7.6 Blocking characteristics
36.1013GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Release 18TSUser Equipment (UE) radio transmission and reception
The blocking characteristic is a measure of the receiver’s ability to receive a wanted signal at its assigned channel frequency in the presence of an unwanted interferer on frequencies other than those of the spurious response or the adjacent channels, without this unwanted input signal causing a degradation of the performance of the receiver beyond a specified limit. The blocking performance shall apply at all frequencies except those at which a spurious response occur.
7.6.1 In-band blocking
In-band blocking is defined for an unwanted interfering signal falling into the UE receive band or into the first 15 MHz below or above the UE receive band at which the relative throughput shall meet or exceed the minimum requirement for the specified measurement channels.
For CA configurations including Band 46, in-band blocking in Band 46 is defined for a 20 MHz unwanted interfering signal falling into the UE receive band or into the first 60 MHz below or above the UE receive band (Table 7.6.1.1A-0a and Table 7.6.1.1A-0b).
For CA configurations including Band 49, in-band blocking in Band 49 is defined for an unwanted interfering signal falling into the UE receive band or into the first 60 MHz below or above the UE receive band (Table 7.6.1.1A-0a and Table 7.6.1.1A-0b).
7.6.1.1 Minimum requirements
The throughput shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annexes A.2.2, A.2.3 and A.3.2 (with one sided dynamic OCNG Pattern OP.1 FDD/TDD for the DL-signal as described in Annex A.5.1.1/A.5.2.1) with parameters specified in Tables 7.6.1.1-1 and 7.6.1.1-2. For operating bands with an unpaired DL part (as noted in Table 5.5-1), the requirements only apply for carriers assigned in the paired part.
Table 7.6.1.1-1: In band blocking parameters
Rx parameter |
Units |
Channel bandwidth |
|||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
||
Power in Transmission Bandwidth Configuration |
dBm |
REFSENS + channel bandwidth specific value below |
|||||
6 |
6 |
6 |
6 |
7 |
9 |
||
BWInterferer |
MHz |
1.4 |
3 |
5 |
5 |
5 |
5 |
FIoffset, case 1 |
MHz |
2.1+0.0125 |
4.5+0.0075 |
7.5+0.0125 |
7.5+0.0025 |
7.5+0.0075 |
7.5+0.0125 |
FIoffset, case 2 |
MHz |
3.5+0.0075 |
7.5+0.0075 |
12.5+0.0075 |
12.5+0.0125 |
12.5+0.0025 |
12.5+0.0075 |
NOTE 1: The transmitter shall be set to 4dB below PCMAX_L at the minimum uplink configuration specified in Table 7.3.1-2 with PCMAX_L as defined in subclause 6.2.5. NOTE 2: The interferer consists of the Reference measurement channel specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1 and set-up according to Annex C.3.1. NOTE 3: The REFSENS power level is specified in Table 7.3.1-1 and Table 7.3.1-1a for two and four antenna ports, respectively. NOTE 4: For DL category M1 and M2 UE, the reference sensitivity for category M1 in table 7.3.1E-3 and category M2 in Table 7.3.1E-8 should be used as REFSENS for the power in Transmission Bandwidth Configuration. NOTE5: For DL category M1 and M2 UE, the parameters for the applicable channel bandwidth apply. |
Table 7.6.1.1-2: In-band blocking
E-UTRA band |
Parameter |
Unit |
Case 1 |
Case 2 |
Case 3 |
Case 4 |
Case 5 |
Case 6 |
PInterferer |
dBm |
-56 |
-44 |
Void |
Void |
-38 |
-15 |
|
FInterferer (offset) |
MHz |
=-BW/2 – FIoffset,case 1 & =+BW/2 + FIoffset,case 1 |
≤-BW/2 – FIoffset,case 2 & ≥+BW/2 + FIoffset,case 2 |
-BW/2 – 11 |
||||
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 17, 18, 19, 20, 21, 22, 23, 25, 26, 27, 28, 31, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 48, 50, 51, 52, 53, 54, 65, 66, 68, 70, 72, 73, 74, 85, 87, 88 |
FInterferer |
MHz |
(NOTE 2) |
FDL_low – 15 to FDL_high + 15 |
||||
30 |
FInterferer |
MHz |
(NOTE 2) |
FDL_low – 15 to FDL_high + 15 |
FDL_low – 11 |
|||
71 |
FInterferer |
MHz |
(NOTE 2) |
FDL_low – 12 to FDL_high + 15 |
FDL-low – 12 |
|||
NOTE 1: For certain bands, the unwanted modulated interfering signal may not fall inside the UE receive band, but within the first 15 MHz below or above the UE receive band NOTE 2: For each carrier frequency the requirement is valid for two frequencies: a. the carrier frequency -BW/2 – FIoffset, case 1 and b. the carrier frequency +BW/2 + FIoffset, case 1 NOTE 3: FInterferer range values for unwanted modulated interfering signal are interferer center frequencies |
For the UE which supports inter band CA configuration in Table 7.3.1-1A, PInterferer power defined in Table 7.6.1.1-2 is increased by the amount given by ΔRIB,c in Table 7.3.1-1A.
7.6.1.1A Minimum requirements for CA
For inter-band carrier aggregation with one component carrier per operating band and the uplink assigned to one E-UTRA band the in-band blocking requirements are defined with the uplink active on the band(s) other than the band whose downlink is being tested. For adjacent downlink bands separated by less than 30 MHz the frequency separation between the center frequencies of adjacent component carriers belonging to different bands shall be ≥ BW1/2 + BW2/2 + 2FIoffset,case j for Case j interferers, j = 1,2, where BWk/2 are the channel bandwidths of carrier k, k = 1,2. The UE shall meet the requirements specified in subclause 7.6.1.1 for each component carrier while all downlink carriers are active. For the UE which supports inter band CA configuration in Table 7.3.1-1A, PInterferer power defined in Table 7.6.1.1-2 is increased by the amount given by ΔRIB,c in Table 7.3.1-1A. For E-UTRA CA configurations including an operating band without uplink operation or an operating band with an unpaired DL part (as noted in Table 5.5-1), the requirements for all downlinks shall be met with the single uplink carrier active in each band capable of UL operation. The requirements for the component carrier configured in the operating band without uplink operation are specified in Table 7.6.1.1A-0, Table 7.6.1.1A-0a and Table 7.6.1.1A-0b. The requirements for a component carrier configured in Band 49 are specified in Table 7.6.1.1A-0a and Table 7.6.1.1A-0b.
