7.3 Dynamic range

36.1043GPPBase Station (BS) radio transmission and receptionEvolved Universal Terrestrial Radio Access (E-UTRA)Release 18TS

The dynamic range is specified as a measure of the capability of the receiver to receive a wanted signal in the presence of an interfering signal inside the received channel bandwidth. In this condition a throughput requirement shall be met for a specified reference measurement channel. The interfering signal for the dynamic range requirement is an AWGN signal.

7.3.1 Minimum requirement

For E-UTRA, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.3.1-1 for Wide Area BS, in Table 7.3.1-2 for Local Area BS, in Table 7.3.1-3 for Home BS and in Table 7.3.1-4 for Medium Range BS.

Table 7.3.1-1: Wide Area BS dynamic range for E-UTRA carrier

E-UTRA

channel bandwidth [MHz]

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm] / BWConfig

Type of interfering signal

1.4

FRC A2-1 in Annex A.2

-76.3

-88.7

AWGN

3

FRC A2-2 in Annex A.2

-72.4

-84.7

AWGN

5

FRC A2-3 in Annex A.2

-70.2

-82.5

AWGN

10

FRC A2-3 in Annex A.2*

-70.2

-79.5

AWGN

15

FRC A2-3 in Annex A.2*

-70.2

-77.7

AWGN

20

FRC A2-3 in Annex A.2*

-70.2

-76.4

AWGN

Note*: The wanted signal mean power is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of FRC A2-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each.

Table 7.3.1-2: Local Area BS dynamic range for E-UTRA carrier

E-UTRA

channel bandwidth [MHz]

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm] / BWConfig

Type of interfering signal

1.4

FRC A2-1 in Annex A.2

-68.3

-80.7

AWGN

3

FRC A2-2 in Annex A.2

-64.4

-76.7

AWGN

5

FRC A2-3 in Annex A.2

-62.2

-74.5

AWGN

10

FRC A2-3 in Annex A.2 (Note 1)

FRC A2-4 in Annex A.2 (Note 2)

-62.2

-65.3

-71.5

AWGN

15

FRC A2-3 in Annex A.2 (Note 1)

-62.2

-69.7

AWGN

20

FRC A2-3 in Annex A.2 (Note 1)

FRC A2-5 in Annex A.2 (Note 2)

-62.2

-65.3

-68.4

AWGN

Note 1: The wanted signal mean power is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of FRC A2-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each. This reference measurement channel is not applied for Band 46 and Band 49.

Note 2: The wanted signal mean power is the power level of a single instance of the reference measurement channel. This requirement shall be met for each single interlace of FRC A2-4 and A2-5. This reference measurement channel is only applied for Band 46 and Band 49.

Table 7.3.1-3: Home BS dynamic range for E-UTRA carrier

E-UTRA

channel bandwidth [MHz]

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm] / BWConfig

Type of interfering signal

1.4

FRC A2-1 in Annex A.2

-31.8

-44.2

AWGN

3

FRC A2-2 in Annex A.2

-27.9

-40.2

AWGN

5

FRC A2-3 in Annex A.2

-25.7

-38

AWGN

10

FRC A2-3 in Annex A.2*

-25.7

-35

AWGN

15

FRC A2-3 in Annex A.2*

-25.7

-33.2

AWGN

20

FRC A2-3 in Annex A.2*

-25.7

-31.9

AWGN

Note*: The wanted signal mean power is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of FRC A2-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each.

Table 7.3.1-4: Medium Range BS dynamic range for E-UTRA carrier

E-UTRA

channel bandwidth [MHz]

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm] / BWConfig

Type of interfering signal

1.4

FRC A2-1 in Annex A.2

-71.3

-83.7

AWGN

3

FRC A2-2 in Annex A.2

-67.4

-79.7

AWGN

5

FRC A2-3 in Annex A.2

-65.2

-77.5

AWGN

10

FRC A2-3 in Annex A.2 (Note 1)

FRC A2-4 in Annex A.2 (Note 2)

-65.2

-68.3

-74.5

AWGN

15

FRC A2-3 in Annex A.2 (Note 1)

-65.2

-72.7

AWGN

20

FRC A2-3 in Annex A.2 (Note 1)

FRC A2-5 in Annex A.2 (Note 2)

-65.2

-68.3

-71.4

AWGN

Note 1: The wanted signal mean power is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of FRC A2-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each. This reference measurement channel is not applied for Band 46.

Note 2: The wanted signal mean power is the power level of a single instance of the reference measurement channel. This requirement shall be met for each single interlace of FRC A2-4 and A2-5. This reference measurement channel is only applied for Band 46.

For NB-IoT standalone operation, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.3.1-5 for Wide Area BS.

Table 7.3.1-5: Wide Area BS dynamic range for NB-IoT standalone operation

NB-IoT

channel bandwidth [kHz]

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm] / BWChannel

Type of interfering signal

200

FRC A15-1 in Annex A.15

-99.7

-96

AWGN

200

FRC A15-2 in Annex A.15

-105.6

-96

AWGN

For NB-IoT in-band or guard band operation, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.3.1-6 for Wide Area BS.

