7.3B.3 ΔRIB,c ΔRIBNC for EN-DC

38.521-33GPPNRPart 3: Range 1 and Range 2 Interworking operation with other radiosRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification

7.3B.3.0 General

For the UE which supports inter-band EN-DC or NE-DC configuration, the minimum requirement for reference sensitivity in Table 7.3.1-1 and Table 7.3.1-1a in TS.36101 [5], clause 7.3.2, 7.3A.2, 7.3C.2 in TS 38.101-1 [2] and clause 7.3.2, 7.3A.2 in TS 38.101-2 [3] shall be increased by the amount given in ΔRIB,c ΔRIBNC in Tables below where unless otherwise stated, the same ΔRIB,c, ΔRIBNC are applicable to NR band(s) part for DC configurations which have the same NR operating band combination. Unless otherwise stated, ΔRIB,c or ΔRIBNC is set to zero.

In case the UE supports more than one of band combinations for CA, SUL or DC, and an operating band belongs to more than one band combinations then

– When the operating band frequency range is ≤ 1 GHz, the applicable additional ΔRIB,c shall be the average value for all band combinations defined in clause 7.3A, 7.3B, 7.3C in this specification and 7.3A, 7.3B in TS 38.101-3 [4], truncated to one decimal place that apply for that operating band among the supported band combinations. In case there is a harmonic relation between low band UL and high band DL, then the maximum ΔRIB,c among the different supported band combinations involving such band shall be applied.

– When the operating band frequency range is > 1 GHz, the applicable additional ΔRIB,c shall be the maximum value for all band combinations defined in clause 7.3A, 7.3B, 7.3C in this specification and 7.3A, 7.3B in TS 38.101-3 [4] for the applicable operating bands.

Unless ΔRIB,c is specified for the NE-DC configuration, the specified ΔRIB,c for the EN-DC configuration including same bands as the corresponding NE-DC configuration is applicable for the NE-DC configuration.

The normative reference for this requirement is TS 38.101-3 [4] clause 7.3B.3.

7.3B.3.1 Reference sensitivity ΔRIB,c for Intra-band Contiguous EN-DC

FFS

7.3B.3.2 Reference sensitivity ΔRIB,c for Intra-band non-contiguous EN-DC

Table 7.3B.3.2-1: Intra-band non-contiguous EN-DC with one uplink configuration on E-UTRA for reference sensitivity

DC configuration

Aggregated channel bandwidth (LTE+NR)

Wgap / (MHz)

UL E-UTRA allocation

ΔRIBNC (dB)

