Rel-8 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.5.2.2 |
Void |
||||||||||||||||
8.5.2.2.1 |
TDD PHICH Transmit Diversity 2×2 |
Rel-8 only |
C10 |
UE supporting E-UTRA TDD and operating bands supporting 1,4 MHz Bandwidth |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.5.2.2.1_1 |
TDD PHICH Transmit Diversity 2×2 (Release 9 and forward) |
Rel-9 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.5.2.2.2 |
TDD PHICH Transmit Diversity 4×2 |
Rel-8 only |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.5.2.2.2_1 |
TDD PHICH Transmit Diversity 4×2 (Release 9 and forward) |
Rel-9 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.5.2.2.3_C.1 |
TDD PHICH Transmit Diversity 2×2 for eICIC (non-MBSFN ABS) |
Rel-10 |
C30 |
UEs supporting E-UTRA TDD and Feature Group Indictor 115 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.5.2.2.3_E.1 |
TDD PHICH Transmit Diversity 2×2 for feICIC (non-MBSFN ABS) |
Rel-11 |
C78 |
UE supporting E-UTRA TDD and CRS interference handling and ss-CCH interference handling and Feature Group Indicator 115(UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.5.2.2.5 |
TDD Enhanced Downlink Control Channel Performance Requirement Type A for PHICH- 2 Tx Antenna Ports with Colliding CRS Dominant Interfere |
Rel-13 |
C287 |
E-UTRA TDD UEs supporting Enhanced downlink control channel performance requirements type A |
|||||||||||||
8.5.2.2.6 |
TDD Enhanced Downlink Control Channel Performance Requirement Type A for PHICH – 2 Tx Antenna Ports with Non-Colliding CRS Dominant Interferer |
Rel-13 |
C287 |
E-UTRA TDD UEs supporting Enhanced downlink control channel performance requirements type A |
|||||||||||||
8.5.2.2.7 |
TDD Enhanced Downlink Control Channel Performance Requirement Type B for PHICH- 2 Tx Antenna Ports with Colliding CRS Dominant Interferer |
Rel-13 |
C288 |
E-UTRA TDD UEs supporting Enhanced downlink control channel performance requirements type B |
|||||||||||||
8.5.2.2.8 |
TDD Enhanced Downlink Control Channel Performance Requirement Type B for PHICH- 2 Tx Antenna Ports with Non-Colliding CRS Dominant Interferer |
Rel-13 |
C288 |
E-UTRA TDD UEs supporting Enhanced downlink control channel performance requirements type B |
|||||||||||||
8.7.1.1 |
FDD sustained data rate performance (Rel-9 and forward) |
Rel-9 |
C76 |
UE supporting E-UTRA FDD and not supporting 256QAM in DL (UE categories from1 to 4) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
It is not necessary for CA UEs and EPDCCH UEs to be tested in this test if 8.7.1.1_A.1 or 8.7.3.1 is executed. |
|||||||||||
8.7.1.1_1 |
FDD sustained data rate performance (Rel-10 and forward) |
Rel-10 |
C42 |
UE supporting E-UTRA FDD and not supporting 256QAM in DL (UE categories 6, 7) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
It is not necessary for CA UEs and EPDCCH UEs to be tested in this test if 8.7.1.1_A.1or 8.7.3.1 is executed. |
|||||||||||
8.7.1.1_2 |
FDD sustained data rate performance for UE category 1bis |
Rel-13 |
C145d |
UE supporting E-UTRA FDD (UE category 1bis) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.7.1.1_A.1 |
FDD Sustained data rate performance for CA (2 DL CA ) |
Rel-10 |
C107 |
UE supporting E-UTRA FDD and intra-band contiguous DL CA or inter-band DL CA and not supporting 256QAM in DL (UE category 3, 4, 6, 7, 9 and 10) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Test execution not necessary if 8.7.1.1_A.2 is executed. |
||||||||||
Rel-11 |
C93 |
UE supporting E-UTRA FDD and intra-band non-contiguous DL CA and not supporting 256QAM in DL (UE category 3, 4, 6, 7, 9 and 10) |
Note 7 |
||||||||||||||
8.7.1.1_A.2 |
FDD Sustained data rate performance for CA (3DL CA) |
Rel-10 |
C126 |
UE supporting E-UTRA FDD and 3DL with CA configurations in Table 4.1-3 and not supporting 256QAM in DL (UE category 9, 10, 11 and 12) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Test execution not necessary if 8.7.1.1_A.4 is executed |
||||||||||
Rel-10 |
C126a |
UE supporting E-UTRA FDD and 3DL with CA configurations in Table 4.1-3 and supporting at most 40MHz aggregated bandwidth and not supporting 256QAM in DL (UE category 6 and 7) |
Refer to 36.521-1 8.1.2.3 |
Note 7 |
|||||||||||||
Rel-11 |
C127 |
UE supporting E-UTRA FDD and 3DL with CA configurations in Table 4.1-3 and not supporting 256QAM in DL (UE category 9, 10, 11 and 12) |
TBD |
||||||||||||||
Rel-11 |
C127a |
UE supporting E-UTRA FDD and 3DL with CA configurations in Table 4.1-3 and supporting at most 40MHz aggregated bandwidth and not supporting 256QAM in DL (UE category 6 and 7) |
TBD |
||||||||||||||
8.7.1.1_A.4 |
FDD Sustained data rate performance for CA (4DL CA) |
Rel-11 |
C189 |
UE supporting E-UTRA FDD and 4DL with CA configurations in Table 4.1-4 and not supporting 256QAM in DL (UE category 11 and 12) |
2Rx, 4Rx |
Test execution not necessary if 8.7.1.1_A.5 is executed. Note 7 |
|||||||||||
Rel-11 |
C189a |
UE supporting E-UTRA FDD and 4DL with CA configurations in Table 4.1-4 and supporting at most 60MHz aggregated bandwidth and not supporting 256QAM in DL (UE category 9 and 10) |
|||||||||||||||
8.7.1.1_A.5 |
FDD Sustained data rate performance for CA (5DL CA) |
Rel-11 |
C266 |
UE supporting E-UTRA FDD and 5DL with CA configurations in Table 4.1-5 and not supporting 256QAM in DL (UE DL category 11,12) |
2Rx, 4Rx |
Test execution not necessary if 8.7.1.1_A.6 is executed. Note 7 |
|||||||||||
Rel-12 |
C267 |
UE supporting E-UTRA FDD and 5DL CA configurations in Table 4.1-5 and not supporting 256QAM in DL (UE DL category 11,12,15) |
|||||||||||||||
8.7.1.1_A.6 |
FDD Sustained data rate performance for CA (6DL CA) |
Rel-11 |
C330 |
UE supporting E-UTRA FDD and 6DL with CA configurations in Table 4.1-6 and not supporting 256QAM in DL (UE DL category 11,12) |
2Rx, 4Rx |
Test execution not necessary if 8.7.1.1_A.7 is executed. Note 7 |
|||||||||||
Rel-12 |
C331 |
UE supporting E-UTRA FDD and 6DL CA configurations in Table 4.1-6 and not supporting 256QAM in DL (UE DL category 11,12,15) |
|||||||||||||||
8.7.1.1_A.7 |
FDD Sustained data rate performance for CA (7DL CA) |
Rel-15 |
C343 |
UE supporting E-UTRA FDD and 7DL CA and not supporting 256QAM in DL (UE DL category 11,12,15) |
2Rx, 4Rx |
Note 7 |
|||||||||||
-8.7.1.1_H.1 |
FDD sustained data rate performance (Single Carrier) for 256QAM in DL |
Rel-12 |
C42h |
UE supporting E-UTRA FDD and 256QAM and UE DL category 13 |
Test execution not necessary if 8.7.1.1_H.2 is executed |
||||||||||||
8.7.1.1_H.2 |
FDD Sustained data rate performance for CA (2DL CA) for 256QAM in DL |
Rel-12 |
C107h |
UE supporting E-UTRA FDD and 2DL CA and 256QAM in DL (UE DL category 11, 12 and 13) |
2Rx, 4Rx |
Test execution not necessary if 8.7.1.1_H.3 is executed Note 7 |
|||||||||||
8.7.1.1_H.3 |
FDD Sustained data rate performance for CA (3DL CA) for 256QAM in DL |
Rel-12 |
C126h |
UE supporting E-UTRA FDD and 3DL CA ,and supporting 256QAM in DL (UE DL category 11, 12 and 15) |
2Rx, 4Rx |
Test execution not necessary if 8.7.1.1_H.4 is executed Note 7 |
|||||||||||
Rel-12 |
C126ha |
UE supporting E-UTRA FDD and 3DL CA ,and supporting 256QAM in DL and supporting at most 40MHz aggregated bandwidth (UE DL category 13) |
Test execution not necessary if 8.7.1.1_H.4 is executed |
||||||||||||||
8.7.1.1_H.4 |
FDD Sustained data rate performance for CA (4DL CA) for 256QAM in DL |
Rel-13 |
C189h |
UE supporting E-UTRA FDD and 4DL with CA configurations in Table 4.1-4 and supporting 256QAM in DL |
Test execution not necessary if 8.7.1.1_H.5 is executed. |
||||||||||||
8.7.1.1_H.5 |
FDD Sustained data rate performance for CA (5DL CA) for 256QAM in DL |
Rel-13 |
C266h |
UE supporting E-UTRA FDD and 5DL with CA configurations in Table 4.1-5 and supporting 256QAM in DL |
|||||||||||||
8.7.1.1_H.6 |
FDD Sustained data rate performance for CA (6DL CA) for 256QAM in DL |
Rel-13 |
C331h |
UE supporting E-UTRA FDD and 6DL with CA configurations in Table 4.1-6 and supporting 256QAM in DL |
|||||||||||||
8.7.1.1_H.7 |
FDD Sustained data rate performance for CA (7DL CA) for 256QAM in DL |
Rel-15 |
C344 |
UE supporting E-UTRA FDD and 7DL and supporting 256QAM in DL |
Test execution not necessary if 8.7.1.1_H.8 is executed |
||||||||||||
8.7.2.1 |
TDD sustained data rate performance (Rel-9 and forward) |
Rel-9 |
C111 |
UE supporting E-UTRA TDD and not supporting 256QAM in DL (UE categories from 1 to 4) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
It is not necessary for CA UEs and EPDCCH UEs to be tested in this test if 8.7.2.1_A.1 or 8.7.4.1 is executed. |
|||||||||||
8.7.2.1_1 |
TDD sustained data rate performance (Rel-10 and forward) |
Rel-10 |
C73 |
UE supporting E-UTRA TDD and not supporting 256QAM in DL (UE category 6 and 7) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
It is not necessary for CA UEs and EPDCCH UEs to be tested in this test if 8.7.2.1_A.1or 8.7.4.1 is executed. |
|||||||||||
8.7.2.1_2 |
TDD sustained data rate performance for UE category 1bis |
Rel-13 |
C156f |
UE supporting E-UTRA TDD (UE category 1bis) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.7.2.1_A.1 |
TDD sustained data rate performance for CA (2DL CA) |
Rel-10 |
C74 |
UE supporting E-UTRA TDD and intra-band contiguous DL CA or inter-band DL CA and not supporting 256QAM in DL (UE category 6, 7, 9 and 10) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Test execution not necessary if 8.7.2.1_A.2 is executed. |
||||||||||
Rel-11 |
C75 |
UE supporting E-UTRA TDD and intra-band non-contiguous DL CA and not supporting 256QAM in DL (UE category 6, 7, 9 and 10) |
Note 7 |
||||||||||||||
8.7.2.1_A.2 |
TDD Sustained data rate performance for CA (3DL CA) |
Rel-10 |
C130 |
UE supporting E-UTRA TDD and 3DL with CA configurations in Table 4.1-3 and not supporting 256QAM in DL (UE category 9, 10, 11 and 12) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Test execution not necessary if 8.7.2.1_A.3 is executed. |
||||||||||
Rel-11 |
C131 |
UE supporting E-UTRA TDD and 3DL with CA configurations in Table 4.1-3 and not supporting 256QAM in DL (UE category 9, 10, 11 and 12) |
Note 7 |
||||||||||||||
8.7.2.1_A.3 |
TDD Sustained data rate performance for CA (4DL CA) |
Rel-11 |
C213 |
UE supporting E-UTRA TDD and 4DL CA configurations in Table 4.1-3 (UE DL category 11, 12 and 15) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Test execution not necessary if 8.7.2.1_A.4 is executed. Note 7 |
||||||||||
8.7.2.1_A.5 |
TDD Sustained data rate performance for CA (5DL CA) |
Rel-11 |
C360 |
UE supporting E-UTRA TDD and 5DL CA configurations in Table 4.1-3 (UE DL category 11, 12 and 15) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Test execution not necessary if 8.7.2.1_A.6 is executed. Note 7 |
||||||||||
8.7.2.1_A.6 |
TDD Sustained data rate performance for CA (6DL CA) |
Rel-15 |
C331a |
UE supporting E-UTRA TDD and 6DL CA configurations in Table 4.1-3 (UE DL category 11, 12 and 15) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Test execution not necessary if 8.7.2.1_A.7 is executed. Note 7 |
||||||||||
8.7.2.1_A.7 |
TDD Sustained data rate performance for CA (7DL CA) |
Rel-15 |
C345 |
UE supporting E-UTRA TDD and 7DL CA (UE DL category 11, 12 and 15) |
Refer to 36.521-1 8.1.2.3 |
2Rx, 4Rx |
Test execution not necessary if 8.7.2.1_A.8 is executed. Note 7 |
||||||||||
8.7.2.1_H.1 |
TDD sustained data rate performance (Single Carrier) for 256QAM in DL |
Rel-12 |
C73h |
UE supporting E-UTRA TDD and 256QAM in DL and UE DL category 13 |
Test execution not necessary if 8.7.2.1_H.2 is executed. |
||||||||||||
8.7.2.1_H.2 |
TDD sustained data rate performance for CA (2DL CA) for 256QAM in DL |
Rel-12 |
C74h |
UE supporting E-UTRA TDD and 2DL CA, and supporting 256QAM in DL (UE DL category 11, 12 and 13) |
2Rx, 4Rx |
Test execution not necessary if 8.7.2.1_H.3 is executed. Note 7 |
|||||||||||
8.7.2.1_H.3 |
TDD Sustained data rate performance for CA (3DL CA) for 256QAM in DL |
Rel-12 |
C130h |
UE supporting E-UTRA TDD and 3DL CA and supporting 256QAM in DL (UE DL Category 11, 12 and 15) |
2Rx, 4Rx |
Test execution not necessary if 8.7.2.1_H.4 is executed. Note 7 |
|||||||||||
8.7.2.1_H.4 |
TDD Sustained data rate performance for CA (4DL CA) for 256QAM in DL |
Rel-13 |
C213h |
UE supporting E-UTRA TDD and 4DL CA and supporting 256QAM in DL (UE DL Category 11, 12,15 and 16) |
2Rx, 4Rx |
Test execution not necessary if 8.7.2.1_H.5 is executed. Note 7 |
|||||||||||
8.7.2.1_H.5 |
TDD Sustained data rate performance for CA (5DL CA) for 256QAM in DL |
Rel-14 |
C332 |
UE supporting E-UTRA TDD and 5DL CA and supporting 256QAM in DL (UE DL Category 16) |
2Rx, 4Rx |
Note 7 |
|||||||||||
8.7.2.1_H.6 |
TDD Sustained data rate performance for CA (6DL CA) for 256QAM in DL |
Rel-15 |
C331ha |
UE supporting E-UTRA TDD and 6DL CA and supporting 256QAM in DL (UE DL Category 16) |
2Rx, 4Rx |
Test execution not necessary if 8.7.2.1_H.7 is executed. Note 7 |
|||||||||||
8.7.2.1_H.7 |
TDD Sustained data rate performance for CA (7DL CA) for 256QAM in DL |
Rel-15 |
C346 |
UE supporting E-UTRA TDD and 7DL CA and supporting 256QAM in DL (UE DL Category 16) |
2Rx, 4Rx |
Test execution not necessary if 8.7.2.1_H.8 is executed. Note 7 |
|||||||||||
8.7.3.1 |
FDD sustained data rate performance for EPDCCH scheduling |
Rel-11 |
C55 |
UE supporting E-UTRA FDD and EPDCCH |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.7.4.1 |
TDD sustained data rate performance for EPDCCH scheduling |
Rel-11 |
C56 |
UE supporting E-UTRA TDD and EPDCCH |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.7.5.1.1 |
TDD FDD CA Sustained data rate performance for FDD PCell (2DL CA) |
Rel-12 |
C138 |
UE supporting E-UTRA FDD and TDD and 2DL CA with FDD as PCell and not supporting 256QAM in DL (UE category 3, 4, 6, 7, 9 and 10) |
TBD |
2Rx, 4Rx |
Test execution not necessary if 8.7.5.1.2 is executed. Note 7 |
||||||||||
8.7.5.1.2 |
TDD FDD CA Sustained data rate performance for FDD PCell (3DL CA) |
Rel-12 |
C139 |
UE supporting E-UTRA FDD and TDD and 3DL CA with FDD as PCell and not supporting 256QAM in DL (UE category 9, 10, 11 and 12) |
TBD |
2Rx, 4Rx |
Test execution not necessary if 8.7.5.1.3 is executed. Note 7 |
||||||||||
8.7.5.1.3 |
TDD FDD CA Sustained data rate performance for FDD PCell (4DL CA) |
Rel-12 |
C139a |
UE supporting E-UTRA FDD and TDD and 4DL CA with FDD as PCell and not supporting 256QAM in DL (UE category 11 and 12) |
TBD |
2Rx, 4Rx |
Test execution not necessary if 8.7.5.1.4 is executed. Note 7 |
||||||||||
8.7.5.1.4 |
TDD FDD CA Sustained data rate performance for FDD PCell (5DL CA) |
Rel-12 |
C139b |
UE supporting E-UTRA FDD and TDD and 5DL CA with FDD as PCell and not supporting 256QAM in DL (UE DL category 15) |
TBD |
2Rx, 4Rx |
Note 7 |
||||||||||
8.7.5.1.5 |
TDD FDD CA Sustained data rate performance for FDD PCell (6DL CA) |
Rel-12 |
C139c |
UE supporting E-UTRA FDD and TDD and 6DL CA with FDD as PCell and not supporting 256QAM in DL (UE DL category 15) |
TBD |
2Rx, 4Rx |
Note 7 |
||||||||||
8.7.5.1.6 |
TDD FDD CA Sustained data rate performance for FDD PCell (7DL CA) |
Rel-12 |
C369 |
UE supporting E-UTRA FDD and TDD and 7DL CA with FDD as PCell and not supporting 256QAM in DL (UE DL category 15) |
TBD |
2Rx, 4Rx |
Note 7 |
||||||||||
8.7.5.1_H.1 |
TDD FDD CA Sustained data rate performance for FDD PCell (2DL CA) for 256QAM in DL |
Rel-12 |
C138h |
UE supporting E-UTRA FDD and TDD and 2DL TDD-FDD CA with FDD as PCell and supporting 256QAM in DL (UE DL category 11, 12 and 13) |
2Rx, 4Rx |
Test execution not necessary if 8.7.5.1_H.2 is executed. Note 7 |
|||||||||||
8.7.5.1_H.2 |
TDD FDD CA Sustained data rate performance for FDD PCell (3DL CA) for 256QAM in DL |
Rel-12 |
C139h |
UE supporting E-UTRA FDD and TDD and 3DL TDD-FDD CA with FDD as PCell and supporting 256QAM in DL (UE DL Category 11, 12 and 15) |
2Rx, 4Rx |
Test execution not necessary if 8.7.5.1_H.3 is executed. Note 7 |
|||||||||||
8.7.5.1_H.3 |
TDD FDD CA Sustained data rate performance for FDD PCell (4DL CA) for 256QAM in DL |
Rel-12 |
C139ha |
UE supporting E-UTRA FDD and TDD and 4DL TDD-FDD CA with FDD as PCell and supporting 256QAM in DL |
Test execution not necessary if 8.7.5.1_H.4 is executed. |
||||||||||||
8.7.5.1_H.4 |
TDD FDD CA Sustained data rate performance for FDD PCell (5DL CA) for 256QAM in DL |
Rel-12 |
C139hb |
UE supporting E-UTRA FDD and TDD and 5DL TDD-FDD CA with FDD as PCell and supporting 256QAM in DL |
|||||||||||||
8.7.5.1_H.5 |
TDD FDD CA Sustained data rate performance for FDD PCell (6DL CA) for 256QAM in DL |
Rel-12 |
C139hc |
UE supporting E-UTRA FDD and TDD and 6DL TDD-FDD CA with FDD as PCell and supporting 256QAM in DL |
|||||||||||||
8.7.5.2.1 |
TDD FDD CA Sustained data rate performance for TDD PCell (2DL CA) |
Rel-12 |
C140 |
UE supporting E-UTRA FDD and TDD and 2DL CA with TDD as PCell and not supporting 256QAM in DL (UE category 3, 4, 6, 7, 9 and 10) |
TBD |
2Rx, 4Rx |
Test execution not necessary if 8.7.5.2.2 is executed. Note 7 |
||||||||||
8.7.5.2.2 |
TDD FDD CA Sustained data rate performance for TDD PCell (3DL CA) |
Rel-12 |
C141 |
UE supporting E-UTRA FDD and TDD and 3DL CA with TDD as PCell and not supporting 256QAM in DL (UE category 9, 10, 11 and 12) |
TBD |
2Rx, 4Rx |
Test execution not necessary if 8.7.5.2.3 is executed. Note 7 |
||||||||||
8.7.5.2.3 |
TDD FDD CA Sustained data rate performance for TDD PCell (4DL CA) |
Rel-12 |
C141a |
UE supporting E-UTRA FDD and TDD and 4DL CA with TDD as PCell and not supporting 256QAM in DL (UE category 11 and 12) |
TBD |
2Rx, 4Rx |
Test execution not necessary if 8.7.5.2.4 is executed. Note 7 |
||||||||||
8.7.5.2.4 |
TDD FDD CA Sustained data rate performance for TDD PCell (5DL CA) |
Rel-12 |
C141b |
UE supporting E-UTRA FDD and TDD and 5DL CA with TDD as PCell and not supporting 256QAM in DL (UE category 15) |
TBD |
2Rx, 4Rx |
Note 7 |
||||||||||
8.7.5.2.5 |
TDD FDD CA Sustained data rate performance for TDD PCell (6DL CA) |
Rel-12 |
C141c |
UE supporting E-UTRA FDD and TDD and 6DL CA with TDD as PCell and not supporting 256QAM in DL (UE category 15) |
TBD |
2Rx, 4Rx |
Note 7 |
||||||||||
8.7.5.2.6 |
TDD FDD CA Sustained data rate performance for TDD PCell (7DL CA) |
Rel-12 |
C370 |
UE supporting E-UTRA FDD and TDD and 7DL CA with TDD as PCell and not supporting 256QAM in DL (UE category 15) |
TBD |
2Rx, 4Rx |
Note 7 |
||||||||||
8.7.5.2_H.1 |
TDD FDD CA Sustained data rate performance for TDD PCell (2DL CA) for 256QAM in DL |
Rel-12 |
C140h |
UE supporting E-UTRA FDD and TDD and 2DL TDD-FDD CA with TDD as PCell and supporting 256QAM in DL (UE DL Category 11, 12 and 13) |
2Rx, 4Rx |
Test execution not necessary if 8.7.5.2_H.2 is executed. Note 7 |
|||||||||||
8.7.5.2_H.2 |
TDD FDD CA Sustained data rate performance for TDD PCell (3DL CA) for 256QAM in DL |
Rel-12 |
C141h |
UE supporting E-UTRA FDD and TDD and 3DL TDD-FDD CA with TDD as PCell and supporting 256QAM in DL (UE DL Category 11, 12 and 15) |
2Rx, 4Rx |
Test execution not necessary if 8.7.5.2_H.3 is executed. Note 7 |
|||||||||||
8.7.5.2_H.4 |
TDD FDD CA Sustained data rate performance for TDD PCell (5DL CA) for 256QAM in DL |
Rel-12 |
C141hb |
UE supporting E-UTRA FDD and TDD and 5DL TDD-FDD CA with TDD as PCell and supporting 256QAM in DL (UE DL Category 16) |
2Rx, 4Rx |
Note 7 |
|||||||||||
8.7.5.2_H.5 |
TDD FDD CA Sustained data rate performance for TDD PCell (6DL CA) for 256QAM in DL |
Rel-12 |
C142h |
UE supporting E-UTRA FDD and TDD and 6DL TDD-FDD CA with TDD as PCell and supporting 256QAM in DL (UE DL Category 16) |
2Rx, 4Rx |
Note 7 |
|||||||||||
8.7.6.1 |
FDD sustained data rate performance for Dual Connectivity 64QAM |
Rel-12 |
C171 |
UE supporting E-UTRA FDD and Dual Connectivity and not supporting 256QAM in DL (UE Category 3, 4, 6, 7, 9, and 10) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
8.7.6.2 |
FDD sustained data rate performance for Dual Connectivity 256QAM |
Rel-12 |
C173 |
UE supporting E-UTRA FDD and Dual Connectivity and supporting 256QAM in DL |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
8.7.7.1 |
TDD sustained data rate performance for Dual Connectivity 64QAM |
Rel-12 |
C172 |
UE supporting E-UTRA TDD and Dual Connectivity and not supporting 256QAM in DL (UE Category 6, 7, 9, and 10) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
8.7.7.2 |
TDD sustained data rate performance for Dual Connectivity 256QAM |
Rel-12 |
C174 |
UE supporting E-UTRA TDD and Dual Connectivity and supporting 256QAM in DL |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
8.7.9.2 |
FDD sustained data rate performance for 4 layer MIMO (single carrier) |
Rel-10 |
C226 |
UE supporting E-UTRA FDD with 4Rx antenna ports and 4-layer spatial multiplexing (UE Category 6 and 7 and UE DL category 13) |
One "Test Number" to be performed. The selected band shall lead to the largest equivalent aggregated bandwidth Note 3 supported by UE. |
Test execution not necessary if another test case in clause 8.7.9 is executed, where larger equivalent aggregated bandwidth can be achieved. |
|||||||||||
8.7.9.3 |
FDD sustained data rate performance for 4 layer MIMO (2DL CA) |
Rel-10 |
C227 |
UE supporting 2DL FDD CA with 4Rx antenna ports and 4-layer spatial multiplexing and intra-band contiguous DL CA or inter-band DL CA (UE Category 9, 10, 11 and 12 and UE DL category 9, 10, 11, 12 and 15) |
One "Test Number" to be performed. The selected CA configuration shall lead to the largest equivalent aggregated bandwidth Note 3 supported by UE. |
Test execution not necessary if another test case in clause 8.7.9 is executed, where larger equivalent aggregated bandwidth can be achieved. |
|||||||||||
Rel-11 |
C228 |
UE supporting 2DL FDD CA with 4Rx antenna ports and 4-layer spatial multiplexing and intra-band non-contiguous DL CA (UE Category 9, 10, 11 and 12 and UE DL category 9, 10, 11, 12 and 15) |
|||||||||||||||
8.7.9.4 |
FDD sustained data rate performance for 4 layer MIMO (3DL CA) |
Rel-10 |
C229 |
UE supporting 3DL FDD CA with 4Rx antenna ports and 4-layer spatial multiplexing and 3DL with CA configurations in Table 4.1-3 (UE Category 11 and 12 and UE DL category 11, 12, 15, 16 and 18) |
One "Test Number" to be performed, in a chosen CA configuration, which leads to the largest equivalent aggregated bandwidth Note 3 supported by UE. |
Test execution not necessary if another test case in clause 8.7.9 is executed, where larger equivalent aggregated bandwidth can be achieved. |
|||||||||||
Rel-11 |
C230 |
UE supporting 3DL FDD CA with 4Rx antenna ports and 4-layer spatial multiplexing and 3DL with CA configurations in Table 4.1-3 and 4Rx antenna ports and 4-layer spatial multiplexing (UE Category 11 and 12 and UE DL category 11, 12, 15, 16 and 18) |
|||||||||||||||
8.7.9.5 |
FDD sustained data rate performance for 4 layer MIMO (4DL CA) |
Rel-11 |
C236 |
UE supporting 4DL FDD CA with 4Rx antenna ports and 4-layer spatial multiplexing and 4DL with CA configurations in Table 4.1-4 (UE DL category 15, 16, 18 and 19) |
One "Test Number" to be performed, in a chosen CA configuration, which leads to the largest equivalent aggregated bandwidth Note 3 supported by UE. |
Test execution not necessary if another test case in clause 8.7.9 is executed, where larger equivalent aggregated bandwidth can be achieved. |
|||||||||||
8.7.9.6 |
FDD sustained data rate performance for 4 layer MIMO (5DL CA) |
Rel-11 |
C237 |
UE supporting 5DL FDD CA with 4Rx antenna ports and 4-layer spatial multiplexing and 5DL with CA configurations in Table 4.1-5 (UE DL category 15, 16, 18 and 19) |
One "Test Number" to be performed, in a chosen CA configuration, which leads to the largest equivalent aggregated bandwidth Note 3 supported by UE. |
Test execution not necessary if another test case in clause 8.7.9 is executed, where larger equivalent aggregated bandwidth can be achieved. |
|||||||||||
Rel-12 |
C238 |
UE supporting 5DL FDD CA with 4Rx antenna ports and 4-layer spatial multiplexing and 5DL with CA configurations in Table 4.1-5 (UE DL category 15, 16, 18 and 19) |
|||||||||||||||
8.7.10.2 |
TDD sustained data rate performance for 4 layer MIMO (single carrier) |
Rel-10 |
C239 |
UE supporting E-UTRA TDD with 4Rx antenna ports and 4-layer spatial multiplexing (UE Category 6 and 7 and UE DL category 13) |
One "Test Number" to be performed, in a chosen CA configuration, which leads to the largest equivalent aggregated bandwidth Note 3 supported by UE. |
Test execution not necessary if another test case in clause 8.7.10 is executed, where larger equivalent aggregated bandwidth can be achieved. |
|||||||||||
8.7.10.3 |
TDD sustained data rate performance for 4 layer MIMO (2DL CA) |
Rel-10 |
C240 |
UE supporting 2DL TDD CA with 4Rx antenna ports and 4-layer spatial multiplexing and intra-band contiguous DL CA or inter-band DL CA (UE Category 9, 10, 11 and 12 and UE DL category 9, 10, 11, 12 and 15) |
One "Test Number" to be performed, in a chosen CA configuration, which leads to the largest equivalent aggregated bandwidth Note 3 supported by UE. |
Test execution not necessary if another test case in clause 8.7.10 is executed, where larger equivalent aggregated bandwidth can be achieved. |
|||||||||||
Rel-11 |
C241 |
UE supporting 2DL TDD CA with 4Rx antenna ports and 4-layer spatial multiplexing and intra-band non-contiguous DL CA (UE Category 9, 10, 11 and 12 and UE DL category 9, 10, 11, 12 and 15) |
|||||||||||||||
8.7.10.4 |
TDD sustained data rate performance for 4 layer MIMO (3DL CA) |
Rel-10 |
C242 |
UE supporting 3DL TDD CA with 4Rx antenna ports and 4-layer spatial multiplexing and 3DL with CA configurations in Table 4.1-3 (UE Category 11 and 12 and UE DL category 11, 12, 15, 16 and 18) |
