A.1 General
38.521-43GPPNRPart 4: PerformanceRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
A.1.1 Throughput definition
The throughput values defined in the measurement channels specified in Annex A, are calculated and are valid per codeword. For multi-codeword transmissions, the throughput referenced in the minimum requirements is the sum of throughputs of all codewords.
A.1.2 TDD UL-DL configurations for FR1
TDD UL-DL configurations for performance requirements are provided in Tables A.1.2-1, A.1.2-2, and A.1.2-3.
Table A.1.2-1: TDD UL-DL configuration for SCS 15 kHz
Parameter |
Unit |
UL-DL pattern |
|
FR1.15-1 |
|||
TDD Slot Configuration pattern (Note 1) |
DDDSU |
||
Special Slot Configuration (Note 2) |
10D+2G+2U |
||
referenceSubcarrierSpacing |
kHz |
15 |
|
pattern1 |
dl-UL-TransmissionPeriodicity |
ms |
5 |
nrofDownlinkSlots |
3 |
||
nrofDownlinkSymbols |
10 |
||
nrofUplinkSlot |
1 |
||
nrofUplinkSymbols |
2 |
||
The number of slots between PDSCH and corresponding HARQ-ACK information (Note 3) |
4 if mod(i,5) = 0 |
||
Note 1: D denotes a slot with all DL symbols; S denotes a slot with a mix of DL, UL and guard symbols; U denotes a slot with all UL symbols. The field is for information. Note 2: D, G, U denote DL, guard and UL symbols, respectively. The field is for information. Note 3: i is the slot index per frame; i = {0,…,9}. |
Table A.1.2-2: TDD UL-DL configuration for SCS 30 kHz
Parameter |
Unit |
UL-DL pattern |
||||||
FR1.30-1 |
FR1.30-2 |
FR1.30-3 |
FR1.30-4 |
FR1.30-5 |
FR1.30-6 |
|||
TDD Slot Configuration pattern (Note 1) |
7DS2U |
DDDSU |
DDDSUDDSUU |
DDDSUUDDDD |
DSUU |
DS1S2U |
||
Special Slot Configuration (Note 2) |
6D+4G+4U |
10D+2G+2U |
10D+2G+2U |
6D+4G+4U |
12D+2G |
S1: 10D+2G+2U |
||
referenceSubcarrierSpacing |
kHz |
30 |
30 |
30 |
30 |
30 |
30 |
|
pattern1 |
||||||||
dl-UL-TransmissionPeriodicity |
ms |
5 |
2.5 |
2.5 |
3 |
2 |
1 |
|
nrofDownlinkSlots |
7 |
3 |
3 |
3 |
1 |
1 |
||
nrofDownlinkSymbols |
6 |
10 |
10 |
6 |
12 |
10 |
||
nrofUplinkSlot |
2 |
1 |
1 |
2 |
2 |
0 |
||
nrofUplinkSymbols |
4 |
2 |
2 |
4 |
0 |
2 |
||
pattern2 |
||||||||
dl-UL-TransmissionPeriodicity |
ms |
N/A |
N/A |
2.5 |
2 |
N/A |
1 |
|
nrofDownlinkSlots |
N/A |
N/A |
2 |
4 |
N/A |
0 |
||
nrofDownlinkSymbols |
N/A |
N/A |
10 |
0 |
N/A |
12 |
||
nrofUplinkSlot |
N/A |
N/A |
2 |
0 |
N/A |
1 |
||
nrofUplinkSymbols |
N/A |
N/A |
2 |
0 |
N/A |
0 |
||
The number of slots between PDSCH and corresponding HARQ-ACK information (Note 3) |
8 if mod(i,10) = 0 |
4 if mod(i,5) = 0 |
4 if mod(i,10) = 0 |
5 if mod(i,10) = 0 |
3 if mod(i,4) = 0 |
3 if mod(i,4) = 0 |
||
Note 1: D denotes a slot with all DL symbols; S denotes a slot with a mix of DL, UL and guard symbols; U denotes a slot with all UL symbols. The field is for information. Note 2: D, G, U denote DL, guard and UL symbols, respectively. The field is for information. Note 3: i is the slot index per frame; i = {0,…,19} |
Table A.1.2-2a: TDD UL-DL configuration for SCS 30 kHz for DCI-based dynamic UL/DL detection
Parameter |
Unit |
UL-DL pattern |
|
FR1.30-1A |
|||
TDD Slot Configuration pattern (Note 1) |
7DS2U |
||
Special Slot Configuration (Note 2) |
6D+4G+4U |
||
referenceSubcarrierSpacing |
kHz |
N/A |
|
pattern1 (Note 4) |
|||
dl-UL-TransmissionPeriodicity |
ms |
N/A |
|
nrofDownlinkSlots |
N/A |
||
nrofDownlinkSymbols |
N/A |
||
nrofUplinkSlot |
N/A |
||
nrofUplinkSymbols |
N/A |
||
PDCCH DCI Configuration |
DCI Format |
1-1 for slot indices with mod(i,10) = 0,1,2,3,4,5,6,7 |
|
Scheduled Grant |
Symbol 2-13 for slot indices with mod(i,10) = 0,1,2,3,4,5,6 and Symbol 2-5 for slot indices with mod(i,10) = 7 |
||
The number of slots between PDSCH and corresponding HARQ-ACK information (Note 3) |
8 if mod(i,10) = 0 |
||
Note 1: D denotes a slot with all DL symbols; S denotes a slot with a mix of DL, UL and guard symbols; U denotes a slot with all UL symbols. The field is for information. Note 2: D, G and U denote DL, guard and UL symbols, respectively. The field is for information. Note 3: i is the slot index per frame; i = {0,…,19} Note 4: Do not configure tdd-UL-DL-ConfigurationCommon using RRC configuration. |
A.1.3 TDD UL-DL configurations for FR2
TDD UL-DL configurations for performance requirements are provided in Tables A.1.3-1, A.1.3-2.
