The Measurement Period IE contains the period, in seconds, for generating periodic usage reports or the periodic QoS monitoring reports. It shall be encoded as shown in Figure 8.2.42-1.

Bits

Octets

8

7

6

5

4

3

2

1

1 to 2

Type = 64 (decimal)

3 to 4

Length = n

5 to 8

Measurement Period

9 to (n+4)

These octet(s) is/are present only if explicitly specified

Figure 8.2.42-1: Measurement Period

The Measurement Period field shall be encoded as an Unsigned32 binary integer value.