6.6.3 Spurious emissions

36.1013GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Release 18TSUser Equipment (UE) radio transmission and reception

Spurious emissions are emissions which are caused by unwanted transmitter effects such as harmonics emission, parasitic emissions, intermodulation products and frequency conversion products, but exclude out of band emissions unless otherwise stated. The spurious emission limits are specified in terms of general requirements inline with SM.329 [2] and E-UTRA operating band requirement to address UE co-existence.

To improve measurement accuracy, sensitivity and efficiency, the resolution bandwidth may be smaller than the measurement bandwidth. When the resolution bandwidth is smaller than the measurement bandwidth, the result should be integrated over the measurement bandwidth in order to obtain the equivalent noise bandwidth of the measurement bandwidth.

6.6.3.1 Minimum requirements

Unless otherwise stated, the spurious emission limits apply for the frequency ranges that are more than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth. The spurious emission limits in Table 6.6.3.1-2 apply for all transmitter band configurations (NRB) and channel bandwidths.

NOTE: For measurement conditions at the edge of each frequency range, the lowest frequency of the measurement position in each frequency range should be set at the lowest boundary of the frequency range plus MBW/2. The highest frequency of the measurement position in each frequency range should be set at the highest boundary of the frequency range minus MBW/2. MBW denotes the measurement bandwidth defined for the protected band.

Table 6.6.3.1-1: Boundary between E-UTRA out of band and spurious emission domain

Channel bandwidth

1.4

MHz

3.0

MHz

5

MHz

10

MHz

15

MHz

20

MHz

OOB boundary FOOB (MHz)

2.8

6

10

15

20

25

Table 6.6.3.1-2: Spurious emissions limits

Frequency Range

Maximum Level

Measurement bandwidth

NOTE

9 kHz ≤ f < 150 kHz

-36 dBm

1 kHz

150 kHz ≤ f < 30 MHz

-36 dBm

10 kHz

30 MHz ≤ f < 1000 MHz

-36 dBm

100 kHz

1 GHz ≤ f < 12.75 GHz

-30 dBm

1 MHz

12.75 GHz ≤ f < 5th harmonic of the upper frequency edge of the UL operating band in GHz

-30 dBm

1 MHz

1

12.75 GHz < f < 26GHz

-30dBm

1MHz

2

NOTE 1: Applies for Band 22, Band 42, Band 43 and Band 48.

NOTE 2: Applies for Band 46 and Band 47.

6.6.3.1A Minimum requirements for CA

This clause specifies the spurious emission requirements for carrier aggregation.

NOTE: For measurement conditions at the edge of each frequency range, the lowest frequency of the measurement position in each frequency range should be set at the lowest boundary of the frequency range plus MBW/2. The highest frequency of the measurement position in each frequency range should be set at the highest boundary of the frequency range minus MBW/2. MBW denotes the measurement bandwidth defined for the protected band.

For inter-band carrier aggregation with one component carrier per operating band and the uplink active in two E-UTRA bands, the spurious emission requirement Table 6.6.3.1-2 apply for the frequency ranges that are more than FOOB as defined in Table 6.6.3.1-1 away from edges of the assigned channel bandwidth on a component carrier. If for some frequency a spurious emission requirement of individual component carrier overlaps with the spectrum emission mask or channel bandwidth of another component carrier then it does not apply.

NOTE: For inter-band carrier aggregation with uplink assigned to two E-UTRA bands the requirements in Table 6.6.3.1-2 could be verified by measuring spurious emissions at the specific frequencies where second and third order intermodulation products generated by the two transmitted carriers can occur; in that case, the requirements for remaining applicable frequencies in Table 6.6.3.1-2 would be considered to be verified by the measurements verifying the one uplink inter-band CA spurious emission requirement.

For intra-band contiguous carrier aggregation the spurious emission limits apply for the frequency ranges that are more than FOOB (MHz) in Table 6.6.3.1A-1 from the edge of the aggregated channel bandwidth (Table 5.6A-1). For frequencies ΔfOOB greater than FOOB as specified in Table 6.6.3.1A-1the spurious emission requirements in Table 6.6.3.1-2 are applicable.

Table 6.6.3.1A-1: Boundary between E-UTRA out of band and spurious emission domain for intra-band contiguous carrier aggregation

CA Bandwidth Class

OOB boundary FOOB

(MHz)

A

Table 6.6.3.1-1

B

BWChannel_CA + 5

C

BWChannel_CA + 5

For intra-band non-contiguous carrier aggregation transmission the spurious emission requirement is defined as a composite spurious emission requirement. Composite spurious emission requirement applies to frequency ranges that are more than FOOB away from the edges of the sub-blocks. Composite spurious emission requirement is defined as follows

a) Composite spurious emission requirement is a combination of individual sub-block spurious emission requirements

b) In case the sub-block consist of one component carrier the sub-lock spurious emission requirement and FOOB are defined in subclause 6.6.3.1

c) If for some frequency an individual sub-block spurious emission requirement overlaps with the general spectrum emission mask or the sub-block bandwidth of another sub-block then it does not apply

For combinations of intra-band and inter-band carrier aggregation with three uplink component carriers (up to two contiguously aggregated carriers per band), the spurious emission requirememnt is defined as follows. For the E-UTRA band supporting one component carrier the requirements in Table 6.6.3.1-2 apply for frequency ranges that are more than FOOB (MHz) from the edges of assigned channel bandwidth as defined in Table 6.6.3.1-1. For the E-UTRA band supporting two contiguous component carriers the requirements in Table 6.6.3.1-2 apply for frequency ranges that are more than FOOB (MHz) from the edges of assigned aggregated channel bandwidth as defined in Table 6.6.3.1A-1. If for some frequency a spurious emission requirement of a single component carrier or two contiguous component carriers overlap with the spurious emission requirement or channel bandwidth of another component carrier or two contiguously aggregated carriers then it does not apply.

6.6.3.2 Spurious emission band UE co-existence

This clause specifies the requirements for the specified E-UTRA band, for coexistence with protected bands.

NOTE: For measurement conditions at the edge of each frequency range, the lowest frequency of the measurement position in each frequency range should be set at the lowest boundary of the frequency range plus MBW/2. The highest frequency of the measurement position in each frequency range should be set at the highest boundary of the frequency range minus MBW/2. MBW denotes the measurement bandwidth defined for the protected band.

Table 6.6.3.2-1: Requirements

E-UTRA Band

Spurious emission

Protected band

Frequency range (MHz)

Maximum Level (dBm)

MBW (MHz)

NOTE

1

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 20, 21, 22, 26, 27, 28, 31, 32, 38, 40, 41, 42, 43, 44, 45, 50, 51, 52, 65, 67, 68, 69, 72, 73, 74, 75, 76, 87, 88

NR Band n78, n79, n100, n101

FDL_low

FDL_high

-50

1

E-UTRA Band 34

FDL_low

FDL_high

-50

1

15

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

1880

1895

-40

1

15, 27

Frequency range

1895

1915

-15.5

5

15, 26, 27

Frequency range

1915

1920

+1.6

5

15, 26, 27, 44

2

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 27, 28, 29, 30, 41, 42, 50, 51, 53, 54, 66, 70, 71, 74, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

15

E-UTRA Band 43, 48

NR Band n77

FDL_low

FDL_high

-50

1

2

3

E-UTRA Band 1, 5, 7, 8, 11, 18, 19, 20, 21, 26, 27, 28, 31, 32, 33, 34, 38, 39, 40, 41, 43, 44, 45, 50, 51, 65, 67, 68, 69, 72, 73,74, 75, 76, 87, 88

NR Band n79, n100, n101

FDL_low

FDL_high

-50

1

E-UTRA Band 3

FDL_low

FDL_high

-50

1

15

E-UTRA Band 22, 42, 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

4

E-UTRA Band 2, 4, 5, 7, 12, 13, 14, 17, 24, 25, 26, 27, 28, 29, 30, 41, 43, 48, 50, 51, 53, 66, 70, 71, 74, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 42,

NR Band n77

FDL_low

FDL_high

-50

1

2

5

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 12, 13, 14, 17, 24, 25, 28, 29, 30, 31, 34, 38, 40, 42, 43, 45, 48, 50, 51, 54, 65, 66, 70, 71, 73, 74, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 26

859

869

-27

1

E-UTRA Band 41, 52, 53

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 18, 19

FDL_low

FDL_high

-40

1

39

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

39

Frequency range

1884.5

1915.7

-41

0.3

8, 39

6

E-UTRA Band 1, 9, 11, 34

FDL_low

FDL_high

-50

1

Frequency range

860

875

-37

1

Frequency range

875

895

-50

1

Frequency range

1884.5

1919.6

-41

0.3

7

1884.5

1915.7

8

7

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 12, 13, 14, 17, 20, 22, 26, 27, 28, 29, 30, 31, 32, 33, 34, 40, 42, 43, 50, 51, 52, 65, 66, 67, 68, 72, 74, 75, 76, 85, 87, 88, 103

NR Band n77, n78, n100, n101

FDL_low

FDL_high

-50

1

NR Band n79

FDL_low

FDL_high

-50

1

2

Frequency range

2570

2575

+1.6

5

15, 21, 26

Frequency range

2575

2595

-15.5

5

15, 21, 26

Frequency range

2595

2620

-40

1

15, 21

8

E-UTRA Band 1, 20, 28, 31, 32, 33, 34, 38, 39, 40, 45, 50, 51, 65, 67, 68, 69, 72, 73, 74, 75, 76, 87, 88

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA band 3, 7, 22, 41, 42, 43, 52, 54

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

15

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

23

Frequency range

860

890

-40

1

15, 23

Frequency range

1884.5

1915.7

-41

0.3

8, 23

9

E-UTRA Band 1, 3, 11, 18, 19, 21, 26, 28, 34

FDL_low

FDL_high

-50

1

E-UTRA Band 42

FDL_low

FDL_high

-50

1

2

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

8

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

10

E-UTRA Band 2, 4, 5, 10, 12, 13, 14, 17, 24, 25, 26, 27, 28, 29, 30, 41, 43, 54, 66, 70, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 22, 42,

NR Band n77

FDL_low

FDL_high

-50

1

2

11

E-UTRA Band 1, 3, 11, 18, 19, 21, 28, 34, 40, 42, 65

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

8

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

12

E-UTRA Band 2, 5, 13, 14, 17, 24, 25, 26, 27, 30, 41, 53, 54, 70, 71, 74, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 48, 50, 51, 66

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 12, 85

FDL_low

FDL_high

-50

1

15

13

E-UTRA Band 2, 4, 5, 12, 13, 17, 25, 26, 27, 29, 41, 48, 50, 51, 53, 54, 66, 70, 71, 74, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 14

FDL_low

FDL_high

-50

1

15

E-UTRA Band 24, 30,

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

15

Frequency range

799

805

-35

0.00625

15

14

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 23, 24, 25, 26, 27, 29, 30, 41, 48, 53, 54, 66, 70, 71, 85, 103

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

12, 15

Frequency range

799

805

-35

0.00625

12, 15

17

E-UTRA Band 2, 5, 13, 14, 17, 24, 25, 26, 27, 30, 41, 71, 74, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 48, 50, 51, 53, 54, 66, 70,

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 12, 48, 85

FDL_low

FDL_high

-50

1

15

18

E-UTRA Band 1, 3, 11, 21, 34, 40, 42, 65

NR Band n79

FDL_low

FDL_high

-50

1

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

758

799

-50

1

Frequency range

799

803

-40

1

15

Frequency range

860

890

-40

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

8

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

19

E-UTRA Band 1, 3, 11, 21, 28, 34, 40, 42, 65

NR Band n79

FDL_low

FDL_high

-50

1

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

8

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

20

E-UTRA Band 1, 3, 7, 8, 22, 31, 32, 33, 34, 40, 43, 50, 51, 65, 67, 68, 72, 74, 75, 76, 87, 88

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA Band 20

FDL_low

FDL_high

-50

1

15

E-UTRA Band 38, 42, 52, 69

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

758

788

-50

1

21

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 42, 65

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

8

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

22

E-UTRA Band 1, 3, 7, 8, 20, 26, 27, 28, 31, 32, 33, 34, 38, 39, 40, 43, 65, 67, 68, 69, 72, 75, 76, 87, 88

NR Band n100, n101

FDL_low

FDL_high

-50

1

Frequency range

3510

3525

-40

1

15

Frequency range

3525

3590

-50

1

23

E-UTRA Band 4, 5, 12, 13, 14, 17, 23, 24, 26, 27, 29, 30, 41, 54, 66, 103

FDL_low

FDL_high

-50

1

24

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 26, 29, 30, 41, 48, 66, 70, 71, 85, 103

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

2

25

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 27, 28, 29, 30, 41, 42, 53, 54, 66, 70, 71, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 2

FDL_low

FDL_high

-50

1

15

E-UTRA Band 25

FDL_low

FDL_high

-50

1

15

E-UTRA Band 43, 48

NR Band n77

FDL_low

FDL_high

-50

1

2

26

E-UTRA Band 1, 2, 3, 4, 5, 11, 12, 13, 14, 17, 18,19, 21, 24, 25, 26, 29, 30, 31, 34, 39, 40, 42, 43, 48, 50, 51, 54, 65, 66, 70, 71, 73,74, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 41, 53

