9.6 Additional requirements for carrier aggregation
36.1013GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Release 18TSUser Equipment (UE) radio transmission and reception
This clause includes requirements for the reporting of channel state information (CSI) with the UE configured for carrier aggregation. The purpose is to verify that the channel state for each cell is correctly reported with multiple cells configured for periodic reporting.
9.6.1 Periodic reporting on multiple cells (Cell-Specific Reference Symbols)
9.6.1.1 FDD
The following requirements apply to UE Category ≥3. For CA with 2 DL CC, for the parameters specified in Table 9.6.1.1-1 and Table 9.6.1.1-2, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of Pcell and Scell reported shall be such that
wideband CQIPcell – wideband CQIScell ≥ 2
for more than 90% of the time.
Table 9.6.1.1-1: Parameters for PUCCH 1-0 static test on multiple cells (FDD, 2 DL CA)
Parameter |
Unit |
Pcell |
Scell |
||
PDSCH transmission mode |
1 |
||||
Downlink power allocation |
|
dB |
0 |
||
|
dB |
0 |
|||
Propagation condition and antenna configuration |
AWGN (1 x 2) |
||||
SNR |
dB |
10 |
4 |
||
|
dB[mW/15kHz] |
-88 |
-94 |
||
|
dB[mW/15kHz] |
-98 |
-98 |
||
Physical channel for CQI reporting |
PUCCH Format 2 |
||||
PUCCH Report Type |
4 |
||||
Reporting periodicity |
ms |
Npd = 10 |
|||
cqi-pmi-ConfigurationIndex |
11 |
16 (shift of 5 ms relative to Pcell) |
|||
Note 1: 3 symbols are allocated to PDCCH. No PDSCH for user data is scheduled for the UE with one sided dynamic OCNG Pattern OP.1 FDD as described in Annex A.5.1.1. Note 2: Void |
Table 9.6.1.1-2: PUCCH 1-0 static test (FDD, 2 DL CA)
Test number |
Bandwidth combination |
1 |
10MHz for both cells |
2 |
20MHz for both cells |
3 |
5MHz for both cells |
4 |
5MHz for PCell and 10MHz for SCell |
5 |
5MHz for PCell and 15MHz for SCell |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: Mapping of PCell and Scell to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
The following requirements for 3DL CA apply to UE Category ≥5. For CA with 3 DL CC, for the parameters specified in Table 9.6.1.1-3 and Table 9.6.1.1-4, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell1 reported, and the difference between the wideband CQI indices of SCell 1 and SCell2 reported shall be such that
wideband CQIPCell – wideband CQISCell1 ≥ 2
wideband CQISCell1 – wideband CQISCell2 ≥ 2
for more than 90% of the time.
The following requirements for 4DL CA apply to UE Category ≥8. For CA with 4 DL CC, for the parameters specified in Table 9.6.1.1-3 and Table 9.6.1.1-5, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell1 reported, and the difference between the wideband CQI indices of SCell 1 and SCell2, and SCell 1 and SCell 3 reported shall be such that
wideband CQIPCell – wideband CQISCell1 ≥ 2
wideband CQISCell1 – wideband CQISCell2 ≥ 2
wideband CQISCell1 – wideband CQISCell3 ≥ 2
for more than 90% of the time.
Table 9.6.1.1-3: Parameters for PUCCH 1-0 static test on multiple cells (FDD, 3 and 4 DL CA)
Parameter |
Unit |
Pcell |
Scell1 |
Scell2, 3 |
|
PDSCH transmission mode |
1 |
||||
Downlink power allocation |
|
dB |
0 |
||
|
dB |
0 |
|||
Propagation condition and antenna configuration |
AWGN (1 x 2) |
||||
SNR |
dB |
12 |
6 |
0 |
|
|
dB[mW/15kHz] |
-86 |
-92 |
-98 |
|
|
dB[mW/15kHz] |
-98 |
-98 |
-98 |
|
Physical channel for CQI reporting |
PUCCH Format 2 |
||||
PUCCH Report Type |
4 |
||||
Reporting periodicity |
ms |
Npd = 20 |
|||
cqi-pmi-ConfigurationIndex |
21 |
26 (shift of 5 ms relative to Pcell) |
31 for Scell2 (shift of 10 ms relative to Pcell) , 36 for Scell3 (shift of 15ms relative to Pcell) |
||
Note 1: 3 symbols are allocated to PDCCH. No PDSCH for user data is scheduled for the UE with one sided dynamic OCNG Pattern OP.1 FDD as described in Annex A.5.1.1. Note 2: Void |
Table 9.6.1.1-4: PUCCH 1-0 static test (FDD, 3 DL CA)
Test number |
Bandwidth combination (MHz) |
1 |
3×20 |
2 |
20+20+15 |
3 |
20+20+10 |
4 |
20+15+15 |
5 |
20+15+10 |
6 |
20+10+10 |
7 |
15+15+10 |
8 |
20+10+5 |
9 |
20+15+5 |
10 |
10+10+5 |
11 |
5+5+20 |
12 |
3×10 |
13 |
5+5+10 |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: If more than one cell can be configured as PCell, choose one of the cells with the smallest bandwidth as PCell. Mapping of PCell and Scells to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
Table 9.6.1.1-5: PUCCH 1-0 static test (FDD, 4 DL CA)
Test number |
Bandwidth combination (MHz) |
1 |
4×20 |
2 |
20+20+20+10 |
3 |
20+20+10+10 |
4 |
20+20+10+5 |
5 |
20+10+10+5 |
6 |
15+3×20 |
7 |
2×15+2×20 |
8 |
10+15+2×20 |
9 |
3×10+20 |
10 |
2×5+2×20 |
11 |
2×5+10+20 |
12 |
4×10 |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: If more than one cell can be configured as PCell, choose one of the cells with the smallest bandwidth as PCell. Mapping of PCell and Scells to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
The following requirements for 5DL CA apply to UE Category 8 and ≥11. For CA with 5 DL CC, for the parameters specified in Table 9.6.1.1-6 and Table 9.6.1.1-7, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell1 reported, and the difference between the wideband CQI indices of SCell 1 and SCell2, SCell 1 and SCell 3, and SCell 1 and SCell 4 reported shall be such that
wideband CQIPCell – wideband CQISCell1 ≥ 2
wideband CQISCell1 – wideband CQISCell2 ≥ 2
wideband CQISCell1 – wideband CQISCell3 ≥ 2
wideband CQISCell1 – wideband CQISCell4 ≥ 2
for more than 90% of the time.
