8.7.5 TDD FDD CA
36.1013GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Release 18TSUser Equipment (UE) radio transmission and reception
The parameters specified in Table 8.7.5-1 are valid for all TDD FDD CA tests unless otherwise stated.
Table 8.7.5-1: Common Test Parameters (TDD FDD CA)
Parameter |
Unit |
Value |
||||
Uplink downlink configuration (Note 1) for TDD CC |
1 |
|||||
Special subframe configuration (Note 2) for TDD CC |
4 |
|||||
Downlink power allocation |
|
dB |
-3 |
|||
|
dB |
-3 |
||||
σ |
dB |
0 |
||||
Cyclic prefix |
Normal |
|||||
Cell ID |
0 |
|||||
Inter-TTI Distance |
1 |
|||||
Maximum number of HARQ processes per component carrier |
FDD PCell |
Processes |
8 for FDD and TDD CCs |
|||
TDD PCell |
Processes |
11 for FDD CC; 7 for TDD CC |
||||
Maximum number of HARQ transmission |
4 |
|||||
Redundancy version coding sequence |
{0,0,1,2} for 64QAM, 256QAM |
|||||
Number of OFDM symbols for PDCCH per component carrier |
OFDM symbols |
1 |
||||
Cross carrier scheduling |
Not configured |
|||||
Propagation condition |
Static propagation condition No external noise sources are applied |
|||||
Transmission mode |
TM3 |
|||||
Codebook subset restriction |
10 |
|||||
Antenna configuration |
2 x 2 |
|||||
at antenna port (dBm/15kHz) |
-85 |
|||||
Symbols for unused PRBs |
OP.1 FDD for FDD CC, OP.1 TDD for TDD CC |
|||||
ACK/NACK feedback mode |
PUCCH format 3 |
|||||
Downlink HARQ-ACK timing |
FDD PCell |
As specified in Clause 7.3.3 in TS36.213 [6] |
||||
TDD PCell |
As specified in Clause 7.3.4 in TS36.213 [6] |
|||||
Note 1: as specified in Table 4.2-2 in TS 36.211 [4]. Note 2: as specified in Table 4.2-1 in TS 36.211 [4]. |
8.7.5.1 Minimum Requirement FDD PCell
For UE not supporting 256QAM, the requirements for TDD FDD CA with FDD PCell are specified in Table 8.7.5.1-1 with the additional parameters specified in Table 8.7.5-1, and the downlink physical channel setup according to Annex C.3.2. The test points are applied to UE category and bandwidth combination with maximum aggregated bandwidth as specified inTable 8.7.5.1-2. The TB success rate shall be sustained during at least 300 frames.
For UE supporting 256QAM, the requirements for TDD FDD CA with FDD PCell are specified in Table 8.7.5.1-3 with the additional parameters specified in Table 8.7.5-1, and the downlink physical channel setup according to Annex C.3.2. The test points are applied to UE category or UE DL category, and bandwidth combination with the maximum aggregated bandwidth as specified in Table 8.7.5.1-4. The TB success rate shall be sustained during at least 300 frames. For UE supporting 256QAM, the requirement in Table 8.7.5.1-1 is not applicable.
The applicability of the requirements are specified in Clause 8.1.2.3B. The test coverage for different number of component carriers is defined in 8.1.2.4.
Table 8.7.5.1-1: test parameters for sustained downlink data rate (TDD FDD CA 64QAM)
Test number |
Bandwidth (MHz) |
Number of bits of a DL-SCH transport block received within a TTI (for normal/special subframe for TDD, except for subframe #5) |
Measurement channel |
Reference value |
||||
Total |
FDD CC |
TDD CC |
FDD CC |
TDD CC |
FDD CC |
TDD CC |
TB success rate [%] |
|
1 |
2×20 |
20 |
20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
2 |
10+20 |
10 |
20 |
36696 |
75376/0 |
R.31-3A FDD |
R.31-4 TDD |
85 |
2A |
15+20 |
15 |
20 |
55056 |
75376/0 |
R.31-5 FDD |
R.31-4 TDD |
85 |
3 |
10+10 |
10 |
10 |
36696 |
36696/0 |
R.31-3A FDD |
R.31-6 TDD |
85 |
4 |
3×20 |
20 |
2×20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
5 |
15+20+20 |
15 |
2×20 |
55056 |
75376/0 |
R.31-5 FDD |
R.31-4 TDD |
85 |
6 |
10+20+20 |
10 |
2×20 |
36696 |
75376/0 |
R.31-3A FDD |
R.31-4 TDD |
85 |
7 |
3×20 |
2×20 |
20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
8 |
20+20+15 |
20+15 |
20 |
75376 for 20MHz CC 55056 for 15MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-5 FDD for 15MHz CC |
R.31-4 TDD |
85 |
9 |
20+20+10 |
20+10 |
20 |
75376 for 20MHz CC 36696 for 10MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-3A FDD for 10MHz CC |
R.31-4 TDD |
85 |
9A |
20+10+10 |
2×10 |
20 |
36696 |
75376/0 |
R.31-3A |
R.31-4 TDD |