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

703

799

-50

1

Frequency range

799

803

-40

1

15

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

8

27

E-UTRA Band 1, 2, 3, 4, 5, 7, 12, 13, 14, 17, 25, 26, 27, 29, 30, 31, 38, 40, 41, 42, 43, 65, 66, 73, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 28

FDL_low

790

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

799

805

-35

0.00625

28

E-UTRA Band 1, 4, 22, 32, 42, 43, 50, 51, 65, 66, 73, 74, 75, 76

NR Band n77, n78, n100, n101

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

19, 25

E-UTRA Band 2, 3, 5, 7, 8, 18, 19, 20, 25, 26, 27, 31, 34, 38, 40, 41, 52, 72, 87, 88

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

19, 24

Frequency range

470

694

-42

8

15, 35

Frequency range

470

710

-26.2

6

34

Frequency range

662

694

-26.2

6

15

Frequency range

758

773

-32

1

15

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

8, 19

30

E-UTRA Band 2, 4, 5, 7, 12, 13, 14, 17, 24, 25, 26, 27, 29, 30, 38, 41, 48, 53, 54, 66, 70, 71, 85, 103

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

2

31

E-UTRA Band 1, 5, 7, 8, 20, 22, 26, 27, 28, 31, 32, 33, 34, 38, 40, 42, 43, 50, 51, 52, 65, 67, 68, 69, 74, 75, 76, 87, 88

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA Band 3

FDL_low

FDL_high

-50

1

2

Frequency range

470

694

-42

8

33

E-UTRA Band 1, 7, 8, 20, 22, 28, 31, 32, 34, 38, 40, 42, 52, 65, 67, 69, 72, 73, 75, 76, 87, 88

NR Band n100, n101

FDL_low

FDL_high

-50

1

5

E-UTRA Band 43

FDL_low

FDL_high

-50

1

2

E-UTRA Band 3

FDL_low

FDL_high

-50

1

15

34

E-UTRA Band 1, 3, 7, 8, 11, 18, 19, 20, 21, 22, 26, 28, 31, 32, 33, 38,39, 40, 41, 42, 43, 44, 45, 50, 51, 52, 65, 67, 69, 72, 73, 74, 75, 76, 87, 88

NR Band n78, n79, n100, n101

FDL_low

FDL_high

-50

1

5

NR Band n77

FDL_low

FDL_high

-50

1

2, 5

Frequency range

1884.5

1915.7

-41

0.3

8

35

36

37

38

E-UTRA Band 1, 2, 3, 4, 5, 8, 12, 13, 14, 17, 20, 22, 27, 28, 29, 30, 31, 32, 33, 34, 40, 42, 43, 50, 51, 52, 65, 66, 67, 68, 72, 74, 75, 76, 85, 87, 88, 103

NR Band n77, n78, n79, n100, n101

FDL_low

FDL_high

-50

1

Frequency range

2620

2645

-15.5

5

15, 22, 26

Frequency range

2645

2690

-40

1

15, 22

39

E-UTRA Band 1, 8, 22, 26, 28, 34, 40, 41, 42, 44, 45, 50, 51, 52, 73, 74

NR Band n79

FDL_low

FDL_high

-50

1

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

1805

1855

-40

1

33

Frequency range

1855

1880

-15.5

5

15,26,33

40

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 20, 21, 22, 26, 27, 28, 31, 32, 33, 34, 38, 39, 41, 42, 43, 44, 45, 50, 51, 52, 65, 67, 68, 69, 72, 73, 74, 75, 76, 87, 88

NR Band n77, n78, n100, n101

FDL_low

FDL_high

-50

1

NR Band n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

8

41

E-UTRA Band 1, 2, 3, 4, 5, 8, 12, 13 , 14, 17, 24, 25, 26, 27, 28, 29, 30, 34, 39, 40, 42, 44, 45, 48, 50, 51, 52, 54, 65, 66, 70, 71, 73, 74, 85, 103

NR Band n77, n78

FDL_low

FDL_high

-50

1

E-UTRA Band 9, 11, 18, 19, 21

FDL_low

FDL_high

-50

1

30

NR Band n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

8, 30

42

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 11, 18, 19, 20, 21, 25, 26, 27, 28, 31, 32, 33, 34, 38, 40, 41, 44, 45, 50, 51, 65, 66, 67, 68, 69, 72, 73, 74, 75, 76, 87, 88

NR Band n79, n100, n101

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

8

43

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 20, 25, 26, 27, 28, 31,32, 33, 34, 38, 40, 50, 51, 65, 66, 67, 68, 69, 72, 73, 74, 75, 76, 85, 87, 88

NR Band n100, n101

FDL_low

FDL_high

-50

1

44

E-UTRA Band 1, 40, 42, 45

FDL_low

FDL_high

-50

1

2

E-UTRA Band 3, 5, 8, 34, 39, 41, 73

FDL_low

FDL_high

-50

1

45

E-UTRA Band 1, 3, 5, 8, 34, 39, 40, 41, 42, 44, 52, 73

FDL_low

FDL_high

-50

1

47

E-UTRA Band 1, 3, 5, 7, 8, 22, 26, 28, 34, 39, 40, 41, 42, 44, 45, 65, 68, 72, 73

NR band n77, n78 , n79

FDL_low

FDL_high

-50

1

Frequency range

5925

5950

-30 EIRP

1

38, 40, 43

Frequency range

5815

5855

-30 EIRP

1

38, 43, 45

48

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 26, 29, 30, 41, 50, 51, 54, 66, 70, 71, 74, 85, 103

FDL_low

FDL_high

-50

1

50

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 12, 13, 17, 20, 26, 28, 29, 31, 34, 38, 39, 40, 41, 42, 43, 48, 52, 65, 66, 67, 68, 85, 103

NR Band n100, n101

FDL_low

FDL_high

-50

1

51

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 12, 13, 17, 20, 26, 28, 29, 31, 34, 38, 39, 40, 41, 42, 43, 48, 52, 65, 66, 67, 68, 85, 103

NR Band n100, n101

FDL_low

FDL_high

-50

1

52

E-UTRA Band 1, 3, 5, 7, 8, 20, 28, 31, 33, 34, 38, 39, 40, 41, 45, 47, 50, 51, 68, 72, 73, 74, 87, 88

NR Band n100, n101

FDL_low

FDL_high

-50

1

53

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 26, 29, 30, 48, 54, 66, 70, 71, 85, 103

NR Band n77

FDL_low

FDL_high

-50

1

54

E-UTRA Band 2, 4, 5, 8, 12, 13, 14, 17, 23, 24, 25, 26, 29, 30, 48, 50, 51, 53, 66, 70, 71, 85, 103

NR NTN Band n255, n256

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

2

65

E-UTRA Band 1, 3, 7, 8, 20, 22, 28, 31, 32, 38, 40, 42, 43, 50, 51, 65, 68, 69, 72, 74, 75, 76, 87, 88

NR Band n78, n79, n100, n101

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 5, 11, 18, 19, 21, 26, 27, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 34

FDL_low

FDL_high

-50

1

36

Frequency range

1884.5

1915.7

-41

0.3

37

Frequency range

1900

1915

-15.5

5

15, 26, 27

Frequency range

1915

1920

+1.6

5

15, 26, 27

66

E-UTRA Band 2, 4, 5, 7, 12, 13, 14, 17, 24, 25, 26, 27, 28, 29, 30, 38, 41, 43, 50, 51, 53, 66, 70, 71, 74, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 42, 48,

NR Band n77

FDL_low

FDL_high

-50

1

2

68

E-UTRA Band 3, 7, 8, 20, 28, 31, 38, 40, 47, 72, 74, 87, 88

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 22, 42, 43, 50, 51, 52, 65

FDL_low

FDL_high

-50

1

2

70

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 26, 29, 30, 41, 48, 53, 66, 70, 71, 85, 103

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

2

71

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 30, 48, 53, 54, 66, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25, 41, 70,

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 29

FDL_low

FDL_high

-38

1

15

E-UTRA Band 71

FDL_low

FDL_high

-50

1

15

72

E-UTRA Band 1, 7, 20, 22, 28, 31, 32, 33, 34, 38, 42, 43, 47, 52, 65, 68, 72, 87, 88

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 8, 40

FDL_low

FDL_high

-50

1

2

Frequency range

470

694

-42

8

73

E-UTRA Band 1, 26, 28, 33, 34, 39, 41, 42, 43, 44, 45, 47, 52

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 5, 8, 27, 40

FDL_low

FDL_high

-50

1

2

74

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 12, 13, 17, 18, 19, 20, 26, 28, 29, 31, 34, 38, 39, 40, 41, 42, 43, 48, 52, 65, 66, 67, 68, 85, 103

NR Band n77, n78, n100, n101

FDL_low

FDL_high

-50

1

NR Band n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

8

Frequency range

1400

1427

-32

27

15, 41

Frequency range

1475

1488

-50

1

42

Frequency range

1488

1518

-50

1

15

85

E-UTRA Band 2, 5, 13, 14, 17, 24, 25, 26, 27, 30, 41, 53, 54, 70, 71, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 48, 51, 66

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA Band 2, 5, 13, 14, 17, 24, 25, 26, 27, 30, 41, 53, 70, 71, 74, 103

FDL_low

FDL_high

-50

1

15

87

E-UTRA Band 1, 3, 7, 8, 22, 28, 31, 32, 33, 34, 38, 40, 42, 43, 47, 52, 65, 68, 72

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA Band, 20

FDL_low

FDL_high

-50

1

2

E-UTRA Band 87, 88

FDL_low

FDL_high

-50

1

15

Frequency range

470

694

-42

8

88

E-UTRA Band 1, 3, 7, 8, 20, 22, 28, 31, 32, 33, 34, 38, 40, 42, 43, 47, 52, 65, 68, 72

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA Band 87

FDL_low

FDL_high

-20

1

15

E-UTRA Band 88

FDL_low

FDL_high

-50

1

15

Frequency range

470

694

-42

8

103

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 25, 26, 27, 29, 41, 48, 50, 51, 53, 54, 66, 70, 71, 74, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 24, 30,

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

Frequency range

799

805

-35

0.00625

NOTE 1: FDL_low and FDL_high refer to each E-UTRA frequency band specified in Table 5.5-1

NOTE 2: As exceptions, measurements with a level up to the applicable requirements defined in Table 6.6.3.1-2 are permitted for each assigned E-UTRA carrier used in the measurement due to 2nd, 3rd, 4th [or 5th] harmonic spurious emissions. Due to spreading of the harmonic emission the exception is also allowed for the first 1 MHz frequency range immediately outside the harmonic emission on both sides of the harmonic emission. This results in an overall exception interval centred at the harmonic emission of (2MHz + N x LCRB x 180kHz), where N is 2, 3, 4, [5] for the 2nd, 3rd, 4th [or 5th] harmonic respectively. The exception is allowed if the measurement bandwidth (MBW) totally or partially overlaps the overall exception interval.

NOTE 3: N/A

NOTE 4: N/A

NOTE 5: For non synchronised TDD operation to meet these requirements some restriction will be needed for either the operating band or protected band

NOTE 6: N/A

NOTE 7: Applicable when co-existence with PHS system operating in 1884.5 -1919.6MHz.

NOTE 8: Applicable when co-existence with PHS system operating in 1884.5 -1915.7MHz.

NOTE 9: N/A

NOTE 10: N/A

NOTE 11: Whether the applicable frequency range should be 793-805MHz instead of 799-805MHz is TBD

NOTE 12: The emissions measurement shall be sufficiently power averaged to ensure a standard deviation < 0.5 dB

NOTE 13: N/A

NOTE 14: N/A

NOTE 15: These requirements also apply for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 and Table 6.6.3.1A-1 from the edge of the channel bandwidth.

NOTE 16: N/A

NOTE 17: N/A

NOTE 18: N/A

NOTE 19: Applicable when the assigned E-UTRA carrier is confined within 718 MHz and 748 MHz and when the channel bandwidth used is 5 or 10 MHz.

NOTE 20: N/A

NOTE 21: This requirement is applicable for any channel bandwidths within the range 2500 – 2570 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 2560.5 – 2562.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 2552 – 2560 MHz the requirement is applicable only for an uplink transmission bandwidth less than or equal to 54 RB.

NOTE 22: This requirement is applicable for power class 3 UE for any channel bandwidths within the range 2570 – 2615 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 2605.5 – 2607.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 2597 – 2605 MHz the requirement is applicable only for an uplink transmission bandwidth less than or equal to 54 RB. For power class 2 UE for any channel bandwidths within the range 2570 – 2615 MHz, NS_44 shall apply.
For power class 2 or 3 UE for carriers with channel bandwidth overlapping the frequency range 2615 – 2620 MHz the requirement applies with the maximum output power configured to +19 dBm in the IE P-Max.

