14.1.2 Intra-frequency reporting events for FDD
25.3313GPPProtocol specificationRadio Resource Control (RRC)Release 17TS
Within the measurement reporting criteria field in the Measurement Control message the UTRAN notifies the UE which events should trigger a measurement report. If present, the "reporting criteria for secondary UL frequency" notifies the UE which events should trigger a measurement report for the secondary uplink frequency. The listed events are the toolbox from which the UTRAN can choose the reporting events that are needed for the implemented handover evaluation function, or other radio network functions. If present, the IE "Cells to be excluded in detected set cells" notifies the UE to exclude cells from corresponding measurement report and UE shall exclude indicated cells from measurement report for intra-frequency measurement.
All the specified events are measured with respect to any of the measurement quantities given in subclause 14.1.1. The measurement quantities are measured on the monitored primary common pilot channels (CPICH) of the cell defined in the measurement object and measurement object on secondary UL frequency.
Special mechanisms for the events are illustrated in subclause 14.1.4 and 14.1.5.
NOTE: The events below are numbered 1A, 1B, 1C,… since all intra-frequency reporting events would be labelled 1X, inter-frequency reporting events would be labelled 2X, and so on for the other measurement types.
When one intra-frequency measurement identity corresponds to multiple intra-frequency events with identical event identities, the UE behaviour is not specified.
14.1.2.1 Reporting event 1A: A Primary CPICH enters the reporting range
When an intra-frequency measurement configuring event 1a is set up, the UE shall:
1> create a variable TRIGGERED_1A_EVENT per active set related to that measurement, which shall initially be empty;
1> delete the corresponding variable when the measurement is released.
When event 1A is configured in the UE, the UE shall:
1> if "Measurement quantity" is "pathloss" and Equation 1 below is fulfilled for one or more primary CPICHs, or if "Measurement quantity" is "CPICH Ec/N0" or "CPICH RSCP", and Equation 2 below is fulfilled for one or more primary CPICHs, for each of these primary CPICHs:
2> if all required reporting quantities are available for that cell; and
2> if the equations have been fulfilled for a time period indicated by "Time to trigger", and if that primary CPICH is part of cells allowed to trigger the event according to "Triggering condition 2", and if that primary CPICH is not included in the "cells triggered" in the corresponding variable TRIGGERED_1A_EVENT:
3> include that primary CPICH in the "cells recently triggered" in the corresponding variable TRIGGERED_1A_EVENT.
1> if the value of "Reporting deactivations threshold" for this event is greater than or equal to the current number of cells in the active set or equal to 0 and any primary CPICHs are stored in the "cells recently triggered" in the corresponding variable TRIGGERED_1A_EVENT:
2> if "Reporting interval" for this event is not equal to 0:
3> if the IE "Periodical reporting running" in the corresponding variable TRIGGERED_1A_EVENT is set to FALSE:
4> start a timer with the value of "Reporting interval" for this event and set the IE "Periodical reporting running" in the corresponding variable TRIGGERED_1A_EVENT to TRUE;
3> set "sent reports" for the primary CPICHs in "cells recently triggered" in the corresponding variable TRIGGERED_1A_EVENT to 1.
2> send a measurement report with IEs set as below:
3> set in "intra-frequency measurement event results" or in "cell measurement event results on secondary UL frequency": "Intrafrequency event identity" to "1a"; and
3> include in "cell measurement event results" or in "cell measurement event results on secondary UL frequency" all entries of the "cells recently triggered" in the corresponding variable TRIGGERED_1A_EVENT in descending order according to the configured measurement quantity taking into account the cell individual offset for each of those cells;
3> set the IE "measured results" and the IE "additional measured results", and/or the IE "measured results on secondary UL frequency" and the IE "additional measured results on secondary UL frequency" according to subclause 8.4.2, not taking into account the cell individual offset for each cell.
2> move all entries from "cells recently triggered" to "cells triggered" in the corresponding variable TRIGGERED_1A_EVENT.
1> if the timer for the corresponding periodical reporting has expired:
2> if any primary CPICH is included in the "cells triggered" in the corresponding variable TRIGGERED_1A_EVENT:
3> if "Reporting interval" for this event is not equal to 0, and if "Amount of reporting" is greater than "sent reports" stored for any of these primary CPICHs, in "cells triggered" in the corresponding variable TRIGGERED_1A_EVENT:
4> increment the stored counter "sent reports" for all CPICHs in "cell triggered" in the corresponding variable TRIGGERED_1A_EVENT;
4> start a timer with the value of "Reporting interval" for this event;
4> send a measurement report with IEs set as below:
5> set in "intra-frequency measurement event results" or in "cell measurement event results on secondary UL frequency": "Intrafrequency event identity" to "1a"; and
5> include in "cell measurement event results" or in "cell measurement event results on secondary UL frequency" all entries of the corresponding variable TRIGGERED_1A_EVENT with value of IE "sent reports" equal to or smaller than value of "Amount of reporting" in descending order according to the configured measurement quantity taking into account the cell individual offset for each of those cells;
5> set the IE "measured results" and the IE "additional measured results", and/or the IE "measured results on secondary UL frequency" and the IE "additional measured results on secondary UL frequency" according to subclause 8.4.2, not taking into account the cell individual offset for each cell.