Duplex mode

E-UTRA

NR

DC_3A_n3A

5MHz

5MHz

45.0 < Wgap ≤ 65.0

121

4.7

FDD

0.0 < Wgap ≤ 45.0

251

0

5MHz

10MHz

40.0 < Wgap ≤ 60.0

121

3.8

0.0 < Wgap ≤ 40.0

251

0

5MHz

15MHz

35.0 < Wgap ≤ 55.0

121

3.6

0.0 < Wgap ≤ 35.0

251

0

5MHz

20MHz

30.0 < Wgap ≤ 50.0

121

3.4

0.0 < Wgap ≤ 30.0

251

0

5MHz

25MHz

25.0 < Wgap ≤ 45.0

121

3.2

0.0 < Wgap ≤ 25.0

251

0

5MHz

30MHz

20.0 < Wgap ≤ 40.0

121

3.0

0.0 < Wgap ≤ 20.0

251

0

10MHz

5MHz

30.0 < Wgap ≤ 60.0

125

5.1

0.0 < Wgap ≤ 30.0

321

0

10MHz

10MHz

25.0 < Wgap ≤ 55.0

125

4.3

0.0 < Wgap ≤ 25.0

321

0

10MHz

15MHz

20.0 < Wgap ≤ 50.0

125

3.8

0.0 < Wgap ≤ 20.0

321

0

10MHz

20MHz

15.0 < Wgap ≤ 45.0

125

3.5

0.0 < Wgap ≤ 15.0

321

0

10MHz

25MHz

10.0 < Wgap ≤ 40.0

125

3.2

0.0 < Wgap ≤ 10.0

321

0

10MHz

30MHz

5.0 < Wgap ≤ 35.0

125

2.8

0.0 < Wgap ≤ 5.0

321

0

15MHz

5MHz

25.0 < Wgap ≤ 55.0

126

6.0

0.0 < Wgap ≤ 25.0

321

0

15MHz

10MHz

20.0 < Wgap ≤ 50.0

126

4.7

0.0 < Wgap ≤ 20.0

321

0

15MHz

15MHz

15.0 < Wgap ≤ 45.0

126

4.2

0.0 < Wgap ≤ 15.0

321

0

15MHz

20MHz

10.0 < Wgap ≤ 40.0

126

3.8

0.0 < Wgap ≤ 10.0

321

0

15MHz

25MHz

5.0 < Wgap ≤ 35.0

126

3.5

0.0 < Wgap ≤ 5.0

321

0

15MHz

30MHz

0.0 < Wgap ≤ 30.0

126

3.3

20MHz

5MHz

15.0 < Wgap ≤ 50.0

167

6.5

0.0 < Wgap ≤ 15.0

321

0

20MHz

10MHz

10.0 < Wgap ≤ 45.0

167

5.1

0.0 < Wgap ≤ 10.0

321

0

20MHz

15MHz

5.0 < Wgap ≤ 40.0

167

4.5

0.0 < Wgap ≤ 5.0

321

0

20MHz

20MHz

0.0 < Wgap ≤ 35.0

167

4.1

20MHz

25MHz

0.0 < Wgap ≤ 30.0

167

3.8

20MHz

30MHz

0.0 < Wgap ≤ 25.0

167

3.6

NOTE 1: UL resource blocks shall be located as close as possible to the downlink operating band but confined within the transmission.

NOTE 2: Wgap is the sub-block gap between the two sub-blocks.

NOTE 3: The table only applies when the centre frequency of E-UTRA carrier is higher than the NR carrier, and the ΔRIBNC applies to the NR DL carrier only.