NOTE 23: This requirement is applicable only for the following cases:
– for carriers of 5 MHz channel bandwidth when carrier centre frequency (Fc) is within the range 902.5 MHz ≤ Fc < 907.5 MHz with an uplink transmission bandwidth less than or equal to 20 RB
– for carriers of 5 MHz channel bandwidth when carrier centre frequency (Fc) is within the range 907.5 MHz ≤ Fc ≤ 912.5 MHz without any restriction on uplink transmission bandwidth.
– for carriers of 10 MHz channel bandwidth when carrier centre frequency (Fc) is Fc = 910 MHz with an uplink transmission bandwidth less than or equal to 32 RB with RBstart > 3.

NOTE 24: As exceptions, measurements with a level up to the applicable requirement of -38 dBm/MHz is permitted for each assigned E-UTRA carrier used in the measurement due to 2nd harmonic spurious emissions. An exception is allowed if there is at least one individual RB within the transmission bandwidth (see Figure 5.6-1) for which the 2nd harmonic totally or partially overlaps the measurement bandwidth (MBW).

NOTE 25: As exceptions, measurements with a level up to the applicable requirement of -36 dBm/MHz is permitted for each assigned E-UTRA carrier used in the measurement due to 3rd harmonic spurious emissions. An exception is allowed if there is at least one individual RB within the transmission bandwidth (see Figure 5.6-1) for which the 3rd harmonic totally or partially overlaps the measurement bandwidth (MBW).

NOTE 26: For these adjacent bands, the emission limit could imply risk of harmful interference to UE(s) operating in the protected operating band.

NOTE 27: This requirement is applicable for any channel bandwidths within the range 1920 – 1980 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 1927.5 – 1929.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 1930 – 1938 MHz the requirement is applicable only for an uplink transmission bandwidth less than or equal to 54 RB.

NOTE 28: N/A

NOTE 29: N/A

NOTE 30: This requirement applies when the E-UTRA carrier is confined within 2545-2575MHz or 2595-2645MHz and the channel bandwidth is 10 or 20 MHz

NOTE 31: N/A

NOTE 32: Void

NOTE 33: This requirement is only applicable for carriers with bandwidth confined within 1885-1920 MHz (requirement for carriers with at least 1RB confined within 1880 – 1885 MHz is not specified). This requirement applies for an uplink transmission bandwidth less than or equal to 54 RB for carriers of 15 MHz bandwidth when carrier center frequency is within the range 1892.5 – 1894.5 MHz and for carriers of 20 MHz bandwidth when carrier center frequency is within the range 1895 – 1903 MHz.

NOTE 34: This requirement is applicable for 5 and 10 MHz E-UTRA channel bandwidth allocated within 718-728MHz. For carriers of 10 MHz bandwidth, this requirement applies for an uplink transmission bandwidth less than or equal to 30 RB with RBstart > 1 and RBstart<48.

NOTE 35: This requirement is applicable in the case of a 10 MHz E-UTRA carrier confined within 703 MHz and 733 MHz, otherwise the requirement of -25 dBm with a measurement bandwidth of 8 MHz applies.

NOTE 36: This requirement is applicable for E-UTRA channel bandwidth allocated within 1920-1980 MHz.

NOTE 37: Applicable when the upper edge of the channel bandwidth frequency is greater than 1980MHz.

NOTE 38: Applicable when NS_33 or NS_34 is configured by the pre-configured radio parameters.

NOTE 39: Applicable only when the assigned E-UTRA carrier is confined within 824 MHz and 849 MHz for UE category M1, M2 and UE category NB1 and NB2.

NOTE 40: In the frequency range x-5950MHz, SE requirement of -30dBm/MHz should be applied; where x = max (5925, fc + 15), where fc is the channel centre frequency.

NOTE 41: Applicable for all bandwidths, and when the lower edge of the assigned E-UTRA UL channel bandwidth frequency is greater than or equal to 1427 MHz + the channel BW assigned for 1.4, 3, 5 and 10 MHz bandwidth, and when the lower edge of the assigned E-UTRA UL channel bandwidth frequency is greater than or equal to 1440 MHz for 15 and 20 MHz bandwidth. This requirement shall be verified with UE transmission power of 15 dBm.

NOTE 42: Applicable for 1.4 , 3 and 5 MHz bandwidth, and when the upper edge of the assigned E-UTRA UL channel bandwidth frequency is less than or equal to 1467 MHz assigned for10 MHz bandwidth, and when the upper edge of the assigned E-UTRA UL channel bandwidth frequency is less than or equal to 1463.8 MHz for 15 MHz bandwidth, and when the upper edge of the assigned E-UTRA UL channel bandwidth frequency is less than or equal to 1460.8 MHz for 20 MHz bandwidth.

NOTE 43: The EIRP requirement is converted to conducted requirement depend on the supported post antenna connector gain Gpost connector declared by the UE following the principle described in annex I.

NOTE 44: For category NB1 and NB2 UE when carrier centre frequency is 1920.1 MHz, in case of single-tone uplink transmission the requirement is applicable only for sub-carrier index > 2.

NOTE 45: Resolution BW is 10% of the measurement BW and the result should be integrated to achieve the measurement bandwidth. The sweep time shall be set at least as (sweep points)*(symbol length) to improve the measurement accuracy.

NOTE: The restriction on the maximum uplink transmission to 54 RB in Notes 21, 22, and 27 of Table 6.6.3.2-1 and the restriction on the single-tone uplink transmission to sub-carrier index > 2 in Note 44 of Table 6.6.3.2-1 are intended for conformance testing and may be applied to network operation to facilitate coexistence when the aggressor and victim bands are deployed in the same geographical area. The applicable spurious emission requirement of -15.5 dBm/5MHz is a least restrictive technical condition for FDD/TDD coexistence and may have to be revised in the future.

When "NS_33" or “NS 34” is configured from pre-configured radio parameters or the cell and the indication from upper layers has indicated that the UE is within the protection zone of CEN DSRC devices or HDR DSRC devices, the power of any V2X UE emission shall fulfil either one of the two set of conditions.

Maximum Transmission Power (dBm EIRP)

Emission Limit in Frequency Range 5795-5815 (dBm/MHz EIRP)

Condition 1

10

-65

Condition 2

10

-45

6.6.3.2A Spurious emission band UE co-existence for CA

This clause specifies the requirements for the specified carr`ier aggregation configurations for coexistence with protected bands.

NOTE: For measurement conditions at the edge of each frequency range, the lowest frequency of the measurement position in each frequency range should be set at the lowest boundary of the frequency range plus MBW/2. The highest frequency of the measurement position in each frequency range should be set at the highest boundary of the frequency range minus MBW/2. MBW denotes the measurement bandwidth defined for the protected band.

For inter-band carrier aggregation with the uplink assigned to two E-UTRA bands, the requirements in Table 6.6.3.2A-0 apply on each component carrier with all component carriers are active.

NOTE: For inter-band carrier aggregation with uplink assigned to two E-UTRA bands the requirements in Table 6.6.3.2A-0 could be verified by measuring spurious emissions at the specific frequencies where second and third order intermodulation products generated by the two transmitted carriers can occur; in that case, the requirements for remaining applicable frequencies in Table 6.6.3.2A-0 would be considered to be verified by the measurements verifying the one uplink inter-band CA UE to UE co-existence requirements.

Table 6.6.3.2A-0: Requirements for uplink inter-band carrier aggregation (two bands)

E-UTRA CA Configuration

Spurious emission

Protected band

Frequency range (MHz)

Maximum Level (dBm)

MBW (MHz)

NOTE

CA_1-3

E-UTRA Band 1, 5, 7, 8, 11, 18, 19, 20, 21, 26, 27, 28, 31, 32, 38, 40, 41, 43, 44, 50, 51, 65, 67, 72, 73, 74, 75, 76

NR Band n79, n100, n101

FDL_low

FDL_high

-50

1

E-UTRA band 3, 34

FDL_low

FDL_high

-50

1

3

E-UTRA band 22, 42, 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

1880

1895

-40

1

3,12

Frequency range

1895

1915

-15.5

5

3, 12, 13

Frequency range

1915

1920

+1.6

5

3, 12, 13

CA_1-5

E-UTRA Band 1, 5, 7, 8, 22, 28, 31, 38, 40, 42, 43, 50, 51, 65, 73, 74

FDL_low

FDL_high

-50

1

E-UTRA band 3,34

FDL_low

FDL_high

-50

1

3

E-UTRA band 26

859

869

-27

1

E-UTRA band 41, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

CA_1-7

E-UTRA Band 1, 5, 7, 8, 20, 22, 26, 27, 28, 31,32, 40, 42, 43, 50, 51, 52, 65, 67, 72, 74, 75, 76

NR Band n78, n100, n101

FDL_low

FDL_high

-50

1

E-UTRA band 3, 34

FDL_low

FDL_high

-50

1

3

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

1880

1895

-40

1

3,12

Frequency range

1895

1915

-15.5

5

3, 12, 13

Frequency range

1915

1920

+1.6

5

3, 12, 13

Frequency range

2570

2575

+1.6

5

3, 13, 14

Frequency range

2575

2595

-15.5

5

3, 13, 14

Frequency range

2595

2620

-40

1

3, 14

CA_1-8

E-UTRA Band 1, 20, 28, 31, 32, 38, 40, 50, 51, 65, 67, 72, 73, 74, 75, 76

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA band 3, 7, 22, 41, 42, 43, 52

NR Band n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8, 34

FDL_low

FDL_high

-50

1

3

E-UTRA band 11, 21

FDL_low

FDL_high

-50

1

11

Frequency range

860

890

-40

1

3, 11

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

1880

1895

-40

1

3,12

Frequency range

1895

1915

-15.5

5

3, 12, 13

Frequency range

1915

1920

+1.6

5

3, 12, 13

CA_1-11

E-UTRA Band 1, 3, 11, 18, 19, 21, 28, 34, 40, 42, 65

NR Band n78, n79

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

945

960

-50

1

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

CA_1-18

E-UTRA Band 1, 3, 11, 21, 40, 42, 65

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 34

FDL_low

FDL_high

-50

1

3

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

758

799

-50

1

Frequency range

799

803

-40

1

3

Frequency range

860

890

-40

1

Frequency range

945

960

-50

1

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

CA_1-19

E-UTRA Band 1, 3, 11, 21, 28, 40, 42, 65

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 34

FDL_low

FDL_high

-50

1

3

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

945

960

-50

1

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

CA_1-20

E-UTRA Band 1, 3, 7, 8, 22, 31, 32, 34, 40, 43, 50, 51, 65, 67, 68, 72, 75, 76

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA Band 20

FDL_low

FDL_high

-50

1

3

E-UTRA Band 38, 42, 69

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

758

788

-50

1

CA_1-21

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 42, 65

NR Band n78, n79

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

CA_1-26

E-UTRA Band 1, 5, 7, 11, 18, 19, 21, 22, 26, 31, 38, 40, 42, 43, 50, 51, 65, 73, 74

NR Band n79

FDL_low

FDL_high

-50

1

Frequency range

1880

1895

-40

1

3, 12

Frequency range

1895

1915

-15.5

5

3, 12, 13

Frequency range

1915

1920

+1.6

5

3, 12, 13

Frequency range

945

960

-50

1

E-UTRA Band 41

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA Band 3, 34

FDL_low

FDL_high

-50

1

3

Frequency range

703

799

-50

1

799

803

-40

1

3

CA_1-28

E-UTRA Band 3, 5, 7, 8, 18, 19, 20, 26, 27, 31, 38, 40, 41, 72, 73

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA Band 22, 32, 42, 43, 50, 51, 52, 74, 75, 76

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 34

FDL_low

FDL_high

-50

1

3

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

5, 21

E-UTRA Band 1, 65

FDL_low

FDL_high

-50

1

5, 6

Frequency range

470

694

-42

8

3, 22

Frequency range

470

710

-26.2

6

23

Frequency range

758

773

-32

1

3

Frequency range

773

803

-50

1

Frequency range

662

694

-26.2

6

3

Frequency range

1880

1895

-40

1

3,12

Frequency range

1895

1915

-15.5

5

3, 12, 13

Frequency range

1915

1920

+1.6

5

3, 12, 13

CA_1-40

E-UTRA Band 1, 5, 7, 8, 11, 18, 19, 20, 21, 22, 26, 27, 28, 31, 32, 38, 41, 42, 43, 44, 45, 50, 51, 52, 65, 67, 68, 69, 72, 73, 74, 75, 76

NR band n78, n100, n101

FDL_low

FDL_high

-50

1

Band 3, 34

FDL_low

FDL_high

-50

1

3

NR band n77, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1880

1895

-40

1

3, 12

Frequency range

1895

1915

-15.5

5

3, 12, 13

Frequency range

1915

1920

+1.6

5

3, 12, 13

Frequency range

1884.5

1915.7

-41

0.3

4

CA_1-41

E-UTRA Band 1, 3, 5, 8, 26, 27, 28, 40, 42, 44, 45, 50, 51, 52, 65, 73, 74

NR Band n78

FDL_low

FDL_high

-50

1

E-UTRA Band 34

FDL_low

FDL_high

-50

1

3

NR Band n77, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1880

1895

-40

1

3,12

Frequency range

1895

1915

-15.5

5

3, 12, 13

Frequency range

1915

1920

+1.6

5

3, 12, 13

E-UTRA Band 11, 18, 19, 21

FDL_low

FDL_high

-50

1

30

CA_1-42

E-UTRA Band 1, 5, 7, 8, 11, 18, 19, 20, 21, 26, 27, 28, 31, 32, 38, 40, 41, 44, 50, 51, 65, 67, 72, 73, 74, 75, 76