One "Test Number" to be performed, in a chosen CA configuration, which leads to the largest equivalent aggregated bandwidth Note 3 supported by UE. |
Test execution not necessary if another test case in clause 8.7.10 is executed, where larger equivalent aggregated bandwidth can be achieved. |
|||||||||||
Rel-11 |
C243 |
UE supporting 3DL TDD CA with 4Rx antenna ports and 4-layer spatial multiplexing and 3DL with CA configurations in Table 4.1-3 (UE Category 11 and 12 and UE DL category 11, 12, 15, 16 and 18) |
|||||||||||||||
8.7.10.5 |
TDD sustained data rate performance for 4 layer MIMO (4DL CA) |
Rel-11 |
C244 |
UE supporting 4DL TDD CA with 4Rx antenna ports and 4-layer spatial multiplexing and 4DL with CA configurations in Table 4.1-4 (UE DL category 16, 18 and 19) |
One "Test Number" to be performed, in a chosen CA configuration, which leads to the largest equivalent aggregated bandwidth Note 3 supported by UE. |
Test execution not necessary if another test case in clause 8.7.10 is executed, where larger equivalent aggregated bandwidth can be achieved. |
|||||||||||
8.7.10.6 |
TDD sustained data rate performance for 4 layer MIMO (5DL CA) |
Rel-11 |
C245 |
UE supporting 5DL TDD CA with 4Rx antenna ports and 4-layer spatial multiplexing and 5DL with CA configurations in Table 4.1-5 (UE DL category 18 and 19) |
One "Test Number" to be performed, in a chosen CA configuration, which leads to the largest equivalent aggregated bandwidth Note 3 supported by UE. |
Test execution not necessary if another test case in clause 8.7.10 is executed, where larger equivalent aggregated bandwidth can be achieved. |
|||||||||||
Rel-12 |
C246 |
UE supporting 5DL TDD CA with 4Rx antenna ports and 4-layer spatial multiplexing and 5DL with CA configurations in Table 4.1-5 (UE DL category 18 and 19) |
|||||||||||||||
8.7.11.2 |
TDD FDD CA sustained data rate performance for 4 layer MIMO (2DL CA) |
Rel-12 |
C247 |
UE supporting 2DL FDD-TDD CA with 4Rx antenna ports and 4-layer spatial multiplexing (UE Category 9, 10, 11 and 12 and UE DL category 9, 10, 11, 12 and 15) |
One "Test Number" to be performed, in a chosen CA configuration, which leads to the largest equivalent aggregated bandwidth Note 3 supported by UE. |
Test execution not necessary if another test case in clause 8.7.11 is executed, where larger equivalent aggregated bandwidth can be achieved. |
|||||||||||
8.7.11.3 |
TDD FDD CA sustained data rate performance for 4 layer MIMO (3DL CA) |
Rel-12 |
C248 |
UE supporting 3DL FDD-TDD CA with 4Rx antenna ports and 4-layer spatial multiplexing (UE Category 11 and 12 and UE DL category 11, 12, 15, 16 and 18) |
One "Test Number" to be performed, in a chosen CA configuration, which leads to the largest equivalent aggregated bandwidth Note 3 supported by UE. |
Test execution not necessary if another test case in clause 8.7.11 is executed, where larger equivalent aggregated bandwidth can be achieved. |
|||||||||||
8.7.11.4 |
TDD FDD CA sustained data rate performance for 4 layer MIMO (4DL CA) |
Rel-12 |
C249 |
UE supporting 4DL FDD-TDD CA with 4Rx antenna ports and 4-layer spatial multiplexing (UE DL category 15, 16, 18 and 19) |
One "Test Number" to be performed, in a chosen CA configuration, which leads to the largest equivalent aggregated bandwidth Note 3 supported by UE. |
Test execution not necessary if another test case in clause 8.7.11 is executed, where larger equivalent aggregated bandwidth can be achieved. |
|||||||||||
8.7.11.5 |
TDD FDD CA sustained data rate performance for 4 layer MIMO (5DL CA) |
Rel-12 |
C250 |
UE supporting 5DL FDD-TDD CA with 4Rx antenna ports and 4-layer spatial multiplexing (UE DL category 16, 18 and 19) |
One "Test Number" to be performed, in a chosen CA configuration, which leads to the largest equivalent aggregated bandwidth Note 3 supported by UE. |
Test execution not necessary if another test case in clause 8.7.11 is executed, where larger equivalent aggregated bandwidth can be achieved. |
|||||||||||
8.7.12.1.2.1 |
LAA sustained data rate performance with FDD PCell with 2DL CA (2Rx) |
Rel-13 |
C209 |
UE supporting E-UTRA FDD and downlink LAA with FDD as Pcell |
One "Test Number" to be performed, in a chosen CA configuration, which leads to the largest |
||||||||||||
8.7.12.1.2.2 |
LAA sustained data rate performance with FDD PCell for 4 Layer MIMO (2DL CA) |
Rel-13 |
C328 |
UE supporting E-UTRA FDD and downlink LAA with FDD as Pcell abd 4-layer spatial multiplexing |
One "Test Number" to be performed, in a chosen CA configuration, which leads to the largest |
||||||||||||
8.7.12.2.2.1 |
LAA sustained data rate performance with TDD PCell with 2DL CA (2Rx) |
Rel-13 |
C210 |
UE supporting E-UTRA TDD and downlink LAA |
One "Test Number" to be performed, in a chosen CA configuration, which leads to the largest |
||||||||||||
8.7.12.2.2.2 |
LAA sustained data rate performance with TDD PCell for 4 Layer MIMO (2DL CA) |
Rel-13 |
C329 |
UE supporting E-UTRA TDD and downlink LAA with FDD as Pcell abd 4-layer spatial multiplexing |
One "Test Number" to be performed, in a chosen CA configuration, which leads to the largest |
||||||||||||
8.8.1.1 |
FDD distributed EPDCCH performance |
Rel-11 |
C55 |
UE supporting E-UTRA FDD and EPDCCH |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.8.1.2 |
TDD distributed EPDCCH performance |
Rel-11 |
C56 |
UE supporting E-UTRA TDD and EPDCCH |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.8.2.1 |
FDD localized EPDCCH performance with TM9 |
Rel-11 to Rel-14 |
C91 |
UE supporting E-UTRA FDD and EPDCCH and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C91m |
UE supporting E-UTRA FDD and EPDCCH and Feature Group Indicator 103 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and EPDCCH and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.8.2.2 |
TDD localized EPDCCH performance with TM9 |
Rel-11 to Rel-14 |
C92 |
UE supporting E-UTRA TDD and EPDCCH and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C92m |
UE supporting E-UTRA TDD and EPDCCH and Feature Group Indicator 103 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD and EPDCCH and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.8.3.1 |
FDD localized EPDCCH transmission with TM10 Type B quasi co-location type |
Rel-11 |
C57 |
UE supporting E-UTRA FDD and EPDCCH and Multiple CSI processes on a component carrier within a band with PDSCH transmission mode 10 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.8.3.2 |
TDD localized EPDCCH transmission with TM10 Type B quasi co-location type |
Rel-11 |
C58 |
UE supporting E-UTRA TDD and EPDCCH and Multiple CSI processes on a component carrier within a band with PDSCH transmission mode 10 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.8.4.1 |
FDD Enhanced Downlink Control Channel Performance Requirements Type A for EDPCCH – Localized Transmission with CRS Interference Model |
Rel-13 |
C289 |
E-UTRA FDD UEs supporting Enhanced downlink control channel performance requirements type A |
|||||||||||||
8.8.4.2 |
TDD Enhanced Downlink Control Channel Performance Requirements Type A for EDPCCH – Localized Transmission with CRS Interference Model |
Rel-13 |
C290 |
E-UTRA TDD UEs supporting Enhanced downlink control channel performance requirements type A |
|||||||||||||
8.8.5.1 |
TDD Enhanced Downlink Control Channel Performance Requirements Type A for EDPCCH – Distributed Transmission with TM9 Interference Model |
Rel-13 |
C290 |
E-UTRA TDD UEs supporting Enhanced downlink control channel performance requirements type A |
|||||||||||||
8.8.6.1 |
FDD Enhanced Downlink Control Channel Performance Type A for EDPCCH- Distributed Transmission with TM3 Interference Model |
Rel-13 |
C289 |
E-UTRA FDD UEs supporting Enhanced downlink control channel performance requirements type A |
|||||||||||||
8.9.1.1.1 |
Transmit diversity performance for UE category 0 (Cell-Specific Reference Symbols) |
Rel-12 |
C145 |
UE supporting E-UTRA FDD (UE category 0) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.9.1.1.1_1 |
FDD PDSCH Transmit Diversity 4×1 for UE category 1bis |
Rel-13 |
C145d |
UE supporting E-UTRA FDD (UE category 1bis) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.9.1.1.2 |
FDD closed-loop spatial multiplexing performance (Cell-Specific Reference Symbols) |
Rel-12 |
C145 |
UE supporting E-UTRA FDD (UE category 0) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.9.1.1.2_1 |
FDD PDSCH Closed Loop Single Layer Spatial Multiplexing 4×1 for UE Category 1bis |
Rel-13 |
C145d |
UE supporting E-UTRA FDD (UE category 1bis) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.9.1.1.3 |
FDD PDSCH Single-layer Spatial Multiplexing on antenna ports 7 or 8 for UE category 0 |
Rel-12 |
C157 |
UE supporting E-UTRA FDD (UE category 0) and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.9.1.1.3_1 |
FDD PDSCH Single-layer Spatial Multiplexing on antenna ports 7 or 8 for UE category 1bis |
Rel-13 |
C157a |
UE supporting E-UTRA FDD (UE category 1bis) and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.9.1.2.1 |
TDD PDSCH Transmit Diversity for UE category 0 |
Rel-12 |
C156 |
UE supporting E-UTRA TDD (UE category 0) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.9.1.2.1_1 |
TDD PDSCH Transmit Diversity for UE category 1bis |
Rel-13 |
C156f |
UE supporting E-UTRA TDD (UE category 1bis) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.9.1.2.2 |
TDD closed-loop spatial multiplexing performance (Cell-Specific Reference Symbols) |
Rel-12 |
C145 |
UE supporting E-UTRA FDD (UE category 0) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.9.1.2.2_1 |
TDD PDSCH Closed Loop Single Layer Spatial Multiplexing 2×1 for UE Category 1bis |
Rel-13 |
C156f |
UE supporting E-UTRA TDD (UE category 1bis) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.9.1.2.3 |
TDD PDSCH Single-layer Spatial Multiplexing on antenna ports 7 or 8 for UE category 0 |
Rel-12 |
C158 |
UE supporting E-UTRA TDD (UE category 0) and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.9.1.2.3_1 |
TDD PDSCH Single-layer Spatial Multiplexing on antenna ports 7 or 8 for UE category 1bis |
Rel-13 |
C158a |
UE supporting E-UTRA TDD (UE category 1bis) and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.9.2.1.1 |
FDD PHICH Transmit Diversity for UE category 0 |
Rel-12 |
C145 |
UE supporting E-UTRA FDD (UE category 0) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.9.2.1.1_1 |
FDD PHICH Transmit Diversity for UE category 1bis |
Rel-13 |
C145d |
UE supporting E-UTRA FDD (UE category 1bis) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.9.2.2.1 |
TDD PHICH Transmit Diversity for UE category 0 |
Rel-12 |
C156 |
UE supporting E-UTRA TDD (UE category 0) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.9.2.2.1_1 |
TDD PHICH Transmit Diversity for UE category 1bis |
Rel-13 |
C156f |
UE supporting E-UTRA TDD (UE category 1bis) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.10.1.1.1 |
FDD PDSCH Transmit Diversity 2×4 |
Rel-10 |
C113b |
UE supporting E-UTRA FDD with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.1.1.2 |
FDD PDSCH Open Loop Spatial Multiplexing 2×4 |
Rel-10 |
C113b |
UE supporting E-UTRA FDD with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.1.1.3 |
FDD PDSCH Closed Loop Single Layer Spatial Multiplexing 2×4 with TM4 Interference Model – Enhanced Performance Requirement Type A |
Rel-11 |
C113d |
UE supporting E-UTRA FDD with 4Rx antenna ports and the enhanced performance requirements type A for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.1.1.4 |
FDD PDSCH Closed Loop Spatial Multiplexing 4×4 |
Rel-10 |
C113b |
UE supporting E-UTRA FDD with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.1.1.5 |
FDD PDSCH Single-layer Spatial Multiplexing 2×4 on antenna ports 7 or 8 with TM9 interference model – Enhanced Performance Requirement Type A |
Rel-11 to Rel-14 |
C113e |
UE supporting E-UTRA FDD with 4Rx antenna ports and the enhanced performance requirements type A for LTE and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
Rel-15 |
C113em |
UE supporting E-UTRA FDD with 4Rx antenna ports and the enhanced performance requirements type A for LTE and Feature Group Indicator 103 and (UE Category < 8 and 8 < UE Category < 11 and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD with 4Rx antenna ports and the enhanced performance requirements type A for LTE and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.10.1.1.6 |
FDD Dual-Layer Spatial Multiplexing 2×4 (User-Specific Reference Symbols) |
Rel-10 to Rel-14 |
C113c |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
Rel-15 |
C113cm |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and 4Rx antenna ports and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and 4Rx antenna ports (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.10.1.1.7 |
FDD Open-loop spatial multiplexing, 3 Layer Multiplexing with 4 Tx Antenna Ports |
Rel-10 |
C220 |
UE supporting E-UTRA FDD with 4Rx antenna ports and 3-layer spatial multiplexing |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.1.1.8 |
FDD Closed-loop spatial multiplexing performance, 4 Layers spatial multiplexing 4 Tx antennas |
Rel-10 |
C220 |
UE supporting E-UTRA FDD with 4Rx antenna ports and 4-layer spatial multiplexing |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.1.1.9 |
FDD 4 Layer Spatial Multiplexing (User-Specific Reference Symbols) |
Rel-10 to Rel-14 |
C113c |
UE supporting E-UTRA FDD and eDL-MIMO and Feature Group Indicator 103 and 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
Rel-15 |
C113cm |
UE supporting E-UTRA FDD and eDL-MIMO and Feature Group Indicator 103 and 4Rx antenna ports and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and eDL-MIMO and 4Rx antenna ports (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.10.1.2.1 |
TDD PDSCH Transmit Diversity 2×4 |
Rel-10 |
C198 |
UE supporting E-UTRA TDD with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.1.2.2 |
TDD PDSCH Open Loop Spatial Multiplexing 2×4 |
Rel-10 |
C198 |
UE supporting E-UTRA TDD with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.1.2.3 |
TDD PDSCH Closed Loop Single Layer Spatial Multiplexing 2×4 with TM4 Interference Model – Enhanced Performance Requirement Type A |
Rel-11 |
C198 a |
UE supporting E-UTRA TDD with 4Rx antenna ports and the enhanced performance requirements type A for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.1.2.4 |
TDD PDSCH Closed Loop Spatial Multiplexing 4×4 |
Rel-10 |
C198 |
UE supporting E-UTRA TDD with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.1.2.5 |
TDD PDSCH Single-layer Spatial Multiplexing 2×4 on antenna ports 7 or 8 with TM9 interference model – Enhanced Performance Requirement Type A |
Rel-11 |
C198c |
UE supporting E-UTRA TDD with 4Rx antenna ports and the enhanced performance requirements type A for LTE and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.1.2.6 |
TDD Dual-Layer Spatial Multiplexing 2×4 (User-Specific Reference Symbols) |
Rel-10 |
C198b |
UE supporting E-UTRA TDD with 4Rx antenna ports and UE Category 2 or higher and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.1.2.7 |
TDD Open-loop spatial multiplexing, 3 Layer Multiplexing with 4 Tx Antenna Ports |
Rel-10 |
C235 |
UE supporting E-UTRA TDD with 4Rx antenna ports and 3-layer spatial multiplexing |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.1.2.8 |
TDD Closed-loop spatial multiplexing performance, 4 Layers spatial multiplexing 4 Tx antennas |
Rel-10 |
C235 |
UE supporting E-UTRA TDD with 4Rx antenna ports and 4-layer spatial multiplexing |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.1.2.9 |
TDD 4 Layer Spatial Multiplexing (User-Specific Reference Symbols) |
Rel-10 to Rel-14 |
C183 |
UE supporting E-UTRA TDD and UE Category ≥ 5 and Feature Group Indicator 103 and 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
Rel-15 |
C183m |
UE supporting E-UTRA TDD and Feature Group Indicator 103 with 4Rx antenna ports and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13)), or UE supporting E-UTRA TDD with 4Rx antenna ports and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.10.2.1.1 |
FDD PCFICH/PDCCH Single-antenna Port Performance 1×4 |
Rel-10 |
C113b |
UE supporting E-UTRA FDD with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.2.1.2 |
FDD PCFICH/PDCCH Transmit Diversity Performance 2×4 |
Rel-10 |
C113b |
UE supporting E-UTRA FDD with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.2.1.3 |
FDD PCFICH/PDCCH Transmit Diversity Performance 4×4 |
Rel-10 |
C113b |
UE supporting E-UTRA FDD with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.2.2.1 |
TDD PCFICH/PDCCH Single-antenna Port Performance 1×4 |
Rel-10 |
C184 |
UE supporting E-UTRA TDD with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.2.2.2 |
TDD PCFICH/PDCCH Transmit Diversity Performance 2×4 |
Rel-10 |
C184 |
UE supporting E-UTRA TDD with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.2.2.3 |
TDD PCFICH/PDCCH Transmit Diversity Performance 4×4 |
Rel-10 |
C184 |
UE supporting E-UTRA TDD with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.3.1.1 |
FDD PHICH Single-antenna Port Performance 1×4 |
Rel-10 |
C113b |
UE supporting E-UTRA FDD with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.3.1.2 |
FDD PHICH Transmit Diversity Performance 2×4 |
Rel-10 |
C113b |
UE supporting E-UTRA FDD with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.3.1.3 |
FDD PHICH Transmit Diversity Performance 4×4 |
Rel-10 |
C113b |
UE supporting E-UTRA FDD with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.3.2.1 |
TDD PHICH Single-antenna Port Performance 1×4 |
Rel-10 |
C184 |
UE supporting E-UTRA TDD with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.3.2.2 |
TDD PHICH Transmit Diversity Performance 2×4 |
Rel-10 |
C184 |
UE supporting E-UTRA TDD with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.3.2.3 |
TDD PHICH Transmit Diversity Performance 4×4 |
Rel-10 |
C184 |
UE supporting E-UTRA TDD with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.4.1.1 |
FDD distributed EPDCCH performance 2×4 |
Rel-10 |
C164 |
UE supporting E-UTRA FDD and EPDCCH with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.4.1.2 |
TDD distributed EPDCCH performance 2×4 |
Rel-10 |
C165 |
UE supporting E-UTRA TDD and EPDCCH with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
8.10.4.2.1 |
FDD localized EPDCCH performance with TM9 2×4 |
Rel-10 to Rel-14 |
C166 |
UE supporting E-UTRA FDD and EPDCCH and Feature Group Indicator 103 with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
Rel-15 |
C166m |
UE supporting E-UTRA FDD and EPDCCH and Feature Group Indicator 103 with 4Rx antenna ports and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and EPDCCH with 4Rx antenna ports and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.10.4.2.2 |
TDD localized EPDCCH performance with TM9 2×4 |
Rel-10 to Rel-14 |
C167 |
UE supporting E-UTRA TDD and EPDCCH and Feature Group Indicator 103 with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
Rel-15 |
C167m |
UE supporting E-UTRA TDD and EPDCCH and Feature Group Indicator 103 with 4Rx antenna ports and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD and EPDCCH with 4Rx antenna ports (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.11.1.1.1 |
FDD and half-duplex FDD Closed-loop spatial multiplexing performance for UE supporting CE |
Rel-13 |
C145e |
UE supporting E-UTRA FDD and UE category M1 and TM6 in CEModeA |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-14 |
C145f |
UE supporting E-UTRA FDD and UE category M2 and TM6 in CEModeA |
|||||||||||||||
8.11.1.1.2 |
FDD and half-duplex FDD PDSCH Single-layer Spatial Multiplexing on antenna ports 7 or 8 for UE supporting CE |
Rel-13 |
C145g |
UE supporting E-UTRA FDD and UE category M1 and TM9 in CEModeA |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-14 |
C145h |
UE supporting E-UTRA FDD and UE category M2 and TM9 in CEModeA |
|||||||||||||||
8.11.1.1.3.1 |
FDD and half-duplex FDD PDSCH Transmit Diversity 2×1 for UE category M1 |
Rel-13 |
C145a |
UE supporting E-UTRA FDD and UE category M1 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.11.1.1.3.1_1 |
FDD and half-duplex FDD PDSCH Transmit Diversity 2×1 for UE category M1 (CEmodeB) |
Rel-13 |
C156c |
UE supporting E-UTRA FDD and (UE category M1 and CEModeB) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.11.1.2.1 |
TDD Closed-loop spatial multiplexing performance for CE UE in CE Mode A (Cell-Specific Reference Symbols) |
Rel-13 |
C156q |
UE supporting E-UTRA TDD and UE category M1 and TM6 in CEModeA |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-14 |
C156h |
UE supporting E-UTRA TDD and UE category M2 and TM6 in CEModeA |
|||||||||||||||
8.11.1.2.2 |
TDD PDSCH Single-layer Spatial Multiplexing on antenna ports 7 or 8 for CE UE in CE Mode A |
Rel-13 |
C156e |
UE supporting E-UTRA TDD and UE category M1 and TM9 in CEModeA |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-14 |
C156i |
UE supporting E-UTRA TDD and UE category M2 and TM9 in CEModeA |
|||||||||||||||
8.11.1.2.3.1 |
TDD PDSCH Transmit Diversity for UE category M1 |
Rel-13 |
C156b |
UE supporting E-UTRA TDD and UE category M1 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.11.1.2.3.1_1 |
TDD PDSCH Transmit Diversity for UE category M1 (CEModeB) |
Rel-13 |
C156d |
UE supporting E-UTRA TDD and UE category M1 and CEModeB |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.11.1.2.3.2 |
TDD PDSCH 2 Tx Antenna Port supporting wideband transmission for UE category M2 |
Rel-14 |
C316a |
UE supporting E-UTRA TDD and UE category M2 and CEModeA |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.11.1.2.3.2_1, |
TDD PDSCH 2 Tx Antenna Port supporting wideband transmission for UE category M2 (CEModeB) |
Rel-14 |
C316b |
UE supporting E-UTRA TDD and UE category M2 and CEModeB |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.11.2.1.1 |
FDD demodulation of MPDCCH in CE Mode A |
Rel-13 |
C145b |
UE supporting E-UTRA FDD and (UE category M1 or CEModeA) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-14 |
C314 |
UE supporting E-UTRA FDD and (UE category M2 or CEModeA) |
|||||||||||||||
8.11.2.1.2 |
FDD and half-duplex FDD demodulation of MPDCCH in CE Mode B |
Rel-13 |
C156c |
UE supporting E-UTRA FDD and (UE category M1 and CEModeB) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-14 |
C315 |
UE supporting E-UTRA FDD and (UE category M1 and CEModeB) |
|||||||||||||||
8.11.2.2.1 |
TDD demodulation of MPDCCH in CE Mode A |
Rel-13 |
C156b |
UE supporting E-UTRA TDD and (UE category M1 or UE category M2 or CEModeA) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-14 |
C316 |
UE supporting E-UTRA TDD and (UE category M2 or CEModeA) |
|||||||||||||||
8.11.2.2.2 |
TDD demodulation of MPDCCH in CE Mode B |
Rel-13 |
C156d |
UE supporting E-UTRA TDD and (UE category M1 or UE category M2 and CEModeB) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-14 |
C317 |
UE supporting E-UTRA TDD and (UE category M1 and CEModeB) |
|||||||||||||||
8.12.1.1.1 |
Demodulation of NPDSCH (Cell-Specific Reference Symbols) in In-band mode for Category NB1 and NB2 |
Rel-13 |
C347 |
UE supporting NB-IoT FDD |
Each "Test Number" to be performed once, in a chosen band |
||||||||||||
8.12.1.1.2 |
Demodulation of NPDSCH (Cell-Specific Reference Symbols) in standalone and Guard-band mode for category NB1 and NB2 |
Rel-13 |
C347 |
UE supporting NB-IoT FDD |
Each "Test Number" to be performed once, in a chosen band |
||||||||||||
8.12.1.1.3 |
Demodulation of NPDSCH (Cell-Specific Reference Symbols) in standalone for NB2 |
Rel-14 |
C298 |
UE supporting E-UTRA FDD and category NB2 |
Each “Test Number” to be performed once, in a chosen band |
||||||||||||
8.12.2.1.1 |
Demodulation of NPDCCH single-antenna performance for category NB1 and NB2 |
Rel-13 |
C347 |
UE supporting NB-IoT FDD |
Each "Test Number" to be performed once, in a chosen band |
||||||||||||
8.12.2.1.2 |
Demodulation of NPDCCH in In-band mode Transmit Diversity performance for Category NB1 and NB2 |
Rel-13 |
C347 |
UE supporting NB-IoT FDD |
Each "Test Number" to be performed once, in a chosen band |
||||||||||||
8.13.1.1.3 |
FDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×4 with 256QAM (2DL CA) |
Rel-10 |
C278 |
UE supporting E-UTRA FDD and intra-band contiguous DL CA or inter-band DL CA and 4 Rx antenna ports and 256QAM in DL (UE Category >= 5) |
|||||||||||||
Rel-11 |
C279 |
UE supporting E-UTRA FDD and intra-band non-contiguous DL CA and 4 Rx antenna ports and 256QAM in DL (UE Category >= 5) |
|||||||||||||||
8.13.1.1.4 |
FDD PDSCH Closed Loop Four-Layer Spatial Multiplexing for CA (2DL CA) |
Rel-11 |
C280 |
UE supporting E-UTRA FDD and 2DL CA with 4Rx antenna ports and 4-layer spatial multiplexing (UE Category >= 5) |
|||||||||||||
8.13.1.1.1.2 |
FDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×4 (2DL CA) |
Rel-10 |
C253 |
UE supporting E-UTRA FDD and intra-band contiguous DL CA or inter-band DL CA (UE Category >= 5) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.3 |
Test execution not necessary if 8.13.1.1.1.3 or 8.13.1.1.1.4 or 8.13.1.1.1.5 is executed. |
|||||||||||
Rel-11 |
C254 |
UE supporting E-UTRA FDD and intra-band non-contiguous DL CA (UE Category >= 5) and 4Rx antenna ports |
|||||||||||||||
8.13.1.1.1.3 |
FDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×4 (3DL CA) |
Rel-10 |
C255 |
UE supporting E-UTRA FDD and 3DL with CA configurations in Table 4.1-3 (UE Category >= 5) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.6.5 |
