D.4 E-UTRA power level
38.521-43GPPNRPart 4: PerformanceRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
D.4.1 E-UTRA power level (conducted)
Table D.4.1-1: DL power level for E-UTRA (conducted)
Parameter |
Value |
Comments |
DL signal level |
RS EPRE -85.0 dBm/15 kHz |
The power level is specified at each UE Rx antenna |
D.4.2 E-UTRA power level (radiated)
Table D.4.2-1: Downlink power levels for E-UTRA (radiated)
Parameter |
Value |
Comments |
DL signal level |
RS EPRE -100 dBm/15 kHz |
The power level is specified at each UE Rx antenna |
Annex E (normative): Environmental conditions
FFS
Annex F (normative):
Measurement uncertainties and test tolerances