G.1 Transmitter measurements

25.1413GPPBase Station (BS) conformance testing (FDD)Release 17TS

Table G.1: Equipment accuracy for transmitter measurements

Test

Equipment accuracy

Range over which equipment accuracy applies

6.2.1 Maximum Output Power

Not critical

Not critical

6.2.2 CPICH Power accuracy

Not critical

Not critical

6.3 Frequency error

± 10 Hz + timebase = [12] Hz

Measurements in the range ±500 Hz.

6.4.2 Power control steps

0.1 dB for one 1 dB step

0.1 dB for ten 1 dB steps

Pmax,c – 3 dB to Pmax,c – 28 dB

6.4.3 Power control dynamic range

0.2 dB relative code domain power accuracy

Pmax,c – 3 dB to Pmax,c – 28 dB

6.4.4 Total power dynamic range

0.3 dB relative error over 18 dB

Pmax,c to Pmax,c – 18 dB

6.4.5 IPDL time mask

Not critical

Not critical

6.5.1 Occupied Bandwidth

100 kHz

±1 MHz of the minimum requirement

6.5.2.1 Spectrum emission mask

Not critical

Not critical

6.5.2.2 ACLR/CACLR

 dB

Measurements in the range ±3 dB of the minimum requirement at signal power = Pmax,c

6.5.3 Spurious emissions

Not critical

Not critical

6.6 Transmit intermodulation (interferer requirements)

Not critical

Not critical

6.7.1 EVM

2.5 %

(for single code)

Measurements in the range 12.5% to 22.5% at signal power = Pmax,c -3 dB to Pmax,c – 18 dB

6.7.2 Peak code Domain error

±1.0 dB

Measurements in the range -30 to -36 dB at signal power = Pmax

6.7.3 Time alignment error in TX diversity, MIMO, DC‑HSDPA and DB‑DC‑HSDPA transmission

0.1 Tc

6.7.4 Relative Code Domain Error

±1.0 dB

Measurements in the range -18 to -24 dB at signal power = Pmax,c

Annex H.3 Transmitted code power (absolute)

±0.9 dB

Pmax,c – 3 dB to Pmax,c – 28 dB

Annex H.3 Transmitted code power (relative)

±0.2 dB

Pmax,c – 3 dB to Pmax,c – 28 dB

Annex H.4 Transmitted carrier power

0.3 dB relative error over 18 dB

Pmax,c to Pmax,c – 18 dB