5.6 MBMS Packet Counter reporting procedure
36.5093GPPEvolved Universal Terrestrial Radio Access (E-UTRA) and Evolved Packet Core (EPC)Release 17Special conformance testing functions for User Equipment (UE)TS
5.6.1 Request MBMS Packet Counter value
Figure 5.6.1-1: MBMS Packet Counter reporting procedure
5.6.1.1 General
The SS uses the MBMS Packet Counter reporting procedure to request reporting of current value of the state variable MBMS_PACKET_COUNTER.
5.6.1.2 Initiation
The SS requests the UE to report its current value of the state variable MBMS_PACKET_COUNTER by transmitting an UE TEST LOOP MODE C MBMS PACKET COUNTER REQUEST message.
5.6.1.3 Reception of UE TEST LOOP MODE C MBMS PACKET COUNTER REQUEST by the UE
Upon receiving the UE TEST LOOP MODE C MBMS PACKET COUNTER REQUEST message the UE shall:
1> if TEST_LOOP_MODE_C_ACTIVE is TRUE:
2> set the IE MBMS Packet Counter Value in the UE TEST LOOP MODE C MBMS PACKET COUNTER RESPONSE message to the value of the state variable MBMS_PACKET_COUNTER;
2> send the UE TEST LOOP MODE C MBMS PACKET COUNTER RESPONSE message.
- else:
2> the UE behaviour is unspecified.