NR Band n79, n100, n101

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 34

FDL_low

FDL_high

-50

1

3

Frequency range

1880

1895

-40

1

3,12

Frequency range

1895

1915

-15.5

5

3, 12, 13

Frequency range

1915

1920

+1.6

5

3, 12, 13

CA_2-4

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 27, 28, 29, 30, 41, 50, 51, 53, 66, 70, 71, 74, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

3

E-UTRA Band 22, 42, 43,

NR Band n77

FDL_low

FDL_high

-50

1

2

CA_2-5

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 28, 29, 30, 42, 50, 51, 54, 66, 70, 71, 74, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

3

E-UTRA Band 26

859

869

-27

1

E-UTRA Band 41, 43, 53

NR Band n77

FDL_low

FDL_high

-50

1

2

CA_2-7

E-UTRA Band 2, 4, 5, 7, 12, 13, 14, 17, 26, 27, 29, 30, 42, 50, 51, 65, 66, 70, 74, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 43

FDL_low

FDL_high

-50

1

2

CA_2-12

E-UTRA Band 5, 13, 14, 17, 24, 26, 27, 30, 41, 53, 54, 71, 74, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 12, 25, 85

FDL_low

FDL_high

-50

1

3

E-UTRA Band 4, 50, 51, 66, 70,

NR Band n77

FDL_low

FDL_high

-50

1

2

CA_2-13

E-UTRA Band 4, 5,12,13,17, 22, 26, 27, 29, 41, 42, 50, 51, 53, 54, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 2,14, 25, 103

FDL_low

FDL_high

-50

1

3

E-UTRA Band 24, 30, 43,

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

3

Frequency range

799

805

-35

0.00625

3

CA_2-14

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 27, 29, 30, 41, 53, 54, 66, 70, 71, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

3

E-UTRA Band 48

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

3

Frequency range

799

805

-35

0.00625

3, 9

CA_2-48

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 25, 26, 29, 30, 41, 50, 51, 53, 54, 66, 70, 71, 74, 85, 103

FDL_low

FDL_high

-50

1

CA_2-49

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 25, 26, 29, 30, 41, 50, 51, 53, 66, 70, 71, 74, 85, 103

FDL_low

FDL_high

-50

1

CA_3-5

E-UTRA Band 1, 5, 7, 8, 28, 31, 38, 40, 43, 50, 51, 65, 73, 74

FDL_low

FDL_high

-50

1

E-UTRA band 3,34

FDL_low

FDL_high

-50

1

3

E-UTRA Band 22, 42, 52

FDL_low

FDL_high

-50

1

2

E-UTRA band 26

859

869

-27

1

CA_3-7

E-UTRA Band 1, 5, 7, 8, 20, 26, 27, 28, 31, 32, 33, 34, 40, 43, 44, 50, 51, 65, 67, 72, 74, 75, 76

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA band 3

FDL_low

FDL_high

-50

1

3

E-UTRA band 22, 42, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

2570

2575

+1.6

5

3, 13, 14

Frequency range

2575

2595

-15.5

5

3, 13, 14

Frequency range

2595

2620

-40

1

3, 14

CA_3-8

E-UTRA Band 1, 20, 28, 31, 32, 33, 34, 38, 39, 40, 44, 50, 51, 65, 67, 72, 73, 74, 75, 76

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA band 3, 8

FDL_low

FDL_high

-50

1

2, 3

E-UTRA band 11, 21

FDL_low

FDL_high

-50

1

10,11

E-UTRA band 7, 22, 41, 42, 43, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

4, 10, 11

Frequency range

860

890

-40

1

3,11,17

CA_3A-11A

E-UTRA Band 1, 18, 19, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

E-UTRA band 3

FDL_low

FDL_high

-50

1

3

E-UTRA Band 42

FDL_low

FDL_high

-50

1

2

Frequency range

945

960

-50

1

 

Frequency range

1884.5

1915.7

-41

0.3

4

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

CA_3-18

E-UTRA Band 1, 3, 11, 21, 28, 34, 40, 65

NR Band n79

FDL_low

FDL_high

-50

1

NR Band n77, n78,

FDL_low

FDL_high

-50

1

2

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

4

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

CA_3-19

E-UTRA Band 1, 11, 21, 28, 40, 65

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 34

FDL_low

FDL_high

-50

1

3

E-UTRA Band 42

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3, 4

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

CA_3-20

E-UTRA Band 1, 7, 8, 31, 32, 33, 34, 40, 43, 50, 51, 65, 67, 72, 74, 75, 76

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 20

FDL_low

FDL_high

-50

1

3

E-UTRA Band 22, 38, 42, 52

FDL_low

FDL_high

-50

1

2

Frequency range

758

788

-50

1

CA_3-21

E-UTRA Band 1, 18, 19, 28, 34, 40, 65

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA band 3

FDL_low

FDL_high

-50

1

3

E-UTRA Band 42

NR Band n77, n78,

FDL_low

FDL_high

-50

1

2

Frequency range

945

960

-50

1

 

Frequency range

1884.5

1915.7

-41

0.3

4

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

CA_3-26

E-UTRA Band 1, 5, 7, 11, 18, 19, 21, 26, 34, 39, 40, 43, 50, 51, 65, 73, 74

FDL_low

FDL_high

-50

1

E-UTRA band 3

FDL_low

FDL_high

-50

1

3

E-UTRA band 22, 41, 42

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

4

Frequency range

703

799

-50

1

799

803

-40

1

3

Frequency range

945

960

-50

1

CA_3-28

E-UTRA Band 1, 11, 18, 19, 21, 22, 32, 42, 43, 50, 51, 52, 65, 74, 75, 76

NR Band n77, n78, n79, n100, n101

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

5, 6

E-UTRA band 3

FDL_low

FDL_high

-50

1

3

E-UTRA Band 5, 7, 8, 20, 26, 27, 31, 34, 38, 40, 41, 72, 73

FDL_low

FDL_high

-50

1

Frequency range

470

710

-26.2

6

23

Frequency range

758

773

-32

1

3

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

4, 5

CA_3-38

E-UTRA Band 1, 5, 8, 20, 27, 28, 31, 32, 33, 34, 40, 43, 50, 51, 65, 67, 68, 72, 74, 75, 76

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA Band 22, 42

FDL_low

FDL_high

-50

1

2

CA_3-40

E-UTRA Band 1, 5, 7, 8, 11, 18, 19, 20, 21, 26, 27, 28, 31, 32, 33, 34, 38, 39, 41, 43, 44. 45, 50, 51, 65, 67, 68, 69, 72, 73, 74, 75, 76

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA Band 3

FDL_low

FDL_high

-50

1

3

E-UTRA Band 22, 42, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

CA_3-41

E-UTRA Band 1, 5, 8, 26, 28, 33, 34, 39, 40, 44, 45, 50, 51, 65, 73, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 3

FDL_low

FDL_high

-50

1

3

E-UTRA Band 11, 18, 19, 21

FDL_low

FDL_high

-50

1

18

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

4, 18

CA_3-42

E-UTRA Band 1, 5, 7, 8, 20, 26, 27, 28, 31, 32, 33, 34, 38, 40, 41, 44, 45, 50, 51, 65, 67, 72, 73, 74, 75, 76

NR Band n79, n100, n101

FDL_low

FDL_high

-50

1

E-UTRA Band 3

FDL_low

FDL_high

-50

1

3

E-UTRA Band 11, 18, 19, 21

FDL_low

FDL_high

-50

1

13

Frequency range

1884.5

1915.7

-41

0.3

4

CA_4-5

E-UTRA Band 2, 4, 5, 7, 12, 13, 14, 17, 24, 25, 28, 29, 30, 43, 50, 51, 66, 70, 71, 74, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 26

859

869

-27

1

E-UTRA band 41, 42, 53

NR Band n77

FDL_low

FDL_high

-50

1

2

CA_4-7

E-UTRA Band 2, 4, 5, 7, 12, 13, 14, 17, 26, 27, 28, 29, 30, 43, 50, 51, 66, 74, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA band 42

FDL_low

FDL_high

-50

1

2

Frequency range

2570

2575

+1.6

5

3, 13, 14

Frequency range

2575

2595

-15.5

5

3, 13, 14

Frequency range

2595

2620

-40

1

3, 14

CA_4-12

E-UTRA Band 2, 5, 7,13, 14, 17, 24, 25, 26, 27, 30, 41, 43, 53, 71, 74, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 22, 42, 50, 51, 66, 70,

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 12, 85

FDL_low

FDL_high

-50

1

3

CA_4-13

E-UTRA Band 2,4, 5, 7, 12,13,17,25, 26, 27, 29, 41, 43, 50, 51, 53, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 14, 103

FDL_low

FDL_high

-50

1

3

E-UTRA Band 22, 24, 30, 42,

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

3

Frequency range

799

805

-35

0.00625

3

CA_4-17

E-UTRA Band 2, 5, 7,13, 14, 17, 24, 25, 26, 27, 30, 41, 43, 53, 71, 74, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 22, 42, 50, 51, 66, 70,

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 12, 85

FDL_low

FDL_high

-50

1

3

CA_4-28

E-UTRA Band 2, 5, 7, 14, 24, 25, 26, 27, 30, 41, 53, 70, 71

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 42, 43, 48 50, 51, 66, 74

FDL_low

FDL_high

-50

1

2

Frequency range

470

710

-26.2

6

23

Frequency range

758

773

-32

1

3

Frequency range

773

803

-50

1

CA_5-7

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 12, 13, 14, 17, 22, 28, 29, 30, 31, 40, 42, 43, 50, 51, 65, 66, 74, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA band 26

859

869

-27

1

Frequency range

2570

2575

+1.6

5

3, 13, 14

Frequency range

2575

2595

-15.5

5

3, 13, 14

Frequency range

2595

2620

-40

1

3, 14

CA_5-12

E-UTRA Band 2, 5, 13, 14, 17, 24, 25, 30, 31, 43, 54, 71, 74, 103

FDL_low

FDL_high

-50

1

E-UTRA band 4, 22, 41, 42, 50, 51, 53, 66, 70,

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA band 26

859

869

-27

1

E-UTRA band 12, 85

FDL_low

FDL_high

-50

1

3

CA_5-17

E-UTRA Band 2, 5, 13, 14, 17, 24, 25, 30, 31, 43, 54, 71, 74, 103

FDL_low

FDL_high

-50

1

E-UTRA band 4, 22, 41, 42, 50, 51, 53, 66, 70,

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA band 26

859

869

-27

1

E-UTRA band 12, 85

FDL_low

FDL_high

-50

1

3

CA_5-40

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 21, 28, 31, 34, 38, 42, 43, 45, 65, 73, 74

FDL_low

FDL_high

-50

1

E-UTRA band 26

859

869

-27

1

E-UTRA band 41, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

4

CA_7-8

E-UTRA Band 1, 20, 27, 28, 31, 32, 34, 40, 50, 51, 65, 67, 68, 72, 74, 75, 76

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA band 3, 7, 22, 42, 43, 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

3

Frequency range

2570

2575

+1.6

5

3, 13, 14

Frequency range

2575

2595

-15.5

5

3, 13, 14

Frequency range

2595

2620

-40

1

3, 14

CA_7-20

E-UTRA Band 1,3, 7, 8, 22, 28, 31, 32, 33, 34, 40, 43, 50, 51, 65, 67, 72, 74, 75, 76

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA Band 20

FDL_low

FDL_high

-50

1

3

E-UTRA Band 42, 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

2570

2575

+1.6

5

2, 3, 13, 14

Frequency range

2575

2595

-15.5

5

2, 3, 13, 14

Frequency range

2595

2620

-40

1

3, 14

CA_7-26

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 12, 13, 14, 17, 22, 29, 30, 31, 40, 42, 43, 65, 66, 85, 103

FDL_low

FDL_high

-50

1

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

2570

2575

+1.6

5

3, 13, 14

Frequency range

2575

2595

-15.5

5

3, 13, 14

Frequency range

2595

2620

-40

1

3, 14

Frequency range

703

799

-50

1

Frequency range

799

803

-40

1

3

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

7

CA_7-28

E-UTRA Band 2, 3, 5, 7, 8, 20, 26, 27, 31, 34, 40, 72

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 4, 22, 32, 42, 43, 50, 51, 52, 65, 66, 74, 75, 76

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

5, 6

Frequency range

758

773

-32

1

3

Frequency range

773

803

-50

1

Frequency range

2570

2575

+1.6

5

3, 13, 14

Frequency range

2575

2595

-15.5

5

3, 13, 14

Frequency range

2595

2620

-40

1

3, 14

CA_8-20

E-UTRA Band 1, 28, 31, 32, 33, 34, 39, 40, 45, 50, 51, 65, 67, 68, 72, 73, 74, 75, 76, 87, 88

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA band 3, 7, 22, 38, 41, 42, 43, 52, 69

