7.4 In-channel selectivity

36.1043GPPBase Station (BS) radio transmission and receptionEvolved Universal Terrestrial Radio Access (E-UTRA)Release 18TS

In-channel selectivity (ICS) is a measure of the receiver ability to receive a wanted signal at its assigned resource block locations in the presence of an interfering signal received at a larger power spectral density. In this condition a throughput requirement shall be met for a specified reference measurement channel. The interfering signal shall be an E-UTRA signal as specified in Annex C and shall be time aligned with the wanted signal.

7.4.1 Minimum requirement

For E-UTRA, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.4.1-1 for Wide Area BS, in Table 7.4.1-2 for Local Area BS, in Table 7.4.1-3 for Home BS and in Table 7.4.1-4 for Medium Range BS.

Table 7.4.1-1 Wide Area BS in-channel selectivity for E-UTRA

E-UTRA

channel bandwidth (MHz)

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm]

Type of interfering signal

1.4

A1-4 in Annex A.1

-106.9

-87

1.4 MHz E-UTRA signal, 3 RBs

3

A1-5 in Annex A.1

-102.1

-84

3 MHz E-UTRA signal, 6 RBs

5

A1-2 in Annex A.1

-100.0

-81

5 MHz E-UTRA signal, 10 RBs

10

A1-3 in Annex A.1

-98.5

-77

10 MHz E-UTRA signal, 25 RBs

15

A1-3 in Annex A.1 (Note)

-98.5

-77

15 MHz E-UTRA signal, 25 RBs (Note)

20

A1-3 in Annex A.1 (Note)

-98.5

-77

20 MHz E-UTRA signal, 25 RBs (Note)

Note: Wanted and interfering signal are placed adjacently around Fc

Table 7.4.1-2 Local Area BS in-channel selectivity for E-UTRA

E-UTRA

channel bandwidth (MHz)

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm]

Type of interfering signal

1.4

A1-4 in Annex A.1

-98.9

-79

1.4 MHz E-UTRA signal, 3 RBs

3

A1-5 in Annex A.1

-94.1

-76

3 MHz E-UTRA signal, 6 RBs

5

A1-2 in Annex A.1

-92.0

-73

5 MHz E-UTRA signal, 10 RBs

10

A1-3 in Annex A.1 (Note 3)

A1-8 in Annex A.1 (Note 2)

-90.5

-93.2

-69

-71.8

10 MHz E-UTRA signal, 25 RBs (Note 3)

10 MHz E-UTRA interlace signal, 10 RBs (Note 2)

15

A1-3 in Annex A.1 (Note 1)

-90.5

-69

15 MHz E-UTRA signal, 25 RBs (Note 1)

20

A1-3 in Annex A.1 (Note 1)

A1-9 in Annex A.1 (Note 2)

-90.5

-93.2

-69

-71.8

20 MHz E-UTRA signal, 25 RBs (Note 1)

20 MHz E-UTRA interlace signal, 10 RBs (Note 2)

Note 1: Wanted and interfering signal are placed adjacently around Fc, this reference measurement channel and interfering signal are not applied for Band 46 and Band 49.

Note 2: Wanted and interfering signal interlaces are mirrored around Fc, this reference measurement channel and interfering signal are only applied for Band 46 and Band 49.

Note 3: This reference measurement channel and interfering signal are not applied for Band 46 and Band 49.

Table 7.4.1-3 Home BS in-channel selectivity for E-UTRA

E-UTRA

channel bandwidth (MHz)

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm]

Type of interfering signal

1.4

A1-4 in Annex A.1

-98.9

-79

1.4 MHz E-UTRA signal, 3 RBs

3

A1-5 in Annex A.1

-94.1

-76

3 MHz E-UTRA signal, 6 RBs

5

A1-2 in Annex A.1

-92.0

-73

5 MHz E-UTRA signal, 10 RBs

10

A1-3 in Annex A.1

-90.5

-69

10 MHz E-UTRA signal, 25 RBs

15

A1-3 in Annex A.1 (Note)

-90.5

-69

15 MHz E-UTRA signal, 25 RBs (Note)

20

A1-3 in Annex A.1 (Note)

-90.5

-69

20 MHz E-UTRA signal, 25 RBs (Note)

Note: Wanted and interfering signal are placed adjacently around Fc

Table 7.4.1-4 Medium Range BS in-channel selectivity for E-UTRA

E-UTRA

channel bandwidth (MHz)

