10 Performance requirement (MBMS)
36.1013GPPEvolved Universal Terrestrial Radio Access (E-UTRA)Release 18TSUser Equipment (UE) radio transmission and reception
10.1 FDD (Fixed Reference Channel)
The parameters specified in Table 10.1-1 are valid for all FDD tests unless otherwise stated. For the requirements defined in this section, the difference between CRS EPRE and the MBSFN RS EPRE should be set to 0 dB as the UE demodulation performance might be different when this condition is not met (e.g. in scenarios where power offsets are present, such as scenarios when reserved cells are present).
Table 10.1-1: Common Test Parameters (FDD)
Parameter |
Unit |
Value |
Number of HARQ processes |
Processes |
None |
Subcarrier spacing |
kHz |
15 kHz |
Allocated subframes per Radio Frame (Note 1) |
6 subframes |
|
Number of OFDM symbols for PDCCH |
2 |
|
Cyclic Prefix |
Extended |
|
Note1: For FDD mode, up to 6 subframes (#1/2/3/6/7/8) are available for MBMS, in line with TS 36.331. |
All tests specified in 10.1 and 10.3 the applicability rules are defined as the following. The requirements in clause 10.3 are applicable to UEs that support FeMBMS. The test case applicability is in according to Table 10.1-2 depending on set of supported UE capabilities.
Table 10.1-2: FeMBMS PMCH tests applicability
Tests / clause |
Applicable if UE indicates at least the following capability |
10.3.1 |
FeMBMS support of fembmsMixedCell and unicast-fembmsMixedSCell with corresponding subcarrier spacing |
10.3.2 |
FeMBMS support of fembmsMixedCell with corresponding subcarrier spacing |
10.3.3 |
FeMBMS support of fembmsDedicatedCell with corresponding subcarrier spacing |
For FeMBMS capable UEs, if corresponding tests listed in clause 10.1 or 10.3.1 or 10.3.2 are tested, the test coverage can be considered fulfilled without executing the corresponding tests listed in clause 10.3.3.
10.1.1 Minimum requirement
The receive characteristic of MBMS is determined by the BLER. The requirement is valid for all RRC states for which the UE has capabilities for MBMS.
For the parameters specified in Table 10.1-1 and Table 10.1.1-1 and Annex A.3.8.1, the average downlink SNR shall be below the specified value for the BLER shown in Table 10.1.1-2.
Table 10.1.1-1: Test Parameters for Testing
Parameter |
Unit |
Test 1-4 |
|
Downlink power allocation |
dB |
0 |
|
dB |
0 (Note 1) |
||
σ |
dB |
0 |
|
at antenna port |
dBm/15kHz |
-98 |
|
Note 1: . |
Table 10.1.1-2: Minimum performance
Test number |
Bandwidth |
Reference Channel |
OCNG Pattern |
Propagation condition |
Correlation Matrix and antenna |
Reference value |
MBMS UE Category |
|
BLER (%) |
SNR(dB) |
|||||||
1 |
10 MHz |
R.37 FDD |
OP.4 FDD |
MBSFN channel model (Table B.2.6-1) |
1×2 low |
1 |
4.1 |
≥1 |
2 |
10 MHz |
R.38 FDD |
OP.4 FDD |
11.0 |
≥1 |
|||
3 |
10 MHz |
R.39 FDD |
OP.4 FDD |
20.1 |
≥2 |
|||
5.0MHz |
R.39-1 FDD |
OP.4 FDD |
20.5 |
1 |
||||
4 |
1.4 MHz |
R.40 FDD |
OP.4 FDD |
6.6 |
≥1 |
10.2 TDD (Fixed Reference Channel)
The parameters specified in Table 10.2-1 are valid for all TDD tests unless otherwise stated. For the requirements defined in this section, the difference between CRS EPRE and the MBSFN RS EPRE should be set to 0 dB as the UE demodulation performance might be different when this condition is not met (e.g. in scenarios where power offsets are present, such as scenarios when reserved cells are present).
