7.3.1D Minimum requirements (QPSK) for ProSe
36.1013GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Release 18TSUser Equipment (UE) radio transmission and reception
When UE is configured for E-UTRA ProSe reception non-concurrent with E-UTRA uplink transmissions for E-UTRA ProSe operating bands specified in Table 5.5D-1, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annexes A.6.2 with parameters specified in Table 7.3.1D-1 and Table 7.3.1D-2.
Table 7.3.1D-1: Reference sensitivity for ProSe Direct Discovery QPSK PREFSENS
Channel bandwidth |
|||||||
E-UTRA ProSe Band |
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
Duplex Mode |
2 |
-104.1 |
-104.1 |
-104.1 |
-104.1 |
HD |
||
3 |
-103.1 |
-103.1 |
-103.1 |
-103.1 |
HD |
||
4 |
-106.1 |
-106.1 |
-106.1 |
-106.1 |
HD |
||
7 |
-103.8 |
-103.8 |
-103.8 |
-103.8 |
HD |
||
14 |
-103.1 |
-103.1 |
HD |
||||
20 |
-103.2 |
-103.2 |
-102.2 |
-102.2 |
HD |
||
26 |
-103.55 |
-103.5 5 |
-103.5 5 |
HD |
|||
28 |
-104.4 |
-104.4 |
-104.4 |
-102.9 |
HD |
||
31 |
-99.5 |
HD |
|||||
68 |
-104.4 |
-104.4 |
-104.4 |
HD |
|||
72 |
-99.5 |
HD |
|||||
NOTE 1: Reference measurement channel is A.6.2 NOTE 2: The signal power is specified per port NOTE 3: For the UE which supports both Band 3 and Band 9 the reference sensitivity level is FFS. NOTE 4: For the UE which supports both Band 11 and Band 21 the reference sensitivity level is FFS. NOTE 5: 5 indicates that the requirement is modified by -0.5 dB when the carrier frequency of the assigned E-UTRA channel bandwidth is within 865-894 MHz. NOTE 6: For a UE that support both Band 18 and Band 26, the reference sensitivity level for Band 26 applies for the applicable channel bandwidths. |
Table 7.3.1D-2: Reference sensitivity for ProSe Direct Communication QPSK PREFSENS
Channel bandwidth |
|||||||
E-UTRA ProSe Band |
1.4 MHz |
3 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
Duplex Mode |
3 |
-97.6 |
HD |
|||||
7 |
-98.3 |
HD |
|||||
14 |
-97.6 |
HD |
|||||
20 |
-97.7 |
HD |
|||||
26 |
-98.0 5 |
HD |
|||||
28 |
-98.9 |
HD |
|||||
31 |
-96.7 |
HD |
|||||
68 |
-101.7 |
-98.9 |
HD |
||||
72 |
-96.7 |
HD |
|||||
NOTE 1: Reference measurement channel is A.6.2 NOTE 2: The signal power is specified per port NOTE 3: For the UE which supports both Band 3 and Band 9 the reference sensitivity level is FFS. NOTE 4: For the UE which supports both Band 11 and Band 21 the reference sensitivity level is FFS. NOTE 5: 5 indicates that the requirement is modified by -0.5 dB when the carrier frequency of the assigned E-UTRA channel bandwidth is within 865-894 MHz. NOTE 6: For a UE that support both Band 18 and Band 26, the reference sensitivity level for Band 26 applies for the applicable channel bandwidths. |
NOTE: Table 7.3.1D-1/ Table 7.3.1D-2 is intended for conformance tests and does not necessarily reflect the operational conditions of the network, where the number of allocated resource blocks will be practically constrained by other factors.
For the UE which supports ProSe in an operating band as specified in Section 5.5D, and the UE also supports a E-UTRA downlink inter-band carrier aggregation configuration in Table 7.3.1-1A or Table 7.3.1-1B, the minimum requirement for reference sensitivity in Table 7.3.1D-1 and Table 7.3.1D-2 shall be increased by the amount given in ΔRIB,c in Table 7.3.1-1A and Table 7.3.1-1B for the corresponding E-UTRA ProSe band.
When UE is configured for E-UTRA ProSe reception on PCC for the inter-band E-UTRA ProSe / E-UTRA bands specified in Table 5.5D-2, there are no further requirements for reference sensitivity beyond those specified above when only PCC is configured in Table 7.3.1D-1 and Table 7.3.1D-2.
When UE is configured for E-UTRA ProSe reception on SCC or a non-serving carrier concurrent with E-UTRA uplink for inter-band E-UTRA ProSe / E-UTRA bands specified in Table 5.5D-2, E-UTRA ProSe throughput shall be ≥ 95% of the maximum throughput of the reference measurement channels as specified in Annexes A.6.2 with parameters specified in Table 7.3.1D-1 and Table 7.3.1D-2. The reference sensitivity is defined to be met with E-UTRA uplink assigned to one band (that differs from the ProSe operating band) and all E-UTRA downlink carriers active. The E-UTRA uplink resource blocks shall be located as close as possible to E-UTRA ProSe operating band but confined within the transmission bandwidth configuration for the channel bandwidth (Table 5.6-1). The uplink configuration for the E-UTRA operating band is specified in Table 7.3.1D-3.
NOTE: The E-UTRA uplink channel bandwidth and transmission bandwidth specified in this Table 7.3.1D-3 are intended for conformance tests and does not restrict the operating conditions of the network.
Table 7.3.1D-3: Uplink configuration for E-UTRA band / E-UTRA CA band
Inter-band E-UTRA ProSe/E-UTRA configuration |
E-UTRA UL band / Channel BW / NRB / Duplex mode |
||||
E-UTRA ProSe band |
E-UTRA band / E-UTRA CA band |
E-UTRA UL band |
Channel Bandwidth (MHz) |
NRB |
Duplex Mode |
2 |
4 |
4 |
5 |
25 |
FDD |
2 |
CA_2-4 |
4 |
5 |
25 |
FDD |
28 |
1 |
1 |
5 |
25 |
FDD |
28 |
CA_1-28 |
1 |
5 |
25 |
FDD |
NOTE 1: For E-UTRA ProSe reception on SCC, the channel bandwith of the E-UTRA downlink SCC is set same as the ProSe channel bandwidth for which reference sensitivity is being measured. |