Table 7.6.1.1A-0: In-band blocking for additional operating bands for carrier aggregation
E-UTRA band |
Parameter |
Unit |
Case 1 |
Case 2 |
PInterferer |
dBm |
-56 |
-44 |
|
FInterferer (offset) |
MHz |
=-BW/2 – FIoffset,case 1 & =+BW/2 + FIoffset,case 1 |
≤-BW/2 – FIoffset,case 2 & ≥+BW/2 + FIoffset,case 2 |
|
29, 32, 67, 69, 75, 76 |
FInterferer |
MHz |
(NOTE 2) |
FDL_low – 15 to FDL_high + 15 |
NOTE 1: For certain bands, the unwanted modulated interfering signal may not fall inside the UE receive band, but within the first 15 MHz below or above the UE receive band NOTE 2: For each carrier frequency the requirement is valid for two frequencies: a. the carrier frequency -BW/2 – FIoffset, case 1 and b. the carrier frequency +BW/2 + FIoffset, case 1 NOTE 3: FInterferer range values for unwanted modulated interfering signal are interferer center frequencies |
Table 7.6.1.1A-0a: In band blocking parameters for additional operating bands for carrier aggregation
E-UTRA band |
Rx parameter |
Units |
Channel bandwidth |
|||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
|||
46 (NOTE 3) |
Power in Transmission Bandwidth Configuration |
dBm |
REFSENS + channel bandwidth specific value below |
|||||
6 |
9 |
|||||||
BWInterferer |
MHz |
20 |
20 |
|||||
FIoffset, case 1 |
MHz |
30+0.0025 |
30+0.0125 |
|||||
FIoffset, case 2 |
MHz |
50+0.0125 |
50+0.0075 |
|||||
49 (NOTE 3) |
Power in Transmission Bandwidth Configuration |
dBm |
6 |
6 |
||||
BWInterferer |
MHz |
10 |
20 |
|||||
FIoffset, case 1 |
MHz |
15+0.025 |
30+0.125 |
|||||
FIoffset, case 2 |
MHz |
25+0.075 |
50+0.075 |
|||||
NOTE 1: The transmitter shall be set to 4dB below PCMAX_L at the minimum uplink configuration specified in Table 7.3.1-2 with PCMAX_L as defined in subclause 6.2.5. NOTE 2: The interferer consists of the Reference measurement channel specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD/FS3 as described in Annex A.5.1.1/A.5.2.1/A.5.4.1 and set-up according to Annex C.3.1 NOTE 3: The interferer consists of the Reference measurement channel specified in Annex A.3.2 (TBD) |
Table 7.6.1.1A-0b: In-band blocking for additional operating bands for carrier aggregation
E-UTRA band |
Parameter |
Unit |
Case 1 |
Case 2 |
PInterferer |
dBm |
-50 |
-44 |
|
FInterferer (offset) |
MHz |
=-BW/2 – FIoffset,case 1 & =+BW/2 + FIoffset,case 1 |
≤-BW/2 – FIoffset,case 2 & ≥+BW/2 + FIoffset,case 2 |
|
46, 49 |
FInterferer |
MHz |
(Note 2) |
FDL_low – 60 to FDL_high + 60 |
NOTE 1: For certain bands, the unwanted modulated interfering signal may not fall inside the UE receive band, but within the first 15 MHz or 60 MHz below or above the UE receive band NOTE 2: For each carrier frequency the requirement is valid for two frequencies: a. the carrier frequency -BW/2 – FIoffset, case 1 and b. the carrier frequency +BW/2 + FIoffset, case 1 NOTE 3: FInterferer range values for unwanted modulated interfering signal are interferer center frequencies |
For E-UTRA CA configurations listed in Table 7.3.1A-0a under conditions for which reference sensitivity for the operating band being tested is N/A, the in-band blocking requirements of subclause 7.6.1.1A do not apply.
For intra-band contiguous carrier aggregation the downlink SCC(s) shall be configured at nominal channel spacing to the PCC. For FDD, the PCC shall be configured closest to the uplink band. All downlink carriers shall be active throughout the test. The uplink output power shall be set as specified in Table 7.6.1.1A-1 with the uplink configuration set according to Table 7.3.1A-1 for the applicable carrier aggregation configuration. For UE(s) supporting one uplink carrier, the uplink configuration of the PCC shall be in accordance with Table 7.3.1-2. The UE shall fulfil the minimum requirement in presence of an interfering signal specified in Tables 7.6.1.1A-1 and Tables 7.6.1.1A-2 being on either side of the aggregated signal. The throughput of each carrier shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annexes A.2.2, A.2.3 and A.3.2 (with one sided dynamic OCNG Pattern OP.1 FDD/TDD for the DL-signal as described in Annex A.5.1.1/A.5.2.1) with parameters specified in Tables 7.6.1.1A-1 and 7.6.1.1A-2. For operating bands with an unpaired DL part (as noted in Table 5.5-1), the requirements also apply for an SCC assigned in the unpaired part with parameters specified in Tables 7.6.2.1A-1 and 7.6.2.1A-2.
For intra-band non-contiguous carrier aggregation with one uplink carrier and two or more downlink sub-blocks, each larger than or equal to 5 MHz, the in-band blocking requirements are defined with the uplink configuration in accordance with Table 7.3.1A-3. For this uplink configuration, the UE shall meet the requirements for each sub-block as specified in subclause 7.6.1.1 and in this subclause for one component carrier and two component carriers per sub-block, respectively. The requirements apply for in-gap and out-of-gap interferers while all downlink carriers are active.
Table 7.6.1.1A-1: In band blocking parameters
Rx Parameter |
Units |
CA Bandwidth Class |
||||
B |
C |
D |
E |
F |
||
Pw in Transmission Bandwidth Configuration, per CC |
dBm |
REFSENS + CA Bandwidth Class specific value below |
||||
9 |
12 |
13.8 |
15 |
16 |
||
BWInterferer |
MHz |
5 |
5 |
5 |
5 |
5 |
FIoffset, case 1 |
MHz |
7.5 |
7.5 |
7.5 |
7.5 |
7.5 |
FIoffset, case 2 |
MHz |
12.5 |
12.5 |
12.5 |
12.5 |
12.5 |
NOTE 1: The transmitter shall be set to 4dB below PCMAX_L,c or PCMAX_L as defined in subclause 6.2.5A NOTE 2: The interferer consists of the Reference measurement channel specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1 and set-up according to Annex C.3.1 |
Table 7.6.1.1A-2: In-band blocking
CA configuration |
Parameter |
Unit |
Case 1 |
Case 2 |
PInterferer |
dBm |
-56 |
-44 |
|
FInterferer (offset) |
MHz |
=-Foffset– FIoffset,case 1 & =+Foffset + FIoffset,case 1 |
≤-Foffset– FIoffset,case 2 & ≥+Foffset + FIoffset,case 2 |
|
CA_1C, CA_2C, CA_3B, CA_3C, CA_5B, CA_7B, CA_7C, CA_8B, CA_12B, CA_23B, CA_27B, CA_28C, CA_38C, CA_39C, CA_40C, CA_40D, CA_40E, CA_40F, CA_41C, CA_41D, CA_41E, CA_41F, CA_42C, CA_42D, CA_42E, CA_42F, CA_43C, CA_48B, CA_48C, CA_48D, CA_48E, CA_48F, CA_66B, CA_66C, CA_66D, CA_70C |
FInterferer (Range) |
MHz |
(NOTE 2) |
FDL_low – 15 to FDL_high + 15 |
NOTE 1: For certain bands, the unwanted modulated interfering signal may not fall inside the UE receive band, but within the first 15 MHz below or above the UE receive band NOTE 2: For each carrier frequency the requirement is valid for two frequencies: a. the carrier frequency -Foffset – FIoffset, case 1 and b. the carrier frequency +Foffset + FIoffset, case 1 NOTE 3: Foffset is the frequency offset from the center frequency of the CC being tested to the edge of aggregated channel bandwidth. NOTE 4: The Finterferer (offset) is the frequency separation of the center frequency of the carrier closest to the interferer and the center frequency of the interferer and shall be further adjusted to MHz to be offset from the sub-carrier raster. |
For combinations of intra-band and inter-band carrier aggregation and one uplink carrier assigned to one E-UTRA band, the requirement is defined with the uplink active in the band other than that supporting the downlink(s) under test. The uplink configuration shall be in accordance with Table 7.3.1A-3 when the uplink is active in the band supporting two or more non-contiguous component carriers, Table 7.3.1A-1 when the uplink is active in a band supporting two contiguous component carriers and in accordance with Table 7.3.1-2 when the uplink is active in a band supporting one carrier per band. The downlink PCC shall be configured closer to the uplink operating band than the downlink SCC(s) when the uplink is active in band(s) supporting contiguous aggregation. For these uplink configurations, the UE shall meet the in-band blocking requirements for intra-band non-contiguous carrier aggregation with RIBNC = 0 dB for all sub-block gaps (Table 7.3.1A-3) for the two or more non-contiguous downlink sub-blocks, the requirements for intra-band contiguous carrier aggregation for the contiguously aggregated downlink carriers and for any remaining component carrier(s) the requirements specified in subclause 7.6.1. For contiguously aggregated component carriers configured in Band 46, the said requirements for intra-band contiguous carrier aggregation of downlink carriers are replaced by requirements in Table 7.6.1.1A-3 and 7.6.1.1A-4. For non-contiguously aggregated component carriers configured in Band 46, the said requirements are applied to each sub-block for in-gap and out-of-gap interferers. For the sub-block with a single component carrier, the requirement is replaced by Table 7.6.1.1A-0a and 7.6.1.1A-0b. For the sub-block with two or more contiguous component carriers, the requirement is replaced by Table 7.6.1.1A-3 and 7.6.1.1A-4. All downlink carriers shall be active throughout the tests and the requirements for the downlinks shall be met with the single uplink carrier active in each band capable of uplink operation.