Table 10.2-1: Common Test Parameters (TDD)
Parameter |
Unit |
Value |
Number of HARQ processes |
Processes |
None |
Subcarrier spacing |
kHz |
15 kHz |
Allocated subframes per Radio Frame (Note 1) |
5 subframes |
|
Number of OFDM symbols for PDCCH |
2 |
|
Cyclic Prefix |
Extended |
|
Note1: For TDD mode, in line with TS 36.331, Uplink-Downlink Configuration 5 is proposed, up to 5 subframes (#3/4/7/8/9) are available for MBMS. |
10.2.1 Minimum requirement
The receive characteristic of MBMS is determined by the BLER. The requirement is valid for all RRC states for which the UE has capabilities for MBMS.
For the parameters specified in Table 10.2-1 and Table 10.2.1-1 and Annex A.3.8.2, the average downlink SNR shall be below the specified value for the BLER shown in Table 10.2.1-2.
Table 10.2.1-1: Test Parameters for Testing
Parameter |
Unit |
Test 1-4 |
|
Downlink power allocation |
dB |
0 |
|
dB |
0 (Note 1) |
||
σ |
dB |
0 |
|
at antenna port |
dBm/15kHz |
-98 |
|
Note 1: . |
Table 10.2.1-2: Minimum performance
Test number |
Bandwidth |
Reference Channel |
OCNG Pattern |
Propagation condition |
Correlation Matrix and antenna |
Reference value |
MBMS UE Category |
|
BLER (%) |
SNR(dB) |
|||||||
1 |
10 MHz |
R.37 TDD |
OP.4 TDD |
MBSFN channel model (Table B.2.6-1) |
1×2 low |
1 |
3.4 |
≥1 |
2 |
10 MHz |
R.38 TDD |
OP.4 TDD |
11.1 |
≥1 |
|||
3a |
10 MHz |
R.39 TDD |
OP.4 TDD |
20.1 |
≥2 |
|||
3b |
5MHz |
R.39-1 TDD |
OP.4 TDD |
20.5 |
1 |
|||
4 |
1.4 MHz |
R.40 TDD |
OP.4 TDD |
5.8 |
≥1 |
10.3 FDD (Fixed Reference Channel) with FeMBMS
For the requirements defined in this section, the difference between CRS EPRE and the MBSFN RS EPRE should be set to 0 dB for subcarrier spacing as 15kHz, 3dB for for subcarrier spacing as 7.5kHz and 10.8dB for for subcarrier spacing as 1.25kHz because the UE demodulation performance might be different when this condition is not met (e.g. in scenarios where power offsets are present, such as scenarios when reserved cells are present).
10.3.1 Minimum requirement for FeMBMS Unicast-mixed Cell under CA
10.3.1.1 Minimum requirement with 1.25kHz subcarrier spacing
The receive characteristic of MBMS is determined by the BLER. The requirement is valid for all RRC states for which the UE has capabilities for FeMBMS Unicast-mixed Cell under CA.
For the parameters specified in Table 10.3.1.1-1 and Annex A.3.8.1, the average downlink SNR shall be below the specified value for the BLER shown in Table 10.3.1.1-2.
Table 10.3.1.1-1: Test Parameters for Testing
Parameter |
Unit |
Test 1-2 |
|
Downlink power allocation |
dB |
0 |
|
dB |
0 (Note 1) |
||
σ |
dB |
0 |
|
at antenna port |
dBm/15kHz |
-98 |
|
PDSCH transmission mode in PCell and SCell |
1 |
||
Subcarrier spacing for SCell |
kHz |
1.25 kHz |
|
Allocated subframes per Radio Frame for SCell (Note 2) |
8 subframes |
||
Number of OFDM symbols for PDCCH for SCell |
0 (MBSFN subframes) 2 (non-MBSFN subframes) |
||
Cyclic Prefix for Scell in non-MBSFN subframes |
Extended |
||
Note 1: . Note 2: For SCell with FDD mode, up to 8 subframes (#1/2/3/4/6/7/8/9) are available for MBMS, in line with TS 36.331. |
Table 10.3.1.1-2: Minimum performance
Test number |
Cell |
Bandwidth (MHz) |
Reference Channel |
OCNG Pattern |
Propagation condition |
Correlation Matrix and antenna |
Reference value |
MBMS UE Category |
|
BLER (%) |
SNR(dB) |
||||||||
1 |
PCell |
10 |
NA |
OP.1 FDD |
AWGN |
1×2 low |
NA |
NA |
NA |
SCell |
10 |
R.81-1 FDD |
OP.4A FDD |
MBSFN channel model (Table B.2.6.2-1) |
1×2 low |
1 |
14.1 |
≥2 |
|
2 |
PCell |
10 |
NA |
OP.1 FDD |
AWGN |
1×2 low |
NA |
NA |
NA |
SCell |
10 |
R.81-2 FDD |
OP.4A FDD |
MBSFN channel model (Table B.2.6.2-1) |
1×2 low |
1 |
26.0 |
≥2 |
10.3.1.2 Minimum requirement with 7.5kHz subcarrier spacing
The receive characteristic of MBMS is determined by the BLER. The requirement is valid for all RRC states for which the UE has capabilities for FeMBMS Unicast-mixed Cell under CA.
