6.2.2E UE maximum output power for Category M1 and M2 UE

36.1013GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Release 18TSUser Equipment (UE) radio transmission and reception

The following UE Power Classes define the maximum output power for any transmission bandwidth within the channel bandwidth for non CA configuration and UL-MIMO unless otherwise stated. The period of measurement shall be at least one sub frame (1ms).

Table 6.2.2E-1: UE Power Class

EUTRA band

Class 2

(dBm)

Tolerance

(dB)

Class 3 (dBm)

Tolerance (dB)

Class 5 (dBm)

Tolerance (dB)

Class 6 (dBm)

Tolerance (dB)

1

23

±2

20

±2

14

±2.5

2

23

±22

20

±22

14

±2.5

3

23

±22

20

±22

14

±2.5

4

23

±2

20

±2

14

±2.5

5

23

±2

20

±2

14

±2.5

7

23

±22

20

±22

14

±2.5

8

23

±22

20

±22

14

±2.5

11

23

±2

20

±2

14

±2.5

12

23

±22

20

±22

14

±2.5

13

23

±2

20

±2

14

±2.5

14

23

±2

20

±2

14

±2.5

18

23

±25

20

±25

14

±2.5

19

23

±2

20

±2

14

±2.5

20

23

±22

20

±22

14

±2.5

21

23

±2

20

±2

14

±2.5

24

23

+2/-32

20

+2/-32

14

±2.5

25

23

±22

20

±2

14

±2.5

26

23

±22

20

±22

14

±2.5

27

23

±2

20

±2

14

±2.5

28

23

+2/-2.5

20

+2/-2.5

14

±2.5

31

267

±2

23

±2

20

±2

14

±2.5

39

23

±2

20

±2

14

±2.5

40

23

±22

20

±2

14

±2.5

41

23

±22

20

±22

14

±2.5

42

23

+2/-3

20

+2/-3

14

±2.5

43

23

+2/-3

20

+2/-3

14

±2.5

48

23

+2/-3

20

+2/-3

14

±2.5

71

23

±2

20

±2

14

±2.5

72

267

±2

23

±2

20

±2

14

±2.5

73

23

±2

20

±2

14

±2.5

74

23

±2

20

±2

14

±2.5

85

23

±22

20

±22

14

±2.5

87

23

±2

20

±2

14

±2.5

88

23

±2

20

±2

14

±2.5

NOTE 1: Void

NOTE 2: 2 refers to the transmission bandwidths (Figure 5.6-1) confined within FUL_low and FUL_low + 4 MHz or FUL_high – 4 MHz and FUL_high, the maximum output power requirement is relaxed by reducing the lower tolerance limit by 1.5 dB

NOTE 3: For the UE which supports both Band 11 and Band 21 operating frequencies, the tolerance is FFS.

NOTE 4: PPowerClass is the maximum UE power specified without taking into account the tolerance

NOTE 5: For a UE that supports both Band 18 and Band 26, the maximum output power requirement is relaxed by reducing the lower tolerance limit by 1.5 dB for transmission bandwidths confined within 815 MHz and 818 MHz.

NOTE 6: Void

NOTE 7: Applicable for category M1 and M2 HD-FDD UE