85 |
9B |
10+15+20 |
10 |
15+20 |
36696 |
75376/0 for 20MHz CC 55056/0 for 15MHz CC |
R.31-3A FDD |
R.31-5 TDD for 15MHz CC R.31-4 TDD for 20MHz CC |
85 |
9C |
10+15+20 |
10+15 |
20 |
36696 for 10MHz CC 55056 for 15MHz CC |
75376/0 |
R.31-3A FDD for 10MHz CC R.31-5 FDD for 15MHz CC |
R.31-4 TDD |
85 |
10 |
4×20 |
20 |
3×20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
11 |
4×20 |
2×20 |
2×20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
12 |
3×20+15 |
20+15 |
2×20 |
75376 for 20MHz CC 55056 for 15MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-5 FDD for 15MHz CC |
R.31-4 TDD |
85 |
13 |
2×15+2×20 |
2×15 |
2×20 |
55056 |
75376/0 |
R.31-5 FDD |
R.31-4 TDD |
85 |
14 |
3×20+15 |
2×20+15 |
20 |
75376 for 20MHz CC 55056 for 15MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-5 FDD for 15MHz CC |
R.31-4 TDD |
85 |
15 |
2×15+2×20 |
2×15+20 |
20 |
75376 for 20MHz CC 55056 for 15MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-5 FDD for 15MHz CC |
R.31-4 TDD |
85 |
15A |
3×20+10 |
2×20+10 |
20 |
75376 for 20MHz CC 36696 for 10MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-3A FDD for 10MHz CC |
R.31-4 TDD |
85 |
15B |
4×20 |
3×20 |
20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
15C |
10+3×20 |
10 |
3×20 |
36696 |
75376/0 |
R.31-3A FDD |
R.31-4 TDD |
85 |
15D |
2×10+2×20 |
2×10 |
2×20 |
36696 |
75376/0 |
R.31-3A FDD |
R.31-4 TDD |
85 |
15E |
2×10+20+15 |
2×10 |
20+15 |
36696 |
75376/0 for 20MHz CC 55056/0 for 15MHz CC |
R.31-3A FDD |
R.31-5 TDD for 15MHz CC R.31-4 TDD for 20MHz CC |
85 |
15F |
10+3×20 |
10+20 |
2×20 |
75376 for 20MHz CC 36696 for 10MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-3A FDD for 10MHz CC |
R.31-4 TDD |
85 |
15G |
10+15+2×20 |
10+15 |
2×20 |
36696 for 10MHz CC 55056 for 15MHz CC |
75376/0 |
R.31-3A FDD for 10MHz CC R.31-5 FDD for 15MHz CC |
R.31-4 TDD |
85 |
15H |
10+15+2×20 |
10+15+20 |
20 |
36696 for 10MHz CC 55056 for 15MHz CC 75376 for 20MHz CC |
75376/0 |
R.31-3A FDD for 10MHz CC R.31-5 FDD for 15MHz CC R.31-4 FDD for 20MHz CC |
R.31-4 TDD |
85 |
16 |
4×20+15 |
2×20+15 |
2×20 |
75376 for 20MHz CC 55056 for 15MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-5 FDD for 15MHz CC |
R.31-4 TDD |
85 |
17 |
2×15+3×20 |
2×15+20 |
2×20 |
75376 for 20MHz CC 55056 for 15MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-5 FDD for 15MHz CC |
R.31-4 TDD |
85 |
18 |
4×20+20 |
4×20 |
20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
19 |
3×20+2×20 |
3×20 |
2×20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
20 |
2×20+3×20 |
2×20 |
3×20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
21 |
20+4×20 |
20 |
4×20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
22 |
10+4×20 |
10 |
4×20 |
36696 for 10MHz CC |
75376/0 |
R.31-3A FDD for 10MHz CC |
R.31-4 TDD |
85 |
23 |
10+20+3×20 |
10+20 |
3×20 |
36696 for 10MHz CC 75376 for 20MHz CC |
75376/0 |
R.31-3A FDD for 10MHz CC, R.31-4 FDD for 20MHz CC |
R.31-4 TDD |
85 |
24 |
2×10+3×20 |
2×10 |
3×20 |
36696 for 10MHz CC |
75376/0 |
R.31-3A FDD for 10MHz CC |
R.31-4 TDD |
85 |
25 |
10+2×20+2×20 |
10+2×20 |
2×20 |
36696 for 10MHz CC 75376 for 20MHz CC |
75376/0 |
R.31-3A FDD for 10MHz CC, R.31-4 FDD for 20MHz CC |
R.31-4 TDD |
85 |
26 |
10+15+20+2×20 |
10+15+20 |
2×20 |
36696 for 10MHz CC 55056 for 15MHz CC 75376 for 20MHz CC |
75376/0 |
R.31-3A FDD for 10MHz CC R.31-5 FDD for 15MHz CC R.31-4 FDD for 20MHz CC, |
R.31-4 TDD |
85 |
27 |
20+5×20 |
20 |
5×20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
28 |
2×20+4×20 |
2×20 |
4×20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
29 |
20+6×20 |
20 |
6×20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
30 |
2×20+5×20 |
2×20 |
5×20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
Table 8.7.5.1-2: Test points for sustained data rate (FRC 64QAM)
CA config |
Maximum supported Bandwidth/ Bandwidth combination (MHz) |
Cat. 1 |
Cat. 2 |
Cat. 3 |
Cat. 4 |
Cat. 6, 7 |
Cat. 9,10 |
Cat 11, 12 |
DL Cat. 15 |
||
Total |
FDD CC |
TDD CC |
DL Cat. 6, 7 |
DL Cat. 9, 10 |
DL Cat. 11, 12 |
||||||
CA with 2CCs |
2×20 |
20 |
20 |
– |
– |
3 |
3 |
1 |
1 |
– |
– |
10+20 |
10 |
20 |
– |
– |
3 |
3 |
2 |
2 |
– |
– |
|
15+20 |
15 |
20 |
