7.3 Dynamic range
36.1043GPPBase Station (BS) radio transmission and receptionEvolved Universal Terrestrial Radio Access (E-UTRA)Release 18TS
The dynamic range is specified as a measure of the capability of the receiver to receive a wanted signal in the presence of an interfering signal inside the received channel bandwidth. In this condition a throughput requirement shall be met for a specified reference measurement channel. The interfering signal for the dynamic range requirement is an AWGN signal.
7.3.1 Minimum requirement
For E-UTRA, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.3.1-1 for Wide Area BS, in Table 7.3.1-2 for Local Area BS, in Table 7.3.1-3 for Home BS and in Table 7.3.1-4 for Medium Range BS.
Table 7.3.1-1: Wide Area BS dynamic range for E-UTRA carrier
E-UTRA channel bandwidth [MHz] |
Reference measurement channel |
Wanted signal mean power [dBm] |
Interfering signal mean power [dBm] / BWConfig |
Type of interfering signal |
1.4 |
FRC A2-1 in Annex A.2 |
-76.3 |
-88.7 |
AWGN |
3 |
FRC A2-2 in Annex A.2 |
-72.4 |
-84.7 |
AWGN |
5 |
FRC A2-3 in Annex A.2 |
-70.2 |
-82.5 |
AWGN |
10 |
FRC A2-3 in Annex A.2* |
-70.2 |
-79.5 |
AWGN |
15 |
FRC A2-3 in Annex A.2* |
-70.2 |
-77.7 |
AWGN |
20 |
FRC A2-3 in Annex A.2* |
-70.2 |
-76.4 |
AWGN |
Note*: The wanted signal mean power is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of FRC A2-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each. |
Table 7.3.1-2: Local Area BS dynamic range for E-UTRA carrier
E-UTRA channel bandwidth [MHz] |
Reference measurement channel |
Wanted signal mean power [dBm] |
Interfering signal mean power [dBm] / BWConfig |
Type of interfering signal |
1.4 |
FRC A2-1 in Annex A.2 |
-68.3 |
-80.7 |
AWGN |
3 |
FRC A2-2 in Annex A.2 |
-64.4 |
-76.7 |
AWGN |
5 |
FRC A2-3 in Annex A.2 |
-62.2 |
-74.5 |
AWGN |
10 |
FRC A2-3 in Annex A.2 (Note 1) FRC A2-4 in Annex A.2 (Note 2) |
-62.2 -65.3 |
-71.5 |
AWGN |
15 |
FRC A2-3 in Annex A.2 (Note 1) |
-62.2 |
-69.7 |
AWGN |
20 |
FRC A2-3 in Annex A.2 (Note 1) FRC A2-5 in Annex A.2 (Note 2) |
-62.2 -65.3 |
-68.4 |
AWGN |
Note 1: The wanted signal mean power is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of FRC A2-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each. This reference measurement channel is not applied for Band 46 and Band 49. Note 2: The wanted signal mean power is the power level of a single instance of the reference measurement channel. This requirement shall be met for each single interlace of FRC A2-4 and A2-5. This reference measurement channel is only applied for Band 46 and Band 49. |
Table 7.3.1-3: Home BS dynamic range for E-UTRA carrier
E-UTRA channel bandwidth [MHz] |
Reference measurement channel |
Wanted signal mean power [dBm] |
Interfering signal mean power [dBm] / BWConfig |
Type of interfering signal |
1.4 |
FRC A2-1 in Annex A.2 |
-31.8 |
-44.2 |
AWGN |
3 |
FRC A2-2 in Annex A.2 |
-27.9 |
-40.2 |
AWGN |
5 |
FRC A2-3 in Annex A.2 |
-25.7 |
-38 |
AWGN |
10 |
FRC A2-3 in Annex A.2* |
-25.7 |
-35 |
AWGN |
15 |
FRC A2-3 in Annex A.2* |
-25.7 |
-33.2 |
AWGN |
20 |
FRC A2-3 in Annex A.2* |
-25.7 |
-31.9 |
AWGN |
Note*: The wanted signal mean power is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of FRC A2-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each. |
Table 7.3.1-4: Medium Range BS dynamic range for E-UTRA carrier
E-UTRA channel bandwidth [MHz] |
Reference measurement channel |
Wanted signal mean power [dBm] |
Interfering signal mean power [dBm] / BWConfig |
Type of interfering signal |
1.4 |
FRC A2-1 in Annex A.2 |
-71.3 |
-83.7 |
AWGN |
3 |
FRC A2-2 in Annex A.2 |
-67.4 |
-79.7 |
AWGN |
5 |
FRC A2-3 in Annex A.2 |
-65.2 |
-77.5 |
AWGN |
10 |
FRC A2-3 in Annex A.2 (Note 1) FRC A2-4 in Annex A.2 (Note 2) |
-65.2 -68.3 |
-74.5 |
AWGN |
15 |
FRC A2-3 in Annex A.2 (Note 1) |
-65.2 |
-72.7 |
AWGN |
20 |
FRC A2-3 in Annex A.2 (Note 1) FRC A2-5 in Annex A.2 (Note 2) |
-65.2 -68.3 |
-71.4 |
AWGN |
Note 1: The wanted signal mean power is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of FRC A2-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each. This reference measurement channel is not applied for Band 46. Note 2: The wanted signal mean power is the power level of a single instance of the reference measurement channel. This requirement shall be met for each single interlace of FRC A2-4 and A2-5. This reference measurement channel is only applied for Band 46. |
For NB-IoT standalone operation, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.3.1-5 for Wide Area BS.