Table 7.6.1.1A-3: In band blocking parameters
E-UTRA Band |
Rx Parameter |
Units |
CA Bandwidth Class |
||||
B |
C |
D |
E |
F |
|||
46 |
Pw in Transmission Bandwidth Configuration, per CC |
dBm |
REFSENS + CA Bandwidth Class specific value below |
||||
12 |
13.8 |
15 |
|||||
BWInterferer |
MHz |
20 |
20 |
20 |
|||
FIoffset, case 1 |
MHz |
30 |
30 |
30 |
|||
FIoffset, case 2 |
MHz |
50 |
50 |
50 |
|||
NOTE 1: In a band capable of uplink operation, the transmitter shall be set to 4dB below PCMAX_L,c or PCMAX_L as defined in subclause 6.2.5A NOTE 2: The interferer consists of the Reference measurement channel specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD/FS3 as described in Annex A.5.1.1/A.5.2.1/A.5.4.1 and set-up according to Annex C.3.1 |
Table 7.6.1.1A-4: In-band blocking
E-UTRA Band |
Parameter |
Unit |
Case 1 |
Case 2 |
PInterferer |
dBm |
-50 |
-44 |
|
FInterferer (offset) |
MHz |
=-Foffset– FIoffset,case 1 & =+Foffset + FIoffset,case 1 |
≤-Foffset– FIoffset,case 2 & ≥+Foffset + FIoffset,case 2 |
|
46 |
FInterferer (Range) |
MHz |
(Note 2) |
FDL_low – 60 to FDL_high + 60 |
NOTE 1: For certain bands, the unwanted modulated interfering signal may not fall inside the UE receive band, but within the first 15 MHz below or above the UE receive band NOTE 2: For each carrier frequency the requirement is valid for two frequencies: a. the carrier frequency -Foffset – FIoffset, case 1 and b. the carrier frequency +Foffset + FIoffset, case 1 NOTE 3: Foffset is the frequency offset from the center frequency of the CC being tested to the edge of aggregated channel bandwidth. NOTE 4: The Finterferer (offset) is the frequency separation of the center frequency of the carrier closest to the interferer and the center frequency of the interferer and shall be further adjusted to MHz to be offset from the sub-carrier raster. |
7.6.1.1D Minimum requirements for ProSe
The throughput shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annex A.6.2.
Table 7.6.1.1D-1: In band blocking parameters for ProSe Direct Discovery
Rx parameter |
Units |
Channel bandwidth |
|||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
||
Power in Transmission Bandwidth Configuration |
dBm |
PREFSENS_ProSe + channel bandwidth specific value below + Poffset |
|||||
6 |
6 |
7 |
9 |
||||
BWInterferer |
MHz |
5 |
5 |
5 |
5 |
||
FIoffset, case 1 |
MHz |
7.5+0.0125 |
7.5+0.0025 |
7.5+0.0075 |
7.5+0.0125 |
||
FIoffset, case 2 |
MHz |
12.5+0.0075 |
12.5+0.0125 |
12.5+0.0025 |
12.5+0.0075 |
||
Poffset |
dB |
10.9 |
13.9 |
15.7 |
16.9 |
||
NOTE 1: The interferer is QPSK modulated PUSCH containing data and reference symbols. Normal cyclic prefix is used. The data content shall be uncorrelated to the wanted signal and modulated according to clause 5 of TS36.211 |
Table 7.6.1.1D-2: In band blocking parameters for ProSe Direct Communication
Rx parameter |
Units |
Channel bandwidth |
|||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
||
Power in Transmission Bandwidth Configuration |
dBm |
PREFSENS_ProSe + channel bandwidth specific value below |
|||||
6 |
6 |
7 |
9 |
||||
BWInterferer |
MHz |
5 |
5 |
5 |
5 |
||
FIoffset, case 1 |
MHz |
7.5+0.0125 |
7.5+0.0025 |
7.5+0.0075 |
7.5+0.0125 |
||
FIoffset, case 2 |
MHz |
12.5+0.0075 |
12.5+0.0125 |
12.5+0.0025 |
12.5+0.0075 |
||
NOTE 1: The interferer is QPSK modulated PUSCH containing data and reference symbols. Normal cyclic prefix is used. The data content shall be uncorrelated to the wanted signal and modulated according to clause 5 of TS36.211 |
Table 7.6.1.1D-3: In-band blocking for ProSe
E-UTRA ProSe band |
Parameter |
Unit |
Case 1 |
Case 2 |
|
PInterferer |
dBm |
-56 |
-44 |
||
FInterferer (offset) |
MHz |
=-BW/2 – FIoffset,case 1 & =+BW/2 + FIoffset,case 1 |
≤-BW/2 – FIoffset,case 2 & ≥+BW/2 + FIoffset,case 2 |
||
2,3,4,7,14, 20,26,28,31 |
FInterferer |
MHz |
(NOTE 2) |
FDL_low – 15 to FDL_high + 15 |
|
NOTE 1: For certain bands, the unwanted modulated interfering signal may not fall inside the UE receive band, but within the first 15 MHz below or above the UE receive band NOTE 2: For each carrier frequency the requirement is valid for two frequencies: a. the carrier frequency -BW/2 – FIoffset, case 1 and b. the carrier frequency +BW/2 + FIoffset, case 1 NOTE 3: FInterferer range values for unwanted modulated interfering signal are interferer center frequencies |
For the UE which supports inter band CA configuration in Table 7.3.1-1A, PInterferer power defined in Table 7.6.1.1D-3 is increased by the amount given by ΔRIB,c in Table 7.3.1-1A.
7.6.1.1F Minimum requirements for category NB1 and NB2
Category NB1 and NB2 UE throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A.3.2 with parameters specified in Table 7.6.1.1F-1.
Table 7.6.1.1F-1: In-band blocking parameters for category NB1 and NB2
IBB1 test Parameters |
|
Category NB1 or NB2 signal power (Pwanted ) / dBm |
REFSENS + 6 dB |
Interferer |
E-UTRA |
Interferer signal power (PInterferer ) / dBm |
– 56 dBm |
Interferer bandwidth |
5 MHz |
Interferer offset from category NB1 or NB2 channel edge |
+7.5 MHz + 0.005 MHz and -7.5 MHz – 0.005 MHz |
IBB2 test Parameters |
|
Category NB1 or NB2 signal power (Pwanted ) / dBm |
REFSENS + 6 dB |
Interferer |
E-UTRA |
Interferer signal power (PInterferer ) / dBm |
– 44 dBm |
Interferer bandwidth |
5 MHz |
Interferer offset range from category NB1 or NB2 channel edge |
From +12.5 MHz to FDL_high + 15 MHz and From -12.5 MHz to FDL_low – 15 MHz |
7.6.1.1G Minimum requirements for V2X
The V2X UE throughput shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annex A.8.2 with paramteters defined in Table 7.6.1.1G-1 and Table 7.6.1.1G-2.
Table 7.6.1.1G-1: In band blocking parameters
Rx parameter |
Units |
Channel bandwidth |
|||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
||
Power in Transmission Bandwidth Configuration |
dBm |
PREFSENS_V2X + channel bandwidth specific value below |
|||||
6 |
9 |
||||||
BWInterferer |
MHz |
10 |
10 |
||||
FIoffset, case 1 |
MHz |
15+0.0025 |
15+0.005 |
||||
FIoffset, case 2 |
MHz |
25+0.0075 |
25+0.0025 |
||||
NOTE 1: The interferer is QPSK modulated PUSCH containing data and reference symbols. Normal cyclic prefix is used. The data content shall be uncorrelated to the wanted signal and modulated according to clause 5 of TS36.211 |
Table 7.6.1.1G-2: In-band blocking
E-UTRA V2X band |
Parameter |
Unit |
Case 1 |
Case 2 |
PInterferer |
dBm |
-44 |
-44 |
|
FInterferer (offset) |
MHz |
=-BW/2 – FIoffset,case 1 & =+BW/2 + FIoffset,case 1 |
≤-BW/2 – FIoffset,case 2 & ≥+BW/2 + FIoffset,case 2 |
|
47 |
FInterferer |
MHz |
(NOTE 2) |
FDL_low –30 to FDL_high + 30 |
NOTE 1: For certain bands, the unwanted modulated interfering signal may not fall inside the UE receive band, but within the first 15 MHz below or above the UE receive band NOTE 2: For each carrier frequency the requirement is valid for two frequencies: a. the carrier frequency -BW/2 – FIoffset, case 1 and b. the carrier frequency +BW/2 + FIoffset, case 1 NOTE 3: FInterferer range values for unwanted modulated interfering signal are interferer center frequencies |
When UE is configured for simultaneous E-UTRA V2X sidelink and E-UTRA downlink reception for inter-band E-UTRA V2X / E-UTRA bands specified in Table 5.5G-2, the requirements in subclause 7.6.1.1G apply for the E-UTRA V2X sidelink reception and the requirements in subclause 7.6.1.1 apply for the E-UTRA downlink reception while all downlink carriers are active.
