7 Applicability overview

25.1133GPPBase station (BS) and repeater electromagnetic compatibility (EMC)Release 17TS

7.1 Emission

Table 3: Emission applicability

Equipment test requirement

Reference

Reference

Phenomenon

Application

BS equipment

Ancillary equipment

Repeater

subclause in the present document

Standard

Radiated emission (NOTE 2)

Enclosure

applicable

applicable

8.3.1

ITU-R SM.329 [12]

Radiated emission

Enclosure

applicable

8.3.2

CISPR 32 [28]

Conducted emission

DC power input/output port

applicable

applicable

applicable

8.4

CISPR 32 [28],
CISPR 16‑1-1 [14]

Conducted emission

AC mains input/output port

applicable

applicable

applicable

8.5

CISPR 32 [28]

Harmonic current emissions

AC mains input port

applicable

applicable

applicable

8.6

IEC 61000-3-2 [15] or
IEC 61000-3-12 [25]

Voltage fluctuations and flicker

AC mains input port

applicable

applicable

applicable

8.7

IEC 61000-3-3 [16] or
IEC 61000-3-11 [26]

Conducted emission

Telecommunica-tion port

applicable

applicable

applicable

8.8

CISPR 32 [28]

NOTE 1: Spurious emissions from antenna connector shall be measured according to TS 25.141 [3] and TS 25.142 [4] and TS 25.143 [11].

NOTE 2: The radiated emissions requirement for the BS equipment covers radiated emissions in the spurious domain. Note that in ETSI standards and in 3GPP GERAN specifications it is considered a part of radio aspects.

7.2 Immunity

Table 4: Immunity applicability

Equipment test requirement

Reference

Reference

Phenomenon

Application

BS equipment

Ancillary equipment

Repeater

subclause in the present document

standard

RF electro­magnetic field (80 – 6000 MHz)

Enclosure

applicable

applicable

applicable

9.3

IEC 61000‑4‑3 [18]

Electrostatic discharge

Enclosure

applicable

applicable

applicable

9.4

IEC 61000‑4‑2 [17]

Fast transients common mode

Signal, telecommunications and control ports, DC and AC power input ports

applicable

applicable

applicable

9.5

IEC 61000‑4‑4 [19]

RF common mode

0,15 – 80 MHz

Signal, telecommunications and control ports, DC and AC power input ports

applicable

applicable

applicable

9.6

IEC 61000‑4‑6 [21]

Voltage dips and interruptions

AC mains power input ports

applicable

applicable

applicable

9.7

IEC 61000‑4‑11

Surges, common and differential mode

AC power input ports and telecommunications port

applicable

applicable

applicable

9.8

IEC 61000‑4‑5 [20]

7.3 Applicability of requirements in TS 37.113

For a BS that is UTRA (single-RAT) capable only, the requirements in the present document are applicable and additional conformance to TS 37.113 [27] is optional. For a BS additionally conforming to TS 37.113 [27], conformance to some of the emission test requirements in the present document can be demonstrated through the corresponding requirements in TS 37.113 [27] as listed in Table 4A and conformance to some of the immunity test requirements in the present document can be demonstrated through the corresponding requirements in TS 37.113 [27] as listed in Table 4B.

Table 4A: Alternative emission test requirements for a BS additionally conforming to TS 37.113 [27]

Phenomenon

Application

Clause in the present document

Alternative clause in TS 37.113 [27]

Radiated emission

Enclosure

8.3.1

8.2.1

Conducted emission

DC power input/output port

8.4

8.3

Conducted emission

AC mains input/output port

8.5

8.4

Harmonic current emissions

AC mains input port

8.6

8.5

Voltage fluctuations and flicker

AC mains input port

8.7

8.6

Conducted emission

Telecommunication port

8.8

8.7

Table 4B: Alternative immunity test requirements for a BS additionally conforming to TS 37.113 [27]

Phenomenon

Application

Clause in the present document

Alternative clause in TS 37.113 [27]

RF electro­magnetic field (80 – 6000 MHz)

Enclosure

9.3

9.2

Electrostatic discharge

Enclosure

9.4

9.3

Fast transients common mode

Signal, telecommunications and control ports, DC and AC power input ports

9.5

9.4

RF common mode (0,15 – 80 MHz)

Signal, telecommunications and control ports, DC and AC power input ports

9.6

9.5

Voltage dips and interruptions

AC mains power input ports

9.7

9.6

Surges, common and differential mode

AC power input ports and telecommunications port

9.8

9.7