For the parameters specified in Table 10.3.1.2-1 and Annex A.3.8.1, the average downlink SNR shall be below the specified value for the BLER shown in Table 10.3.1.2-2.
Table 10.3.1.2-1: Test Parameters for Testing
Parameter |
Unit |
Test 1 |
|
Downlink power allocation |
dB |
0 |
|
dB |
0 (Note 1) |
||
σ |
dB |
0 |
|
at antenna port |
dBm/15kHz |
-98 |
|
PDSCH transmission mode in PCell and SCell |
1 |
||
Subcarrier spacing for SCell |
kHz |
7.5 kHz |
|
Allocated subframes per Radio Frame for SCell (Note 2) |
8 subframes |
||
Number of OFDM symbols for PDCCH for SCell |
0 (MBSFN subframes) 2 (non-MBSFN subframes) |
||
Cyclic Prefix for Scell in non-MBSFN subframes |
Extended |
||
Note 1: . Note 2: For SCell with FDD mode, up to 8 subframes (#1/2/3/4/6/7/8/9) are available for MBMS, in line with TS 36.331. |
Table 10.3.1.2-2: Minimum performance
Test number |
Cell |
Bandwidth (MHz) |
Reference Channel |
OCNG Pattern |
Propagation condition |
Correlation Matrix and antenna |
Reference value |
MBMS UE Category |
|
BLER (%) |
SNR(dB) |
||||||||
1 |
PCell |
10 |
NA |
OP.1 FDD |
AWGN |
1×2 low |
NA |
NA |
NA |
SCell |
10 |
R.82-1 FDD |
OP.4A FDD |
MBSFN channel model (Table B.2.6.1-1) |
1×2 low |
1 |
13.9 |
≥2 |
10.3.2 Minimum requirement for FeMBMS Unicast-mixed Cell as Non-Serving Cell
10.3.2.1 Minimum requirement with 1.25kHz subcarrier spacing
The receive characteristic of MBMS is determined by the BLER. The requirement is valid for all RRC states for which the UE has capabilities for FeMBMS Unicast-mixed Cell as non-serving cell.
For the parameters specified in Table 10.3.2.1-1 and Annex A.3.8.1, the average downlink SNR shall be below the specified value for the BLER shown in Table 10.3.2.1-2.