4> if "sent reports" in the corresponding variable TRIGGERED_1A_EVENT is equal to "Amount of reporting" for all entries:
5> set the IE "Periodical Reporting running" in the corresponding variable TRIGGERED_1A_EVENT to FALSE and disable the timer for the corresponding periodical reporting.
1> if "Measurement quantity" is "pathloss" and Equation 3 below is fulfilled for a primary CPICH, or if "Measurement quantity" is "CPICH Ec/N0" or "CPICH RSCP", and Equation 4 below is fulfilled for a primary CPICH; or
1> if a primary CPICH is no longer part of the cells allowed to trigger the event according to the "Triggering condition 2":
2> if that primary CPICH is included in the "cells triggered" or "cells recently triggered" in the corresponding variable TRIGGERED_1A_EVENT:
3> remove the entry of that primary CPICH from "cells triggered" or "cells recently triggered" in the corresponding variable TRIGGERED_1A_EVENT.
3> if no entry in the corresponding variable TRIGGERED_1A_EVENT has a value of "sent reports" smaller than "Amount of reporting"; or
3> if there is no entry in the corresponding variable TRIGGERED_1A_EVENT:
4> if the corresponding reporting interval timer is running:
5> stop the reporting interval timer;
5> set the IE "Periodical reporting running" in the corresponding variable TRIGGERED_1A_EVENT to FALSE.
This event is only applicable to the CELL_DCH state. When the measurement is setup in CELL_DCH or upon transition to CELL_DCH the UE shall:
1> if the "Triggering condition 2" includes active set cells:
2> include the primary CPICH of all cells in the current active set into the "cells triggered" in the variable TRIGGERED_1A_EVENT with the counter "sent reports" set to "Amount of reporting".
Equation 1 (Triggering condition for pathloss)
Equation 2 (Triggering condition for all the other measurement quantities)
Equation 3 (Leaving triggering condition for pathloss)
Equation 4 (Leaving triggering condition for all the other measurement quantities)
The variables in the formula are defined as follows:
MNew is the measurement result of the cell entering the reporting range.
CIONew is the individual cell offset for the cell entering the reporting range if an individual cell offset is stored for that cell. Otherwise it is equal to 0.
Mi is a measurement result of a cell not forbidden to affect reporting range in the active set.
NA is the number of cells not forbidden to affect reporting range in the current active set.
For pathloss
MBest is the measurement result of the cell not forbidden to affect reporting range in the active set with the lowest measurement result, not taking into account any cell individual offset.
for other measurements quantities.
MBest is the measurement result of the cell not forbidden to affect reporting range in the active set with the highest measurement result, not taking into account any cell individual offset.
W is a parameter sent from UTRAN to UE.
R1a is the reporting range constant.
H1a is the hysteresis parameter for the event 1a.
If the measurement results are pathloss or CPICH-Ec/No then MNew, Mi and MBest are expressed as ratios.
If the measurement result is CPICH-RSCP then MNew, Mi and MBest are expressed in mW.
14.1.2.2 Reporting event 1B: A primary CPICH leaves the reporting range
When an intra-frequency measurement configuring event 1b is set up, the UE shall:
1> create a variable TRIGGERED_1B_EVENT per active set related to that measurement, which shall initially be empty;
1> delete the corresponding variable when the measurement is released.
When event 1B is configures in the UE, the UE shall:
1> if "Measurement quantity" is "pathloss" and Equation 1 below is fulfilled for one or more primary CPICHs, or if "Measurement quantity" is "CPICH Ec/N0" or "CPICH RSCP", and Equation 2 below is fulfilled for one or more primary CPICHs, for each of these primary CPICHs:
2> if all required reporting quantities are available for that cell, and if the equations have been fulfilled for a time period indicated by "Time to trigger", and if that primary CPICH is part of cells allowed to trigger the event according to "Triggering condition 1", and if that primary CPICH is not included in the "cells triggered" in the corresponding variable TRIGGERED_1B_EVENT:
3> include that primary CPICH in the "cells recently triggered" in the corresponding variable TRIGGERED_1B_EVENT.
1> if any primary CPICHs are stored in the "cells recently triggered" in the corresponding variable TRIGGERED_1B_EVENT:
2> if "Periodic reporting info-1b" is present, and "Reporting interval" for this event is not equal to 0:
3> if the IE "Periodical reporting running" in the corresponding variable TRIGGERED_1B_EVENT is set to FALSE:
4> start a timer with the value of "Reporting interval" for this event and set the IE "Periodical reporting running" in the corresponding variable TRIGGERED_1B_EVENT to TRUE;
3> set "sent reports" for the primary CPICHs in "cells recently triggered" in the corresponding variable TRIGGERED_1B_EVENT to 1.