Table 9.6.1.1-6: Parameters for PUCCH 1-0 static test on multiple cells (FDD, 5 DL CA)
Parameter |
Unit |
Pcell |
Scell1 |
Scell2, 3, 4 |
|
PDSCH transmission mode |
1 |
||||
Downlink power allocation |
|
dB |
0 |
||
|
dB |
0 |
|||
Propagation condition and antenna configuration |
AWGN (1 x 2) |
||||
SNR |
dB |
12 |
6 |
0 |
|
|
dB[mW/15kHz] |
-86 |
-92 |
-98 |
|
|
dB[mW/15kHz] |
-98 |
-98 |
-98 |
|
Physical channel for CQI reporting |
PUCCH Format 2 |
||||
PUCCH Report Type |
4 |
||||
Reporting periodicity |
ms |
Npd = 40 |
|||
cqi-pmi-ConfigurationIndex |
41 |
46 (shift of 5 ms relative to Pcell) |
51 for Scell 2 (shift of 10 ms relative to Pcell), 56 for Scell 3 (shift of 15ms relative to Pcell), 61 for Scell4 (shift of 20ms relative to Pcell) |
||
Note 1: 3 symbols are allocated to PDCCH. No PDSCH for user data is scheduled for the UE with one sided dynamic OCNG Pattern OP.1 FDD as described in Annex A.5.1.1. Note 2: Void |
Table 9.6.1.1-7: PUCCH 1-0 static test (FDD, 5 DL CA)
Test number |
Bandwidth combination (MHz) |
1 |
5×20 |
2 |
15+4×20 |
3 |
10+4×20 |
4 |
2×10+3×20 |
5 |
5+10+3×20 |
6 |
3×10+2×20 |
7 |
4×10+20 |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: If more than one cell can be configured as PCell, choose one of the cells with the smallest bandwidth as PCell. Mapping of PCell and Scells to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
The following requirements for 6DL CA apply to UE Category 8 and ≥11. For CA with 6 DL CC, for the parameters specified in Table 9.6.1.1-8 and Table 9.6.1.1-9, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell1 reported, and the difference between the wideband CQI indices of SCell 1 and SCell2, SCell 1 and SCell 3, SCell 1 and SCell 4, and SCell 1 and SCell 5 reported shall be such that
wideband CQIPCell – wideband CQISCell1 ≥ 2
wideband CQISCell1 – wideband CQISCell2 ≥ 2
wideband CQISCell1 – wideband CQISCell3 ≥ 2
wideband CQISCell1 – wideband CQISCell4 ≥ 2
wideband CQISCell1 – wideband CQISCell5 ≥ 2
for more than 90% of the time.
Table 9.6.1.1-8: Parameters for PUCCH 1-0 static test on multiple cells (FDD, 6 DL CA)
Parameter |
Unit |
Pcell |
Scell1 |
Scell2, 3, 4, 5 |
|
PDSCH transmission mode |
1 |
||||
Downlink power allocation |
|
dB |
0 |
||
|
dB |
0 |
|||
Propagation condition and antenna configuration |
AWGN (1 x 2) |
||||
SNR |
dB |
12 |
6 |
0 |
|
|
dB[mW/15kHz] |
-86 |
-92 |
-98 |
|
|
dB[mW/15kHz] |
-98 |
-98 |
-98 |
|
Physical channel for CQI reporting |
PUCCH Format 2 |
||||
PUCCH Report Type |
4 |
||||
Reporting periodicity |
ms |
Npd = 40 |
|||
cqi-pmi-ConfigurationIndex |
41 |
46 (shift of 5 ms relative to Pcell) |
51 for Scell 2 (shift of 10 ms relative to Pcell), 56 for Scell 3 (shift of 15ms relative to Pcell), 61 for Scell4 (shift of 20ms relative to Pcell), 66 for Scell5 (shift of 25ms relative to Pcell) |
||
Note 1: 3 symbols are allocated to PDCCH. No PDSCH for user data is scheduled for the UE with one sided dynamic OCNG Pattern OP.1 FDD as described in Annex A.5.1.1. Note 2: Void |
Table 9.6.1.1-9: PUCCH 1-0 static test (FDD, 6 DL CA)
Test number |
Bandwidth combination (MHz) |
1 |
6×20 |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: If more than one cell can be configured as PCell, choose one of the cells with the smallest bandwidth as PCell. Mapping of PCell and Scells to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
The following requirements for 7DL CA apply to UE Category 8 and ≥11. For CA with 7 DL CC, for the parameters specified in Table 9.6.1.1-10 and Table 9.6.1.1-11, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell1 reported, and the difference between the wideband CQI indices of SCell 1 and SCell2, SCell 1 and SCell 3, SCell 1 and SCell 4, SCell 1 and SCell 5, and SCell 1 and SCell 6 reported shall be such that
wideband CQIPCell – wideband CQISCell1 ≥ 2
wideband CQISCell1 – wideband CQISCell2 ≥ 2
wideband CQISCell1 – wideband CQISCell3 ≥ 2
wideband CQISCell1 – wideband CQISCell4 ≥ 2
wideband CQISCell1 – wideband CQISCell5 ≥ 2
wideband CQISCell1 – wideband CQISCell6 ≥ 2
for more than 90% of the time.
Table 9.6.1.1-10: Parameters for PUCCH 1-0 static test on multiple cells (FDD, 7 DL CA)
Parameter |
Unit |
Pcell |
Scell1 |
Scell2, 3, 4, 5, 6 |
|
PDSCH transmission mode |
1 |
||||
Downlink power allocation |
|
dB |
0 |
||
|
dB |
0 |
|||
Propagation condition and antenna configuration |
AWGN (1 x 2) |
||||
SNR |
dB |
12 |
6 |
0 |
|
|
dB[mW/15kHz] |
-86 |
-92 |
-98 |
|
|
dB[mW/15kHz] |
-98 |
-98 |
-98 |
|
Physical channel for CQI reporting |
PUCCH Format 2 |
||||
PUCCH Report Type |
4 |
||||
Reporting periodicity |
ms |
Npd = 40 |
|||
cqi-pmi-ConfigurationIndex |
41 |
46 (shift of 5 ms relative to Pcell) |
51 for Scell 2 (shift of 10 ms relative to Pcell), 56 for Scell 3 (shift of 15ms relative to Pcell), 61 for Scell4 (shift of 20ms relative to Pcell), 66 for Scell5 (shift of 25ms relative to Pcell), 71 for Scell6 (shift of 30ms relative to Pcell) |
||
Note 1: 3 symbols are allocated to PDCCH. No PDSCH for user data is scheduled for the UE with one sided dynamic OCNG Pattern OP.1 FDD as described in Annex A.5.1.1. Note 2: Void |
Table 9.6.1.1-11: PUCCH 1-0 static test (FDD, 7 DL CA)
Test number |
Bandwidth combination (MHz) |
1 |
7×20 |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: If more than one cell can be configured as PCell, choose one of the cells with the smallest bandwidth as PCell. Mapping of PCell and Scells to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
9.6.1.2 TDD
The following requirements apply to UE Category ≥3. For CA with 2 DL CC, for the parameters specified in Table 9.6.1.2-1 and Table 9.6.1.2-2, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of Pcell and Scell reported shall be such that
wideband CQIPcell – wideband CQIScell ≥ 2
for more than 90% of the time.
Table 9.6.1.2-1: PUCCH 1-0 static test on multiple cells (TDD, 2 DL CA)
Parameter |
Unit |
Pcell |
Scell |
||
PDSCH transmission mode |
1 |
||||
Uplink downlink configuration |
2 |
||||
Special subframe configuration |
4 |
||||
Downlink power allocation |
|
dB |
0 |
||
|
dB |
0 |
|||
Propagation condition and antenna configuration |
AWGN (1 x 2) |
||||
SNR |
dB |
10 |
4 |
||
|
dB[mW/15kHz] |
-88 |
-94 |
||
|
dB[mW/15kHz] |
-98 |
-98 |
||
Physical channel for CQI reporting |
PUCCH Format 2 |
||||
PUCCH Report Type |
4 |
||||
Reporting periodicity |
ms |
Npd = 10 |
|||
cqi-pmi-ConfigurationIndex |
8 |
13 (shift of 5 ms relative to Pcell) |
|||
Note 1: 3 symbols are allocated to PDCCH. No PDSCH for user data is scheduled for the UE with one sided dynamic OCNG Pattern OP.1 TDD as described in Annex A.5.2.1. Note 2: Void |
Table 9.6.1.2-2: PUCCH 1-0 static test (TDD, 2 DL CA)
Test number |
Bandwidth combination |
1 |
20MHz for both cells |
2 |
15MHz for PCell and 20MHz for SCell |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: Mapping of PCell and Scell to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
The following requirements for 3DL CA apply to UE Category ≥5. For CA with 3 DL CC, for the parameters specified in Table 9.6.1.2-3 and Table 9.6.1.2-4, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell1 reported, and the difference between the wideband CQI indices of SCell 1 and SCell2 reported shall be such that
wideband CQIPCell – wideband CQISCell1 ≥ 2
wideband CQISCell1 – wideband CQISCell2 ≥ 2
for more than 90% of the time.