Table A.1.3-1: TDD UL-DL configuration for SCS 60 kHz
Parameter |
Unit |
UL-DL pattern |
|
FR2.60-1 |
|||
TDD Slot Configuration pattern (Note 1) |
DDSU |
||
Special Slot Configuration (Note 2) |
11D+3G+0U |
||
referenceSubcarrierSpacing |
kHz |
60 |
|
pattern1 |
dl-UL-TransmissionPeriodicity |
ms |
1 |
nrofDownlinkSlots |
2 |
||
nrofDownlinkSymbols |
11 |
||
nrofUplinkSlot |
1 |
||
nrofUplinkSymbols |
0 |
||
The number of slots between PDSCH and corresponding HARQ-ACK information (Note 3) |
3 if mod(i,4) = 0 |
||
Note 1: D denotes a slot with all DL symbols; S denotes a slot with a mix of DL, UL and guard symbols; U denotes a slot with all UL symbols. The field is for information. Note 2: D, G, U denote DL, guard and UL symbols, respectively. The field is for information. Note 3: i is the slot index per frame; i = {0,…,39} |
Table A.1.3-2: TDD UL-DL configuration for SCS 120 kHz
Parameter |
Unit |
UL-DL pattern |
||
FR2.120-1 |
FR2.120-2 |
|||
TDD Slot Configuration pattern (Note 1) |
DDDSU |
DDSU |
||
Special Slot Configuration (Note 2) |
10D+2G+2U |
11D+3G+0U |
||
referenceSubcarrierSpacing |
kHz |
120 |
120 |
|
pattern1 |
dl-UL-TransmissionPeriodicity |
ms |
0.625 |
0.5 |
nrofDownlinkSlots |
3 |
2 |
||
nrofDownlinkSymbols |
10 |
11 |
||
nrofUplinkSlot |
1 |
1 |
||
nrofUplinkSymbols |
2 |
0 |
||
The number of slots between PDSCH and corresponding HARQ-ACK information(Note 3) |
4 if mod(i,5) = 0 |
3 if mod(i,4) = 0 |
||
Note 1: D denotes a slot with all DL symbols; S denotes a slot with a mix of DL, UL and guard symbols; U denotes a slot with all UL symbols. The field is for information. Note 2: D, G, U denote DL, guard and UL symbols, respectively. The field is for information. Note 3: i is the slot index per frame; i = {0,…,79} |
Table A.1.3-2a: TDD UL-DL configuration for SCS 120 kHz for DCI-based dynamic UL/DL detection
Parameter |
Unit |
UL-DL pattern |
|
FR2.120-1A |
|||
TDD Slot Configuration pattern (Note 1) |
DDDSU |
||
Special Slot Configuration (Note 2) |
10D+2G+2U |
||
referenceSubcarrierSpacing |
kHz |
N/A |
|
pattern1 (Note 4) |
dl-UL-TransmissionPeriodicity |
ms |
N/A |
nrofDownlinkSlots |
N/A |
||
nrofDownlinkSymbols |
N/A |
||
nrofUplinkSlot |
N/A |
||
nrofUplinkSymbols |
N/A |
||
PDCCH DCI Configuration |
DCI Format |
1-1 for slot indices with mod(i,5) = 0,1,2,3 |
|
Scheduled Grant |
Symbol 1-13 for slot indices with mod(i,5) = 0,1,2 and Symbol 1-9 for slot indices with mod(i,5) = 3 |
||
The number of slots between PDSCH and corresponding HARQ-ACK information(Note 3) |
4 if mod(i,5) = 0 |
||
Note 1: D denotes a slot with all DL symbols; S denotes a slot with a mix of DL, UL and guard symbols; U denotes a slot with all UL symbols. The field is for information. Note 2: D, G and U denote DL, guard and UL symbols, respectively. The field is for information. Note 3: i is the slot index per frame; i = {0,…,79} Note 4: Do not configure tdd-UL-DL-ConfigurationCommon using RRC configuration. |