6.2.3F UE maximum output power for modulation / channel bandwidth for category NB1 and NB2

36.1013GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Release 18TSUser Equipment (UE) radio transmission and reception

For UE category NB1 and NB2 power class 3 and 5 the allowed Maximum Power Reduction (MPR) for the maximum output power given in Table 6.2.2F-1 is specified in Table 6.2.3F-1.

Table 6.2.3F-1: Maximum Power Reduction (MPR) for UE category NB1 and NB2 Power Class 3 and 5

Modulation

QPSK

16-QAM

Tone positions for 3 Tones allocation

0-2

3-5 and 6-8

9-11

0-2, 3-5, 6-8, and 9-11

MPR

≤ 0.5 dB

0 dB

≤ 0.5 dB

≤ 1.8 dB

Tone positions for 6 Tones allocation

0-5 and 6-11

0-5 and 6-11

MPR

≤ 1 dB

≤ 1 dB

≤ 1.8 dB

Tone positions for 12 Tones allocation

0-11

0-11

MPR

≤ 2 dB

≤ 2.8 dB

For UE category NB1 and NB2 power class 6 the allowed Maximum Power Reduction (MPR) for the maximum output power given in Table 6.2.2F-1 is specified in Table 6.2.3F-2.

Table 6.2.3F-2: Maximum Power Reduction (MPR) for UE category NB1 and NB2 Power Class 6

Modulation

QPSK

16-QAM

MPR for 3 Tones allocation

≤ 0.5 dB

≤ 1.7 dB

MPR for 6 Tones allocation

≤ 1 dB

≤ 1.6 dB

MPR for 12 Tones allocation

≤ 1.5 dB

≤ 2.6 dB

For the UE maximum output power modified by MPR, the power limits specified in sub-clause 6.2.5F apply.