2> send a measurement report with IEs set as below:
3> set in "intra-frequency measurement event results" or in "cell measurement event results on secondary UL frequency": "Intrafrequency event identity" to "1b"; and
3> include in "cell measurement event results" or in "cell measurement event results on secondary UL frequency" all entries of "cells recently triggered" in the corresponding variable TRIGGERED_1B_EVENT in ascending order according to the configured measurement quantity taking into account the cell individual offset for each of those cells;
3> set the IE "measured results" and the IE "additional measured results", and/or the IE "measured results on secondary UL frequency" and the IE "additional measured results on secondary UL frequency" according to subclause 8.4.2, not taking into account the cell individual offset for each cell.
2> move all entries from IE "cells recently triggered" to "cells triggered" in the corresponding variable TRIGGERED_1B_EVENT.
1> if the timer for the corresponding periodical reporting has expired:
2> if any primary CPICH is included in the "cells triggered" in the corresponding variable TRIGGERED_1B_EVENT:
3> if "Periodic reporting info-1b" is present:
4> if "Reporting interval" is not equal to 0, and if "Amount of reporting" is greater than "sent reports" stored for any of these primary CPICHs, in "cells triggered" in the corresponding variable TRIGGERED_1B_EVENT:
5> increment the stored counter "sent reports" for all CPICHs in "cell triggered" in the corresponding variable TRIGGERED_1B_EVENT;
5> start a timer with the value of "Reporting interval-1b" for this event;
5> send a measurement report with IEs set as below:
6> set in "intra-frequency measurement event results" or in "cell measurement event results on secondary UL frequency": "Intrafrequency event identity" to "1b"; and
6> include in "cell measurement event results" or in "measurement event results on secondary UL frequency" all entries of the corresponding variable TRIGGERED_1B_EVENT with value of IE "sent reports" equal to or smaller than value of "Amount of reporting" in ascending order according to the configured measurement quantity taking into account the cell individual offset for each of those cells;
6> set the IE "measured results" and the IE "additional measured results", and/or the IE "measured results on secondary UL frequency" and the IE "additional measured results on secondary UL frequency" according to subclause 8.4.2, not taking into account the cell individual offset for each cell.
5> if "sent reports" in the corresponding variable TRIGGERED_1B_EVENT is equal to "Amount of reporting" for all entries:
6> set the IE "Periodical Reporting running" in the corresponding variable TRIGGERED_1B_EVENT to FALSE and disable the timer for the corresponding periodical reporting.
1> if "Measurement quantity" is "pathloss" and Equation 3 below is fulfilled for a primary CPICH, or if "Measurement quantity" is "CPICH Ec/N0" or "CPICH RSCP", and Equation 4 below is fulfilled for a primary CPICH; or
1> if a primary CPICH is no longer part of the cells allowed to trigger the event according to the "Triggering condition 1":
2> if that primary CPICH is included in the "cells triggered" in the corresponding variable TRIGGERED_1B_EVENT:
3> remove the entry of that primary CPICH from "cells triggered" in the corresponding variable TRIGGERED_1B_EVENT;
3> if there is no entry in the corresponding variable TRIGGERED_1B_EVENT:
4> if the corresponding reporting interval timer is running:
5> stop the reporting interval timer;
5> set the IE "Periodical reporting running" in the corresponding variable TRIGGERED_1B_EVENT to FALSE.
Equation 1 (Triggering condition for pathloss)
Equation 2 (Triggering condition for all the other measurement quantities)
Equation 3 (Leaving triggering condition for pathloss)
Equation 4 (Leaving triggering condition for all the other measurement quantities)
The variables in the formula are defined as follows:
MOld is the measurement result of the cell leaving the reporting range.
CIOOld is the individual cell offset for the cell leaving the reporting range if an individual cell offset is stored for that cell. Otherwise it is equal to 0.
Mi is a measurement result of a cell not forbidden to affect reporting range in the active set.
NA is the number of cells not forbidden to affect reporting range in the current active set.
For pathloss
MBest is the measurement result of the cell not forbidden to affect reporting range in the active set with the lowest measurement result, not taking into account any cell individual offset.
for other measurements quantities.
MBest is the measurement result of the cell not forbidden to affect reporting range in the active set with the highest measurement result, not taking into account any cell individual offset.
W is a parameter sent from UTRAN to UE.
R1b is the reporting range constant.
H1b is the hysteresis parameter for the event 1b.
If the measurement results are pathloss or CPICH-Ec/No then MOld, Mi and MBest are expressed as ratios.
If the measurement result is CPICH-RSCP then MOld, Mi and MBest are expressed in mW.
14.1.2.3 Reporting event 1C: A non-active primary CPICH becomes better than an active primary CPICH
When an intra-frequency measurement configuring event 1c is set up, the UE shall:
1> create a variable TRIGGERED_1C_EVENT per active set related to that measurement, which shall initially be empty;
1> delete the corresponding variable when the measurement is released.
When event 1C is configured in the UE, the UE shall:
1> if "Measurement quantity" is "pathloss" and Equation 1 below is fulfilled for one or more primary CPICHs, or if "Measurement quantity" is "CPICH Ec/N0" or "CPICH RSCP", and Equation 2 below is fulfilled for one or more primary CPICHs, for each of these primary CPICHs:
2> if all required reporting quantities are available for that cell; and
2> if the equations have been fulfilled for a time period indicated by "Time to trigger", and if the primary CPICH that is better is not included in the active set but the other primary CPICH is any of the primary CPICHs included in the active set, and if that first primary CPICH is not included in the "cells triggered" in the corresponding variable TRIGGERED_1C_EVENT:
3> include that primary CPICH in the "cells recently triggered" in the corresponding variable TRIGGERED_1C_EVENT.
