8.5.71 Actions related to MULTIFLOW_STATUS variable (FDD only)
25.3313GPPProtocol specificationRadio Resource Control (RRC)Release 17TS
The variable MULTIFLOW_STATUS shall be set to TRUE only when all the following conditions are met:
1> the UE is in CELL_DCH state;
1> the variable HS_DSCH_RECEPTION is TRUE;
1> at least one of the entries in the variable SECONDARY_CELL_HS_DSCH_RECEPTION is TRUE;
1> the IE "Multiflow configuration" is present in all the entries in DOWNLINK_SECONDARY_CELL_INFO.
If any of the above conditions is not met and the variable MULTIFLOW_STATUS is set to TRUE, the UE shall:
1> set the variable MULTIFLOW_STATUS to FALSE.
Whenever the variable MULTIFLOW_STATUS is set to TRUE, the UE shall:
1> perform Multiflow data reception as specified in [51];
1> indicate to lower layers value of "Multiflow configuration" IE of each entry in DOWNLINK_SECONDARY_CELL_INFO;
1> if Multiflow configuration is four cells on three frequencies, then indicate to lower layers numbering of the first (assisting) and second (assisting) secondary serving HS-DSCH cells;
1> for every entry in DOWNLINK_SECONDARY_CELL_INFO:
2> if the stored UARFCN downlink (Nd) in the entry is the same as the value of the serving HS-DSCH cell:
3> if the IE "Multiflow time reference cell" is not present:
4> indicate to lower layers that the serving HS-DSCH cell is time reference for HS-DPCCH;
3> else:
4> indicate to lower layers that the cell is a time reference for HS-DPCCH;
2> else:
3> if the IE "Multiflow time reference cell" is present:
4> indicate to lower layers that the cell and the time reference cell are in the same cell group as specified in [27];
3> else:
4> indicate to lower layers that the cell and the non-time reference cell are in the same cell group as specified in [27];
1> If there is at least one entry in DOWNLINK_SECONDARY_CELL_INFO with the IE "Multiflow cell", value of which is set to "inter-NodeB":
2> configure two MAC-ehs entities;
2> associate with the first MAC-ehs entity the serving HS-DSCH cell and all the HS-DSCH cells, entries of which in DOWNLINK_SECONDARY_CELL_INFO have the IE "Multiflow cell" set to "intra-NodeB";
2> associate with the second MAC-ehs entity all the HS-DSCH cells, entries of which in DOWNLINK_SECONDARY_CELL_INFO have the IE "Multiflow cell" set to "inter-NodeB";
Whenever the variable MULTIFLOW_STATUS is set to FALSE, the UE shall:
1> stop Multiflow operation;
1> if Timer_Reordering was configured for the receiving RLC entity:
2> configure the receiving RLC entity not to use the corresponding function;
1> if two MAC-ehs entities were configured for the inter-Node B Multiflow operation:
2> configure one MAC-ehs entity;
1> indicate to lower layers that the serving HS-DSCH cell must be used as a time reference for HS-DPCCH.