A.7 Reference measurement channels for UL RACH

25.1413GPPBase Station (BS) conformance testing (FDD)Release 17TS

The parameters for the UL RACH reference measurement channels are specified in Table A.7.

Table A.7: Reference measurement channels for UL RACH

Parameter

Unit

RACH

CRC

16

bits

Channel Coding

Rate ½ conv. coding

TTI

20

ms

TB size

168, 360

bits

Rate Matching

Repetition

Number of diversity antennas

2

Preamble detection window size

256

chips

Ratio of preamble power and total message power (*)

0

 dB

Power ratio of RACH Control/Data TB = 168

-2.69

 dB

Power ratio of Control/Data TB = 360

-3.52

 dB

NOTE *: If Power Offset Pp-m is used to adjust the power offset, Power Offset Pp-m shall be equal to -5 dB.