7.2 Reference sensitivity level

36.1043GPPBase Station (BS) radio transmission and receptionEvolved Universal Terrestrial Radio Access (E-UTRA)Release 18TS

The reference sensitivity power level PREFSENS is the minimum mean power received at the antenna connector at which a throughput requirement shall be met for a specified reference measurement channel.

7.2.1 Minimum requirement

For E-UTRA, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.2.1-1 for Wide Area BS, in Table 7.2.1-2 for Local Area BS, in Table 7.2.1-3 for Home BS and in Table 7.2.1-4 for Medium Range BS.

Table 7.2.1-1: E-UTRA Wide Area BS reference sensitivity levels

E-UTRA

channel bandwidth [MHz]

Reference measurement channel

Reference sensitivity power level, PREFSENS

[dBm]

1.4

FRC A1-1 in Annex A.1

-106.8

3

FRC A1-2 in Annex A.1

-103.0

3

FRC A1-6 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 3)

-103.0 (Note 2)

5

FRC A1-3 in Annex A.1

-101.5

5

FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation

-101.5 (Note 2)

10

FRC A1-3 in Annex A.1 (Note 1)

-101.5

10

FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 4)

-101.5 (Note 2)

15

FRC A1-3 in Annex A.1 (Note 1)

-101.5

15

FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 4)

-101.5 (Note 2)

20

FRC A1-3 in Annex A.1 (Note 1)

-101.5

20

FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 4)

-101.5 (Note 2)

Note 1: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of FRC A1-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each.

Note 2: The requirements apply to BS that supports E-UTRA with NB-IoT in-band operation.

Note 3: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for a single instance of FRC A1-6 mapped to the 12 E-UTRA resource blocks adjacent to the NB-IoT PRB.

Note 4: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for a single instance of FRC A1-7 mapped to the 24 E-UTRA resource blocks adjacent to the NB-IoT PRB, and for each consecutive application of a single instance of FRC A1-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each.

Table 7.2.1-2: E-UTRA Local Area BS reference sensitivity levels

E-UTRA

channel bandwidth [MHz]

Reference measurement channel

Reference sensitivity power level, PREFSENS

[dBm]

1.4

FRC A1-1 in Annex A.1

-98.8

3

FRC A1-2 in Annex A.1

-95.0

3

FRC A1-6 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 4)

-95.0 (Note 3)

5

FRC A1-3 in Annex A.1

-93.5

5

FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation

-93.5 (Note 3)

10

FRC A1-3 in Annex A.1 (Note 1)

FRC A1-8 in Annex A.1 (Note 2)

-93.5

-96.2

10

FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 5)

-93.5 (Note 3)

15

FRC A1-3 in Annex A.1 (Note 1)

-93.5

15

FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation(Note 5)

-93.5 (Note 3)

20

FRC A1-3 in Annex A.1(Note 1)

FRC A1-9 in Annex A.1 (Note 2)

-93.5

-96.2

20

FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 5)

-93.5 (Note 3)

Note 1: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of FRC A1-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each. This reference measurement channel is not applied for Band 46 and Band 49.

Note 2: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for each single interlace of FRC A1-8 and A1-9. This reference measurement channel is only applied for Band 46 and Band 49.

Note 3: The requirements apply to BS that supports E-UTRA with NB-IoT in-band operation.

Note 4: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for a single instance of FRC A1-6 mapped to the 12 E-UTRA resource blocks adjacent to the NB-IoT PRB.

Note 5: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for a single instance of FRC A1-7 mapped to the 24 E-UTRA resource blocks adjacent to the NB-IoT PRB, and for each consecutive application of a single instance of FRC A1-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each.

Table 7.2.1-3: E-UTRA Home BS reference sensitivity levels

E-UTRA

channel bandwidth [MHz]

Reference measurement channel

Reference sensitivity power level, PREFSENS

[dBm]

1.4

FRC A1-1 in Annex A.1

-98.8

3

FRC A1-2 in Annex A.1

-95.0

3

FRC A1-6 in Annex A.1 1 for E-UTRA with NB-IoT in-band operation (Note 3)

-95.0 (Note 2)

5

FRC A1-3 in Annex A.1

-93.5

5

FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation

-93.5 (Note 2)

10

FRC A1-3 in Annex A.1 (Note)

-93.5

10

FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 4)

-93.5 (Note 2)

15

FRC A1-3 in Annex A.1 (Note)

-93.5

15

FRC A1-7 in Annex A.1 for E-UTRA4with NB-IoT in-band operation (Note 4)

-93.5 (Note 2)

20

FRC A1-3 in Annex A.1 (Note)

-93.5

20

FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 4)

-93.5 (Note 2)

Note 1: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of FRC A1-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each

Note 2: The requirements apply to BS that supports E-UTRA with NB-IoT in-band operation.

Note 3: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for a single instance of FRC A1-6 mapped to the 12 E-UTRA resource blocks adjacent to the NB-IoT PRB.

Note 4: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for a single instance of FRC A1-7 mapped to the 24 E-UTRA resource blocks adjacent to the NB-IoT PRB, and for each consecutive application of a single instance of FRC A1-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each.