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8, 20

FDL_low

FDL_high

-50

1

3

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

11

Frequency range

758

788

-50

1

Frequency range

860

890

-40

1

3, 11

CA_8-28

E-UTRA Band 3, 4, 7, 22, 32, 41, 42, 43, 50, 51, 52, 65, 66, 73, 74, 75, 76

NR Band n77, n78, n79, n100, n101

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

2, 5, 21

E-UTRA Band 8

FDL_low

FDL_high

-50

1

3

E-UTRA Band 2, 18, 20, 25, 27, 28, 31, 33, 34, 38, 39, 40, 68, 69, 72, 87, 88

FDL_low

FDL_high

-50

1

E-UTRA Band 11, 21, 45

FDL_low

FDL_high

-50

1

21

Frequency range

470

694

-42

8

3, 22

Frequency range

470

710

-26.2

6

23

Frequency range

662

694

-26.2

6

3

Frequency range

758

773

-32

1

3

Frequency range

773

803

-50

1

Frequency range

860

890

-40

1

3, 11

Frequency range

1884.5

1915.7

-41

0.3

4, 5, 11

CA_8-39

E-UTRA Band 1, 28, 40, 45, 50, 51, 73, 74

FDL_low

FDL_high

-50

1

E-UTRA band 22, 41, 42, 52

NR band n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

3

CA_8-41

E-UTRA Band 1, 28, 34, 39, 40, 45, 50, 51, 65, 73, 74

FDL_low

FDL_high

-50

1

 

E-UTRA band 3, 42, 52, 54

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA band 11, 21

FDL_low

FDL_high

-50

1

11

Frequency range

1884.5

1915.7

-41

0.3

4, 11

CA_11-18

E-UTRA Band 1, 3, 11, 21, 28, 34, 40, 42, 65

NR Band n79

FDL_low

FDL_high

-50

1

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

860

890

-40

1

3

Frequency range

1884.5

1915.7

-41

0.3

4

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

Frequency range

945

960

-50

1

CA_11-26

E-UTRA Band 1, 3, 11, 18, 19, 21, 26, 28, 34, 40, 42, 65

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

4

Frequency range

2545

2575

-50

1

2

Frequency range

2595

2645

-50

1

Frequency range

945

960

-50

1

CA_13-48

E-UTRA Band 2, 4, 5, 12, 13, 17, 25, 26, 29, 41, 50, 51, 66, 70, 71, 74, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA band 24, 30

FDL_low

FDL_high

-50

1

2

E-UTRA band 14

FDL_low

FDL_high

-50

1

3

CA_13-66

E-UTRA Band 2, 4, 5, 12, 13, 17, 25, 26, 27, 29, 41, 50, 51, 53, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 14, 103

FDL_low

FDL_high

-50

1

3

E-UTRA Band 24, 30, 48,

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

3

Frequency range

799

805

-35

0.00625

3, 9

CA_14-30

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 26, 27, 29, 30, 41, 48, 53, 54, 66, 70, 71, 85, 103

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

3

Frequency range

799

805

-35

0.00625

3, 9

CA_14-66

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 26, 27, 29, 30, 41, 53, 66, 70, 71, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 48,

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

3

Frequency range

799

805

-35

0.00625

3, 9

CA_18-28

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

5, 21

E-UTRA Band 1, 65

FDL_low

FDL_high

-50

1

5, 6

E-UTRA Band 42, 43

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 3, 34, 40

FDL_low

FDL_high

-50

1

Frequency range

470

710

-26.2

6

23

Frequency range

758

773

-32

1

3

Frequency range

773

799

-50

1

Frequency range

799

803

-40

1

3

Frequency range

860

890

-40

1

Frequency range

945

960

-50

1

3

Frequency range

1884.5

1915.7

-41

0.3

4

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

CA_19-21

E-UTRA Band 1, 3, 28, 34, 40, 42, 65

NR Band n79

FDL_low

FDL_high

-50

1

NR Band n77, n78,

FDL_low

FDL_high

-50

1

2

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

4

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

CA_19-42

E-UTRA Band 1, 3, 11, 21, 28, 34, 40, 65

NR Band n79

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

4

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

CA_21-28

E-UTRA Band 1, 42, 65

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

5, 6

E-UTRA Band 3, 18, 19, 34, 40

NR Band n79

FDL_low

FDL_high

-50

1

Frequency range

470

710

-26.2

6

23

Frequency range

773

803

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

4, 5

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

CA_21-42

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 65

NR Band n79

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

4

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

CA_25-26

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 29, 30, 42, 54, 66, 70, 71, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 48, 53

NR Band n77

FDL_low

FDL_high

-50

1

2

CA_25-41

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 27, 28, 29, 30, 42, 45, 54, 66, 70, 71, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25, 48

NR Band n77

FDL_low

FDL_high

-50

1

2

CA_26-46

E-UTRA Band 1, 2, 3, 4, 5, 11, 12, 13, 14, 17, 18,19, 21, 24, 25, 26, 29, 30, 31, 34, 39, 40, 42, 43, 48, 54, 65, 66, 70, 71, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 41, 53,

NR Band n77

FDL_low

FDL_high

-50

1

1, 2

Frequency range

703

799

-50

1

Frequency range

799

803

-40

1

2

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

CA_26-48

E-UTRA Band 1, 2, 3, 4, 5, 11, 12, 13, 14, 17, 18,19, 21, 24, 25, 26, 29, 30, 31, 34, 39, 40, 50, 51, 54, 65, 66, 70, 71, 73, 74, 103

FDL_low

FDL_high

-50

1

1, 2

E-UTRA Band 41

FDL_low

FDL_high

-50

1

1, 2

Frequency range

703

799

-50

1

Frequency range

799

803

-40

1

2

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

CA_28-40

E-UTRA Band 3, 5, 7, 8, 18, 19, 20, 26, 27, 31, 34, 38, 41, 72

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA band 1, 11, 21, 22, 32, 42, 43, 50, 51, 52, 65, 73, 74, 75, 76

NR Band, n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

758

773

-32

1

15

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

4

CA_28-41

E-UTRA Band E-UTRA Band 1, 4, 22, 32, 42, 45, 43, 48, 52, 65, 66

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

5, 6

E-UTRA band 2, 3, 5, 8, 20, 25, 26, 27, 31, 33, 34, 40

FDL_low

FDL_high

-50

1

E-UTRA band 11, 21

FDL_low

FDL_high

-50

1

5, 18, 21

E-UTRA band 9, 18, 19

FDL_low

FDL_high

-50

1

5, 18

Frequency range

470

694

-42

8

3, 22

Frequency range

470

710

-26.2

6

23

Frequency range

662

694

-26.2

6

3

Frequency range

758

773

-32

1

3

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

4, 5, 18

CA_28-42

E-UTRA Band 1, 4, 32, 50, 51, 66, 65, 74, 75, 76

NR Band n100, n101

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

5, 6

E-UTRA Band 2, 3, 5, 7, 8, 18, 19, 20, 25, 26, 27, 31, 34, 38, 40, 41, 72, 73

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

5, 21

Frequency range

470

710

-26.2

6

23

Frequency range

758

773

-32

1

3

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

4, 5

CA_30-48

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 26, 29, 30, 41, 54, 66, 70, 71, 85, 103

FDL_low

FDL_high

-50

1

CA_39-41

E-UTRA Band 1, 8, 26, 28, 34, 40, 42, 44, 50, 51, 52, 73, 74

FDL_low

FDL_high

-50

1

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1805

1855

-40

1

20

Frequency range

1855

1880

-15.5

5

3, 13, 20

CA_40-42

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 11, 12, 13, 14, 17, 18, 19, 20, 21, 24, 25, 26, 27, 28, 29, 31, 32, 33, 34, 38, 39, 41, 44, 45, 50, 51, 65, 66, 67, 68, 69, 70, 72, 73, 74, 75, 76, 103

NR Band n100, n101

FDL_low

FDL_high

-50

1

NR Band n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

8

CA_41-42

E-UTRA Band 1, 3, 5, 8, 26, 28, 33, 34, 39, 40, 44, 45, 50, 51, 65, 73, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 9, 11, 18, 19, 21

FDL_low

FDL_high

-50

1

18

NR Band n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

4, 18

CA_48-66

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 26, 29, 30, 41, 50, 51, 66, 70, 71, 74, 85, 103

FDL_low

FDL_high

-50

1

NOTE 1: FDL_low and FDL_high refer to each E-UTRA frequency band specified in Table 5.5-1

NOTE 2: As exceptions, measurements with a level up to the applicable requirements defined in Table 6.6.3.1-2 are permitted for each assigned E-UTRA carrier used in the measurement due to 2nd, 3rd, 4th [or 5th] harmonic spurious emissions. In case the exceptions are allowed due to spreading of the harmonic emission the exception is also allowed for the first 1 MHz frequency range immediately outside the harmonic emission on both sides of the harmonic emission. This results in an overall exception interval centred at the harmonic emission of (2MHz + N x LCRB x 180kHz), where N is 2, 3 or 4 for the 2nd, 3rd or 4th harmonic respectively. The exception is allowed if the measurement bandwidth (MBW) totally or partially overlaps the overall exception interval.

NOTE 3: These requirements also apply for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 and Table 6.6.3.1A-1 from the edge of the aggregated channel bandwidth.

NOTE 4: Applicable when co-existence with PHS system operating in 1884.5 -1915.7MHz.

NOTE 5: Applicable when the assigned E-UTRA carrier is confined within 718 MHz and 748 MHz and when the channel bandwidth used is 5 or 10 MHz.

NOTE 6: As exceptions, measurements with a level up to the applicable requirement of -36 dBm/MHz is permitted for each assigned E-UTRA carrier used in the measurement due to 3rd harmonic spurious emissions. An exception is allowed if there is at least one individual RB within the transmission bandwidth (see Figure 5.6-1) for which the 3rd harmonic totally or partially overlaps the measurement bandwidth (MBW).

NOTE 7: Void

NOTE 8: Void

NOTE 9: Void

NOTE10: Void

NOTE 11: This requirement is applicable only for the following cases:
– for carriers of 5 MHz channel bandwidth when carrier centre frequency (Fc) is within the range 902.5 MHz ≤ Fc < 907.5 MHz with an uplink transmission bandwidth less than or equal to 20 RB
– for carriers of 5 MHz channel bandwidth when carrier centre frequency (Fc) is within the range 907.5 MHz ≤ Fc ≤ 912.5 MHz without any restriction on uplink transmission bandwidth.
– for carriers of 10 MHz channel bandwidth when carrier centre frequency (Fc) is Fc = 910 MHz with an uplink transmission bandwidth less than or equal to 32 RB with RBstart > 3.

NOTE 12: This requirement is applicable for any channel bandwidths within the range 1920 – 1980 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 1927.5 – 1929.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 1930 – 1938 MHz the requirement is applicable only for an uplink transmission bandwidth less than or equal to 54 RB.

NOTE13: For these adjacent bands, the emission limit could imply risk of harmful interference to UE(s) operating in the protected operating band.

NOTE 14: This requirement is applicable for any channel bandwidths within the range 2500 – 2570 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 2560.5 – 2562.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 2552 – 2560 MHz the requirement is applicable only for an uplink transmission bandwidth less than or equal to 54 RB.

NOTE 15: Void

NOTE 16: Void

NOTE 17: This requirement is applicable only when Band 3 transmission frequency is less than or equal to 1765 MHz.

NOTE 18: This requirement applies when the E-UTRA carrier is confined within 2545-2575MHz or 2595-2645MHz and the channel bandwidth is 10 or 20 MHz

NOTE 19: Void

NOTE 20: This requirement is only applicable for carriers with bandwidth confined within 1885-1920 MHz (requirement for carriers with at least 1RB confined within 1880 – 1885 MHz is not specified). This requirement applies for an uplink transmission bandwidth less than or equal to 54 RB for carriers of 15 MHz bandwidth when carrier center frequency is within the range 1892.5 – 1894.5 MHz and for carriers of 20 MHz bandwidth when carrier center frequency is within the range 1895 – 1903 MHz.

NOTE 21: As exceptions, measurements with a level up to the applicable requirement of -38 dBm/MHz is permitted for each assigned E-UTRA carrier used in the measurement due to 2nd harmonic spurious emissions. An exception is allowed if there is at least one individual RB within the transmission bandwidth (see Figure 5.6-1) for which the 2nd harmonic totally or partially overlaps the measurement bandwidth (MBW).

NOTE 22: This requirement is applicable in the case of a 10 MHz E-UTRA carrier confined within 703 MHz and 733 MHz, otherwise the requirement of -25 dBm with a measurement bandwidth of 8 MHz applies.