Table 7.3.1-5: Wide Area BS dynamic range for NB-IoT standalone operation
NB-IoT channel bandwidth [kHz] |
Reference measurement channel |
Wanted signal mean power [dBm] |
Interfering signal mean power [dBm] / BWChannel |
Type of interfering signal |
200 |
FRC A15-1 in Annex A.15 |
-99.7 |
-96 |
AWGN |
200 |
FRC A15-2 in Annex A.15 |
-105.6 |
-96 |
AWGN |
For NB-IoT in-band or guard band operation, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.3.1-6 for Wide Area BS.
Table 7.3.1-6: Wide Area BS dynamic range for NB-IoT in-band or guard band operation
NB-IoT channel bandwidth [MHz] |
Reference measurement channel |
Wanted signal mean power [dBm] |
Interfering signal mean power [dBm] / BWChannel |
Type of interfering signal |
3* |
FRC A15-1 in Annex A.15 |
-99.7 |
-84.2 |
AWGN |
FRC A15-2 in Annex A.15 |
-105.6 |
|||
5 |
FRC A15-1 in Annex A.15 |
-99.7 |
-82.0 |
AWGN |
FRC A15-2 in Annex A.15 |
-105.6 |
|||
10 |
FRC A15-1 in Annex A.15 |
-99.7 |
-79.0 |
AWGN |
FRC A15-2 in Annex A.15 |
-105.6 |
|||
15 |
FRC A15-1 in Annex A.15 |
-99.7 |
-77.2 |
AWGN |
FRC A15-2 in Annex A.15 |
-105.6 |
|||
20 |
FRC A15-1 in Annex A.15 |
-99.7 |
-76.0 |
AWGN |
FRC A15-2 in Annex A.15 |
-105.6 |
|||
Note*: 3 MHz channel bandwidth is not applicable to guard band operation. |
For NB-IoT standalone operation, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.3.1-7 for Local Area BS
Table 7.3.1-7: Local Area BS dynamic range for NB-IoT standalone operation
NB-IoT channel bandwidth [kHz] |
Reference measurement channel |
Wanted signal mean power [dBm] |
Interfering signal mean power [dBm] / BWChannel |
Type of interfering signal |
200 |
FRC A15-1 in Annex A.15 |
-91.7 |
-88 |
AWGN |
200 |
FRC A15-2 in Annex A.15 |
-97.6 |
-88 |
AWGN |
For NB-IoT in-band or guard band operation, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.3.1-8 for Local Area BS.