1> if the value of "Replacement activation threshold" for this event is less than or equal to the current number of cells in the active set or equal to 0 and if any primary CPICHs are stored in the "cells recently triggered" in the corresponding variable TRIGGERED_1C_EVENT:
2> if "Reporting interval" for this event is not equal to 0:
3> if the IE "Periodical reporting running" in the corresponding variable TRIGGERED_1C_EVENT is set to FALSE:
4> start a timer for with the value of "Reporting interval" for this event and set the IE "Periodical reporting running" in the corresponding variable TRIGGERED_1C_EVENT to TRUE.
3> set "sent reports" for that primary CPICH in the corresponding variable TRIGGERED_1C_EVENT to 1.
2> send a measurement report with IEs set as below:
3> set in "intra-frequency measurement event results" or in "cell measurement event results on secondary UL frequency": "Intrafrequency event identity" to "1c"; and
3> include in "cell measurement event results" or in "cell measurement event results on secondary UL frequency" all entries of the "cells recently triggered" in the corresponding variable TRIGGERED_1C_EVENT not in the active set as well as the "primary CPICH info" of all the primary CPICHs in the active set for which the measured value is worse (i.e. greater for pathloss and less for the other measurement quantities) than the one of the entry in "cell recently triggered" that has the best measured value taking into account their cell individual offset. The "primary CPICH info" for those cells shall be ordered according to their measured value taking into account their cell individual offset, beginning with the best cell to the worst one;
3> set the IE "measured results" and the IE "additional measured results", and/or the IE "measured results on secondary UL frequency" and the IE "additional measured results on secondary UL frequency" according to subclause 8.4.2, not taking into account the cell individual offset for each cell.
2> move all entries from "cells recently triggered" to "cells triggered" in the corresponding variable TRIGGERED_1C_EVENT.
1> if the timer for the periodical reporting has expired:
2> if any primary CPICH is included in the "cells triggered" in the corresponding variable TRIGGERED_1C_EVENT, and not included in the current active set:
3> if "Reporting interval" for this event is not equal to 0, and if "Amount of reporting" is greater than "sent reports" stored for that primary CPICH, in "cells triggered" in the corresponding variable TRIGGERED_1C_EVENT:
4> increment the stored counter "sent reports" for all CPICH in "cell triggered" in the corresponding variable TRIGGERED_1C_EVENT;
4> start a timer with the value of "Reporting interval" for this event;
4> send a measurement report with IEs set as below:
5> set in "intra-frequency measurement event results" or in "cell measurement event results on secondary UL frequency": "Intrafrequency event identity" to "1c"; and
5> include in "cell measurement event results" or in "measurement event results on secondary UL frequency" all entries of the corresponding variable TRIGGERED_1C_EVENT with value of IE "sent report" equal to or smaller than value of "Amount of reporting" and that are not part of the active set as well as the "primary CPICH info" of all the primary CPICHs in the active set for which the measured value is worse (i.e. greater for pathloss and less for the other measurement quantities) than the one of the entry in "cell triggered" that has the best measured value, ordering the "primary CPICH info" according to their measured value beginning with the best cell to the worst one, taking into account the cell individual offset for each cell;
5> set the IE "measured results" and the IE "additional measured results", and/or the IE "measured results on secondary UL frequency" and the IE "additional measured results on secondary UL frequency" according to subclause 8.4.2, not taking into account the cell individual offset for each cell.
4> if "sent reports" in the corresponding variable TRIGGERED_1C_EVENT is equal to "Amount of reporting" for all entries:
5> set the IE "Periodical Reporting running" in the corresponding variable TRIGGERED_1C_EVENT to FALSE and disable the timer for the corresponding periodical reporting.
1> if "Measurement quantity" is "pathloss" and Equation 3 below is fulfilled for a primary CPICH, or if "Measurement quantity" is "CPICH Ec/N0" or "CPICH RSCP", and Equation 4 below is fulfilled for a primary CPICH or;
1> if a primary CPICH is added to the active set:
2> if that primary CPICH is included in the "cells triggered" or "cells recently triggered" in the corresponding variable TRIGGERED_1C_EVENT:
3> remove the entry of that primary CPICH from "cells triggered" or "cells recently triggered" in the variable TRIGGERED_1C_EVENT.
3> if no entry in the corresponding variable TRIGGERED_1C_EVENT has a value of "sent reports" smaller than "Amount of reporting" or
3> if there is no entry in the corresponding variable TRIGGERED_1C_EVENT:
4> if the corresponding reporting interval timer is running:
5> stop the reporting interval timer;
5> set the IE "Periodical reporting running" in the corresponding variable TRIGGERED_1C_EVENT to FALSE.
