8.2.45 Duration Measurement
29.2443GPPInterface between the Control Plane and the User Plane nodesRelease 17TS
The Duration Measurement IE type shall be encoded as shown in Figure 8.2.45-1. It contains the used time in seconds.
Bits |
||||||||||
Octets |
8 |
7 |
6 |
5 |
4 |
3 |
2 |
1 |
||
1 to 2 |
Type = 67 (decimal) |
|||||||||
3 to 4 |
Length = n |
|||||||||
5 to 8 |
Duration value |
|||||||||
9 to (n+4) |
These octet(s) is/are present only if explicitly specified |
Figure 8.2.45-1: Duration Measurement
The Duration value shall be encoded as an Unsigned32 binary integer value.