Table 10.3.2.1-1: Test Parameters for Testing
Parameter |
Unit |
Test 1-4 |
|
Downlink power allocation |
dB |
0 |
|
dB |
0 (Note 1) |
||
σ |
dB |
0 |
|
at antenna port |
dBm/15kHz |
-98 |
|
Subcarrier spacing |
kHz |
1.25 kHz |
|
Allocated subframes per Radio Frame (Note 2) |
8 subframes |
||
Number of OFDM symbols for PDCCH |
0 (MBSFN subframes) 2 (non-MBSFN subframes) |
||
Cyclic Prefix in non-MBSFN subframes |
Extended |
||
Note 1: . Note 2: For FDD mode, up to 8 subframes (#1/2/3/4/6/7/8/9) are available for MBMS, in line with TS 36.331. |
Table 10.3.2.1-2: Minimum performance
Test number |
Cell |
Bandwidth (MHz) |
Reference Channel |
OCNG Pattern |
Propagation condition |
Correlation Matrix and antenna |
Reference value |
MBMS UE Category |
|
BLER (%) |
SNR(dB) |
||||||||
1 |
PCell |
10 |
NA |
OP.1 FDD |
AWGN |
1×2 low |
NA |
NA |
NA |
FeMBMS Unicast-mixed Cell as non-serving cell |
10 |
R.81-1 FDD |
OP.4A FDD |
MBSFN channel model (Table B.2.6.2-1) |
1×2 low |
1 |
14.1 |
≥2 |
|
2 |
PCell |
10 |
NA |
OP.1 FDD |
AWGN |
1×2 low |
NA |
NA |
NA |
FeMBMS Unicast-mixed Cell as non-serving cell |
10 |
R.81-2 FDD |
OP.4A FDD |
MBSFN channel model (Table B.2.6.2-1) |
1×2 low |
1 |
26.0 |
≥2 |
10.3.2.2 Minimum requirement with 7.5kHz subcarrier spacing
The receive characteristic of MBMS is determined by the BLER. The requirement is valid for all RRC states for which the UE has capabilities for enhanced FeMBMS Unicast-mixed Cell as non-serving cell.
For the parameters specified in Table 10.3.2.2-1 and Annex A.3.8.1, the average downlink SNR shall be below the specified value for the BLER shown in Table 10.3.2.2-2.
Table 10.3.2.2-1: Test Parameters for Testing
Parameter |
Unit |
Test 1-4 |
|
Downlink power allocation |
dB |
0 |
|
dB |
0 (Note 1) |
||
σ |
dB |
0 |
|
at antenna port |
dBm/15kHz |
-98 |
|
Subcarrier spacing |
kHz |
7.5 kHz |
|
Allocated subframes per Radio Frame (Note 2) |
8 subframes |
||
Number of OFDM symbols for PDCCH |
0 (MBSFN subframes) 2 (non-MBSFN subframes) |
||
Cyclic Prefix in non-MBSFN subframes |
Extended |
||
Note 1: . Note 2: For FDD mode, up to 8 subframes (#1/2/3/4/6/7/8/9) are available for MBMS, in line with TS 36.331. |
Table 10.3.2.2-2: Minimum performance
Test number |
Cell |
Bandwidth (MHz) |
Reference Channel |
OCNG Pattern |
Propagation condition |
Correlation Matrix and antenna |
Reference value |
MBMS UE Category |
|
BLER (%) |
SNR(dB) |
||||||||
1 |
PCell |
10 |
NA |
OP.1 FDD |
AWGN |
1×2 low |
NA |
NA |
NA |
FeMBMS Unicast-mixed Cell as non-serving cell |
10 |
R.82-1 FDD |
OP.4A FDD |
MBSFN channel model (Table B.2.6.1-1) |
1×2 low |
1 |
13.9 |
≥2 |
10.3.3 Minimum requirement for MBMS Dedicated cell
10.3.3.1 Minimum requirement with 1.25kHz subcarrier spacing
The receive characteristic of MBMS is determined by the BLER. The requirement is valid for all RRC states for which the UE has capabilities for MBMS Dedicated Cell.
For the parameters specified in Table 10.3.3.1-1 and Annex A.3.8.1, the average downlink SNR shall be below the specified value for the BLER shown in Table 10.3.3.1-2.