Equation 1 (Triggering condition for pathloss)
Equation 2 (Triggering condition for all the other measurement quantities)
Equation 3 (Leaving triggering condition for pathloss)
Equation 4 (Leaving triggering condition for all the other measurement quantities)
The variables in the formula are defined as follows:
MNew is the measurement result of the cell not included in the active set.
CIONew is the individual cell offset for the cell becoming better than the cell in the active set if an individual cell offset is stored for that cell. Otherwise it is equal to 0.
For pathloss:
MInAS is the measurement result of the cell in the active set with the highest measurement result.
For other measurement quantities:
MInAS is the measurement result of the cell in the active set with the lowest measurement result.
CIOInAS is the individual cell offset for the cell in the active set that is becoming worse than the new cell.
H1c is the hysteresis parameter for the event 1c.
If the measurement results are pathloss or CPICH-Ec/No then MNew and MinAS are expressed as ratios.
If the measurement result is CPICH-RSCP then MNew and MinAS are expressed in mW.
Figure 14.1.2.3-1 [Informative]: A primary CPICH that is not included in the active set becomes better than a primary CPICH that is in the active set
In this figure, the parameters hysteresis and time to trigger, as well as the cell individual offsets for all cells are equal to 0. In this example the cells belonging to primary CPICH 1 and 2 are in the active set, but the cells transmitting primary CPICH 3 and CPICH 4 are not (yet) in the active set.
The first measurement report is sent when primary CPICH 4 becomes better than primary CPICH 2. The "cell measurement event result" of the measurement report contains the information of primary CPICH 4 and CPICH 2.
Assuming that the active set has been updated after the first measurement report (active set is now primary CPICH 1 and primary CPICH 4), the second report is sent when primary CPICH 3 becomes better than primary CPICH 1. The "cell measurement event result" of the second measurement report contains the information of primary CPICH 3 and primary CPICH 1.
14.1.2.4 Reporting event 1D: Change of best cell
When an intra-frequency measurement configuring event 1d is set up, the UE shall:
1> create a variable BEST_CELL_1D_EVENT related to that measurement, which shall initially contain the best cell in the active set when the measurement is initiated;
1> delete this variable when the measurement is released.
1> As soon as the best cell in the active set has been evaluated by the UE (and stored in the BEST_CELL_1D_EVENT variable) and provided that there is more than one cell in the active set, trigger an immediate measurement report with IEs set as below:
2> set in "intra-frequency measurement event results"; "Intrafrequency event identity" to "1d" and "cell measurement event results" to the CPICH info of the primary CPICH stored in the BEST_CELL_1D_EVENT variable;
2> set the IE "measured results" and the IE "additional measured results", and the IE "measured results on secondary UL frequency" and the IE "additional measured results on secondary UL frequency" according to subclause 8.4.2
When event 1D is configured in the UE, the UE shall:
1> if IE "useCIO" is present and its value is TRUE, take into account the Cell Individual Offset for evaluation of the Equation 1 and 2, otherwise do not take it into account.
1> if "Measurement quantity" is "pathloss" and Equation 1 below is fulfilled for a primary CPICH that is not stored in "Best cell" in variable BEST_CELL_1D_EVENT, or if "Measurement quantity" is "CPICH Ec/N0" or "CPICH RSCP", and Equation 2 below is fulfilled for a primary CPICH that is not stored in "Best cell" in variable BEST_CELL_1D_EVENT:
NOTE: If the equations are simultaneously fulfilled for more than one primary CPICH, the UE should report only one event 1D, triggered by the best primary CPICH.
2> if all required reporting quantities are available for that cell, and if the equations have been fulfilled for a time period indicated by "Time to trigger" and if IE "Triggering condition 2" is absent or if it is present and that primary CPICH is part of cells allowed to trigger the event according to "Triggering condition 2":
3> set "best cell" in the variable BEST_CELL_1D_EVENT to that primary CPICH that triggered the event;
3> send a measurement report with IEs set as below:
4> set in "intra-frequency measurement event results"; "Intrafrequency event identity" to "1d" and "cell measurement event results" to the CPICH info of the primary CPICH that triggered the report.
4> set the IE "measured results" and the IE "additional measured results", and the IE "measured results on secondary UL frequency" and the IE "additional measured results on secondary UL frequency" according to subclause 8.4.2.
This event is only applicable to the CELL_DCH state. Upon transition to CELL_DCH the UE shall:
1> set "best cell" in the variable BEST_CELL_1D_EVENT to the best cell of the primary CPICHs included in the active set.
Equation 1 (Triggering condition for pathloss)
Equation 2 (Triggering condition for all the other measurement quantities)
The variables in the formula are defined as follows:
MNotBest is the measurement result of a cell not stored in "best cell" in the variable BEST_CELL_1D_EVENT.
CIONotBest is the cell individual offset of a cell not stored in "best cell" in the variable BEST_CELL_1D_EVENT.
MBest is the measurement result of the cell stored in "best cell" in variable BEST_CELL_1D_EVENT.
CIOBest is the cell individual offset of a cell stored in "best cell" in the variable BEST_CELL_1D_EVENT.
H1d is the hysteresis parameter for the event 1d.
If the measurement results are pathloss or CPICH-Ec/No then MNot Best and MBest are expressed as ratios.