Test execution not necessary if 8.13.1.1.1.4 or 8.13.1.1.1.5 is executed. |
|||||||||||
Rel-11 |
C256 |
UE supporting E-UTRA FDD and 3DL with CA configurations in Table 4.1-3 (UE Category >= 5) and 4Rx antenna ports |
|||||||||||||||
8.13.1.1.1.4 |
FDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×4 (4DL CA) |
Rel-11 |
C257 |
UE supporting E-UTRA FDD and 4DL with CA configurations in Table 4.1-4 (UE Category >= 5) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.6.5 |
Test execution not necessary if 8.13.1.1.1.5 is executed. |
|||||||||||
8.13.1.1.1.5 |
FDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×4 (5DL CA) |
Rel-11 |
C258 |
UE supporting E-UTRA FDD and 5DL with CA configurations in Table 4.1-5 (UE Category 8, >= 11) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.6.5 |
||||||||||||
Rel-12 |
C259 |
UE supporting E-UTRA FDD and 5DL with CA configurations in Table 4.1-5 (UE Category 8, >= 11) and 4Rx antenna ports |
|||||||||||||||
8.13.1.2.2 |
FDD Dual-Layer Spatial Multiplexing 2×4 (User-Specific Reference Symbols) (2DL CA) |
Rel-10 |
C253 |
UE supporting E-UTRA FDD and intra-band contiguous DL CA or inter-band DL CA (UE Category >= 5) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.6.5 |
Test execution not necessary if 8.13.1.2.3 or 8.13.1.2.4 or 8.13.1.2.5 is executed. |
|||||||||||
Rel-11 |
C254 |
UE supporting E-UTRA FDD and intra-band non-contiguous DL CA (UE Category >= 5) and 4Rx antenna ports |
|||||||||||||||
8.13.1.2.3 |
FDD Dual-Layer Spatial Multiplexing 2×4 (User-Specific Reference Symbols) (3DL CA) |
Rel-10 |
C255 |
UE supporting E-UTRA FDD and 3DL with CA configurations in Table 4.1-3 (UE Category >= 5) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.6.5 |
Test execution not necessary if 8.13.1.2.4 or 8.13.1.2.5 is executed. |
|||||||||||
Rel-11 |
C256 |
UE supporting E-UTRA FDD and 3DL with CA configurations in Table 4.1-3 (UE Category >= 5) and 4Rx antenna ports |
|||||||||||||||
8.13.1.2.4 |
FDD Dual-Layer Spatial Multiplexing 2×4 (User-Specific Reference Symbols) (4DL CA) |
Rel-11 |
C257 |
UE supporting E-UTRA FDD and 4DL with CA configurations in Table 4.1-4 (UE Category >= 5) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.6.5 |
Test execution not necessary if 8.13.1.2.5 is executed. |
|||||||||||
8.13.1.2.5 |
FDD Dual-Layer Spatial Multiplexing 2×4 (User-Specific Reference Symbols) (5DL CA) |
Rel-11 |
C258 |
UE supporting E-UTRA FDD and 5DL with CA configurations in Table 4.1-5 (UE Category 8, >= 11) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.6.5 |
||||||||||||
Rel-12 |
C259 |
UE supporting E-UTRA FDD and 5DL with CA configurations in Table 4.1-5 (UE Category 8, >= 11) and 4Rx antenna ports |
|||||||||||||||
8.13.1.3.1 |
FDD PDSCH Closed Loop Single Layer Spatial Multiplexing 2×4 with TM4 Interference Model – Enhanced Performance Requirement Type A (2DL CA) |
Rel-11 |
C281 |
UE supporting E-UTRA FDD and 2DL CA with 4Rx antenna ports and the enhanced performance requirements type A (UE Category >= 5) |
|||||||||||||
8.13.1.4.1 |
FDD PDSCH Single-layer Spatial Multiplexing 2×4 on antenna ports 7 or 8 with TM9 Interference Model – Enhanced Performance Requirement Type A (2DL CA) |
Rel-11to Rel-14 |
C282 |
UE supporting E-UTRA FDD and 2DL CA with 4Rx antenna ports and the enhanced performance requirements type A and Feature Group Indictor 103 (UE Category >= 5) |
|||||||||||||
Rel-15 |
C282m |
UE supporting E-UTRA FDD and 2DL CA with 4Rx antenna ports and the enhanced performance requirements type A and Feature Group Indictor 103 and ((5 <= UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and 2DL CA with 4Rx antenna ports and the enhanced performance requirements type A and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.13.2.1.1.2 |
TDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×4 (2DL CA) |
Rel-10 |
C291 |
UE supporting E-UTRA TDD and intra-band contiguous DL CA or inter-band DL CA (UE Category >= 5) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.3 |
Test execution not necessary if 8.13.2.1.1.3 or 8.13.2.1.1.4 or 8.13.2.1.1.5 is executed. |
|||||||||||
Rel-11 |
C292 |
UE supporting E-UTRA TDD and intra-band non-contiguous DL CA (UE Category >= 5) and 4Rx antenna ports |
|||||||||||||||
8.13.2.1.1.3 |
TDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×4 (3DL CA) |
Rel-10 |
C293 |
UE supporting E-UTRA TDD and 3DL with CA configurations in Table 4.1-3 (UE Category >= 5) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.6.5 |
Test execution not necessary if 8.13.2.1.1.4 or 8.13.2.1.1.5 is executed. |
|||||||||||
Rel-11 |
C294 |
UE supporting E-UTRA TDD and 3DL with CA configurations in Table 4.1-3 (UE Category >= 5) and 4Rx antenna ports |
|||||||||||||||
8.13.2.1.1.4 |
TDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×4 (4DL CA) |
Rel-11 |
C295 |
UE supporting E-UTRA TDD and 4DL with CA configurations in Table 4.1-4 (UE Category >= 5) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.6.5 |
Test execution not necessary if 8.13.2.1.1.5 is executed. |
|||||||||||
8.13.2.1.1.5 |
TDD PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×4 (5DL CA) |
Rel-11 |
C296 |
UE supporting E-UTRA TDD and 5DL with CA configurations in Table 4.1-5 (UE Category 8, >= 11) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.6.5 |
||||||||||||
Rel-12 |
C297 |
UE supporting E-UTRA TDD and 5DL with CA configurations in Table 4.1-5 (UE Category 8, >= 11) and 4Rx antenna ports |
|||||||||||||||
8.13.2.2.2 |
TDD Dual-Layer Spatial Multiplexing 2×4 (User-Specific Reference Symbols) (2DL CA) |
Rel-10 |
C291 |
UE supporting E-UTRA TDD and intra-band contiguous DL CA or inter-band DL CA (UE Category >= 5) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.6.5 |
Test execution not necessary if 8.13.2.2.3 or 8.13.2.2.4 or 8.13.2.2.5 is executed. |
|||||||||||
Rel-11 |
C292 |
UE supporting E-UTRA TDD and intra-band non-contiguous DL CA (UE Category >= 5) and 4Rx antenna ports |
|||||||||||||||
8.13.2.2.3 |
TDD Dual-Layer Spatial Multiplexing 2×4 (User-Specific Reference Symbols) (3DL CA) |
Rel-10 |
C293 |
UE supporting E-UTRA TDD and 3DL with CA configurations in Table 4.1-3 (UE Category >= 5) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.6.5 |
Test execution not necessary if 8.13.2.2.4 or 8.13.2.2.5 is executed. |
|||||||||||
Rel-11 |
C294 |
UE supporting E-UTRA TDD and 3DL with CA configurations in Table 4.1-3 (UE Category >= 5) and 4Rx antenna ports |
|||||||||||||||
8.13.2.2.4 |
TDD Dual-Layer Spatial Multiplexing 2×4 (User-Specific Reference Symbols) (4DL CA) |
Rel-11 |
C295 |
UE supporting E-UTRA TDD and 4DL with CA configurations in Table 4.1-4 (UE Category >= 5) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.6.5 |
Test execution not necessary if 8.13.2.2.5 is executed. |
|||||||||||
8.13.2.2.5 |
TDD Dual-Layer Spatial Multiplexing 2×4 (User-Specific Reference Symbols) (5DL CA) |
Rel-11 |
C296 |
UE supporting E-UTRA TDD and 5DL with CA configurations in Table 4.1-5 (UE Category 8, >= 11) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.6.5 |
||||||||||||
Rel-12 |
C297 |
UE supporting E-UTRA TDD and 5DL with CA configurations in Table 4.1-5 (UE Category 8, >= 11) and 4Rx antenna ports |
|||||||||||||||
8.13.2.3.1 |
TDD PDSCH Closed Loop Single Layer Spatial Multiplexing 2×4 with TM4 Interference Model – Enhanced Performance Requirement Type A (2DL CA) |
Rel-11 |
C283 |
UE supporting E-UTRA TDD and 2DL CA with 4Rx antenna ports and the enhanced performance requirements type A (UE Category >= 5) |
|||||||||||||
8.13.2.4.1 |
TDD PDSCH Single-layer Spatial Multiplexing 2×4 on antenna ports 7 or 8 with TM9 Interference Model – Enhanced Performance Requirement Type A (2DL CA) |
Rel-11 to Rel-14 |
C284 |
UE supporting E-UTRA TDD and 2DL CA with 4Rx antenna ports and the enhanced performance requirements type A and Feature Group Indictor 103 (UE Category >= 5) |
|||||||||||||
Rel-15 |
C284m |
UE supporting E-UTRA TDD and 2DL CA with 4Rx antenna ports and the enhanced performance requirements type A and Feature Group Indictor 103 and ((5 <= UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD and 2DL CA with 4Rx antenna ports and the enhanced performance requirements type A and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.13.3.1.1.2 |
TDD-FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×4 for FDD PCell (2DL CA) |
Rel-12 to Rel-14 |
C306 |
UE supporting E-UTRA FDD and TDD and 2DL CA with FDD as PCell (UE Category >= 5) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.3 |
Test execution not necessary if 8.13.3.1.1.3 or 8.13.3.1.1.4 or 8.13.3.1.1.5 is executed. |
|||||||||||
Rel-15 |
C234m |
UE supporting E-UTRA FDD and TDD and 2DL CA with 4Rx antenna ports and Feature Group Indicator 103 and the enhanced performance requirements type A for LTE and TDD as PCell and ((5 <= UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and TDD and 2DL CA with 4Rx antenna ports and the enhanced performance requirements type A for LTE and TDD as PCell and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
8.13.3.1.1.3 |
TDD-FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×4 for FDD PCell (3DL CA) |
Rel-12 |
C307 |
UE supporting E-UTRA FDD and TDD and 3DL CA with FDD as PCell (UE Category >= 5) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.3 |
Test execution not necessary if 8.13.3.1.1.4 or 8.13.3.1.1.5 is executed. |
|||||||||||
8.13.3.1.1.4 |
TDD-FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×4 for FDD PCell (4DL CA) |
Rel-12 |
C308 |
UE supporting E-UTRA FDD and TDD and 4DL CA with FDD as PCell (UE Category >= 8) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.3 |
Test execution not necessary if 8.13.3.1.1.5 is executed. |
|||||||||||
8.13.3.1.1.5 |
TDD-FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×4 for FDD PCell (5DL CA) |
Rel-12 |
C309 |
UE supporting E-UTRA FDD and TDD and 5DL CA with FDD as PCell (UE Category >= 8) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.3 |
||||||||||||
8.13.3.1.2.2 |
TDD-FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×4 for TDD PCell (2DL CA) |
Rel-12 |
C310 |
UE supporting E-UTRA FDD and TDD and 2DL CA with TDD as PCell (UE Category >=5) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.3 |
Test execution not necessary if 8.13.3.1.2.3 or 8.13.3.1.2.4 or 8.13.3.1.2.5 is executed. |
|||||||||||
8.13.3.1.2.3 |
TDD-FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×4 for TDD PCell (3DL CA) |
Rel-12 |
C311 |
UE supporting E-UTRA FDD and TDD and 3DL CA with TDD as PCell (UE Category >= 5) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.3 |
Test execution not necessary if 8.13.3.1.2.4 or 8.13.3.1.2.5 is executed. |
|||||||||||
8.13.3.1.2.4 |
TDD-FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×4 for TDD PCell (4DL CA) |
Rel-12 |
C312 |
UE supporting E-UTRA FDD and TDD and 4DL CA with TDD as PCell (UE Category >= 8) |
Refer to 36.521-1 8.1.2.3 |
Test execution not necessary if 8.13.3.1.2.5 is executed. |
|||||||||||
8.13.3.1.2.5 |
TDD-FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×4 for TDD PCell (5DL CA) |
Rel-12 |
C322 |
UE supporting E-UTRA FDD and TDD and 5DL CA with TDD as PCell (UE Category 8, and Category11 and onwards) and 4Rx antenna ports |
Refer to 36.521-1 8.1.2.3 |
||||||||||||
8.13.3.2.3 |
TDD-FDD CA Dual-Layer Spatial Multiplexing 2×4 for FDD PCell (User-Specific Reference Symbols) (2DL CA) |
Rel-12 |
C154 |
UE supporting E-UTRA FDD and TDD and 2DL CA with FDD as PCell (UE Category >= 5) |
Refer to 36.521-1 8.1.2.3 |
Test execution not necessary if 8.13.3.2.4 or 8.13.3.2.5 or 8.13.3.2.6 is executed. |
|||||||||||
8.13.3.2.4 |
TDD-FDD CA Dual-Layer Spatial Multiplexing 2×4 for FDD PCell (User-Specific Reference Symbols) (3DL CA) |
Rel-12 |
C133 |
UE supporting E-UTRA FDD and TDD and 3DL CA with FDD as PCell (UE Category >= 5) |
Refer to 36.521-1 8.1.2.3 |
Test execution not necessary if 8.13.3.2.5 or 8.13.3.2.6 is executed. |
|||||||||||
8.13.3.2.5 |
TDD-FDD CA Dual-Layer Spatial Multiplexing 2×4 for FDD PCell (User-Specific Reference Symbols) (4DL CA) |
Rel-12 |
C133a |
UE supporting E-UTRA FDD and TDD and 4DL CA with FDD as PCell (UE Category >= 8) |
Refer to 36.521-1 8.1.2.3 |
Test execution not necessary if 8.13.3.2.6 is executed. |
|||||||||||
8.13.3.2.6 |
TDD-FDD CA Dual-Layer Spatial Multiplexing 2×4 for FDD PCell (User-Specific Reference Symbols) (5DL CA) |
Rel-12 |
C133b |
UE supporting E-UTRA FDD and TDD and 5DL CA with FDD as PCell (UE Category >= 8) |
Refer to 36.521-1 8.1.2.3 |
||||||||||||
8.13.3.2.7 |
TDD-FDD CA Dual-Layer Spatial Multiplexing 2×4 for TDD PCell (User-Specific Reference Symbols) (2DL CA) |
C155 |
UE supporting E-UTRA FDD and TDD and 2DL CA with TDD as PCell (UE Category >=5) |
Refer to 36.521-1 8.1.2.3 |
Test execution not necessary if 8.13.3.2.8 or 8.13.3.2.9 or 8.13.3.2.10 is executed. |
||||||||||||
8.13.3.2.8 |
TDD-FDD CA Dual-Layer Spatial Multiplexing 2×4 for TDD PCell (User-Specific Reference Symbols) (3DL CA) |
C135 |
UE supporting E-UTRA FDD and TDD and 3DL CA with TDD as PCell (UE Category >= 5) |
Refer to 36.521-1 8.1.2.3 |
Test execution not necessary if 8.13.3.2.9 or 8.13.3.2.10 is executed. |
||||||||||||
8.13.3.2.9 |
TDD-FDD CA Dual-Layer Spatial Multiplexing 2×4 for TDD PCell (User-Specific Reference Symbols) (4DL CA) |
C135a |
UE supporting E-UTRA FDD and TDD and 4DL CA with TDD as PCell (UE Category >= 8) |
Refer to 36.521-1 8.1.2.3 |
Test execution not necessary if 8.13.3.2.10 is executed. |
||||||||||||
8.13.3.2.10 |
TDD-FDD CA Dual-Layer Spatial Multiplexing 2×4 for TDD PCell (User-Specific Reference Symbols) (5DL CA) |
C135b |
UE supporting E-UTRA FDD and TDD and 5DL CA with TDD as PCell (UE Category 8, and Category11 and onwards) |
Refer to 36.521-1 8.1.2.3 |
|||||||||||||
8.13.3.3.1 |
TDD-FDD CA PDSCH Closed Loop Single Layer Spatial Multiplexing 2×4 with TM4 Interference Model-Enhanced Performance Requirement Type A for FDD Pcell (2DL CA) |
Rel-12 |
C231 |
UE supporting E-UTRA FDD and TDD and 2DL CA with 4Rx antenna ports and the enhanced performance requirements type A for LTE and FDD as PCell (UE Category >=5) |
|||||||||||||
8.13.3.3.2 |
TDD-FDD CA PDSCH Closed Loop Single Layer Spatial Multiplexing 2×4 with TM4 Interference Model-Enhanced Performance Requirement Type A for TDD Pcell (2DL CA) |
Rel-12 |
C232 |
UE supporting E-UTRA FDD and TDD and 2DL CA with 4Rx antenna ports and the enhanced performance requirements type A for LTE and TDD as PCell (UE Category >=5) |
|||||||||||||
8.13.3.4.1 |
TDD-FDD CA PDSCH Single-layer Spatial Multiplexing 2×4 on antenna ports 7 or 8 with TM9 Interference Model – Enhanced Performance Requirement Type A for FDD PCell (2DL CA) |
Rel-12 |
C233 |
UE supporting E-UTRA FDD and TDD and 2DL CA with 4Rx antenna ports and Feature Group Indictor 103 and the enhanced performance requirements type A for LTE and FDD as PCell (UE Category >=5) |
|||||||||||||
8.13.3.4.2 |
TDD-FDD CA PDSCH Single-layer Spatial Multiplexing 2×4 on antenna ports 7 or 8 with TM9 Interference Model – Enhanced Performance Requirement Type A for TDD PCell (2DL CA) |
Rel-12 |
C234 |
UE supporting E-UTRA FDD and TDD and 2DL CA with 4Rx antenna ports and Feature Group Indictor 103 and the enhanced performance requirements type A for LTE and TDD as PCell (UE Category >=5) |
|||||||||||||
8.13.3.6.1 |
TDD-FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×4 with 256QAM for FDD PCell (2DL CA) |
Rel-12 |
C251 |
UE supporting E-UTRA FDD and TDD and 2DL CA with 4Rx antenna ports and 256QAM in DL and FDD as Pcell(UE Category >=5) |
|||||||||||||
8.13.3.6.2 |
TDD-FDD CA PDSCH Closed Loop Multi Layer Spatial Multiplexing 4×4 with 256QAM for TDD PCell (2DL CA) |
Rel-12 |
C252 |
UE supporting E-UTRA FDD and TDD and 2DL CA with 4Rx antenna ports and 256QAM in DL and TDD as Pcell(UE Category >=5) |
|||||||||||||
8.14.1.1.1 |
FDD slot/subslot-PDSCH Open Loop Spatial Multiplexing Performance (Cell-Specific Reference Symbols) |
Rel-15 |
C354 |
UE supporting E-UTRA FDD and slot/subslot TTI (UE categories >=2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.14.1.1.2 |
FDD slot/subslot-PDSCH Closed Loop Spatial Multiplexing Performance (User-Specific Reference Signals) |
Rel-15 |
C355 |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and slot/subslot TTI |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.14.1.2.1 |
TDD slot-PDSCH Open Loop Spatial Multiplexing Performance (Cell-Specific Reference Symbols) |
Rel-15 |
C356 |
UE supporting E-UTRA TDD and slot TTI |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.14.1.2.2 |
TDD slot-PDSCH Closed Loop Spatial Multiplexing Performance (User-Specific Reference Signals) |
Rel-15 |
C355a |
UE supporting E-UTRA TDD and Feature Group Indicator 103 and slot TTI |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.14.2.1 |
FDD SPDCCH Transmit diversity performance |
Rel-15 |
C355 |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and slot/subslot TTI |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
8.14.2.2 |
TDD SPDCCH Transmit diversity performance |
Rel-15 |
C355a |
UE supporting E-UTRA TDD and Feature Group Indicator 103 and slot TTI |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Reporting of Channel State Information |
|||||||||||||||||
9.2.1.1 |
FDD CQI Reporting under AWGN conditions – PUCCH 1-0 |
Rel-8 |
C01 |
UE supporting E-UTRA FDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.2.1.2 |
TDD CQI Reporting under AWGN conditions – PUCCH 1-0 |
Rel-8 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.2.1.3_C.1 |
FDD CQI Reporting under AWGN conditions – PUCCH 1-0 for eICIC (non-MBSFN ABS) |
Rel-10 |
C29 |
UE supporting E-UTRA FDD and Feature Group Indicator 115 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.2.1.4_C.1 |
TDD CQI Reporting under AWGN conditions – PUCCH 1-0 for eICIC (non-MBSFN ABS) |
Rel-10 |
C30 |
UEs supporting E-UTRA TDD and Feature Group Indictor 115 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.2.1.5_E.1 |
FDD CQI Reporting under AWGN conditions – PUCCH 1-0 for feICIC (non-MBSFN ABS) |
Rel-11 |
C77 |
UE supporting E-UTRA FDD and CRS interference handling and Feature Group Indicator 115 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.2.1.6_E.1 |
TDD CQI Reporting under AWGN conditions – PUCCH 1-0 for feICIC (non-MBSFN ABS) |
Rel-11 |
C78 |
UE supporting E-UTRA TDD and CRS interference handling and ss-CCH interference handling and Feature Group Indicator 115(UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.2.1.7 |
FDD CQI Reporting under AWGN conditions – PUCCH 1-0 for 256QAM in DL |
Rel-12 |
C367 |
UE supporting E-UTRA FDD and 256QAM in DL(UE category 11-12 and UE DL category >=11) |
2Rx, 4Rx |
Note 7 |
|||||||||||
9.2.1.8 |
TDD CQI Reporting under AWGN conditions – PUCCH 1-0 for 256QAM in DL |
Rel-12 |
C368 |
UE supporting E-UTRA TDD and 256QAM in DL(UE category 11-12 and UE DL category >=11) |
2Rx, 4Rx |
Note 7 |
|||||||||||
9.2.2.1 |
FDD CQI Reporting under AWGN conditions – PUCCH 1-1 |
Rel-8 |
C13 b |
UE supporting E-UTRA FDD (UE categories >=2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.2.2.2 |
TDD CQI Reporting under AWGN conditions – PUCCH 1-1 |
Rel-8 to Rel-14 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
|||||||||||
Rel-15 |
C25m |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 Note 7 |
||||||||||||||
9.2.3.1A |
FDD CQI Reporting under AWGN conditions – PUCCH 1-1 for FD-MIMO (With channelMeasRestriction configured) |
Rel-13 |
C337 |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and channeleMeasRestriction-r13 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.2.3.1_D |
FDD CQI Reporting under AWGN conditions – PUCCH 1-1 for eDL-MIMO |
Rel-10 to Rel-14 |
C25a |
UE supporting E-UTRA FDD and Feature Group Indicators 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C25m |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.2.3.2A |
TDD CQI Reporting under AWGN conditions – PUCCH 1-1 for FD-MIMO (With channelMeasRestriction configured) |
Rel-13 |
C338 |
UE supporting E-UTRA TDD and Feature Group Indicator 103 and channeleMeasRestriction-r13 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.2.3.2_D |
TDD CQI Reporting under AWGN conditions – PUCCH 1-1 for eDL-MIMO |
Rel-10 to Rel-14 |
C26a |
UE supporting E-UTRA TDD and Feature Group Indicators 104 and 110 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C26am |
UE supporting E-UTRA TDD and Feature Group Indicators 104 and 110 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD and Feature Group Indicator 110 and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.2.4.1A |
FDD CQI Reporting under AWGN conditions – Single CSI Process With interferenceMeasRestriction configured |
Rel-13 |
C339 |
UE supporting E-UTRA FDD and Maximum CSI processes of One, Three or Four on a component carrier within a band with PDSCH transmission mode 10 and interferenceMeasRestriction-13 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.2.4.1_F |
FDD CQI Reporting under AWGN conditions – Single CSI Process for CoMP |
Rel-11 |
C117 |
UE supporting E-UTRA FDD and Maximum CSI processes of One, Three or Four on a component carrier within a band with PDSCH transmission mode 10 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.2.4.2A |
TDD CQI Reporting under AWGN conditions – Single CSI Process With interferenceMeasRestriction configured |
Rel-13 |
C340 |
UE supporting E-UTRA TDD and Maximum CSI processes of One, Three or Four on a component carrier within a band with PDSCH transmission mode 10 and interferenceMeasRestriction-13 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.2.4.2_F |
TDD CQI Reporting under AWGN conditions – Single CSI Process for CoMP |
Rel-11 |
C118 |
UE supporting E-UTRA TDD and Maximum CSI processes of One, Three or Four on a component carrier within a band with PDSCH transmission mode 10 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.2.5 |
TDD CQI Reporting under AWGN conditions – PUCCH 1-1 (when csi-SubframeSet –r12 and EIMTA-MainConfigServCell-r12 are configured) |
Rel-12 |
C275 |
UE supporting E-UTRA TDD and eIMTA TDD UL-DL reconfiguration and Rel-12 CSI subframe sets (UE Category >= 2) |
|||||||||||||
9.2.6.1 |
LAA CQI Reporting under AWGN Conditions with Frame Structure Type 3 with FDD as Pcell (PUSCH 3-0) |
Rel-13 |
C209 |
UE supporting E-UTRA FDD and downlink LAA with FDD as Pcell |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.2.6.2 |
LAA CQI Reporting under AWGN Conditions with Frame Structure Type 3 with TDD as Pcell (PUSCH 3-0) |
Rel-13 |
C217 |
UE supporting E-UTRA TDD and downlink LAA with TDD as Pcell |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.2.7.1 |
LAA CQI Reporting under AWGN Conditions with Frame Structure Type 3 with FDD as Pcell (PUSCH 3-1) |
Rel-13 |
C218 |
UE supporting E-UTRA FDD and downlink LAA with FDD as Pcell and TM9 on LAA cells |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.2.7.2 |
LAA CQI Reporting under AWGN Conditions with Frame Structure Type 3 with TDD as Pcell (PUSCH 3-1) |
Rel-13 |
C219 |
UE supporting E-UTRA TDD and downlink LAA and TM9 on LAA cells |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.3.1.1.1 |
FDD CQI Reporting under fading conditions – PUSCH 3-0 |
Rel-8 |
C01 |
UE supporting E-UTRA FDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.3.1.1.2 |
TDD CQI Reporting under fading conditions – PUSCH 3-0 |
Rel-8 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.3.1.1.5 |
TDD CQI Reporting under fading conditions – PUCCH 3-0 (when csi-SubframeSet –r12 is configured) |
Rel-12 |
C276 |
UE supporting E-UTRA TDD and Rel-12 CSI subframe sets (UE category >= 1) |
|||||||||||||
9.3.1.2.1_D |
FDD CQI Reporting under fading conditions – PUSCH 3-1 for eDL-MIMO |
Rel-10 to Rel-14 |
C25 |
UE supporting E-UTRA FDD and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
|||||||||||
Rel-15 |
C25m |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 Note 7 |
||||||||||||||
9.3.1.2.2_D |
TDD CQI Reporting under fading conditions – PUSCH 3-1 for eDL-MIMO |
Rel-10 to Rel-14 |
C25a |
UE supporting E-UTRA TDD and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
|||||||||||
Rel-15 |
C25am |
UE supporting E-UTRA TDD and Feature Group Indicator 103 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 Note 7 |
||||||||||||||
9.3.1.2.3 |
FDD CQI Reporting under fading conditions – PUSCH 3-1 for 256QAM in DL |
Rel-12 to Rel-14 |
C260 |
UE supporting E-UTRA FDD and 256QAM in DL(UE category 11-12 and UE DL category >=11) and Feature Group Indicator 103 |
2Rx, 4Rx |
||||||||||||
Rel-15 |
C260m |
UE supporting E-UTRA FDD and 256QAM in DL and Feature Group Indicator 103 and UE DL Category = 13, or UE supporting E-UTRA FDD and 256QAM in DL and (UE category 11-12 and UE DL category 11, 12, 14 or higher) |
Note 6 Note 7 |
||||||||||||||
9.3.1.2.4 |
TDD CQI Reporting under fading conditions – PUSCH 3-1 for 256QAM in DL |
Rel-12 to Rel-14 |
C261 |
UE supporting E-UTRA TDD and 256QAM in DL(UE category 11-12 and UE DL category >=11) and Feature Group Indicator 103 |
2Rx, 4Rx |
||||||||||||
Rel-15 |
C261m |
UE supporting E-UTRA TDD and 256QAM in DL and Feature Group Indicator 103 and UE DL Category = 13, or UE supporting E-UTRA TDD and 256QAM in DL and (UE category 11-12 and UE DL category 11, 12, 14 or higher) |
Note 6 Note 7 |
||||||||||||||
9.3.1.2.6 |
TDD CQI Reporting under fading conditions – PUCCH 3-1 (when csi-SubframeSet –r12 is configured with one CSI process) |
Rel-12 |
C277 |
UE supporting E-UTRA TDD and Rel-12 CSI subframe sets and TM10 ( UE Category >= 1). |
2Rx |
||||||||||||