The following requirements for 4DL CA apply to UE Category ≥8. For CA with 4 DL CC, for the parameters specified in Table 9.6.1.2-3 and Table 9.6.1.2-5, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell1 reported, and the difference between the wideband CQI indices of SCell 1 and SCell2, and SCell 1 and SCell 3 reported shall be such that
wideband CQIPCell – wideband CQISCell1 ≥ 2
wideband CQISCell1 – wideband CQISCell2 ≥ 2
wideband CQISCell1 – wideband CQISCell3 ≥ 2
for more than 90% of the time.
Table 9.6.1.2-3: PUCCH 1-0 static test on multiple cells (TDD, 3 and 4 DL CA)
Parameter |
Unit |
Pcell |
Scell1 |
Scell2, 3 |
|
PDSCH transmission mode |
1 |
||||
Uplink downlink configuration |
2 |
||||
Special subframe configuration |
4 |
||||
Downlink power allocation |
|
dB |
0 |
||
|
dB |
0 |
|||
Propagation condition and antenna configuration |
AWGN (1 x 2) |
||||
SNR |
dB |
12 |
6 |
0 |
|
|
dB[mW/15kHz] |
-86 |
-92 |
-98 |
|
|
dB[mW/15kHz] |
-98 |
-98 |
-98 |
|
Physical channel for CQI reporting |
PUCCH Format 2 |
||||
PUCCH Report Type |
4 |
||||
Reporting periodicity |
ms |
Npd = 20 |
|||
cqi-pmi-ConfigurationIndex |
18 |
23 (shift of 5 ms relative to Pcell) |
28 (shift of 10 ms relative to Pcell) , 33 for Scell3 (shift of 15ms relative to Pcell) |
||
Note 1: 3 symbols are allocated to PDCCH. No PDSCH for user data is scheduled for the UE with one sided dynamic OCNG Pattern OP.1 TDD as described in Annex A.5.2.1. Note 2: Void |
Table 9.6.1.2-4: PUCCH 1-0 static test (TDD, 3 DL CA)
Test number |
Bandwidth combination (MHz) |
1 |
3×20 |
2 |
20+20+15 |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: If more than one cell can be configured as PCell, choose one of the cells with the smallest bandwidth as PCell. Mapping of PCell and Scells to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
Table 9.6.1.2-5: PUCCH 1-0 static test (TDD, 4 DL CA)
Test number |
Bandwidth combination (MHz) |
1 |
4×20 |
2 |
20+20+20+15 |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: If more than one cell can be configured as PCell, choose one of the cells with the smallest bandwidth as PCell. Mapping of PCell and Scells to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
The following requirements for 5DL CA apply to UE Category 8 and ≥11. For CA with 5 DL CC, for the parameters specified in Table 9.6.1.2-6 and Table 9.6.1.2-7, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell1 reported, and the difference between the wideband CQI indices of SCell 1 and SCell2, SCell 1 and SCell 3, and SCell 1 and SCell 4 reported shall be such that
wideband CQIPCell – wideband CQISCell1 ≥ 2
wideband CQISCell1 – wideband CQISCell2 ≥ 2
wideband CQISCell1 – wideband CQISCell3 ≥ 2
wideband CQISCell1 – wideband CQISCell4 ≥ 2
for more than 90% of the time.
Table 9.6.1.2-6: Parameters for PUCCH 1-0 static test on multiple cells (TDD, 5 DL CA)
Parameter |
Unit |
Pcell |
Scell1 |
Scell2, 3, 4 |
|
PDSCH transmission mode |
1 |
||||
Uplink downlink configuration |
2 |
||||
Special subframe configuration |
4 |
||||
Downlink power allocation |
|
dB |
0 |
||
|
dB |
0 |
|||
Propagation condition and antenna configuration |
AWGN (1 x 2) |
||||
SNR |
dB |
12 |
6 |
0 |
|
|
dB[mW/15kHz] |
-86 |
-92 |
-98 |
|
|
dB[mW/15kHz] |
-98 |
-98 |
-98 |
|
Physical channel for CQI reporting |
PUCCH Format 2 |
||||
PUCCH Report Type |
4 |
||||
Reporting periodicity |
ms |
Npd = 40 |
|||
cqi-pmi-ConfigurationIndex |
38 |
43 (shift of 5 ms relative to Pcell) |
48 (shift of 10 ms relative to Pcell), 53 for Scell3 (shift of 15ms relative to Pcell), 5 8 for Scell4 (shift of 20ms relative to Pcell) |
||
Note 1: 3 symbols are allocated to PDCCH. No PDSCH for user data is scheduled for the UE with one sided dynamic OCNG Pattern OP.1 TDD as described in Annex A.5.2.1. Note 2: Void |
Table 9.6.1.2-7: PUCCH 1-0 static test (TDD, 5 DL CA)
Test number |
Bandwidth combination (MHz) |
1 |
5×20 |
2 |
15+4×20 |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: If more than one cell can be configured as PCell, choose one of the cells with the smallest bandwidth as PCell. Mapping of PCell and Scells to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
The following requirements for 6DL CA apply to UE Category 8 and ≥11. For CA with 6 DL CC, for the parameters specified in Table 9.6.1.2-8 and Table 9.6.1.2-9, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell1 reported, and the difference between the wideband CQI indices of SCell 1 and SCell2, SCell 1 and SCell 3, SCell 1 and SCell 4, and SCell 1 and SCell 5 reported shall be such that
wideband CQIPCell – wideband CQISCell1 ≥ [2]
wideband CQISCell1 – wideband CQISCell2 ≥ [2]
wideband CQISCell1 – wideband CQISCell3 ≥ [2]
wideband CQISCell1 – wideband CQISCell4 ≥ [2]
wideband CQISCell1 – wideband CQISCell5 ≥ [2]
for more than 90% of the time.