NOTE 4: All combinations of channel bandwidths defined in Table 5.3B.1.3-1.

NOTE 5: UL resource blocks shall be located at RBstart=25.

NOTE 6: UL resource blocks shall be located at RBstart=35.

NOTE 7: UL resource blocks shall be located at RBstart=50.

7.3B.3.3 ΔRIB,c for Inter-band EN-DC within FR1

7.3B.3.3.1 ΔRIB,c for EN-DC in two bands

Table 7.3B.3.3.1-1: ΔRIB,c due to EN-DC(two bands)

Inter-band EN-DC configuration

E-UTRA or NR Band

ΔRIB,c (dB)

DC_1_n28

n28

0.2

DC_1_n51

n51

0.1

DC_1_n77

1

0.2

n77

0.5

DC_1_n78

n78

0.5

DC_2_n66

2

0.3

n66

0.3

DC_2_n78

2

0.2

n78

0.5

DC_3_n41

n41

03

0.54

DC_3_n51

3

0.2

n51

0.2

DC_3_n77, DC_3-3_n77

3

0.2

n77

0.5

DC_3_n78, DC_3-3_n78

3

0.2

n78

0.5

DC_5_n78

5

0.2

n78

0.5

DC_7_n8

n8

0.2

DC_7_n51

n51

0.2

DC_7_n71

n71

0.2

DC_7_n77, DC_7-7_n77

n77

0.5

DC_7_n78, DC_7-7_n78

n78

0.5

DC_8_n77

8

0.2

n77

0.5

DC_8_n78

8

0.2

n78

0.5

DC_11_n77

n77

0.5

DC_11_n78

n78

0.5

DC_12_n5

12

0.3

n5

0.5

DC_12_n66

12

0.5

DC_12_n78

12

0.2

n78

0.5

DC_18_n77

n77

0.5

DC_19_n77

n77

0.5

DC_19_n78

n78

0.5

DC_20_n51

n51

0.2

DC_20_n77

n77

0.5

DC_20_n78

n78

0.5

DC_21_n77

n77

0.5

DC_21_n78

n78

0.5

DC_25_n41,

DC_25-25_n41

n41

01

0.52

DC_26_n77

n77

0.5

DC_26_n78

n78

0.5

DC_28_n8

28

0.1

n8

0.2

DC_28_n51

n51

0.2

DC_28_n77

28

0.2

n77

0.5

DC_28_n78

28

0.2

n78

0.5

DC_30_n66

30

0.5

n66

0.4

DC_38_n78

38

0.4

n78

0.5

DC_39-n41

39

0.2

n41

0.2

DC_39_n78

n78

0.5

DC_39_n79

n79

0.5

DC_40_n77

40

0.4

n77

0.5

DC_40_n78

40

0.45

n78

0.55

DC_40_n79

n79

0.5

DC_41_n77

n77

0.5

DC_41_n78

n78

0.5

DC_41_n79

n79

0.5

DC_42_n51

n51

0.2

DC_66_n2

66

0.3

n2

0.3

DC_66_n25

66

0.3

n25

0.3

DC_66_n41

66

0.5

n41

0.51

12

DC_66_n78

66

0.2

n78

0.5

NOTE 1: The requirement is applied for UE transmitting on the frequency range of 2545-2690MHz.