9.3.1.3.1_E.1 |
FDD CQI Reporting under fading conditions – PUSCH 3-0 for feICIC (non-MBSFN ABS) |
Rel-11 |
C79 |
UE supporting E-UTRA FDD and CRS interference handling and Feature Group Indicator 115 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.3.1.3.2_E.1 |
TDD CQI Reporting under fading conditions – PUSCH 3-0 for feICIC (non-MBSFN ABS) |
Rel-11 |
C80 |
UE supporting E-UTRA TDD and CRS interference handling and ss-CCH interference handling and Feature Group Indicator 115 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.3.2.1.1 |
FDD CQI Reporting under fading conditions – PUCCH 1-0 |
Rel-8 |
C13 b |
UE supporting E-UTRA FDD (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.3.2.1.1_1 |
FDD CQI Reporting under fading conditions – PUCCH 1-0 (Release 9 and forward) |
Rel-9 |
C15 |
UE supporting E-UTRA FDD (UE category 1) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.3.2.1.2 |
TDD CQI Reporting under fading conditions – PUCCH 1-0 |
Rel-8 |
C14 |
UE supporting E-UTRA TDD (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.3.2.1.2_1 |
TDD CQI Reporting under fading conditions – PUCCH 1-0 (Release 9 and forward) |
Rel-9 |
C16 |
UE supporting E-UTRA TDD (UE category 1) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.3.2.2.1_D |
FDD CQI Reporting under fading conditions – PUCCH 1-1 for eDL-MIMO |
Rel-10 to Rel-14 |
C25x |
UE supporting E-UTRA FDD and Feature Group Indicator 103 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
Rel-15 |
C25xm |
UTRA FDD and Feature Group Indicator 103 and ((2 <= UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.3.2.2.2_D |
TDD CQI Reporting under fading conditions – PUCCH 1-1 for eDL-MIMO |
Rel-10 to Rel-14 |
C28y |
UE supporting E-UTRA TDD and Feature Group Indicators 104 and 110 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
Rel-15 |
C28ym |
UE supporting E-UTRA TDD and Feature Group Indicators 104 and 110 and ((2 <= UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD and Feature Group Indicator 110 and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.3.3.1.1 |
FDD CQI Reporting under fading conditions and frequency-selective interference – PUSCH 3-0 |
Rel-8 |
C01 |
UE supporting E-UTRA FDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.3.3.1.2 |
TDD CQI Reporting under fading conditions and frequency-selective interference – PUSCH 3-0 |
Rel-8 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.3.4.1.1 |
FDD CQI Reporting under fading conditions – PUSCH 2-0 |
Rel-9 |
C32 |
UE supporting E-UTRA FDD and Feature Group Indicator 1 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.3.4.1.2 |
TDD CQI Reporting under fading conditions – PUSCH 2-0 |
Rel-9 |
C37 |
UE supporting E-UTRA TDD and Feature Group Indicator 1 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.3.4.2.1 |
FDD CQI Reporting under fading conditions – PUCCH 2-0 |
Rel-9 |
C36 |
UE supporting E-UTRA FDD and Feature Group Indicator 2 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.3.4.2.2 |
TDD CQI Reporting under fading conditions – PUCCH 2-0 |
Rel-9 |
C38 |
UE supporting E-UTRA TDD and Feature Group Indicator 2 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.3.5.1.1 |
FDD CQI Reporting under fading conditions – PUCCH 1-0 – Enhanced Performance Requirement Type A |
Rel-11 |
C44 |
UE supporting E-UTRA FDD and the enhanced performance requirements type A for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.3.5.1.2 |
TDD CQI Reporting under fading conditions – PUCCH 1-0 – Enhanced Performance Requirement Type A |
Rel-11 |
C45 |
UE supporting E-UTRA TDD and the enhanced performance requirements type A for LTE |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.3.5.2.1 |
FDD CQI Reporting under fading conditions – PUCCH 1-1 – Enhanced Performance Requirement Type A |
Rel-11 |
C44z |
UE supporting E-UTRA FDD and the enhanced performance requirements type A for LTE (UE Category >= 2) and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.3.5.2.2 |
TDD CQI Reporting under fading conditions – PUCCH 1-1 – Enhanced Performance Requirement Type A |
Rel-11 |
C45i |
UE supporting E-UTRA TDD and the enhanced performance requirements type A for LTE (UE Category >= 2) and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.3.6.1_F.1 |
FDD CQI Reporting under fading conditions with Single CSI process for CoMP |
Rel-11 |
C50a |
UE supporting E-UTRA FDD and Maximum CSI processes of One on a component carrier within a band with PDSCH transmission mode 10 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.3.6.1_F.2 |
FDD CQI Reporting under fading conditions with Three CSI processes for CoMP |
Rel-11 |
C96 |
UE supporting E-UTRA FDD and Maximum CSI processes of Three on a component carrier within a band with PDSCH transmission mode 10 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.3.6.1_F.3 |
FDD CQI Reporting under fading conditions with Four CSI processes for CoMP |
Rel-11 |
C97 |
UE supporting E-UTRA FDD and Maximum CSI processes of Four on a component carrier within a band with PDSCH transmission mode 10 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.3.6.2_F.1 |
TDD CQI Reporting under fading conditions with Single CSI process for CoMP |
Rel-11 |
C51a |
UE supporting E-UTRA TDD and Maximum CSI processes of One on a component carrier within a band with PDSCH transmission mode 10 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.3.6.2_F.2 |
TDD CQI Reporting under fading conditions with Three CSI processes for CoMP |
Rel-11 |
C98 |
UE supporting E-UTRA TDD and Maximum CSI processes of Three on a component carrier within a band with PDSCH transmission mode 10 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.3.6.2_F.3 |
TDD CQI Reporting under fading conditions with Four CSI processes for CoMP |
Rel-11 |
C99 |
UE supporting E-UTRA TDD and Maximum CSI processes of Four on a component carrier within a band with PDSCH transmission mode 10 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.3.7.1 |
FDD CQI Reporting under fading conditions – PUSCH 3-2 for eDL MIMO Enhancement |
Rel-12 to Rel-14 |
C25b |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and PUSCH feedback mode 3-2 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
9.3.7.1 Note 7 |
||||||||||
Rel-15 |
C25bm |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and PUSCH feedback mode 3-2 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and PUSCH feedback mode 3-2 and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.3.7.2 |
TDD CQI Reporting under fading conditions – PUSCH 3-2 for eDL MIMO Enhancement |
Rel-12 to Rel-14 |
C25c |
UE supporting E-UTRA TDD and Feature Group Indicator 103 and PUSCH feedback mode 3-2 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
Rel-15 |
C25cm |
UE supporting E-UTRA TDD and Feature Group Indicator 103 and PUSCH feedback mode 3-2 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD and PUSCH feedback mode 3-2 and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.3.8.1.1 |
FDD CQI Reporting under fading conditions – PUCCH 1-1 (Cell-Specific Reference Symbols) TM4 – Enhanced Receiver Type B |
Rel-12 |
C152 |
UE supporting E-UTRA FDD and the enhanced performance requirements type B for LTE (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.3.8.1.2 |
TDD CQI Reporting under fading conditions – PUCCH 1-1 (Cell-Specific Reference Symbols) TM4 – Enhanced Receiver Type B |
Rel-12 |
C153 |
UE supporting E-UTRA TDD and the enhanced performance requirements type B for LTE (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.3.8.2.1 |
FDD CQI Reporting under fading conditions – PUCCH 1-1 (CSI Reference Symbol) TM9 – Enhanced Receiver Type B |
Rel-12 |
C152 |
UE supporting E-UTRA FDD and the enhanced performance requirements type B for LTE (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.3.8.2.2 |
TDD CQI Reporting under fading conditions – PUCCH 1-1 (CSI Reference Symbol) TM9 – Enhanced Receiver Type B |
Rel-12 |
C153 |
UE supporting E-UTRA TDD and the enhanced performance requirements type B for LTE (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.3.8.3.1 |
FDD CQI Reporting under fading conditions – PUCCH 1-1 (CSI Reference Symbol) TM10 with TM9 interference – Enhanced Receiver Type B |
Rel-12 |
C152 |
UE supporting E-UTRA FDD and the enhanced performance requirements type B for LTE (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.3.8.3.2 |
TDD CQI Reporting under fading conditions – PUCCH 1-1 (CSI Reference Symbol) TM10 with TM9 interference – Enhanced Receiver Type B |
Rel-12 |
C153 |
UE supporting E-UTRA TDD and the enhanced performance requirements type B for LTE (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.4.1.1.1 |
FDD PMI Reporting – PUSCH 3-1 (Single PMI) |
Rel-8 |
C01 |
UE supporting E-UTRA FDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.4.1.1.2 |
TDD PMI Reporting – PUSCH 3-1 (Single PMI) |
Rel-8 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.4.1.2.1 |
FDD PMI Reporting – PUCCH 2-1 (Single PMI) |
Rel-9 |
C36 |
UE supporting E-UTRA FDD and Feature Group Indicator 2 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.4.1.2.2 |
TDD PMI Reporting – PUCCH 2-1 (Single PMI) |
Rel-9 |
C38 |
UE supporting E-UTRA TDD and Feature Group Indicator 2 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.4.1.3.1_D |
FDD PMI Reporting – PUSCH 3-1 (Single PMI) for eDL-MIMO |
Rel-10 to Rel-14 |
C25 |
UE supporting E-UTRA FDD and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
Rel-15 |
C25m |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.4.1.3.2_D |
TDD PMI Reporting – PUSCH 3-1 (Single PMI) for eDL-MIMO |
Rel-10 to Rel-14 |
C26 |
UE supporting E-UTRA TDD and Feature Group Indicator 104 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
Rel-15 |
C26m |
UE supporting E-UTRA TDD and Feature Group Indicator 104 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.4.1.3.3 |
FDD PMI Reporting with 12Tx Class A codebook – PUSCH 3-1 (Single PMI) for FD-MIMO |
Rel-13 |
C13b |
UE supporting E-UTRA FDD (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.4.1.3.4 |
TDD PMI Reporting with 12Tx Class A codebook – PUSCH 3-1 (Single PMI) for FD-MIMO |
Rel-13 |
C14b |
UE supporting E-UTRA TDD (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.4.1.4.1 |
FDD PMI Reporting with 4Tx enhanced codebook – PUCCH 1-1 (Single PMI) for eDL MIMO Enhancement |
Rel-12 to Rel-14 |
C25d |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and enhanced 4Tx codebook |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
Rel-15 |
C25m |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.4.1.4.2 |
TDD PMI Reporting with 4Tx enhanced codebook – PUCCH 1-1 (Single PMI) for eDL MIMO Enhancement |
Rel-12 to Rel-14 |
C25e |
UE supporting E-UTRA TDD and Feature Group Indicator 103 and enhanced 4Tx codebook |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
Rel-15 |
C25em |
UE supporting E-UTRA TDD and Feature Group Indicator 103 and enhanced 4Tx codebook and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD and enhanced 4Tx codebook and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.4.1.4.3 |
FDD PMI Reporting with Class B alternative codebook – PUCCH 1-1 for FD-MIMO |
Rel-13 |
C13b |
UE supporting E-UTRA FDD (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.4.1.4.4 |
TDD PMI Reporting with Class B alternative codebook – PUCCH 1-1 for FD-MIMO |
Rel-13 |
C14b |
UE supporting E-UTRA TDD (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.4.2.1.1 |
FDD PMI Reporting – PUSCH 1-2 (Multiple PMI) |
Rel-8 only |
C11 |
UE supporting E-UTRA FDD and operating bands supporting 20 MHz Bandwidth (UE categories 2, 3, 4, 5) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.4.2.1.1_1 |
FDD PMI Reporting – PUSCH 1-2 (Multiple PMI) (Release 9 and forward) |
Rel-9 |
C01 |
UE supporting E-UTRA FDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.4.2.1.2 |
TDD PMI Reporting – PUSCH 1-2 (Multiple PMI) |
Rel-8 only |
C12 |
UE supporting E-UTRA TDD and operating bands supporting 20 MHz Bandwidth (UE categories 2, 3, 4, 5) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.4.2.1.2_1 |
TDD PMI Reporting – PUSCH 1-2 (Multiple PMI) (Release 9 and forward) |
Rel-9 |
C02 |
UE supporting E-UTRA TDD |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.4.2.2.1 |
FDD PMI Reporting – PUSCH 2-2 (Multiple PMI) |
Rel-9 |
C32 |
UE supporting E-UTRA FDD and Feature Group Indicators 1 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.4.2.2.2 |
TDD PMI Reporting – PUSCH 2-2 (Multiple PMI) |
Rel-9 |
C33 |
UE supporting E-UTRA TDD and Feature Group Indicators 1 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.4.2.3.1_D |
FDD PMI Reporting – PUSCH 1-2 (Multiple PMI) for eDL-MIMO |
Rel-10 to Rel-14 |
C25 |
UE supporting E-UTRA FDD and Feature Group Indicator 103 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
Rel-15 |
C25m |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.4.2.3.2_D |
TDD PMI Reporting – PUSCH 1-2 (Multiple PMI) for eDL-MIMO |
Rel-10 to Rel-14 |
C26 |
UE supporting E-UTRA TDD and Feature Group Indicator 104 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C26m |
UE supporting E-UTRA TDD and Feature Group Indicator 104 and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.4.2.3.3 |
FDD PMI Reporting with 4Tx enhanced codebook – PUSCH 1-2 (Multiple PMI) for eDL-MIMO Enhancement |
Rel-12 to Rel-14 |
C25d |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and enhanced 4Tx codebook |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
Rel-15 |
C25dm |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and enhanced 4Tx codebook and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and enhanced 4Tx codebook and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.4.2.3.4 |
TDD PMI Reporting with 4Tx enhanced codebook – PUSCH 1-2 (Multiple PMI) for eDL-MIMO Enhancement |
Rel-12 to Rel-14 |
C25e |
UE supporting E-UTRA TDD and eDL-MIMO Enhancement and Feature Group Indicator 103 and enhanced 4Tx codebook |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
|||||||||||
Rel-15 |
C25em |
UE supporting E-UTRA TDD and Feature Group Indicator 103 and enhanced 4Tx codebook and ((UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD and enhanced 4Tx codebook and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.4.2.3.5 |
FDD PMI Reporting with Class A 16Tx codebook – PUSCH 1-2 (Multiple PMI) for FD-MIMO |
Rel-13 |
C13b |
UE supporting E-UTRA FDD (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.4.2.3.6 |
TDD PMI Reporting with Class A 16Tx codebook – PUSCH 1-2 (Multiple PMI) for FD-MIMO |
Rel-13 |
C14b |
UE supporting E-UTRA TDD (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.5.1.1 |
FDD RI Reporting – PUCCH 1-1 |
Rel-8 and Rel-9 only |
C13a |
UE supporting E-UTRA FDD (UE Category 2-5) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.5.1.1_1 |
FDD RI Reporting – PUCCH 1-1 (Release 10) |
Rel-10 only |
C13 |
UE supporting E-UTRA FDD (UE Category 2-8) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.5.1.1_2 |
FDD RI Reporting- PUCCH 1-1 (Release 11) |
Rel-11 |
C13b |
UE supporting E-UTRA FDD (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.5.1.2 |
TDD RI Reporting – PUSCH 3-1 |
Rel-8 and Rel-9 only |
C14a |
UE supporting E-UTRA TDD (UE Category 2-5) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.5.1.2_1 |
TDD RI Reporting – PUSCH 3-1 (Release 10) |
Rel-10 only |
C14 |
UE supporting E-UTRA TDD (UE Category 2-8) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.5.1.2_2 |
TDD RI Reporting- PUSCH 3-1 (Release 11) |
Rel-11 |
C14b |
UE supporting E-UTRA TDD (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.5.2.1_D |
FDD RI Reporting – PUCCH 1-1 for eDL-MIMO |
Rel-10 to Rel-14 |
C25x |
UE supporting E-UTRA FDD and Feature Group Indicators 103 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C25xm |
UE supporting E-UTRA FDD and Feature Group Indicator 103 and ((2 <= UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.5.2.2_D |
TDD RI Reporting – PUCCH 1-1 for eDL-MIMO |
Rel-10 to Rel-14 |
C25y |
UE supporting E-UTRA TDD and Feature Group Indicator 103 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C25ym |
UE supporting E-UTRA TDD and Feature Group Indicator 103 and ((2 <= UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.5.3.1_C.1 |
FDD RI Reporting – PUCCH 1-0 for eICIC (non-MBSFN ABS) |
Rel-10 |
C29 |
UE supporting E-UTRA FDD and Feature Group Indicator 115 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.5.3.2_C.1 |
TDD RI Reporting – PUCCH 1-0 for eICIC (non-MBSFN ABS) |
Rel-10 |
C30 |
UE supporting E-UTRA TDD and Feature Group Indicator 115 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.5.4.1_E.1 |
FDD RI Reporting – PUCCH 1-0 for feICIC (non-MBSFN ABS) |
Rel-11 |
C77 |
UE supporting E-UTRA FDD and CRS interference handling and Feature Group Indicator 115 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.5.4.2_E.1 |
TDD RI Reporting – PUCCH 1-0 for feICIC (non-MBSFN ABS) |
Rel-11 |
C78 |
UE supporting E-UTRA TDD and CRS interference handling and ss-CCH interference handling and Feature Group Indicator 115(UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.5.5.1_F.1 |
FDD RI Reporting with Single CSI processes for CoMP |
Rel-11 |
C50 |
UE supporting E-UTRA FDD and Maximum CSI processes of One on a component carrier within a band with PDSCH transmission mode 10 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.5.5.1_F.2 |
FDD RI Reporting with Multiple CSI processes for CoMP |
Rel-11 |
C52 |
UE supporting E-UTRA FDD and Maximum CSI processes of Three or Four on a component carrier within a band with PDSCH transmission mode 10 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.5.5.2_F.1 |
TDD RI Reporting with Single CSI process for CoMP |
Rel-11 |
C51 |
UE supporting E-UTRA TDD and Maximum CSI processes of One on a component carrier within a band with PDSCH transmission mode 10 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.5.5.2_F.2 |
TDD RI Reporting with Multiple CSI processes for CoMP |
Rel-11 |
C53 |
UE supporting E-UTRA TDD and Maximum CSI processes of Three or Four on a component carrier within a band with PDSCH transmission mode 10 (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.6.1.1_A.1 |
FDD CQI Reporting under AWGN conditions – PUCCH 1-0 for CA (2 DL CA) |
Rel-10 |
C108 |
UE supporting E-UTRA FDD and intra-band contiguous DL CA or inter-band DL CA (UE Category >= 3) |
Refer to 36.521-1 9.1.1.2 |
2Rx, 4Rx |
Test execution not necessary if 9.6.1.1_A.2 is executed. Note 7 |
||||||||||
Rel-11 |
C103 |
UE supporting E-UTRA FDD and intra-band non-contiguous DL CA(UE Category >= 3) |
|||||||||||||||
9.6.1.1_A.2 |
FDD CQI Reporting under AWGN conditions – PUCCH 1-0 for CA (3 DL CA) |
Rel-10 |
C124 |
UE supporting E-UTRA FDD and 3DL with intra-band contiguous CA, or 3DL with inter-band CA, or 3DL with intra-band contiguous and inter-band CA (UE Category >= 5) |
Refer to 36.521-1 9.1.1.2 |
2Rx, 4Rx |
Test execution not necessary if 9.6.1.1_A.3 is executed. Note 7 |
||||||||||
Rel-11 |
C125 |
UE supporting E-UTRA FDD and 3DL with intra-band non-contiguous and inter-band CA, or 3DL with intra-band non-contiguous and intra-band contiguous CA (UE Category >= 5) |
TBD |
2Rx, 4Rx |
Test execution not necessary if 9.6.1.1_A.3 is executed. Note 7 |
||||||||||||
9.6.1.1_A.3 |
FDD CQI Reporting under AWGN conditions – PUCCH 1-0 for CA (4DL CA) |
Rel-11 |
C192 |
UE supporting E-UTRA FDD and 4DL with intra-band contiguous CA, or 4DL with inter-band CA, or 4DL with intra-band contiguous and inter-band CA (UE Category >= 8) |
2Rx, 4Rx |
Test execution not necessary if 9.6.1.1_A.4 is executed. Note 7 |
|||||||||||
Rel-11 |
C193 |
UE supporting E-UTRA FDD and 4DL with intra-band non-contiguous and inter-band CA, or 4DL with intra-band non-contiguous and intra-band contiguous CA (UE Category >= 8) |
Test execution not necessary if 9.6.1.1_A.4 is executed. |
||||||||||||||
9.6.1.1_A.4 |
FDD CQI Reporting under AWGN conditions – PUCCH 1-0 for CA (5DL CA) |
Rel-11 |
C192a |
UE supporting E-UTRA FDD and 5DL with Intra-band contiguous and Inter-band CA or 5DL with Intra-band non-contiguous and Inter-band CA or 5DL with Intra-band non-contiguous and Intra-band contiguous CA (UE Category 8 and >= 11) |
2Rx, 4Rx |
Note 7 |
|||||||||||
Rel-12 |
C193a |
UE supporting E-UTRA FDD and 5DL Inter-band CA (UE Category 8 and>= 11) |
|||||||||||||||
9.6.1.1_A.5 |
FDD CQI Reporting under AWGN conditions – PUCCH 1-0 for CA (6DL CA) |
Rel-14 |
C363 |
UE supporting E-UTRA FDD and 6DL with Intra-band contiguous and Inter-band CA or 6DL with Intra-band non-contiguous and Inter-band CA or 6DL with Inter-band CA (UE Category 8 and >= 11) |
2Rx, 4Rx |
Note 7 |
|||||||||||
9.6.1.1_A.6 |
FDD CQI Reporting under AWGN conditions – PUCCH 1-0 for CA (7DL CA) |
Rel-14 |
C364 |
UE supporting E-UTRA FDD and 7DL with Intra-band contiguous and Inter-band CA or 7DL with Intra-band non-contiguous and Inter-band CA (UE Category 8 and >= 11) |
2Rx, 4Rx |
Note 7 |
|||||||||||
9.6.1.2_A.1 |
TDD CQI Reporting under AWGN conditions – PUCCH 1-0 for CA (2DL CA) |
Rel-10 |
C114 |
UE supporting E-UTRA TDD and intra-band contiguous DL CA (UE Category >= 3) |
Refer to 36.521-1 9.1.1.2 |
2Rx, 4Rx |
Test execution not necessary if 9.6.1.2_A.2 is executed. Note 7 |
||||||||||
9.6.1.2_A .2 |
TDD CQI Reporting under AWGN conditions – PUCCH 1-0 for CA (3 DL CA) |
Rel-10 |
C128 |
UE supporting E-UTRA TDD and 3DL with intra-band contiguous CA, or 3DL with inter-band CA, or 3DL with intra-band contiguous and inter-band CA (UE Category >= 5) |
Refer to 36.521-1 9.1.1.2 |
2Rx, 4Rx |
Test execution not necessary if 9.6.1.2_A.3 is executed. Note 7 |
||||||||||
Rel-11 |
C129 |
UE supporting E-UTRA TDD and 3DL with intra-band non-contiguous and inter-band CA, or 3DL with intra-band non-contiguous and intra-band contiguous CA (UE Category >= 5) |
Test execution not necessary if 9.6.1.2_A.3 is executed. |
||||||||||||||
9.6.1.2_A.3 |
TDD CQI Reporting under AWGN conditions – PUCCH 1-0 for CA (4 DL CA) |
Rel-11 |
C270 |
UE supporting E-UTRA TDD and 4DL with intra-band contiguous CA, or 4DL with inter-band CA, or 4DL with intra-band contiguous and inter-band CA (UE Category >= 8) |
Test execution not necessary if 9.6.1.2_A.4 is executed. |
||||||||||||
Rel-11 |
C271 |
UE supporting E-UTRA TDD and 4DL with intra-band non-contiguous and inter-band CA, or 4DL with intra-band non-contiguous and intra-band contiguous CA (UE Category >= 8) |
Test execution not necessary if 9.6.1.2_A.4 is executed. |
||||||||||||||
9.6.1.2_A.4 |
TDD CQI Reporting under AWGN conditions – PUCCH 1-0 for CA (5 DL CA) |
Rel-11 |
C272 |
UE supporting E-UTRA TDD and 5DL with intra-band contiguous CA, or 5DL with inter-band CA, or 5DL with intra-band contiguous and inter-band CA (UE Category 8 and >=11) |
|||||||||||||
Rel-11 |
C273 |
UE supporting E-UTRA TDD and 5DL with intra-band non-contiguous and inter-band CA, or 5DL with intra-band non-contiguous and intra-band contiguous CA (UE Category 8 and >=11) |
|||||||||||||||
9.6.1.2_A.5 |
TDD CQI Reporting under AWGN conditions – PUCCH 1-0 for CA (6 DL CA) |
Rel-14 |
C365 |
UE supporting E-UTRA TDD and 6DL with Intra-band contiguous and Inter-band CA or 6DL with Intra-band non-contiguous and Inter-band CA or 6DL with Inter-band CA (UE Category 8 and >= 11) |
2Rx, 4Rx |
Note 7 |
|||||||||||
9.6.1.2_A.6 |
TDD CQI Reporting under AWGN conditions – PUCCH 1-0 for CA (7 DL CA) |
Rel-14 |
C366 |
UE supporting E-UTRA TDD and 7DL with Intra-band contiguous and Inter-band CA or 7DL with Intra-band non-contiguous and Inter-band CA (UE Category 8 and >= 11) |
2Rx, 4Rx |
Note 7 |
|||||||||||
9.6.1.3.1 |
TDD FDD CA CQI Reporting under AWGN conditions – PUCCH 1-0 for FDD PCell (2DL CA) |
Rel-12 |
C132 |
UE supporting E-UTRA FDD and TDD and 2DL CA with FDD as PCell (UE Category >= 3) |
TBD |
2Rx, 4Rx |
Test execution not necessary if 9.6.1.3.2 is executed. Note 7 |
||||||||||
9.6.1.3.2 |
TDD FDD CA CQI Reporting under AWGN conditions – PUCCH 1-0 for FDD PCell (3DL CA) |
Rel-12 |
C133 |
UE supporting E-UTRA FDD and TDD and 3DL CA with FDD as PCell (UE Category >= 5) |
TBD |
2Rx, 4Rx |
Test execution not necessary if 9.6.1.3.3 is executed. Note 7 |
||||||||||
9.6.1.3.3 |
TDD FDD CA CQI Reporting under AWGN conditions – PUCCH 1-0 for FDD PCell (4DL CA) |
Rel-12 |
C133a |
UE supporting E-UTRA FDD and TDD and 4DL CA with FDD as PCell (UE Category >= 8) |
TBD |
2Rx, 4Rx |
Test execution not necessary if 9.6.1.3.4 is executed. Note 7 |
||||||||||
9.6.1.3.4 |
TDD FDD CQI Reporting under AWGN conditions – PUCCH 1-0 for FDD PCell (5DL CA) |
Rel-12 |
C133b |
UE supporting E-UTRA FDD and TDD and 5DL CA with FDD as PCell (UE Category 8, and Category 11 and onwards) |
TBD |
2Rx, 4Rx |
Note 7 |
||||||||||
9.6.1.4.1 |
TDD FDD CA CQI Reporting under AWGN conditions – PUCCH 1-0 for TDD PCell (2DL CA) |
Rel-12 |
C134 |
UE supporting E-UTRA FDD and TDD and 2DL CA with TDD as PCell (UE Category >= 3) |
TBD |
2Rx, 4Rx |
Test execution not necessary if 9.6.1.4.2 is executed. Note 7 |
||||||||||
9.6.1.4.2 |
TDD FDD CA CQI Reporting under AWGN conditions – PUCCH 1-0 for TDD PCell (3DL CA) |
Rel-12 |
C135 |
UE supporting E-UTRA FDD and TDD and 3DL CA with TDD as PCell (UE Category >= 5) |
TBD |
2Rx, 4Rx |
Test execution not necessary if 9.6.1.4.3 is executed. Note 7 |
||||||||||
9.6.1.4.3 |
TDD FDD CA CQI Reporting under AWGN conditions – PUCCH 1-0 for TDD PCell (4DL CA) |
Rel-12 |
C135a |
UE supporting E-UTRA FDD and TDD and 4DL CA with TDD as PCell (UE Category >= 8) |
TBD |
2Rx, 4Rx |
Test execution not necessary if 9.6.1.4.4 is executed. Note 7 |