Table 9.6.1.2-8: Parameters for PUCCH 1-0 static test on multiple cells (TDD, 6 DL CA)
Parameter |
Unit |
Pcell |
Scell1 |
Scell2, 3, 4, 5 |
|
PDSCH transmission mode |
1 |
||||
Uplink downlink configuration |
2 |
||||
Special subframe configuration |
4 |
||||
Downlink power allocation |
|
dB |
0 |
||
|
dB |
0 |
|||
Propagation condition and antenna configuration |
AWGN (1 x 2) |
||||
SNR |
dB |
12 |
6 |
0 |
|
|
dB[mW/15kHz] |
-86 |
-92 |
-98 |
|
|
dB[mW/15kHz] |
-98 |
-98 |
-98 |
|
Physical channel for CQI reporting |
PUCCH Format 2 |
||||
PUCCH Report Type |
4 |
||||
Reporting periodicity |
ms |
Npd = 40 |
|||
cqi-pmi-ConfigurationIndex |
38 |
43 (shift of 5 ms relative to Pcell) |
48 (shift of 10 ms relative to Pcell), 53 for Scell3 (shift of 15ms relative to Pcell), 58 for Scell4 (shift of 20ms relative to Pcell), 63 for Scell5 (shift of 25ms relative to Pcell) |
||
Note 1: 3 symbols are allocated to PDCCH. No PDSCH for user data is scheduled for the UE with one sided dynamic OCNG Pattern OP.1 TDD as described in Annex A.5.2.1. Note 2: Void |
Table 9.6.1.2-9: PUCCH 1-0 static test (TDD, 6 DL CA)
Test number |
Bandwidth combination (MHz) |
1 |
6×20 |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: If more than one cell can be configured as PCell, choose one of the cells with the smallest bandwidth as PCell. Mapping of PCell and Scells to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
The following requirements for 7DL CA apply to UE Category 8 and ≥11. For CA with 7 DL CC, for the parameters specified in Table 9.6.1.2-10 and Table 9.6.1.2-11, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell1 reported, and the difference between the wideband CQI indices of SCell 1 and SCell2, SCell 1 and SCell 3, SCell 1 and SCell 4, SCell 1 and SCell 5, SCell 1 and SCell 6 reported shall be such that
wideband CQIPCell – wideband CQISCell1 ≥ [2]
wideband CQISCell1 – wideband CQISCell2 ≥ [2]
wideband CQISCell1 – wideband CQISCell3 ≥ [2]
wideband CQISCell1 – wideband CQISCell4 ≥ [2]
wideband CQISCell1 – wideband CQISCell5 ≥ [2]
wideband CQISCell1 – wideband CQISCell6 ≥ [2]
for more than 90% of the time.
Table 9.6.1.2-10: Parameters for PUCCH 1-0 static test on multiple cells (TDD, 7 DL CA)
Parameter |
Unit |
Pcell |
Scell1 |
Scell2, 3, 4, 5, 6 |
|
PDSCH transmission mode |
1 |
||||
Uplink downlink configuration |
2 |
||||
Special subframe configuration |
4 |
||||
Downlink power allocation |
|
dB |
0 |
||
|
dB |
0 |
|||
Propagation condition and antenna configuration |
AWGN (1 x 2) |
||||
SNR |
dB |
12 |
6 |
0 |
|
|
dB[mW/15kHz] |
-86 |
-92 |
-98 |
|
|
dB[mW/15kHz] |
-98 |
-98 |
-98 |
|
Physical channel for CQI reporting |
PUCCH Format 2 |
||||
PUCCH Report Type |
4 |
||||
Reporting periodicity |
ms |
Npd = 40 |
|||
cqi-pmi-ConfigurationIndex |
38 |
43 (shift of 5 ms relative to Pcell) |
48 (shift of 10 ms relative to Pcell), 53 for Scell3 (shift of 15ms relative to Pcell), 58 for Scell4 (shift of 20ms relative to Pcell), 63 for Scell5 (shift of 25ms relative to Pcell), 68 for Scell6 (shift of 30ms relative to Pcell) |
||
Note 1: 3 symbols are allocated to PDCCH. No PDSCH for user data is scheduled for the UE with one sided dynamic OCNG Pattern OP.1 TDD as described in Annex A.5.2.1. Note 2: Void |
Table 9.6.1.2-11: PUCCH 1-0 static test (TDD, 7 DL CA)
Test number |
Bandwidth combination (MHz) |
1 |
7×20 |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: If more than one cell can be configured as PCell, choose one of the cells with the smallest bandwidth as PCell. Mapping of PCell and Scells to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
9.6.1.3 TDD-FDD CA with FDD PCell
The following requirements apply to UE Category ≥5. For TDD-FDD CA with FDD PCell with 2 DL CC, for the parameters specified in Table 9.6.1.3-1 and Table 9.6.1.3-2, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell reported shall be such that
wideband CQIPCell – wideband CQISCell ≥ 2
for more than 90% of the time.
Table 9.6.1.3-1: Parameters for PUCCH 1-0 static test on multiple cells (TDD-FDD CA with FDD PCell, 2 DL CA)
Parameter |
Unit |
PCell |
SCell |
||
PDSCH transmission mode |
1 |
||||
Uplink downlink configuration |
N/A |
2 |
|||
Special subframe configuration |
N/A |
4 |
|||
Downlink power allocation |
|
dB |
0 |
||
|
dB |
0 |
|||
Propagation condition and antenna configuration |
AWGN (1 x 2) |
||||
SNR |
dB |
10 |
4 |
||
|
dB[mW/15kHz] |
-88 |
-94 |
||
|
dB[mW/15kHz] |
-98 |
-98 |
||
Physical channel for CQI reporting |
PUCCH Format 2 |
||||
PUCCH Report Type |
4 |
||||
Reporting periodicity |
ms |
Npd = 10 |
|||
cqi-pmi-ConfigurationIndex |
9 |
14 (shift of 5 ms relative to Pcell) |
|||
Note 1: 3 symbols are allocated to PDCCH. No PDSCH for user data is scheduled for the UE with one sided dynamic OCNG Pattern OP.1 FDD and OP.1 TDD as described in Annex A.5.1.1 and A.5.2.1. Note 2: Void Note 3: Void |
Table 9.6.1.3-2: PUCCH 1-0 static test (TDD-FDD CA with FDD PCell, 2 DL CA)
Test number |
Bandwidth combination |
1 |
20MHz for FDD cell and 20MHz for TDD cell |
2 |
10MHz for FDD cell and 20MHz for TDD cell |
3 |
15MHz for FDD cell and 20MHz for TDD cell |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2A. The test coverage for different number of component carriers is defined in 9.1.1.3. |
The following requirements for 3DL CA apply to UE Category ≥5. For TDD-FDD CA with FDD PCell with 3 DL CC, for the parameters specified in Table 9.6.1.3-3 and Table 9.6.1.3-4, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell1 reported, and the difference between the wideband CQI indices of SCell1 and SCell2 reported shall be such that
wideband CQIPCell – wideband CQISCell1 ≥ 2
wideband CQISCell1 – wideband CQISCell2 ≥ 2
for more than 90% of the time.
The following requirements for 4DL CA apply to UE Cateogry ≥8. For TDD-FDD CA with FDD PCell with 4 DL CC, for the parameters specified in Table 9.6.1.3-3 and Table 9.6.1.3-5, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell1 reported, and the difference between the wideband CQI indices of SCell1 and SCell2, and SCell1 and SCell3 reported shall be such that
wideband CQIPCell – wideband CQISCell1 ≥ 2
wideband CQISCell1 – wideband CQISCell2 ≥ 2
wideband CQISCell1 – wideband CQISCell3 ≥ 2
for more than 90% of the time.