– |
– |
3 |
3 |
2A |
2A |
– |
– |
|
10+10 |
10 |
10 |
– |
– |
3 |
3 |
3 |
3 |
– |
– |
|
CA with 3CCs |
3×20 |
20 |
2×20 |
– |
– |
– |
– |
1 |
4 |
4 |
– |
15+20+20 |
15 |
2×20 |
– |
– |
– |
– |
2A |
5 |
5 |
– |
|
10+20+20 |
10 |
2×20 |
– |
– |
– |
– |
2 |
6 |
6 |
– |
|
3×20 |
2×20 |
20 |
– |
– |
– |
– |
1 |
7 |
7 |
– |
|
20+20+15 |
20+15 |
20 |
– |
– |
– |
– |
1 |
8 |
8 |
– |
|
20+20+10 |
20+10 |
20 |
– |
– |
– |
– |
1 |
9 |
9 |
– |
|
20+10+10 |
2×10 |
20 |
– |
– |
– |
– |
2 |
9A |
9A |
– |
|
10+15+20 |
10 |
15+20 |
2 |
9B |
9B |
||||||
10+15+20 |
10+15 |
20 |
2A |
9C |
9C |
||||||
CA with 4CCs |
4×20 |
20 |
3×20 |
– |
– |
– |
– |
– |
4 |
10 |
10 |
4×20 |
2×20 |
2×20 |
– |
– |
– |
– |
– |
4 or 7 |
11 |
11 |
|
3×20+15 |
20+15 |
2×20 |
– |
– |
– |
– |
– |
4 |
12 |
12 |
|
2×15+2×20 |
2×15 |
2×20 |
– |
– |
– |
– |
– |
5 |
13 |
13 |
|
3×20+15 |
2×20+15 |
20 |
– |
– |
– |
– |
– |
7 |
14 |
14 |
|
2×15+2×20 |
2×15+20 |
20 |
– |
– |
– |
– |
– |
8 |
15 |
15 |
|
3×20+10 |
2×20+10 |
20 |
– |
– |
– |
– |
– |
7 |
15A |
15A |
|
4×20 |
2×15+20 |
20 |
– |
– |
– |
– |
– |
8 |
15B |
15B |
|
10+3×20 |
10 |
3×20 |
6 |
15C |
15C |
||||||
2×10+2×20 |
2×10 |
2×20 |
6 |
15D |
15D |
||||||
2×10+20+15 |
2×10 |
20+15 |
9A |
15E |
15E |
||||||
10+3×20 |
10+20 |
2×20 |
4 |
15F |
15F |
||||||
10+15+2×20 |
10+15 |
2×20 |
5 |
15G |
15G |
||||||
10+15+2×20 |
10+15+20 |
20 |
8 |
15H |
15H |
||||||
CA with 5 CCs |
4×20+15 |
2×20+15 |
2×20 |
– |
– |
– |
– |
– |
– |
11 |
16 |
2×15+3×20 |
2×15+20 |
2×20 |
– |
– |
– |
– |
– |
– |
12 |
17 |
|
4×20+20 |
4×20 |
20 |
18 |
||||||||
3×20+2×20 |
3×20 |
2×20 |
19 |
||||||||
2×20+3×20 |
2×20 |
3×20 |
20 |
||||||||
20+4×20 |
20 |
4×20 |
21 |
||||||||
10+4×20 |
10 |
4×20 |
22 |
||||||||
10+20+3×20 |
10+20 |
3×20 |
23 |
||||||||
2×10+3×20 |
2×10 |
3×20 |
24 |
||||||||
10+2×20+2×20 |
10+2×20 |
2×20 |
25 |
||||||||
10+15+20+2×20 |
10+15+20 |
2×20 |
26 |
||||||||
CA with 6 CCs |
20+5×20 |
20 |
5×20 |
27 |
27 |
||||||
2×20+4×20 |
2×20 |
4×20 |
28 |
28 |
|||||||
CA with 7 CCs |
20+6×20 |
20 |
6×20 |
29 |
29 |
||||||
2×20+5×20 |
2×20 |
5×20 |
30 |
30 |
|||||||
Note 1: Void. Note 2: Void. Note 3: If DL category is signalled by the UE under test, then select the test point according to UE DL Category. Otherwise, select the test point according to the UE category signalled. |
Table 8.7.5.1-3: Minimum requirement (TDD FDD CA 256QAM)
Test number |
Bandwidth (MHz) |
Measurement channel |
Reference value |
||||
Total |
FDD CC |
TDD CC |
FDD CC |
TDD CC |
TB success rate [%] |
||
1 |
2×20 |
20 |
20 |
R.68 FDD |
R.68 TDD |
85 |
|
2 |
10+20 |
10 |
20 |
R.68-2 FDD |
R.68 TDD |
85 |
|
3 |
15+20 |
15 |
20 |
R.68-1 FDD |
R.68 TDD |
85 |
|
4 |
3×20 |
20 |
2×20 |
R.68 FDD |
R.68 TDD |
85 |
|
5 |
15+20+20 |
15 |
2×20 |
R.68-1 FDD |
R.68 TDD |
85 |
|
6 |
10+20+20 |
10 |
2×20 |
R.68-2 FDD |
R.68TDD |
85 |
|
7 |
3×20 |
2×20 |
20 |
R.68 FDD |
R.68 TDD |
85 |
|
8 |
20+20+15 |
20+15 |
20 |
R.68 FDD for 20MHz CC, R.68-1 FDD for 15MHz CC |
R.68 TDD |
85 |
|
9 |
20+20+10 |
20+10 |
20 |
R.68 FDD for 20MHz CC, R.68-2 FDD for 10MHz CC |
R.68 TDD |
85 |
|
9A |
20+10+10 |
2×10 |
20 |
R.68-2 FDD |
R.68 TDD |
85 |
|
9B |
10+15+20 |
10 |
15+20 |
R.68-2 FDD |
R.68-1 TDD for 15MHz CC R.68 TDD for 20MHz CC |
85 |
|
9C |
10+15+20 |
10+15 |
20 |
R.68-2 FDD for 10MHz CC, R.68-1 FDD for 15MHz CC |
R.68 TDD |
85 |
|
10 |
4×20 |
20 |
3×20 |
R.68-2 FDD |
R.68TDD |
85 |
|
11 |
4×20 |
2×20 |
2×20 |
R.68 FDD |
R.68 TDD |
85 |
|
12 |
3×20+15 |
20+15 |
2×20 |
R.68 FDD for 20MHz CC, R.68-1 FDD for 15MHz CC |
R.68 TDD |
85 |
|
13 |
2×15+2×20 |
2×15 |
2×20 |
R.68-1 FDD |
R.68 TDD |
85 |
|
14 |
3×20+15 |
2×20+15 |
20 |
R.68 FDD for 20MHz CC, R.68-1 FDD for 15MHz CC |
R.68 TDD |
85 |
|
15 |
2×15+2×20 |
2×15+20 |
20 |
R.68 FDD for 20MHz CC, R.68-1 FDD for 15MHz CC |
R.68 TDD |
85 |
|
15A |
3×20+10 |
2×20+10 |
20 |
R.68 FDD for 20MHz CC, R.68-2 FDD for 10MHz CC |
R.68 TDD |
85 |
|
15B |
4×20 |
3×20 |
20 |
R.68 FDD |
R.68TDD |
85 |
|
15C |
10+3×20 |
10 |
3×20 |
R.68-2 FDD |
R.68TDD |
85 |
|
15D |
2×10+2×20 |
2×10 |
2×20 |
R.68-2 FDD |
R.68TDD |
85 |
|
15E |
2×10+20+15 |
2×10 |
20+15 |
R.68-2 FDD |
R.68-1 TDD for 15MHz CC R.68 TDD for 20MHz CC |
85 |
|
15F |
10+3×20 |
