7.2 Reference sensitivity level
36.1043GPPBase Station (BS) radio transmission and receptionEvolved Universal Terrestrial Radio Access (E-UTRA)Release 18TS
The reference sensitivity power level PREFSENS is the minimum mean power received at the antenna connector at which a throughput requirement shall be met for a specified reference measurement channel.
7.2.1 Minimum requirement
For E-UTRA, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.2.1-1 for Wide Area BS, in Table 7.2.1-2 for Local Area BS, in Table 7.2.1-3 for Home BS and in Table 7.2.1-4 for Medium Range BS.
Table 7.2.1-1: E-UTRA Wide Area BS reference sensitivity levels
E-UTRA channel bandwidth [MHz] |
Reference measurement channel |
Reference sensitivity power level, PREFSENS [dBm] |
1.4 |
FRC A1-1 in Annex A.1 |
-106.8 |
3 |
FRC A1-2 in Annex A.1 |
-103.0 |
3 |
FRC A1-6 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 3) |
-103.0 (Note 2) |
5 |
FRC A1-3 in Annex A.1 |
-101.5 |
5 |
FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation |
-101.5 (Note 2) |
10 |
FRC A1-3 in Annex A.1 (Note 1) |
-101.5 |
10 |
FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 4) |
-101.5 (Note 2) |
15 |
FRC A1-3 in Annex A.1 (Note 1) |
-101.5 |
15 |
FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 4) |
-101.5 (Note 2) |
20 |
FRC A1-3 in Annex A.1 (Note 1) |
-101.5 |
20 |
FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 4) |
-101.5 (Note 2) |
Note 1: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of FRC A1-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each. Note 2: The requirements apply to BS that supports E-UTRA with NB-IoT in-band operation. Note 3: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for a single instance of FRC A1-6 mapped to the 12 E-UTRA resource blocks adjacent to the NB-IoT PRB. Note 4: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for a single instance of FRC A1-7 mapped to the 24 E-UTRA resource blocks adjacent to the NB-IoT PRB, and for each consecutive application of a single instance of FRC A1-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each. |
Table 7.2.1-2: E-UTRA Local Area BS reference sensitivity levels
E-UTRA channel bandwidth [MHz] |
Reference measurement channel |
Reference sensitivity power level, PREFSENS [dBm] |
1.4 |
FRC A1-1 in Annex A.1 |
-98.8 |
3 |
FRC A1-2 in Annex A.1 |
-95.0 |
3 |
FRC A1-6 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 4) |
-95.0 (Note 3) |
5 |
FRC A1-3 in Annex A.1 |
-93.5 |
5 |
FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation |
-93.5 (Note 3) |
10 |
FRC A1-3 in Annex A.1 (Note 1) FRC A1-8 in Annex A.1 (Note 2) |
-93.5 -96.2 |
10 |
FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 5) |
-93.5 (Note 3) |
15 |
FRC A1-3 in Annex A.1 (Note 1) |
-93.5 |
15 |
FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation(Note 5) |
-93.5 (Note 3) |
20 |
FRC A1-3 in Annex A.1(Note 1) FRC A1-9 in Annex A.1 (Note 2) |
-93.5 -96.2 |
20 |
FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 5) |
-93.5 (Note 3) |
Note 1: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of FRC A1-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each. This reference measurement channel is not applied for Band 46 and Band 49. Note 2: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for each single interlace of FRC A1-8 and A1-9. This reference measurement channel is only applied for Band 46 and Band 49. Note 3: The requirements apply to BS that supports E-UTRA with NB-IoT in-band operation. Note 4: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for a single instance of FRC A1-6 mapped to the 12 E-UTRA resource blocks adjacent to the NB-IoT PRB. Note 5: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for a single instance of FRC A1-7 mapped to the 24 E-UTRA resource blocks adjacent to the NB-IoT PRB, and for each consecutive application of a single instance of FRC A1-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each. |
Table 7.2.1-3: E-UTRA Home BS reference sensitivity levels
E-UTRA channel bandwidth [MHz] |
Reference measurement channel |
Reference sensitivity power level, PREFSENS [dBm] |
1.4 |
FRC A1-1 in Annex A.1 |
-98.8 |
3 |
FRC A1-2 in Annex A.1 |
-95.0 |
3 |
FRC A1-6 in Annex A.1 1 for E-UTRA with NB-IoT in-band operation (Note 3) |
-95.0 (Note 2) |
5 |
FRC A1-3 in Annex A.1 |
-93.5 |
5 |
FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation |
-93.5 (Note 2) |
10 |
FRC A1-3 in Annex A.1 (Note) |
-93.5 |
10 |
FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 4) |
-93.5 (Note 2) |
15 |
FRC A1-3 in Annex A.1 (Note) |
-93.5 |
15 |
FRC A1-7 in Annex A.1 for E-UTRA4with NB-IoT in-band operation (Note 4) |
-93.5 (Note 2) |
20 |
FRC A1-3 in Annex A.1 (Note) |
-93.5 |
20 |
FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 4) |
-93.5 (Note 2) |
