6.2.5F Configured transmitted Power for category NB1 and NB2

36.1013GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Release 18TSUser Equipment (UE) radio transmission and reception

For each slot i the category NB1and NB2 UE is allowed to set its configured maximum output power PCMAX,c. The configured maximum output power PCMAX,c is set within the following bounds:

PCMAX_L,c ≤ PCMAX,c ≤ PCMAX_H,c

Where

 PCMAX_L,c = MIN { PEMAX,c , PPowerClass – MPRc – A-MPRc}

 PCMAX_H,c = MIN { PEMAX,c, PPowerClass}

 PEMAX,c is the value given to IE P-Max, defined in [7]

 PPowerClass is the maximum category NB1 and NB2 UE power specified in Table 6.2.2F-1 without taking into account the associated tolerance

 MPRc is specified in subclause 6.2.3F

 A-MPRc = 0dB unless otherwise stated.

The measurement period for PUMAX,c is at least one sub-frame (1ms) for 15 KHz channel spacing, and at least a 2ms slot (excluding the 2304Ts gap when UE is not transmitting) respectively for the 3.75 KHz channel spacing. The measured maximum output power PUMAX,c shall be within the following bounds:

PCMAX_L,c – T(PCMAX_L,c) ≤ PUMAX,c ≤ PCMAX_H,c + T(PCMAX_H,c)

Where T(PCMAX) is defined by the tolerance table below and applies to PCMAX_L,c and PCMAX_H,c separately.

Table 6.2.5F-1: PCMAX tolerance for power class 3

PCMAX (dBm)

Tolerance T(PCMAX) (dB)

21 ≤ PCMAX ≤ 23

2.0

20 ≤ PCMAX < 21

2.5

19 ≤ PCMAX < 20

3.5

18 ≤ PCMAX < 19

4.0

13 ≤ PCMAX < 18

5.0

8 ≤ PCMAX < 13

6.0

-40 ≤ PCMAX < 8

7.0

Table 6.2.5F-2: PCMAX tolerance for power class 5

PCMAX,c
(dBm)

Tolerance T(PCMAX,c)
(dB)

18 ≤ PCMAX ≤ 20

2.0

17 ≤ PCMAX,c < 18

2.5

16 ≤ PCMAX,c < 17

3.5

15 ≤ PCMAX,c < 16

4.0

10 ≤ PCMAX,c < 15

5.0

5 ≤ PCMAX,c < 10

6.0

-40 ≤ PCMAX,c < 5

7.0

Table 6.2.5F-3: PCMAX tolerance for power class 6

PCMAX,c
(dBm)

Tolerance T(PCMAX,c)
(dB)

13 ≤ PCMAX,c ≤ 14

2.5

12 ≤ PCMAX,c < 13

3.5

11 ≤ PCMAX,c < 12

4

8 ≤ PCMAX,c < 11

5

5 ≤ PCMAX,c < 8

6.0

-40 ≤ PCMAX,c < 5

7.0