10+20 |
2×20 |
R.68 FDD for 20MHz CC, R.68-2 FDD for 10MHz CC |
R.68 TDD |
85 |
|
15G |
10+15+2×20 |
10+15 |
2×20 |
R.68-2 FDD for 10MHz CC, R.68-1 FDD for 15MHz CC |
R.68 TDD |
85 |
|
15H |
10+15+2×20 |
10+15+20 |
20 |
R.68-2 FDD for 10MHz CC, R.68-1 FDD for 15MHz CC, R.68 FDD for 20MHz CC |
R.68 TDD |
85 |
|
16 |
4×20+15 |
2×20+15 |
2×20 |
R.68 FDD for 20MHz CC, R.68-1 FDD for 15MHz CC |
R.68 TDD |
85 |
|
17 |
2×15+3×20 |
2×15+20 |
2×20 |
R.68 FDD for 20MHz CC, R.68-1 FDD for 15MHz CC |
R.68 TDD |
85 |
|
18 |
4×20+20 |
4×20 |
20 |
R.68 FDD |
R.68TDD |
85 |
|
19 |
3×20+2×20 |
3×20 |
2×20 |
R.68 FDD |
R.68 TDD |
85 |
|
20 |
2×20+3×20 |
2×20 |
3×20 |
R.68 FDD |
R.68TDD |
85 |
|
21 |
20+4×20 |
20 |
4×20 |
R.68 FDD |
R.68 TDD |
85 |
|
22 |
10+4×20 |
10 |
4×20 |
R.68-2 FDD |
R.68 TDD |
85 |
|
23 |
10+20+3×20 |
10+20 |
3×20 |
R.68 FDD for 20MHz CC, R.68-2 FDD for 10MHz CC |
R.68 TDD |
85 |
|
24 |
2×10+3×20 |
2×10 |
3×20 |
R.68-2 FDD |
R.68 TDD |
85 |
|
25 |
10+2×20+2×20 |
10+2×20 |
2×20 |
R.68 FDD for 20MHz CC, R.68-2 FDD for 10MHz CC |
R.68 TDD |
85 |
|
26 |
10+15+20+2×20 |
10+15+20 |
2×20 |
R.68-2 FDD for 10MHz CC, R.68-1 FDD for 15MHz CC, R.68 FDD for 20MHz CC |
R.68 TDD |
85 |
|
27 |
20+5×20 |
20 |
5×20 |
R.68-2 FDD |
R.68 TDD |
85 |
|
28 |
2×20+4×20 |
2×20 |
4×20 |
R.68-2 FDD |
R.68 TDD |
85 |
|
29 |
20+6×20 |
20 |
6×20 |
R.68-2 FDD |
R.68 TDD |
85 |
|
30 |
2×20+5×20 |
2×20 |
5×20 |
R.68-2 FDD |
R.68 TDD |
85 |
Table 8.7.5.1-4: Test points for sustained data rate (FRC 256QAM)
CA config |
Maximum supported Bandwidth/ Bandwidth combination (MHz) |
Cat. 11, 12 |
DL Cat. 13 |
DL Cat. 15 |
DL Cat. 16 |
||||
Total |
FDD CC |
TDD CC |
DL Cat. 11, 12 |
||||||
CA with 2CCs |
2×20 |
20 |
20 |
1 |
1 |
– |
– |
||
10+20 |
10 |
20 |
2 |
2 |
|||||
15+20 |
15 |
20 |
3 |
3 |
– |
– |
|||
CA with 3CCs |
3×20 |
20 |
2×20 |
4 |
1 |
4 |
– |
||
15+20+20 |
15 |
2×20 |
5 |
3 |
5 |
– |
|||
10+20+20 |
10 |
2×20 |
6 |
2 |
6 |
– |
|||
3×20 |
2×20 |
20 |
7 |
1 |
7 |
– |
|||
20+20+15 |
20+15 |
20 |
8 |
1 |
8 |
– |
|||
20+20+10 |
20+10 |
20 |
9 |
1 |
9 |
– |
|||
20+10+10 |
2×10 |
20 |
9A |
2 |
9A |
||||
10+15+20 |
10 |
15+20 |
9B |
2 |
9B |
||||
10+15+20 |
10+15 |
20 |
9C |
3 |
9C |
||||
CA with 4CCs |
4×20 |
20 |
3×20 |
4 |
– |
10 |
10 |
||
4×20 |
2×20 |
2×20 |
4 or 7 |
– |
11 |
11 |
|||
3×20+15 |
20+15 |
2×20 |
8 |
– |
12 |
12 |
|||
2×15+2×20 |
2×15 |
2×20 |
5 |
– |
13 |
13 |
|||
3×20+15 |
2×20+15 |
20 |
7 |
– |
14 |
14 |
|||
2×15+2×20 |
2×15+20 |
20 |
8 |
– |
15 |
15 |
|||
3×20+10 |
2×20+10 |
20 |
7 |
– |
15A |
15A |
|||
4×20 |
2×15+20 |
20 |
8 |
– |
15B |
15B |
|||
10+3×20 |
10 |
3×20 |
6 |
15C |
15C |
||||
2×10+2×20 |
2×10 |
2×20 |
6 |
15D |
15D |
||||
2×10+20+15 |
2×10 |
20+15 |
9A |
15E |
15E |
||||
10+3×20 |
10+20 |
2×20 |
4 |
15F |
15F |
||||
10+15+2×20 |
10+15 |
2×20 |
5 |
15G |
15G |
||||
10+15+2×20 |
10+15+20 |
20 |
8 |
15H |
15H |
||||
CA with 5CCs |
4×20+15 |
2×20+15 |
2×20 |
– |
– |
14 or 12 |
16 |
||
2×15+3×20 |
2×15+20 |
2×20 |
– |
– |
15 or 12 |
17 |
|||
4×20+20 |
4×20 |
20 |
18 |
||||||
3×20+2×20 |
3×20 |
2×20 |
19 |
||||||
2×20+3×20 |
2×20 |
3×20 |
20 |
||||||
20+4×20 |
20 |
4×20 |
21 |
||||||
10+4×20 |
10 |
4×20 |
22 |
||||||
10+20+3×20 |
10+20 |
3×20 |
23 |
||||||
2×10+3×20 |
2×10 |
3×20 |
24 |
||||||
10+2×20+2×20 |
10+2×20 |
2×20 |
25 |
||||||
10+15+20+2×20 |
10+15+20 |
2×20 |
26 |
||||||
CA with 6CCs |
20+5×20 |
20 |
5×20 |
27 |
|||||
2×20+4×20 |
2×20 |
4×20 |
28 |
||||||
CA with 7CCs |
20+6×20 |
20 |
6×20 |
29 |
|||||
2×20+5×20 |
2×20 |
5×20 |
30 |
||||||
Note 1: If DL category is signalled by the UE under test, then select the test point according to UE DL Category. Otherwise, select the test point according to the UE category signalled. |
8.7.5.2 Minimum Requirement TDD PCell
For UE not supporting 256QAM, the requirements for TDD FDD CA with TDD PCell are specified in Table 8.7.5.2-1 with the additional parameters specified in Table 8.7.5-1, and the downlink physical channel setup according to Annex C.3.2. The test points are applied to UE category and bandwidth combination with maximum aggregated bandwidth as specified inTable 8.7.5.2-2. The TB success rate shall be sustained during at least 300 frames.