For intra-band contiguous multi-carrier operation, the V2X UE throughput shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annex A.8.2 with paramteters defined in Table 7.6.1.1G-3 and Table 7.6.1.1G-4.
Table 7.6.1.1G-3: In band blocking parameters for intra-band contiguous multi-carrier for V2X UE
Rx Parameter |
Units |
V2X Bandwidth Class |
||||
B |
C/ C1 |
D |
E |
F |
||
Pw in Transmission Bandwidth Configuration, per CC |
dBm |
REFSENS + V2X Bandwidth Class specific value below |
||||
9 |
12 |
|||||
BWInterferer |
MHz |
10 |
10 |
|||
FIoffset, case 1 |
MHz |
15 |
15 |
|||
FIoffset, case 2 |
MHz |
25 |
25 |
Table 7.6.1.1G-4: In-band blocking for intra-band contiguous multi-carrier for V2X UE
V2X multi-carrier configuration |
Parameter |
Unit |
Case 1 |
Case 2 |
PInterferer |
dBm |
-44 |
-44 |
|
FInterferer (offset) |
MHz |
=-Foffset– FIoffset,case 1 & =+Foffset + FIoffset,case 1 |
≤-Foffset– FIoffset,case 2 & ≥+Foffset + FIoffset,case 2 |
|
V2X_47B, V2X_47C, V2X_47C1 |
FInterferer (Range) |
MHz |
(NOTE 2) |
FDL_low – 30 to FDL_high + 30 |
NOTE 1: For certain bands, the unwanted modulated interfering signal may not fall inside the UE receive band, but within the first 30 MHz below or above the UE receive band NOTE 2: For each carrier frequency the requirement is valid for two frequencies: a. the carrier frequency -Foffset – FIoffset, case 1 and b. the carrier frequency +Foffset + FIoffset, case 1 NOTE 3: Foffset is the frequency offset from the center frequency of the CC being tested to the edge of aggregated channel bandwidth. NOTE 4: The Finterferer (offset) is the frequency separation of the center frequency of the carrier closest to the interferer and the center frequency of the interferer and shall be further adjusted to MHz to be offset from the sub-carrier raster. NOTE 5: The requirement is applied for multi-carrier intra-band con-current receptions when 2 carrier transmissions are activated at the same time. |
7.6.2 Out-of-band blocking
Out-of-band band blocking is defined for an unwanted CW interfering signal falling more than 15 MHz below or above the UE receive band. For the first 15 MHz below or above the UE receive band the appropriate in-band blocking or adjacent channel selectivity in subclause 7.5.1 and subclause 7.6.1 shall be applied.
For CA configurations including Band 46 or Band 49, out-of-band band blocking is defined for an unwanted CW interfering signal falling more than 60 MHz below or above the UE receive band (see Table 7.6.2.1A-0a). For the first 60 MHz below or above the UE receive band the appropriate in-band blocking or adjacent channel selectivity in subclause 7.5.1A and subclause 7.6.1A shall be applied.
7.6.2.1 Minimum requirements
The throughput shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annexes A.2.2, A.2.3 and A.3.2 (with one sided dynamic OCNG Pattern OP.1 FDD/TDD for the DL-signal as described in Annex A.5.1.1/A.5.2.1) with parameters specified in Tables 7.6.2.1-1 and 7.6.2.1-2. For operating bands with an unpaired DL part (as noted in Table 5.5-1), the requirements only apply for carriers assigned in the paired part.
For Table 7.6.2.1-2 in frequency range 1, 2 and 3, up to exceptions are allowed for spurious response frequencies in each assigned frequency channel when measured using a 1MHz step size, where is the number of resource blocks in the downlink transmission bandwidth configuration (see Figure 5.6-1). For these exceptions the requirements of subclause 7.7 Spurious response are applicable.
For Table 7.6.2.1-2 in frequency range 4, up to exceptions are allowed for spurious response frequencies in each assigned frequency channel when measured using a 1MHz step size, where is the number of resource blocks in the downlink transmission bandwidth configurations (see Figure 5.6-1) and is the number of resource blocks allocated in the uplink. For these exceptions the requirements of clause 7.7 spurious response are applicable.
Table 7.6.2.1-1: Out-of-band blocking parameters
Rx Parameter |
Units |
Channel bandwidth |
|||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
||
Power in Transmission Bandwidth Configuration |
dBm |
REFSENS + channel bandwidth specific value below |
|||||
6 |
6 |
6 |
6 |
7 |
9 |
||
NOTE 1: The transmitter shall be set to 4dB below PCMAX_L at the minimum uplink configuration specified in Table 7.3.1-2 with PCMAX_L as defined in subclause 6.2.5. NOTE 2: Reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2. NOTE 3: The REFSENS power level is specified in Table 7.3.1-1 and Table 7.3.1-1a for two and four antenna ports, respectively. NOTE 4: For DL category M1 and M2 UE, the reference sensitivity for category M1 in table 7.3.1E-3 and category M2 in Table 7.3.1E-8 should be used as REFSENS for the power in Transmission Bandwidth Configuration. NOTE5: For DL category M1 and M2 UE, the parameters for the applicable channel bandwidth apply. |
Table 7.6.2.1-2: Out of band blocking
E-UTRA band |
Parameter |
Units |
Frequency |
|||
Range 1 |
Range 2 |
Range 3 |
Range 4 |
|||
PInterferer |
dBm |
-44 |
-30 |
-15 |
-15 |
|
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 30, 31, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42 (NOTE 2), 43 (NOTE 2), 44, 45, 48 (NOTE 2), 50, 51, 52 (NOTE 6), 539, 54, 65, 66, 68, 70, 71, 72, 73, 74, 85, 87, 88 |
FInterferer (CW) |
MHz |
FDL_low -15 to FDL_low -60 |
FDL_low -60 to FDL_low -85 |
FDL_low -85 to 1 MHz |
– |
FDL_high +15 to FDL_high + 60 |
FDL_high +60 to FDL_high +85 |
FDL_high +85 to +12750 MHz |
– |
|||
2, 5, 12, 17, 85 |
FInterferer |
MHz |
– |
– |
– |
FUL_low – FUL_high (NOTE 5) |
NOTE 1: For the UE which supports both Band 11 and Band 21 the out of blocking is FFS. NOTE 2: The power level of the interferer (PInterferer) for Range 3 shall be modified to -20 dBm for FInterferer > 2800 MHz and FInterferer < 4400 MHz. The power level of the interferer (PInterferer) for Range 3 shall be modified to -20 dBm for FInterferer > 2800 MHz and FInterferer < 4800 MHz when UE supports both E-UTRA band B42 and NR bands n77, n78. NOTE 3: For the UE that supports both Band 4 and Band 66, the out-of-blocking frequency range for Band 4 is defined relative to FDL_low and FDL_high of Band 66. NOTE 4: For a UE supporting CA_20A-28A, CA_1A-3A-7A-20A-28A, CA_1A-3A-20A-28A, CA_1A-3A-3A-20A-28A, CA_1A-7A-20A-28A, CA_1A-20A-28A, CA_3A-7A-20A-28A, CA_3A-20A-28A or CA_7A-20A-28A the requirements for Band 20 and Band 28 apply with FDL_low given by the lower limit of the restricted operating frequency range in Band 28 and FDL_high by Band 20 (Table 5.5A-2). NOTE 5: Range 4 requirement does not apply to category M1 and M2. NOTE 6: The power level of the interferer (PInterferer) for Range 3 shall be modified to -20 dBm for FInterferer > 2700 MHz and FInterferer < 4000 MHz. NOTE 7: For band 51 the FDL_high of band 50 is applied as FDL_high for band 51. NOTE 8: For UEs supporting both bands 38 and 41, the FDL_high and FDL_low of band 41 is applied as FDL_high and FDL_low for band 38. NOTE 9: The power level of the interferer (PInterferer) for Range 3 shall be modified to [-20 dBm] for FInterferer > [2580 MHz] and FInterferer < [2775 MHz]. |
7.6.2.1A Minimum requirements for CA
For inter-band carrier aggregation with one component carrier per operating band and the uplink assigned to one E-UTRA band, the out-of-band blocking requirements are defined with the uplink active on the band(s) other than the band whose downlink is being tested. The throughput in the downlink measured shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annexes A.2.2, A.2.3 and A.3.2 (with one sided dynamic OCNG Pattern OP.1 FDD/TDD for the DL-signal as described in Annex A.5.1.1/A.5.2.1) with parameters specified in Tables 7.6.2.1-1 and 7.6.2.1A-0. For E-UTRA CA configurations including an operating band without uplink operation (as noted in Table 5.5-1), the requirements for all downlinks shall be met with the uplink active in the band(s) capable of UL operation. For the E-UTRA CA configurations with band 46 or Band 49, the parameters specified in Table 7.6.2.1A-0 are replaced by those specified in Table 7.6.2.1A-0a. The UE shall meet these requirements for each component carrier while all downlink carriers are active.
