4.9.2 Test procedure to activate UE Beamlock Test Function (UBF)
38.508-13GPP5GSPart 1: Common test environmentRelease 17TSUser Equipment (UE) conformance specification
4.9.2.1 Initiation
UE is operating in FR2 in RRC_CONNECTED state.
4.9.2.2 Procedure
Table 4.9.2.2-1: Test procedure Sequence
St |
Procedure |
Message Sequence |
TP |
Verdict |
|
U – S |
Message/PDU/SDU |
||||
1 |
SS request UE to activate UE beamlock function. |
<– |
ACTIVATE BEAMLOCK |
– |
– |
2 |
UE confirms that UE beamlock function is activated |
–> |
ACTIVATE BEAMLOCK COMPLETE |
– |
– |
4.9.2.3 Specific Message contents
Table 4.9.2.3-1: ACTIVATE BEAMLOCK
Derivation Path: 38.509 clause 6.4.1 |
||||
Information Element |
Value/remark |
Comment |
Condition |
|
Protocol discriminator |
1 1 1 1 |
|||
Skip indicator |
0 0 0 0 |
|||
Message type |
1 0 1 0 0 0 0 0 |
|||
UE Beamlock test Function |
0 0 0 0 0 0 0 1 |
Tx Only |
||
UE Beamlock test Function |
0 0 0 0 0 0 1 0 |
Rx Only |
||
UE Beamlock test Function |
0 0 0 0 0 0 1 1 |
Tx and Rx |
Condition |
Explanation |
Tx Only |
Activation UE beamlock function for Tx only |
Rx Only |
Activation UE beamlock function for Rx only |
Tx and Rx |
Activation UE beamlock function for both Tx and Rx |
Table 4.9.2.3-2: ACTIVATE BEAMLOCK COMPLETE
Derivation Path: 38.509 clause 6.4.2 |
||||
Information Element |
Value/remark |
Comment |
Condition |
|
Protocol discriminator |
1 1 1 1 |
|||
Skip indicator |
0 0 0 0 |
|||
Message type |
1 0 1 0 0 0 0 1 |