If the measurement result is CPICH-RSCP then MNot Best and MBest are expressed in mW.
Figure 14.1.2.4-1 [Informative]: A primary CPICH becomes better than the previously best primary CPICH
In this figure, the parameters hysteresis and time to trigger, as well as the cell individual offsets for all cells are equal to 0.
14.1.2.5 Reporting event 1E: A Primary CPICH becomes better than an absolute threshold
When an intra-frequency measurement configuring event 1e is set up, the UE shall:
1> create a variable TRIGGERED_1E_EVENT per active set related to that measurement, which shall initially be empty;
1> delete the corresponding variable when the measurement is released.
When event 1E is configured in the UE, the UE shall:
1> if "Measurement quantity" is "pathloss" and Equation 1 below is fulfilled for a primary CPICH, or if "Measurement quantity" is "CPICH Ec/N0" or "CPICH RSCP", and Equation 2 below is fulfilled for one or more primary CPICHs, for each of these primary CPICHs:
2> if all required reporting quantities are available for that cell, and if the equations have been fulfilled for a time period indicated by "Time to trigger", and if that primary CPICH is part of cells allowed to trigger the event according to "Triggering condition 2", and that primary CPICH is not included in the "cells triggered" in the corresponding variable TRIGGERED_1E_EVENT:
3> include that primary CPICH in the "cells recently triggered" in the corresponding variable TRIGGERED_1E_EVENT.
1> if any primary CPICHs are stored in the "cells recently triggered" in the corresponding variable TRIGGERED_1E_EVENT:
2> send a measurement report with IEs set as below:
3> set in "intra-frequency measurement event results" or in "cell measurement event results on secondary UL frequency": "Intrafrequency event identity" to "1e"; and
3> include in "cell measurement event results" or in "cell measurement event results on secondary UL frequency" all entries of the "cells recently triggered" in the corresponding variable TRIGGERED_1E_EVENT in descending order according to the configured measurement quantity taking into account the cell individual offset for each of those cells;
3> set the IE "measured results" and the IE "additional measured results", and/or the IE "measured results on secondary UL frequency" and the IE "additional measured results on secondary UL frequency" according to subclause 8.4.2, not taking into account the cell individual offset for each cell.
2> move all entries from "cells recently triggered" to "cells triggered" in the corresponding variable TRIGGERED_1E_EVENT.
1> if "Measurement quantity" is "pathloss" and Equation 3 below is fulfilled for a primary CPICH, or if "Measurement quantity" is "CPICH Ec/N0" or "CPICH RSCP", and Equation 4 below is fulfilled for a primary CPICH; or
1> if a primary CPICH is no longer part of the cells allowed to trigger the event according to the "Triggering condition 2":
2> if that primary CPICH is included in the "cells triggered" in the corresponding variable TRIGGERED_1E_EVENT:
3> remove that primary CPICH and sent reports from "cells triggered" in the corresponding variable TRIGGERED_1E_EVENT.
This event is only applicable to the CELL_DCH state. When the measurement is setup in CELL_DCH or upon transition to CELL_DCH the UE shall:
1> if the "Triggering condition 2" includes active set cells:
2> include the primary CPICH of all cells in the current active set that fulfil the equations 1 or 2 according to the "Measurement quantity" of event 1e into the "cells triggered" in the corresponding variable TRIGGERED_1E_EVENT.
Equation 1 (Triggering condition for pathloss)
Equation 2 (Triggering condition for all the other measurement quantities)
Equation 3 (Leaving triggering condition for pathloss)
Equation 4 (Leaving triggering condition for all the other measurement quantities)
The variables in the formula are defined as follows:
MNew is the measurement result of a cell that becomes better than an absolute threshold.
CIONew is the individual cell offset for the cell becoming better than the absolute threshold. Otherwise it is equal to 0.
T1e is an absolute threshold.
H1e is the hysteresis parameter for the event 1e.
If the measurement results are pathloss or CPICH-Ec/No then MNew is expressed as ratios.
If the measurement result is CPICH-RSCP then MNew is expressed in mW.
Figure 14.1.2.5-1 [Informative]: Event-triggered report when a Primary CPICH becomes better than an absolute threshold
In this figure, the parameters hysteresis and time to trigger, as well as the cell individual offsets for all cells are equal to 0.
14.1.2.6 Reporting event 1F: A Primary CPICH becomes worse than an absolute threshold
When an intra-frequency measurement configuring event 1F is set up, the UE shall:
1> create a variable TRIGGERED_1F_EVENT per active set related to that measurement, which shall initially be empty;
1> delete the corresponding variable when the measurement is released.
When event 1F is configured in the UE, the UE shall:
1> if "Measurement quantity" is "pathloss" and Equation 1 below is fulfilled for one or more primary CPICHs, or if "Measurement quantity" is "CPICH Ec/N0" or "CPICH RSCP", and Equation 2 below is fulfilled for one or more primary CPICHs, for each of these primary CPICHs:
2> if all required reporting quantities are available for that cell, and if the equations have been fulfilled for a time period indicated by "Time to trigger", and if that primary CPICH is part of cells allowed to trigger the event according to "Triggering condition 1", and that primary CPICH is not included in the "cells triggered" in the corresponding variable TRIGGERED_1F_EVENT:
3> include that primary CPICH in the "cells recently triggered" in the corresponding variable TRIGGERED_1F_EVENT.
