6.2.4B UE maximum output power with additional requirements for UL-MIMO
36.1013GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Release 18TSUser Equipment (UE) radio transmission and reception
For UE with two transmit antenna connectors in closed-loop spatial multiplexing scheme, the A-MPR values specified in subclause 6.2.4 shall apply to the maximum output power specified in Table 6.2.2B-1. The requirements shall be met with the UL-MIMO configurations specified in Table 6.2.2B-2. For UE supporting UL-MIMO, the maximum output power is measured as the sum of the maximum output power at each UE antenna connector. Unless stated otherwise, an A-MPR of 0 dB shall be used.
For the UE maximum output power modified by A-MPR, the power limits specified in subclause 6.2.5B apply.
If UE is configured for transmission on single-antenna port, the requirements in subclause 6.2.4 apply.