Table 7.3.1-6: Wide Area BS dynamic range for NB-IoT in-band or guard band operation

NB-IoT

channel bandwidth [MHz]

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm] / BWChannel

Type of interfering signal

3*

FRC A15-1 in Annex A.15

-99.7

-84.2

AWGN

FRC A15-2 in Annex A.15

-105.6

5

FRC A15-1 in Annex A.15

-99.7

-82.0

AWGN

FRC A15-2 in Annex A.15

-105.6

10

FRC A15-1 in Annex A.15

-99.7

-79.0

AWGN

FRC A15-2 in Annex A.15

-105.6

15

FRC A15-1 in Annex A.15

-99.7

-77.2

AWGN

FRC A15-2 in Annex A.15

-105.6

20

FRC A15-1 in Annex A.15

-99.7

-76.0

AWGN

FRC A15-2 in Annex A.15

-105.6

Note*: 3 MHz channel bandwidth is not applicable to guard band operation.

For NB-IoT standalone operation, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.3.1-7 for Local Area BS

Table 7.3.1-7: Local Area BS dynamic range for NB-IoT standalone operation

NB-IoT

channel bandwidth [kHz]

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm] / BWChannel

Type of interfering signal

200

FRC A15-1 in Annex A.15

-91.7

-88

AWGN

200

FRC A15-2 in Annex A.15

-97.6

-88

AWGN

For NB-IoT in-band or guard band operation, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.3.1-8 for Local Area BS.

Table 7.3.1-8: Local Area BS dynamic range for NB-IoT in-band or guard band operation

NB-IoT

channel bandwidth [MHz]

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm] / BWChannel

Type of interfering signal

3

(Note 1)

FRC A15-1 in Annex A.15

-91.7

-76.2

AWGN

FRC A15-2 in Annex A.15

-97.6

5

FRC A15-1 in Annex A.15

-91.7

-74.0

AWGN

FRC A15-2 in Annex A.15

-97.6

10

FRC A15-1 in Annex A.15

-91.7

-71.0

AWGN

FRC A15-2 in Annex A.15

-97.6

15

FRC A15-1 in Annex A.15

-91.7

-69.2

AWGN

FRC A15-2 in Annex A.15

-97.6

20

FRC A15-1 in Annex A.15

-91.7

-68.0

AWGN

FRC A15-2 in Annex A.15

-97.6

Note 1: 3 MHz channel bandwidth is not applicable to guard band operation.

For NB-IoT standalone operation, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.3.1-9 for Home BS

Table 7.3.1-9: Home BS dynamic range for NB-IoT standalone operation

NB-IoT

channel bandwidth [kHz]

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm] / BWChannel

Type of interfering signal

200

FRC A15-1 in Annex A.15

-55.2

-51.5

AWGN

200

FRC A15-2 in Annex A.15

-61.1

-51.5

AWGN

For NB-IoT in-band or guard band operation, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.3.1-10 for Home BS.

Table 7.3.1-10: Home BS dynamic range for NB-IoT in-band or guard band operation

NB-IoT

channel bandwidth [MHz]

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm] / BWChannel

Type of interfering signal

3

(Note 1)

FRC A15-1 in Annex A.15

-55.2

-39.7

AWGN

FRC A15-2 in Annex A.15

-61.1

5

FRC A15-1 in Annex A.15

-55.2

-37.5

AWGN

FRC A15-2 in Annex A.15

-61.1

10

FRC A15-1 in Annex A.15

-55.2

-34.5

AWGN

FRC A15-2 in Annex A.15

-61.1

15

FRC A15-1 in Annex A.15

-55.2

-32.7

AWGN

FRC A15-2 in Annex A.15

-61.1

20

FRC A15-1 in Annex A.15

-55.2

-31.5

AWGN

FRC A15-2 in Annex A.15

-61.1

Note 1: 3 MHz channel bandwidth is not applicable to guard band operation.

For NB-IoT standalone operation, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.3.1-11 for Medium Range BS

Table 7.3.1-11: Medium Range BS dynamic range for NB-IoT standalone operation

NB-IoT

channel bandwidth [kHz]

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm] / BWChannel

Type of interfering signal

200

FRC A15-1 in Annex A.15

-94.7

-91

AWGN

200

FRC A15-2 in Annex A.15

-100.6

-91

AWGN

For NB-IoT in-band or guard band operation, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.3.1-12 for Medium Range BS.

Table 7.3.1-12: Medium Range BS dynamic range for NB-IoT in-band or guard band operation

NB-IoT

channel bandwidth [MHz]

Reference measurement channel

Wanted signal mean power [dBm]

Interfering signal mean power [dBm] / BWChannel

Type of interfering signal

3

(Note 1)

FRC A15-1 in Annex A.15

-94.7

-79.2

AWGN

FRC A15-2 in Annex A.15

-100.6

5

FRC A15-1 in Annex A.15

-94.7

-77.0

AWGN

FRC A15-2 in Annex A.15

-100.6

10

FRC A15-1 in Annex A.15

-94.7

-74.0

AWGN

FRC A15-2 in Annex A.15

-100.6

15

FRC A15-1 in Annex A.15

-94.7

-72.2

AWGN

FRC A15-2 in Annex A.15

-100.6

20

FRC A15-1 in Annex A.15

-94.7

-71.0

AWGN

FRC A15-2 in Annex A.15

-100.6

Note 1: 3 MHz channel bandwidth is not applicable to guard band operation.