8.2.145 Requested Clock Drift Information
29.2443GPPInterface between the Control Plane and the User Plane nodesRelease 17TS
The Requested Clock Drift Information IE shall be encoded as shown in Figure 8.2.145-1. It indicates the clock drift information to report to the CP function.
Bits |
|||||||||||
Octets |
8 |
7 |
6 |
5 |
4 |
3 |
2 |
1 |
|||
1 to 2 |
Type = 204 (decimal) |
||||||||||
3 to 4 |
Length = n |
||||||||||
5 |
Spare |
RRCR |
RRTO |
||||||||
7 to (n+4) |
These octet(s) is/are present only if explicitly specified |
Figure 8.2.145-1: Requested Clock Drift Information
Octet 5 shall be encoded as follows:
– Bit 1: (RRTO) Request to Report Time Offset: when set to "1", this indicates a request to report when the Time Offset Reporting Threshold is exceeded.
– Bit 2: (RRCR) Request to Report Cumulative RateRatio: when set to "1", this indicates a request to report when the cumulative RateRatio Reporting Thresholds is exceeded.
– Bits 3 to 8: Spare, for future use and set to "0".