5.5 Common procedures for RF testing

38.508-13GPP5GSPart 1: Common test environmentRelease 17TSUser Equipment (UE) conformance specification

5.5.1 Procedure to configure SCC for NR RF CA testing

5.5.1.1 Scope

The purpose of this procedure is to establish one or more SCC for NR CA testing.

5.5.1.2 Procedure description

5.5.1.2.1 Initial conditions

UE is operating in NR RRC_CONNECTED state on NR Cell 1 without any SCell configured.

System Simulator:

– SS configures the number of SCells used by the test case using NR parameters for NR Cell 2 for SCC1, NR Cell 3 for SCC2, NR Cell 4 for SCC3 etc. as specified in Table 4.4.2-2.

– System information combination NR-2 as defined in clause 4.4.3.1.2 is used in all NR cells.

5.5.1.2.2 Procedure sequence

Table 5.5.1.2.2-1: Procedure to configure SCC

St

Procedure

Message Sequence

TP

Verdict

U – S

Message

1

The SS transmits an RRCReconfiguration message including sCellToAddModList with SCell addition for the SCC under test.

<–

NR RRC: RRCReconfiguration

2

The UE transmits an RRCReconfigurationComplete message.

–>

NR RRC: RRCReconfigurationComplete

5.5.1.2.3 Specific message contents

Table 5.5.1.2.3-1: RRCReconfiguration-SCell(n)

Derivation Path: Table 4.6.1-13 with condition SCell_add

Information Element

Value/remark

Comment

Condition

RRCReconfiguration ::= SEQUENCE {

criticalExtensions CHOICE {

rrcReconfiguration ::= SEQUENCE {

nonCriticalExtension SEQUENCE {

masterCellGroup

CellGroupConfig-SCell(n)

n is number of SCC to be added.

}

}

}

}

Table 5.5.1.2.3-2: CellGroupConfig-SCell(n) (Table 5.5.1.2.3-1)

Derivation Path: Table 4.6.3-19 with condition SCell_add

Information Element

Value/remark

Comment

Condition

CellGroupConfig ::= SEQUENCE {

sCellToAddModList SEQUENCE (SIZE (1..maxNrofSCells)) OF SCellConfig {

n entries

n the number of SCC to be added

SCellConfig[k, k=1..n] SEQUENCE {

entry (1..n)

sCellIndex

sCellConfigCommon

ServingCellConfigCommon with condition SCell_add

}

}

5.5.2 Procedure to configure SCC for EN-DC RF CA testing

5.5.2.1 Scope

The purpose of this procedure is to establish one or more SCC for EN-DC CA testing.

5.5.2.2 Procedure description

5.5.2.2.1 Initial conditions

The UE is in RRC_CONNECTED state.

5.5.2.2.2 Procedure sequence

Table 5.5.2.2.2-1: Procedure to configure SCC

St

Procedure

Message Sequence

TP

Verdict

U – S

Message

1

The SS transmits an RRCConnectionReconfiguration message using n.

<–

RRC: RRCConnectionReconfiguration

2

The UE transmits an RRCConnectionReconfigurationComplete message.

–>

RRC: RRCConnectionReconfigurationComplete

EXCEPTION: Steps 3a1 to 3a3 describe the SS sequence depending on procedure parameters; the "lower case letter" identifies a step sequence that take place if a procedure parameter has a particular value

3a1-3a3

IF E-UTRA SCC > 0, same as TS 36.508 [2] table 5.2A.4-1, steps 1-3.

Note 1: n > 0 in step 1.

5.5.2.2.3 Specific message contents

Table 5.5.2.2.2.3-1: RRCReconfiguration (step 1, Table 5.5.2.2.2-1)

Derivation Path: Table 4.6.1-13 with condition EN-DC_SCell_add

Information Element

Value/remark

Comment

Condition

RRCReconfiguration ::= SEQUENCE {

criticalExtensions CHOICE {

rrcReconfiguration ::= SEQUENCE {

secondaryCellGroup

CellGroupConfig (n)

n is number of SCC to be added.

}

}

}

Table 5.5.2.2.2.3-2: CellGroupConfig (n) (Table 5.5.2.2.2.3-1)

Derivation Path: Table 4.6.1-13 with condition SCell_add

Information Element

Value/remark

Comment

Condition

CellGroupConfig ::= SEQUENCE {

sCellToAddModList SEQUENCE (SIZE (1..maxNrofSCells)) OF SCellConfig {

n entries

n is equal to the number of SCCs to be added

SCellConfig[ k, k=1..n]

entry (1..n)

sCellIndex

sCellConfigCommon

ServingCellConfigCommon with condition SCell_add

sCellConfigDedicated

ServingCellConfig

}

}

}