1> if any primary CPICHs are stored in the "cells recently triggered" in the corresponding variable TRIGGERED_1F_EVENT:
2> send a measurement report with IEs set as below:
3> set in "intra-frequency event measurement results" or in "cell measurement event results on secondary UL frequency": "Intrafrequency event identity" to "1f"; and
3> include in "cell measurement event results" or in "cell measurement event results on secondary UL frequency" all entries of the "cells recently triggered" in the corresponding variable TRIGGERED_1F_EVENT in descending order according to the configured measurement quantity taking into account the cell individual offset for each of those cells;
3> set the IE "measured results" and the IE "additional measured results", and/or the IE "measured results on secondary UL frequency" and the IE "additional measured results on secondary UL frequency" according to subclause 8.4.2, not taking into account the cell individual offset for each cell;
2> move all entries from "cells recently triggered" to "cells triggered" in the corresponding variable TRIGGERED_1F_EVENT.
1> if "Measurement quantity" is "pathloss" and Equation 3 below is fulfilled for a primary CPICH, or if "Measurement quantity" is "CPICH Ec/N0" or "CPICH RSCP", and Equation 4 below is fulfilled for a primary CPICH; or
1> if a primary CPICH is no longer part of the cells allowed to trigger the event according to the "Triggering condition 1":
2> if that primary CPICH is included in the "cells triggered" in the corresponding variable TRIGGERED_1F_EVENT:
3> remove that primary CPICH from "cells triggered" in the corresponding variable TRIGGERED_1F_EVENT.
Equation 1 (Triggering condition for pathloss)
Equation 2 (Triggering condition for all the other measurement quantities)
Equation 3 (Leaving triggering condition for pathloss)
Equation 4 (Leaving triggering condition for all the other measurement quantities)
The variables in the formula are defined as follows:
MOld is the measurement result of a cell that becomes worse than an absolute threshold
CIOOld is the individual cell offset for the cell becoming worse than the absolute threshold. Otherwise it is equal to 0.
T1f is an absolute threshold
H1f is the hysteresis parameter for the event 1f.
If the measurement results are pathloss or CPICH-Ec/No then MOld is expressed as ratios.
If the measurement result is CPICH-RSCP then MOld is expressed in mW.
Figure 14.1.2.6-1 [Informative]: Event-triggered report when a Primary CPICH becomes worse than an absolute threshold
In this figure, the parameters hysteresis and time to trigger, as well as the cell individual offsets for all cells are equal to 0.
14.1.2.7 Reporting event 1J: A non-active E-DCH but active DCH primary CPICH becomes better than an active E-DCH primary CPICH
When an intra-frequency measurement configuring event 1j is set up, the UE shall:
1> create a variable TRIGGERED_1J_EVENT related to that measurement, which shall initially be empty;
1> delete this variable when the measurement is released.
When event 1J is configured in the UE, the UE shall:
1> if "Measurement quantity" is "pathloss" and Equation 1 below is fulfilled for one or more primary CPICHs, or if "Measurement quantity" is "CPICH Ec/N0" or "CPICH RSCP", and Equation 2 below is fulfilled for one or more primary CPICHs, for each of these primary CPICHs:
2> if all required reporting quantities are available for that cell; and
2> if the equations have been fulfilled for a time period indicated by "Time to trigger", and if the primary CPICH that is better is not included in the E-DCH active set but included in DCH active set and the other primary CPICH is any of the primary CPICHs included in the E-DCH active set, and if that first primary CPICH is not included in the "cells triggered" in the variable TRIGGERED_1J_EVENT:
3> include that primary CPICH in the "cells recently triggered" in the variable TRIGGERED_1J_EVENT.
1> if the value of "Replacement activation threshold" for this event is less than or equal to the current number of cells in the E-DCH active set or equal to 0 and if any primary CPICHs are stored in the "cells recently triggered" in the variable TRIGGERED_1J_EVENT:
2> if "Reporting interval" for this event is not equal to 0:
3> if the IE "Periodical reporting running" in the variable TRIGGERED_1J_EVENT is set to FALSE:
4> start a timer for with the value of "Reporting interval" for this event and set the IE "Periodical reporting running" in the variable TRIGGERED_1J_EVENT to TRUE.
3> set "sent reports" for that primary CPICH in the variable TRIGGERED_1J_EVENT to 1.
2> send a measurement report with IEs set as below:
3> set in "intra-frequency measurement event results": "Intrafrequency event identity" to "1J"; and
3> include in "cell measurement event results" all entries of the "cells recently triggered" in the variable TRIGGERED_1J_EVENT not in the E-DCH active set but included in DCH active set as well as the "primary CPICH info" of all the primary CPICHs in the E-DCH active set for which the measured value is worse (i.e. greater for pathloss and less for the other measurement quantities) than the one of the entry in "cell recently triggered" that has the best measured value taking into account their cell individual offset. The "primary CPICH info" for those cells shall be ordered according to their measured value taking into account their cell individual offset, beginning with the best cell to the worst one;
3> set the IE "measured results" and the IE "additional measured results" according to subclause 8.4.2, not taking into account the cell individual offset for each cell.