Note 1: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of FRC A1-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each Note 2: The requirements apply to BS that supports E-UTRA with NB-IoT in-band operation. Note 3: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for a single instance of FRC A1-6 mapped to the 12 E-UTRA resource blocks adjacent to the NB-IoT PRB. Note 4: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for a single instance of FRC A1-7 mapped to the 24 E-UTRA resource blocks adjacent to the NB-IoT PRB, and for each consecutive application of a single instance of FRC A1-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each. |
Table 7.2.1-4: E-UTRA Medium Range BS reference sensitivity levels
E-UTRA channel bandwidth [MHz] |
Reference measurement channel |
Reference sensitivity power level, PREFSENS [dBm] |
1.4 |
FRC A1-1 in Annex A.1 |
-101.8 |
3 |
FRC A1-2 in Annex A.1 |
-98.0 |
3 |
FRC A1-6 in Annex A.1 1 for E-UTRA with NB-IoT in-band operation (Note 4) |
-98.0 (Note 3) |
5 |
FRC A1-3 in Annex A.1 |
-96.5 |
5 |
FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation |
-96.5 (Note 3) |
10 |
FRC A1-3 in Annex A.1 (Note 1) FRC A1-8 in Annex A.1 (Note 2) |
-96.5 -99.2 |
10 |
FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 5) |
-96.5 (Note 3) |
15 |
FRC A1-3 in Annex A.1 (Note 1) |
-96.5 |
15 |
FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 5) |
-96.5 (Note 3) |
20 |
FRC A1-3 in Annex A.1 (Note 1) FRC A1-9 in Annex A.1 (Note 2) |
-96.5 -99.2 |
20 |
FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 5) |
-96.5 (Note 3) |
Note 1: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of FRC A1-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each. This reference measurement channel is not applied for Band 46. Note 2: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for each single interlace of FRC A1-8 and A1-9. This reference measurement channel is only applied for Band 46. Note 3: The requirements apply to BS that supports E-UTRA with NB-IoT in-band operation. Note 4: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for a single instance of FRC A1-6 mapped to the 12 E-UTRA resource blocks adjacent to the NB-IoT PRB. Note 5: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for a single instance of FRC A1-7 mapped to the 24 E-UTRA resource blocks adjacent to the NB-IoT PRB, and for each consecutive application of a single instance of FRC A1-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each. |
For NB-IoT standalone BS or E-UTRA BS with NB-IoT (in-band and/or guard band), NB-IoT throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.2.1-5 for Wide Area BS, in Table 7.2.1-5a for Local Area BS, in Table 7.2.1-5b for Home BS and in Table 7.2.1-5c for Medium Range BS.
Table 7.2.1-5: NB-IoT Wide Area BS reference sensitivity levels
NB-IoT channel bandwidth [kHz] |
NB-IoT Sub-carrier spacing [kHz] |
Reference measurement channel |
Reference sensitivity power level, PREFSENS [dBm] |
200 |
15 |
FRC A14-1 in Annex A.14 |
-127.3 |
200 |
3.75 |
FRC A14-2 in Annex A.14 |
-133.3 |
Table 7.2.1-5a: NB-IoT Local Area BS reference sensitivity levels
NB-IoT channel bandwidth [kHz] |
NB-IoT Sub-carrier spacing [kHz] |
Reference measurement channel |
Reference sensitivity power level, PREFSENS [dBm] |
200 |
15 |
FRC A14-1 in Annex A.14 |
-119.3 |
200 |
3.75 |
FRC A14-2 in Annex A.14 |
-125.3 |
Table 7.2.1-5b: NB-IoT Home BS reference sensitivity levels
NB-IoT channel bandwidth [kHz] |
NB-IoT Sub-carrier spacing [kHz] |
Reference measurement channel |
Reference sensitivity power level, PREFSENS [dBm] |
200 |
15 |
FRC A14-1 in Annex A.14 |
-119.3 |
200 |
3.75 |
FRC A14-2 in Annex A.14 |
-125.3 |
Table 7.2.1-5c: NB-IoT Medium Range BS reference sensitivity levels
NB-IoT channel bandwidth [kHz] |
NB-IoT Sub-carrier spacing [kHz] |
Reference measurement channel |
Reference sensitivity power level, PREFSENS [dBm] |
200 |
15 |
FRC A14-1 in Annex A.14 |
-122.3 |
200 |
3.75 |
FRC A14-2 in Annex A.14 |
-128.3 |
Table 7.2.1-6: Void
For E-UTRA BS with subPRB allocation, subPRB allocation throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.2.1-7 for Wide Area BS, in Table 7.2.1-7a for Local Area BS, in Table 7.2.1-7b for Home BS and in Table 7.2.1-7c for Medium Range BS.
Table 7.2.1-7: SubPRB allocation for Wide Area BS reference sensitivity levels
SubPRB transmission bandwidth [kHz] |
subPRB Sub-carrier spacing [kHz] |
Reference measurement channel |
Reference sensitivity power level, PREFSENS [dBm] |
30 |
15 |
FRC A23-1 in Annex A. |
-124.7 |
Table 7.2.1-7a: subPRB allocation for Local Area BS reference sensitivity levels
SubPRB transmission bandwidth [kHz] |
subPRB Sub-carrier spacing [kHz] |
Reference measurement channel |
Reference sensitivity power level, PREFSENS [dBm] |
30 |
15 |
FRC A23-1 in Annex A. |
-116.7 |
Table 7.2.1-7b: subPRB allocation for Home BS reference sensitivity levels
SubPRB transmission bandwidth [kHz] |
subPRB Sub-carrier spacing [kHz] |
Reference measurement channel |
Reference sensitivity power level, PREFSENS [dBm] |
30 |
15 |
FRC A23-1 in Annex A. |
-116.7 |
Table 7.2.1-7c: subPRB allocation for Medium Range BS reference sensitivity levels
SubPRB transmission bandwidth [kHz] |
subPRB Sub-carrier spacing [kHz] |
Reference measurement channel |
Reference sensitivity power level, PREFSENS [dBm] |
30 |
15 |
FRC A23-1 in Annex A. |
-119.7 |