6.3.2A UE Minimum output power for CA
36.1013GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Release 18TSUser Equipment (UE) radio transmission and reception
For inter-band carrier aggregation with uplink assigned to two E-UTRA bands and intra-band contiguous and non-contiguous carrier aggregation, the minimum controlled output power of the UE is defined as the transmit power of the UE per component carrier, i.e., the power in the channel bandwidth of each component carrier for all transmit bandwidth configurations (resource blocks), when the power on both component carriers are set to a minimum value.
6.3.2A.1 Minimum requirement for CA
For inter-band carrier aggregation with uplink assigned to two E-UTRA bands, the minimum output power is defined per carrier and the requirement is specified in subclause 6.3.2.1. If two contiguous component carriers are assigned to one E-UTRA band, the requirements in subclause 6.3.2A.1 apply for those component carriers.
For intra-band contiguous and non-contiguous carrier aggregation the minimum output power is defined as the mean power in one sub-frame (1ms). The minimum output power shall not exceed the values specified in Table 6.3.2A.1-1.
Table 6.3.2A.1-1: Minimum output power for intra-band contiguous and non-contiguous CA UE
CC Channel bandwidth / Minimum output power / Measurement bandwidth |
||||||
1.4 MHz |
3.0 MHz |
5 MHz |
10 MHz |
15 MHz |
20 MHz |
|
Minimum output power |
-40 dBm |
|||||
Measurement bandwidth |
2.7 MHz |
4.5 MHz |
9.0 MHz |
13.5 MHz |
18 MHz |