NOTE 23: This requirement is applicable for 5 and 10 MHz E-UTRA channel bandwidth allocated within 718-728MHz. For carriers of 10 MHz bandwidth, this requirement applies for an uplink transmission bandwidth less than or equal to 30 RB with RBstart > 1 and RBstart<48.NOTE 24: Void

NOTE 25: Void

Table 6.6.3.2A-1: Requirements for intraband carrier aggregation

E-UTRA CA Configuration

Spurious emission

Protected band

Frequency range (MHz)

Maximum Level (dBm)

MBW (MHz)

NOTE

CA_1

E-UTRA Band 1, 7, 8, 11, 18, 19, 20, 21, 22, 26, 27, 28, 31, 32, 38, 40, 41, 42, 43, 44, 50, 51, 52, 65, 67, 72, 73, 74, 75, 76

NR Band n78, n79, n100, n101

FDL_low

FDL_high

-50

1

E-UTRA Band 3

FDL_low

FDL_high

-50

1

10

NR Band n77

FDL_low

FDL_high

-50

1

2

CA_3

E-UTRA Band 1, 7, 8, 20, 26, 27, 28, 31, 32, 33, 34, 38, 40, 41, 43, 44, 50, 51, 65, 67, 72, 73, 74, 75, 76

NR Band n79, n100, n101

FDL_low

FDL_high

-50

1

E-UTRA Band 3

FDL_low

FDL_high

-50

1

10

E-UTRA Band 22, 42, 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

CA_5

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 12, 13, 14, 17, 24, 25, 28, 29, 30, 31, 34, 38, 40, 42, 43, 45, 48, 54, 65, 66, 70, 71, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA band 52, 53

NR Band n77, n78,n79

FDL_low

FDL_high

-50

1

2

CA_7

E-UTRA Band 1, 3, 7, 8, 20, 22, 27, 28, 29, 30. 31, 32, 33, 34, 40, 42, 43, 50, 51, 52, 65, 67, 72, 74, 75, 76

NR Band n77, n78, n100, n101

FDL_low

FDL_high

-50

1

CA_8

E-UTRA Band 1, 20, 28, 31, 32, 33, 34, 38, 39, 40, 50, 51, 72, 73, 74, 75, 76

NR Band n100, n101

FDL_low

FDL_high

-50

1

E-UTRA band 3

FDL_low

FDL_high

-50

1

2

E-UTRA band 7

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

10

E-UTRA Band 22, 41, 42, 43, 52, 54

NR Band n77, n78,n79

FDL_low

FDL_high

-50

1

2

CA_38

E-UTRA Band 1,3, 8, 20, 22, 27, 28, 29, 30, 31, 32, 33, 34, 40, 42, 43, 50, 51, 52, 65, 67, 72, 74, 75, 76

NR Band n100, n101

FDL_low

FDL_high

-50

1

CA_39

E-UTRA Band 22, 34, 40, 41, 42, 44, 50, 51, 52, 73, 74

NR Band n79

FDL_low

FDL_high

-50

1

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

CA_40

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 20, 21, 22, 26, 27, 28, 31, 32, 33, 34, 38, 39, 41, 42, 43, 44, 50, 51, 52, 65, 67, 72, 73, 74, 75, 76

NR Band n77, n78, n100, n101

FDL_low

FDL_high

-50

1

NR Band n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

15

CA_41

E-UTRA Band 1, 2, 3, 4, 5, 8, 12, 13, 14, 17, 24, 25, 26, 27, 28, 29, 30, 34, 39, 40, 42, 44, 50, 51, 52, 54, 65, 66, 70, 71, 73, 74, 85, 103

NR Band n77, n78

FDL_low

FDL_high

-50

1

NR Band n79

FDL_low

FDL_high

-50

1

2

CA_42

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 11, 18, 19, 20, 21, 25, 26, 27, 28, 31, 32, 33, 34, 38, 40, 41, 44, 50, 51, 65, 66, 67, 72, 73, 74, 75, 76

NR Band n79, n100, n101

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

CA_48

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 26, 29, 30, 41, 50, 51, 54, 66, 70, 71, 74, 85, 103

FDL_low

FDL_high

-50

1

CA_66

E-UTRA Band 2, 4, 5, 7, 12, 13, 14, 17, 24, 25, 26, 27, 28, 29, 30, 38, 41, 43, 50, 51, 66, 70, 71, 74, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 42, 48

NR Band n77

FDL_low

FDL_high

-50

1

2

NOTE 1: FDL_low and FDL_high refer to each E-UTRA frequency band specified in Table 5.5-1

NOTE 2: As exceptions, measurements with a level up to the applicable requirements defined in Table 6.6.3.1-2 are permitted for each assigned E-UTRA carrier used in the measurement due to 2nd, 3rd, 4th [or 5th] harmonic spurious emissions. Due to spreading of the harmonic emission the exception is also allowed for the first 1 MHz frequency range immediately outside the harmonic emission on both sides of the harmonic emission. This results in an overall exception interval centred at the harmonic emission of (2MHz + N x LCRB x 180kHz), where N is 2, 3, 4, [5] for the 2nd, 3rd, 4th [or 5th] harmonic respectively. The exception is allowed if the measurement bandwidth (MBW) totally or partially overlaps the overall exception interval

NOTE 3: To meet these requirements some restriction will be needed for either the operating band or protected band

NOTE 4: N/A

NOTE 5: N/A

NOTE 6: N/A

NOTE 7: N/A

NOTE 8: N/A

NOTE 9: N/A

NOTE 10: The requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 and Table 6.6.3.1A-1 from the edge of the aggregated channel bandwidth.

NOTE 11: N/A

NOTE 12: N/A

NOTE 13: N/A

NOTE 14: N/A

NOTE 15: Applicable when co-existence with PHS system operating in 1884.5 -1915.7MHz.

Table 6.6.3.2A-2: Requirements for intraband non-contiguous CA

E-UTRA CA Configuration

Spurious emission

Protected band

Frequency range (MHz)

Maximum Level (dBm)

MBW (MHz)

NOTE

CA_4-4

E-UTRA Band 2, 4, 5, 10, 12, 13, 14, 17, 24, 25, 26, 27, 28, 29, 30, 41, 43, 50, 51, 53, 66, 70, 71, 74, 85, 103

FDL_low

FDL_high

-50

1

E-UTRA Band 22, 42,

NR Band n7

FDL_low

FDL_high

-50

1

2

NOTE 1: FDL_low and FDL_high refer to each E-UTRA frequency band specified in Table 5.5-1

NOTE 2: As exceptions, measurements with a level up to the applicable requirements defined in Table 6.6.3.1-2 are permitted for each assigned E-UTRA carrier used in the measurement due to 2nd or 3rd harmonic spurious emissions. Due to spreading of the harmonic emission the exception is also allowed for the first 1 MHz frequency range immediately outside the harmonic emission on both sides of the harmonic emission. This results in an overall exception interval centred at the harmonic emission of (2MHz + N x LCRB x 180kHz), where N is 2 or 3 for the 2nd or 3rd harmonic respectively. The exception is allowed if the measurement bandwidth (MBW) totally or partially overlaps the overall exception interval.

6.6.3.3 Additional spurious emissions

These requirements are specified in terms of an additional spectrum emission requirement. Additional spurious emission requirements are signalled by the network to indicate that the UE shall meet an additional requirement for a specific deployment scenario as part of the cell handover/broadcast message.

NOTE: For measurement conditions at the edge of each frequency range, the lowest frequency of the measurement position in each frequency range should be set at the lowest boundary of the frequency range plus MBW/2. The highest frequency of the measurement position in each frequency range should be set at the highest boundary of the frequency range minus MBW/2. MBW denotes the measurement bandwidth defined for the protected band.

6.6.3.3.1 Minimum requirement (network signalled value "NS_05")

When "NS_05" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.1-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.1-1: Additional requirements (PHS)

Frequency band

(MHz)

Channel bandwidth / Spectrum emission limit (dBm)

Measurement bandwidth

NOTE

5

MHz

10

MHz

15

MHz

20

MHz

1884.5 f 1915.7

-41

-41

-41

-41

300 KHz

1

Table 6.6.3.3.1-2: Void

6.6.3.3.2 Minimum requirement (network signalled value “NS_07”)

When "NS_07" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.2-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.2-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth / Spectrum emission limit (dBm)

Measurement bandwidth

10 MHz

769 ≤ f ≤ 775

-57

6.25 kHz

NOTE: The emissions measurement shall be sufficiently power averaged to ensure standard standard deviation < 0.5 dB.

6.6.3.3.3 Minimum requirement (network signalled value “NS_08”)

When “NS 08” is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.3-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.3-1: Additional requirement

Frequency band

(MHz)

Channel bandwidth / Spectrum emission limit (dBm)

Measurement bandwidth

5MHz

10MHz

15MHz

860 ≤ f ≤ 890

-40

-40

-40

1 MHz

6.6.3.3.4 Minimum requirement (network signalled value “NS_09”)

When “NS 09” is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.4-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.4-1: Additional requirement

Frequency band

(MHz)

Channel bandwidth / Spectrum emission limit (dBm)

Measurement bandwidth

5MHz

10MHz

15MHz

1475.9 ≤ f ≤ 1510.9

-35

-35

-35

1 MHz

NOTE 1: Void.

NOTE 2: To improve measurement accuracy, A-MPR values for NS_09 specified in Table 6.2.4-1 in subclause 6.2.4 are derived based on 100 kHz RBW.

6.6.3.3.5 Minimum requirement (network signalled value "NS_12")

When “NS 12” is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.5-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.5-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth /

Spectrum emission limit

(dBm)

Measurement bandwidth

1.4 MHz, 3 MHz, 5 MHz, 10 MHz, 15 MHz

806 ≤ f ≤ 813.5

-42

6.25 kHz

NOTE 1: The requirement applies for E-UTRA carriers with lower channel edge at or above 814.2 MHz.

NOTE 2: The emissions measurement shall be sufficiently power averaged to ensure a standard deviation < 0.5 dB.

6.6.3.3.6 Minimum requirement (network signalled value “NS_13”)

When “NS 13” is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.6-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.6-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth /

Spectrum emission limit

(dBm)

Measurement bandwidth

1.4, 3, 5 MHz

806 ≤ f ≤ 816

-42

6.25 kHz

NOTE 1: The requirement applies for E-UTRA carriers with lower channel edge at or above 819 MHz.

NOTE 2: The emissions measurement shall be sufficiently power averaged to ensure a standard deviation < 0.5 dB.

6.6.3.3.7 Minimum requirement (network signalled value “NS_14”)

When “NS 14” is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.7-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.7-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth /

Spectrum emission limit

(dBm)

Measurement bandwidth

10 MHz, 15 MHz

806 ≤ f ≤ 816

-42

6.25 kHz

NOTE 1: The requirement applies for E-UTRA carriers with lower channel edge at or above 824 MHz.

NOTE 2: The emissions measurement shall be sufficiently power averaged to ensure a standard deviation < 0.5 dB.

6.6.3.3.8 Minimum requirement (network signalled value “NS_15”)

When “NS 15” is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.8-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.8-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth /

Spectrum emission limit

(dBm)

Measurement bandwidth

1.4 MHz, 3 MHz, 5 MHz, 10 MHz, 15 MHz

851 ≤ f ≤ 859

-53

6.25 kHz

NOTE 1: The emissions measurement shall be sufficiently power averaged to ensure a standard deviation < 0.5 dB.

6.6.3.3.9 Minimum requirement (network signalled value “NS_16”)

When “NS_16” is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.9-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.9-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth / Spectrum emission limit (dBm)

Measurement bandwidth

NOTE

1.4, 3, 5, 10 MHz

790 ≤ f ≤ 803

-32

1 MHz

6.6.3.3.10 Minimum requirement (network signalled value “NS_17”)

When “NS_17” is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.10-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.10-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth / Spectrum emission limit (dBm)

Measurement bandwidth

NOTE

5, 10 MHz

470 ≤ f ≤ 710

-26.2

6 MHz

1

NOTE 1: Applicable when the assigned E-UTRA carrier is confined within 718 MHz and 748 MHz and when the channel bandwidth used is 5 or 10 MHz.

6.6.3.3.11 Minimum requirement (network signalled value “NS_18”)

When “NS_18” is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.11-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.11-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth / Spectrum emission limit (dBm)

Measurement bandwidth

NOTE

5, 10, 15, 20 MHz

692-698

-26.2

6 MHz

6.6.3.3.12 Minimum requirement (network signalled value “NS_19”)

When “NS_19” is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.12-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.12-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth / Spectrum emission limit (dBm)

Measurement bandwidth

NOTE

3, 5, 10, 15, 20 MHz

662 ≤ f ≤ 694

-25

8 MHz

6.6.3.3.13 Minimum requirement (network signalled value “NS_11”)

When “NS_11” is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.13-1. These requirements also apply for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 and Table 6.6.3.1A-1 from the edge of the channel bandwidth.

Table 6.6.3.3.13-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth / Spectrum emission limit (dBm)

Measurement bandwidth

1.4, 3, 5, 10, 15, 20 MHz

E-UTRA Band 2

-50

1 MHz

1998 ≤ f ≤ 1999

-21

1 MHz

1997 ≤ f < 1998

-27

1 MHz

1996 ≤ f < 1997

-32

1 MHz

1995 ≤ f < 1996

-37

1 MHz

1990 ≤ f < 1995

-40

1 MHz

6.6.3.3.14 Minimum requirement (network signalled value “NS_20”)

When “NS_20” is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.14-1. These requirements also apply for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 and Table 6.6.3.1A-1 from the edge of the channel bandwidth.

