14.1.4 Event-triggered periodic intra-frequency measurement reports (informative)
25.3313GPPProtocol specificationRadio Resource Control (RRC)Release 17TS
14.1.4.1 Cell addition failure (FDD only)
Figure 14.1.4.1-1: Periodic reporting triggered by event 1A
When a cell enters the reporting range and triggers event 1A, the UE shall transmit a MEASUREMENT REPORT to the UTRAN and typically this may result in an update of the active set. However, in some situations the UTRAN may be unable to add a strong cell to corresponding the active set typically due to capacity shortage for example.
The UE shall continue reporting after the initial report by reverting to periodical measurement reporting if the reported cell is not added to the corresponding active set. This is illustrated in Figure 14.1.4.1-1. During periodic reporting the UE shall transmit MEASUREMENT REPORT messages to the UTRAN at predefined intervals. The reports shall include reporting information of the cells in the current active set and of the monitored cell(s) in the reporting range.
Event-triggered periodic measurement reporting shall be terminated if:
1> there are no longer any monitored cell(s) within the reporting range; or
1> the UTRAN has added cells to the corresponding active set so that it includes the maximum number of cells (defined by the reporting deactivation threshold parameter), which are allowed for event 1A to be triggered; or
1> the UE has sent the maximum number of MEASUREMENT REPORT messages (defined by the amount of reporting parameter).
The reporting period is assigned by the UTRAN (with the Reporting interval parameter). If the reporting interval is set to zero event-triggered periodic measurement reporting shall not be applied.
14.1.4.1a Cell removal failure (FDD only)
Figure 14.1.4.1a: Periodic reporting triggered by event 1B
When a cell enters the removal range and triggers event 1B, the UE shall transmit a MEASUREMENT REPORT to the UTRAN and typically this may result in the removal of the weakest active cell. If the UTRAN is unable to receive MEASUREMENT REPORT after the maximum retransmission, it is beneficial to receive continuous reports in this case as well.
The UE shall revert to periodical measurement reporting if the UTRAN does not update the corresponding active set after the transmission of the measurement report. This is illustrated in Figure 14.1.4.1a. During periodic reporting the UE shall transmit MEASUREMENT REPORT messages to the UTRAN at predefined intervals.
Event-triggered periodic measurement reporting shall be terminated if:
1> there are no longer any monitored cell(s) within the removal range; or
1> the UTRAN has removed cells from the corresponding active set so that there are no longer the minimum amount of active cells for event 1B to be triggered; or
1> the UE has sent the maximum number of MEASUREMENT REPORT messages (defined by the "amount of reporting" parameter).
The reporting period is assigned by the UTRAN (with the "Reporting interval" parameter). If the reporting interval is set to zero, event-triggered periodic measurement reporting shall not be applied.
14.1.4.2 Cell replacement failure (FDD only)
Figure 14.1.4.1-2: Periodic reporting triggered by event 1C
When a cell enters the replacement range and triggers event 1C, the UE shall transmit a MEASUREMENT REPORT to the UTRAN and typically this may result in the replacement of the weakest active cell. If the UTRAN is unable to replace the cell due to for example capacity shortage, it is beneficial to receive continuous reports in this case as well.
The UE shall revert to periodical measurement reporting if the UTRAN does not update the corresponding active set after the transmission of the measurement report. This is illustrated in Figure 14.1.4.1-2. During periodic reporting the UE shall transmit MEASUREMENT REPORT messages to the UTRAN at predefined intervals. The reports shall include reporting information of the cells in the current active set and of the monitored cell(s) in the replacement range.
Event-triggered periodic measurement reporting shall be terminated if:
1> there are no longer any monitored cell(s) within the replacement range; or
1> the UTRAN has removed cells from the corresponding active set so that there are no longer the minimum amount of active cells for event 1C to be triggered (as defined by the replacement activation threshold parameter); or
1> the UE has sent the maximum number of MEASUREMENT REPORT messages (defined by the amount of reporting parameter).
The reporting period is assigned by the UTRAN (with the Reporting interval parameter). If the reporting interval is set to zero, event-triggered periodic measurement reporting shall not be applied.