For inter-band carrier aggregation with one component carrier per operating band and the uplink active in two E-UTRA bands, the out-of-band blocking requirements specified above shall be met with the transmitter power for the uplink set to 7 dB below PCMAX_L,c for each serving cell c.
For E-UTRA CA configurations including an operating band without uplink band or an operating band with an unpaired DL part (as noted in Table 5.5-1), the requirements for all downlinks shall be met with the single uplink carrier active in each band capable of UL operation. For E-UTRA CA configurations listed in Table 7.3.1A-0a under conditions for which reference sensitivity for the operating band being tested is N/A, the out-of-band blocking requirements of subclause 7.6.2.1A do not apply.
Table 7.6.2.1A-0: out-of-band blocking for inter-band carrier aggregation
Parameter |
Unit |
Range 1 |
Range 2 |
Range 3 |
Pw |
dBm |
Table 7.6.2.1-1 for all component carriers |
||
Pinterferer |
dBm |
-44 + RIB,c |
-30 + RIB,c |
-15 + RIB,c |
Finterferer (CW) |
MHz |
-60 < f – FDL_Low(j) < -15 or 15 < f – FDL_High(j) < 60 |
-85 < f – FDL_Low(j) ≤ -60 or 60 ≤ f – FDL_High(j) < 85 |
1 ≤ f ≤ FDL_Low(1) – 85 or FDL_High(j) + 85 ≤ f ≤ FDL_Low(j+1) – 85 with j < X or FDL_High(X) + 85 ≤ f ≤ 12750 |
NOTE 1: FDL_Low(j) and FDL_High(j) denote the respective lower and upper frequency limits of the operating band containing carrier j, j = 1,…,X, with carriers numbered in increasing order of carrier frequency and X the number of component carriers in the band combination. NOTE 2: For FDL_Low(j+1) – FDL_High(j) < 145 MHz and FInterferer in FDL_High(j) < f < FDL_Low(j+1) with j < X, FInterferer can be in both Range 1 and Range 2. Then the lower of the PInterferer applies. NOTE 3: For FDL_Low(j) – 15 MHz ≤ f ≤ FDL_High(j) + 15 MHz the appropriate adjacent channel selectivity and in-band blocking requirments in the respective subclauses 7.5.1A and 7.6.1.1A shall be applied for carrier j. NOTE 4: RIB,c according to Table 7.3.1-1A applies when serving cell c is measured. NOTE 5: For inter-band CA combinations containing Bands 42, 43, or 48, the interferer with respect to Band 42, Band 43, or Band 48 shall have power level (PInterferer) for Range 3 modified to -20 + RIB,c dBm for FInterferer > 2800 MHz and FInterferer < 4400 MHz. NOTE 6: For inter-band CA combinations containing Bands 7 and 38 simultaneously, for FInterferer Bands 7 and 38 are considered as one single band as follows: FDL_Low = 2570 MHz and FDL_High = 2690 MHz. For Range 2, the following applies for FDL_Low: -95 < f – FDL_Low ≤ -60 or 60 ≤ f – FDL_High < 85 . For Range 3 the following applies 1 ≤ f ≤ FDL_Low -95 or FDL_High + 85 ≤ f ≤ 12750. For UEs supporting both bands 38 and 41, FDL_Low = 2496 MHz. NOTE 7: For CA_20A-28A, CA_1A-3A-7A-20A-28A, CA_1A-3A-20A-28A, CA_1A-3A-3A-20A-28A, CA_1A-7A-20A-28A, CA_1A-20A-28A, CA_3A-7A-20A-28A, CA_3A-20A-28A and CA_7A-20A-28A the FDL_low(1) is given by the lower limit of the restricted operating frequency range in Band 28 and FDL_high(2) by Band 20 (Table 5.5A-2). NOTE 8: For inter-band CA combinations including DL in band 76, the FDL_high of band 75 is applied as FDL_high for band 76. NOTE 9: For CA band combinations including DL in band 32, FDL_high of band 75 is applied as FDL_high for band 32, and FDL_low of band 76 is applied as FDL_low for band 32. |
Table 7.6.2.1A-0a: out-of-band blocking for inter-band carrier aggregation with band 46 or Band 49 and with one active uplink
Parameter |
Unit |
Range 1 |
Range 2 |
Range 3 |
Pwanted |
dBm |
Table 7.6.2.1-1 for component carriers in bands with j ≤ K and Table 7.6.1.1A-0a for component carriers in bands with j > K |
||
Pinterferer |
dBm |
-44 + RIB,c |
-30 + RIB,c |
-15 + RIB,c (NOTE 5) |
Finterferer (CW) |
MHz |
-60 < f – FDL_Low(j) < -15 with j ≤ K or 15 < f – FDL_High(j) < 60 with j ≤ K |
-856 < f – FDL_Low(j) ≤ -60 or 60 ≤ f – FDL_High(j) < 856 |
1 ≤ f ≤ FDL_Low(j) – 856 or FDL_High(j) + 856 ≤ f ≤ 12750 |
NOTE 1: FDL_Low(j) and FDL_High(j), j = 1,…,K,…N, denote the respective lower and upper frequency limits of the (non-overlapping) operating bands of the CA configuration numbered in increasing order of frequency, with N the number of bands in the band combination and K the number of bands with FDL_High ≤ 3800 MHz for Band 46 and FDL_High ≤ 2700 MHz for Band 49. NOTE 2: For FDL_Low(j) – 15 MHz ≤ f ≤ FDL_High(j) + 15 MHz the appropriate adjacent channel selectivity and in-band blocking requirements in the respective subclauses 7.5.1A and 7.6.1.1A shall be applied for carrier j ≤ K . NOTE 3: For FDL_Low(j) – 60 MHz ≤ f ≤ FDL_High(j) + 60 MHz the appropriate adjacent channel selectivity and in-band blocking requirements in the respective subclauses 7.5.1A and 7.6.1.1A shall be applied for carrier K < j ≤ N. NOTE 4: RIB,c according to Table 7.3.1-1A applies when serving cell c is measured. NOTE 5: The power level (PInterferer) for Range 3 is modified to -20 dBm for FInterferer > 4400 MHz except for band combinations with Band 42 or Band 43 for which PInterferer for Range 3 is modified to -20 dBm for FInterferer > 2800 MHz. NOTE 6: The -85 MHz and 85 MHz offset from FDL_Low(j) and FDL_High(j) is modified to -200 MHz and 200 MHz for carrier j in Band 46. |
For Table 7.6.2.1A-0 and Table 7.6.2.1A-0b in frequency ranges 1, 2 and 3, up to exceptions per downlink are allowed for spurious response frequencies for one active uplink when measured using a step size of 1 MHz.
For Table 7.6.2.1A-0 in frequency ranges 1, 2 and 3, up to 2∙ exceptions per downlink are allowed for spurious response frequencies for two active uplinks when measured using a step size of 1 MHz. For these exceptions the requirements in clause 7.7.1A apply.
For intra-band contiguous carrier aggreagations the downlink SCC(s) shall be configured at nominal channel spacing to the PCC. For FDD, the PCC shall be configured closest to the uplink band. All downlink carriers shall be active throughout the test. The uplink output power shall be set as specified in Table 7.6.2.1A-1 with the uplink configuration set according to Table 7.3.1A-1 for the applicable carrier aggregation configuration. For UE(s) supporting one uplink carrier, the uplink configuration of the PCC shall be in accordance with Table 7.3.1-2.
