A.1 General

38.521-43GPPNRPart 4: PerformanceRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification

A.1.1 Throughput definition

The throughput values defined in the measurement channels specified in Annex A, are calculated and are valid per codeword. For multi-codeword transmissions, the throughput referenced in the minimum requirements is the sum of throughputs of all codewords.

A.1.2 TDD UL-DL configurations for FR1

TDD UL-DL configurations for performance requirements are provided in Tables A.1.2-1, A.1.2-2, and A.1.2-3.

Table A.1.2-1: TDD UL-DL configuration for SCS 15 kHz

Parameter

Unit

UL-DL pattern

FR1.15-1

TDD Slot Configuration pattern (Note 1)

DDDSU

Special Slot Configuration (Note 2)

10D+2G+2U

referenceSubcarrierSpacing

kHz

15

pattern1

dl-UL-TransmissionPeriodicity

ms

5

nrofDownlinkSlots

3

nrofDownlinkSymbols

10

nrofUplinkSlot

1

nrofUplinkSymbols

2

The number of slots between PDSCH and corresponding HARQ-ACK information (Note 3)

4 if mod(i,5) = 0
3 if mod(i,5) = 1
2 if mod(i,5) = 2
6 if mod(i,5) = 3

Note 1: D denotes a slot with all DL symbols; S denotes a slot with a mix of DL, UL and guard symbols; U denotes a slot with all UL symbols. The field is for information.

Note 2: D, G, U denote DL, guard and UL symbols, respectively. The field is for information.

Note 3: i is the slot index per frame; i = {0,…,9}.

Table A.1.2-2: TDD UL-DL configuration for SCS 30 kHz

Parameter

Unit

UL-DL pattern

FR1.30-1

FR1.30-2

FR1.30-3

FR1.30-4

FR1.30-5

FR1.30-6

TDD Slot Configuration pattern (Note 1)

7DS2U

DDDSU

DDDSUDDSUU

DDDSUUDDDD

DSUU

DS1S2U

Special Slot Configuration (Note 2)

6D+4G+4U

10D+2G+2U

10D+2G+2U

6D+4G+4U

12D+2G

S1: 10D+2G+2U
S2: 12D+2G+0U

referenceSubcarrierSpacing

kHz

30

30

30

30

30

30

pattern1

dl-UL-TransmissionPeriodicity

ms

5

2.5

2.5

3

2

1

nrofDownlinkSlots

7

3

3

3

1

1

nrofDownlinkSymbols

6

10

10

6

12

10

nrofUplinkSlot

2

1

1

2

2

0

nrofUplinkSymbols

4

2

2

4

0

2

pattern2

dl-UL-TransmissionPeriodicity

ms

N/A

N/A

2.5

2

N/A

1

nrofDownlinkSlots

N/A

N/A

2

4

N/A

0

nrofDownlinkSymbols

N/A

N/A

10

0

N/A

12

nrofUplinkSlot

N/A

N/A

2

0

N/A

1

nrofUplinkSymbols

N/A

N/A

2

0

N/A

0

The number of slots between PDSCH and corresponding HARQ-ACK information (Note 3)

8 if mod(i,10) = 0
7 if mod(i,10) = 1
6 if mod(i,10) = 2
5 if mod(i,10) = 3
5 if mod(i,10) = 4
4 if mod(i,10) = 5
3 if mod(i,10) = 6
2 if mod(i,10) = 7

4 if mod(i,5) = 0
3 if mod(i,5) = 1
2 if mod(i,5) = 2
6 if mod(i,5) = 3

4 if mod(i,10) = 0
3 if mod(i,10) = 1
2 if mod(i,10) = 2
5 if mod(i,10) = 3
3 if mod(i,10) = 5
3 if mod(i,10) = 6
2 if mod(i,10) = 7

5 if mod(i,10) = 0
4 if mod(i,10) = 1
3 if mod(i,10) = 2
2 if mod(i,10) = 3
8 if mod(i,10) = 6
7 if mod(i,10) = 7
6 if mod(i,10) = 8
5 if mod(i,10) = 9

3 if mod(i,4) = 0
2 if mod(i,4) = 1

3 if mod(i,4) = 0
2 if mod(i,4) = 1
3 if mod(i,4) = 2

Note 1: D denotes a slot with all DL symbols; S denotes a slot with a mix of DL, UL and guard symbols; U denotes a slot with all UL symbols. The field is for information.

Note 2: D, G, U denote DL, guard and UL symbols, respectively. The field is for information.