For UE supporting 256QAM, the requirements for TDD FDD CA with FDD PCell are specified in Table 8.7.5.2-3 with the additional parameters specified in Table 8.7.5-1, and the downlink physical channel setup according to Annex C.3.2. The test points are applied to UE category or UE DL category, and bandwidth combination with maximum aggregated bandwidth as specified in Table 8.7.5.2-4. The TB success rate shall be sustained during at least 300 frames. For UE supporting 256QAM, the requirements in Table 8.7.5.2-1 is not applicable.
The applicability of ther requirements are specified in Clause 8.1.2.3B. The test coverage for different number of component carriers is defined in 8.1.2.4.
Table 8.7.5.2-1: test parameters for sustained downlink data rate (TDD FDD CA 64QAM)
Test number |
Bandwidth (MHz) |
Number of bits of a DL-SCH transport block received within a TTI (for normal/special subframe for TDD, except for subframe #5) |
Measurement channel |
Reference value |
||||
Total |
FDD CC |
TDD CC |
FDD CC |
TDD CC |
FDD CC |
TDD CC |
TB success rate [%] |
|
1 |
2×20 |
20 |
20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
2 |
10+20 |
10 |
20 |
36696 |
75376/0 |
R.31-3A FDD |
R.31-4 TDD |
85 |
2A |
15+20 |
15 |
20 |
55056 |
75376/0 |
R.31-5 FDD |
R.31-4 TDD |
85 |
3 |
10+10 |
10 |
10 |
36696 |
36696/0 |
R.31-3A FDD |
R.31-6 TDD |
85 |
4 |
3×20 |
20 |
2×20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
5 |
15+20+20 |
15 |
2×20 |
55056 |
75376/0 |
R.31-5 FDD |
R.31-4 TDD |
85 |
6 |
10+20+20 |
10 |
2×20 |
36696 |
75376/0 |
R.31-3A FDD |
R.31-4 TDD |
85 |
7 |
3×20 |
2×20 |
20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
8 |
20+20+15 |
20+15 |
20 |
75376 for 20MHz CC 55056 for 15MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-5 FDD for 15MHz CC |
R.31-4 TDD |
85 |
9 |
20+20+10 |
20+10 |
20 |
75376 for 20MHz CC 36696 for 10MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-3A FDD for 10MHz CC |
R.31-4 TDD |
85 |
9A |
20+10+10 |
2×10 |
20 |
36696 |
75376/0 |
R.31-3A |
R.31-4 TDD |
85 |
9B |
10+15+20 |
10 |
15+20 |
36696 |
75376/0 for 20MHz CC 55056/0 for 15MHz CC |
R.31-3A FDD |
R.31-5 TDD for 15MHz CC R.31-4 TDD for 20MHz CC |
85 |
9C |
10+15+20 |
10+15 |
20 |
36696 for 10MHz CC 55056 for 15MHz CC |
75376/0 |
R.31-3A FDD for 10MHz CC R.31-5 FDD for 15MHz CC |
R.31-4 TDD |
85 |
10 |
4×20 |
20 |
3×20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
11 |
4×20 |
2×20 |
2×20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
12 |
3×20+15 |
20+15 |
2×20 |
75376 for 20MHz CC 55056 for 15MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-5 FDD for 15MHz CC |
R.31-4 TDD |
85 |
13 |
2×15+2×20 |
2×15 |
2×20 |
55056 |
75376/0 |
R.31-5 FDD |
R.31-4 TDD |
85 |
14 |
3×20+15 |
2×20+15 |
20 |
75376 for 20MHz CC 55056 for 15MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-5 FDD for 15MHz CC |
R.31-4 TDD |
85 |
15 |
2×15+2×20 |
2×15+20 |
20 |
75376 for 20MHz CC 55056 for 15MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-5 FDD for 15MHz CC |
R.31-4 TDD |
85 |
15A |
3×20+10 |
2×20+10 |
20 |
75376 for 20MHz CC 36696 for 10MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-3A FDD for 10MHz CC |
R.31-4 TDD |
85 |
15B |
4×20 |
3×20 |
20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
15C |
10+3×20 |
10 |
3×20 |
36696 |
75376/0 |
R.31-3A FDD |
R.31-4 TDD |
85 |
15D |
2×10+2×20 |
2×10 |
2×20 |
36696 |
75376/0 |
R.31-3A FDD |
R.31-4 TDD |
85 |
15E |
2×10+20+15 |
2×10 |
20+15 |
36696 |
75376/0 for 20MHz CC 55056/0 for 15MHz CC |