||||||||||
9.6.1.4.4 |
TDD FDD CQI Reporting under AWGN conditions – PUCCH 1-0 for TDD PCell (5DL CA) |
Rel-12 |
C133b |
UE supporting E-UTRA FDD and TDD and 5DL CA with FDD as PCell (UE Category 8, and Category 11 and onwards) |
TBD |
2Rx, 4Rx |
Note 7 |
||||||||||
9.7.1.1 |
FDD and Half duplex FDD CQI reporting definition under AWGN conditions for UE category 0 |
Rel-12 |
C145 |
UE supporting E-UTRA FDD (UE category 0) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.7_1.1.1 |
FDD CQI reporting under AWGN conditions – PUCCH 1-0 for UE category 1bis |
Rel-13 |
C145d |
UE supporting E-UTRA FDD (UE category 1bis) |
Each "Test Number" to be performed once, in a chosen band supporting |
||||||||||||
9.7_1.1.2 |
TDD CQI reporting under AWGN conditions – PUCCH 1-0 for UE category 1bis |
Rel-13 |
C156f |
UE supporting E-UTRA TDD (UE category 1bis) |
Each "Test Number" to be performed once, in a chosen band supporting |
||||||||||||
9.7_1.1.3 |
FDD CQI reporting under fading conditions – PUSCH 3-0 for UE category 1bis |
Rel-13 |
C145d |
UE supporting E-UTRA FDD (UE category 1bis) |
Each "Test Number" to be performed once, in a chosen band supporting |
||||||||||||
9.7_1.1.4 |
TDD CQI reporting under fading conditions – PUSCH 3-0 for UE category 1bis |
Rel-13 |
C156f |
UE supporting E-UTRA TDD (UE category 1bis) |
Each "Test Number" to be performed once, in a chosen band supporting |
||||||||||||
9.7.1.2 |
TDD CQI reporting definition under AWGN conditions for UE category 0 |
Rel-12 |
C119 |
UE supporting E-UTRA TDD (UE category 0) |
|||||||||||||
9.7.2.1 |
FDD and Half duplex FDD CQI reporting definition under fading conditions for UE category 0 |
Rel-12 |
C145 |
UE supporting E-UTRA FDD (UE category 0) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.7.2.2 |
TDD CQI reporting definition under fading conditions for UE category 0 |
Rel-12 |
C156 |
UE supporting E-UTRA TDD (UE category 0) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.8.1.1 |
FDD and Half duplex FDD CQI reporting definition under AWGN conditions for UE supporting coverage enhancement |
Rel-13 |
C145k |
UE supporting E-UTRA FDD or HD-FDD and CEModeA |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.8.1.2 |
TDD CQI reporting definition under AWGN conditions for UE supporting coverage enhancement |
Rel-13 |
C156a |
UE supporting E-UTRA TDD and UE category M1 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.8.2.1 |
FDD and Half-duplex FDD UE-selected subband CQI for UE supporting coverage enhancement |
Rel-13 |
C145a |
UE supporting E-UTRA FDD and UE category M1 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.8.2.2 |
TDD UE-selected subband CQI for UE supporting coverage enhancement |
Rel-13 |
C156a |
UE supporting E-UTRA TDD and UE category M1 |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.8.3.1 |
FDD and half duplex FDD CQI reporting under AWGN conditions for UE supporting coverage enhancement and 64QAM |
Rel-15 |
C145i |
UE supporting E-UTRA FDD and CEModeA and 64QAM |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.8.3.2 |
TDD CQI reporting under AWGN conditions for UE supporting coverage enhancement and 64QAM |
Rel-15 |
C156k |
UE supporting E-UTRA TDD and CEModeA and 64QAM |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.8.4.1 |
FDD and half duplex FDD CQI reporting under AWGN conditions for UE supporting coverage enhancement alternative table |
Rel-15 |
C145j |
UE supporting E-UTRA FDD and CEModeA and alternative table |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.8.4.2 |
TDD CQI reporting under AWGN conditions for UE supporting coverage enhancement alternative table |
Rel-15 |
C156l |
UE supporting E-UTRA TDD and CEModeA and alternative table |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.9.1.1.1 |
FDD CQI Reporting under AWGN conditions – PUCCH 1-0 with Rank 1 1×4 |
Rel-10 |
C113b |
UE supporting E-UTRA FDD with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.9.1.1.2 |
TDD CQI Reporting under AWGN conditions – PUCCH 1-0 with Rank 1 1×4 |
Rel-10 |
C177 |
UE supporting E-UTRA TDD with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.9.1.2.1 |
FDD CQI Reporting under AWGN conditions – PUCCH 1-1 with rank 2 4×4 |
Rel-10 to Rel-14 |
C178 |
UE supporting E-UTRA FDD and eDL-MIMO and Feature Group Indicator 103 with 4Rx antenna ports (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C178m |
UE supporting E-UTRA FDD and eDL-MIMO and Feature Group Indicator 103 with 4Rx antenna ports and ((2 <= UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD with 4Rx antenna ports and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.9.1.2.2 |
TDD CQI Reporting under AWGN conditions – PUCCH 1-1 with rank 2 8×4 |
Rel-10 to Rel-14 |
C179 |
UE supporting E-UTRA TDD and eDL-MIMO and Feature Group Indicator 104 with 4Rx antenna ports (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C179m |
UE supporting E-UTRA TDD and eDL-MIMO and Feature Group Indicator 104 with 4Rx antenna ports and ((2 <= UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD with 4Rx antenna ports and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.9.1.3.1 |
FDD CQI Reporting under AWGN conditions – PUCCH 1-1 with rank 4 4×4 |
Rel-10 |
C180 |
UE supporting E-UTRA FDD with 4Rx antenna ports and 4-layer spatial multiplexing (UE Category >= 5) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.9.1.3.2 |
TDD CQI Reporting under AWGN conditions – PUCCH 1-1 with rank 4 4×4 |
Rel-10 |
C181 |
UE supporting E-UTRA TDD with 4Rx antenna ports and 4-layer spatial multiplexing (UE Category >= 5) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
9.9.1.4.1 |
FDD CQI Reporting under AWGN conditions – PUCCH 1-1 with rank 3 4×4 |
Rel-10 to Rel-14 |
C182 |
UE supporting E-UTRA FDD and eDL-MIMO and Feature Group Indicator 103 with 4Rx antenna ports (UE Category >= 5) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C182m |
UE supporting E-UTRA FDD and eDL-MIMO and Feature Group Indicator 103 with 4Rx antenna ports and ((5 <= UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD with 4Rx antenna ports and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.9.1.4.2 |
TDD CQI Reporting under AWGN conditions – PUCCH 1-1 with rank 3 4×4 |
Rel-10 to Rel-14 |
C183 |
UE supporting E-UTRA TDD andUE Category ≥ 5 and Feature Group Indicator 103 with 4Rx antenna ports |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C183m |
UE supporting E-UTRA TDD and Feature Group Indicator 103 with 4Rx antenna ports and ((5 <= UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD with 4Rx antenna ports and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.9.2.1.1 |
FDD CQI Reporting under fading conditions – PUCCH 1-0 – Enhanced Performance Requirement Type A 1×4 |
Rel-11 |
C197 |
UE supporting E-UTRA FDD with 4Rx antenna ports and the enhanced performance requirements type A for LTE |
Each" Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
9.9.2.1.2 |
TDD CQI Reporting under fading conditions – PUCCH 1-0 – Enhanced Performance Requirement Type A 1×4 |
Rel-11 |
C198 |
UE supporting E-UTRA TDD with 4Rx antenna ports and the enhanced performance requirements type A for LTE |
Each" Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
9.9.2.2.1 |
FDD CQI Reporting under fading conditions – PUCCH 1-1 – Enhanced Performance Requirement Type A2 x4 |
Rel-11 to Rel-14 |
C199 |
UE supporting E-UTRA FDD with 4Rx antenna ports and the enhanced performance requirements type A for LTE (UE Category >= 2) and Feature Group Indicator 103 |
Each" Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
Rel-15 |
C199m |
UE supporting E-UTRA FDD with 4Rx antenna ports and the enhanced performance requirements type A for LTE and Feature Group Indicator 103 and ((2 <= UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD with 4Rx antenna ports and the enhanced performance requirements type A for LTE and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.9.2.2.2 |
TDD CQI Reporting under fading conditions – PUCCH 1-1 – Enhanced Performance Requirement Type A2 x4 |
Rel-11 to Rel-14 |
C200 |
UE supporting E-UTRA TDD with 4Rx antenna ports and the enhanced performance requirements type A for LTE (UE Category >= 2) and Feature Group Indicator 103 |
Each" Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
Rel-15 |
C200m |
UE supporting E-UTRA TDD with 4Rx antenna ports and the enhanced performance requirements type A for LTE and Feature Group Indicator 103 and ((2 <= UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD with 4Rx antenna ports and the enhanced performance requirements type A for LTE and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.9.3.1.1 |
TDD PMI Reporting – PUSCH 3-1 (Single PMI) 8×4 |
Rel-10 to Rel-14 |
C179 |
UE supporting E-UTRA TDD and eDL-MIMO and Feature Group Indicator 104 with 4Rx antenna ports (UE Category >= 2) |
Each" Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
Rel-15 |
C179m |
UE supporting E-UTRA TDD and eDL-MIMO and Feature Group Indicator 104 with 4Rx antenna ports and ((2 <= UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD with 4Rx antenna ports and (UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.9.4.1.1 |
FDD RI Reporting- PUCCH 1-1 4×4 |
Rel-10 |
C203 |
UE supporting E-UTRA FDD with 4Rx antenna ports (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
9.9.4.1.2 |
TDD RI Reporting- PUSCH 3-1 4×4 |
Rel-10 |
C204 |
UE supporting E-UTRA TDD with 4Rx antenna ports (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
9.9.4.2.1 |
FDD RI Reporting- PUCCH 1-1 for eDL-MIMO 4×4 |
Rel-10 to Rel-14 |
C205 |
UE supporting E-UTRA FDD and eDL-MIMO and Feature Group Indicator 103 with 4Rx antenna ports (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
Rel-15 |
C205m |
UE supporting E-UTRA FDD and eDL-MIMO and Feature Group Indicator 103 with 4Rx antenna ports and ((2 <= UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA FDD with 4Rx antenna ports and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.9.4.2.2 |
TDD RI Reporting- PUCCH 1-1 for eDL-MIMO 4×4 |
Rel-10 to Rel-14 |
C206 |
UE supporting E-UTRA TDD and eDL-MIMO and Feature Group Indicator 103 with 4Rx antenna ports (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW and 4Rx antenna ports |
||||||||||||
Rel-15 |
C206m |
UE supporting E-UTRA TDD and eDL-MIMO and Feature Group Indicator 103 with 4Rx antenna ports and ((2 <= UE Category < 8 or 8 < UE Category < 11) and (UE DL Category < 11 or UE DL Category = 13 )), or UE supporting E-UTRA TDD with 4Rx antenna ports and (UE Category = 8 or UE Category >= 11 or UE DL Category = 11 or UE DL Category = 12 or UE DL Category >=14) |
Note 6 |
||||||||||||||
9.10.1.1 |
FDD CSI-RS Resource Indicator Reporting – PUSCH 3-1 |
Rel-13 |
C13b |
UE supporting E-UTRA FDD (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.10.1.2 |
TDD CSI-RS Resource Indicator Reporting – PUSCH 3-1 |
Rel-13 |
C341 |
UE supporting E-UTRA TDD (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.12.1.1 |
FDD CQI reporting under fading conditions for slot/subslot TTI (Cell-Specific Reference Symbol) |
Rel-15 |
C354 |
UE supporting E-UTRA FDD and slot/subslot TTI (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.12.1.2 |
TDD CQI reporting under fading conditions for slot/subslot TTI (Cell-Specific Reference Symbol) |
Rel-15 |
C354a |
UE supporting E-UTRA TDD and slot TTI (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.12.2.1 |
FDD CQI reporting under fading conditions for slot/subslot TTI (CSI Reference Symbol) |
Rel-15 |
C357 |
UE supporting E-UTRA FDD and Feature Group Indicators 103 and slot/subslot TTI (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
9.12.2.2 |
TDD CQI reporting under fading conditions for slot/subslot TTI (CSI Reference Symbol) |
Rel-15 |
C357a |
UE supporting E-UTRA TDD and Feature Group Indicators 103 slot TTI (UE Category >= 2) |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
2Rx, 4Rx |
Note 7 |
||||||||||
MBMS Performance Testing |
|||||||||||||||||
10.1 |
FDD MBMS performance (Fixed Reference Channel) |
Rel-9 |
C03 |
UE supporting E-UTRA FDD and MBMS |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
10.1_1 |
FDD MBMS performance (Fixed Reference Channel) (Release 13 and forward) |
Rel-13 |
C03 |
UE supporting E-UTRA FDD and MBMS |
Performed once |
||||||||||||
10.2 |
TDD MBMS performance (Fixed Reference Channel) |
Rel-9 |
C04 |
UE supporting E-UTRA TDD and MBMS |
Each "Test Number" to be performed once, in a chosen band supporting tested BW |
||||||||||||
10.2_1 |
TDD MBMS performance (Fixed Reference Channel) (Release 13 and forward) |
Rel-13 |
C04 |
UE supporting E-UTRA TDD and MBMS |
Performed once |
||||||||||||
V2X Sidelink Performance Testing |
|||||||||||||||||
14.2 |
Demodulation of PSSCH / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
|||||||||||||
14.3 |
Demodulation of PSCCH / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
|||||||||||||
14.4 |
Power imbalance performance with two links / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
|||||||||||||
14.6 |
Demodulation of PSSCH with eNB based synchronization |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
14.7 |
Soft buffer test |
Rel-14 |
C313 |
UE supporting V2X Sidelink communication |
D14 |
TDD |
|||||||||||
14.8 |
PSCCH/PSSCH decoding capability test / Non-concurrent with E-UTRA uplink transmissions |
Rel-14 |
C321 |
UE supporting V2X Sidelink communication |
|||||||||||||
14.9 |
Sustained downlink data rate with active sidelink |
Rel-14 |
C320 |
UE supporting E-UTRA and V2X Sidelink communication |
E16 |
FDD,TDD |
|||||||||||
Note 1: Due to UE capability signalling for UL 64QAM is introduced from Rel-12, this test case can optionally be executed with a Rel-12 UE. Note 2: For a transition period until RAN5#72, this condition in version 13.0.0 of 36.521-2 shall be used. This is to ensure no test coverage is lost before the UL 64QAM test case becomes available. Note 3: Equivalent aggregated bandwidth is defined as: . Where is number of CCs, and is MIMO layer and bandwidth of CC . The number of MIMO layer for CC in each CA configuration is according to Table A.4.6.1-3, Table A.4.6.2-3, Table A.4.6.3-3, Table A.4.6.3-4 or Table A.4.6.3-5. Note 4: For a transition period until RAN5#83, this condition in version 15.3.1 of 36.521-2 shall be used. This is to ensure no test coverage is lost before the UL 256QAM test cases become available. Note 5: Void. Note 6: The categories for which FGI 103/104 are mandated are (UE category >=11 OR UE DL Category = 11 OR UE DL Category = 12 OR UE DL Category >= 14) according to TS 36.331. The UE DL Categories higher than 14 are not explicitly listed in the corresponding expression in Table 4.1-1a because in this version of core specification UE DL Category > 14 requires supporting of UE Category 11 or 12. Note 7: Skipping 2RX testing if UE is verified with four RX antenna ports in operating bands where it is equipped with four RX antenna port. |
Table 4.1-1a: Applicability of RF conformance test cases Conditions
C01 IF NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/1 THEN R ELSE N/A |
C01h IF (A.4.1-1/1 AND A.4.5-1/18) THEN R ELSE N/A |
C02 IF NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 THEN R ELSE N/A |
C02h IF (A.4.1-1/2 AND A.4.5-1/18) THEN R ELSE N/A |
C03 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/1 AND A.4.2-1/1) THEN R ELSE N/A |
C04 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.2-1/1) THEN R ELSE N/A |
C05 Void |
C06 Void |
C07 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.3-3b/2 AND A.4.2-1/3) THEN R ELSE N/A |
C08 Void |
C09 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/1 AND A.4.3-3a/1) THEN R ELSE N/A |
C10 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.3-3a/1) THEN R ELSE N/A |
C11 IF A.4.1-1/1 AND A.4.3-3a/6 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5) THEN R ELSE N/A |
C12 IF A.4.1-1/2 AND A.4.3-3a/6 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5) THEN R ELSE N/A |
C13 IF ((A.4.1-1/1) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8)) THEN R ELSE N/A |
C13a IF ((A.4.1-1/1) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5)) THEN R ELSE N/A |
C13b IF ((A.4.1-1/1) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12 )) THEN R ELSE N/A |
C14 IF ((A.4.1-1/2) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8)) THEN R ELSE N/A |
C14a IF ((A.4.1-1/2) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5)) THEN R ELSE N/A |
C14b IF ((A.4.1-1/2) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C15 IF (A.4.1-1/1 AND A.4.3-4/1) THEN R ELSE N/A |
C16 IF (A.4.1-1/2 AND A.4.3-4/1) THEN R ELSE N/A |
C17 Void |
C18 Void |
C19 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.1-1/2 AND A.4.6.1-2/2) THEN R ELSE N/A |
C19a IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.1-1/3 AND A.4.6.1-2/3) THEN R ELSE N/A |
C19h IF ((A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.1-1/2 AND A.4.6.1-2/2 AND A.4.5-1/18) THEN R ELSE N/A |
C20 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND (A.4.6.1-1/1 OR A.4.6.1-1/2)) THEN R ELSE N/A |
C20h IF ((A.4.1-1/1 OR A.4.1-1/2) AND (A.4.6.1-1/1 OR A.4.6.1-1/2) AND A.4.5-1/18) THEN R ELSE N/A |
C21 IF (NOT(A.4.3-4a/1 OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.3-1/1) THEN R ELSE N/A |
C21h IF ((A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.3-1/1) AND A.4.5-1/18 THEN R ELSE N/A |
C22 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/1 AND A.4.6.1-1/2) THEN R ELSE N/A |
C23 Void |
C24 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.6.1-1/2) THEN R ELSE N/A |
C25 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1) AND A.4.4-3a/103) THEN R ELSE N/A |
C25m IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1) AND ((A.4.4-3a/103 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C25a IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/2) AND A.4.4-3b/103) THEN R ELSE N/A |
C25am IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/2) AND ((A.4.4-3b/103 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C25b IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1) AND A.4.5-1/81 AND A.4.4-3a/103) THEN R ELSE N/A |
C25bm IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1) AND A.4.5-1/81 AND ((A.4.4-3a/103 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C25c IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/2) AND A.4.5-1/81 AND A.4.4-3b/103) THEN R ELSE N/A |
C25cm IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/2) AND A.4.5-1/81 AND ((A.4.4-3b/103 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C25d IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1) AND A.4.5-1/80 AND A.4.4-3a/103) THEN R ELSE N/A |
C25dm IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1) AND A.4.5-1/80 AND ((A.4.4-3a/103 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C25e IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/2) AND A.4.5-1/80 AND A.4.4-3b/103) THEN R ELSE N/A |
C25em IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/2) AND A.4.5-1/80 AND ((A.4.4-3b/103 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C25h IF (A.4.1-1/1 AND A.4.4-3a/103 AND A.4.5-1/18) THEN R ELSE N/A |
C25hm IF (A.4.1-1/1 AND A.4.5-1/18 AND ((A.4.4-3a/103 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C25x IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 AND A.4.4-3a/103) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C25xm IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/1 AND ((A.4.4-3a/103 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12))) THEN R ELSE N/A |
C25y IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/2 AND A.4.4-3b/103) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C25ym IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND ((A.4.4-3b/103 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12))) THEN R ELSE N/A |
C26 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/2 AND A.4.4-3b/104)) THEN R ELSE N/A |
C26m IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND ((A.4.4-3b/104 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C26a IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.4-3b/104 AND A.4.4-3b/110) THEN R ELSE N/A |
C26am IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.4-3b/110 AND ((A.4.4-3b/104 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C26h IF (((A.4.1-1/1 AND A.4.4-3a/104) OR (A.4.1-1/2 AND A.4.4-3b/104)) AND A.4.5-1/18) THEN R ELSE N/A |
C26hm IF ((((A.4.1-1/1 AND A.4.4-3a/104) OR (A.4.1-1/2 AND A.4.4-3b/104)) AND A.4.5-1/18 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR ((A.4.1-1/1 OR A.4.1-1/2) AND A.4.5-1/18 AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C27 Void |
C28 Void |
C28y IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/2 AND A.4.4-3a/104 AND A.4.4-3a/110) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C28ym IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/2 AND A.4.4-3a/110) AND ((A.4.4-3a/104 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12))) THEN R ELSE N/A |
C29 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/1 AND A.4.4-3a/115) THEN R ELSE N/A |
C30 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.4-3b/115) THEN R ELSE N/A |
C31 IF (A.4.1-1/1 AND (A.4.3-4/1 OR A.4.3-4/2)) THEN R ELSE N/A |
C32 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/1 AND A.4.4-1a/1) THEN R ELSE N/A |
C33 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.4-1b/1) THEN R ELSE N/A |
C34 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.2-1/5) THEN R ELSE N/A |
C35 Void |
C36 IF NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/1 AND A.4.4-1a/2 THEN R ELSE N/A |
C37 IF NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.4-1b/1 THEN R ELSE N/A |
C38 IF NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.4-1b/2 THEN R ELSE N/A |
C39 IF(NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND (A.4.3-3b/1 OR A.4.3-3b/4)) THEN R ELSE N/A |
C39a IF(NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.3-3b/1) THEN R ELSE N/A |
C39b IF(NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.3-3b/4) THEN R ELSE N/A |
C39c IF(NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND (A.4.3-3b/1 OR A.4.3-3b/4) THEN R ELSE N/A |
C40 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/1 AND A.4.4-3a/103 AND A.4.3-7/1) THEN R ELSE N/A |
C40m IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/1 AND A.4.3-7/1 AND ((A.4.4-3a/103 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C41 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.4-3b/103 AND A.4.3-7/1) THEN R ELSE N/A |
C41m IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.3-7/1 AND ((A.4.4-3b/103 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C42 IF ((A.4.1-1/1) AND (NOT A.4.5-1/18) AND (A.4.3-4/6 OR A.4.3-4/7)) THEN R ELSE N/A |
C42h IF ((A.4.1-1/1) AND (A.4.3-4/6 OR A.4.3-4/7) AND A.4.5-1/18 AND A.4.3-4a/8) THEN R ELSE N/A |
C43 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.2-1/1) THEN R ELSE N/A |
C43h IF ((A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.2-1/1 AND A.4.5-1/18) THEN R ELSE N/A |
C44 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/1 AND A.4.3-7/1) THEN R ELSE N/A |
C44z IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/1 AND A.4.3-7/1 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8) AND A.4.4-3a/103) THEN R ELSE N/A |
C45 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.3-7/1) THEN R ELSE N/A |
C45i IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.3-7/1 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8) AND A.4.4-3b/103) THEN R ELSE N/A |
C46 Void |
C47 Void |
C48 Void |
C49 Void |
C50 IF (A.4.1-1/1 AND A.4.5-1/8 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8)) THEN R ELSE N/A |
C50a IF (A.4.1-1/1 AND A.4.5-1/8) THEN R ELSE N/A |
C51 IF (A.4.1-1/2 AND A.4.5-1/8 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8)) THEN R ELSE N/A |
C51a IF (A.4.1-1/2 AND A.4.5-1/8) THEN R ELSE N/A |
C52 IF (A.4.1-1/1 AND (A.4.5-1/11 OR A.4.5-1/12) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8)) THEN R ELSE N/A |
C53 IF (A.4.1-1/2 AND (A.4.5-1/11 OR A.4.5-1/12) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8)) THEN R ELSE N/A |
C54 IF (A.4.1-1/2 AND (A.4.3-4/1 OR A.4.3-4/2)) THEN R ELSE N/A |
C55 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/1 AND A.4.2-1/6) THEN R ELSE N/A |
C56 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.2-1/6) THEN R ELSE N/A |
C57 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/1 AND A.4.2-1/6 AND (A.4.5-1/11 OR A.4.5-1/12)) THEN R ELSE N/A |
C58 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.2-1/6 AND (A.4.5-1/11 OR A.4.5-1/12)) THEN R ELSE N/A |
C59 Void |
C60 Void |
C61 Void |
C62 void |
C63 void |
C64 Void |
C65 Void |
C66 Void |
C67 Void |
C68 Void |
C69 void |
C70 void |
C71 Void |
C72 IF ((A.4.1-1/2) AND (A.4.6.2-1/1) AND (A.4.3-4/3 OR A.4.3-4/4)) THEN R ELSE N/A |
C73 IF ((A.4.1-1/2) AND (NOT A.4.5-1/18) AND (A.4.3-4/6 OR A.4.3-4/7)) THEN R ELSE N/A |
C73h IF ((A.4.1-1/2) AND A.4.5-1/18 AND A.4.3-4a/8) THEN R ELSE N/A |
C74 IF ((A.4.1-1/2) AND (NOT A.4.5-1/18) AND (A.4.6.1-1/1 OR A.4.6.1-1/2 OR A.4.6.3-1/1) AND (A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) THEN R ELSE N/A |
C74h IF ((A.4.1-1/2) AND (A.4.6.1-1/1 OR A.4.6.1-1/2 OR A.4.6.3-1/1) AND A.4.5-1/18 AND (A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/8)) THEN R ELSE N/A |
C75 IF ((A.4.1-1/2) AND (NOT A.4.5-1/18) AND (A.4.6.2-1/1) AND (A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) THEN R ELSE N/A |