Note 3: i is the slot index per frame; i = {0,…,19}

Table A.1.2-2a: TDD UL-DL configuration for SCS 30 kHz for DCI-based dynamic UL/DL detection

Parameter

Unit

UL-DL pattern

FR1.30-1A

TDD Slot Configuration pattern (Note 1)

7DS2U

Special Slot Configuration (Note 2)

6D+4G+4U

referenceSubcarrierSpacing

kHz

N/A

pattern1 (Note 4)

dl-UL-TransmissionPeriodicity

ms

N/A

nrofDownlinkSlots

N/A

nrofDownlinkSymbols

N/A

nrofUplinkSlot

N/A

nrofUplinkSymbols

N/A

PDCCH DCI Configuration

DCI Format

1-1 for slot indices with mod(i,10) = 0,1,2,3,4,5,6,7

Scheduled Grant

Symbol 2-13 for slot indices with mod(i,10) = 0,1,2,3,4,5,6 and Symbol 2-5 for slot indices with mod(i,10) = 7

The number of slots between PDSCH and corresponding HARQ-ACK information (Note 3)
(PDSCH-to-HARQ-timing-indicator)

8 if mod(i,10) = 0
7 if mod(i,10) = 1
6 if mod(i,10) = 2
5 if mod(i,10) = 3
5 if mod(i,10) = 4
4 if mod(i,10) = 5
3 if mod(i,10) = 6
2 if mod(i,10) = 7

Note 1: D denotes a slot with all DL symbols; S denotes a slot with a mix of DL, UL and guard symbols; U denotes a slot with all UL symbols. The field is for information.

Note 2: D, G and U denote DL, guard and UL symbols, respectively. The field is for information.

Note 3: i is the slot index per frame; i = {0,…,19}

Note 4: Do not configure tdd-UL-DL-ConfigurationCommon using RRC configuration.

A.1.3 TDD UL-DL configurations for FR2

TDD UL-DL configurations for performance requirements are provided in Tables A.1.3-1, A.1.3-2.

Table A.1.3-1: TDD UL-DL configuration for SCS 60 kHz

Parameter

Unit

UL-DL pattern

FR2.60-1

TDD Slot Configuration pattern (Note 1)

DDSU

Special Slot Configuration (Note 2)

11D+3G+0U

referenceSubcarrierSpacing

kHz

60

pattern1

dl-UL-TransmissionPeriodicity

ms

1

nrofDownlinkSlots

2

nrofDownlinkSymbols

11

nrofUplinkSlot

1

nrofUplinkSymbols

0

The number of slots between PDSCH and corresponding HARQ-ACK information (Note 3)

3 if mod(i,4) = 0
2 if mod(i,4) = 1
5 if mod(i,4) = 2

Note 1: D denotes a slot with all DL symbols; S denotes a slot with a mix of DL, UL and guard symbols; U denotes a slot with all UL symbols. The field is for information.

Note 2: D, G, U denote DL, guard and UL symbols, respectively. The field is for information.

Note 3: i is the slot index per frame; i = {0,…,39}

Table A.1.3-2: TDD UL-DL configuration for SCS 120 kHz

Parameter

Unit

UL-DL pattern

FR2.120-1

FR2.120-2

TDD Slot Configuration pattern (Note 1)

DDDSU

DDSU

Special Slot Configuration (Note 2)

10D+2G+2U

11D+3G+0U

referenceSubcarrierSpacing

kHz

120

120

pattern1

dl-UL-TransmissionPeriodicity

ms

0.625

0.5

nrofDownlinkSlots

3

2

nrofDownlinkSymbols

10

11

nrofUplinkSlot

1

1

nrofUplinkSymbols

2

0

The number of slots between PDSCH and corresponding HARQ-ACK information(Note 3)

4 if mod(i,5) = 0
3 if mod(i,5) = 1
2 if mod(i,5) = 2
6 if mod(i,5) = 3

3 if mod(i,4) = 0
2 if mod(i,4) = 1
5 if mod(i,4) = 2

Note 1: D denotes a slot with all DL symbols; S denotes a slot with a mix of DL, UL and guard symbols; U denotes a slot with all UL symbols. The field is for information.

Note 2: D, G, U denote DL, guard and UL symbols, respectively. The field is for information.

Note 3: i is the slot index per frame; i = {0,…,79}

Table A.1.3-2a: TDD UL-DL configuration for SCS 120 kHz for DCI-based dynamic UL/DL detection

Parameter

Unit

UL-DL pattern

FR2.120-1A

TDD Slot Configuration pattern (Note 1)

DDDSU

Special Slot Configuration (Note 2)

10D+2G+2U

referenceSubcarrierSpacing

kHz

N/A

pattern1 (Note 4)

dl-UL-TransmissionPeriodicity

ms

N/A

nrofDownlinkSlots

N/A

nrofDownlinkSymbols

N/A

nrofUplinkSlot

N/A

nrofUplinkSymbols

N/A

PDCCH DCI Configuration

DCI Format

1-1 for slot indices with mod(i,5) = 0,1,2,3

Scheduled Grant

Symbol 1-13 for slot indices with mod(i,5) = 0,1,2 and Symbol 1-9 for slot indices with mod(i,5) = 3

The number of slots between PDSCH and corresponding HARQ-ACK information(Note 3)

4 if mod(i,5) = 0
3 if mod(i,5) = 1
2 if mod(i,5) = 2
6 if mod(i,5) = 3

Note 1: D denotes a slot with all DL symbols; S denotes a slot with a mix of DL, UL and guard symbols; U denotes a slot with all UL symbols. The field is for information.

Note 2: D, G and U denote DL, guard and UL symbols, respectively. The field is for information.

Note 3: i is the slot index per frame; i = {0,…,79}

Note 4: Do not configure tdd-UL-DL-ConfigurationCommon using RRC configuration.