10.2.17 MEASUREMENT CONTROL
25.3313GPPProtocol specificationRadio Resource Control (RRC)Release 17TS
This message is sent by UTRAN to setup, modify or release a measurement in the UE.
RLC-SAP: AM
Logical channel: DCCH
Direction: UTRANUE
|
Information Element/Group name |
Need |
Multi |
Type and reference |
Semantics description |
Version |
|---|---|---|---|---|---|
|
Message Type |
MP |
Message Type |
|||
|
UE information elements |
|||||
|
RRC transaction identifier |
MP |
RRC transaction identifier 10.3.3.36 |
|||
|
Integrity check info |
CH |
Integrity check info 10.3.3.16 |
|||
|
Measurement Information elements |
|||||
|
Measurement Identity |
CV-command2 |
Measurement Identity 10.3.7.48 |
|||
|
Measurement Command |
MP |
Measurement Command 10.3.7.46 |
|||
|
Release Some Measurements |
CV-command3 |
Release some measurements 10.3.7.46b |
REL-12 |
||
|
Measurement Reporting Mode |
OP |
Measurement Reporting Mode 10.3.7.49 |
|||
|
Additional measurements list |
OP |
Additional measurements list 10.3.7.1 |
|||
|
CHOICE Measurement type |
CV-command |
||||
|
>Intra-frequency measurement |
Intra-frequency measurement 10.3.7.36 |
||||
|
>Inter-frequency measurement |
Inter-frequency measurement 10.3.7.16 |
||||
|
>Inter-RAT measurement |
Inter-RAT measurement 10.3.7.27 |
||||
|
>UE positioning measurement |
UE positioning measurement 10.3.7.100 |
||||
|
>Traffic Volume measurement |
Traffic Volume measurement 10.3.7.68 |
||||
|
>Quality measurement |
Quality measurement 10.3.7.56 |
||||
|
>UE internal measurement |
UE internal measurement 10.3.7.77 |
||||
|
>CSG Proximity detection |
CSG Proximity detection 10.3.7.123 |
REL-9 |
|||
|
>E-UTRA measurement for CELL_FACH |
E-UTRA measurement for CELL_FACH 10.3.7.137 |
REL-11 |
|||
|
>Application layer measurement configuration |
Application layer measurement configuration 10.3.7.143 |
REL-14 |
|||
|
CELL_DCH measurement occasion info LCR |
OP |
CELL_DCH measurement occasion info LCR 10.3.7.126 |
REL-9 |
||
|
Measurement Scaling Factor |
CV_Measurement |
Enumerated (SF_UTRA_CF1, SF_UTRA_CF2) |
The Measurement Scaling Factor is used to scale the measurement performance for UTRA/E-UTRA frequencies configured in CELL_DCH as specified in [19]. Even if no UTRA or E-UTRA frequency is configured for reduced measurement performance, the network may configure a scaling factor and configure any of the scaling factor values [19]. |
REL-12 |
|
|
Physical channel information elements |
|||||
|
DPCH compressed mode status info |
OP |
DPCH compressed mode status info 10.3.6.34 |
|
Condition |
Explanation |
|
Command2 |
The IE is mandatory present if the IE "Measurement Command" is set to "Setup", "Modify" or "Release", otherwise the IE is not needed. |
|
Command3 |
The IE is mandatory present if the IE "Measurement Command" is set to "ReleaseSome", otherwise the IE is not needed. |
|
Command |
The IE is mandatory present if the IE "Measurement command" is set to "Setup", optional if the IE "Measurement command" is set to "modify", otherwise the IE is not needed. |
|
Measurement |
The IE is optionally present if the IE "Inter-frequency measurement" and/or IE "Inter-RAT measurement" is present, otherwise the IE is not needed. |