2> move all entries from "cells recently triggered" to "cells triggered" in the variable TRIGGERED_1J_EVENT.
1> if the timer for the periodical reporting has expired:
2> if any primary CPICH is included in the "cells triggered" in the variable TRIGGERED_1J_EVENT, and not included in the current E-DCH active set but included in DCH active set:
3> if "Reporting interval" for this event is not equal to 0, and if "Amount of reporting" is greater than "sent reports" stored for that primary CPICH, in "cells triggered" in the variable TRIGGERED_1J_EVENT:
4> increment the stored counter "sent reports" for all CPICH in "cell triggered" in variable TRIGGERED_1J_EVENT;
4> start a timer with the value of "Reporting interval" for this event;
4> send a measurement report with IEs set as below:
5> set in "intra-frequency measurement event results": "Intrafrequency event identity" to "1J"; and
5> include in "cell measurement event results" all entries of the variable TRIGGERED_1J_EVENT with value of IE "sent report" equal to or smaller than value of "Amount of reporting" and that are not part of the E-DCH active set but included in DCH active set as well as the "primary CPICH info" of all the primary CPICHs in the E-DCH active set for which the measured value is worse (i.e. greater for pathloss and less for the other measurement quantities) than the one of the entry in "cell triggered" that has the best measured value, ordering the "primary CPICH info" according to their measured value beginning with the best cell to the worst one, taking into account the cell individual offset for each cell;
5> set the IE "measured results" and the IE "additional measured results" according to subclause 8.4.2, not taking into account the cell individual offset for each cell.
4> if "sent reports" in variable TRIGGERED_1J_EVENT is equal to "Amount of reporting" for all entries:
5> set the IE "Periodical Reporting running" in the variable TRIGGERED_1J_EVENT to FALSE and disable the timer for the periodical reporting.
1> if "Measurement quantity" is "pathloss" and Equation 3 below is fulfilled for a primary CPICH, or if "Measurement quantity" is "CPICH Ec/N0" or "CPICH RSCP", and Equation 4 below is fulfilled for a primary CPICH or;
1> if a primary CPICH is added to the E-DCH active set:
2> if that primary CPICH is included in the "cells triggered" or "cells recently triggered" in the variable TRIGGERED_1J_EVENT:
3> remove the entry of that primary CPICH from "cells triggered" or "cells recently triggered" in the variable TRIGGERED_1J_EVENT.
3> if no entry in the variable TRIGGERED_1J_EVENT has a value of "sent reports" smaller than "Amount of reporting" or
3> if there is no entry in the variable TRIGGERED_1J_EVENT:
4> if the reporting interval timer is running:
5> stop the reporting interval timer;
5> set the IE "Periodical reporting running" in the variable TRIGGERED_1J_EVENT to FALSE.
Equation 1 (Triggering condition for pathloss)
Equation 2 (Triggering condition for all the other measurement quantities)
Equation 3 (Leaving triggering condition for pathloss)
Equation 4 (Leaving triggering condition for all the other measurement quantities)
The variables in the formula are defined as follows:
MNew is the measurement result of the cell not included in the E-DCH active set but included in DCH active set.
CIONew is the individual cell offset for the cell not included in the E-DCH active set but included in DCH active set becoming better than the cell in the E-DCH active set if an individual cell offset is stored for that cell. Otherwise it is equal to 0.
For pathloss:
MInAS is the measurement result of the cell in the E-DCH active set with the highest measurement result.
For other measurement quantities:
MInAS is the measurement result of the cell in the E-DCH active set with the lowest measurement result.
CIOInAS is the individual cell offset for the cell in the E-DCH active set that is becoming worse than the new cell.
H1J is the hysteresis parameter for the event 1J.
If the measurement results are pathloss or CPICH-Ec/No then MNew and MinAS are expressed as ratios.
If the measurement result is CPICH-RSCP then MNew and MinAS are expressed in mW.
Figure 14.1.2.7-1 [Informative]: A primary CPICH that is not included in the E-DCH active set but included in DCH active set becomes better than a primary CPICH that is in the E-DCH active set
In this figure, the parameters hysteresis and time to trigger, as well as the cell individual offsets for all cells are equal to 0 and replacement activation threshold is equal to 0 or 1 or 2. In this example the cells belonging to primary CPICH 1 and 2 are in the E-DCH active set, but the cells transmitting primary CPICH 3 and CPICH 4 are not (yet) in the E-DCH active set but included in DCH active set.
The first measurement report is sent when primary CPICH 4 becomes better than primary CPICH 2. The "cell measurement event result" of the measurement report contains the information of primary CPICH 4 and CPICH 2.
Assuming that the E-DCH active set has been updated after the first measurement report (E-DCH active set is now primary CPICH 1 and primary CPICH 4), the second report is sent when primary CPICH 3 becomes better than primary CPICH 1. The "cell measurement event result" of the second measurement report contains the information of primary CPICH 3 and primary CPICH 1.