8.2.17 Subsequent Time Threshold

29.2443GPPInterface between the Control Plane and the User Plane nodesRelease 17TS

The Subsequent Time Threshold IE contains the subsequent traffic duration threshold to be monitored by the UP function after the Monitoring Time. It shall be encoded as shown in Figure 8.2.17-1.

Bits

Octets

8

7

6

5

4

3

2

1

1 to 2

Type = 35 (decimal)

3 to 4

Length = n

5 to 8

Subsequent Time Threshold

9 to (n+4)

These octet(s) is/are present only if explicitly specified

Figure 8.2.17-1: Subsequent Time Threshold

The Subsequent Time Threshold field shall be encoded as an Unsigned32 binary integer value. It shall contain the duration in seconds.