C76 IF A.4.1-1/1 AND (NOT A.4.5-1/18) AND (A.4.3-4/1 OR A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4) THEN R ELSE N/A |
C77 IF (A.4.1-1/1 AND A.4.5-2/1 AND A.4.4-3a/115 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8)) THEN R ELSE N/A |
C78 IF (A.4.1-1/2 AND A.4.5-2/1 AND A.4.5-2/2 AND A.4.4-3b/115 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8)) THEN R ELSE N/A |
C79 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/1 AND A.4.5-2/1 AND A.4.4-3a/115) THEN R ELSE N/A |
C80 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.5-2/1 AND A.4.5-2/2 AND A.4.4-3b/115) THEN R ELSE N/A |
C81 void |
C82 void |
C83 IF ((A.4.1-1/2) AND (A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/6 OR A.4.3-4/7) AND (A.4.6.3-1/1)) THEN R ELSE N/A |
C84 void |
C85 Void |
C86 Void |
C87 void |
C88 Void |
C89 Void |
C90 IF ((A.4.1-1/1) AND (A.4.6.2-1/1) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8)) THEN R ELSE N/A |
C91 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/1 AND A.4.2-1/6 AND A.4.4-3a/103) THEN R ELSE N/A |
C91m IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/1 AND A.4.2-1/6 AND ((A.4.4-3a/103 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C92 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.2-1/6 AND A.4.4-3b/103) THEN R ELSE N/A |
C92m IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.2-1/6 AND ((A.4.4-3b/103 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C93 IF ((A.4.1-1/1) AND (NOT A.4.5-1/18) AND (A.4.6.2-1/1) AND (A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) THEN R ELSE N/A |
C94 Void |
C95 void |
C96 IF (A.4.1-1/1 AND A.4.5-1/11) THEN R ELSE N/A |
C97 IF (A.4.1-1/1 AND A.4.5-1/12) THEN R ELSE N/A |
C98 IF (A.4.1-1/2 AND A.4.5-1/11) THEN R ELSE N/A |
C99 IF (A.4.1-1/2 AND A.4.5-1/12) THEN R ELSE N/A |
C100 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.5-1/13) THEN R ELSE N/A |
C101 IF ((A.4.1-1/1) AND (A.4.6.1-1/1 OR A.4.6.1-1/2 or A.4.6.3-1/1) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C102 IF ((A.4.1-1/1) AND (A.4.6.1-1/1 OR A.4.6.1-1/2 OR A.4.6.3-1/1) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C103 IF ((A.4.1-1/1) AND (A.4.6.2-1/1) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C104 IF ((A.4.1-1/1) AND (A.4.6.1-1/1 OR A.4.6.1-1/2 OR A.4.6.3-1/1) AND (A.4.3-4/3 OR A.4.3-4/4)) THEN R ELSE N/A |
C105 IF ((A.4.1-1/2) AND (A.4.6.1-1/1 OR A.4.6.1-1/2 OR A.4.6.3-1/1) AND (A.4.3-4/3 OR A.4.3-4/4)) THEN R ELSE N/A |
C106 IF ((A.4.1-1/1) AND (A.4.6.2-1/1) AND (A.4.3-4/3 OR A.4.3-4/4)) THEN R ELSE N/A |
C107 IF ((A.4.1-1/1) AND (NOT A.4.5-1/18) AND (A.4.6.1-1/1 OR A.4.6.1-1/2 OR A.4.6.3-1/1) AND (A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) THEN R ELSE N/A |
C107h IF ((A.4.1-1/1) AND (A.4.6.1-1/1 OR A.4.6.1-1/2 OR A.4.6.3-1/1) AND A.4.5-1/18 AND (A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/8)) THEN R ELSE N/A |
C108 IF ((A.4.1-1/1) AND (A.4.6.1-1/1 OR A.4.6.1-1/2 OR A.4.6.3-1/1) AND (A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8)) THEN R ELSE N/A |
C109 IF (A.4.1-1/2 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8) AND (A.4.6.2-1/1 OR A.4.6.3-1/1)) THEN R ELSE N/A |
C110 IF (A.4.1-1/2 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8) AND (A.4.6.1-1/1 OR A.4.6.1-1/2)) THEN R ELSE N/A |
C111 IF A.4.1-1/2 AND (NOT A.4.5-1/18) AND (A.4.3-4/1 OR A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4) THEN R ELSE N/A |
C112 IF ((A.4.1-1/1 OR A.4.1-1/2) AND A.4.3-4a/1) THEN R ELSE N/A |
C112a IF ((A.4.1-1/1 OR A.4.1-1/2) AND A.4.3-4aa/1) THEN R ELSE N/A |
C112b IF (A.4.1-1/8 OR A.4.1-1/8a) THEN R ELSE N/A |
C112c IF ((A.4.1-1/1 OR A.4.1-1/2) AND( A.4.3-4a/1a OR A.4.3-4b/1a)) THEN R ELSE N/A |
C112d IF ((A.4.1-1/1 OR A.4.1-1/2) AND A.4.3-4aa/1 AND A.4.3-4aa/2) THEN R ELSE N/A |
C113 IF (A.4.1-1/1 OR A.4.1-1/2) AND NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) THEN R ELSE N/A |
C113a IF (A.4.5-1/22) THEN R ELSE N/A |
C113b IF (A.4.1-1/1 AND A.4.5-1/37) THEN R ELSE N/A |
C113c IF (A.4.1-1/1 AND A.4.5-1/37 AND A.4.4-3a/103) THEN R ELSE N/A |
C113cm IF (A.4.1-1/1 AND A.4.5-1/37 AND ((A.4.4-3a/103 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C113d IF (A.4.1-1/1 AND A.4.5-1/37 AND A.4.3-7/1) THEN R ELSE N/A |
C113e IF (A.4.1-1/1 AND A.4.5-1/37 AND A.4.3-7/1 AND A.4.4-3a/103) THEN R ELSE N/A |
C113em IF (A.4.1-1/1 AND A.4.5-1/37 AND A.4.3-7/1 AND ((A.4.4-3a/103 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C113h IF (A.4.5-1/18) THEN R ELSE N/A |
C114 IF (A.4.1-1/2 AND A.4.6.1-1/2) AND (A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10) THEN R ELSE N/A |
C115 IF ((A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.2-1/1 AND A.4.6.2-2/1) THEN R ELSE N/A |
C116 IF ((A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.3-1/1 AND A.4.6.3-2/1) THEN R ELSE N/A |
C116a IF ((A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.3-1/3 AND A.4.6.3-2/2) THEN R ELSE N/A |
C116b IF (A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.3-1/1 AND A.4.6.3-2/1 AND NOT (A.4.5-1/17 OR A.4.5-1/58) THEN R ELSE N/A |
C117 IF (A.4.1-1/1 AND (A.4.5-1/8 OR A.4.5-1/11 OR A.4.5-1/12) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8)) THEN R ELSE N/A |
C118 IF (A.4.1-1/2 AND (A.4.5-1/8 OR A.4.5-1/11 OR A.4.5-1/12) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8)) THEN R ELSE N/A |
C119 IF A.4.1-1/2 AND A.4.3-4a/1 THEN R ELSE N/A |
C120 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.3-1/5) THEN R ELSE N/A |
C121 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND (A.4.6.1-1/3 OR A.4.6.3-1/3 OR A.4.6.3-1/4)) THEN R ELSE N/A |
C122 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND (A.4.6.3-1/2 OR A.4.6.2-1/2)) THEN R ELSE N/A |
C122h IF ((A.4.1-1/1 OR A.4.1-1/2) AND (A.4.6.1-1/3 OR A.4.6.3-1/3 OR A.4.6.3-1/4 OR A.4.6.3-1/2 OR A.4.6.2-1/2)) AND A.4.5-1/18 THEN R ELSE N/A |
C123 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/2) THEN R ELSE N/A |
C124 IF (A.4.1-1/1 AND (A.4.6.1-1/3 OR A.4.6.3-1/3 OR A.4.6.3-1/4) AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C125 IF (A.4.1-1/1 AND (A.4.6.3-1/2 OR A.4.6.2-1/2) AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C125a IF (A.4.1-1/1 AND (A.4.6-1/2 OR A.4.6-1/3 OR A.4.6-1/4 OR A.4.6-1/5 OR A.4.6-1/6) AND A.4.6.1-1/2 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C126 IF (A.4.1-1/1 AND (NOT A.4.5-1/18) AND (A.4.6.1-1/3 OR A.4.6.3-1/3 OR A.4.6.3-1/4) AND (A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C126a IF (A.4.1-1/1 AND (NOT A.4.5-1/18) AND (A.4.6.1-1/3 OR A.4.6.3-1/3 OR A.4.6.3-1/4) AND (A.4.3-4/6 OR A.4.3-4/7) AND A.4.3-3a/9) THEN R ELSE N/A |
C126h IF (A.4.1-1/1 AND (A.4.6.1-1/3 OR A.4.6.3-1/3 OR A.4.6.3-1/4) AND A.4.5-1/18 AND (A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/10)) THEN R ELSE N/A |
C126ha IF (A.4.1-1/1 AND (A.4.6.1-1/3 OR A.4.6.3-1/3 OR A.4.6.3-1/4) AND A.4.5-1/18 AND ( A.4.3-4a/8) AND A.4.3-3a/9) THEN R ELSE N/A |
C127 IF (A.4.1-1/1 AND (NOT A.4.5-1/18) AND (A.4.6.3-1/2 OR A.4.6.2-1/2) AND (A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C127a IF (A.4.1-1/1 AND (NOT A.4.5-1/18) AND (A.4.6.3-1/2 OR A.4.6.2-1/2) AND (A.4.3-4/6 OR A.4.3-4/7) AND A.4.3-3a/9) THEN R ELSE N/A |
C128 IF (A.4.1-1/2 AND (A.4.6.1-1/3 OR A.4.6.3-1/3 OR A.4.6.3-1/4) AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C129 IF (A.4.1-1/2 AND (A.4.6.3-1/2 OR A.4.6.2-1/2) AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C130 IF (A.4.1-1/2 AND (NOT A.4.5-1/18) AND (A.4.6.1-1/3 OR A.4.6.3-1/3 OR A.4.6.3-1/4) AND (A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C130h IF (A.4.1-1/2 AND (A.4.6.1-1/3 OR A.4.6.3-1/3 OR A.4.6.3-1/4) AND A.4.5-1/18 AND (A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/10)) THEN R ELSE N/A |
C131 IF (A.4.1-1/2 AND (NOT A.4.5-1/18) AND (A.4.6.3-1/2 OR A.4.6.2-1/2) AND (A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C132 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/1 AND A.4.5-1/15 AND (A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C133 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/2 AND A.4.5-1/15 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C133a IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/3 AND A.4.5-1/15 AND (A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C133b IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/4 AND A.4.5-1/15 AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C134 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/1 AND A.4.5-1/14 AND (A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C135 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/2 AND A.4.5-1/14 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C135a IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/3 AND A.4.5-1/14 AND (A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C135b IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/4 AND A.4.5-1/14 AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C136 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/1 AND A.4.5-1/15 AND (A.4.3-4/3 OR A.4.3-4/4)) THEN R ELSE N/A |
C137 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/1 AND A.4.5-1/14 AND (A.4.3-4/3 OR A.4.3-4/4)) THEN R ELSE N/A |
C138 IF (A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/1 AND A.4.5-1/15 AND (NOT A.4.5-1/18) AND (A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10) THEN R ELSE N/A |
C138h IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/1 AND A.4.5-1/15 AND A.4.5-1/18 AND (A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/10)) THEN R ELSE N/A |
C139 IF (A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/2 AND A.4.5-1/15 AND (NOT A.4.5-1/18) AND (A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12) THEN R ELSE N/A |
C139a IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/3 AND A.4.5-1/15 AND (NOT A.4.5-1/18) AND (A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C139b IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/4 AND A.4.5-1/15 AND (NOT A.4.5-1/18) AND A.4.3-4a/10) THEN R ELSE N/A |
C139c IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.5-1/15 AND (NOT A.4.5-1/18) AND A.4.3-4a/10 AND (A.4.6.3-1/19 OR A.4.6.3-1/20 OR A.4.6.3-1/21 OR A.4.6.3-1/22 OR A.4.6.3-1/23)) THEN R ELSE N/A |
C139hc IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.5-1/15 AND A.4.5-1/18 AND (A.4.3-4a/11) AND (A.4.6.3-1/19 OR A.4.6.3-1/20 OR A.4.6.3-1/21 OR A.4.6.3-1/22 OR A.4.6.3-1/23)) THEN R ELSE N/A |
C139h IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/2 AND A.4.5-1/15 AND A.4.5-1/18 AND (A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/10)) THEN R ELSE N/A |
C139ha IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/3 AND A.4.5-1/15 AND A.4.5-1/18 AND (A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/10)) THEN R ELSE N/A |
C139hb IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/4 AND A.4.5-1/15 AND A.4.5-1/18 AND (A.4.3-4a/11)) THEN R ELSE N/A |
C140 IF (A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/1 AND A.4.5-1/14 AND (NOT A.4.5-1/18) AND (A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10) THEN R ELSE N/A |
C140h IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/1 AND A.4.5-1/14 AND A.4.5-1/18 AND (A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/8)) THEN R ELSE N/A |
C141 IF (A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/2 AND A.4.5-1/14 AND (NOT A.4.5-1/18) AND (A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12) THEN R ELSE N/A |
C141a IF (A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/3 AND A.4.5-1/14 AND (NOT A.4.5-1/18) AND (A.4.3-4/11 OR A.4.3-4/12) THEN R ELSE N/A |
C141b IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/4 AND A.4.5-1/14 AND (NOT A.4.5-1/18) AND A.4.3-4a/10 THEN R ELSE N/A) |
C141c IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.5-1/14 AND (NOT A.4.5-1/18) AND A.4.3-4a/10 AND (A.4.6.3-1/19 OR A.4.6.3-1/20 OR A.4.6.3-1/21 OR A.4.6.3-1/22 OR A.4.6.3-1/23)) THEN R ELSE N/A) |
C141h IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/2 AND A.4.5-1/14 AND A.4.5-1/18 AND (A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/10)) THEN R ELSE N/A |
C141hb IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/2 AND A.4.5-1/14 AND A.4.5-1/18 AND A.4.3-4a/11) THEN R ELSE N/A |
C142 IF (NOT(A.4.3-4/1 OR A.4.3-4a/1 OR A.4.3-4aa/1) AND A.4.1-1/1 AND A.4.3-7/3) THEN R ELSE N/A |
C142h IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.5-1/14 AND A.4.5-1/18 AND A.4.3-4a/11 AND (A.4.6.3-1/19 OR A.4.6.3-1/20 OR A.4.6.3-1/21 OR A.4.6.3-1/22 OR A.4.6.3-1/23)) THEN R ELSE N/A |
C143 IF (NOT(A.4.3-4/1 OR A.4.3-4a/1 OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.3-7/3) THEN R ELSE N/A |
C144 IF (NOT(A.4.3-4/1 OR A.4.3-4a/1 OR A.4.3-4aa/1) AND A.4.1-1/1 AND A.4.3-7/3 AND A.4.4-3a/103) THEN R ELSE N/A |
C144m IF (NOT(A.4.3-4/1 OR A.4.3-4a/1 OR A.4.3-4aa/1) AND A.4.1-1/1 AND A.4.3-7/3 AND ((A.4.4-3a/103 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C145 IF A.4.1-1/1 AND A.4.3-4a/1 THEN R ELSE N/A |
C145a IF A.4.1-1/1 AND A.4.3-4aa/1 THEN R ELSE N/A |
C145b IF A.4.1-1/1 AND (A.4.3-4aa/1 OR A.4.5-1/25) THEN R ELSE N/A |
C145c Void |
C145d IF A.4.1-1/1 AND A.4.3-4a/1a THEN R ELSE N/A |
C145e IF A.4.1-1/1 AND A.4.3-4aa/1 AND A.4.5-1/63 THEN R ELSE N/A |
C145f IF A.4.1-1/1 AND A.4.3-4aa/2 AND A.4.5-1/63 THEN R ELSE N/A |
C145g IF A.4.1-1/1 AND A.4.3-4aa/1 AND A.4.5-1/51 THEN R ELSE N/A |
C145h IF A.4.1-1/1 AND A.4.3-4aa/2 AND A.4.5-1/51 THEN R ELSE N/A |
C145i IF A.4.1-1/1 AND A.4.5-1/25 AND A.4.5-1/84 THEN R ELSE N/A |
C145j IF A.4.1-1/1 AND A.4.5-1/25 AND A.4.5-1/85 THEN R ELSE N/A |
C145k IF (A.4.1-1/1 or A.4.3-7/2) AND A.4.5-1/25 THEN R ELSE N/A |
C146 IF (NOT(A.4.3-4a/1) AND (A.4.1-1/1 AND A.4.1-1/2) AND A.4.6.3-1/1 AND (A.4.5-1/14 OR A.4.5-1/15)) THEN R ELSE N/A |
C147 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.5-1/17) THEN R ELSE N/A |
C148 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.1-1/2 AND A.4.6.1-2/2 AND A.4.5-1/17) THEN R ELSE N/A |
C149 IF (NOT(A.4.3-4a/1 OR A.4.3-4aa/1 OR A.4.5-1/58) AND A.4.1-1/1 AND A.4.5-1/13 AND A.4.5-1/17) THEN R ELSE N/A |
C150 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/1 AND A.4.3-7/4) THEN R ELSE N/A |
C151 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.3-7/4) THEN R ELSE N/A |
C152 IF (NOT(A.4.3-4/1 OR A.4.3-4a/1 OR A.4.3-4aa/1) AND A.4.1-1/1 AND A.4.3-7/4) THEN R ELSE N/A |
C153 IF (NOT(A.4.3-4/1 OR A.4.3-4a/1 OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.3-7/4) THEN R ELSE N/A |
C154 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/1 AND A.4.5-1/15 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C155 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/1 AND A.4.5-1/14 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C156 IF A.4.1-1/2 AND A.4.3-4a/1 THEN R ELSE N/A |
C156a IF A.4.1-1/2 AND A.4.3-4aa/1 THEN R ELSE N/A |
C156b IF A.4.1-1/2 AND (A.4.3-4aa/1 OR A.4.5-1/25) THEN R ELSE N/A |
C156c IF A.4.1-1/1 AND (A.4.3-4aa/1 AND A.4.5-1/26 THEN R ELSE N/A |
C156d IF A.4.1-1/2 AND (A.4.3-4aa/1 AND A.4.5-1/26 THEN R ELSE N/A |
C156e IF A.4.1-1/2 AND (A.4.3-4aa/1 OR A.4.5-1/25) AND A.4.5-1/51 THEN R ELSE N/A |
C156f IF A.4.1-1/2 AND A.4.3-4a/1a THEN R ELSE N/A |
C156q IF A.4.1-1/2 AND (A.4.3-4aa/1 OR A.4.5-1/25) AND A.4.5-1/63 THEN R ELSE N/A |
C156h IF A.4.1-1/2 AND A.4.3-4aa/2 AND A.4.5.1/63 THEN R ELSE N/A |
C156i IF A.4.1-1/2 AND A.4.3-4aa/2 AND A.4.5.1/51 THEN R ELSE N/A |
C156j IF A.4.1-1/1 AND (A.4.3-4aa/1 AND A.4.3-4aa/2) AND A.4.5-1/26 THEN R ELSE N/A |
C156k IF A.4.1-1/2 AND A.4.5-1/25 AND A.4.5-1/84 THEN R ELSE N/A |
C156l IF A.4.1-1/2 AND A.4.5-1/25 AND A.4.5-1/85 THEN R ELSE N/A |
C157 IF A.4.1-1/1 AND A.4.3-4a/1 AND A.4.4-3a/103 THEN R ELSE N/A |
C157a IF A.4.1-1/1 AND A.4.3-4a/1a AND A.4.4-3a/103 THEN R ELSE N/A |
C158 IF A.4.1-1/2 AND A.4.3-4a/1 AND A.4.4-3b/103 THEN R ELSE N/A |
C158a IF A.4.1-1/2 AND A.4.3-4a/1a AND A.4.4-3b/103 THEN R ELSE N/A |
C159 IF (NOT(A.4.3-4a/1 OR A.4.5-1/17 OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.5-1/13) THEN R ELSE N/A |
C160 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.3-1/1 AND A.4.6.3-2/1 AND A.4.5-1/17) THEN R ELSE N/A |
C161 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.2-1/1 AND A.4.6.2-2/1 AND A.4.5-1/17) THEN R ELSE N/A |
C162 IF A.4.5-1/23 THEN R ELSE N/A |
C163 IF A.4.5-1/24 THEN R ELSE N/A |
C164 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.2-1/6 AND A.4.5-1/37) THEN R ELSE N/A |
C165 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.2-1/6 AND A.4.5-1/38) THEN R ELSE N/A |
C166 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.2-1/6 AND A.4.4-3a/103 AND A.4.5-1/37) THEN R ELSE N/A |
C166m IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.2-1/6 AND A.4.5-1/37 AND ((A.4.4-3a/103 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C167 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.2-1/6 AND A.4.4-3a/103 AND A.4.5-1/38) THEN R ELSE N/A |
C167m IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.2-1/6 AND A.4.5-1/38 AND ((A.4.4-3a/103 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C168 IF (A.4.5-1/22 AND NOT A.4.5-1/18) THEN R ELSE N/A |
C169 IF A.4.1-1/1 AND A.4.2-1/8 AND NOT (A.4.3-4/1 OR A.4.3-4/2 OR A.4.3-4a/1) THEN R ELSE N/A |
C170 IF A.4.1-1/2 AND A.4.2-1/8 AND NOT (A.4.3-4/1 OR A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4a/1) THEN R ELSE N/A |
C171 IF A.4.1-1/1 AND A.4.2-1/8 AND (A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10) AND (NOT A.4.5-1/18) THEN R ELSE N/A |
C172 IF A.4.1-1/2 AND A.4.2-1/8 AND (A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10) AND (NOT A.4.5-1/18) THEN R ELSE N/A |
C173 IF A.4.1-1/1 AND A.4.2-1/8 AND A.4.5-1/18 THEN R ELSE N/A |
C174 IF A.4.1-1/2 AND A.4.2-1/8 AND A.4.5-1/18 THEN R ELSE N/A |
C175 IF (NOT(A.4.3-4a/1) AND A.4.1-1/1 AND A.4.5-1/12 AND A.4.3-7/4) THEN R ELSE N/A |
C176 IF (NOT(A.4.3-4a/1) AND A.4.1-1/2 AND A.4.5-1/12 AND A.4.3-7/4) THEN R ELSE N |
C177 IF (A.4.5-1/38) THEN R ELSE N/A |
C178 IF (A.4.4-3a/103 AND A.4.5-1/37 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C178m IF (A.4.5-1/37 AND ((A.4.4-3a/103 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12))) THEN R ELSE N/A |
C179 IF (A.4.4-3a/104 AND A.4.5-1/38 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C179m IF (A.4.5-1/38 AND ((A.4.4-3a/104 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12))) THEN R ELSE N/A |
C180 IF (A.4.5-1/37 AND A.4.5-1/46 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C181 IF (A.4.5-1/38 AND A A.4.5-1/46 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C182 IF (A.4.4-3a/103 AND A.4.5-1/37 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C182m IF (A.4.5-1/37 AND ((A.4.4-3a/103 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12))) THEN R ELSE N/A |
C183 IF (A.4.4-3b/103 AND A.4.5-1/38 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C183m IF (A.4.5-1/38 AND ((A.4.4-3b/103 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12))) THEN R ELSE N/A |
C184 IF (A.4.5-1/38) THEN R ELSE N/A |
C185 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.2-1/1 AND A.4.6.2-2/1 AND A.4.5-1/17) THEN R ELSE N/A |
C186 IF A.4.3-3b/2 AND NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) THEN R ELSE N/A |
C187 IF ((A.4.1-1/1 OR A.4.1-1/2) AND ((A.4.1-1/2 AND A.4.6.1-1/4) OR A.4.6.3-1/6 OR A.4.6.3-1/7)) THEN R ELSE N/A |
C187h IF (A.4.1-1/1 OR A.4.1-1/2) AND ((A.4.1-1/2 AND A.4.6.1-1/4) OR ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/3) OR A.4.6.3-1/6 OR A.4.6.3-1/7 OR A.4.6.3-1/9 OR A.4.6.3-1/10 OR A.4.6.3-1/11 OR A.4.6.3-1/12) AND A.4.5-1/18 THEN R ELSE N/A |
C188 IF (A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/3 THEN R ELSE N/A |
C189 IF (A.4.1-1/1 AND (NOT A.4.5-1/18) AND (A.4.6-1/3) AND (A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C189a IF (A.4.1-1/1 AND (NOT A.4.5-1/18) AND (A.4.6-1/3) AND (A.4.3-4/9 OR A.4.3-4/10) AND A.4.3-3a/10) THEN R ELSE N/A |
C189a2 Void |
C189b Void |
C189h IF A.4.1-1/1 AND A.4.5-1/18 AND (A.4.3-4a/10 OR A.4.3-4a/11) AND A.4.6-1/3 AND A.4.3-3a/10 AND (A.4.6.1-1/4 OR A.4.6.2-1/4 OR A.4.6.2-1/5 OR A.4.6.3-1/6 OR A.4.6.3-1/7) THEN R ELSE N/A |
C190 Void |
C191 Void |
C192 IF (A.4.1-1/1 AND (A.4.6.1-1/4 OR A.4.6.3-1/6 OR A.4.6.3-1/7) AND (A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C192a IF (A.4.1-1/1 AND (NOT A.4.5-1/18) AND (A.4.6.2-1/6 OR A.4.6.2-1/7 OR A.4.6.2-1/8 OR A.4.6.3-1/8 OR A.4.6.3-1/13 OR A.4.6.3-1/15 OR A.4.6.3-1/16 OR A.4.6.3-1/17) AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C193 IF (A.4.1-1/1 AND (A.4.6.3-1/10 OR A4.6.3-1/11 OR A.4.6.3-1/12) AND (A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C193a IF (A.4.1-1/1 AND (NOT A.4.5-1/18) AND A.4.6.3-1/14 AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C194 IF (A.4.1-1/2 AND (A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12) AND (A.4.6.1-1/4 OR A.4.6.2-1/4 OR 4.6.2-1/5 OR A.4.6.3-1/6 OR A.4.6.3-1/7 OR A.4.6.3-1/9 OR A.4.6.3-1/10 OR A.4.6.3-1/11 OR A.4.6.3-1/12)) THEN R ELSE N/A |
C194a IF (A.4.1-1/2 AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12) AND (A.4.6.2-1/6 OR 4.6.2-1/7 OR A.4.6.3-1/8 OR A.4.6.3-1/13 OR A.4.6.3-1/15 OR A.4.6.3-1/16 OR A.4.6.3-1/17 OR A.4.6.3-1/18)) THEN R ELSE N/A |
C194b IF (A.4.1-1/2 AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12) AND (A.4.6.1-1/5 OR A.4.6.3-1/14)) THEN R ELSE N/A |
C195 Void |
C196 Void |
C197 IF (A.4.5-1/37 AND A.4.3-7/1) THEN R ELSE N/A |
C198 IF (A.4.5-1/38 AND A.4.3-7/1) THEN R ELSE N/A |
C198a IF A.4.1-1/2 AND A.4.5-1/38 AND A.4.3-7/1 THEN R ELSE N/A |
C198b IF (A.4.4-3b/103 AND A.4.5-1/38 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C198c IF A.4.1-1/2 AND A.4.5-1/38 AND A.4.3-7/1 AND A.4.4-3b/103 THEN R ELSE N/A |
C199 IF A.4.5-1/37 AND A.4.3-7/1 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12) AND A.4.4-3a/103 THEN R ELSE N/A |
C199m IF A.4.5-1/37 AND A.4.3-7/1 AND ((A.4.4-3a/103 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C200 IF A.4.5-1/38 AND A.4.3-7/1 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12) AND A.4.4-3b/103 THEN R ELSE N/A |
C200m IF A.4.5-1/38 AND A.4.3-7/1 AND ((A.4.4-3b/103 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C201 Void |
C202 IF ((NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.3-3b/4 AND A.4.2-1/3) THEN R ELSE N/A |
C203 IF ((A.4.5-1/37) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12 )) THEN R ELSE N/A |
C204 IF ((A.4.5-1/38) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12 )) THEN R ELSE N/A |
C205 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 AND A.4.4-3a/103 AND A.4.5-1/37) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C205m IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 AND A.4.5-1/37) AND ((A.4.4-3a/103 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12))) THEN R ELSE N/A |
C206 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/2 AND A.4.4-3b/103 AND A.4.5-1/38) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C206m IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/2 AND A.4.5-1/38) AND ((A.4.4-3b/103 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12))) THEN R ELSE N/A |
C207 IF (NOT(A.4.3-4a/1 OR A.4.3-4aa/1) AND (A.4.1-1/1 AND A.4.1-1/2) AND A.4.6.3-1/1 AND (A.4.5-1/14 OR A.4.5-1/15) AND A.4.5-1/32) THEN R ELSE N/A |
C208 IF (NOT(A.4.3-4a/1 OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.3-1/1 AND A.4.5-1/32) THEN R ELSE N/A |
C209 IF A.4.1-1/1 AND A.4.5-1/15 AND A.4.5-1/32 THEN R ELSE N/A |
C210 IF A.4.1-1/2 AND A.4.5-1/14 AND A.4.5-1/32 THEN R ELSE N/A |
C211 IF (A.4.1-1/1 OR A.4.1-1/2) AND (A.4.6.3-1/6 OR A.4.6.3-1/7 OR A.4.6.3-1/9 OR A.4.6.3-1/10 OR A.4.6.3-1/11 OR A.4.6.3-1/12) THEN R ELSE N/A |
C212 IF (A.4.1-1/1 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12) AND (A.4.6.3-1/6 OR A.4.6.3-1/7 OR A.4.6.3-1/9 OR A.4.6.3-1/10 OR A.4.6.3-1/11 OR A.4.6.3-1/12)) THEN R ELSE N/A |
C212a IF (A.4.1-1/1 AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12) AND (A.4.6.3-1/13 OR A.4.6.3-1/15 OR A.4.6.3-1/16 OR A.4.6.3-1/17 OR A.4.6.3-1/18 OR A.4.6.2-1/6 OR A.4.6.2-1/7 OR A.4.6.2-1/8)) THEN R ELSE N/A |
C212b IF (A.4.1-1/1 AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12) AND (A.4.6.3-1/14)) THEN R ELSE N/A |
C213 IF (A.4.1-1/2 AND (NOT A.4.5-1/18) AND (A.4.6-1/3 OR A.4.6.1-1/4 OR A.4.6.2-1/4 OR A.4.6.2-1/5 OR A.4.6.3-1/6 OR A.4.6.3-1/7 OR A.4.6.3-1/9 OR A.4.6.3-1/10 OR A.4.6.3-1/11 OR A.4.6.3-1/12) AND (A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/10)) THEN R ELSE N/A |
C213h IF (A.4.1-1/2 AND A.4.5-1/18 AND (A.4.6-1/3 OR A.4.6.1-1/4 OR A.4.6.2-1/4 OR A.4.6.2-1/5 OR A.4.6.3-1/6 OR A.4.6.3-1/7 OR A.4.6.3-1/9 OR A.4.6.3-1/10 OR A.4.6.3-1/11 OR A.4.6.3-1/12) AND (A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/10 OR A.4.3-4a/11)) THEN R ELSE N/A |
C214 IF (A.4.1-1/1 AND (A.4.6.3-1/6 OR A.4.6.3-1/7 OR A.4.6.3-1/10 OR A.4.6.2-1/4 OR A.4.6.2-1/5) AND (A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C215 IF (A.4.1-1/1 AND (A.4.6.3-1/8 OR A.4.6.3-1/13 OR A.4.6.3-1/15) AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C216 IF (A.4.1-1/1 AND A.4.6.3-1/14 AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C217 IF A.4.1-1/2 AND A.4.5-1/15 AND A.4.5-1/32 THEN R ELSE N/A |
C218 IF A.4.1-1/1 AND A.4.5-1/15 AND A.4.5-1/32 AND A.4.5-1/56 THEN R ELSE N/A |
C219 IF A.4.1-1/2 AND A.4.5-1/32 AND A.4.5-1/56 THEN R ELSE N/A |
C220 IF A.4.1-1/1 AND (A.4.5-1/37 AND A.4.5-1/46) THEN R ELSE N/A |
C221 IF (A.4.1-1/1 OR A.4.1-1/2) AND (A.4.6.3-1/13 OR A.4.6.3-1/15 OR A.4.6.3-1/16 OR A.4.6.3-1/17 OR A.4.6.3-1/18 OR A.4.6.2-1/6 OR A.4.6.2-1/7 OR A.4.6.2-1/8) THEN R ELSE N/A |