Table 9.6.1.3-3: PUCCH 1-0 static test on multiple cells (TDD-FDD CA with FDD PCell, 3 and 4 DL CA)
Parameter |
Unit |
PCell |
SCell1 |
SCell2, SCell3 |
|
PDSCH transmission mode |
1 |
||||
Uplink downlink configuration |
N/A |
2 for TDD Cell N/A for FDD Cell |
|||
Special subframe configuration |
N/A |
4 for TDD Cell N/A for FDD Cell |
|||
Downlink power allocation |
|
dB |
0 |
||
|
dB |
0 |
|||
Propagation condition and antenna configuration |
AWGN (1 x 2) |
||||
SNR |
dB |
12 |
6 |
0 |
|
|
dB[mW/15kHz] |
-86 |
-92 |
-98 |
|
|
dB[mW/15kHz] |
-98 |
-98 |
-98 |
|
Physical channel for CQI reporting |
PUCCH Format 2 |
||||
PUCCH Report Type |
4 |
||||
Reporting periodicity |
ms |
Npd = 20 |
|||
cqi-pmi-ConfigurationIndex |
19 |
24 (shift of 5 ms relative to Pcell) |
29 for SCell 2 (shift of 10 ms relative to Pcell) , 34 for SCell 3 (shift of 15ms relative to PCell) |
||
Note 1: 3 symbols are allocated to PDCCH. No PDSCH for user data is scheduled for the UE with one sided dynamic OCNG Pattern OP.1 FDD and OP.1 TDD as described in Annex A.5.1.1 and A.5.2.1. Note 2: Void Note 3: Void |
Table 9.6.1.3-4: PUCCH 1-0 static test (TDD-FDD CA with FDD PCell, 3 DL CA)
Test number |
Bandwidth combination (MHz) |
1 |
20MHz for FDD cell and 2x20MHz for TDD cell |
2 |
15MHz for FDD cell and 2x20MHz for TDD cell |
3 |
10MHz for FDD cell and 2x20MHz for TDD cell |
4 |
2x20MHz for FDD cell and 20MHz for TDD cell |
5 |
20+15MHz for FDD cell and 20MHz for TDD cell |
6 |
20+10MHz for FDD cell and 20MHz for TDD cell |
7 |
2x10MHz for FDD cell and 20MHz for TDD cell |
8 |
10MHz for FDD cell and 15+20MHz for TDD cell |
9 |
10+15MHz for FDD cell and 20MHz for TDD cell |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2A. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: If more than one cell can be configured as PCell, choose one of the cells with the smallest bandwidth as PCell. Mapping of PCell and Scells to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
Table 9.6.1.3-5: PUCCH 1-0 static test (TDD-FDD CA with FDD PCell, 4 DL CA)
Test number |
Bandwidth combination (MHz) |
1 |
20MHz for FDD cell and 3x20MHz for TDD cell |
2 |
2x20MHz for FDD cell and 2x20MHz for TDD cell |
3 |
20+15MHz for FDD cell and 2x20MHz for TDD cell |
4 |
2x15MHz for FDD cell and 2x20MHz for TDD cell |
5 |
2×20+15MHz for FDD cell and 20MHz for TDD cell |
6 |
2×15+20MHz for FDD cell and 20MHz for TDD cell |
7 |
2×20+10MHz for FDD cell and 20MHz for TDD cell |
8 |
3x20MHz for FDD cell and 20MHz for TDD cell |
9 |
10MHz for FDD cell and 3x20MHz for TDD cell |
10 |
2x10MHz for FDD cell and 2x20MHz for TDD cell |
11 |
2x10MHz for FDD cell and 20+15MHz for TDD cell |
12 |
10+20MHz for FDD cell and 2x20MHz for TDD cell |
13 |
10+15MHz for FDD cell and 2x20MHz for TDD cell |
14 |
10+15+20MHz for FDD cell and 20MHz for TDD cell |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2A. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: If more than one cell can be configured as PCell, choose one of the cells with the smallest bandwidth as PCell. Mapping of PCell and Scells to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
The following requirements for 5DL CA apply to UE Category 8 and ≥11. For TDD-FDD CA with FDD PCell with 5 DL CC, for the parameters specified in Table 9.6.1.3-6 and Table 9.6.1.3-7, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell1 reported, and the difference between the wideband CQI indices of SCell1 and SCell2, SCell1 and SCell3, and SCell 1 and SCell 4 reported shall be such that
wideband CQIPCell – wideband CQISCell1 ≥ 2
wideband CQISCell1 – wideband CQISCell2 ≥ 2
wideband CQISCell1 – wideband CQISCell3 ≥ 2
wideband CQISCell1 – wideband CQISCell4 ≥ 2
for more than 90% of the time.
Table 9.6.1.3-6: PUCCH 1-0 static test on multiple cells (TDD-FDD CA with FDD PCell, 5 DL CA)
Parameter |
Unit |
PCell |
SCell1 |
SCell2, SCell3, SCell4 |
|
PDSCH transmission mode |
1 |
||||
Uplink downlink configuration |
N/A |
2 for TDD Cell N/A for FDD Cell |
|||
Special subframe configuration |
N/A |
4 for TDD Cell N/A for FDD Cell |
|||
Downlink power allocation |
|
dB |
0 |
||
|
dB |
0 |
|||
Propagation condition and antenna configuration |
AWGN (1 x 2) |
||||
SNR |
dB |
12 |
6 |
0 |
|
|
dB[mW/15kHz] |
-86 |
-92 |
-98 |
|
|
dB[mW/15kHz] |
-98 |
-98 |
-98 |
|
Physical channel for CQI reporting |
PUCCH Format 2 |
||||
PUCCH Report Type |
4 |
||||
Reporting periodicity |
ms |
Npd = 40 |
|||
cqi-pmi-ConfigurationIndex |
39 |
44 (shift of 5 ms relative to Pcell) |
49 for SCell 2 (shift of 10 ms relative to Pcell), 54 for SCell 3 (shift of 15 ms relative to Pcell), 59 for SCell 4 (shift of 20 ms relative to Pcell) |
||
Note 1: 3 symbols are allocated to PDCCH. No PDSCH for user data is scheduled for the UE with one sided dynamic OCNG Pattern OP.1 FDD and OP.1 TDD as described in Annex A.5.1.1 and A.5.2.1. Note 2: Void Note 3: Void |
Table 9.6.1.3-7: PUCCH 1-0 static test (TDD-FDD CA with FDD PCell, 5 DL CA)
Test number |
Bandwidth combination (MHz) |
1 |
15MHz+2×20MHz for FDD cell and 2x20MHz for TDD cell |
2 |
2×15MHz+20MHz for FDD cell and 2x20MHz for TDD cell |
3 |
4×20(FDD)+20(TDD)MHz |
4 |
3×20(FDD)+2×20(TDD)MHz |
5 |
2×20(FDD)+3×20(TDD)NA |
6 |
20(FDD)+4×20(TDD)MHz |
7 |
10(FDD)+4×20(TDD)MHz |
8 |
2×10(FDD)+3×20(TDD)MH |
9 |
10+20(FDD)+3×20(TDD)MHz |
10 |
10+2×20(FDD)+2×20(TDD)MHz |
11 |
10+15+20(FDD)+2×20(TDD)MHz |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2A. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: If more than one cell can be configured as PCell, choose one of the cells with the smallest bandwidth as PCell. Mapping of PCell and Scells to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
The following requirements for 6DL CA apply to UE Category 8 and ≥11. For TDD-FDD CA with FDD PCell with 6 DL CC, for the parameters specified in Table 9.6.1.3-8 and Table 9.6.1.3-9, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell1 reported, and the difference between the wideband CQI indices of SCell1 and SCell2, SCell1 and SCell3, SCell 1 and SCell 4, and SCell 1 and SCell 5 reported shall be such that
wideband CQIPCell – wideband CQISCell1 ≥ 2
wideband CQISCell1 – wideband CQISCell2 ≥ 2
wideband CQISCell1 – wideband CQISCell3 ≥ 2
wideband CQISCell1 – wideband CQISCell4 ≥ 2
wideband CQISCell1 – wideband CQISCell5 ≥ 2
for more than 90% of the time.