Table 6.6.3.3.14-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth / Spectrum emission limit (dBm)

Measurement bandwidth

5, 10, 15, 20 MHz

1990 ≤ f < 1999

-40

1 MHz

1999 ≤ f ≤ 2000

-40

NOTE 1

NOTE 1: The measurement bandwidth is 1% of the applicable E-UTRA channel bandwidth.

6.6.3.3.15 Minimum requirement (network signalled value “NS_21”)

When “NS_21” is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.15-1. These requirements also apply for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 and Table 6.6.3.1A-1 from the edge of the channel bandwidth.

Table 6.6.3.3.15-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth / Spectrum emission limit (dBm)

Measurement bandwidth

5, 10 MHz

2200 ≤ f < 2288

-40

1 MHz

2288 ≤ f < 2292

-37

1 MHz

2292 ≤ f < 2296

-31

1 MHz

2296 ≤ f < 2300

-25

1 MHz

2320 ≤ f < 2324

-25

1 MHz

2324 ≤ f < 2328

-31

1 MHz

2328 ≤ f < 2332

-37

1 MHz

2332 ≤ f ≤ 2395

-40

1 MHz

6.6.3.3.16 Minimum requirement (network signalled value "NS_22")

When "NS 22" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.16-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.16-1: Additional requirement

Frequency band

(MHz)

Channel bandwidth / Spectrum emission limit (dBm)

MBW

5, 10, 15, 20 MHz

3400 ≤ f ≤ 3800

-23 (NOTE 1, NOTE 3)

5 MHz

-40 (NOTE 2)

1 MHz

NOTE 1: This requirement applies within an offset between 5 MHz and 25 MHz from the lower and from the upper edge of the channel bandwidth, whenever these frequencies overlap with the specified frequency band.

NOTE 2: This requirement applies from 3400 MHz to 25 MHz below the lower E-UTRA channel edge and from 25 MHz above the upper E-UTRA channel edge to 3800 MHz.

NOTE 3: This emission limit might imply risk of harmful interference to UE(s) operating in the protected operating band

6.6.3.3.17 Minimum requirement (network signalled value “NS_23”)

When "NS 23" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.17-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.17-1: Additional requirement

Frequency band

(MHz)

Channel bandwidth / Spectrum emission limit (dBm)

MBW

5, 10, 15, 20 MHz

3400 ≤ f ≤ 3800

-23 (NOTE 1, NOTE 4)

5 MHz

-40 (NOTE 2)

1 MHz

NOTE 1: This requirement applies within an offset between 5 MHz + Foffset_NS_23 and 25 MHz + Foffset_NS_23 from the lower and from the upper edges of the channel bandwidth, whenever these frequencies overlap with the specified frequency band.

NOTE 2: This requirement applies from 3400 MHz to 25 MHz + Foffset_NS_23 below the lower E-UTRA channel edge and from 25 MHz + Foffset_NS_23 above the upper E-UTRA channel edge to 3800 MHz.

NOTE 3: Foffset_NS_23 is:

0 MHz for 5 MHz channel BW,

5 MHz for 10 MHz channel BW,

9 MHz for 15 MHz channel BW and

12 MHz for 20 MHz channel BW.

NOTE 4: This emission limit might imply risk of harmful interference to UE(s) operating in the protected operating band

6.6.3.3.18 Void

Table 6.6.3.3.18-1: Void

6.6.3.3.19 Minimum requirement (network signalled value "NS_04")

When "NS 04" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.19-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.19-1: Additional requirements

Frequency band

Channel bandwidth / Spectrum emission limit (dBm)

Measurement bandwidth

5, 10, 15, 20 MHz

2490.5 MHz ≤ f < 2495 MHz

-13

1 MHz

9 kHz < f < 2490.5 MHz

-25

1 MHz

6.6.3.3.20 Minimum requirement (network signalled value “NS_24”)

When "NS_24" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.20-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.20-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth /

Spectrum emission limit

(dBm)

Measurement bandwidth

5 MHz, 10 MHz, 15 MHz, 20 MHz

Band 34

-50

MHz

NOTE 1: This requirement applies at a frequency offset equal or larger than 5 MHz from the upper edge of the channel bandwidth, whenever these frequencies overlap with the specified frequency band.

6.6.3.3.21 Minimum requirement (network signalled value “NS_25”)

When "NS_25" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.21-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.21-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth /

Spectrum emission limit

(dBm)

Measurement bandwidth

5 MHz, 10 MHz, 15 MHz, 20 MHz

Band 34

-40

MHz

NOTE 1: This requirement applies at a frequency offset equal or larger than 5 MHz from the upper edge of the channel bandwidth, whenever these frequencies overlap with the specified frequency band.

6.6.3.3.22 Minimum requirement (network signalled value “NS_26”)

When "NS_26" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.22-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.22-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth /

Spectrum emission limit

(dBm)

Measurement bandwidth

5 MHz, 10 MHz, 15 MHz

686 ≤ f ≤ 694

-25

8MHz

6.6.3.3.23 Minimum requirement (network signalled value “NS_27” and “NS_43”)

When "NS_27" or “NS_43” is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.23-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.23-1: Additional requirements

Frequency band

Channel bandwidth / Spectrum emission limit (dBm)

Measurement bandwidth

5, 10, 15, 20 MHz

9 kHz f 3530 MHz

-40

1 MHz

3720 MHz f 5th harmonic of the upper frequency edge of the UL operating band

6.6.3.3.24 Minimum requirement (network signalled value “NS_28”)

When "NS_28" is indicated in the cell, the power of any UE emission for E-UTRA channels assigned within 5150-5350 MHz and 5470-5725 MHz shall not exceed the levels specified in Table 6.6.3.3.24-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.24-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth /

Spectrum emission limit

(dBm)

Measurement bandwidth

20 MHz

47 ≤ f ≤ 74

-54

100 kHz

87.5 ≤ f ≤ 118

-54

100 kHz

174 ≤ f ≤ 230

-54

100 kHz

470 ≤ f ≤ 862

-54

100 kHz

1000 ≤ f ≤ 5150

-30

1 MHz

5350 ≤ f ≤ 5470

-30

1 MHz

5725 ≤ f ≤ 26000

-30

1 MHz

6.6.3.3.25 Minimum requirement (network signalled value “NS_29”)

When "NS_29" is indicated in the cell, the power of any UE emission for E-UTRA channels assigned within 5150-5350 and 5470-5725 MHz shall not exceed the levels specified in Table 6.6.3.3.25-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.25-1: Additional requirements

Centre

Frequency Fc

[MHz]

Protected range

[MHz]

Frequency difference Δf between centre frequency –

5240 (for Fc=5180, 5200, 5220, 5240)

5260 (for Fc=5260, 5280, 5300, 5320) (MHz)

Minimum requirement

[dBm]

Measurement bandwidth

5180, 5200, 5220, 5240

5135 ≤ f ≤ 5142

-26

1 MHz

5142 < f ≤ 5150

-18

5250 ≤ f < 5251

≥ 10 and < 11

10(10 – Δf)

5251 ≤ f < 5260

≥ 11 and < 20

-10 – 8/9(Δf – 11)

5260 ≤ f < 5266.7

≥ 20 and < 26.7

-18 – 1.2(Δf – 20)

5266.7 ≤ f ≤ 5365

-26

5260, 5280, 5300, 5320

5135 ≤ f ≤ 5233.3

-26

5233.3 < f ≤ 5240

≥ 20 and < 26.7

-18 – 1.2(Δf – 20)

5240 < f ≤ 5249

≥ 11 and < 20

-10 – 8/9(Δf – 11)

5249 < f ≤ 5250

≥ 10 and < 11

10(10 – Δf)

5350 ≤ f ≤ 5365

-26

5500, 5520, 5540, 5560, 5580, 5600, 5620, 5640, 5660, 5680, 5700

5455 ≤ f ≤ 5460

-26

5460 < f ≤ 5470

-19

5725 ≤ f < 5740

-19

5740 ≤ f ≤ 5745

-26

6.6.3.3.26 Minimum requirement (network signalled value “NS_30”)

When "NS_30" is indicated in the cell, the power of any UE emission for E-UTRA channels assigned within 5150-5350 MHz, 5470-5725 MHz and 5725-5850 MHz shall not exceed the levels specified in Table 6.6.3.3.26-1, Table 6.6.3.3.26-2 and Table 6.6.3.3.26-3, respectively. These requirements also apply for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.26-1: Additional requirements for E-UTRA channels assigned within 5150-5350 MHz

Frequency band

(MHz)

Channel bandwidth /

Spectrum emission limit

(dBm)

Measurement bandwidth

20 MHz

4500 ≤ f ≤ 5150

-41

1 MHz

5350 ≤ f ≤ 5460

-41

Table 6.6.3.3.26-2: Additional requirements for E-UTRA channels assigned within 5470-5725 MHz

Frequency band

(MHz)

Channel bandwidth /

Spectrum emission limit

(dBm)

Measurement bandwidth

20 MHz

4500 ≤ f ≤ 5150

-41

1 MHz

5350 ≤ f ≤ 5460

-41

5460 < f ≤ 5470

-27

5725 ≤ f

-27

Table 6.6.3.3.26-3: Additional requirements for E-UTRA channels assigned within 5725-5850 MHz

Frequency offset of measurement filter ‑3dB point, Δf

Frequency offset of measurement filter centre frequency, f_offset

Minimum requirement

[dBm]

Measurement bandwidth

0 MHz ≤ Δf < 5 MHz

0.5 MHz ≤ f_offset < 5.5 MHz

27 – 2.28(f_offset/MHz – 0.5)

1 MHz

5 MHz ≤ Δf < 25 MHz

5.5 MHz ≤ f_offset < 25.5 MHz

15.6 – 0.28(f_offset/MHz – 0.5)

1 MHz

25 MHz ≤ Δf < 75 MHz

25.5 MHz ≤ f_offset < 75.5 MHz

10 – 0.74(f_offset/MHz – 0.5)

1 MHz

75 MHz ≤ Δf

75.5 MHz ≤ f_offset

-27

1 MHz

NOTE 1: The frequency offset f_offset is below and above the range 5725-5850 MHz; the measurement filter ‑3dB point is that closest to the range 5725-5850 MHz

NOTE 2: The requirement applies when the offset of the measurement filter centre frequency is such that both -3 dB points of the measurement filter are confined within the frequency range 5725-5850 MHz.

6.6.3.3.27 Minimum requirement (network signalled value “NS_31”)

When "NS_31" is indicated in the cell, the power of any UE emission for E-UTRA channels assigned within 5150-5250 MHz, 5250-5350 MHz, 5470-5725 MHz and 5725-5850 MHz shall not exceed the levels specified in Table 6.6.3.3.27-1, Table 6.6.3.3.27-2, Table 6.6.3.3.27-3 and Table 6.6.3.3.27-4, respectively. These requirements also apply for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.27-1: Additional requirements for E-UTRA channels assigned within 5150-5250 MHz

Frequency band

(MHz)

Channel bandwidth /

Spectrum emission limit

(dBm)

Measurement bandwidth

20 MHz

f ≤ 5150

-27

1 MHz

f ≥ 5250

-27

Table 6.6.3.3.27-2: Additional requirements for E-UTRA channels assigned within 5250-5350 MHz

Frequency band

(MHz)

Channel bandwidth /

Spectrum emission limit

(dBm)

Measurement bandwidth

20 MHz

f ≤ 5250

-27

1 MHz

f ≥ 5350

-27

Table 6.6.3.3.27-3: Additional requirements for E-UTRA channels assigned within 5470-5725 MHz

Frequency band

(MHz)

Channel bandwidth /

Spectrum emission limit

(dBm)

Measurement bandwidth

20 MHz

f ≤ 5470

-27

1 MHz

f ≥ 5725

-27

Table 6.6.3.3.27-4: Additional requirements for E-UTRA channels assigned within 5725-5850 MHz

Frequency band

(MHz)

Channel bandwidth /

Spectrum emission limit

(dBm)

Measurement bandwidth

20 MHz

f ≤ 5725

-27

1 MHz

f ≥ 5850

-27

6.6.3.3.28 Minimum requirement (network signalled value “NS_36”)

When "NS_36" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.28-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.28-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth /

Spectrum emission limit

(dBm)

Measurement bandwidth

5 MHz, 10 MHz and 15 MHz

470 ≤ f ≤ 694

-42

8MHz

NOTE: For a 5 MHz E-UTRA carrier confined within 698MHz and 703MHz, this requirement shall be met in normal conditions only. The requirement is relaxed to -30dBm in extreme conditions.

6.6.3.3.29 Minimum requirement (network signalled value “NS_38”)

When "NS_38" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.29-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.29-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth /

Spectrum emission limit

(dBm)

Measurement bandwidth

1.4 MHz, 3 MHz, 5 MHz, 10 MHz, 15 MHz, 20 MHz

1400 ≤ f ≤ 1427

-32

27MHz

NOTE 1: This requirement shall be verified with UE transmission power of 15 dBm.