R.31-3A FDD |
R.31-5 TDD for 15MHz CC R.31-4 TDD for 20MHz CC |
85 |
15F |
10+3×20 |
10+20 |
2×20 |
75376 for 20MHz CC 36696 for 10MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-3A FDD for 10MHz CC |
R.31-4 TDD |
85 |
15G |
10+15+2×20 |
10+15 |
2×20 |
36696 for 10MHz CC 55056 for 15MHz CC |
75376/0 |
R.31-3A FDD for 10MHz CC R.31-5 FDD for 15MHz CC |
R.31-4 TDD |
85 |
15H |
10+15+2×20 |
10+15+20 |
20 |
36696 for 10MHz CC 55056 for 15MHz CC 75376 for 20MHz CC |
75376/0 |
R.31-3A FDD for 10MHz CC R.31-5 FDD for 15MHz CC R.31-4 FDD for 20MHz CC |
R.31-4 TDD |
85 |
16 |
4×20+15 |
2×20+15 |
2×20 |
75376 for 20MHz CC 55056 for 15MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-5 FDD for 15MHz CC |
R.31-4 TDD |
85 |
17 |
2×15+3×20 |
2×15+20 |
2×20 |
75376 for 20MHz CC 55056 for 15MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-5 FDD for 15MHz CC |
R.31-4 TDD |
85 |
18 |
4×20+20 |
4×20 |
20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
19 |
3×20+2×20 |
3×20 |
2×20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
20 |
2×20+3×20 |
2×20 |
3×20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
21 |
20+4×20 |
20 |
4×20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
22 |
10+4×20 |
10 |
4×20 |
36696 |
75376/0 |
R.31-3A FDD |
R.31-4 TDD |
85 |
23 |
10+20+3×20 |
10+20 |
3×20 |
75376 for 20MHz CC 36696 for 10MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-3A FDD for 10MHz CC |
R.31-4 TDD |
85 |
24 |
2×10+3×20 |
2×10 |
3×20 |
36696 |
75376/0 |
R.31-3A FDD |
R.31-4 TDD |
85 |
25 |
10+2×20+2×20 |
10+2×20 |
2×20 |
75376 for 20MHz CC 36696 for 10MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-3A FDD for 10MHz CC |
R.31-4 TDD |
85 |
26 |
10+15+20+2×20 |
10+15+20 |
2×20 |
75376 for 20MHz CC 55056 for 15MHz CC 36696 for 10MHz CC |
75376/0 |
R.31-4 FDD for 20MHz CC, R.31-5 FDD for 15MHz CC, R.31-3A FDD for 10MHz CC |
R.31-4 TDD |
85 |
27 |
20+5×20 |
20 |
5×20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
28 |
2×20+4×20 |
2×20 |
4×20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
29 |
20+6×20 |
20 |
6×20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
30 |
2×20+5×20 |
2×20 |
5×20 |
75376 |
75376/0 |
R.31-4 FDD |
R.31-4 TDD |
85 |
Table 8.7.5.2-2: Test points for sustained data rate (FRC 64QAM)
CA config |
Maximum supported Bandwidth/ Bandwidth combination (MHz) |
Cat. 1 |
Cat. 2 |
Cat. 3 |
Cat. 4 |
Cat. 6, 7 |
Cat. 9,10 |
Cat 11, 12 |
DL Cat. 15 |
||
Total |
FDD CC |
TDD CC |
DL Cat. 6, 7 |
DL Cat. 9, 10 |
DL Cat. 11, 12 |
||||||
CA with 2CCs |
2×20 |
20 |
20 |
– |
– |
3 |
3 |
1 |
1 |
– |
– |
10+20 |
10 |
20 |
– |
– |
3 |
3 |
2 |
2 |
– |
– |
|
15+20 |
15 |
20 |
– |
– |
3 |
3 |
2A |
2A |
– |
– |
|
10+10 |
10 |
10 |
– |
– |
3 |
3 |
3 |
3 |
– |
– |
|
CA with 3CCs |
3×20 |
20 |
2×20 |
– |
– |
– |
– |
1 |
4 |
4 |
– |
15+20+20 |
15 |
2×20 |
– |
– |
– |
– |
2A |
5 |
5 |
– |
|
10+20+20 |
10 |
2×20 |
– |
– |
– |
– |
2 |
6 |
6 |
– |
|
3×20 |
2×20 |
20 |
– |
– |
– |
– |
1 |
7 |
7 |
– |
|
20+20+15 |
20+15 |
20 |
– |
– |
– |
– |
1 |
8 |
8 |
– |
|
20+20+10 |
20+10 |
20 |
– |
– |
– |
– |
1 |
9 |
9 |
– |
|
20+10+10 |
2×10 |
20 |
– |
– |
– |
– |
2 |
9A |
9A |
– |
|
10+15+20 |
10 |
15+20 |
2 |
9B |
9B |
||||||
10+15+20 |
10+15 |
20 |
2A |
9C |
9C |
||||||
CA with 4CCs |
4×20 |
20 |
3×20 |
– |
– |
– |
– |
– |
4 |
10 |
10 |
4×20 |
2×20 |
2×20 |
– |
– |
– |
– |
– |
4 or 7 |
11 |
11 |
|
3×20+15 |
20+15 |
2×20 |
– |
– |
– |
– |
– |
4 |
12 |
12 |
|
2×15+2×20 |
2×15 |
2×20 |
– |
– |
– |
– |
– |
5 |
13 |
13 |
|
3×20+15 |
2×20+15 |