Table 10.3.3.1-1: Test Parameters for Testing MBMS Dedicated Cell
Parameter |
Unit |
Test 1-2 |
|
Downlink power allocation |
dB |
0 |
|
dB |
0 (Note 1) |
||
σ |
dB |
0 |
|
at antenna port |
dBm/1.25kHz |
-98 |
|
PDSCH transmission mode in PCell |
1 |
||
Subcarrier spacing for MBMS Dedicated Cell |
kHz |
1.25 kHz |
|
Allocated subframes per Radio Frame for MBMS Dedicated Cell (Note 2) |
10 subframes |
||
Number of OFDM symbols for PDCCH for MBMS Dedicated Cell |
0 (MBSFN subframes) 2 (non-MBSFN subframes) |
||
Cyclic Prefix for CAS in MBMS Dedicated Cell |
Extended |
||
Note 1: . Note 2: All subframes are MBSFN subframes except CAS |
Table 10.3.3.1-2: Minimum performance for MBMS dedicated Cell
Test number |
Cell |
Bandwidth (MHz) |
Reference Channel |
OCNG Pattern |
Propagation condition |
Correlation Matrix and antenna |
Reference value |
MBMS UE Category |
|
BLER (%) |
SNR(dB) |
||||||||
1 |
PCell |
10 |
NA |
OP.1 FDD |
AWGN |
1×2 low |
NA |
NA |
NA |
MBMS Dedicated Cell |
10 |
R.83-1 FDD |
NA |
MBSFN channel model (Table B.2.6.2-1) |
1×2 low |
1 |
14.1 |
≥2 |
|
2 |
PCell |
10 |
NA |
OP.1 FDD |
AWGN |
1×2 low |
NA |
NA |
NA |
MBMS Dedicated Cell |
10 |
R.83-2 FDD |
NA |
MBSFN channel model (Table B.2.6.2-1) |
1×2 low |
1 |
26.0 |
≥2 |
10.3.3.2 Minimum requirement with 7.5kHz subcarrier spacing
The receive characteristic of MBMS is determined by the BLER. The requirement is valid for all RRC states for which the UE has capabilities for MBMS Dedicated Cell.
For the parameters specified in Table 10.3.3.2-1 and Annex A.3.8.1, the average downlink SNR shall be below the specified value for the BLER shown in Table 10.3.3.2-2.
Table 10.3.3.2-1: Test Parameters for Testing MBMS Dedicated Cell
Parameter |
Unit |
Test 1 |
|
Downlink power allocation |
dB |
0 |
|
dB |
0 (Note 1) |
||
σ |
dB |
0 |
|
at antenna port |
dBm/1.25kHz |
-98 |
|
PDSCH transmission mode in PCell |
1 |
||
Subcarrier spacing for MBMS Dedicated Cell |
kHz |
7.5 kHz |
|
Allocated subframes per Radio Frame for MBMS Dedicated Cell (Note 2) |
10 subframes |
||
Number of OFDM symbols for PDCCH for MBMS Dedicated Cell |
0 (MBSFN subframes) 2 (non-MBSFN subframes) |
||
Cyclic Prefix for CAS in MBMS Dedicated Cell |
Extended |
||
Note 1: . Note 2: All subframes are MBSFN subframes except CAS |
Table 10.3.3.2-2: Minimum performance for MBMS dedicated Cell
Test number |
Cell |
Bandwidth (MHz) |
Reference Channel |
OCNG Pattern |
Propagation condition |
Correlation Matrix and antenna |
Reference value |
MBMS UE Category |
|
BLER (%) |
SNR(dB) |
||||||||
1 |
PCell |
10 |
NA |
OP.1 FDD |
AWGN |
1×2 low |
NA |
NA |
NA |
MBMS Dedicated Cell |
10 |
R.84-1 FDD |
NA |
MBSFN channel model (Table B.2.6.1-1) |
1×2 low |
1 |
13.9 |
≥2 |
10.3.3.3 Minimum requirement with 15kHz subcarrier spacing
The receive characteristic of MBMS is determined by the BLER. The requirement is valid for all RRC states for which the UE has capabilities for MBMS Dedicated Cell.
For the parameters specified in Table 10.3.3.3-1 and Annex A.3.8.1, the average downlink SNR shall be below the specified value for the BLER shown in Table 10.3.3.3-2.