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm]

Type of interfering signal

1.4

A1-4 in Annex A.1

-101.9

-82

1.4 MHz E-UTRA signal, 3 RBs

3

A1-5 in Annex A.1

-97.1

-79

3 MHz E-UTRA signal, 6 RBs

5

A1-2 in Annex A.1

-95.0

-76

5 MHz E-UTRA signal, 10 RBs

10

A1-3 in Annex A.1 (Note 3)

A1-8 in Annex A.1 (Note 2)

-93.5

-96.2

-72

-74.8

10 MHz E-UTRA signal, 25 RBs (Note 3)

10 MHz E-UTRA interlace signal, 10 RBs (Note 2)

15

A1-3 in Annex A.1 (Note 1)

-93.5

-72

15 MHz E-UTRA signal, 25 RBs (Note 1)

20

A1-3 in Annex A.1 (Note 1)

A1-9 in Annex A.1 (Note 2)

-93.5

-96.2

-72

-74.8

20 MHz E-UTRA signal, 25 RBs (Note 1)

20 MHz E-UTRA interlace signal, 10 RBs (Note 2)

Note 1: Wanted and interfering signal are placed adjacently around Fc, this reference measurement channel and interfering signal are not applied for Band 46.

Note 2: Wanted and interfering signal interlaces are mirrored around Fc, this reference measurement channel and interfering signal are only applied for Band 46.

Note 3: This reference measurement channel and interfering signal are not applied for Band 46.

For NB-IoT in-band operation, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.4.1-5 and Table 7.4.1-6 for Wide Area BS.

Table 7.4.1-5 Wide Area BS in-channel selectivity for NB-IoT in-band operation with 15kHz channel spacing

E-UTRA

channel bandwidth (MHz)

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm]

Type of interfering signal

3

FRC A14-1 in Annex A.14

-124.3

-84

3 MHz E-UTRA signal, 6 RBs (Note 2)

5

FRC A14-1 in Annex A.14

-124.3

-81

5 MHz E-UTRA signal, 10 RBs (Note 1)

10

FRC A14-1 in Annex A.14

-124.3

-77

10 MHz E-UTRA signal, 25 RBs (Note 1)

15

FRC A14-1 in Annex A.14

-124.3

-77

15 MHz E-UTRA signal, 25 RBs (Note 1)

20

FRC A14-1 in Annex A.14

-124.3

-77

20 MHz E-UTRA signal, 25 RBs (Note 1)

Note 1: Interfering signal is placed in one side of the Fc, while the NB-IoT PRB is placed on the other side. Both interfering signal and NB-IoT PRB are placed at the middle of the available PRB locations. The wanted NB-IoT tone is placed at the centre of this NB-IoT PRB.

Note 2: Interfering signal is placed from the edge of BWConfig, while the NB-IoT PRB is placed at the middle of the remaining PRB locations. The wanted NB-IoT tone is placed at the centre of this NB-IoT PRB.

Table 7.4.1-6 Wide Area BS in-channel selectivity for NB-IoT in-band operation with 3.75kHz channel spacing

E-UTRA

channel bandwidth (MHz)

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm]

Type of interfering signal

3

FRC A14-2 in Annex A.14

-133.2+[3]

-84

3 MHz E-UTRA signal, 6 RBs (Note 2)

5

FRC A14-2 in Annex A.14

-133.2+[3]

-81

5 MHz E-UTRA signal, 10 RBs (Note 1)

10

FRC A14-2 in Annex A.14

-133.2+[3]

-77

10 MHz E-UTRA signal, 25 RBs (Note 1)

15

FRC A14-2 in Annex A.14

-133.2+[3]

-77

15 MHz E-UTRA signal, 25 RBs (Note 1)

20

FRC A14-2 in Annex A.14

-133.2+[3]

-77

20 MHz E-UTRA signal, 25 RBs (Note 1)

Note 1: Interfering signal is placed in one side of the Fc, while the NB-IoT PRB is placed on the other side. Both interfering signal and NB-IoT PRB are placed at the middle of the available PRB locations. The wanted NB-IoT tone is placed at the centre of this NB-IoT PRB.