The UE shall fulfil the minimum requirement in presence of an interfering signal specified in Tables 7.6.2.1A-1 and Tables 7.6.2.1A-2 being on either side of the aggregated signal. The throughput of each carrier shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annexes A.2.2, A.2.3 and A.3.2 (with one sided dynamic OCNG Pattern OP.1 FDD/TDD for the DL-signal as described in Annex A.5.1.1/A.5.2.1) with parameters specified in Tables 7.6.2.1A-1 and 7.6.2.1A-2. For operating bands with an unpaired DL part (as noted in Table 5.5-1), the requirements also apply for an SCC assigned in the unpaired part with parameters specified in Tables 7.6.2.1A-1 and 7.6.2.1A-2.
For Table 7.6.2.1A-2 in frequency range 1, 2 and 3, up to exceptions are allowed for spurious response frequencies in each assigned frequency channel when measured using a 1MHz step size. For these exceptions the requirements of subclause 7.7 Spurious response are applicable.
Table 7.6.2.1A-1: Out-of-band blocking parameters
Rx Parameter |
Units |
CA Bandwidth Class |
||||
B |
C |
D |
E |
F |
||
Pw in Transmission Bandwidth Configuration, per CC |
dBm |
REFSENS + CA Bandwidth Class specific value below |
||||
9 |
9 |
9 |
9 |
9 |
||
NOTE 1: The transmitter shall be set to 4dB below PCMAX_L,c or PCMAX_L as defined in subclause 6.2.5A. NOTE 2: Reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2. |
Table 7.6.2.1A-2: Out of band blocking
CA configuration |
Parameter |
Units |
Frequency |
||
Range 1 |
Range 2 |
Range 3 |
|||
PInterferer |
dBm |
-44 |
-30 |
-15 |
|
CA_1C, CA_2C, CA_3B, CA_3C, CA_5B, CA_7B, CA_7C, CA_8B, CA_12B, CA_23B, CA_27B, CA_28C, CA_38C, CA_39C, CA_40C, CA_40D, CA_40E, CA_40F, CA_41C, CA_41D, CA_41E, CA_41F, CA_42C1, CA_42D1, CA_42E1, CA_42F1, CA_43C1, CA_48B1, CA_48C1, CA_48D1, CA_48E1, CA_48F1, CA_66B, CA_66C, CA_66D, CA_70C |
FInterferer (CW) |
MHz |
FDL_low -15 to FDL_low -60 |
FDL_low -60 to FDL_low -85 |
FDL_low -85 to 1 MHz |
FDL_high +15 to FDL_high + 60 |
FDL_high +60 to FDL_high +85 |
FDL_high +85 to +12750 MHz |
|||
NOTE 1: The power level of the interferer (PInterferer) for this CA configuration for Range 3 shall be modified to -20 dBm for FInterferer > 2800 MHz and FInterferer < 4400 MHz. The power level of the interferer (PInterferer) for Range 3 shall be modified to -20 dBm for FInterferer > 2800 MHz and FInterferer < 4800 MHz when UE supports both E-UTRA band B42 and NR bands n77, n78. |
For intra-band non-contiguous carrier aggregation with one uplink carrier and two or more downlink sub-blocks, the out-of-band blocking requirements are defined with the uplink configuration in accordance with table 7.3.1A-3. For this uplink configuration, the UE shall meet the requirements for each sub-block as specified in subclauses 7.6.2.1 and 7.6.2.1A for one component carrier and two or more component carriers per sub-block, respectively. The requirements apply with all downlink carriers active.
For Table 7.6.2.1-2 in frequency range 1, 2 and 3, up to exceptions per assigned E-UTRA channel per sub-block of the E-UTRA CA configuration are allowed for spurious response frequencies for one active uplink when measured using a 1MHz step size. For these exceptions the requirements of subclause 7.7 spurious response are applicable.
For Table 7.6.2.1-2 in frequency range 4, up to exceptions per assigned E-UTRA channel per sub-block of the E-UTRA CA configuration are allowed for spurious response frequencies for one active uplink when measured using a 1MHz step size. For these exceptions the requirements of clause 7.7 spurious response are applicable.
For intra-band non-contiguous carrier aggregation with two uplink carriers and two or more downlink carriers, the out-of-band blocking requirements are defined with the uplink configuration of the PCC and SCC being in accordance with Table 7.3.1A-4 and powers of both carriers set to PCMAX_L,c – 7 dBm. The UE shall meet the requirements specified in subclause 7.6.2.1 for each component carrier while both downlink carriers are active.
For Table 7.6.2.1-2 in frequency range 1, 2 and 3, up to 2∙ exceptions per assigned E-UTRA channel per sub-block of the E-UTRA CA configuration are allowed for spurious response frequencies for two active uplinks in the same operating band when measured using a 1MHz step size. For these exceptions the requirements of subclause 7.7 spurious response are applicable.
For Table 7.6.2.1-2 in frequency range 4, up to 2∙ exceptions per assigned E-UTRA channel per sub-block of the E-UTRA CA configuration are allowed for spurious response frequencies for two active uplinks in the same operating band when measured using a 1MHz step size. For these exceptions the requirements of clause 7.7 spurious response are applicable.
For combinations of intra-band and inter-band carrier aggregation and the uplink assigned to one E-UTRA band, the requirement is defined with the uplink active in a band other than that supporting the downlink(s) under test. The uplink configuration shall be in accordance with Table 7.3.1A-3 when the uplink is active in the band supporting two or more non-contiguous component carriers, Table 7.3.1A-1 when the uplink is active in a band supporting two contiguous component carriers and in accordance with Table 7.3.1-2 when the uplink is active in a band supporting one carrier per band. The downlink PCC shall be configured closer to the uplink operating band than the downlink SCC(s) when the uplink is active in band(s) supporting contiguous aggregation. For the two or more non-contiguous component carriers within the same band, Pwanted in Table 7.6.2.1A-0 is set using RIBNC = 0 dB for all sub-block gaps (Table 7.3.1A-3) while a band supporting contiguously aggregated carriers the out-of-band blocking parameters in Table 7.6.2.1-1 are replaced by those specified in Table 7.6.2.1A-1. For each downlink the UE shall meet the out-of-band blocking requirements applicable for inter-band carrier aggregation with one component carrier per operating band with the following exception. For each component carrier of the E-UTRA CA Configurations with band 46 or band 49, the requirements specified in Table 7.6.2.1A-0 are replaced by those in Table 7.6.2.1A-0a. All downlink carriers shall be active throughout the tests and the requirements for the downlinks shall be met with the single uplink carrier active in each band capable of UL operation.
7.6.2.1D Minimum requirements for ProSe
The throughput shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annex A.6.2 with parameters specified in Tables 7.6.2.1D-1, 7.6.2.1D-2 and 7.6.2.1D-3.
For Table 7.6.2.1D-3 in frequency range 1, 2 and 3, up to exceptions are allowed for spurious response frequencies in each assigned frequency channel when measured using a 1MHz step size, where is the number of resource blocks in the downlink transmission bandwidth configuration (see Figure 5.6-1). For these exceptions the requirements of subclause 7.7 Spurious response are applicable.
Table 7.6.2.1D-1: Out-of-band blocking parameters for ProSe Direct Discovery
Rx Parameter |
Units |
Channel bandwidth |
|||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
||
Power in Transmission Bandwidth Configuration |
dBm |
PREFSENS_ProSe + channel bandwidth specific value below + Poffset |
|||||
6 |
6 |
7 |
9 |
||||
Poffset |
dB |
10.9 |
13.9 |
15.7 |
16.9 |
||
NOTE 2: Reference measurement channel is specified in Annex A.6.2. |
Table 7.6.2.1D-2: Out-of-band blocking parameters for ProSe Direct Communication
Rx Parameter |
Units |
Channel bandwidth |
|||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
||
Power in Transmission Bandwidth Configuration |
dBm |
PREFSENS_ProSe + channel bandwidth specific value below |
|||||
6 |
6 |
7 |
9 |
||||
NOTE 1: Reference measurement channel is specified in Annex A.6.2. |
Table 7.6.2.1D-3: Out of band blocking for ProSe
E-UTRA ProSe band |
Parameter |
Units |
Frequency |
||
Range 1 |
Range 2 |
Range 3 |
|||
PInterferer |
dBm |
-44 |
-30 |
-15 |
|
2,3,4,7,14, 20,26,28,31,72 |
FInterferer (CW) |
MHz |
FDL_low -15 to FDL_low -60 |
FDL_low -60 to FDL_low -85 |
FDL_low -85 to 1 MHz |
FDL_high +15 to FDL_high + 60 |
FDL_high +60 to FDL_high +85 |
FDL_high +85 to +12750 MHz |
|||
NOTE 1: For the UE which supports both Band 11 and Band 21 the out of blocking is FFS. |
7.6.2.1F Minimum requirements for category NB1 and NB2
The category NB1 and NB2 UE throughput shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annexes A.3.2 with parameters specified in Table 7.6.2.1F-1.