C221h IF (A.4.1-1/1 OR A.4.1-1/2) AND (A.4.6.3-1/13 OR A.4.6.3-1/14 OR A.4.6.3-1/15 OR A.4.6.3-1/16 OR A.4.6.3-1/17 OR A.4.6.3-1/18 OR A.4.6.2-1/6 OR A.4.6.2-1/7 OR A.4.6.2-1/8 OR (A.4.1-1/2 AND A.4.6.1-1/5) OR ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/4)) AND A.4.5-1/18 THEN R ELSE N/A |
C222 IF ((A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.3-1/14) OR (A.4.1-1/2 AND A.4.6.1-1/5) THEN R ELSE N/A |
C223 IF (A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/4 THEN R ELSE N/A |
C224 IF A.4.2-1/8 THEN R ELSE N/A |
C225 IF (A.4.2-1/8 AND A.4.5-1/27) THEN R ELSE N/A |
C226 IF (A.4.1-1/1 AND A.4.5-1/37 AND A.4.5-1/46 AND (A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4a/8)) THEN R ELSE N/A |
C227 IF (A.4.5-8/1 AND (A.4.6.1-1/1 OR A.4.6.1-1/2 OR A.4.6.3-1/1) AND (A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/4 OR A.4.3-4a/5 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/10)) THEN R ELSE N/A |
C228 IF (A.4.5-8/1 AND A.4.6.2-1/1 AND (A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/4 OR A.4.3-4a/5 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/10)) THEN R ELSE N/A |
C229 IF (A.4.5-8/4 AND (A.4.6.1-1/3 OR A.4.6.3-1/3 OR A.4.6.3-1/4) AND (A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/10 OR A.4.3-4a/11 OR A.4.3-4a/13)) THEN R ELSE N/A |
C230 IF (A.4.5-8/4 AND (A.4.6.3-1/2 OR A.4.6.2-1/2) AND (A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/10 OR A.4.3-4a/11 OR A.4.3-4a/13)) THEN R ELSE N/A |
C231 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/1 AND A.4.5-1/15 AND (A.4.5-1/37 OR A.4.5-1/38) AND A.4.3-7/1 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C232 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/1 AND A.4.5-1/14 AND (A.4.5-1/37 OR A.4.5-1/38) AND A.4.3-7/1 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C233 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/1 AND A.4.5-1/15 AND (A.4.4-3a/103 AND A.4.4-3b/103) AND (A.4.5-1/37 OR A.4.5-1/38) AND A.4.3-7/1 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C233m IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/1 AND A.4.5-1/15 AND (A.4.5-1/37 OR A.4.5-1/38) AND A.4.3-7/1 AND (((A.4.4-3a/103 AND A.4.4-3b/103) AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12))) THEN R ELSE N/A |
C234 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/1 AND A.4.5-1/14 AND (A.4.4-3a/103 AND A.4.4-3b/103) AND (A.4.5-1/37 OR A.4.5-1/38) AND A.4.3-7/1 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C234m IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/1 AND A.4.5-1/14 AND (A.4.5-1/37 OR A.4.5-1/38) AND A.4.3-7/1 AND (((A.4.4-3a/103 AND A.4.4-3b/103) AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12))) THEN R ELSE N/A |
C235 IF A.4.1-1/2 AND (A.4.5-1/38 AND A.4.5-1/46) THEN R ELSE N/A |
C236 IF (A.4.5-8/7 AND (A.4.6.1-1/4 OR A.4.6.2-1/4 OR A.4.6.2-1/5 OR A.4.6.3-1/6 OR A.4.6.3-1/7 OR A.4.6.3-1/9 OR A.4.6.3-1/10 OR A.4.6.3-1/11 OR A.4.6.3-1/12) AND (A.4.3-4a/10 OR A.4.3-4a/11 OR A.4.3-4a/13 OR A.4.3-4a/14)) THEN R ELSE N/A |
C237 IF (A.4.5-8/10 AND (A.4.6.1-1/5 OR A.4.6.2-1/6 OR A.4.6.2-1/7 OR A.4.6.2-1/8 OR A.4.6.3-1/8 OR A.4.6.3-1/13 OR A.4.6.3-1/15 OR A.4.6.3-1/16 OR A.4.6.3-1/17) AND (A.4.3-4a/10 OR A.4.3-4a/11 OR A.4.3-4a/13 OR A.4.3-4a/14)) THEN R ELSE N/A |
C238 IF (A.4.5-8/10 AND A.4.6.3-1/14 AND (A.4.3-4a/10 OR A.4.3-4a/11 OR A.4.3-4a/13 OR A.4.3-4a/14)) THEN R ELSE N/A |
C239 IF (A.4.1-1/2 AND A.4.5-1/38 AND A.4.5-1/46 AND (A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4a/8)) THEN R ELSE N/A |
C240 IF (A.4.5-8/2 AND (A.4.6.1-1/1 OR A.4.6.1-1/2 OR A.4.6.3-1/1 OR A.4.6.3-1/5) AND (A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4a/8)) THEN R ELSE N/A |
C241 IF (A.4.5-8/2 AND A.4.6.1-2/1 AND (A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4a/8)) THEN R ELSE N/A |
C242 IF (A.4.5-8/5 AND (A.4.6.1-1/3 OR A.4.6.3-1/3 OR A.4.6.3-1/4) AND (A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/10 OR A.4.3-4a/11 OR A.4.3-4a/13)) THEN R ELSE N/A |
C243 IF (A.4.5-8/5 AND (A.4.6. 2-1/2 OR A.4.6.3-1/2) AND (A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/10 OR A.4.3-4a/11 OR A.4.3-4a/13)) THEN R ELSE N/A |
C244 IF (A.4.5-8/8 AND (A.4.6.1-1/4 OR A.4.6.2-1/4 OR A.4.6.2-1/5 OR A.4.6.3-1/6 OR A.4.6.3-1/7 OR A.4.6.3-1/9 OR A.4.6.3-1/10 OR A.4.6.3-1/11 OR A.4.6.3-1/12) AND (A.4.3-4a/11 OR A.4.3-4a/13 OR A.4.3-4a/14)) THEN R ELSE N/A |
C245 IF (A.4.5-8/11 AND (A.4.6.1-1/5 OR A.4.6.2-1/6 OR A.4.6.2-1/7 OR A.4.6.2-1/8 OR A.4.6.3-1/8 OR A.4.6.3-1/13 OR A.4.6.3-1/15 OR A.4.6.3-1/16 OR A.4.6.3-1/17) AND (A.4.3-4a/13 OR A.4.3-4a/14)) THEN R ELSE N/A |
C246 IF (A.4.5-8/11 AND A.4.6.3-1/14 AND (A.4.3-4a/13 OR A.4.3-4a/14)) THEN R ELSE N/A |
C247 IF (A.4.5-8/3 AND (A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/4 OR A.4.3-4a/5 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/10)) THEN R ELSE N/A |
C248 IF (A.4.5-8/6 AND (A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/10 OR A.4.3-4a/11 OR A.4.3-4a/13)) THEN R ELSE N/A |
C249 IF (A.4.5-8/9 AND (A.4.3-4a/10 OR A.4.3-4a/11 OR A.4.3-4a/13 OR A.4.3-4a/14)) THEN R ELSE N/A |
C250 IF (A.4.5-8/12 AND (A.4.3-4a/11 OR A.4.3-4a/13 OR A.4.3-4a/14)) THEN R ELSE N/A |
C251 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/1 AND A.4.5-1/15 AND A.4.5-1/18 AND (A.4.5-1/37 OR A.4.5-1/38) AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C252 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/1 AND A.4.5-1/14 AND A.4.5-1/18 AND (A.4.5-1/37 OR A.4.5-1/38) AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C253 IF ((A.4.1-1/1) AND (A.4.6.1-1/1 OR A.4.6.1-1/2 OR A.4.6.3-1/1) AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12) AND A.4.5-1/39) THEN R ELSE N/A |
C254 IF ((A.4.1-1/1) AND (A.4.6.2-1/1) AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12) AND A.4.5-1/39) THEN R ELSE N/A |
C255 IF (A.4.1-1/1 AND (A.4.6.1-1/3 OR A.4.6.3-1/3 OR A.4.6.3-1/4) AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12) AND A.4.5-1/39) THEN R ELSE N/A |
C256 IF (A.4.1-1/1 AND (A.4.6.3-1/2 OR A.4.6.2-1/2) AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12) AND A.4.5-1/39) THEN R ELSE N/A |
C257 IF (A.4.1-1/1 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12) AND (A.4.6.3-1/6 OR A.4.6.3-1/7 OR A.4.6.3-1/9 OR OR A.4.6.3-1/10 OR A.4.6.3-1/11 OR A.4.6.3-1/12) AND A.4.5-1/39) THEN R ELSE N/A |
C258 IF (A.4.1-1/1 AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12) AND (A.4.6.3-1/8 OR A.4.6.3-1/13 OR A.4.6.3-1/14 OR A.4.6.3-1/15 OR A.4.6.3-1/16 OR A.4.6.3-1/17 OR A.4.6.3-1/18) AND A.4.5-1/39) THEN R ELSE N/A |
C259 IF (A.4.1-1/1 AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12) AND (A.4.6.3-1/14) AND A.4.5-1/39) THEN R ELSE N/A |
C260 IF (A.4.1-1/1 AND A.4.5-1/18 AND A.4.4-3a/103) THEN R ELSE N/A |
C260m IF (A.4.1-1/1 AND A.4.5-1/18 AND ((A.4.4-3a/103 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C261 IF (A.4.1-1/2 AND A.4.5-1/18 AND A.4.4-3b/103) THEN R ELSE N/A |
C261m IF (A.4.1-1/2 AND A.4.5-1/18 AND ((A.4.4-3b/103 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C262 IF (NOT(A.4.3-4a/1) AND A.4.1-1/1 AND A.4.3-7/4 AND A.4.4-3a/103) THEN R ELSE N/A |
C262m IF (NOT(A.4.3-4a/1) AND A.4.1-1/1 AND A.4.3-7/4 AND ((A.4.4-3a/103 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C263 IF (NOT(A.4.3-4a/1) AND A.4.1-1/2 AND A.4.3-7/4 AND A.4.4-3b/103) THEN R ELSE N/A |
C263m IF (NOT(A.4.3-4a/1) AND A.4.1-1/2 AND A.4.3-7/4 AND ((A.4.4-3b/103 AND NOT(A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/9))) THEN R ELSE N/A |
C264 IF A.4.1-1/1 AND A.4.5-1/15 AND A.4.5-1/32 AND A.4.5-1/56 THEN R ELSE N/A |
C265 IF A.4.1-1/2 AND A.4.5-1/14 AND A.4.5-1/32 AND A.4.5-1/56 THEN R ELSE N/A |
C266 IF (A.4.1-1/1 AND A.4.2-1/2 AND NOT A.4.5-1/18) AND (A.4.3-4/11 OR A.4.3-4/12) AND (A.4.6.1-1/5 OR A.4.6.3-1/8 OR A.4.6.3-1/13 OR A.4.6.3-1/14 OR A.4.6.3-1/15 OR A.4.6.3-1/16 OR A.4.6.3-1/17 OR A.4.6.3-1/18) THEN R ELSE N/A |
C267 IF A.4.1-1/1 AND A.4.2-1/2 AND (NOT A.4.5-1/18) AND (A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/10) AND (A.4.6.1-1/5 OR A.4.6.2-1/6 OR A.4.6.2-1/7 OR A.4.6.2-1/8 OR A.4.6.3-1/8 OR A.4.6.3-1/13 OR A.4.6.3-1/14 OR A.4.6.3-1/15 OR A.4.6.3-1/16 OR A.4.6.3-1/17 OR A.4.6.3-1/18) THEN R ELSE N/A |
C267h IF A.4.1-1/1 AND A.4.2-1/2 AND (A.4.3-4a/10 OR A.4.3-4a/11) AND A.4.6-1/4 AND (A.4.6.1-1/5 OR A.4.6.2-1/6 OR A.4.6.2-1/7 OR A.4.6.2-1/8 OR A.4.6.3-1/8 OR A.4.6.3-1/13 OR A.4.6.3-1/14 OR A.4.6.3-1/15 OR A.4.6.3-1/16 OR A.4.6.3-1/17 OR A.4.6.3-1/18) AND A.4.5-1/18 THEN R ELSE N/A |
C268 IF (NOT(A.4.3-4a/1) AND (A.4.1-1/1 AND A.4.1-1/2) AND (A.4.6.3-1/2 OR A.4.6.3-1/3 OR A.4.6.3-1/4) AND A.4.5-1/32) THEN R ELSE N/A |
C269 IF (NOT(A.4.3-4a/1) AND A.4.1-1/2 AND (A.4.6.3-1/2 OR A.4.6.3-1/3 OR A.4.6.3-1/4) AND A.4.5-1/32) THEN R ELSE N/A |
C270 IF (A.4.1-1/2 AND (A.4.6.1-1/4 OR A.4.6.3-1/6 OR A.4.6.3-1/7 OR A.4.6.3-1/9) AND (A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C271 IF (A.4.1-1/2 AND (A.4.6.3-1/10 OR A.4.6.2-1/4 OR A.4.6.2-1/5) AND (A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C272 IF (A.4.1-1/2 AND (A.4.6.1-1/5 OR A.4.6.3-1/14 OR A.4.6.3-1/15 OR A.4.6.3-1/16) AND (A.4.3-4/8 AND (A.4.3-4/11 OR A.4.3-4/12))) THEN R ELSE N/A |
C273 IF (A.4.1-1/2 AND (A.4.6.3-1/17 OR A.4.6.2-1/6 OR A.4.6.2-1/7 OR A.4.6.2-1/8) AND (A.4.3-4/8 AND (A.4.3-4/11 OR A.4.3-4/12))) THEN R ELSE N/A |
C274 IF A.4.1-1/2 AND A.4.5-1/54 THEN R ELSE N/A |
C275 IF A.4.1-1/2 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) AND A.4.5-1/54 AND A.4.5-1/55 THEN R ELSE N/A |
C276 IF A.4.1-1/2 AND A.4.5-1/55 THEN R ELSE N/A |
C277 IF A.4.1-1/2 AND A.4.5-1/8 AND A.4.5-1/55 THEN R ELSE N/A |
C278 IF (A.4.1-1/1 AND (A.4.6.1-1/1 OR A.4.6.1-1/2 OR A.4.6.3-1/1) AND A.4.5-1/18 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C279 IF (A.4.1-1/1 AND A.4.6.2-1/1 AND A.4.5-1/18 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C280 IF (A.4.1-1/1 AND A.4.6-1/1 AND A.4.5-1/37 AND A.4.5-1/46 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C281 IF (A.4.1-1/1 AND A.4.6-1/1 AND A.4.5-1/37 AND A.4.3-7/1 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C282 IF (A.4.1-1/1 AND A.4.6-1/1 AND A.4.5-1/37 AND A.4.3-7/1 AND A.4.4-3a/103 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C282m IF (A.4.1-1/1 AND A.4.6-1/1 AND A.4.5-1/37 AND A.4.3-7/1 AND ((A.4.4-3a/103 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12))) THEN R ELSE N/A |
C283 IF (A.4.1-1/2 AND A.4.6-1/1 AND A.4.5-1/38 AND A.4.3-7/1 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C284 IF (A.4.1-1/2 AND A.4.6-1/1 AND A.4.5-1/38 AND A.4.3-7/1 AND A.4.4-3b/103 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C284m IF (A.4.1-1/2 AND A.4.6-1/1 AND A.4.5-1/38 AND A.4.3-7/1 AND ((A.4.4-3b/103 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12))) THEN R ELSE N/A |
C285 IF ((A.4.1-1/1) AND (A.4.3-7/6)) THEN R ELSE N/A |
C286 IF ((A.4.1-1/1) AND (A.4.3-7/7)) THEN R ELSE N/A |
C287 IF ((A.4.1-1/2) AND (A.4.3-7/6)) THEN R ELSE N/A |
C288 IF ((A.4.1-1/2) AND (A.4.3-7/7)) THEN R ELSE N/A |
C289 IF ((A.4.1-1/1) AND (A.4.3-7/6) AND (A.4.2-1/6)) THEN R ELSE N/A |
C290 IF ((A.4.1-1/2) AND (A.4.3-7/6) AND (A.4.2-1/6)) THEN R ELSE N/A |
C291 IF ((A.4.1-1/2) AND (A.4.6.1-1/1 OR A.4.6.1-1/2 OR A.4.6.3-1/1) AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12) AND A.4.5-1/39) THEN R ELSE N/A |
C292 IF ((A.4.1-1/2) AND (A.4.6.2-1/1) AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12) AND A.4.5-1/39) THEN R ELSE N/A |
C293 IF (A.4.1-1/2 AND (A.4.6.1-1/3 OR A.4.6.3-1/3 OR A.4.6.3-1/4) AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12) AND A.4.5-1/39) THEN R ELSE N/A |
C294 IF (A.4.1-1/2 AND (A.4.6.3-1/2 OR A.4.6.2-1/2) AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12) AND A.4.5-1/39) THEN R ELSE N/A |
C295 IF (A.4.1-1/2 AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12) AND (A.4.6.3-1/6 OR A.4.6.3-1/7 OR A.4.6.3-1/12 OR A.4.6.2-1/3 OR A.4.6.3-1/11) AND A.4.5-1/39) THEN R ELSE N/A |
C296 IF (A.4.1-1/2 AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12) AND (A.4.6.3-1/8 OR A.4.6.3-1/13 OR A.4.6.3-1/14 OR A.4.6.3-1/15 OR A.4.6.3-1/16 OR A.4.6.3-1/17 OR A.4.6.3-1/18 AND A.4.5-1/39) THEN R ELSE N/A |
C297 IF (A.4.1-1/2 AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12) AND (A.4.6.3-1/14) AND A.4.5-1/39) THEN R ELSE N/A |
C298 IF A.4.1-1/8 AND A.4.3-4c/2 THEN R ELSE N/A |
C299 IF (A.4.1-1/1 AND A.4.3-7/5) THEN R ELSE N/A |
C300 IF (A.4.1-1/2 AND A.4.3-7/5) THEN R ELSE N/A |
C301 IF ((A.4.1-1/1 OR A.4.1-1/2) AND A.4.5-1/58) THEN R ELSE N/A |
C302 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.1-1/2 AND A.4.6.1-2/2 AND A.4.5-1/58) THEN R ELSE N/A |
C303 IF (NOT(A.4.3-4a/1 OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.3-1/1 AND A.4.6.3-2/1 AND A.4.5-1/58) THEN R ELSE N/A |
C304 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.2-1/1 AND A.4.6.2-2/1 AND A.4.5-1/58) THEN R ELSE N/A |
C305 IF ((A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.3-1/1 AND A.4.6.3-2/1 AND A.4.5-1/62) THEN R ELSE N/A |
C306 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/1 AND A.4.5-1/14 AND (A.4.5-1/37 OR A.4.5-1/38) AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C307 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/2 AND A.4.5-1/14 AND (A.4.5-1/37 OR A.4.5-1/38) AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C308 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/3 AND A.4.5-1/14 AND (A.4.5-1/37 OR A.4.5-1/38) AND (A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C309 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/4 AND A.4.5-1/14 AND (A.4.5-1/37 OR A.4.5-1/38) AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C310 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/1 AND A.4.5-1/15 AND (A.4.5-1/37 OR A.4.5-1/38) AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C311 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/2 AND A.4.5-1/15 AND (A.4.5-1/37 OR A.4.5-1/38) AND (A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C312 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/3 AND A.4.5-1/15 AND (A.4.5-1/37 OR A.4.5-1/38) AND (A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C313 IF (A.4.1-1/10 AND A.4.3-4d/2 AND A.4.5-7/1) THEN R ELSE N/A |
C314 IF A.4.1-1/1 AND (A.4.3-4aa/2 OR A.4.5-1/25) THEN R ELSE N/A |
C315 IF A.4.1-1/1 AND (A.4.3-4aa/2 AND A.4.5-1/26 THEN R ELSE N/A |
C316 IF A.4.1-1/2 AND (A.4.3-4aa/2 OR A.4.5-1/25) THEN R ELSE N/A |
C316a IF A.4.1-1/2 AND A.4.3-4aa/2 AND A.4.5-1/25 THEN R ELSE N/A |
C316b IF A.4.1-1/2 AND A.4.3-4aa/2 AND A.4.5-1/26 THEN R ELSE N/A |
C317 IF A.4.1-1/2 AND (A.4.3-4aa/2 AND A.4.5-1/26 THEN R ELSE N/A |
C318 IF ((A.4.1-1/1 OR A.4.1-1/2) AND A.4.5-1/13 AND A.4.5-1/58) THEN R ELSE N/A |
C319 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.1-1/2 AND A.4.6.1-2/2 AND NOT(A.4.5-1/17)) THEN R ELSE N/A |
C320 IF ((A.4.1-1/1 OR A.4.1-1/2) AND A.4.1-1/10 AND A.4.5-1/66 AND A.4.5-1/67) THEN R ELSE N/A |
C321 IF (A.4.1-1/10 AND A.4.3-4d/2 AND A.4.5-7/1 AND A.4.5-1/70) THEN R ELSE N/A |
C322 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/4 AND A.4.5-1/15 AND (A.4.5-1/37 OR A.4.5-1/38) AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C323 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 AND A.4.4-3a/103 AND A.4.3-7/8) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C323m IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 AND A.4.3-7/8) AND ((A.4.4-3a/103 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12))) THEN R ELSE N/A |
C324 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/2 AND A.4.4-3b/103 AND A.4.3-7/8) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C324m IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/2 AND A.4.3-7/8) AND ((A.4.4-3b/103 AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/9 OR A.4.3-4/10)) OR (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12))) THEN R ELSE N/A |
C325 IF (A.4.1-1/8 OR A.4.1-1/8a) AND A.4.3-3b/5 THEN R ELSE N/A |
C326 IF (NOT(A.4.3-4a/1 OR A.4.3-4aa/1 OR A.4.5-1/58) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.1-1/2 AND A.4.6.1-2/2 AND A.4.5-1/17) THEN R ELSE N/A |
C327 IF (NOT(A.4.3-4a/1 OR A.4.3-4aa/1 OR A.4.5-1/58) AND (A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.3-1/1 AND A.4.6.3-2/1 AND A.4.5-1/17) THEN R ELSE N/A |
C328 IF A.4.1-1/1 AND A.4.5-1/15 AND A.4.5-1/32 AND A.4.5-8/1 THEN R ELSE N/A |
C329 IF A.4.1-1/2 AND A.4.5-1/14 AND A.4.5-1/32 AND A.4.5-8/2 THEN R ELSE N/A |
C330 IF (A.4.1-1/1 AND A.4.2-1/2 AND NOT A.4.5-1/18) AND (A.4.3-4/11 OR A.4.3-4/12) AND (A.4.6.3-1/19 OR A.4.6.3-1/20 OR A.4.6.3-1/21 OR A.4.6.3-1/22 OR A.4.6.3-1/23) THEN R ELSE N/A |
C331 IF A.4.1-1/1 AND A.4.2-1/2 AND (NOT A.4.5-1/18) AND (A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/10) AND (A.4.6.3-1/19 OR A.4.6.3-1/20 OR A.4.6.3-1/21 OR A.4.6.3-1/22 OR A.4.6.3-1/23) THEN R ELSE N/A |
C331a IF A.4.1-1/2 AND A.4.2-1/2 AND (NOT A.4.5-1/18) AND (A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/10) AND (A.4.6.3-1/19 OR A.4.6.3-1/20 OR A.4.6.3-1/21 OR A.4.6.3-1/22 OR A.4.6.3-1/23) THEN R ELSE N/A |
C331h IF A.4.1-1/1 AND A.4.2-1/2 AND A.4.3-4a/11 AND A.4.6-1/4 AND (A.4.6.3-1/19 OR A.4.6.3-1/20 OR A.4.6.3-1/21 OR A.4.6.3-1/22 OR A.4.6.3-1/23) AND A.4.5-1/18 THEN R ELSE N/A |
C331ha IF A.4.1-1/2 AND A.4.2-1/2 AND A.4.3-4a/11 AND (A.4.6.3-1/19 OR A.4.6.3-1/20 OR A.4.6.3-1/21 OR A.4.6.3-1/22 OR A.4.6.3-1/23) AND A.4.5-1/18 THEN R ELSE N/A |
C332 IF A.4.1-1/2 AND A.4.2-1/2 AND A.4.3-4a/11 AND A.4.6-1/4 AND (A.4.6.1-1/5 OR A.4.6.2-1/6 OR A.4.6.2-1/7 OR A.4.6.2-1/8 OR A.4.6.3-1/8 OR A.4.6.3-1/13 OR A.4.6.3-1/14 OR A.4.6.3-1/15 OR A.4.6.3-1/16 OR A.4.6.3-1/17 OR A.4.6.3-1/18) AND A.4.5-1/18 THEN R ELSE N/A |
C333 IF (A.4.1-1/10 AND A.4.3-4d/2 AND A.4.5-7b) THEN R ELSE N/A |
C334 IF ((A.4.1-1/1 OR A.4.1-1/2) AND A.4.6-1/3 AND A.4.6-2/3) THEN R ELSE N/A |
C335 IF (A.4.1-1/10 AND A.4.3-4d/2 AND A.4.5-7/1 AND A.4.3-3b/4) THEN R ELSE N/A |
C336 IF ((A.4.1-1/1 OR A.4.1-1/2) AND A.4.6.3-1/6 AND A.4.6-2/3) THEN R ELSE N/A |
C337 IF ((A.4.1-1/1) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12 ) AND A.4.4-3a/103 AND A.4.5-1/82) THEN R ELSE N/A |
C338 IF ((A.4.1-1/2) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12 ) AND A.4.4-3a/103 AND A.4.5-1/83) THEN R ELSE N/A |
C339 IF (NOT((A.4.3-4a/1) or (A.4.3-4/1)) AND A.4.1-1/1 AND ( A.4.5-1/8 or A.5.-1/11 or A.4.5-1/12) AND A.4.5-1/83 ) THEN R ELSE N/A |
C340 IF (NOT((A.4.3-4a/1) or (A.4.3-4/1)) AND A.4.1-1/2 AND ( A.4.5-1/8 or A.5.-1/11 or A.4.5-1/12) AND A.4.5-1/83 ) THEN R ELSE N/A |
C341 IF ((A.4.1-1/2) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12 )) THEN R ELSE N/A |
C342 IF( (A.4.1-1/1 AND A.4.2-1/2) AND (A.4.6.3-1/19 OR A.4.6.3-1/20 OR A.4.6.3-1/21 OR A.4.6.3-1/22 OR A.4.6.3-1/23)) OR ( (A.4.1-1/2 AND A.4.2-1/2) AND (A.4.6.3-1/19 OR A.4.6.3-1/20 OR A.4.6.3-1/21 OR A.4.6.3-1/22 OR A.4.6.3-1/23)) OR ( (A.4.1-1/1 AND A.4.1-1/2 AND A.4.2-1/7) AND (A.4.6.3-1/19 OR A.4.6.3-1/20 OR A.4.6.3-1/21 OR A.4.6.3-1/22 OR A.4.6.3-1/23)) THEN R ELSE N/A |
C342h IF( (A.4.1-1/1 AND A.4.2-1/2) AND (A.4.6.3-1/19 OR A.4.6.3-1/20 OR A.4.6.3-1/21 OR A.4.6.3-1/22 OR A.4.6.3-1/23)) OR ( (A.4.1-1/2 AND A.4.2-1/2) AND (A.4.6.3-1/19 OR A.4.6.3-1/20 OR A.4.6.3-1/21 OR A.4.6.3-1/22 OR A.4.6.3-1/23)) OR ( (A.4.1-1/1 AND A.4.1-1/2 AND A.4.2-1/7) AND (A.4.6.3-1/19 OR A.4.6.3-1/20 OR A.4.6.3-1/21 OR A.4.6.3-1/22 OR A.4.6.3-1/23)) AND A.4.5-1/18 THEN R ELSE N/A |
C343 IF A.4.1-1/1 AND A.4.2-1/2 AND (NOT A.4.5-1/18) AND (A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/10) AND A.4.6-1/6 THEN R ELSE N/A |
C344 IF A.4.1-1/1 AND A.4.2-1/2 AND A.4.5-1/18 AND A.4.3-4a/11 AND A.4.6-1/6 THEN R ELSE N/A |
C345 IF A.4.1-1/2 AND A.4.2-1/2 AND (NOT A.4.5-1/18) AND (A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/10) AND A.4.6-1/6 THEN R ELSE N/A |
C346 IF A.4.1-1/2 AND A.4.2-1/2 AND A.4.5-1/18 AND A.4.3-4a/11 AND A.4.6-1/6 THEN R ELSE N/A |
C347 IF A.4.1-1/8 AND (A.4.3-4c/1 or A.4.3-4c/2) THEN R ELSE N/A |
C348 Void |
C349 IF (A.4.1-1/1 AND A.4.6-1/5 AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C350 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/5 AND A.4.5-1/15 AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C351 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/5 AND A.4.5-1/14 AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C352 IF A.4.3-3b/2 AND NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.5-1/94 AND (A.4.5-1/95 OR A.4.5-1/96 OR A.4.5-1/97) AND A.4.1-1/1THEN R ELSE N/A |
C352a IF A.4.3-3b/2 AND NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.5-1/94 AND A.4.5-1/95 AND A.4.1-1/2 THEN R ELSE N/A |
C353 IF A.4.1-1/1 AND NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.5-1/94 AND (A.4.5-1/95 OR A.4.5-1/96 OR A.4.5-1/97) THEN R ELSE N/A |
C353a IF A.4.1-1/2 AND NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.5-1/94 AND A.4.5-1/95 THEN R ELSE N/A |
C354 IF ((A.4.1-1/1) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12 ) AND A.4.5-1/94 AND (A.4.5-1/95 OR A.4.5-1/96 OR A.4.5-1/97)) THEN R ELSE N/A |
C354a IF ((A.4.1-1/2) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12 ) AND A.4.5-1/88 AND A.4.5-1/89) THEN R ELSE N/A |
C355 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1) AND A.4.4-3a/103 AND A.4.5-1/88 AND (A.4.5-1/89 OR A.4.5-1/90 OR A.4.5-1/91)) THEN R ELSE N/A |
C355a IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/2) AND A.4.4-3a/103 AND A.4.5-1/88 AND A.4.5-1/89) THEN R ELSE N/A |
C356 IF NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND A.4.1-1/2 AND A.4.5-1/88 AND A.4.5-1/89 THEN R ELSE N/A |
C357 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1 AND A.4.4-3a/103) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12 ) AND A.4.5-1/88 AND (A.4.5-1/89 OR A.4.5-1/90 OR A.4.5-1/91)) THEN R ELSE N/A |
C357a IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/2 AND A.4.4-3a/103) AND (A.4.3-4/2 OR A.4.3-4/3 OR A.4.3-4/4 OR A.4.3-4/5 OR A.4.3-4/6 OR A.4.3-4/7 OR A.4.3-4/8 OR A.4.3-4/9 OR A.4.3-4/10 OR A.4.3-4/11 OR A.4.3-4/12 ) AND A.4.5-1/88 AND A.4.5-1/89) THEN R ELSE N/A |
C358 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/6 AND A.4.5-1/15 AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C359 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/6 AND A.4.5-1/14 AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C360 IF A.4.1-1/2 AND A.4.2-1/2 AND (NOT A.4.5-1/18) AND (A.4.3-4/11 OR A.4.3-4/12 OR A.4.3-4a/6 OR A.4.3-4a/7 OR A.4.3-4a/10) AND (A.4.6.3-1/13 OR A.4.6.3-1/14 OR A.4.6.3-1/15 OR A.4.6.3-1/16 OR A.4.6.3-1/17 OR A.4.6.3-1/18) THEN R ELSE N/A |
C361 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/1) AND A.4.4-3a/103) AND A.4.3-7/9 THEN R ELSE N/A |
C362 IF (NOT(A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4aa/1) AND (A.4.1-1/2 AND A.4.4-3b/104) AND A.4.3-7/9) THEN R ELSE N/A |
C363 IF (A.4.1-1/1 AND A.4.2-1/2 AND A.4.6-1/5 AND (NOT A.4.5-1/18) AND (A.4.6.3-1/20 OR A.4.6.3-1/21 OR A.4.6.3-1/22 OR A.4.6.3-1/23 OR A.4.6.3-1/24) AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C364 IF (A.4.1-1/1 AND A.4.2-1/2 AND A.4.6-1/6 AND (NOT A.4.5-1/18) AND A.4.6.3-1/20 AND (A.4.3-4/8 OR A.4.3-4/11 OR A.4.3-4/12)) THEN R ELSE N/A |
C365 IF (A.4.1-1/2 AND A.4.6-1/5 AND ((A.4.6.3-1/19) OR (A.4.6.3-1/20)) AND (A.4.3-4/8 AND (A.4.3-4/11 OR A.4.3-4/12))) THEN R ELSE N/A |
C366 IF (A.4.1-1/2 AND A.4.6-1/6 AND (A.4.6.3-1/19) AND (A.4.3-4/8 AND (A.4.3-4/11 OR A.4.3-4/12))) THEN R ELSE N/A |
C367 IF (A.4.1-1/1 AND A.4.5-1/18 AND (A.4.3-4/11 OR A.4.3-4/12) AND NOT (A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4a/2 OR A.4.3-4a/3 OR A.4.3-4a/4 OR A.4.3-4a/5 OR A.4.3-4a/15)) THEN R ELSE N/A |
C368 IF (A.4.1-1/2 AND A.4.5-1/18 AND (A.4.3-4/11 OR A.4.3-4/12) AND NOT (A.4.3-4a/1 OR A.4.3-4a/1a OR A.4.3-4a/2 OR A.4.3-4a/3 OR A.4.3-4a/4 OR A.4.3-4a/5 OR A.4.3-4a/15)) THEN R ELSE N/A |
C369 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/6 AND A.4.5-1/15 AND (NOT A.4.5-1/18) AND A.4.3-4a/10 AND (A.4.6.3-1/26 OR A.4.6.3-1/27)) THEN R ELSE N/A |
C370 IF ((A.4.1-1/1 AND A.4.1-1/2) AND A.4.6-1/6 AND A.4.5-1/14 AND (NOT A.4.5-1/18) AND A.4.3-4a/10 AND (A.4.6.3-1/26 OR A.4.6.3-1/27)) THEN R ELSE N/A |
Note 1: Cxxxh applicability is defined for small cell enhancements for physical layer related test. |
Table 4.1-1b: Tested Bands Selection Criteria
Code |
Selection |
Comment |
D01 |
A.4.3-3 |
All supported Bands |
D02 |
A.4.3-3 AND FDD |
All supported FDD Bands |
D03 |
A.4.3-3 AND TDD |
All supported TDD Bands |
D04 |
A.4.3-3 AND {14, 31, 41, 72} |
Band 14, 31, 41 or 72 if supported |
D05 |
A.4.3-3 AND A.4.5-3 |
Bands supporting UL MIMO |
D06 |
A.4.3-3 AND NOT A.4.5-3 |
Bands not supporting UL MIMO |
D07 |
A.4.3-3 AND A.4.5-4 |
Bands supporting Multicluster PUSCH |
D08 |
A.4.3-3 AND NOT FALLBACK(A.4.6.1-3) |
All supported Bands that are not part of contiguous CA configuration. |
D09 |
A.4.3-3 AND A.4.5-5 |
Bands supporting 4 Rx antenna ports |
D10 |
A.4.3-3 AND A.4.5-6a |
Bands supporting ProSe Direct |
D11 |
A.4.3-3 AND category NB1 and NB2 |
All supported category NB1 and NB2 Bands |
D12 |
A.4.3-3 AND { category NB1 and NB2 Bands < 1GHz} |
Lowest and highest category NB1 and NB2 Bands supported below 1GHz (Note 2) |
D13 |
A.4.3-3 AND { category NB1 and NB2 Bands > 1GHz} |
Lowest and highest category NB1 and NB2 Bands supported above 1GHz (Note 3) |
D14 |
A.4.3-3 AND A.4.5-7 |
Bands supporting V2X Sidelink Communication |
D15 |
A.4.3-3 AND NOT A.4.5-5 |
Bands not supporting 4Rx antenna ports |
D16 |
A.4.3-3c |
All supported Power Class 1 Bands |
D17 |
A.4.3-3d |
All supported Power Class 2 Bands |
D17a |
A.4.3-3c OR A.4.3-3d |
All supported Power Class 1 Bands or Power Class 2 Bands |
D18 |
A.4.3-3 AND { category NB1 and NB2 TDD Bands > 1GHz} |