6.6.3.3.30 Minimum requirement (network signalled value “NS_39”)

When "NS_39" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.30-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.30-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth /

Spectrum emission limit

(dBm)

Measurement bandwidth

1.4 MHz, 3 MHz, 5 MHz, 10 MHz, 15 MHz, 20 MHz

1475 ≤ f ≤ 1488

-28

1MHz

6.6.3.3.31 Minimum requirement (network signalled value “NS_40” and “NS_41”)

When "NS_40" or "NS_41" is indicated in the cell, the power of any UE emission for E-UTRA channels assigned within 1427-1432MHz (B51) and 1432-1452MHz (B50) shall not exceed the levels specified in Table 6.6.3.3.31-1. These requirements also apply for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.31-1: Additional requirements for E-UTRA channels assigned within 1427-1452MHz

Frequency band

(MHz)

Channel bandwidth /

Spectrum emission limit

(dBm)

Measurement bandwidth

3, 5, 10, 15,

20 MHz

1400 ≤ f ≤ 1427

-32

27 MHz

NOTE 1: This requirement shall be verified with UE transmission power of 15 dBm.

6.6.3.3.32 Minimum requirement (network signalled value “NS_42”)

When "NS_42" is indicated in the cell, the power of any UE emission for E-UTRA channels assigned within 1492-1517 MHz (B50) shall not exceed the levels specified in Table 6.6.3.3.32-1. These requirements also apply for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.32-1: Additional requirements for E-UTRA channels assigned within 1492-1517 MHz

Frequency band

(MHz)

Channel bandwidth /

Spectrum emission limit

(dBm)

Measurement bandwidth

3, 5, 10, 15,

20 MHz

1518 ≤ f ≤ 1559

-30

1 MHz

6.6.3.3.33 Minimum requirement (network signalled value “NS_44”)

When "NS_44" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.33-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.33-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth / Spectrum emission limit (dBm)

Measurement bandwidth

NOTE

5, 10, 15, 20

2620-2645

-15.5

5MHz

1

2645-2690

-40

1MHz

1

Note 1: The E-UTRA carrier with channel bandwidth is confined within 2570 MHz and 2615 MHz

6.6.3.3.34 Minimum requirement (network signalled value “NS_45”)

When "NS_45" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Tables 6.6.3.3.35-1 and 6.6.3.3.35-2. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.34-1: Additional requirements for 1.4, 3 and 5 MHz channel bandwidths

Frequency band

(MHz)

Channel bandwidth / Spectrum emission limit (dBm)

Measurement bandwidth

NOTE

1.4, 3, 5

0.009 < f ≤ 2477.5

-25

1 MHz

2477.5 < f ≤ 2478.5

-13

1 MHz

2478.5< f ≤ 2483.5

-10

1 MHz

2495 ≤ f < 2496

-13

1% of Channel Bandwidth

2496< f ≤ 2501

-13

1 MHz

2501 ≤ f ≤ 5th harmonic of the upper frequency edge of the UL operating band

-25

1 MHz

Table 6.6.3.3.34-2: Additional requirements for 10 MHz channel bandwidth

Frequency band

(MHz)

Channel bandwidth / Spectrum emission limit (dBm)

Measurement bandwidth

NOTE

10

0.009 < f ≤ 2473.5

-25

1 MHz

2473.5 < f ≤ 2478.5

-13

1 MHz

2478.5< f ≤ 2483.5

-10

1 MHz

2495 ≤ f < 2496

-13

1% of Channel Bandwidth

2496< f ≤ 2505

-13

1 MHz

2505 ≤ f ≤ 5th harmonic of the upper frequency edge of the UL operating band

-25

1 MHz

6.6.3.3.35 Minimum requirement (network signalled value “NS_56”)

When "NS_56" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.35-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.35-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth / Spectrum emission limit1 (dBm)

Measurement bandwidth

NOTE

5 MHz, 10MHz

1541 ≤ f ≤ 1559

-102

2kHz

Averaged over any 2 millisecond active transmission interval

1559≤ f ≤ 1608

-85

700Hz

1608≤ f ≤ 1610

-85 +5/2 (f-1608)

700Hz

1610≤ f ≤ 1625

-80+ 66/15 (f-1610)

700Hz

1541 ≤ f ≤ 1608

-75

1MHz

Averaged over any 2 millisecond active transmission interval

1608≤ f ≤ 1610

-75 + 5/2 (f-1608)

1MHz

1610≤ f ≤ 1627.5

-70+ 57/17.5 (f-1610)

1MHz

1627.5

-37

4kHz

1638.5 ≤f ≤ 1645.5

-28

4kHz

1657.5 ≤f ≤ 1660.5

-28

4kHz

NOTE 1: The EIRP requirement in regulation is converted to conducted requirement using a 0 dBi antenna.

6.6.3.3.36 Minimum requirement (network signalled value “NS_62”)

When "NS_62" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3.36-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 from the edge of the channel bandwidth.

Table 6.6.3.3.36-1: Additional requirements

Frequency band

(MHz)

Channel bandwidth / Spectrum emission limit (dBm)

Measurement bandwidth

NOTE

1.4 MHz, 3 MHz and 5 MHz

1541 ≤ f ≤ 1559

-102

2kHz

Averaged over any 2 millisecond active transmission interval

1559≤ f ≤ 1608

-85

700Hz

1608≤ f ≤ 1610

-85 +5/2 (f-1608)

700Hz

1610≤ f ≤ 1625

-80+ 66/15 (f-1610)

700Hz

1541 ≤ f ≤ 1608

-75

1MHz

Averaged over any 2 millisecond active transmission interval

1608≤ f ≤ 1610

-75 + 5/2 (f-1608)

1MHz

1610≤ f ≤ 1625

-70+ 66/15 (f-1610)

1MHz

NOTE 1: The EIRP requirement in regulation is converted to conducted requirement using 0 dBi antenna.

6.6.3.3A Additional spurious emissions for CA

These requirements are specified in terms of an additional spectrum emission requirement. Additional spurious emission requirements are signalled by the network to indicate that the UE shall meet an additional requirement for a specific deployment scenario as part of the cell reconfiguration message.

NOTE: For measurement conditions at the edge of each frequency range, the lowest frequency of the measurement position in each frequency range should be set at the lowest boundary of the frequency range plus MBW/2. The highest frequency of the measurement position in each frequency range should be set at the highest boundary of the frequency range minus MBW/2. MBW denotes the measurement bandwidth defined for the protected band.

6.6.3.3A.1 Minimum requirement for CA_1C (network signalled value "CA_NS_01")

When "CA_NS_01" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3A.1-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1A-1 from the edge of the aggregated channel bandwidth.

Table 6.6.3.3A.1-1: Additional requirements (PHS)

Protected band

Frequency range (MHz)

Maximum Level (dBm)

MBW (MHz)

NOTE

E-UTRA band 34

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

1

NOTE 1: Applicable when the aggregated channel bandwidth is confined within frequency range 1940 – 1980 MHz

6.6.3.3A.2 Minimum requirement for CA_1C (network signalled value "CA_NS_02")

When "CA_NS_02" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3A.2-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1A-1 from the edge of the aggregated channel bandwidth.

Table 6.6.3.3A.2-1: Additional requirements

Protected band

Frequency range (MHz)

Maximum Level (dBm)

MBW (MHz)

NOTE

E-UTRA band 34

FDL_low

FDL_high

-50

1

Frequency range

1900

1915

-15.5

5

1, 2

Frequency range

1915

1920

+1.6

5

1, 2

NOTE 1: The requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 and Table 6.6.3.1A-1 from the edge of the channel bandwidth.

NOTE 2: For these adjacent bands, the emission limit could imply risk of harmful interference to UE(s) operating in the protected operating band.

6.6.3.3A.3 Minimum requirement for CA_1C (network signalled value "CA_NS_03")

When "CA_NS_03" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3A.3-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1A-1 from the edge of the aggregated channel bandwidth.

Table 6.6.3.3A.3-1: Additional requirements

Protected band

Frequency range (MHz)

Maximum Level (dBm)

MBW (MHz)

NOTE

E-UTRA band 34

FDL_low

FDL_high

-50

1

Frequency range

1880

1895

-40

1

Frequency range

1895

1915

-15.5

5

1, 2

Frequency range

1915

1920

+1.6

5

1, 2

NOTE 1: The requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 and Table 6.6.3.1A-1 from the edge of the channel bandwidth.

NOTE 2: For these adjacent bands, the emission limit could imply risk of harmful interference to UE(s) operating in the protected operating band.

6.6.3.3A.4 Minimum requirement for CA_38C (network signalled value "CA_NS_05")

When "CA_NS_05" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3A.4-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1A-1 from the edge of the aggregated channel bandwidth. This requirement is applicable for carriers with aggregated channel bandwidths confined in 2570 – 2615 MHz.

Table 6.6.3.3A.4-1: Additional requirements

Protected band

Frequency range (MHz)

Maximum Level (dBm)

MBW (MHz)

NOTE

Frequency range

2620

2645

-15.5

5

1, 2, 3

Frequency range

2645

2690

-40

1

1, 3

NOTE 1: The requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 and Table 6.6.3.1A-1 from the edge of the channel bandwidth.

NOTE 2: For these adjacent bands, the emission limit could imply risk of harmful interference to UE(s) operating in the protected operating band.

NOTE 3: This requirement is applicable for carriers with aggregated channel bandwidths confined in 2570-2615 MHz.

6.6.3.3A.5 Minimum requirement for CA_7C (network signalled value "CA_NS_06")

When "CA_NS_06" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3A.5-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1A-1 from the edge of the aggregated channel bandwidth.

Table 6.6.3.3A.5-1: Additional requirements

Protected band

Frequency range (MHz)

Maximum Level (dBm)

MBW (MHz)

NOTE

Frequency range

2570

2575

+1.6

5

1, 2

Frequency range

2575

2595

-15.5

5

1, 2

Frequency range

2595

2620

-40

1

NOTE 1: The requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 and Table 6.6.3.1A-1 from the edge of the channel bandwidth.

NOTE 2: For these adjacent bands, the emission limit could imply risk of harmful interference to UE(s) operating in the protected operating band.

6.6.3.3A.6 Minimum requirement for CA_39C and CA_39C-41A (network signalled value "CA_NS_07")

When "CA_NS_07" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3A.6-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1A-1 from the edge of the aggregated channel bandwidth.

Table 6.6.3.3A.6-1: Additional requirements

Protected band

Frequency range (MHz)

Maximum Level (dBm)

MBW (MHz)

NOTE

Frequency range

1805

1855

-40

1

1

Frequency range

1855

1880

-15.5

5

1, 2, 3

NOTE 1: This requirement is applicable for carriers with aggregated channel bandwidths confined in 1885-1920 MHz.

NOTE 2: The requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1 and Table 6.6.3.1A-1 from the edge of the channel bandwidth.

NOTE 3: For these adjacent bands, the emission limit could imply risk of harmful interference to UE(s) operating in the protected operating band.

6.6.3.3A.7 Minimum requirement for CA_42C (network signalled value "CA_NS_08")

When "CA_NS_08" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3A.7-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1A-1 from the edge of the aggregated channel bandwidth.

Table 6.6.3.3A.7-1: Additional requirements

Frequency band

(MHz)

Aggregated bandwidth / Spectrum emission limit (dBm)

MBW

25, 30, 35, 40 MHz (Note 1)

3400 ≤ f ≤ 3800

-23 (Note 2, Note 4)

5 MHz

-40 (Note 3)

1 MHz

NOTE 1: Possible aggregated bandwidth for CA_42C as specified in Table 5.6A.1-1.

NOTE 2: This requirement applies within an offset between 5 MHz and 25 MHz from the lower and from the upper edge of the channel bandwidth, whenever these frequencies overlap with the specified frequency band.

NOTE 3: This requirement applies from 3400 MHz to 25 MHz below the lower E-UTRA channel edge and from 25 MHz above the upper E-UTRA channel edge to 3800 MHz.

NOTE 4: This emission limit might imply risk of harmful interference to UE(s) operating in the protected operating band.

6.6.3.3A.8 Minimum requirement for CA_41C and CA_41D (network signalled value "CA_NS_04")

When "CA_NS_04" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3A.8-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1A-1 from the edge of the aggregated channel bandwidth.

Table 6.6.3.3A.8-1: Additional requirements

Frequency band

Spectrum emission limit (dBm)

Measurement bandwidth

2490.5 MHz ≤ f < 2495 MHz

-13

1 MHz

9 kHz < f < 2490.5 MHz

-25

1 MHz

6.6.3.3A.9 Void
6.6.3.3A.10 Minimum requirement for CA_48B and CA_48C (network signalled value "CA_NS_10")

When "CA_NS_10" is indicated in the cell, the power of any UE emission shall not exceed the levels specified in Table 6.6.3.3A.10-1. This requirement also applies for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1A-1 from the edge of the aggregated channel bandwidth.

Table 6.6.3.3A.10-1: Additional requirements

Frequency range

(MHz)

Aggregated bandwidth / Spectrum emission limit (dBm)

Measurement bandwidth

5, 10, 15, 20, 40 MHz

9 kHz – 3530 MHz

-40

1 MHz

3530 MHz – 3540 MHz

-25

3710 MHz – 3720 MHz

-25

3720 MHz – 12.75 GHz

-40