A.10 Timing Accuracy

25.1533GPPRelease 17TSUTRA repeater conformance testing (LCR TDD)

Frequency reference

Frame Trigger

LCR TDD Signal Generator

Spectrum analyzer

Repeater under test

Figure A.10: Measuring system set-up for Timing Accuracy.

Note that a repeater is a bi-directional device. The signal generator may need protection.

Annex B (informative):
Derivation of Test Requirements

The Test Requirements in this specification have been calculated by relaxing the Minimum Requirements of the core specification using the Test Tolerances defined in subclause 4.2. When the Test Tolerance is zero, the Test Requirement will be the same as the Minimum Requirement. When the Test Tolerance is non-zero, the Test Requirements will differ from the Minimum Requirements, and the formula used for this relaxation is given in table B.1.

Clause number

Title

Minimum Requirement in TS 25.116

Test Tolerance
(TT)

Test Requirement in TS 25.153

6

Maximum output power

In normal conditions Table 6.1

0,7 dB

Formula:

Upper limit + TT

Lower limit – TT

In normal conditions refer to Table 6.4

In extreme conditions Tabel 6.2

0,7dB

In extreme conditions refer to Table 6.5

9.1

Spectrum emission mask

Tables 9.1, 9.2 and 9.3:

“Maximum level” = X dB

1,5 dB

Formula:

Maximum level + TT

Refer to tables 9.5, 9.6 and 9.7

7

Frequency stability

7.1 minimum requirement

12 Hz

Formula:

Relative error + TT

Refer to 7.5 Test requirements

8

Out of Band Gain

Table 8.1: Out of band gain limits

0,5 dB

Formula:

Maximum level + TT

Refer to table 8.2

9.2

Spurious emissions

Tables 9.8, to 9.19

0 dB

10.1

Error Vector Magnitude

10.1.2 Minimum requirement

0 %

Formula:

RSS Stimulus EVM and Repeater EVM to get target EVM

Refer to 10.1.5 Test requirements

10.2

Peak code domain error

10.2.2Minimum requirement

1,1 dB

Formula:

Maximum error + TT

Refer to 10.2.5 Test requirements

11

Input intermodulation

11.2 Minimum requirements, and Tables 11.1 ,11.2and 11.3

1,2 dB

Maximum in-band power increase + TT

Refer to 11.5 Test requirements.

12

Output intermodulation

12.2 Minimum requirements

1,5 dB for spectrum emission mask.

0 dB for spurious emissions

Maximum level + TT

Refer to tables 9.5 to 9.19

Table B.1: Derivation of Test Requirements

Annex C (informative):
Acceptable uncertainty of Test Equipment

This informative annex specifies the critical parameters of the components of an overall Test System (e.g. signal generators, signal analysers etc.) which are necessary when assembling a Test System which complies with subclause5.1 Acceptable uncertainty of Test System. These Test Equipment parameters are fundamental to the accuracy of the overall Test System and are unlikely to be improved upon through System Calibration.

Table C.1: Equipment accuracy

Test

Equipment accuracy

Test condition

6 Output power

Not critical

Not critical

9.1 Spectrum emission mask

Not critical

Not critical

9.2 Spurious emissions

Not critical

Not critical

11 Input intermodulation (interferer requirement)

Not critical

Not critical

7 Frequency error

±10 Hz + timebase = 12 Hz

Range 0 to 500 Hz. (This is to allow for UE range that at 0,1 PPM is larger than BTS).

10.1 Error vector magnitude

±2,5 % (for single code)

P_Max-3 to P_Max – 18 dB
Applies for reading from 10% to 25%.

10.2 Peak code domain error

± 1 dB

Measurements in the range -25 dB to -30 dB at signal power = Pmax

8 Out of band gain

11 Input intermodulation

Not critical

Not critical

12 Output intermodulation

Not critical

Not critical

13 ACRR

14 Timing Accuracy

Not critical

Not critical

Annex D (informative):
Change history

Change history

Date

TSG #

TSG Doc.

CR

Rev

Subject/Comment

Old

New

2009-10

RAN4#52 bis

R4-093748

TS skeleton created from 3GPP TS template.

0.0.1

2010-02

RAN4#54

R4-100999

TS with the TP approved at RAN4#52bis and RAN4#53

R4-093756 Text proposal for TS25.153: Output Power

R4-094018 Text proposal for TS25.153: Frequency Error

R4-093752 Text proposal for TS25.153: EVM

R4-093757 Text proposal for TS25.153: PCDE

R4-093755 Text proposal for TS25.153: Output Intermodulation

R4-094017 Text proposal for TS25.153: Frequency bands and channel arrangements

R4-093753 Text proposal for TS25.153: Input Intermodulation

R4-093754 Text proposal for TS25.153:Out of Band Gain

R4-093751 Text proposal for TS25.153: ACRR

R4-094019 Text proposal for TS25.153: Timing Accuracy

R4-093759 Text proposal for TS25.153: Unwanted Emissions

R4-093760 Text proposal for 25.153: Clause 1 to Clause 3

R4-094638 Text proposal for 25.153: Clause 4

R4-094768 Text proposal for 25.153: Annex A to Annex D

R4-100998 Correction of the Figure A.10 of TS 25.153

0.0.1

1.0.0

2010-03

RAN#47

RP-100111

Presentation to TSG for approval

1.0.0

1.0.0

2010-03

RAN#47

RP-100111

Approved by TSG RAN

1.0.0

10.0.0

2012-09

SP-57

Update to Rel-11 version (MCC)

10.0.0

11.0.0

2014-09

SP-65

Update to Rel-12 version (MCC)

11.0.0

12.0.0

2016-01

SP-70

Update to Rel-13 version (MCC)

12.0.0

13.0.0

2017-03

RAN#75

Update to Rel-14 version (MCC)

13.0.0

14.0.0

Change history

Date

Meeting

TDoc

CR

Rev

Cat

Subject/Comment

New version

2018-09

RAN#81

Update to Rel-15 version (MCC)

15.0.0

2020-06

SA#88

Update to Rel-16 version (MCC)

16.0.0

2022-03

SA#95

Update to Rel-17 version (MCC)

17.0.0