Category NB1 and NB2 TDD Bands supported above 1GHz (Note 4) |
Note 1: Band Selection is based on set theory. For each feature, item number shall correspond to the Band number. The result is the set of bands for which the test shall be conducted. The following operators are used: AND: Set intersection ( ). {1,2} AND {2,3} = {2} OR: Set union ( ). {1,2} OR {2,3} = {1,2,3} NOT: Set complement (\), full set being all bands. NOT{1} = {2 …256} Also note that this is set without repetitions so {1} AND {1} = {1} The following basic sets are used: FDD: All FDD bands, currently {1…32, 65…70} TDD: All TDD bands, currently {33…64} Category NB1: All Category NB1 bands, currently {1, 2, 3, 5, 8, 11, 12, 13, 17, 18, 19, 20, 21, 25,, 26, 28, 31, 66, 70} {1,2}: Explicitly given band set The following sets derived from pro-forma tables are also used: A.4.X-Y: All bands supporting the feature defined in A.4.X-Y. For A.4.3-3, all supported bands. FALLBACK(A.4.6.X-Y): Fallback bands of supported CA Combinations defined in Table A.4.6.X-Y Note 2: Category NB1 Bands < 1GHz {5, 8, 12, 13, 17, 18, 19, 20, 26, 28, 31} Note 3: Category NB1 Bands > 1GHz {1, 2, 3, 11, 21, 25, 66, 70} Note 4: Category NB1 and NB2 Bands > 1GHz {41} |
Table 4.1-1c: Tested CA Configurations Selection Criteria
Code |
Selection |
Comment |
E01 |
UL(A.4.6.1-3) AND CARRIER_NO(2) |
All supported intra-band contiguous CA Configurations with 2 carriers in both UL and DL |
E02 |
UL(A.4.6.2-3) AND CARRIER_NO(2) |
All supported intra-band non-contiguous CA Configurations with 2 carriers in both UL and DL |
E03 |
UL(A.4.6.3-3) AND CARRIER_NO(2) |
All supported inter-band CA Configurations with 2 carriers in both UL and DL |
E04 |
A.4.6.1-3 AND CARRIER_NO(2) AND NOT UL(A.4.6.1-3) |
All supported intra-band contiguous CA Configurations with 2 carriers in DL but no CA in UL |
E05 |
A.4.6.2-3 AND CARRIER_NO(2) AND NOT UL(A.4.6.2-3) |
All supported intra-band non-contiguous CA Configurations with 2 carriers in DL but no CA in UL |
E06 |
A.4.6.3-3 AND CARRIER_NO(2) AND NOT UL(A.4.6.3-3) |
All supported inter-band CA Configurations with 2 carriers in DL but no CA in UL |
E07 |
((A.4.6.1-3 AND NOT UL(A.4.6.1-3)) OR (A.4.6.2-3 AND NOT UL(A.4.6.2-3)) OR (A.4.6.3-3 AND NOT UL(A.4.6.3-3)) OR (A.4.6.3-4 AND NOT UL(A.4.6.3-4)) OR (A.4.6.3-5 AND NOT UL(A.4.6.3-5))) AND CARRIER_NO(3) |
All supported 3DL CA without UL |
E08 |
E04 AND NOT DL_FALLBACKS |
All supported intra-band contiguous CA Configurations with 2 carriers in DL but no CA in UL, that are not fallbacks of 3DL CA |
E09 |
E05 AND NOT DL_FALLBACKS |
All supported intra-band non-contiguous CA Configurations with 2 carriers in DL but no CA in UL that are not fallbacks of 3DL CA. |
E10 |
E06 AND NOT DL_FALLBACKS |
All supported inter-band CA Configurations with 2 carriers in DL but no CA in UL that are not fallbacks of 3DL CA |
E11 |
E04 AND NOT (FALLBACK(A.4.6.2-3) OR FALLBACK(A.4.6.3-3) OR FALLBACK(A.4.6.3-4) OR FALLBACK(A.4.6.3-5)) |
All supported intra-band contiguous CA Configurations with 2 carriers in DL but no CA in UL, that are not fallbacks of 3DL CA, except of class D intra-band 3DL CA. |
E12 |
E06 AND NOT (FALLBACK(A.4.6. 1-3) OR FALLBACK(A.4.6.3-4) OR FALLBACK(A.4.6.3-5)) |
All supported inter-band CA Configurations with 2 carriers in DL that are fallbacks of inter-band on inter-band + intra-band contiguous 3DL CA. |
DL_FALLBACKS |
FALLBACK(A.4.6.1-3) OR FALLBACK(A.4.6.2-3) OR FALLBACK(A.4.6.3-3) OR FALLBACK(A.4.6.3-4) OR FALLBACK(A.4.6.3-5) |
All DL Fallbacks of supported CA Configurations |
DL_FALLBACKS_EtoD |
FALLBACK_EtoD(A.4.6.1-3) OR FALLBACK_EtoD(A.4.6.2-3) OR FALLBACK_EtoD(A.4.6.3-3) OR FALLBACK_EtoD(A.4.6.3-4) OR FALLBACK_EtoD(A.4.6.3-5) |
All DL Fallbacks of supported CA Configurations where BW class for one sub-block has changed from class E to class D |
DL_FALLBACKS_BtoA |
FALLBACK_BtoA(A.4.6.1-3) OR FALLBACK_BtoA(A.4.6.2-3) OR FALLBACK_BtoA(A.4.6.3-3) OR FALLBACK_BtoA(A.4.6.3-4) OR FALLBACK_BtoA(A.4.6.3-5) |
All DL Fallbacks of supported CA Configurations where BW class for one sub-block has changed from class B to class A |
DL_FALLBACKS_LAA |
FALLBACK_LAA(A.4.6.1-3) OR FALLBACK_LAA(A.4.6.2-3) OR FALLBACK_LAA(A.4.6.3-3) OR FALLBACK_LAA(A.4.6.3-4) OR FALLBACK_LAA(A.4.6.3-5) |
All DL Fallbacks of supported CA Configurations where BW class for sub-block in LAA band has changed |
E13 |
E06 AND DL_ONLY_BAND |
All supported inter-band CA Configurations with 2 carriers in DL where one of the bands is a DL-only band |
E14 |
((A.4.6.1-3 AND NOT UL(A.4.6.1-3)) OR (A.4.6.2-3 AND NOT UL(A.4.6.2-3)) OR (A.4.6.3-3 AND NOT UL(A.4.6.3-3)) OR (A.4.6.3-4 AND NOT UL(A.4.6.3-4)) OR (A.4.6.3-5 AND NOT UL(A.4.6.3-5))) AND CARRIER_NO(4) |
All supported 4DL CA without UL |
E15 |
((A.4.6.1-3 AND NOT UL(A.4.6.1-3)) OR (A.4.6.2-3 AND NOT UL(A.4.6.2-3)) OR (A.4.6.3-3 AND NOT UL(A.4.6.3-3)) OR (A.4.6.3-4 AND NOT UL(A.4.6.3-4)) OR (A.4.6.3-5 AND NOT UL(A.4.6.3-5))) AND CARRIER_NO(5) |
All supported 5DL CA without UL |
E16 |
A.4.5-7a |
Bands supporting Inter-band con-current V2X configurations |
E17 |
A.4.5-7b |
Bands supporting V2X Intra-band multi-carrier configurations |
E18 |
UL(A.4.6.1-3 OR A.4.6.2-3 OR A.4.6.3-3 OR A.4.6.3-4) AND CARRIER_NO(3) |
All support 3DL CA with UL CA |
E19 |
E07 AND NOT DL_FALLBACKS OR E18 {AND DL_FALLBACKS} |
All support 3DL CA without UL CA, that are not fallbacks of 4DL CA. OR All support 3DL CA with UL CA |
E20 |
UL({A.4.6.1-3 OR A.4.6.2-3} OR A.4.6.3-3 OR A.4.6.3-4 OR A.4.6.3-5) AND CARRIER_NO(4) |
All support 4DL CA with UL CA |
E21 |
E14 AND NOT DL_FALLBACKS OR E20 {AND DL_FALLBACKS} |
All support 4DL CA without UL CA, that are not fallbacks of 5DL CA. OR All support 4DL CA with UL CA |
E22 |
(E07 AND NOT DL_FALLBACKS) OR (E07 AND DL_FALLBACKS_EtoD) OR (E07 AND DL_FALLBACKS_BtoA) OR E18 |
All supported 3DL CA without UL CA, that are not fallbacks of 4DL CA except class E to D and class B to A fallback. OR All supported 3DL CA with UL CA |
E23 |
(E14 AND NOT DL_FALLBACKS) OR (E14 AND DL_FALLBACKS_EtoD) OR (E14 AND DL_FALLBACKS_BtoA) OR E20 |
All supported 4DL CA without UL CA, that are not fallbacks of 4DL CA except class E to D and class B to A fallback. OR All supported 4DL CA with UL CA |
E24 |
(E07 AND NOT DL_FALLBACKS_LAA) OR E18 |
All supported 3DL CA without UL CA, that are not LAA fallbacks of 4DL CA. OR All supported 3DL CA with UL CA |
E25 |
(E14 AND NOT DL_FALLBACKS_LAA) OR E20 |
All supported 4DL CA without UL CA, that are not LAA fallbacks of 5DL CA. OR All supported 4DL CA with UL CA |
E26 |
((A.4.6.1-3 AND NOT UL(A.4.6.1-3)) OR (A.4.6.2-3 AND NOT UL(A.4.6.2-3)) OR (A.4.6.3-3 AND NOT UL(A.4.6.3-3)) OR (A.4.6.3-4 AND NOT UL(A.4.6.3-4)) OR (A.4.6.3-5 AND NOT UL(A.4.6.3-5))) AND CARRIER_NO(6) |
All supported 6DL CA without UL |
Note: CA Configuration Selection is based on set theory. Each CA Configuration is designated by its name, including bands and BW classes, e.g. CA_1A-5A. The following operators are used: AND: Set intersection ( ). {CA_1C,CA_1A-5A} AND {CA_1C, CA_2A-4A } = CA_1C OR: Set union ( ). {CA_1C,CA_1A-5A} OR {CA_1C, CA_2A-4A } = {CA_1C,CA_1A-5A, CA_2A-4A} NOT: Set complement (\), full set being all possible CA Configurations Also note that this is set without repetitions so {CA_1C} AND {CA_1C} = {CA_1C} The following basic sets are used: FDD: All FDD-only CA Configurations TDD: All TDD-only CA Configurations FDD-TDD: All mixed CA Configurations {CA_1C}: Explicitly given CA Configurations CARRIER_NO(n): All CA Configurations with n Carriers, e.g. for n=2 CA_1C and CA_1A-5A would be a part of this set BAND_NO(n): All CA Configurations containing n Bands, e.g.. for n=2, CA_1A-5A and CA_1A-41C are part of this set BWCLASS(x): All CA Configurations containing BW Class x, e.g.. for x=C, CA_1C and CA_1A-41C are part of this set DL_ONLY_BAND: All CA configurations containing a DL-only band, e.g. CA_20A-32A is part of this set The following sets derived from pro-forma tables are also used: A.4.6.X-Y: All supported DL CA Combinations defined in table A.4.6.X-Y UL(A.4.6.X-Y): All DL CA Combinations that also support UL CA with any number of carriers >1, as per column "Supported CA Bandwidth Class(es) in UL" defined in table A.4.6.X-Y. UL_2CC(A.4.6.X-Y): All DL CA Combinations that also support 2 Carrier UL CA, as per column "Supported CA Bandwidth Class(es) in UL" defined in table A.4.6.X-Y. Note that DL might support a larger number of carriers than UL. UL_3CC(A.4.6.X-Y): All DL CA Combinations that also support 3 Carrier UL CA, as per column "Supported CA Bandwidth Class(es) in UL" defined in table A.4.6.X-Y FALLBACK(A.4.6.X-Y): Fallback DL CA Combinations of supported CA Combinations defined in Table A.4.6.X-Y FALLBACK_EtoD(A.4.6.X-Y): Fallback DL CA Combinations of supported CA Combinations defined in Table A.4.6.X-Y where BW class for one sub-block has changed from class E to class D FALLBACK_BtoA(A.4.6.X-Y): Fallback DL CA Combinations of supported CA Combinations defined in Table A.4.6.X-Y where BW class for one sub-block has changed from class B to class A FALLBACK_LAA(A.4.6.X-Y): Fallback DL CA Combinations of supported CA Combinations defined in Table A.4.6.X-Y where BW class for B46 or B49 band changed from class E to D, D to C or C to A FALLBACK_UL(A.4.6.X-Y): Fallback DL and UL CA Combinations of supported CA Combinations defined in Table A.4.6.X-Y. This set only includes Combinations with same CA Capability in UL and DL |
Table 4.1-2: Default Fallback Bands and Fallback CA Configurations
CA Configuration |
Default Fallback Bands |
Default Fallback CA Configurations (Note 3) |
CA_XC (2 carrier intra-band contiguous) |
X |
– |
CA_XB (2 carrier intra-band contiguous) |
X |
– |
CA_XA-YA (2 carrier inter-band) |
X,Y |
– |
CA_XA-XA (2 carrier intra-band non-contiguous) |
X |
– |
CA_XD (3 carrier intra-band contiguous) |
X |
CA_XC |
CA_XA-YA-ZA (3 carrier inter-band) |
X,Y,Z |
CA_XA-YA, CA_XA-ZA, CA_YA-ZA |
CA_XC-YA(3 carrier intra-band contiguous + inter-band)2 |
X,Y |
CA_XC, CA_XA-YA |
CA_XB-YA(3 carrier intra-band contiguous + inter-band)2 |
X,Y |
CA_XB, CA_XA-YA |
CA_XA-XA-YA(3 carrier intra-band non-contiguous + inter-band)2 |
X,Y |
CA_XA-YA, CA_XA-XA |
CA_XC-XA(3 carrier intra-band non-contiguous + intra-band contiguous)2 |
X |
CA_XC, CA_XA-XA |
CA_XE (4 carrier intra-band contiguous) |
X |
CA_XD |
CA_XA-XD (4 carrier intra-band contiguous + inter-band with 2 bands)2 |
X |
CA_XA-XC |
CA_XC-YC (4 carrier intra-band contiguous + inter-band with 2 bands)2 |
X, Y |
CA_XA-YC, CA_XC-YA |
CA_XA-XA-YC (4 carrier intra-band non-contiguous + intra-band contiguous + inter-band with 2 bands) |
X, Y |
CA_XA-XA-YA, CA_XA-YC |
CA_XA-YA-ZC (4 carrier intra-band contiguous + inter-band with 3 bands)2 |
X, Y, Z |
CA_XA-YA-ZA, CA_XA-ZC CA_ YA-ZC |
CA_XC-XC (4 carrier intra-band non-contiguous + intra-band contiguous) |
X |
CA_XC-XA, CA_XA-XC |
CA_XA-YA-YC (4 carrier intra-band non-contiguous + intra-band contiguous + inter-band with 2 bands) 2 |
X, Y |
CA_XA-YA-YA, CA_XA -YC, CA YA-YC |
CA_XA-XA-YA-YA (4 carrier intra-band non-contiguous + inter-band with 2 bands)2 |
X, Y |
CA_XA-XA-YA, CA_XA-YA-YA |
CA_XA-YA-ZA-RA (4 carrier inter-band with 4 bands) |
X, Y, Z, R |
CA_XA-YA-ZA, CA_XA-YA-RA, CA_XA-ZA-RA, CA_YA-ZA-RA |
CA_XF (5 carrier intra-band contiguous) |
X |
CA_XE |
CA_XA-XE (5 carrier intra-band non-contiguous + intra-band contiguous) |
X |
CA_XE, CA_XA-XD |
CA_XC-XD (5 carrier intra-band non-contiguous + intra-band contiguous) |
X |
CA_XC-XC, CA_XA-XD |
CA_XA-YE (5 carrier intra-band contiguous + inter-band with 2 bands)2 |
X, Y |
CA_XA-YD, CA_YE |
CA_XC-YD (5 carrier intra-band contiguous + inter-band with 2 bands)2 |
X, Y |
CA_XC-YC, CA_XA-YD |
CA_XA-YA-ZD (5 carrier intra-band contiguous + inter-band with 3 bands)2 |
X, Y, Z |
CA_XA-YA-ZC, CA_XA-ZD, CA_YA-ZD |
CA_XA-YC-ZC (5 carrier intra-band contiguous + inter-band with 3 bands)2 |
X, Y, Z |
CA_XA-YC-ZA, CA_XA-YA-ZC, CA_YC-ZC |
CA_XA-YA-ZA-RC (5 carrier intra-band contiguous + inter-band with 4 bands)2 |
X, Y, Z, R |
CA_XA-YA-ZA, CA_XA-YA-RC, CA_XA-ZA-RC, CA_YA-ZA-RC |
CA_XA-YA-YD (5 carrier intra-band non-contiguous + intra-band contiguous + inter-band with 2 bands) 2 |
X, Y |
CA_XA-YA-YC, CA_XA-YD, CA_YA-YD |
CA_XA-YC-YC (5 carrier intra-band non-contiguous + intra-band contiguous + inter-band with 2 bands) 2 |
X, Y |
CA_XA-YC-YA, CA_XA-YA-YC, CA_YC-YC |
CA_XA-XA-YD (5 carrier intra-band non-contiguous + intra-band contiguous + inter-band with 2 bands) 2 |
X, Y |
CA_XA-XA-YC, CA_XA-YD, |
CA_XA-XC-YC (5 carrier intra-band non-contiguous + intra-band contiguous + inter-band with 2 bands) 2 |
X, Y |
CA_XA-XC-YA, CA_XA-XA-YC, CA_XC-YC |
CA_XA-XA-YA-YC (5 carrier intra-band non-contiguous + intra-band contiguous + inter-band with 2 bands) 2 |
X, Y |
CA_XA-XA-YA-YA, CA_XA-XA-YC, CA_XA-YA-YC |
CA_XA-YA-ZA-ZC (5 carrier intra-band non-contiguous + intra-band contiguous + inter-band with 3 bands) 2 |
X, Y, Z |
CA_XA-YA-ZA-ZA, CA_XA-YA-ZC, CA_XA-ZA-ZC, CA_YA-ZA-ZC |
CA_XA-YA-YA-ZA-ZA (5 carrier intra-band non-contiguous + intra-band contiguous + inter-band with 3 bands) 2 |
X, Y, Z |
CA_XA-YA-YA-ZA, CA_XA-YA-ZA-ZA, CA_YA-YA-ZA-ZA |
CA_XA-YA-ZA-RA-RA (5 carrier intra-band non-contiguous + intra-band contiguous + inter-band with 4 bands) 2 |
X, Y, Z, R |
CA_XA-YA-ZA-RA, CA_XA-YA-RA-RA, CA_XA-ZA-RA-RA, CA_YA-ZA-RA-RA |
CA_XA-YA-ZA-RA-SA (5 carrier inter-band with 5 bands) |
X, Y, R, S |
CA_XA-YA-ZA-RA, CA_XA-YA-ZA -SA, CA_XA-YA -RA-SA, CA_XA-ZA-RA-SA, CA_YA-ZA-RA-SA |
Note 1: Table used for deriving default fallbacks in sections A.4.6.1,2 and 3. Note 2: Also applicable for different band orderings (e.g.. YA-XC). Note 3: Only the CA fallback configuration with 1 less CC indicated. To get the full list of fallback configurations, all fallback configurations down to 2 carrier are recursively generated. |
Table 4.1-3: 3DL CA Name/Release mapping
Number of Bands |
3CA Band Combinations |
Release for test applicability |
Name |
1 |
CA_XD |
Rel-10 |
3DL CA with TDD CA_XD |
2 |
CA_XA-YB |
Rel-11 |
3DL CA with FDD CA_XA-YB |
CA_XA-YB |
Rel-11 |
3DL CA with TDD CA_XA-YB |
|
CA_XA-YB |
Rel-12 |
3DL CA with FDD-TDD CA_XA-YB |
|
2 |
CA_XA-YC |
Rel-11 |
3DL CA with FDD CA_XA-YC |
CA_XA-YC |
Rel-11 |
3DL CA with TDD CA_XA-YC |
|
CA_XA-YC |
Rel-12 |
3DL CA with FDD-TDD CA_XA-YC |
|
3 |
CA_XA-YA-ZA |
Rel-10 |
3DL CA with FDD CA_XA-YA-ZA |
Rel-10 |
3DL CA with TDD CA_XA-YA-ZA |
||
Rel-12 |
3DL CA with FDD-TDD CA_XA-YA-ZA |
||
2 |
CA_XA-XA-YA |
Rel-11 |
3DL CA with FDD CA_XA-XA-YA |
1 |
CA_XA-XA-XA |
Rel-11 |
3DL CA with FDD CA_XA-XA-XA |
Table 4.1-4: 4DL CA Name/Release mapping
Number of Bands |
4CA Band Combinations |
Release for test applicability |
Name |
---|---|---|---|
1 |
CA_XE |
Rel-11 |
4DL CA with TDD CA_XE |
2 |
CA_XA-XD |
Rel-11 |
4DL CA with FDD CA_XA-XD |
Rel-11 |
4DL CA with TDD CA_XA-XD |
||
Rel-12 |
4DL CA with FDD-TDD CA_XA-XD |
||
2 |
CA_XB-YB |
Rel-10 |
4DL CA with FDD CA_XB-YB |
CA_XC-YB |
Rel-10 |
4DL CA with FDD CA_XC-YB |
|
Rel-12 |
4DL CA with FDD-TDD CA_XC-YB |
||
2 |
CA_XC-YC |
Rel-10 |
4DL CA with FDD CA_XC-YC |
Rel-10 |
4DL CA with TDD CA_XC-YC |
||
1 |
CA_XC-XC |
Rel-11 |
4DL CA with TDD CA_XC-XC |
2 |
CA_XA-XA-YB |
Rel-11 |
4DL CA with FDD CA_XA-XA-YB |
CA_XA-YA-YB |
Rel-11 |
4DL CA with FDD CA_XA-YA-YB |
|
3 |
CA_XA-YA-ZB |
Rel-11 |
4DL CA with FDD CA_XA-YA-ZB |
3 |
CA_XA-YA-ZC |
Rel-11 |
4DL CA with FDD CA_XA-YA-ZC |
Rel-12 |
4DL CA with FDD-TDD CA_XA-YA-ZC |
||
2 |
CA_XA-YA-YC |
Rel-11 |
4DL CA with FDD CA_XA-YA-YC |
Rel-12 |
4DL CA with FDD-TDD CA_XA-YA-YC |
||
2 |
CA_XA-XC-YA |
Rel-12 |
4DL CA with FDD-TDD CA_XA-XC-YA |
3 |
CA_XA-YA-ZC |
Rel-12 |
4DL CA with FDD-TDD_XA-YA-ZC |
2 |
CA_XA-XA-YA-YA |
Rel-11 |
4DL CA with FDD CA_XA-XA-YA-YA |
3 |
CA_XA-YA-YA-ZA |
Rel-11 |
4DL CA with FDD CA_XA-YA-YA-ZA |
Rel-12 |
4DL CA with FDD-TDD CA_XA-YA-YA-ZA |
||
4 |
CA_XA-YA-ZA-RA |
Rel-11 |
4DL CA with FDD CA_XA-YA-ZA-RA |
Rel-12 |
4DL CA with FDD-TDD CA_XA-YA-ZA-RA |
Table 4.1-5: 5DL CA Name/Release mapping
Number of Bands |
5CA Band Combinations |
Release for test applicability |
Name |
---|---|---|---|
1 |
CA_XF |
Rel-12 |
5DL CA with TDD CA_XF |
1 |
CA_XA-XE |
Rel-11 |
5DL CA with TDD CA_XA-XE |
1 |
CA_XC-XD |
Rel-11 |
5DL CA with FDD CA_XC-XD |
Rel-11 |
5DL CA with TDD CA_XC-XD |
||
1 |
CA_XA-XA-XD |
FFS |
5DL CA with FDD CA_XA-XA-XD |
FFS |
5DL CA with TDD CA_XA-XA-XD |
||
1 |
CA_XA-XC-XC |
FFS |
5DL CA with FDD CA_XA-XC-XC |
FFS |
5DL CA with TDD CA_XA-XC-XC |
||
2 |
CA_XA-YE |
Rel-11 |
5DL CA with TDD CA_XA-YE |
Rel-12 |
5DL CA with FDD-TDD CA_XA-YE |
||
2 |
CA_XC-YD |
Rel-11 |
5DL CA with FDD CA_XC-YD |
Rel-11 |
5DL CA with TDD CA_XC-YD |
||
Rel-12 |
5DL CA with FDD-TDD CA_XC-YD |
||
2 |
CA_XA-YA-YD |
Rel-11 |
5DL CA with TDD CA_XA-YA-YD |
Rel-12 |
5DL CA with FDD-TDD CA_XA-YA-YD |
||
2 |
CA_XA-YC-YC |
Rel-11 |
5DL CA with FDD CA_XA-YC-YC |
Rel-11 |
5DL CA with TDD CA_XA-YC-YC |
||
Rel-12 |
5DL CA with FDD-TDD CA_XA-YC-YC |
||
2 |
CA_XA-YA-YA-YC |
FFS |
5DL CA with FDD CA_XA-XA-XA-YC |
FFS |
5DL CA with TDD CA_XA-XA-XA-YC |
||
FFS |
5DL CA with FDD-TDD CA_XA-XA-XA-YC |
||
2 |
CA_XA-XA-YD |
Rel-11 |
5DL CA with TDD CA_XA-XA-YD |
Rel-12 |
5DL CA with FDD-TDD CA_XA-XA-YD |
||
2 |
CA_XA-XC-YC |
Rel-10 |
5DL CA with FDD CA_XA-XC-YC |
Rel-10 |
5DL CA with TDD CA_XA-XC-YC |
||
Rel-12 |
5DL CA with FDD-TDD CA_XA-XC-YC |
||
2 |
CA_XA-XA-YA-YC |
Rel-11 |
5DL CA with FDD CA_XA-XA-YA-YC |
Rel-11 |
5DL CA with TDD CA_XA-XA-YA-YC |
||
Rel-12 |
5DL CA with FDD-TDD CA_XA-XA-YA-YC |
||
2 |
CA_XA-XA-YA-YA-YA |
FFS |
5DL CA with FDD CA_XA-XA-YA-YA-YA |
FFS |
5DL CA with TDD CA_XA-XA-YA-YA-YA |
||
FFS |
5DL CA with FDD-TDD CA_XA-XA-YA-YA-YA |
||
2 |
CA_XA-XA-XA-YC |
FFS |
5DL CA with FDD CA_XA-XA-XA-YC |
FFS |
5DL CA with TDD CA_XA-XA-XA-YC |
||
FFS |
5DL CA with FDD-TDD CA_XA-XA-XA-YC |
||
3 |
CA_XA-YA-ZD |
Rel-11 |
5DL CA with TDD CA_XA-YA-ZD |
Rel-12 |
5DL CA with FDD-TDD CA_XA-YA-ZD |
||
3 |
CA_XA-YC-ZC |
Rel-11 |
5DL CA with FDD CA_XA-YC-ZC |
Rel-11 |
5DL CA with TDD CA_XA-YC-ZC |
||
Rel-12 |
5DL CA with FDD-TDD CA_XA-YC-ZC |
||
3 |
CA_XA-YA-ZA-ZC |
Rel-11 |
5DL CA with FDD CA_XA-YA-ZA-ZC |
Rel-11 |
5DL CA with TDD CA_XA-YA-ZA-ZC |
||
Rel-12 |
5DL CA with FDD-TDD CA_XA-YA-ZA-ZC |
||
3 |
CA_XA-YA-ZA-ZA-ZA |
FFS |
5DL CA with FDD CA_XA-YA-ZA-ZA-ZA |
FFS |
5DL CA with TDD CA_XA-YA-ZA-ZA-ZA |
||
FFS |
5DL CA with FDD-TDD CA_XA-YA-ZA-ZA-ZA |
||
3 |
CA_XA-YA-YA-ZC |
Rel-11 |
5DL CA with FDD CA_XA-YA-YA-ZC |
Rel-11 |
5DL CA with TDD CA_XA-YA-YA-ZC |
||
Rel-12 |
5DL CA with FDD-TDD CA_XA-YA-YA-ZC |
||
3 |
CA_XA-YA-YA-ZA-ZA |
Rel-11 |
5DL CA with FDD CA_XA-YA-YA-ZA-ZA |
Rel-11 |
5DL CA with TDD CA_XA-YA-YA-ZA-ZA |
||
Rel-12 |
5DL CA with FDD-TDD CA_XA-YA-YA-ZA-ZA |
||
4 |
CA_XA-YA-ZA-RC |
Rel-11 |
5DL CA with FDD CA_XA-YA-ZA-RC |
Rel-11 |
5DL CA with TDD CA_XA-YA-ZA-RC |
||
Rel-12 |
5DL CA with FDD-TDD CA_XA-YA-ZA-RC |
||
4 |
CA_XA-YA-ZA-RA-RA |
Rel-11 |
5DL CA with FDD CA_XA-YA-ZA-RA-RA |
Rel-11 |
5DL CA with TDD CA_XA-YA-ZA-RA-RA |
||
Rel-12 |
5DL CA with FDD-TDD CA_XA-YA-ZA-RA-RA |
||
5 |
CA_XA-YA-ZA-RA-SA |
Rel-12 |
5DL CA with FDD CA_XA-YA-ZA-RA-SA |
Rel-12 |
5DL CA with TDD CA_XA-YA-ZA-RA-SA |
||
Rel-12 |
5DL CA with FDD-TDD CA_XA-YA-ZA-RA-SA |
||
Note 1: X, Y, Z, R and S in this table correspond to different bands i.e. X != Y != Z != R != S. Note 2: The band combinations with difference appearance order of bands/sub-blocks in the band combination string are not distinguished. E.g. CA_XA-YA-YD represents the set of CA_XA-YD-YA, YD-YA-XA, YA-XA-YD and YA-YD-XA. |
Table 4.1-6: 6DL CA Name/Release mapping
Number of Bands |
6CA Band Combinations |
Release for test applicability |
Name |
---|---|---|---|
2 |
CA_XA-YF |
Rel-14 |
6DL CA with TDD CA_XA-YF |
Rel-14 |
6DL CA with FDD-TDD CA_XA-YF |
||
2 |
CA_XC-YE |
Rel-14 |
6DL CA with TDD CA_XC-YE |
Rel-14 |
6DL CA with FDD-TDD CA_XC-YE |
||
2 |
CA_XC-YE |
Rel-14 |
6DL CA with TDD CA_XD-YD |
Rel-14 |
6DL CA with FDD-TDD CA_XD-YD |
||
2 |
CA_XA-XA-YE |
Rel-14 |
6DL CA with FDD CA_XA-XA-YE |
Rel-14 |
6DL CA with TDD CA_XA-XA-YE |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-XA-YE |
||
2 |
CA_XA-YA-YE |
Rel-14 |
6DL CA with FDD CA_XA-YA-YE |
Rel-14 |
6DL CA with TDD CA_XA-YA-YE |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-YA-YE |
||
2 |
CA_XA-XA-XA-YD |
Rel-14 |
6DL CA with FDD CA_XA-XA-XA-YD |
Rel-14 |
6DL CA with TDD CA_XA-XA-XA-YD |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-XA-XA-YD |
||
2 |
CA_XA-XA-YA-YD |
Rel-14 |
6DL CA with FDD CA_XA-XA-YA-YD |
Rel-14 |
6DL CA with TDD CA_XA-XA-YA-YD |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-XA-YA-YD |
||
2 |
CA_XA-YA-YA-YD |
Rel-14 |
6DL CA with FDD CA_XA-YA-YA-YD |
Rel-14 |
6DL CA with TDD CA_XA-YA-YA-YD |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-YA-YA-YD |
||
2 |
CA_XA-XA-XA-XA-YC |
Rel-14 |
6DL CA with FDD CA_XA-XA-XA-XA-YC |
Rel-14 |
6DL CA with TDD CA_XA-XA-XA-XA-YC |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-XA-XA-XA-YC |
||
2 |
CA_XA-XA-XA-YA-YC |
Rel-14 |
6DL CA with FDD CA_XA-XA-XA-YA-YC |
Rel-14 |
6DL CA with TDD CA_XA-XA-XA-YA-YC |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-XA-XA-YA-YC |
||
2 |
CA_XA-XA-YA-YA-YC |
Rel-14 |
6DL CA with FDD CA_XA-XA-YA-YA-YC |
Rel-14 |
6DL CA with TDD CA_XA-XA-YA-YA-YC |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-XA-YA-YA-YC |
||
2 |
CA_XA-YA-YA-YA-YC |
Rel-14 |
6DL CA with FDD CA_XA-YA-YA-YA-YC |
Rel-14 |
6DL CA with TDD CA_XA-YA-YA-YA-YC |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-YA-YA-YA-YC |
||
2 |
CA_XC-YC-YC |
Rel-14 |
6DL CA with FDD CA_XC-YC-YC |
Rel-14 |
6DL CA with TDD CA_XC-YC-YC |
||
Rel-14 |
6DL CA with FDD-TDD CA_XC-YC-YC |
||
2 |
CA_XA-XA-YC-YC |
Rel-14 |
6DL CA with FDD CA_XA-XA-YC-YC |
Rel-14 |
6DL CA with TDD CA_XA-XA-YC-YC |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-XA-YC-YC |
||
2 |
CA_XA-XC-YA-YC |
Rel-14 |
6DL CA with FDD CA_XA-XC-YA-YC |
Rel-14 |
6DL CA with TDD CA_XA-XC-YA-YC |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-XC-YA-YC |
||
3 |
CA_XA-YA-ZE |
Rel-14 |
6DL CA with FDD CA_XA-YA-ZE |
Rel-14 |
6DL CA with TDD CA_XA-YA-ZE |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-YA-ZE |
||
3 |
CA_XA-YC-ZD |
Rel-14 |
6DL CA with FDD CA_XA-YC-ZD |
Rel-14 |
6DL CA with TDD CA_XA-YC-ZD |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-YC-ZD |
||
3 |
CA_XC-YC-ZC |
Rel-14 |
6DL CA with FDD CA_XC-YC-ZC |
Rel-14 |
6DL CA with TDD CA_XC-YC-ZC |
||
Rel-14 |
6DL CA with FDD-TDD CA_XC-YC-ZC |
||
3 |
CA_XA-XA-YC-ZC |
Rel-14 |
6DL CA with FDD CA_XA-XA-YC-ZC |
Rel-14 |
6DL CA with TDD CA_XA-XA-YC-ZC |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-XA-YC-ZC |
||
3 |
CA_XA-XA-YA-ZD |
Rel-14 |
6DL CA with FDD CA_XA-XA-YA-ZD |
Rel-14 |
6DL CA with TDD CA_XA-XA-YA-ZD |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-XA-YA-ZD |
||
3 |
CA_XA-XA-YA-YA-ZC |
Rel-14 |
6DL CA with FDD CA_XA-XA-YA-YA-ZC |
Rel-14 |
6DL CA with TDD CA_XA-XA-YA-YA-ZC |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-XA-YA-YA-ZC |
||
3 |
CA_XA-XA-YA-YA-ZA-ZA |
Rel-14 |
6DL CA with FDD CA_XA-XA-YA-YA-ZA-ZA |
Rel-14 |
6DL CA with TDD CA_XA-XA-YA-YA-ZA-ZA |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-XA-YA-YA-ZA-ZA |
||
4 |
CA_XA-YA-ZA-RD |
Rel-14 |
6DL CA with FDD CA_XA-YA-ZA-RD |
Rel-14 |
6DL CA with TDD CA_XA-YA-ZA-RD |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-YA-ZA-RD |
||
4 |
CA_XA-YA-ZC-RC |
Rel-14 |
6DL CA with FDD CA_XA-YA-ZC-RC |
Rel-14 |
6DL CA with TDD CA_XA-YA-ZC-RC |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-YA-ZC-RC |
||
4 |
CA_XA-YA-ZA-ZA-RC |
Rel-14 |
6DL CA with FDD CA_XA-YA-ZA-ZA-RC |
Rel-14 |
6DL CA with TDD CA_XA-YA-ZA-ZA-RC |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-YA-ZA-ZA-RC |
||
4 |
CA_XA-YA-ZA-ZA-RA-RA |
Rel-14 |
6DL CA with FDD CA_XA-YA-ZA-ZA-RA-RA |
Rel-14 |
6DL CA with TDD CA_XA-YA-ZA-ZA-RA-RA |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-YA-ZA-ZA-RA-RA |
||
5 |
CA_XA-YA-ZA-RA-SC |
Rel-14 |
6DL CA with FDD CA_XA-YA-ZA-RA-SC |
Rel-14 |
6DL CA with TDD CA_XA-YA-ZA-RA-SC |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-YA-ZA-RA-SC |
||
5 |
CA_XA-YA-ZA-RA-SA-SA |
Rel-14 |
6DL CA with FDD CA_XA-YA-ZA-RA-SA-SA |
Rel-14 |
6DL CA with TDD CA_XA-YA-ZA-RA-SA-SA |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-YA-ZA-RA-SA-SA |
||
6 |
CA_XA-YA-ZA-RA-SA-UA |
Rel-14 |
6DL CA with FDD CA_XA-YA-ZA-RA-SA-UA |
Rel-14 |
6DL CA with TDD CA_XA-YA-ZA-RA-SA-UA |
||
Rel-14 |
6DL CA with FDD-TDD CA_XA-YA-ZA-RA-SA-UA |
||
Note 1: X, Y, Z, R and S in this table correspond to different bands i.e. X != Y != Z != R != S. Note 2: The band combinations with difference appearance order of bands/sub-blocks in the band combination string are not distinguished. E.g. CA_XA-YA-YD represents the set of CA_XA-YD-YA, YD-YA-XA, YA-XA-YD and YA-YD-XA. |
Table 4.1-6: 7DL CA Name/Release mapping
Number of Bands |
7CA Band Combinations |
Release for test applicability |
Name |
3 |
CA_XA-YC-ZE |
Rel-14 |
7DL CA with FDD-TDD CA_XA-YC-ZE |
4 |
CA_XA-YA-ZC-RD |
Rel-14 |
7DL CA with FDD-TDD CA_XA-YA-ZC-RD |
Note 1: X, Y, Z and R in this table correspond to different bands i.e. X != Y != Z != R. Note 2: The band combinations with difference appearance order of bands/sub-blocks in the band combination string are not distinguished. E.g. CA_XA-YA-YD represents the set of CA_XA-YD-YA, YD-YA-XA, YA-XA-YD and YA-YD-XA Note 3: CA configurations involving downlink only operation in Band 46 are release independent from Rel-13 onwards (LAA was introduced in Rel-13). The 10 MHz channel bandwidth for Band 46 was introduced in TS 36.101 Rel-14 [2] and can be implemented in a release independent way from Rel-13. |