Table 9.6.1.3-8: PUCCH 1-0 static test on multiple cells (TDD-FDD CA with FDD PCell, 6 DL CA)
Parameter |
Unit |
PCell |
SCell1 |
SCell2, SCell3, SCell4, SCell5 |
|
PDSCH transmission mode |
1 |
||||
Uplink downlink configuration |
N/A |
2 for TDD Cell N/A for FDD Cell |
|||
Special subframe configuration |
N/A |
4 for TDD Cell N/A for FDD Cell |
|||
Downlink power allocation |
|
dB |
0 |
||
|
dB |
0 |
|||
Propagation condition and antenna configuration |
AWGN (1 x 2) |
||||
SNR |
dB |
12 |
6 |
0 |
|
|
dB[mW/15kHz] |
-86 |
-92 |
-98 |
|
|
dB[mW/15kHz] |
-98 |
-98 |
-98 |
|
Physical channel for CQI reporting |
PUCCH Format 2 |
||||
PUCCH Report Type |
4 |
||||
Reporting periodicity |
ms |
Npd = 40 |
|||
cqi-pmi-ConfigurationIndex |
39 |
44 (shift of 5 ms relative to Pcell) |
49 for SCell 2 (shift of 10 ms relative to Pcell), 54 for SCell 3 (shift of 15 ms relative to Pcell), 59 for SCell 4 (shift of 20 ms relative to Pcell), 64 for SCell 5 (shift of 25 ms relative to Pcell) |
||
Note 1: 3 symbols are allocated to PDCCH. No PDSCH for user data is scheduled for the UE with one sided dynamic OCNG Pattern OP.1 FDD and OP.1 TDD as described in Annex A.5.1.1 and A.5.2.1. Note 2: Void Note 3: Void |
Table 9.6.1.3-9: PUCCH 1-0 static test (TDD-FDD CA with FDD PCell, 6 DL CA)
Test number |
Bandwidth combination (MHz) |
1 |
1×20(FDD)+5×20(TDD) |
2 |
2×20(FDD)+4×20(TDD) |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2A. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: If more than one cell can be configured as PCell, choose one of the cells with the smallest bandwidth as PCell. Mapping of PCell and Scells to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
The following requirements for 7DL CA apply to UE Category 8 and ≥11. For TDD-FDD CA with FDD PCell with 7 DL CC, for the parameters specified in Table 9.6.1.3-10 and Table 9.6.1.3-11, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell1 reported, and the difference between the wideband CQI indices of SCell1 and SCell2, SCell1 and SCell3, SCell 1 and SCell 4, SCell 1 and SCell 5, SCell 1 and SCell 6 reported shall be such that
wideband CQIPCell – wideband CQISCell1 ≥ 2
wideband CQISCell1 – wideband CQISCell2 ≥ 2
wideband CQISCell1 – wideband CQISCell3 ≥ 2
wideband CQISCell1 – wideband CQISCell4 ≥ 2
wideband CQISCell1 – wideband CQISCell5 ≥ 2
wideband CQISCell1 – wideband CQISCell6 ≥ 2
for more than 90% of the time.
Table 9.6.1.3-10: PUCCH 1-0 static test on multiple cells (TDD-FDD CA with FDD PCell, 7 DL CA)
Parameter |
Unit |
PCell |
SCell1 |
SCell2, SCell3, SCell4, SCell5, SCell6 |
|
PDSCH transmission mode |
1 |
||||
Uplink downlink configuration |
N/A |
2 for TDD Cell N/A for FDD Cell |
|||
Special subframe configuration |
N/A |
4 for TDD Cell N/A for FDD Cell |
|||
Downlink power allocation |
|
dB |
0 |
||
|
dB |
0 |
|||
Propagation condition and antenna configuration |
AWGN (1 x 2) |
||||
SNR |
dB |
12 |
6 |
0 |
|
|
dB[mW/15kHz] |
-86 |
-92 |
-98 |
|
|
dB[mW/15kHz] |
-98 |
-98 |
-98 |
|
Physical channel for CQI reporting |
PUCCH Format 2 |
||||
PUCCH Report Type |
4 |
||||
Reporting periodicity |
ms |
Npd = 40 |
|||
cqi-pmi-ConfigurationIndex |
39 |
44 (shift of 5 ms relative to Pcell) |
49 for SCell 2 (shift of 10 ms relative to Pcell), 54 for SCell 3 (shift of 15 ms relative to Pcell), 59 for SCell 4 (shift of 20 ms relative to Pcell), 64 for SCell 5 (shift of 25 ms relative to Pcell), 69 for SCell 6 (shift of 30 ms relative to Pcell) |
||
Note 1: 3 symbols are allocated to PDCCH. No PDSCH for user data is scheduled for the UE with one sided dynamic OCNG Pattern OP.1 FDD and OP.1 TDD as described in Annex A.5.1.1 and A.5.2.1. Note 2: Void Note 3: Void |
Table 9.6.1.3-11: PUCCH 1-0 static test (TDD-FDD CA with FDD PCell, 7 DL CA)
Test number |
Bandwidth combination (MHz) |
1 |
1×20(FDD)+6×20(TDD) |
2 |
2×20(FDD)+5×20(TDD) |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2A. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: If more than one cell can be configured as PCell, choose one of the cells with the smallest bandwidth as PCell. Mapping of PCell and Scells to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
9.6.1.4 TDD-FDD CA with TDD PCell
The following requirements apply to UE Category ≥5. For TDD-FDD CA with TDD PCell with 2 DL CC, for the parameters specified in Table 9.6.1.4-1 and Table 9.6.1.4-2, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell reported shall be such that
wideband CQIPCell – wideband CQISCell ≥ 2
for more than 90% of the time.
Table 9.6.1.4-1: Parameters for PUCCH 1-0 static test on multiple cells (TDD-FDD CA with TDD PCell, 2 DL CA)
Parameter |
Unit |
PCell |
SCell |
||
PDSCH transmission mode |
1 |
||||
Uplink downlink configuration |
2 |
N/A |
|||
Special subframe configuration |
4 |
N/A |
|||
Downlink power allocation |
|
dB |
0 |
||
|
dB |
0 |
|||
Propagation condition and antenna configuration |
AWGN (1 x 2) |
||||
SNR |
dB |
10 |
4 |
||
|
dB[mW/15kHz] |
-88 |
-94 |
||
|
dB[mW/15kHz] |
-98 |
-98 |
||
Physical channel for CQI reporting |
PUCCH Format 2 |
||||
PUCCH Report Type |
4 |
||||
Reporting periodicity |
ms |
Npd = 10 |
|||
cqi-pmi-ConfigurationIndex |
8 |
13 (shift of 5 ms relative to Pcell) |
|||
Note 1: 3 symbols are allocated to PDCCH. No PDSCH for user data is scheduled for the UE with one sided dynamic OCNG Pattern OP.1 FDD and OP.1 TDD as described in Annex A.5.1.1 and A.5.2.1. Note 2: Void Note 3: Void |
Table 9.6.1.4-2: PUCCH 1-0 static test (TDD-FDD CA with TDD PCell, 2 DL CA)
Test number |
Bandwidth combination |
1 |
20MHz for TDD cell and 20MHz for FDD cell |
2 |
20MHz for TDD cell and 10MHz for FDD cell |
3 |
20MHz for TDD cell and 15MHz for FDD cell |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2A. The test coverage for different number of component carriers is defined in 9.1.1.3. |
The following requirements for 3DL CA apply to UE Category ≥5. For TDD-FDD CA with TDD PCell with 3 DL CC, for the parameters specified in Table 9.6.1.4-3 and Table 9.6.1.4-4, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell1 reported, and the difference between the wideband CQI indices of SCell1 and SCell2 reported shall be such that
wideband CQIPCell – wideband CQISCell1 ≥ 2
wideband CQISCell1 – wideband CQISCell2 ≥ 2
for more than 90% of the time.