NOTE 2: The requirement is applied for UE transmitting on the frequency range of 2496-2545MHz.

NOTE 3: Applicable for the frequency range of 2515-2690 MHz.

NOTE 4: Applicable for the frequency range of 2496-2515 MHz.

NOTE 5: Only applicable for UE supporting inter-band carrier aggregation with uplink in one E-UTRA band and without simultaneous Rx/Tx.

7.3B.3.3.2 ΔRIB,c for EN-DC in three bands

Table 7.3B.3.3.2-1: ΔRIB,c due to EN-DC (three bands)

Inter-band EN-DC configuration

E-UTRA or NR Band

ΔRIB,c (dB)

DC_1-3_n28

n28

0.2

DC_1-3_n77

1

0.2

3

0.2

n77

0.5

DC_1-3_n78

1

0.2

3

0.2

n78

0.5

DC_1_n3-n78

1

0.2

n3

0.2

n78

0.5

DC_1-5_n78

1

0.2

5

0.2

n78

0.5

DC_1-7_n28

n28

0.2

DC_1-7_n78

DC_1-7-7_n78

DC_1_n7-n78

1

0.2

7 or n7

0.2

n78

0.5

8

0.2

n77

0.5

DC_1-8_n78

8

0.2

n78

0.5

DC_1-11_n77

1

0.2

n77

0.5

n78

0.5

DC_1-18_n77

n77

0.5

DC_1-18_n78

n78

0.5

DC_1-19_n77

n77

0.5

DC_1-19_n78

n78

0.5

DC_1-19_n79

1

0.3

19

0.3

DC_1-20_n28

20

0.2

n28

0.2

DC_1-20_n78

n78

0.5

DC_1-21_n77

n77

0.5

DC_1-21_n78

1

0.2

n78

0.5

DC_1-28_n77

28

0.2

n77

0.5

DC_1-28_n78

DC_1_n28-n78

28 or n28

0.2

n78

0.5

DC_1_n28-n79

1

0.3

28

0.3

DC_1_n40-n78

n78

0.5

DC_1-41_n28

n28

0.2

DC_1-41_n77

n77

0.5

DC_1-41_n78

n78

0.5

DC_1-42_n77

1

0.2

42

0.5

n77

0.5

DC_1-42_n78

1

0.2

42

0.5

n78

0.5

DC_1-42_n79

42

0.5

DC_1_n77-n79

1

0.2

n77

0.5

DC_1_SUL_n77-n80

1

0.2

n77

0.5

DC_1_SUL_n77-n84

1

0.2

n77

0.5

DC_1_n78-n79

n78

0.5

DC_1_SUL_n78-n80

1

0.2

n78

0.5

DC_1-SUL_n78-n84

n78

0.5

DC_2-5_n66

2

0.3

n66

0.3

n71

0.2

DC_2-13_n66

DC_2-2-13_n66

2

0.3

n66

0.3

DC_2-29_n260

2

0

DC_2-14_n66
DC_2-2-14_n66

2

0.3

n66

0.3

DC_2-30_n5, DC_2-2-30_n5

2

0.4

30

0.5

DC_2_30_n66

2

0.4

30

0.5

n66

0.4

DC_2-66_n5

DC_2A-2A-66A_n5A

DC_2-66-66_n5

DC_2A-2A-66A-66A_n5A

DC_2-66-66-66_n5

2

0.3

66

0.3

DC_2-66_n41

2

0.3

66

0.5

n41

0.51

12

DC_2-66_n71B

2

0.3

66

0.3

DC_2-66_n78

DC_2-66-66_n78

2

0.3

66

0.3

n78

0.5

DC_3_n1-n77

3

0.2

n1

0.2

n77

0.5

DC_3_n1-n78

3

0.2

n1

0.2

n78

0.5

DC_3_n3-n77

3

0.2

n3

0.2

n77

0.5

DC_3_n3-n78

3

0.2

n3

0.2

n78

0.5

DC_3-5_n78

3

0.2

5

0.2

n78

0.5

DC_3-7_n8

n8

0.2

DC_3-7_n78

DC_3-7-7_n78

DC_3-3-7_n78

DC_3-3-7-7_n78

DC_3_n7-n78

3

0.2

7 or n7

0.2

n78

0.5

DC_3-8_n28

8

0.2

n28

0.1

DC_3-8_n77

3

0.2

8

0.2

n77

0.5

DC_3-8_n78

3

0.2

8

0.2

n78

0.5

DC_3-18-n77

3

0.2

n77

0.5

DC_3-18-n78

3

0.2

n78

0.5

DC_3-19_n77

3

0.2

n77

0.5

DC_3-19_n78

3

0.2

n78

0.5

DC_3-20_n28

20

0.1

n28

0.1

DC_3-20_n78

3

0.2

n78

0.5

DC_3_n20-n78

3

0.2

n78

0.5

DC_3-21_n77

3

0.3

21

0.5

n77

0.5

DC_3-21_n78

3

0.3

21

0.5

n78

0.5

DC_3-21_n79

3

0.3

21

0.5

28

0.1

n5

0.1

n41

01/0.52

DC_3-28_n78

DC_3_n28-n78

3

0.2

n78

0.5

DC_3-38_n78

3

0.2

38

0.4

n78

0.5

DC_3-41_n28

3

0

41

01/0.52

n28

0

