10.2.17 MEASUREMENT CONTROL

25.3313GPPProtocol specificationRadio Resource Control (RRC)Release 17TS

This message is sent by UTRAN to setup, modify or release a measurement in the UE.

RLC-SAP: AM

Logical channel: DCCH

Direction: UTRANUE

Information Element/Group name

Need

Multi

Type and reference

Semantics description

Version

Message Type

MP

Message Type

UE information elements

RRC transaction identifier

MP

RRC transaction identifier 10.3.3.36

Integrity check info

CH

Integrity check info 10.3.3.16

Measurement Information elements

Measurement Identity

CV-command2

Measurement Identity 10.3.7.48

Measurement Command

MP

Measurement Command 10.3.7.46

Release Some Measurements

CV-command3

Release some measurements 10.3.7.46b

REL-12

Measurement Reporting Mode

OP

Measurement Reporting Mode 10.3.7.49

Additional measurements list

OP

Additional measurements list 10.3.7.1

CHOICE Measurement type

CV-command

>Intra-frequency measurement

Intra-frequency measurement 10.3.7.36

>Inter-frequency measurement

Inter-frequency measurement 10.3.7.16

>Inter-RAT measurement

Inter-RAT measurement 10.3.7.27

>UE positioning measurement

UE positioning measurement 10.3.7.100

>Traffic Volume measurement

Traffic Volume measurement 10.3.7.68

>Quality measurement

Quality measurement 10.3.7.56

>UE internal measurement

UE internal measurement 10.3.7.77

>CSG Proximity detection

CSG Proximity detection 10.3.7.123

REL-9

>E-UTRA measurement for CELL_FACH

E-UTRA measurement for CELL_FACH 10.3.7.137

REL-11

>Application layer measurement configuration

Application layer measurement configuration 10.3.7.143

REL-14

CELL_DCH measurement occasion info LCR

OP

CELL_DCH measurement occasion info LCR

10.3.7.126

REL-9

Measurement Scaling Factor

CV_Measurement

Enumerated (SF_UTRA_CF1, SF_UTRA_CF2)

The Measurement Scaling Factor is used to scale the measurement performance for UTRA/E-UTRA frequencies configured in CELL_DCH as specified in [19]. Even if no UTRA or E-UTRA frequency is configured for reduced measurement performance, the network may configure a scaling factor and configure any of the scaling factor values [19].

REL-12

Physical channel information elements

DPCH compressed mode status info

OP

DPCH compressed mode status info

10.3.6.34

Condition

Explanation

Command2

The IE is mandatory present if the IE "Measurement Command" is set to "Setup", "Modify" or "Release", otherwise the IE is not needed.

Command3

The IE is mandatory present if the IE "Measurement Command" is set to "ReleaseSome", otherwise the IE is not needed.

Command

The IE is mandatory present if the IE "Measurement command" is set to "Setup", optional if the IE "Measurement command" is set to "modify", otherwise the IE is not needed.

Measurement

The IE is optionally present if the IE "Inter-frequency measurement" and/or IE "Inter-RAT measurement" is present, otherwise the IE is not needed.