6.3.3A UE Transmit OFF power for CA
36.1013GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Release 18TSUser Equipment (UE) radio transmission and reception
For inter-band carrier aggregation with uplink assigned to two E-UTRA bands and intra-band contiguous and non-contiguous carrier aggregation, transmit OFF power is defined as the mean power per component carrier when the transmitter is OFF on all component carriers. The transmitter is considered to be OFF when the UE is not allowed to transmit or during periods when the UE is not transmitting a sub-frame. During measurements gaps, the UE is not considered to be OFF.
6.3.3A.1 Minimum requirement for CA
For inter-band carrier aggregation with uplink assigned to two E-UTRA bands, transmit OFF power requirement is defined per carrier and the requirement is specified in subclause 6.3.3.1. If two contiguous component carriers are assigned to one E-UTRA band, the requirements in subclause 6.3.3A.1 apply for those component carriers.
For intra-band contiguous and non-contiguous carrier aggregation the transmit OFF power is defined as the mean power in a duration of at least one sub-frame (1ms) excluding any transient periods. The transmit OFF power shall not exceed the values specified in Table 6.3.3A.1-1.
Table 6.3.3A.1-1: Transmit OFF power for intra-band contiguous and non-contiguos CA UE
CC Channel bandwidth / Transmit OFF power / Measurement bandwidth |
||||||
1.4 MHz |
3.0 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
|
Transmit OFF power |
-50 dBm |
|||||
Measurement bandwidth |
2.7 MHz |
4.5 MHz |
9.0 MHz |
13.5 MHz |
18 MHz |