Table 10.3.3.3-1: Test Parameters for Testing MBMS Dedicated Cell
Parameter |
Unit |
Test 1-3 |
|
Downlink power allocation |
dB |
0 |
|
dB |
0 (Note 1) |
||
σ |
dB |
0 |
|
at antenna port |
dBm/1.25kHz |
-98 |
|
PDSCH transmission mode in PCell |
1 |
||
Subcarrier spacing for MBMS Dedicated Cell |
kHz |
15 kHz |
|
Allocated subframes per Radio Frame for MBMS Dedicated Cell (Note 2) |
10 subframes |
||
Number of OFDM symbols for PDCCH for MBMS Dedicated Cell |
0 (MBSFN subframes) 2 (non-MBSFN subframes) |
||
Cyclic Prefix for MBMS Dedicated Cell |
Extended |
||
Note 1: . Note 2: All subframes are MBSFN subframes |
Table 10.3.3.3-2: Minimum performance for MBMS dedicated Cell
Test number |
Cell |
Bandwidth (MHz) |
Reference Channel |
OCNG Pattern |
Propagation condition |
Correlation Matrix and antenna |
Reference value |
MBMS UE Category |
|
BLER (%) |
SNR(dB) |
||||||||
1 |
PCell |
10 |
NA |
OP.1 FDD |
AWGN |
1×2 low |
NA |
NA |
NA |
MBMS Dedicated Cell |
3 |
R.85-1 FDD |
NA |
MBSFN channel model (Table B.2.6.1-1) |
1×2 low |
1 |
7.0 |
≥2 |
|
2 |
PCell |
10 |
NA |
OP.1 FDD |
AWGN |
1×2 low |
NA |
NA |
NA |
MBMS Dedicated Cell |
5 |
R.85-2 FDD |
NA |
MBSFN channel model (Table B.2.6.1-1) |
1×2 low |
1 |
13.5 |
≥2 |
|
3 |
PCell |
10 |
NA |
OP.1 FDD |
AWGN |
1×2 low |
NA |
NA |
NA |
MBMS Dedicated Cell |
10 |
R.85-3 FDD |
NA |
MBSFN channel model (Table B.2.6.1-1) |
1×2 low |
1 |
22.3 |
≥2 |
10.4 FDD with 5G terrestrial broadcast
For all tests in section 10.4 the applicability rules are defined in Table 10.4-1 depending on the capabilities of the UE. The requirements in clause 10.4 are applicable to UEs that support 5G terrestrial broadcast.
Table 10.4-1: 5G terrestrial broadcast tests applicability
Tests |
Applicable if UE supports at least the following capability |
Table 10.4.1.1-2 test 1 |
5G terrestrial broadcast support of mbms-ScalingFactor0dot37-r16 and timeSeparationSlot4-r16 |
Table 10.4.1.1-2 test 2 |
5G terrestrial broadcast support of mbms-ScalingFactor0dot37-r16 and timeSeparationSlot2-r16 |
Table 10.4.1.2-2 test 1 |
5G terrestrial broadcast support of mbms-ScalingFactor2dot5-r16 |
Table 10.4.2.1-1 test 1 |
5G terrestrial broadcast support of mbms-ScalingFactor0dot37-r16 and 5G terrestrial broadcast support of PBCH repetition in CAS |
Table 10.4.2.1-1 test 2 |
5G terrestrial broadcast support of mbms-ScalingFactor2dot5-r16 and 5G terrestrial broadcast support of PBCH repetition in CAS |
For the requirements defined in this section, the difference between CRS EPRE and the MBSFN RS EPRE should be set to 16dB for subcarrier spacing as 0.37kHz, 7.8 dB for subcarrier spacing as 2.5kHz because the UE demodulation performance might be different when this condition is not met (e.g. in scenarios where power offsets are present, such as scenarios when reserved cells are present).
10.4.1 Minimum requirement for PMCH decoding
10.4.1.1 Minimum requirement with 0.37kHz subcarrier spacing
The receive characteristic of MBMS is determined by the BLER.
For the parameters specified in Table 10.4.1.1-1 and Table A.3.8.1-9, the average downlink SNR shall be below the specified value for the BLER shown in Table 10.4.1.1-2.