The following requirements for 4DL CA apply to UE Cateogry ≥8. For TDD-FDD CA with TDD PCell with 4 DL CC, for the parameters specified in Table 9.6.1.4-3 and Table 9.6.1.4-5, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell1 reported, and the difference between the wideband CQI indices of SCell1 and SCell2, and SCell1 and SCell3 reported shall be such that
wideband CQIPCell – wideband CQISCell1 ≥ 2
wideband CQISCell1 – wideband CQISCell2 ≥ 2
wideband CQISCell1 – wideband CQISCell3 ≥ 2
for more than 90% of the time.
Table 9.6.1.4-3: PUCCH 1-0 static test on multiple cells (TDD-FDD CA with TDD PCell, 3 and 4 DL CA)
Parameter |
Unit |
PCell |
SCell1 |
SCell2, SCell3 |
|
PDSCH transmission mode |
1 |
||||
Uplink downlink configuration |
2 |
2 for TDD Cell N/A for FDD Cell |
|||
Special subframe configuration |
4 |
4 for TDD Cell N/A for FDD Cell |
|||
Downlink power allocation |
|
dB |
0 |
||
|
dB |
0 |
|||
Propagation condition and antenna configuration |
AWGN (1 x 2) |
||||
SNR |
dB |
12 |
6 |
0 |
|
|
dB[mW/15kHz] |
-86 |
-92 |
-98 |
|
|
dB[mW/15kHz] |
-98 |
-98 |
-98 |
|
Physical channel for CQI reporting |
PUCCH Format 2 |
||||
PUCCH Report Type |
4 |
||||
Reporting periodicity |
ms |
Npd = 20 |
|||
cqi-pmi-ConfigurationIndex |
18 |
23 (shift of 5 ms relative to Pcell) |
28 for SCell 2 (shift of 10 ms relative to Pcell) , 33 for SCell 3 (shift of 15ms relative to PCell) |
||
Note 1: 3 symbols are allocated to PDCCH. No PDSCH for user data is scheduled for the UE with one sided dynamic OCNG Pattern OP.1 FDD and OP.1 TDD as described in Annex A.5.1.1 and A.5.2.1. Note 2: Void Note 3: Void |
Table 9.6.1.4-4: PUCCH 1-0 static test (TDD-FDD CA with TDD PCell, 3 DL CA)
Test number |
Bandwidth combination (MHz) |
1 |
2x20MHz for TDD cell and 20MHz for FDD cell |
2 |
2x20MHz for TDD cell and 15MHz for FDD cell |
3 |
2x20MHz for TDD cell and 10MHz for FDD cell |
4 |
2x20MHz for FDD cell and 20MHz for TDD cell |
5 |
20+15MHz for FDD cell and 20MHz for TDD cell |
6 |
20+10MHz for FDD cell and 20MHz for TDD cell |
7 |
2x10MHz for FDD cell and 20MHz for TDD cell |
8 |
10MHz for FDD cell and 15+20MHz for TDD cell |
9 |
10+15MHz for FDD cell and 20MHz for TDD cell |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2A. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: If more than one cell can be configured as PCell, choose one of the cells with the smallest bandwidth as PCell. Mapping of PCell and Scells to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
Table 9.6.1.4-5: PUCCH 1-0 static test (TDD-FDD CA with TDD PCell, 4 DL CA)
Test number |
Bandwidth combination (MHz) |
1 |
3x20MHz for TDD cell and 20MHz for FDD cell |
2 |
2x20MHz for FDD cell and 2x20MHz for TDD cell |
3 |
20+15MHz for FDD cell and 2x20MHz for TDD cell |
4 |
2x15MHz for FDD cell and 2x20MHz for TDD cell |
5 |
2×20+15MHz for FDD cell and 20MHz for TDD cell |
6 |
2×15+20MHz for FDD cell and 20MHz for TDD cell |
7 |
2×20+10MHz for FDD cell and 20MHz for TDD cell |
8 |
3x20MHz for FDD cell and 20MHz for TDD cell |
9 |
10MHz for FDD cell and 3x20MHz for TDD cell |
10 |
2x10MHz for FDD cell and 2x20MHz for TDD cell |
11 |
2x10MHz for FDD cell and 20+15MHz for TDD cell |
12 |
10+20MHz for FDD cell and 2x20MHz for TDD cell |
13 |
10+15MHz for FDD cell and 2x20MHz for TDD cell |
14 |
10+15+20MHz for FDD cell and 20MHz for TDD cell |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2A. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: If more than one cell can be configured as PCell, choose one of the cells with the smallest bandwidth as PCell. Mapping of PCell and Scells to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
The following requirements for 5DL CA apply to UE Category 8 and ≥11. For TDD-FDD CA with TDD PCell with 5 DL CC, for the parameters specified in Table 9.6.1.4-6 and Table 9.6.1.4-7, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell1 reported, and the difference between the wideband CQI indices of SCell1 and SCell2, SCell1 and SCell3 and SCell 1 and SCell 4 reported shall be such that
wideband CQIPCell – wideband CQISCell1 ≥ 2
wideband CQISCell1 – wideband CQISCell2 ≥ 2
wideband CQISCell1 – wideband CQISCell3 ≥ 2
wideband CQISCell1 – wideband CQISCell4 ≥ 2
for more than 90% of the time.
Table 9.6.1.4-6: PUCCH 1-0 static test on multiple cells (TDD-FDD CA with TDD PCell, 5 DL CA)
Parameter |
Unit |
PCell |
SCell1 |
SCell2, SCell3, SCell4 |
|
PDSCH transmission mode |
1 |
||||
Uplink downlink configuration |
2 |
2 if Scell1 is TDD Cell N/A if Scell1 is FDD Cell |
|||
Special subframe configuration |
4 |
4 if Scell1 is TDD Cell N/A if Scell1 is FDD Cell |
|||
Downlink power allocation |
|
dB |
0 |
||
|
dB |
0 |
|||
Propagation condition and antenna configuration |
AWGN (1 x 2) |
||||
SNR |
dB |
12 |
6 |
0 |
|
|
dB[mW/15kHz] |
-86 |
-92 |
-98 |
|
|
dB[mW/15kHz] |
-98 |
-98 |
-98 |
|
Physical channel for CQI reporting |
PUCCH Format 2 |
||||
PUCCH Report Type |
4 |
||||
Reporting periodicity |
ms |
Npd = 40 |
|||
cqi-pmi-ConfigurationIndex |
38 |
43 (shift of 5 ms relative to Pcell) |
48 for SCell 2 (shift of 10 ms relative to Pcell), 53 for SCell 3 (shift of 15 ms relative to Pcell), 58 for SCell 4 (shift of 20 ms relative to Pcell) |
||
Note 1: 3 symbols are allocated to PDCCH. No PDSCH for user data is scheduled for the UE with one sided dynamic OCNG Pattern OP.1 FDD and OP.1 TDD as described in Annex A.5.1.1 and A.5.2.1. Note 2: Void Note 3: Void |
Table 9.6.1.4-7: PUCCH 1-0 static test (TDD-FDD CA with TDD PCell, 5 DL CA)
Test number |
Bandwidth combination (MHz) |
1 |
15MHz+2×20MHz for FDD cell and 2x20MHz for TDD cell |
2 |
2×15MHz+20MHz for FDD cell and 2x20MHz for TDD cell |
3 |
4×20(FDD)+20(TDD)MHz |
4 |
3×20(FDD)+2×20(TDD)MHz |
5 |
2×20(FDD)+3×20(TDD)NA |
6 |
20(FDD)+4×20(TDD)MHz |
7 |
10(FDD)+4×20(TDD)MHz |
8 |
2×10(FDD)+3×20(TDD)MH |
9 |
10+20(FDD)+3×20(TDD)MHz |
10 |
10+2×20(FDD)+2×20(TDD)MHz |
11 |
10+15+20(FDD)+2×20(TDD)MHz |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2A. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: If more than one cell can be configured as PCell, choose one of the cells with the smallest bandwidth as PCell. Mapping of PCell and Scells to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
The following requirements for 6DL CA apply to UE Category 8 and ≥11. For TDD-FDD CA with TDD PCell with 6 DL CC, for the parameters specified in Table 9.6.1.4-8 and Table 9.6.1.4-9, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell1 reported, and the difference between the wideband CQI indices of SCell1 and SCell2, SCell1 and SCell3, SCell1 and SCell4, and SCell1 and SCell5 reported shall be such that
wideband CQIPCell – wideband CQISCell1 ≥ 2
wideband CQISCell1 – wideband CQISCell2 ≥ 2
wideband CQISCell1 – wideband CQISCell3 ≥ 2
wideband CQISCell1 – wideband CQISCell4 ≥ 2
wideband CQISCell1 – wideband CQISCell5 ≥ 2
for more than 90% of the time.
