8.2.15 Monitoring Time
29.2443GPPInterface between the Control Plane and the User Plane nodesRelease 17TS
The Monitoring Time IE indicates the time at which the UP function is expected to reapply the thresholds. It shall be encoded as shown in Figure 8.2.15-1.
Bits |
||||||||||
Octets |
8 |
7 |
6 |
5 |
4 |
3 |
2 |
1 |
||
1 to 2 |
Type = 33 (decimal) |
|||||||||
3 to 4 |
Length = n |
|||||||||
5 to 8 |
Monitoring Time |
|||||||||
9 to (n+4) |
These octet(s) is/are present only if explicitly specified |
Figure 8.2.15-1: Monitoring Time
The Monitoring Time field shall indicate the monitoring time in UTC time. Octets 5 to 8 shall be encoded in the same format as the first four octets of the 64-bit timestamp format as defined in clause 6 of IETF RFC 5905 [12].
NOTE: The encoding is defined as the time in seconds relative to 00:00:00 on 1 January 1900.