For Table 7.6.2.1F-1 in frequency range 1, 2 and 3, up to 24 exceptions are allowed for spurious response frequencies in each assigned frequency channel when measured using a 1MHz step size. For these exceptions the requirements of subclause 7.7.1F spurious response are applicable.
Table 7.6.2.1F-1: Out-of-band blocking parameters for category NB1 and NB2 UE
Parameter |
Units |
Frequency |
||
Range 1 |
Range 2 |
Range 3 |
||
Pwanted |
dBm |
REFSENS + 6 dB |
||
Pinterferer (CW) |
dBm |
-44 |
-30 |
-15 |
Finterferer range |
MHz |
FDL_low – 15 to FDL_low – 60 |
FDL_low – 60 to FDL_low – 85 |
FDL_low – 85 to 1 MHz |
MHz |
FDL_high + 15 to FDL_high + 60 |
FDL_high + 60 to FDL_high + 85 |
FDL_high + 85 to 12750 MHz |
|
NOTE 1: For operating bands which downlink band frequency range is between 617 MHz < f < 1 GHz the power level of the interferer (PInterferer) for Range 3 shall be modified to: -18 dBm for the frequency range which is bounded by FDL_low – 150 MHz of the lowest band that UE supports in frequency range 617 MHz < f < 1 GHz and FDL_high + 150 MHz of the highest band that UE supports in frequency range 617 MHz < f < 1 GHz. NOTE 2: For operating bands which downlink band frequency range is between 1475.9 MHz < f < 2690 MHz the power level of the interferer (PInterferer) for Range 3 shall be modified to: -20 dBm for the frequency range which is bounded by FDL_low– 200 MHz of the lowest band that UE supports in frequency range 1475.9 MHz < f < 2690 MHz and FDL_high + 200 MHz of the highest band that UE supports supports in frequency range 1475.9 MHz < f < 2690 MHz. NOTE 3: For operating bands which downlink band frequency range is between 460 MHz < f < 467.5 MHz the power level of the interferer (PInterferer) for Range 3 shall be modified to: – 18 dBm for the frequency range which is bounded by FDL_low – 150 MHz of the lowest band that UE supports in frequency range 460 MHz < f < 467.5 0 MHz and FDL_high + 150 MHz of the highest band that UE supports supports in frequency range 460 MHz < f < 467.5. NOTE 4: The power level of the interferer (PInterferer) for Range 3 shall be modified to -20 dBm for FInterferer > 2800 MHz and FInterferer < 4400 MHz. |
7.6.2.1G Minimum requirements for V2X
The throughput shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annex A.8.2 with parameters specified in Tables 7.6.2.1G-1, 7.6.2.1G-2.
For Table 7.6.2.1G-2 in frequency range 1, 2 and 3, up to exceptions are allowed for spurious response frequencies in each assigned frequency channel when measured using a 1MHz step size, where is the number of resource blocks in the downlink transmission bandwidth configuration (see Figure 5.6-1). For these exceptions the requirements of subclause 7.7 spurious response are applicable.
Table 7.6.2.1G-1: Out-of-band blocking parameters
Rx Parameter |
Units |
Channel bandwidth |
|||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
||
Power in Transmission Bandwidth Configuration |
dBm |
PREFSENS_V2X + channel bandwidth specific value below |
|||||
6 |
9 |
||||||
NOTE 1: Reference measurement channel is specified in Annex A.8.2. |
Table 7.6.2.1G-2: Out of band blocking
E-UTRA V2X band |
Parameter |
Units |
Frequency |
||
Range 1 |
Range 2 |
Range 3 |
|||
PInterferer |
dBm |
-44 |
-30 |
-15 |
|
47 |
FInterferer (CW) |
MHz |
FDL_low -30 to FDL_low -60 |
FDL_low -60 to FDL_low -85 |
FDL_low -85 to 1 MHz |
FDL_high +30 to FDL_high + 60 |
FDL_high +60 to FDL_high +85 |
FDL_high +85 to +12750 MHz |
|||
NOTE: The power level of the interferer (PInterferer) for Range 3 shall be modified to -20 dBm for FInterferer > 4400 MHz. |
When UE is configured for simultaneous E-UTRA V2X sidelink and E-UTRA downlink reception for inter-band E-UTRA V2X / E-UTRA bands specified in Table 5.5G-2, the requirements in subclause 7.6.2.1G apply for the E-UTRA V2X sidelink reception and the requirements in subclause 7.6.2.1 apply for the E-UTRA downlink reception while all downlink carriers are active.
For intra-band contiguous multi-carrier operation, the V2X UE throughput shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annex A.8.2 with parameters specified in Tables 7.6.2.1G-3 and 7.6.2.1G-4.
For Table 7.6.2.1G-4 in frequency range 1, 2 and 3, up to exceptions are allowed for spurious response frequencies in each assigned frequency channel when measured using a 1MHz step size. For these exceptions the requirements of subclause 7.7 spurious response are applicable.
Table 7.6.2.1G-3: Out-of-band blocking parameters for intra-band contiguous multi-carrier for V2X UE
Rx Parameter |
Units |
V2X Bandwidth Class |
||||
B |
C/ C1 |
D |
E |
F |
||
Pw in Transmission Bandwidth Configuration, per CC |
dBm |
REFSENS + V2X Bandwidth Class specific value below |
||||
9 |
9 |
Table 7.6.2.1G-4: Out of band blocking for intra-band contiguous multi-carrier for V2X UE
V2X multi-carrier configuration |
Parameter |
Units |
Frequency |
||
Range 1 |
Range 2 |
Range 3 |
|||
PInterferer |
dBm |
-44 |
-30 |
-15 |
|
V2X_47B, V2X_47C, V2X_47C1 |
FInterferer (CW) |
MHz |
FDL_low -30 to FDL_low -60 |
FDL_low -60 to FDL_low -85 |
FDL_low -85 to 1 MHz |
FDL_high +30 to FDL_high + 60 |
FDL_high +60 to FDL_high +85 |
FDL_high +85 to +12750 MHz |
|||
NOTE 1: The power level of the interferer (PInterferer) for Range 3 shall be modified to -20 dBm for FInterferer > 4400 MHz. NOTE 2: The requirement is applied for multi-carrier intra-band con-current receptions when 2 carrier transmissions are activated at the same time. |
7.6.3 Narrow band blocking
This requirement is measure of a receiver’s ability to receive a E-UTRA signal at its assigned channel frequency in the presence of an unwanted narrow band CW interferer at a frequency, which is less than the nominal channel spacing.
7.6.3.1 Minimum requirements
The relative throughput shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annexes A.2.2, A.2.3 and A.3.2 (with one sided dynamic OCNG Pattern OP.1 FDD/TDD for the DL-signal as described in Annex A.5.1.1/A.5.2.1) with parameters specified in Table 7.6.3.1-1. For operating bands with an unpaired DL part (as noted in Table 5.5-1), the requirements only apply for carriers assigned in the paired part.
