8.2.28 Downlink Data Notification Delay
29.2443GPPInterface between the Control Plane and the User Plane nodesRelease 17TS
The Downlink Data Notification Delay IE indicates the delay the UP function shall apply between receiving a downlink data packet and notifying the CP function about the arrival of the packet. It is coded as depicted in Figure 8.2.28-1.
Bits |
||||||||||
Octets |
8 |
7 |
6 |
5 |
4 |
3 |
2 |
1 |
||
1 to 2 |
Type = 46 (decimal) |
|||||||||
3 to 4 |
Length = n |
|||||||||
5 |
Delay Value in integer multiples of 50 millisecs, or zero |
|||||||||
6 to (n+4) |
These octet(s) is/are present only if explicitly specified |
Figure 8.2.28-1: Downlink Data Notification Delay
Delay Value shall be set to zero in order to clear a previously set delay condition.