8.5.64 UE INFORMATION
25.3313GPPProtocol specificationRadio Resource Control (RRC)Release 17TS
8.5.64.1 General
Figure 8.5.64.1-1: UE INFORMATION Procedure
The purpose of this procedure is to to request the UE to report information.
8.5.64.2 Initiation
The procedure is initiated when the UTRAN sends a UE INFORMATION REQUEST to the UE.
8.5.64.3 Reception of the UE INFORMATION REQUEST message by the UE
UE Shall:
1> if IE "Logged Measurements Report Request" is present:
2> if Registered PLMN is present in the IE "PLMN Identity List" stored in variable LOGGED_MEAS_REPORT_VARIABLE:
3> if an IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" in variable LOGGED_MEAS_REPORT_VARIABLE is present:
4> set IE "Logged Meas Report" in the UE INFORMATION RESPONSE as follows:
5> include the IE "Absolute Time Info" and set it to the value of the IE "Absolute Time Info" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace reference" and set it to the value of IE "Trace reference" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace recording session" and set it to the value of IE"Trace recording session" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "TCE Id" and set it to the value of IE "TCE Id" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" and set it to include, in the same order as logged, one or more entries from LOGGED_MEAS_REPORT_VARIABLE;
5> clear the logged measurement results included in the list of IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" from LOGGED_MEAS_REPORT_VARIABLE;
5> if the variable LOGGED_MEAS_REPORT_VARIABLE is not empty:
6> include IE "Logged Meas Available";
1> if IE "Logged ANR Report Request" is present:
2> if Registered PLMN is the same as one of the PLMNs in the IE "PLMN Identity" or IE "Equivalent PLMN Identity List" stored in variable LOG_ANR_REPORT_VARIABLE:
3> if IE "Logged ANR Report Info" in variable LOG_ANR_REPORT_VARIABLE is present:
4> set IEs "Logged ANR Report Info" in the UE INFORMATION RESPONSE as follows:
5> include the IEs "Logged ANR Report Info List" and set it to include entries from LOG_ANR_REPORT_VARIABLE;
5> clear the logged measurement results included in the list of IEs "Logged ANR Report Info List" from the LOG_ANR_REPORT_VARIABLE;
5> clear the variable LOG_ANR_CONFIG and stop timer T327.
1> if IE "Connection Establishment Failure Request" is present:
2> if Registered PLMN is the same as the PLMN in the IE "PLMN Identity" stored in variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE:
3> set IE "Connection Establishment Failure Report" in the UE INFORMATION RESPONSE as follows:
4> include the IE "Logged Connection Establishment Failure Info-FDD" or "Logged Connection Establishment Failure Info-TDD" and set it to include the entry from the variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE;
4> set the IE "Time Since Failure" to indicate the elapsed time starting from the Logging of the Connection establishment failure information that is stored in the variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE.
3> clear the variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE;
1> transmit a UE INFORMATION RESPONSE message on the uplink DCCH using AM RLC.
8.5.64.4 Reception of the UE INFORMATION RESPONSE message by the UTRAN
Upon receiving an UE INFORMATION RESPONSE message, UTRAN may:
1> if the message includes the IE “Logged Meas Available” send a further UE INFORMATION REQUEST