Table 7.6.3.1-1: Narrow-band blocking
Parameter |
Unit |
Channel Bandwidth |
|||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
||
Pw |
dBm |
PREFSENS + channel-bandwidth specific value below |
|||||
22 |
18 |
16 |
13 |
14 |
16 |
||
Puw (CW) |
dBm |
-55 |
-55 |
-55 |
-55 |
-55 |
-55 |
Fuw (offset for f = 15 kHz) |
MHz |
0.9075 |
1.7025 |
2.7075 |
5.2125 |
7.7025 |
10.2075 |
Fuw (offset for f = 7.5 kHz) |
MHz |
||||||
NOTE 1: The transmitter shall be set a 4 dB below PCMAX_L at the minimum uplink configuration specified in Table 7.3.1-2 with PCMAX_L as defined in subclause 6.2.5. NOTE 2: Reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. NOTE 3: The PREFSENS power level is specified in Table 7.3.1-1 and Table 7.3.1-1a for two and four antenna ports, respectively. NOTE 4: For DL category M1 and M2 UE, the reference sensitivity for category M1 in table 7.3.1E-3 and category M2 in Table 7.3.1E-8 should be used as PREFSENS for Pw. NOTE5: For DL category M1 and M2 UE, the parameters for the applicable channel bandwidth apply. NOTE6: For DL category M1 UE, the parameter, Pw, for all the channel bandwidth will be PREFSENS +22 dBm. NOTE7: For DL category M2 UE, the parameter, Pw, for all channel bandwidths greater than 3 MHz will be PREFSENS +16 dBm. |
For the UE which supports inter-band CA configuration in Table 7.3.1-1A, PUW power defined in Table 7.6.3.1-1 is increased by the amount given by ΔRIB,c in Table 7.3.1-1A.
7.6.3.1A Minimum requirements for CA
For inter-band carrier aggregation with one component carrier per operating band and the uplink assigned to one E-UTRA band the narrow-band blocking requirements are defined with the uplink active on the band(s) other than the band whose downlink is being tested. The UE shall meet the requirements specified in subclause 7.6.3.1 for each component carrier while all downlink carriers are active. For E-UTRA CA configurations including an operating band without uplink band or an operating band with an unpaired DL part (as noted in Table 5.5-1), the requirements for all downlinks shall be met with the single uplink carrier active in each band capable of UL operation. For E-UTRA CA configurations listed in Table 7.3.1A-0a under conditions for which reference sensitivity for the operating band being tested is N/A, the narrow-band blocking requirements of subclause 7.6.3.1A do not apply. For E-UTRA CA configurations with a component carrier assigned in Band 46, narrow-band blocking requirements do not apply in the presence of a narrow-band interferer in Band 46.
For intra-band contiguous carrier aggregation the downlink SCC(s) shall be configured at nominal channel spacing to the PCC. For FDD, the PCC shall be configured closest to the uplink band. All downlink carriers shall be active throughout the test. The uplink output power shall be set as specified in Table 7.6.3.1A-1 with the uplink configuration set according to Table 7.3.1A-1 for the applicable carrier aggregation configuration. For UE(s) supporting one uplink, the uplink configuration of the PCC shall be in accordance with Table 7.3.1-2. The UE shall fulfil the minimum requirement in presence of an interfering signal specified in Table 7.6.3.1A-1 being on either side of the aggregated signal. The throughput of each carrier shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annexes A.2.2, A.2.3 and A.3.2 (with one sided dynamic OCNG Pattern OP.1 FDD/TDD for the DL-signal as described in Annex A.5.1.1/A.5.2.1) with parameters specified in Table 7.6.3.1A-1. For operating bands with an unpaired DL part (as noted in Table 5.5-1), the requirements also apply for an SCC assigned in the unpaired part with parameters specified in Table 7.6.3.1A-1.
For intra-band non-contiguous carrier aggregation with one uplink carrier and two or more downlink sub-blocks, the narrow band blocking requirements are defined with the uplink configuration in accordance with Table 7.3.1A-3. For this uplink configuration, the UE shall meet the requirements for each sub-block as specified in subclauses 7.6.3.1 and 7.6.3.1A for one component carrier and two component carriers per sub-block, respectively. The requirements apply for in-gap and out-of-gap interferers while all downlink carriers are active.
Table 7.6.3.1A-1: Narrow-band blocking
Parameter |
Unit |
CA Bandwidth Class |
||||
B |
C |
D |
E |
F |
||
Pw in Transmission Bandwidth Configuration, per CC |
dBm |
REFSENS + CA Bandwidth Class specific value below |
||||
16 |
164 |
16 |
16 |
16 |
||
Puw (CW) |
dBm |
-55 |
-55 |
-55 |
-55 |
-55 |
Fuw (offset for f = 15 kHz) |
MHz |
– Foffset – 0.2 / + Foffset + 0.2 |
– Foffset – 0.2 / + Foffset + 0.2 |
– Foffset – 0.2 / + Foffset + 0.2 |
– Foffset – 0.2 / + Foffset + 0.2 |
– Foffset – 0.2 / + Foffset + 0.2 |
Fuw (offset for f = 7.5 kHz) |
MHz |
|||||
NOTE 1: The transmitter shall be set to 4dB below PCMAX_L,c or PCMAX_L as defined in subclause 6.2.5A. NOTE 2: Reference measurement channel is specified in Annex A.3.2 with one sided dynamic OCNG Pattern OP.1 FDD/TDD as described in Annex A.5.1.1/A.5.2.1. NOTE 3: The Fuw (offset) is the frequency separation of the center frequency of the carrier closest to the interferer and the center frequency of the interferer and shall be further adjusted to MHz to be offset from the sub-carrier raster. NOTE 4: The requirement is applied for the band combinations whose component carriers’ BW≥5 MHz. |
For combinations of intra-band and inter-band carrier aggregation and one uplink carrier assigned to one E-UTRA band, the requirement is defined with the uplink active in a band other than that supporting the downlink(s) under test. The uplink configuration shall be in accordance with Table 7.3.1A-3 when the uplink is active in the band supporting two or more non-contiguous component carriers, Table 7.3.1A-1 when the uplink is active in a band supporting two contiguous component carriers and in accordance with Table 7.3.1-2 when the uplink is active in a band supporting one carrier per band. The downlink PCC shall be configured closer to the uplink operating band than the downlink SCC(s) when the uplink is active in band(s) supporting contiguous aggregation. For these uplink configurations, the UE shall meet the narrow-band blocking requirements for intra-band non-contiguous carrier aggregation with RIBNC = 0 dB for all sub-block gaps (Table 7.3.1A-3) for the two or more non-contiguous downlink sub-blocks, the requirements for intra-band contiguous carrier aggregation for the contiguously aggregated downlink carriers and for any remaining component carrier(s) the requirements specified in subclause 7.6.3. For E-UTRA CA configurations with component carriers assigned in Band 46, narrow-band blocking requirements do not apply in the presence of a narrow-band interferer in Band 46. All downlink carriers shall be active throughout the tests and the requirements for the downlinks shall be met with the single uplink carrier active in each band capable of UL operation.
7.6.3.1D Minimum requirements for ProSe
The relative throughput shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annex A.6.2 with parameters specified in Table 7.6.3.1D-1 and Table 7.6.3.1D-2.
Table 7.6.3.1D-1: Narrow-band blocking for ProSe Direct Discovery
Parameter |
Unit |
Channel Bandwidth |
|||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
||
Pw |
dBm |
PREFSENS_ProSe + channel-bandwidth specific value below + Poffset |
|||||
16 |
13 |
14 |
16 |
||||
Puw (CW) |
dBm |
-55 |
-55 |
-55 |
-55 |
||
Poffset |
dB |
10.9 |
13.9 |
15.7 |
16.9 |
||
Fuw (offset for f = 15 kHz) |
MHz |
2.7075 |
5.2125 |
7.7025 |
10.2075 |
||
Fuw (offset for f = 7.5 kHz) |
MHz |
||||||
NOTE 1: Reference measurement channel is specified in Annex A.6.2. |
Table 7.6.3.1D-2: Narrow-band blocking for ProSe Direct Communication
Parameter |
Unit |
Channel Bandwidth |
|||||
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
||
Pw |
dBm |
PREFSENS_ProSe + channel-bandwidth specific value below |
|||||
16 |
13 |
14 |
16 |
||||
Puw (CW) |
dBm |
-55 |
-55 |
-55 |
-55 |
||
Fuw (offset for f = 15 kHz) |
MHz |
2.7075 |
5.2125 |
7.7025 |
10.2075 |
||
Fuw (offset for f = 7.5 kHz) |
MHz |
||||||
NOTE 1: Reference measurement channel is specified in Annex A.6.2. |
For the UE which supports inter-band CA configuration in Table 7.3.1-1A, PUW power defined in Table 7.6.3.1D-1 and Table 7.6.3.1D-2 is increased by the amount given by ΔRIB,c in Table 7.3.1-1A.