DC_3-41-n77

3

0.2

41

01

0.52

n77

0.5

DC_3-41_n78

3

0.2

41

01

0.52

n78

0.5

DC_3-41-n79

3

0.2

41

01

0.52

DC_3_SUL_n41-n80

n41

0.53

DC_3-42_n77

3

0.2

42

0.5

n77

0.5

DC_3-42_n78

3

0.2

42

0.5

n78

0.5

DC_3-42_n79

3

0.2

42

0.5

DC_3_n77-n79

3

0.2

n77

0.5

DC_3_SUL_n77-n80

3

0.2

n77

0.5

DC_3_SUL_n77-n84

3

0.2

n77

0.5

DC_3_n78-n79

3

0.2

n78

0.5

DC_3-SUL_n78-n80

3

0.2

n78

0.5

DC_3-SUL_n78-n82

3

0.2

n78

0.5

DC_3_SUL_n78-n84

3

0.2

n78

0.5

n71

0.2

DC_5-7_n78

5

0.2

7

0.2

n78

0.52

DC_5_30_n66

30

0.5

n66

0.4

DC_7_n1-n78

7

0.2

n1

0.2

n78

0.5

DC_7-8_n3

8

0.2

DC_7-8_n77

7

0

8

0.2

n77

0.5

DC_7-8_n78

7

0

8

0.2

n78

0.5

DC_7-20_n28

20

0.2

n28

0.2

DC_7-20_n78

n78

0.5

DC_7-28_n78

n78

0.5

DC_7_n28-n78

n78

0.5

DC_7-46_n78

n78

0.5

DC_7_SUL_n78-n80

7

0.2

n78

0.5

DC_8-11_n77

8

0.2

n77

0.5

DC_8-11_n78

8

0.2

n78

0.2

DC_8-20_n78

8

0.2

n78

0.5

DC_8_SUL_n78-n80

8

0.2

n78

0.5

DC_8-SUL_n78-n81

8

0.2

n78

0.2

DC_14-66_n2
DC_14-66-66_n2

66

0.3

n2

0.3

DC_18-28_n77

n77

0.5

DC_18-28_n78

n78

0.5

DC_18-41_n77

n77

0.5

DC_18-41_n78

n78

0.5

42

0.5

n77

0.5

42

0.5

n78

0.5

42

0.5

DC_19-21_n77

n77

0.5

DC_19-21_n78

n78

0.5

DC_19-42_n77

42

0.5

n77

0.5

DC_19-42_n78

42

0.5

n78

0.5

DC_19-42_n79

42

0.5

DC_19_n77-n79

n77

0.5

DC_19_n78-n79

n78

0.5

DC_20_n1-n78

n78

0.5

DC_20_n3-n78

n3

0.2

n78

0.5

DC_20_n28-n75

n28

0.2

DC_20_n28-n78

20

0.2

n28

0.2

n78

0.5

DC_20-38_n78

38

0.4

n78

0.5

DC_20_n75-n78

n78

0.5

DC_20_n76-n78

n78

0.5

DC_20_SUL_n78-n80

n78

0.5

DC_20-SUL_n78-n82

n78

0.5

DC_20-SUL_n78-n83

20

0.2

n78

0.5

DC_21-42_n77

42

0.5

n77

0.5

DC_21-42_n78

42

0.5

n78

0.5

DC_21-42_n79

42

0.5

DC_21_n77-n79

n77

0.5

DC_21_n78-n79

n78

0.5

DC_28-SUL_n78-n83

28

0.2

n78

0.5

n83

0.2

DC_28_n7-n78

n78

0.5

DC_28_n8-n258

28

0.1

n8

0.2

DC_28-41_n77

28

0.2

n77

0.5

DC_28-41_n78

28

0.2

n78

0.5

n79

0.5

DC_28-42_n77

28

0.2

42

0.5

n77

0.5

DC_28-42_n78

28

0.2

42

0.5

n78

0.5

DC_28-42_n79

28

0.2

42

0.5

66

0.4

n5

0.5

DC_41-42_n77

42

0.5

n77

0.5

DC_41-42_n78

42

0.5

n78

0.5

DC_41-42_n79

42

0.5

DC_66-SUL_n78-n86

66

0.2

n78

0.5

NOTE 1: The requirement is applied for UE transmitting on the frequency range of 2545-2690MHz.

NOTE 2: The requirement is applied for UE transmitting on the frequency range of 2496-2545MHz.

NOTE 3: The requirement is applied for UE transmitting on the frequency range of 2515 – 2690 MHz.

NOTE 4: The requirement is applied for UE transmitting on the frequency range of 2496 – 2515 MHz.

NOTE 5: Only applicable for UE supporting inter-band carrier aggregation with uplink in one NR band and without simultaneous Rx/Tx.

7.3B.3.3.3 ΔRIB,c for EN-DC in four bands

Table 7.3B.3.3.3-1: ΔRIB,c due to EN-DC (four bands)

Inter-band EN-DC configuration

E-UTRA or NR Band

ΔRIB,c (dB)