Note 2: Interfering signal is placed from the edge of BWConfig, while the NB-IoT PRB is placed at the middle of the remaining PRB locations. The wanted NB-IoT tone is placed at the centre of this NB-IoT PRB.

For NB-IoT in-band operation, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.4.1-7 and Table 7.4.1-8 for Local Area BS.

Table 7.4.1-7 Local Area BS in-channel selectivity for NB-IoT in-band operation with 15kHz channel spacing

E-UTRA

channel bandwidth (MHz)

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm]

Type of interfering signal

3

FRC A14-1 in Annex A.14

-116.3

-76

3 MHz E-UTRA signal, 6 RBs (Note 2)

5

FRC A14-1 in Annex A.14

-116.3

-73

5 MHz E-UTRA signal, 10 RBs (Note 1)

10

FRC A14-1 in Annex A.14

-116.3

-69

10 MHz E-UTRA signal, 25 RBs (Note 1)

15

FRC A14-1 in Annex A.14

-116.3

-69

15 MHz E-UTRA signal, 25 RBs (Note 1)

20

FRC A14-1 in Annex A.14

-116.3

-69

20 MHz E-UTRA signal, 25 RBs (Note 1)

Note 1: Interfering signal is placed in one side of the Fc, while the NB-IoT PRB is placed on the other side. Both interfering signal and NB-IoT PRB are placed at the middle of the available PRB locations. The wanted NB-IoT tone is placed at the centre of this NB-IoT PRB.

Note 2: Interfering signal is placed from the edge of BWConfig, while the NB-IoT PRB is placed at the middle of the remaining PRB locations. The wanted NB-IoT tone is placed at the centre of this NB-IoT PRB.

Table 7.4.1-8 Local Area BS in-channel selectivity for NB-IoT in-band operation with 3.75kHz channel spacing

E-UTRA

channel bandwidth (MHz)

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm]

Type of interfering signal

3

FRC A14-2 in Annex A.14

-122.2

-76

3 MHz E-UTRA signal, 6 RBs (Note 2)

5

FRC A14-2 in Annex A.14

-122.2

-73

5 MHz E-UTRA signal, 10 RBs (Note 1)

10

FRC A14-2 in Annex A.14

-122.2

-69

10 MHz E-UTRA signal, 25 RBs (Note 1)

15

FRC A14-2 in Annex A.14

-122.2

-69

15 MHz E-UTRA signal, 25 RBs (Note 1)

20

FRC A14-2 in Annex A.14

-122.2

-69

20 MHz E-UTRA signal, 25 RBs (Note 1)

Note 1: Interfering signal is placed in one side of the Fc, while the NB-IoT PRB is placed on the other side. Both interfering signal and NB-IoT PRB are placed at the middle of the available PRB locations. The wanted NB-IoT tone is placed at the centre of this NB-IoT PRB.

Note 2: Interfering signal is placed from the edge of BWConfig, while the NB-IoT PRB is placed at the middle of the remaining PRB locations. The wanted NB-IoT tone is placed at the centre of this NB-IoT PRB.

For NB-IoT in-band operation, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.4.1-9 and Table 7.4.1-10 for Home BS.

Table 7.4.1-9 Home BS in-channel selectivity for NB-IoT in-band operation with 15kHz channel spacing

E-UTRA

channel bandwidth (MHz)

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm]

Type of interfering signal

3

FRC A14-1 in Annex A.14

-116.3

-76

3 MHz E-UTRA signal, 6 RBs (Note 2)

5

FRC A14-1 in Annex A.14

-116.3

-73

5 MHz E-UTRA signal, 10 RBs (Note 1)

10

FRC A14-1 in Annex A.14

-116.3

-69

10 MHz E-UTRA signal, 25 RBs (Note 1)

15

FRC A14-1 in Annex A.14

-116.3

-69

15 MHz E-UTRA signal, 25 RBs (Note 1)

20

FRC A14-1 in Annex A.14

-116.3

-69

20 MHz E-UTRA signal, 25 RBs (Note 1)

Note 1: Interfering signal is placed in one side of the Fc, while the NB-IoT PRB is placed on the other side. Both interfering signal and NB-IoT PRB are placed at the middle of the available PRB locations. The wanted NB-IoT tone is placed at the centre of this NB-IoT PRB.