Table 7.3.1-8: Local Area BS dynamic range for NB-IoT in-band or guard band operation
NB-IoT channel bandwidth [MHz] |
Reference measurement channel |
Wanted signal mean power [dBm] |
Interfering signal mean power [dBm] / BWChannel |
Type of interfering signal |
3 (Note 1) |
FRC A15-1 in Annex A.15 |
-91.7 |
-76.2 |
AWGN |
FRC A15-2 in Annex A.15 |
-97.6 |
|||
5 |
FRC A15-1 in Annex A.15 |
-91.7 |
-74.0 |
AWGN |
FRC A15-2 in Annex A.15 |
-97.6 |
|||
10 |
FRC A15-1 in Annex A.15 |
-91.7 |
-71.0 |
AWGN |
FRC A15-2 in Annex A.15 |
-97.6 |
|||
15 |
FRC A15-1 in Annex A.15 |
-91.7 |
-69.2 |
AWGN |
FRC A15-2 in Annex A.15 |
-97.6 |
|||
20 |
FRC A15-1 in Annex A.15 |
-91.7 |
-68.0 |
AWGN |
FRC A15-2 in Annex A.15 |
-97.6 |
|||
Note 1: 3 MHz channel bandwidth is not applicable to guard band operation. |
For NB-IoT standalone operation, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.3.1-9 for Home BS
Table 7.3.1-9: Home BS dynamic range for NB-IoT standalone operation
NB-IoT channel bandwidth [kHz] |
Reference measurement channel |
Wanted signal mean power [dBm] |
Interfering signal mean power [dBm] / BWChannel |
Type of interfering signal |
200 |
FRC A15-1 in Annex A.15 |
-55.2 |
-51.5 |
AWGN |
200 |
FRC A15-2 in Annex A.15 |
-61.1 |
-51.5 |
AWGN |
For NB-IoT in-band or guard band operation, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.3.1-10 for Home BS.
Table 7.3.1-10: Home BS dynamic range for NB-IoT in-band or guard band operation
NB-IoT channel bandwidth [MHz] |
Reference measurement channel |
Wanted signal mean power [dBm] |
Interfering signal mean power [dBm] / BWChannel |
Type of interfering signal |
3 (Note 1) |
FRC A15-1 in Annex A.15 |
-55.2 |
-39.7 |
AWGN |
FRC A15-2 in Annex A.15 |
-61.1 |
|||
5 |
FRC A15-1 in Annex A.15 |
-55.2 |
-37.5 |
AWGN |
FRC A15-2 in Annex A.15 |
-61.1 |
|||
10 |
FRC A15-1 in Annex A.15 |
-55.2 |
-34.5 |
AWGN |
FRC A15-2 in Annex A.15 |
-61.1 |
|||
15 |
FRC A15-1 in Annex A.15 |
-55.2 |
-32.7 |
AWGN |
FRC A15-2 in Annex A.15 |
-61.1 |
|||
20 |
FRC A15-1 in Annex A.15 |
-55.2 |
-31.5 |
AWGN |
FRC A15-2 in Annex A.15 |
-61.1 |
|||
Note 1: 3 MHz channel bandwidth is not applicable to guard band operation. |
For NB-IoT standalone operation, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.3.1-11 for Medium Range BS
Table 7.3.1-11: Medium Range BS dynamic range for NB-IoT standalone operation
NB-IoT channel bandwidth [kHz] |
Reference measurement channel |
Wanted signal mean power [dBm] |
Interfering signal mean power [dBm] / BWChannel |
Type of interfering signal |
200 |
FRC A15-1 in Annex A.15 |
-94.7 |
-91 |
AWGN |
200 |
FRC A15-2 in Annex A.15 |
-100.6 |
-91 |
AWGN |
For NB-IoT in-band or guard band operation, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.3.1-12 for Medium Range BS.
Table 7.3.1-12: Medium Range BS dynamic range for NB-IoT in-band or guard band operation
NB-IoT channel bandwidth [MHz] |
Reference measurement channel |
Wanted signal mean power [dBm] |
Interfering signal mean power [dBm] / BWChannel |
Type of interfering signal |
3 (Note 1) |
FRC A15-1 in Annex A.15 |
-94.7 |
-79.2 |
AWGN |
FRC A15-2 in Annex A.15 |
-100.6 |
|||
5 |
FRC A15-1 in Annex A.15 |
-94.7 |
-77.0 |
AWGN |
FRC A15-2 in Annex A.15 |
-100.6 |
|||
10 |
FRC A15-1 in Annex A.15 |
-94.7 |
-74.0 |
AWGN |
FRC A15-2 in Annex A.15 |
-100.6 |
|||
15 |
FRC A15-1 in Annex A.15 |
-94.7 |
-72.2 |
AWGN |
FRC A15-2 in Annex A.15 |
-100.6 |
|||
20 |
FRC A15-1 in Annex A.15 |
-94.7 |
-71.0 |
AWGN |
FRC A15-2 in Annex A.15 |
-100.6 |
|||
Note 1: 3 MHz channel bandwidth is not applicable to guard band operation. |