D.4 E-UTRA power level

38.521-43GPPNRPart 4: PerformanceRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification

D.4.1 E-UTRA power level (conducted)

Table D.4.1-1: DL power level for E-UTRA (conducted)

Parameter

Value

Comments

DL signal level

RS EPRE -85.0 dBm/15 kHz

The power level is specified at each UE Rx antenna

D.4.2 E-UTRA power level (radiated)

Table D.4.2-1: Downlink power levels for E-UTRA (radiated)

Parameter

Value

Comments

DL signal level

RS EPRE -100 dBm/15 kHz

The power level is specified at each UE Rx antenna

Annex E (normative): Environmental conditions

FFS

Annex F (normative):
Measurement uncertainties and test tolerances

The requirements of this clause apply to all tests in the present document.