Table 10.4.1.1-1: Test Parameters for Testing
Parameter |
Unit |
||
Downlink power allocation |
dB |
0 |
|
dB |
0 (Note 1) |
||
σ |
dB |
0 |
|
at antenna port |
dBm/15kHz |
-98 |
|
PDSCH transmission mode in PCell |
1 |
||
Subcarrier spacing for MBSFN cell |
kHz |
0.37 kHz |
|
Bandwidth |
MHz |
10(Note 2) |
|
Note 1: = 0. Note 2: For both Pcell and Scell. |
Table 10.4.1.1-2: Minimum performance
Test number |
Cell |
Bandwidth (MHz) |
Reference Channel |
MBSFN RS type |
OCNG Pattern |
Propagation condition |
Correlation Matrix and antenna |
Reference value |
MBMS UE Category |
|
BLER (%) |
SNR(dB) |
|||||||||
1 |
PCell |
10 |
N/A |
N/A |
OP.1 FDD |
AWGN |
1×1 |
N/A |
N/A |
N/A |
MBMS Dedicated Cell |
10 |
R.106-1 FDD |
Type 1 |
N/A |
MBSFN channel model (Table B.2.6.3-1) |
1×1 |
1 |
18.5 |
≥ 2 |
|
2 |
PCell |
10 |
N/A |
N/A |
OP.1 FDD |
AWGN |
1×1 |
N/A |
N/A |
N/A |
MBMS Dedicated Cell |
10 |
R.106-2 FDD |
Type 2 |
N/A |
MBSFN channel model (Table B.2.6.3-1) |
1×1 |
1 |
20.2 |
≥ 2 |
10.4.1.2 Minimum requirement with 2.5kHz subcarrier spacing
The receive characteristic of MBMS is determined by the BLER.
For the parameters specified in Table 10.4.1.2-1 and Table A.3.8.1-10, the average downlink SNR shall be below the specified value for the BLER shown in Table 10.4.1.2-2.
Table 10.4.1.2-1: Test Parameters for Testing
Parameter |
Unit |
||
Downlink power allocation |
dB |
0 |
|
dB |
0 (Note 1) |
||
σ |
dB |
0 |
|
at antenna port |
dBm/15kHz |
at antenna port |
|
PDSCH transmission mode in PCell |
1 |
||
Subcarrier spacing for MBSFN cell |
kHz |
2.5 kHz |
|
Bandwidth |
MHz |
10(Note 2) |
|
Note 1: = 0. Note 2: For both Pcell and Scell. |
Table 10.4.1.2-2: Minimum performance
Test number |
Cell |
Bandwidth (MHz) |
Reference Channel |
OCNG Pattern |
Propagation condition |
Correlation Matrix and antenna |
Reference value |
MBMS UE Category |
|
BLER (%) |
SNR(dB) |
||||||||
1 |
PCell |
10 |
N/A |
OP.1 FDD |
AWGN |
1×2 low |
N/A |
N/A |
N/A |
MBMS Dedicated Cell |
10 |
R.107 FDD |
N/A |
MBSFN channel model (Table B.2.6.4-1) |
1×2 low |
1 |
12.9 |
≥ 2 |
10.4.2 Minimum requirement for CAS detection
10.4.2.1 Minimum requirement for PBCH detection
For the parameters specified in Table 8.6.1-1, the average probability of a miss-detected PBCH (Pm-bch) shall be below the specified value in Table 10.4.2.1-1. The downlink physical setup is in accordance with Annex C.3.2.
Table 10.4.2.1-1: Minimum performance
Test number |
Cell |
Bandwidth (MHz) |
Reference Channel |
OCNG Pattern |
Propagation condition |
Correlation Matrix and antenna |
Reference value |
MBMS UE Category |
|
Pm-bch (%) |
SNR(dB) |
||||||||
1 |
PCell |
10 |
N/A |
OP.1 FDD |
AWGN |
1×1 low |
N/A |
N/A |
N/A |
MBMS Dedicated Cell |
10 |
R.23-1 |
N/A |
AWGN |
1×1 low |
1 |
-7.2 |
≥ 2 |
|
2 |
PCell |
10 |
N/A |
OP.1 FDD |
AWGN |
1×2 low |
N/A |
N/A |
N/A |
MBMS Dedicated Cell |
10 |
R.23-1 |
N/A |
EVA 162Hz |
1×2 low |
1 |
-6.7 |
≥ 2 |