DC_1-3-5_n78

1

0.2

3

0.2

n78

0.5

DC_1-3-7_n28

n28

0.2

DC_1-3-7_n78

DC_1-3-7-7_n78

DC_1-3_n7-n78

1

0.3

3

0.3

7 or n7

0.3

n78

0.5

DC_1-3-8_n77

1

0.2

3

0.2

8

0.2

n77

0.5

DC_1-3-8_n78

1

0.2

3

0.2

8

0.2

n78

0.5

DC_1-3-28_n5

28

0.2

n5

0.2

DC_1-3-18_n77

1

0.2

3

0.2

n77

0.5

DC_1-3-18_n78

1

0.2

3

0.2

n78

0.5

DC_1-3-19_n78

1

0.2

3

0.2

n78

0.5

DC_1-3-20_n28

20

0.2

n28

0.2

DC_1-3-20_n78

1

0.2

3

0.2

n78

0.5

DC_1-3-21_n77

1

0.2

3

0.3

21

0.5

n77

0.5

DC_1-3-21_n78

1

0.2

3

0.3

21

0.5

n78

0.5

DC_1-3-21_n79

3

0.3

21

0.5

DC_1-3-28_n77

1

0.2

3

0.2

28

0.2

n77

0.5

DC_1-3-28_n78

DC_1-3_n28-n78

1

0.2

3

0.2

28 or n28

0.2

n78

0.5

DC_1-3-28_n79

1

0.2

3

0.2

28

0.2

DC_1-3-41_n77

1

0.2

3

0.2

n77

0.5

DC_1-3-41_n78

1

0.2

3

0.2

n78

0.5

DC_1-3-41_n79

41

03/0.54

DC_1-3-42_n77

1

0.2

3

0.2

42

0.5

n77

0.5

DC_1-3-42_n78

1

0.2

3

0.2

42

0.5

n78

0.5

DC_1-3-42_n79

1

0.2

3

0.2

42

0.5

DC_1-3_n77-n79

1

0.2

3

0.2

n77

0.5

DC_1-3_n78-n79

1

0.2

3

0.2

n78

0.5

DC_1-3_SUL_n78-n80

1

0.2

3

0.2

n78

0.5

DC_1-5-7_n78

DC_1-5-7-7_n78

1

0.2

5

0.2

7

0.2

n78

0.5

DC_1-7-20_n28

20

0.2

n28

0.2

DC_1-7-20_n78

1

0.2

7

0.2

20

0.2

n78

0.5

DC_1-7-28_n5

28

0.2

n5

0.2

DC_1-7-28_n78

1

0.2

7

0.2

28

0.2

n78

0.5

DC_1-7_n28-n78

1

0.2

7

0.2

n28

0.2

n78

0.5

DC_1-8-11_n77

1

0.2

8

0.2

n77

0.5

DC_1-8-11_n78

8

0.2

n78

0.5

DC_1-8-20_n78A

8

0.2

n78

0.5

DC_1-18-28_n77

n77

0.5

DC_1-18-28_n78

n78

0.5

DC_1-18-42_n77

42

0.5

n77

0.5

DC_1-18-42_n78

42

0.5

n78

0.5

DC_1-18-42_n79

42

0.5

DC_1-19-42_n77

1

0.2

42

0.5

n77

0.5

DC_1-19-42_n78

42

0.5

n78

0.5

DC_1-19-42_n79

42

0.5

DC_1-19_n77-n79

1

0.3

19

0.3

n77

0.5

DC_1-19_n78-n79

1

0.3

19

0.3

n78

0.5

DC_1-20_n28-n78

20

0.2

n28

0.2

n78

0.5

DC_1-21-42_n77

1

0.2

42

0.5

n77

0.5

DC_1-21-42_n78

42

0.5

n78

0.5

DC_1-21-42_n79

42

0.5

DC_1-21_n77-n79

n77

0.5

DC_1-21_n78-n79

n78

0.5

DC_1-28-42_n77

1

0.2

28

0.2

42

0.5

n77

0.5

DC_1-28-42_n78

28

0.2

42

0.5

n78

0.5

DC_1-28-42_n79

28

0.2

42

0.5

DC_1-41-42_n78

42

0.5

n78

0.5

DC_1-41-42_n79

42

0.5

DC_1-41-42_n79

42

0.5

DC_1-42_n77-n79

1

0.2

42

0.5

n77

0.5

DC_1-42_n78-n79

1

0.2

42

0.5

n78

0.5

DC_2-7-13_n66

2

0.3

7

0.5

n66

0.5

DC_2-7-66_n66

DC_2-7-7-66_n66

2

0.3

7

0.5

66

0.5

n66

DC_2-7-66_n78

DC_2-7-7-66_n78

2

0.6

7

0.5

66

0.6

n78

0.8

DC_2-14-66_n2

DC_2-14-66-66_n2

2

0.3

66

0.3

n2

0.3

DC_2-14-66_n66

DC_2-2-14-66_n66

2

0.3

66

0.3

n66

0.3

DC_2-30-66_n5

2

0.4

30

0.5

66

0.4

DC_2-66-(n)71

2

0.3

66

0.3