Table 9.6.1.4-8: PUCCH 1-0 static test on multiple cells (TDD-FDD CA with TDD PCell, 6 DL CA)
Parameter |
Unit |
PCell |
SCell1 |
SCell2, SCell3, SCell4, SCell5 |
|
PDSCH transmission mode |
1 |
||||
Uplink downlink configuration |
2 |
2 if Scell1 is TDD Cell N/A if Scell1 is FDD Cell |
|||
Special subframe configuration |
4 |
4 if Scell1 is TDD Cell N/A if Scell1 is FDD Cell |
|||
Downlink power allocation |
|
dB |
0 |
||
|
dB |
0 |
|||
Propagation condition and antenna configuration |
AWGN (1 x 2) |
||||
SNR |
dB |
12 |
6 |
0 |
|
|
dB[mW/15kHz] |
-86 |
-92 |
-98 |
|
|
dB[mW/15kHz] |
-98 |
-98 |
-98 |
|
Physical channel for CQI reporting |
PUCCH Format 2 |
||||
PUCCH Report Type |
4 |
||||
Reporting periodicity |
ms |
Npd = 40 |
|||
cqi-pmi-ConfigurationIndex |
38 |
43 (shift of 5 ms relative to Pcell) |
48 for SCell 2 (shift of 10 ms relative to Pcell), 53 for SCell 3 (shift of 15 ms relative to Pcell), 58 for SCell 4 (shift of 20 ms relative to Pcell), 63 for SCell 5 (shift of 25 ms relative to Pcell) |
||
Note 1: 3 symbols are allocated to PDCCH. No PDSCH for user data is scheduled for the UE with one sided dynamic OCNG Pattern OP.1 FDD and OP.1 TDD as described in Annex A.5.1.1 and A.5.2.1. Note 2: Void Note 3: Void |
Table 9.6.1.4-9: PUCCH 1-0 static test (TDD-FDD CA with TDD PCell, 6 DL CA)
Test number |
Bandwidth combination (MHz) |
1 |
1×20(FDD)+ 5×20(TDD)MHz |
2 |
2×20(FDD)+4×20(TDD)MHz |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2A. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: If more than one cell can be configured as PCell, choose one of the cells with the smallest bandwidth as PCell. Mapping of PCell and Scells to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |
The following requirements for 7DL CA apply to UE Category 8 and ≥11. For TDD-FDD CA with TDD PCell with 7 DL CC, for the parameters specified in Table 9.6.1.4-10 and Table 9.6.1.4-11, and using the downlink physical channels specified in tables C.3.2-1 and C.3.2-2 on each cell, the difference between the wideband CQI indices of PCell and SCell1 reported, and the difference between the wideband CQI indices of SCell1 and SCell2, SCell1 and SCell3, SCell1 and SCell4, SCell1 and SCell5, and SCell1 and SCell6 reported shall be such that
wideband CQIPCell – wideband CQISCell1 ≥ 2
wideband CQISCell1 – wideband CQISCell2 ≥ 2
wideband CQISCell1 – wideband CQISCell3 ≥ 2
wideband CQISCell1 – wideband CQISCell4 ≥ 2
wideband CQISCell1 – wideband CQISCell5 ≥ 2
wideband CQISCell1 – wideband CQISCell6 ≥ 2
for more than 90% of the time.
Table 9.6.1.4-10: PUCCH 1-0 static test on multiple cells (TDD-FDD CA with TDD PCell, 7 DL CA)
Parameter |
Unit |
PCell |
SCell1 |
SCell2, SCell3, SCell4, SCell5 |
|
PDSCH transmission mode |
1 |
||||
Uplink downlink configuration |
2 |
2 if Scell1 is TDD Cell N/A if Scell1 is FDD Cell |
|||
Special subframe configuration |
4 |
4 if Scell1 is TDD Cell N/A if Scell1 is FDD Cell |
|||
Downlink power allocation |
|
dB |
0 |
||
|
dB |
0 |
|||
Propagation condition and antenna configuration |
AWGN (1 x 2) |
||||
SNR |
dB |
12 |
6 |
0 |
|
|
dB[mW/15kHz] |
-86 |
-92 |
-98 |
|
|
dB[mW/15kHz] |
-98 |
-98 |
-98 |
|
Physical channel for CQI reporting |
PUCCH Format 2 |
||||
PUCCH Report Type |
4 |
||||
Reporting periodicity |
ms |
Npd = 40 |
|||
cqi-pmi-ConfigurationIndex |
38 |
43 (shift of 5 ms relative to Pcell) |
48 for SCell 2 (shift of 10 ms relative to Pcell), 53 for SCell 3 (shift of 15 ms relative to Pcell), 58 for SCell 4 (shift of 20 ms relative to Pcell), 63 for SCell 5 (shift of 25 ms relative to Pcell), 68 for SCell 5 (shift of 30 ms relative to Pcell) |
||
Note 1: 3 symbols are allocated to PDCCH. No PDSCH for user data is scheduled for the UE with one sided dynamic OCNG Pattern OP.1 FDD and OP.1 TDD as described in Annex A.5.1.1 and A.5.2.1. Note 2: Void Note 3: Void |
Table 9.6.1.4-11: PUCCH 1-0 static test (TDD-FDD CA with TDD PCell, 7 DL CA)
Test number |
Bandwidth combination (MHz) |
1 |
1×20(FDD)+ 6×20(TDD)MHz |
2 |
2×20(FDD)+5×20(TDD)MHz |
Note 1: The applicability of requirements for different CA configurations and bandwidth combination sets is defined in 9.1.1.2A. The test coverage for different number of component carriers is defined in 9.1.1.3. Note 2: If more than one cell can be configured as PCell, choose one of the cells with the smallest bandwidth as PCell. Mapping of PCell and Scells to the CCs shall be constant for all the iterations during the test. Each execution of the test shall use the same mapping. |