20 |
– |
– |
– |
– |
– |
7 |
14 |
14 |
|
2×15+2×20 |
2×15+20 |
20 |
– |
– |
– |
– |
– |
8 |
15 |
15 |
|
3×20+10 |
2×20+10 |
20 |
– |
– |
– |
– |
– |
7 |
15A |
15A |
|
4×20 |
2×15+20 |
20 |
– |
– |
– |
– |
– |
8 |
15B |
15B |
|
10+3×20 |
10 |
3×20 |
6 |
15C |
15C |
||||||
2×10+2×20 |
2×10 |
2×20 |
6 |
15D |
15D |
||||||
2×10+20+15 |
2×10 |
20+15 |
9A |
15E |
15E |
||||||
10+3×20 |
10+20 |
2×20 |
4 |
15F |
15F |
||||||
10+15+2×20 |
10+15 |
2×20 |
5 |
15G |
15G |
||||||
10+15+2×20 |
10+15+20 |
20 |
8 |
15H |
15H |
||||||
CA with 5 CCs |
4×20+15 |
2×20+15 |
2×20 |
– |
– |
– |
– |
– |
– |
11 |
16 |
2×15+3×20 |
2×15+20 |
2×20 |
– |
– |
– |
– |
– |
– |
12 |
17 |
|
4×20+20 |
4×20 |
20 |
18 |
||||||||
3×20+2×20 |
3×20 |
2×20 |
19 |
||||||||
2×20+3×20 |
2×20 |
3×20 |
20 |
||||||||
20+4×20 |
20 |
4×20 |
21 |
||||||||
10+4×20 |
10 |
4×20 |
22 |
||||||||
10+20+3×20 |
10+20 |
3×20 |
23 |
||||||||
2×10+3×20 |
2×10 |
3×20 |
24 |
||||||||
10+2×20+2×20 |
10+2×20 |
2×20 |
25 |
||||||||
10+15+20+2×20 |
10+15+20 |
2×20 |
26 |
||||||||
CA with 6 CCs |
20+5×20 |
20 |
5×20 |
27 |
27 |
||||||
2×20+4×20 |
2×20 |
4×20 |
28 |
28 |
|||||||
CA with 7 CCs |
20+6×20 |
20 |
6×20 |
29 |
29 |
||||||
2×20+5×20 |
2×20 |
5×20 |
30 |
30 |
|||||||
Note 1: Void. Note 2: Void. Note 3: If DL category is signalled by the UE under test, then select the test point according to UE DL Category. Otherwise, select the test point according to the UE category signalled. |
Table 8.7.5.2-3: Minimum requirement (TDD FDD CA 256QAM)
Test number |
Bandwidth (MHz) |
Measurement channel |
Reference value |
||||
Total |
FDD CC |
TDD CC |
FDD CC |
TDD CC |
TB success rate [%] |
||
1 |
2×20 |
20 |
20 |
R.68 FDD |
R.68 TDD |
85 |
|
2 |
10+20 |
10 |
20 |
R.68-2 FDD |
R.68 TDD |
85 |
|
3 |
15+20 |
15 |
20 |
R.68-1 FDD |
R.68 TDD |
85 |
|
4 |
3×20 |
20 |
2×20 |
R.68 FDD |
R.68 TDD |
85 |
|
5 |
15+20+20 |
15 |
2×20 |
R.68-1 FDD |
R.68 TDD |
85 |
|
6 |
10+20+20 |
10 |
2×20 |
R.68-2 FDD |
R.68TDD |
85 |
|
7 |
3×20 |
2×20 |
20 |
R.68 FDD |
R.68 TDD |
85 |
|
8 |
20+20+15 |
20+15 |
20 |
R.68 FDD for 20MHz CC, R.68-1 FDD for 15MHz CC |
R.68 TDD |
85 |
|
9 |
20+20+10 |
20+10 |
20 |
R.68 FDD for 20MHz CC, R.68-2 FDD for 10MHz CC |
R.68 TDD |
85 |
|
9A |
20+10+10 |
2×10 |
20 |
R.68-2 FDD |
R.68 TDD |
85 |
|
9B |
10+15+20 |
10 |
15+20 |
R.68-2 FDD |
R.68-1 TDD for 15MHz CC R.68 TDD for 20MHz CC |
85 |
|
9C |
10+15+20 |
10+15 |
20 |
R.68-2 FDD for 10MHz CC, R.68-1 FDD for 15MHz CC |
R.68 TDD |
85 |
|
10 |
4×20 |
20 |
3×20 |
R.68-2 FDD |
R.68TDD |
85 |
|
11 |
4×20 |
2×20 |
2×20 |
R.68 FDD |
R.68 TDD |
85 |
|
12 |
3×20+15 |
20+15 |
2×20 |
R.68 FDD for 20MHz CC, R.68-1 FDD for 15MHz CC |
R.68 TDD |
85 |
|
13 |
2×15+2×20 |
2×15 |
2×20 |
R.68-1 FDD |
R.68 TDD |
85 |
|
14 |
3×20+15 |
2×20+15 |
20 |
R.68 FDD for 20MHz CC, R.68-1 FDD for 15MHz CC |
R.68 TDD |
85 |
|
15 |
2×15+2×20 |
2×15+20 |
20 |
R.68 FDD for 20MHz CC, R.68-1 FDD for 15MHz CC |
R.68 TDD |
85 |
|
15A |
3×20+10 |
2×20+10 |
20 |
R.68 FDD for 20MHz CC, R.68-2 FDD for 10MHz CC |
R.68 TDD |
85 |
|
15B |
4×20 |
3×20 |
20 |
R.68 FDD |
R.68TDD |
85 |
|
15C |
10+3×20 |
10 |
3×20 |
R.68-2 FDD |
R.68TDD |
85 |
|
15D |
2×10+2×20 |
2×10 |
2×20 |
R.68-2 FDD |
R.68TDD |
85 |
|
15E |
2×10+20+15 |
2×10 |
20+15 |
R.68-2 FDD |
R.68-1 TDD for 15MHz CC R.68 TDD for 20MHz CC |
85 |
|
15F |
10+3×20 |
10+20 |
2×20 |
R.68 FDD for 20MHz CC, R.68-2 FDD for 10MHz CC |
R.68 TDD |
85 |
|
15G |
10+15+2×20 |
10+15 |
2×20 |
R.68-2 FDD for 10MHz CC, R.68-1 FDD for 15MHz CC |
R.68 TDD |
85 |
|
15H |