DC_3-5-7_n78

DC_3-5-7-7_n78

3

0.2

5

0.2

7

0.2

n78

0.5

DC_3-5-41_n79

41

01/0.52

DC_3-7_n1-n78

3

0.3

7

0.3

n1

0.3

n78

0.5

DC_3-7-7_n78

3

0.2

7

0.2

n78

0.5

DC_3-7-8_n78

3

0.2

7

0.2

8

0.2

n78

0.5

DC_3-7-20_n28

20

0.2

n28

0.1

DC_3-7-20_n78

3

0.2

7

0.2

n78

0.5

DC_3-7-28_n78

DC_3-7_n28-n78

3

0.2

7

0.2

28 or n28

0.2

n78

0.5

DC_3-7_SUL_n78-n80

7

0.2

3

0.2

n78

0.5

DC_3-8-20_n78A

3

0.2

8

0.2

n78

0.5

DC_3-8_SUL_n78-n80

3

0.2

8

0.2

n78

0.5

DC_3-18-42_n77

42

0.5

n77

0.5

DC_3-18-42_n78

42

0.5

n78

0.5

DC_3-18-42_n79

3

0.2

42

0.5

DC_3-19-21_n77

3

0.3

21

0.5

n77

0.5

DC_3-19-21_n78

3

0.3

21

0.5

n78

0.5

DC_3-19-21_n79

3

0.3

21

0.5

DC_3-19-42_n77

3

0.2

42

0.5

n77

0.5

DC_3-19-42_n78

3

0.2

42

0.5

n78

0.5

DC_3-19-42_n79

3

0.2

42

0.5

DC_3-19_n77-n79

3

0.2

n77

0.5

DC_3-19_n78-n79

3

0.2

n78

0.5

DC_3-20_n28-n78

3

0.2

20

0.2

n28

0.2

n78

0.5

DC_3_20_SUL_n78-n80

3

0.2

n78

0.5

DC_3-21-42_n77

3

0.3

21

0.5

42

0.5

n77

0.5

DC_3-21-42_n78

3

0.3

21

0.5

42

0.5

n78

0.5

DC_3-21-42_n79

3

0.3

21

0.5

42

0.5

DC_3-21_n77-n79

3

0.3

21

0.5

n77

0.5

DC_3-21_n78-n79

3

0.3

21

0.5

n78

0.5

DC_3-28-42_n77

3

0.2

28

0.2

42

0.5

n77

0.5

DC_3-28-42_n78

3

0.2

28

0.2

42

0.5

n78

0.5

DC_3-28-42_n79

3

0.2

28

0.2

42

0.5

DC_3-41-42_n77

3

0.5

41

01/0.52

42

0.5

n77

0.5

DC_3-41-42_n78

3

0.5

41

01/0.52

42

0.5

n78

0.5

DC_3-41-42_n79

3

0.5

41

01/0.52

42

0.5

DC_3-42_n77-n79

3

0.2

42

0.5

n77

0.5

DC_3-42_n78-n79

3

0.2

42

0.5

n78

0.5

DC_5-7-7_n78

5

0.2

7

0.2

n78

0.5

DC_7-20_n28-n78

20

0.2

n28

0.2

n78

0.5

DC_12-30-66_n260

12

0.5

30

0.5

66

0.4

DC_19-21-42_n77

42

0.5

n77

0.5

DC_19-21-42_n78

42

0.5

n78

0.5

DC_19-21-42_n79

42

0.5

DC_19-21_n77-n79

n77

0.5

DC_19-21_n78-n79

n78

0.5

DC_19-42_n77-n79

42

0.5

n77

0.5

DC_19-42_n78-n79

42

0.5

n78

0.5

DC_21-28-42_n77

28

0.2

42

0.5

n77

0.5

DC_21-28-42_n78

28

0.2

42

0.5

n78

0.5

DC_21-28-42_n79

28

0.2

42

0.5

DC_21-42_n77-n79

42

0.5

n77

0.5

DC_21-42_n78-n79

42

0.5

n78

0.5

NOTE 1: The requirement is applied for UE transmitting on the frequency range of 2545 – 2690 MHz.

NOTE 2: The requirement is applied for UE transmitting on the frequency range of 2496 – 2545 MHz.

NOTE 3: The requirement is applied for UE transmitting on the frequency range of 2515 – 2690 MHz.

NOTE 4: The requirement is applied for UE transmitting on the frequency range of 2496 – 2515 MHz.

7.3B.3.3.4 ΔRIB,c for EN-DC in five bands

Table 7.3B.3.3.4-1: ΔRIB,c due to EN-DC (five bands)

Inter-band EN-DC configuration

E-UTRA or NR Band

ΔRIB,c (dB)