Note 2: Interfering signal is placed from the edge of BWConfig, while the NB-IoT PRB is placed at the middle of the remaining PRB locations. The wanted NB-IoT tone is placed at the centre of this NB-IoT PRB.

Table 7.4.1-10 Home BS in-channel selectivity for NB-IoT in-band operation with 3.75kHz channel spacing

E-UTRA

channel bandwidth (MHz)

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm]

Type of interfering signal

3

FRC A14-2 in Annex A.14

-122.2

-76

3 MHz E-UTRA signal, 6 RBs (Note 2)

5

FRC A14-2 in Annex A.14

-122.2

-73

5 MHz E-UTRA signal, 10 RBs (Note 1)

10

FRC A14-2 in Annex A.14

-122.2

-69

10 MHz E-UTRA signal, 25 RBs (Note 1)

15

FRC A14-2 in Annex A.14

-122.2

-69

15 MHz E-UTRA signal, 25 RBs (Note 1)

20

FRC A14-2 in Annex A.14

-122.2

-69

20 MHz E-UTRA signal, 25 RBs (Note 1)

Note 1: Interfering signal is placed in one side of the Fc, while the NB-IoT PRB is placed on the other side. Both interfering signal and NB-IoT PRB are placed at the middle of the available PRB locations. The wanted NB-IoT tone is placed at the centre of this NB-IoT PRB.

Note 2: Interfering signal is placed from the edge of BWConfig, while the NB-IoT PRB is placed at the middle of the remaining PRB locations. The wanted NB-IoT tone is placed at the centre of this NB-IoT PRB.

For NB-IoT in-band operation, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.4.1-11 and Table 7.4.1-12 for Medium Range BS.

Table 7.4.1-11 Medium Range BS in-channel selectivity for NB-IoT in-band operation with 15kHz channel spacing

E-UTRA

channel bandwidth (MHz)

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm]

Type of interfering signal

3

FRC A14-1 in Annex A.14

-119.3

-79

3 MHz E-UTRA signal, 6 RBs (Note 2)

5

FRC A14-1 in Annex A.14

-119.3

-76

5 MHz E-UTRA signal, 10 RBs (Note 1)

10

FRC A14-1 in Annex A.14

-119.3

-72

10 MHz E-UTRA signal, 25 RBs (Note 1)

15

FRC A14-1 in Annex A.14

-119.3

-72

15 MHz E-UTRA signal, 25 RBs (Note 1)

20

FRC A14-1 in Annex A.14

-119.3

-72

20 MHz E-UTRA signal, 25 RBs (Note 1)

Note 1: Interfering signal is placed in one side of the Fc, while the NB-IoT PRB is placed on the other side. Both interfering signal and NB-IoT PRB are placed at the middle of the available PRB locations. The wanted NB-IoT tone is placed at the centre of this NB-IoT PRB.

Note 2: Interfering signal is placed from the edge of BWConfig, while the NB-IoT PRB is placed at the middle of the remaining PRB locations. The wanted NB-IoT tone is placed at the centre of this NB-IoT PRB.

Table 7.4.1-12 Medium Range BS in-channel selectivity for NB-IoT in-band operation with 3.75kHz channel spacing

E-UTRA

channel bandwidth (MHz)

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm]

Type of interfering signal

3

FRC A14-2 in Annex A.14

-125.2

-79

3 MHz E-UTRA signal, 6 RBs (Note 2)

5

FRC A14-2 in Annex A.14

-125.2

-76

5 MHz E-UTRA signal, 10 RBs (Note 1)

10

FRC A14-2 in Annex A.14

-125.2

-72

10 MHz E-UTRA signal, 25 RBs (Note 1)

15

FRC A14-2 in Annex A.14

-125.2

-72

15 MHz E-UTRA signal, 25 RBs (Note 1)

20

FRC A14-2 in Annex A.14

-125.2

-72

20 MHz E-UTRA signal, 25 RBs (Note 1)

Note 1: Interfering signal is placed in one side of the Fc, while the NB-IoT PRB is placed on the other side. Both interfering signal and NB-IoT PRB are placed at the middle of the available PRB locations. The wanted NB-IoT tone is placed at the centre of this NB-IoT PRB.

Note 2: Interfering signal is placed from the edge of BWConfig, while the NB-IoT PRB is placed at the middle of the remaining PRB locations. The wanted NB-IoT tone is placed at the centre of this NB-IoT PRB.