Table 7.2.1-4: E-UTRA Medium Range BS reference sensitivity levels

E-UTRA

channel bandwidth [MHz]

Reference measurement channel

Reference sensitivity power level, PREFSENS

[dBm]

1.4

FRC A1-1 in Annex A.1

-101.8

3

FRC A1-2 in Annex A.1

-98.0

3

FRC A1-6 in Annex A.1 1 for E-UTRA with NB-IoT in-band operation (Note 4)

-98.0 (Note 3)

5

FRC A1-3 in Annex A.1

-96.5

5

FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation

-96.5 (Note 3)

10

FRC A1-3 in Annex A.1 (Note 1)

FRC A1-8 in Annex A.1 (Note 2)

-96.5

-99.2

10

FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 5)

-96.5 (Note 3)

15

FRC A1-3 in Annex A.1 (Note 1)

-96.5

15

FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 5)

-96.5 (Note 3)

20

FRC A1-3 in Annex A.1 (Note 1)

FRC A1-9 in Annex A.1 (Note 2)

-96.5

-99.2

20

FRC A1-7 in Annex A.1 for E-UTRA with NB-IoT in-band operation (Note 5)

-96.5 (Note 3)

Note 1: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of FRC A1-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each. This reference measurement channel is not applied for Band 46.

Note 2: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for each single interlace of FRC A1-8 and A1-9. This reference measurement channel is only applied for Band 46.

Note 3: The requirements apply to BS that supports E-UTRA with NB-IoT in-band operation.

Note 4: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for a single instance of FRC A1-6 mapped to the 12 E-UTRA resource blocks adjacent to the NB-IoT PRB.

Note 5: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for a single instance of FRC A1-7 mapped to the 24 E-UTRA resource blocks adjacent to the NB-IoT PRB, and for each consecutive application of a single instance of FRC A1-3 mapped to disjoint frequency ranges with a width of 25 resource blocks each.

For NB-IoT standalone BS or E-UTRA BS with NB-IoT (in-band and/or guard band), NB-IoT throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.2.1-5 for Wide Area BS, in Table 7.2.1-5a for Local Area BS, in Table 7.2.1-5b for Home BS and in Table 7.2.1-5c for Medium Range BS.

Table 7.2.1-5: NB-IoT Wide Area BS reference sensitivity levels

NB-IoT

channel bandwidth [kHz]

NB-IoT

Sub-carrier spacing

[kHz]

Reference measurement channel

Reference sensitivity power level, PREFSENS

[dBm]

200

15

FRC A14-1 in Annex A.14

-127.3

200

3.75

FRC A14-2 in Annex A.14

-133.3

Table 7.2.1-5a: NB-IoT Local Area BS reference sensitivity levels

NB-IoT

channel bandwidth [kHz]

NB-IoT

Sub-carrier spacing

[kHz]

Reference measurement channel

Reference sensitivity power level, PREFSENS

[dBm]

200

15

FRC A14-1 in Annex A.14

-119.3

200

3.75

FRC A14-2 in Annex A.14

-125.3

Table 7.2.1-5b: NB-IoT Home BS reference sensitivity levels

NB-IoT

channel bandwidth [kHz]

NB-IoT

Sub-carrier spacing

[kHz]

Reference measurement channel

Reference sensitivity power level, PREFSENS

[dBm]

200

15

FRC A14-1 in Annex A.14

-119.3

200

3.75

FRC A14-2 in Annex A.14

-125.3

Table 7.2.1-5c: NB-IoT Medium Range BS reference sensitivity levels

NB-IoT

channel bandwidth [kHz]

NB-IoT

Sub-carrier spacing

[kHz]

Reference measurement channel

Reference sensitivity power level, PREFSENS

[dBm]

200

15

FRC A14-1 in Annex A.14

-122.3

200

3.75

FRC A14-2 in Annex A.14

-128.3

Table 7.2.1-6: Void

For E-UTRA BS with subPRB allocation, subPRB allocation throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A with parameters specified in Table 7.2.1-7 for Wide Area BS, in Table 7.2.1-7a for Local Area BS, in Table 7.2.1-7b for Home BS and in Table 7.2.1-7c for Medium Range BS.

Table 7.2.1-7: SubPRB allocation for Wide Area BS reference sensitivity levels

SubPRB

transmission bandwidth [kHz]

subPRB

Sub-carrier spacing

[kHz]

Reference measurement channel

Reference sensitivity power level, PREFSENS

[dBm]

30

15

FRC A23-1 in Annex A.

-124.7

Table 7.2.1-7a: subPRB allocation for Local Area BS reference sensitivity levels

SubPRB

transmission bandwidth [kHz]

subPRB

Sub-carrier spacing

[kHz]

Reference measurement channel

Reference sensitivity power level, PREFSENS

[dBm]

30

15

FRC A23-1 in Annex A.

-116.7

Table 7.2.1-7b: subPRB allocation for Home BS reference sensitivity levels

SubPRB

transmission bandwidth [kHz]

subPRB

Sub-carrier spacing

[kHz]

Reference measurement channel

Reference sensitivity power level, PREFSENS

[dBm]

30

15

FRC A23-1 in Annex A.

-116.7

Table 7.2.1-7c: subPRB allocation for Medium Range BS reference sensitivity levels

SubPRB

transmission bandwidth [kHz]

subPRB

Sub-carrier spacing

[kHz]

Reference measurement channel

Reference sensitivity power level, PREFSENS

[dBm]

30

15

FRC A23-1 in Annex A.

-119.7