DC_1-3-5-7_n78,

DC_1-3-5-7-7_n78

1

0.2

3

0.2

5

0.2

7

0.2

n78

0.5

DC_1-3-5-41_n79

41

01

0.52

DC_1-3-7-20_n28

20

0.2

n28

0.2

DC_1-3-7-20_n78

1

0.2

3

0.2

7

0.2

n78

0.5

DC_1-3-7-28_n78

1

0.2

3

0.2

7

0.2

28

0.2

n78

0.5

DC_1-3-7_n28-n78

1

0.2

3

0.2

7

0.2

n28

0.2

n78

0.5

DC_1-3-18-42_n77

1

0.2

3

0.2

42

0.5

n77

0.5

DC_1-3-18-42_n78

1

0.2

3

0.2

42

0.5

n78

0.5

DC_1-3-18-42_n79

1

0.2

3

0.2

42

0.5

DC_1-3-19-21-n77

1

0.2

3

0.3

21

0.5

n77

0.5

DC_1-3-19-21_n78

1

0.2

3

0.3

21

0.5

n78

0.5

DC_1-3-19-21_n79

3

0.3

21

0.5

DC_1-3-19-42_n77

1

0.2

3

0.2

42

0.5

n77

0.5

DC_1-3-19-42_n79

1

0.2

3

0.2

42

0.5

DC_1-3-20_n28-n78

1

0.2

3

0.2

20

0.2

n28

0.2

n78

0.5

DC_1-3-21-42_n77

1

0.2

3

0.3

21

0.5

42

0.5

n77

0.2

DC_1-3-21-42_n78

1

0.2

3

0.3

21

0.5

42

0.5

n78

0.2

DC_1-3-21-42_n79

1

0.2

3

0.3

21

0.5

42

0.5

n79

0.0

DC_1-3-21_n77-n79

1

0.2

3

0.3

21

0.5

n77

0.5

DC_1-3-21_n78-n79

1

0.2

3

0.3

21

0.5

n78

0.5

DC_1-3-28-42_n77

1

0.2

3

0.2

28

0.2

42

0.5

n77

0.5

DC_1-3-28-42_n78

1

0.2

3

0.2

28

0.2

42

0.5

n78

0.5

DC_1-3-28-42_n79

1

0.2

3

0.2

28

0.2

42

0.5

DC_1-3-41-42_n77

1

0.2

3

0.2

42

0.5

n77

0.5

DC_1-3-41-42_n78

1

0.2

3

0.2

42

0.5

n78

0.5

DC_1-3-41-42_n79

1

0.2

3

0.2

42

0.5

DC_1-7-20_n28-n78

1

0.2

7

0.2

20

0.2

n28

0.2

n78

0.5

DC_1-19-21-42_n77

1

0.2

42

0.5

n77

0.5

DC_1-19-21-42_n78

42

0.5

n78

0.5

DC_1-19-21-42_n79

42

0.5

DC_1-19-42_n77-n79

1

0.2

42

0.5

n77

0.5

DC_1-19-42_n78-n79

42

0.5

n78

0.5

DC_1-21-28-42_n77

1

0.2

28

0.2

42

0.5

n77

0.5

DC_1-21-28-42_n78

28

0.2

42

0.5

n78

0.5

DC_1-21-28-42_n79

28

0.2

42

0.5

DC_1-21-42_n77-n79

1

0.2

21

0.2

42

0.5

n77

0.5

DC_1-21-42_n78-n79

21

0.2

42

0.5

n78

0.5

DC_3-7-20_n28-n78

3

0.2

7

0.2

20

0.2

n28

0.2

DC_3-19-21-42_n77

3

0.3

21

0.5

42

0.5

n77

0.5

DC_3-19-21-42_n78

3

0.3

21

0.5

42

0.5

n78

0.5

DC_3-19-21-42_n79

3

0.3

21

0.5

42

0.5

DC_19-21-42_n77-n79

42

0.5

n77

0.5

DC_19-21-42_n78-n79

42

0.5

n78

0.5

NOTE 1: The requirement is applied for UE transmitting on the frequency range of 2545 – 2690 MHz.

NOTE 2: The requirement is applied for UE transmitting on the frequency range of 2496 – 2545 MHz.

7.3B.3.3.5 ΔRIB,c for EN-DC six bands

Table 7.3B.3.3.5-1: ΔRIB,c due to EN-DC (six bands)

Inter-band EN-DC configuration

E-UTRA or NR Band

ΔRIB,c (dB)

DC_1-3-7-20_n28-n78

1

0.2

3

0.2

7

0.2

20

0.2

n28

0.2

n78

0.5

7.3B.3.3a ΔRIB,c for Inter-band NE-DC within FR1

Unless ΔRIB,c is specified in this clause, the value of ΔRIB,c for the correspondingly specified EN-DC configuration in clause 7.3B.3.3 is applicable.

7.3B.3.4 Reference sensitivity for ΔRIB,c Inter-band EN-DC including FR2

The ΔRIB,c for NR FR2 band of inter-band CA defined in tables 5.5B.5.1-1 to 5.5B.5.5-1 is set to zero.

7.3B.3.5 Reference sensitivity for ΔRIB,c Inter-band EN-DC including both FR1 and FR2

The ΔRIB,c for NR FR2 band of inter-band CA defined in tables 5.5B.6.2-1 to 5.5B.6.5-1 is set to zero and ΔRIB,c for constituent E-UTRA and FR1 NR bands is the same as those for the corresponding inter band EN-DC configuration without the FR2 bands specified in 7.3B.3.3.