14.7 UE positioning measurements
25.3313GPPProtocol specificationRadio Resource Control (RRC)Release 17TS
14.7.1 UE positioning measurement quantities
The quantity to measure for UE positioning is dependent on the positioning method and the method type requested in the IE "UE positioning reporting quantity".
1 SFN-SFN observed time difference type 2, optional.
2 Rx-Tx time difference type 2, optional.
3 GPS timing of cell fames, optional.
The definition of other GPS measurements is not within the scope of this specification.
14.7.2 Void
14.7.3 UE positioning reporting events
In the IE "UE positioning reporting criteria" in the Measurement Control messages, the UTRAN notifies the UE of which events should trigger a measurement report. UE positioning reporting events that can trigger a report are given below. The content of the measurement report is dependant on the positioning method and method type requested in the IE "UE positioning reporting quantity" of the Measurement Control message and is described in detail in [18].
When one measurement identity corresponds to multiple positioning events with identical event identities, the UE behaviour is not defined.
14.7.3.1 Reporting Event 7a: The UE position changes more than an absolute threshold
This event is used for UE-based methods only.
When this event is ordered by UTRAN in a measurement control message, the UE shall:
1> if the UE changes its position compared to the last reported position by more than the threshold defined by the IE "Threshold position change"; or
1> if no position has been reported since the event was configured and the UE changes its position compared to the first position estimate obtained after the event was configured by more than the threshold defined by the IE "Threshold position change":
2> send a measurement report as specified in subclause 8.6.7.19.1b;
2> if the value of IE "Amount of Reporting" in variable MEASUREMENT_IDENTITY for this event is greater than zero:
3> decrease IE "Amount of Reporting" in variable MEASUREMENT_IDENTITY for this event by one.
2> if the value of IE "Amount of Reporting" in variable MEASUREMENT_IDENTITY for this event is equal to zero:
3> delete this event from the list of events in variable MEASUREMENT_IDENTITY.
1> if the UE is unable to evaluate the event because a position measurement is not available:
2> not send a report.
14.7.3.2 Reporting Event 7b: SFN-SFN measurement changes more than an absolute threshold
When this event is ordered by UTRAN in a measurement control message, the UE shall:
1> send a measurement report when the SFN-SFN time difference measurement type 2 of any measured cell changes more than the threshold defined by the IE "Threshold SFN-SFN change"; and
1> if UTRAN set IE "Method Type" in "UE positioning reporting quantity" in the MEASUREMENT CONTROL message to "UE-based":
2> act as specified in subclause 8.6.7.19.1b.
1> if UTRAN set IE "Method Type" in "UE positioning reporting quantity" in the MEASUREMENT CONTROL message to "UE-assisted":
2> act as specified in subclause 8.6.7.19.1a.
1> if UTRAN set IE "Method Type" in "UE positioning reporting quantity" in the MEASUREMENT CONTROL message to "UE-assisted preferred but UE-based allowed" or "UE-based preferred but UE-assisted allowed":
2> the UE may choose to act according to either subclause 8.6.7.19.1a or 8.6.7.19.1b.
1> if the value of IE "Amount of Reporting" in variable MEASUREMENT_IDENTITY for this event is greater than zero:
2> decrease IE "Amount of Reporting" in variable MEASUREMENT_IDENTITY for this event by one.
1> if the value of IE "Amount of Reporting" in variable MEASUREMENT_IDENTITY for this event is equal to zero:
2> delete this event from the list of events in variable MEASUREMENT_IDENTITY.
14.7.3.3 Reporting Event 7c: GPS time and SFN time have drifted apart more than an absolute threshold
When this event is ordered by UTRAN in a measurement control message, the UE shall:
1> send a measurement report when the GPS Time Of Week and the SFN timer have drifted apart more than the threshold defined by the IE "Threshold SFN-GPS TOW"; and
1> if UTRAN set IE "Method Type" in "UE positioning reporting quantity" in the MEASUREMENT CONTROL message to "UE based":
2> act as specified in subclause 8.6.7.19.1b.
1> if UTRAN set IE "Method Type" in "UE positioning reporting quantity" in the MEASUREMENT CONTROL message to "UE assisted":
2> act as specified in subclause 8.6.7.19.1a.
1> if UTRAN set IE "Method Type" in "UE positioning reporting quantity" in the MEASUREMENT CONTROL message to "UE assisted preferred but UE based allowed" or "UE based preferred but UE assisted allowed":
2> act as specified in subclause 8.6.7.19.1a or in subclause 8.6.7.19.1b depending on the method type chosen by the UE.
1> if the value of IE "Amount of Reporting" in variable MEASUREMENT_IDENTITY for this event is greater than zero:
2> decrease IE "Amount of Reporting" in variable MEASUREMENT_IDENTITY for this event by one.
1> if the value of IE "Amount of Reporting" in variable MEASUREMENT_IDENTITY for this event is equal to zero:
2> delete this event from the list of events in variable MEASUREMENT_IDENTITY.
14.7.3.4 Reporting Event 7d: GANSS time and SFN time have drifted apart more than an absolute threshold
When this event is ordered by UTRAN in a measurement control message, the UE shall:
1> send a measurement report when the GANSS Time Of Week and the SFN timer have drifted apart more than the threshold defined by the IE "Threshold SFN-GANSS TOW"; and
1> if UTRAN set IE "Method Type" in "UE positioning reporting quantity" in the MEASUREMENT CONTROL message to "UE based":
2> act as specified in subclause 8.6.7.19.1b.
1> if UTRAN set IE "Method Type" in "UE positioning reporting quantity" in the MEASUREMENT CONTROL message to "UE assisted":
2> act as specified in subclause 8.6.7.19.1a.
1> if UTRAN set IE "Method Type" in "UE positioning reporting quantity" in the MEASUREMENT CONTROL message to "UE assisted preferred but UE based allowed" or "UE based preferred but UE assisted allowed":
2> act as specified in subclause 8.6.7.19.1a or in subclause 8.6.7.19.1b depending on the method type chosen by the UE.
1> if the value of IE "Amount of Reporting" in variable MEASUREMENT_IDENTITY for this event is greater than zero:
2> decrease IE "Amount of Reporting" in variable MEASUREMENT_IDENTITY for this event by one.
1> if the value of IE "Amount of Reporting" in variable MEASUREMENT_IDENTITY for this event is equal to zero:
2> delete this event from the list of events in variable MEASUREMENT_IDENTITY.