10+15+2×20 |
10+15+20 |
20 |
R.68-2 FDD for 10MHz CC, R.68-1 FDD for 15MHz CC, R.68 FDD for 20MHz CC |
R.68 TDD |
85 |
|
16 |
4×20+15 |
2×20+15 |
2×20 |
R.68 FDD for 20MHz CC, R.68-1 FDD for 15MHz CC |
R.68 TDD |
85 |
|
17 |
2×15+3×20 |
2×15+20 |
2×20 |
R.68 FDD for 20MHz CC, R.68-1 FDD for 15MHz CC |
R.68 TDD |
85 |
|
18 |
4×20+20 |
4×20 |
20 |
R.68 FDD |
R.68 TDD |
85 |
|
19 |
3×20+2×20 |
3×20 |
2×20 |
R.68 FDD |
R.68 TDD |
85 |
|
20 |
2×20+3×20 |
2×20 |
3×20 |
R.68 FDD |
R.68 TDD |
85 |
|
21 |
20+4×20 |
20 |
4×20 |
R.68 FDD |
R.68 TDD |
85 |
|
22 |
10+4×20 |
10 |
4×20 |
R.68-2 FDD |
R.68 TDD |
85 |
|
23 |
10+20+3×20 |
10+20 |
3×20 |
R.68-2 FDD for 10MHz CC, R.68 FDD for 20MHz CC |
R.68 TDD |
85 |
|
24 |
2×10+3×20 |
2×10 |
3×20 |
R.68-2 FDD |
R.68 TDD |
85 |
|
25 |
10+2×20+2×20 |
10+2×20 |
2×20 |
R.68-2 FDD for 10MHz CC, R.68 FDD for 20MHz CC |
R.68 TDD |
85 |
|
26 |
10+15+20+2×20 |
10+15+20 |
2×20 |
R.68-2 FDD for 10MHz CC, R.68-1 FDD for 15MHz CC, R.68 FDD for 20MHz CC |
R.68 TDD |
85 |
|
27 |
20+5×20 |
20 |
5×20 |
R.68-2 FDD |
R.68 TDD |
85 |
|
28 |
2×20+4×20 |
2×20 |
4×20 |
R.68-2 FDD |
R.68 TDD |
85 |
|
29 |
20+6×20 |
20 |
6×20 |
R.68-2 FDD |
R.68 TDD |
85 |
|
30 |
2×20+5×20 |
2×20 |
5×20 |
R.68-2 FDD |
R.68 TDD |
85 |
Table 8.7.5.2-4: Test points for sustained data rate (FRC 256QAM)
CA config |
Maximum supported Bandwidth/ Bandwidth combination (MHz) |
Cat. 11, 12 |
DL Cat. 13 |
DL Cat. 15 |
DL Cat. 16 |
||||
Total |
FDD CC |
TDD CC |
DL Cat. 11, 12 |
||||||
CA with 2CCs |
2×20 |
20 |
20 |
1 |
1 |
– |
– |
||
10+20 |
10 |
20 |
2 |
2 |
|||||
15+20 |
15 |
20 |
3 |
3 |
– |
– |
|||
CA with 3CCs |
3×20 |
20 |
2×20 |
4 |
1 |
4 |
– |
||
15+20+20 |
15 |
2×20 |
5 |
3 |
5 |
– |
|||
10+20+20 |
10 |
2×20 |
6 |
2 |
6 |
– |
|||
3×20 |
2×20 |
20 |
7 |
1 |
7 |
– |
|||
20+20+15 |
20+15 |
20 |
8 |
1 |
8 |
– |
|||
20+20+10 |
20+10 |
20 |
9 |
1 |
9 |
– |
|||
20+10+10 |
2×10 |
20 |
9A |
2 |
9A |
||||
10+15+20 |
10 |
15+20 |
9B |
2 |
9B |
||||
10+15+20 |
10+15 |
20 |
9C |
3 |
9C |
||||
CA with 4CCs |
4×20 |
20 |
3×20 |
4 |
– |
10 |
10 |
||
4×20 |
2×20 |
2×20 |
4 or 7 |
– |
11 |
11 |
|||
3×20+15 |
20+15 |
2×20 |
8 |
– |
12 |
12 |
|||
2×15+2×20 |
2×15 |
2×20 |
5 |
– |
13 |
13 |
|||
3×20+15 |
2×20+15 |
20 |
7 |
– |
14 |
14 |
|||
2×15+2×20 |
2×15+20 |
20 |
8 |
– |
15 |
15 |
|||
3×20+10 |
2×20+10 |
20 |
7 |
– |
15A |
15A |
|||
4×20 |
2×15+20 |
20 |
8 |
– |
15B |
15B |
|||
10+3×20 |
10 |
3×20 |
6 |
15C |
15C |
||||
2×10+2×20 |
2×10 |
2×20 |
6 |
15D |
15D |
||||
2×10+20+15 |
2×10 |
20+15 |
9A |
15E |
15E |
||||
10+3×20 |
10+20 |
2×20 |
4 |
15F |
15F |
||||
10+15+2×20 |
10+15 |
2×20 |
5 |
15G |
15G |
||||
10+15+2×20 |
10+15+20 |
20 |
8 |
15H |
15H |
||||
CA with 5CCs |
4×20+15 |
2×20+15 |
2×20 |
– |
– |
14 or 12 |
16 |
||
2×15+3×20 |
2×15+20 |
2×20 |
– |
– |
15 or 12 |
17 |
|||
4×20+20 |
4×20 |
20 |
18 |
||||||
3×20+2×20 |
3×20 |
2×20 |
19 |
||||||
2×20+3×20 |
2×20 |
3×20 |
20 |
||||||
20+4×20 |
20 |
4×20 |
21 |
||||||
10+4×20 |
10 |
4×20 |
22 |
||||||
10+20+3×20 |
10+20 |
3×20 |
23 |
||||||
2×10+3×20 |
2×10 |
3×20 |
24 |
||||||
10+2×20+2×20 |
10+2×20 |
2×20 |
25 |
||||||
10+15+20+2×20 |
10+15+20 |
2×20 |
26 |
||||||
CA with 6CCs |
20+5×20 |
20 |
5×20 |
27 |
|||||
2×20+4×20 |
2×20 |
4×20 |
28 |
||||||
CA with 7CCs |
20+6×20 |
20 |
6×20 |
29 |
|||||
2×20+5×20 |
2×20 |
5×20 |
30 |
||||||
Note 1: If DL category is signalled by the UE under test, then select the test point according to UE DL Category. Otherwise, select the test point according to the UE category signalled. |