6.5B.3 Spurious emissions for EN-DC

38.521-33GPPNRPart 3: Range 1 and Range 2 Interworking operation with other radiosRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification

Spurious emissions are emissions which are caused by unwanted transmitter effects such as harmonics emission, parasitic emissions, intermodulation products and frequency conversion products, but exclude out of band emissions. The spurious emission limits are specified in terms of general requirements in line with SM.329 [3] and NR operating band requirement to address UE co-existence.

To improve measurement accuracy, sensitivity and efficiency, the resolution bandwidth may be smaller than the measurement bandwidth. When the resolution bandwidth is smaller than the measurement bandwidth, the result should be integrated over the measurement bandwidth in order to obtain the equivalent noise bandwidth of the measurement bandwidth.

6.5B.3.1 Spurious Emissions for intra-band contiguous EN-DC

6.5B.3.1.1 General spurious emissions for intra-band contiguous EN-DC

6.5B.3.1.1.1 Test purpose

To verify that UE transmitter does not cause unacceptable interference to other channels or other systems in terms of transmitter spurious emissions.

6.5B.3.1.1.2 Test applicability

This test case applies to all types of E-UTRA UE release 15 and forward, supporting intra-band contiguous EN-DC.

6.5B.3.1.1.3 Minimum conformance requirements

The general spurious emissions requirements specified in clause 6.6.3.1 of TS 36.101 [5] and clause 6.5.3.1 of TS 38.101-1 [2] apply beyond any frequencies for which the out-of-band emissions requirements in clause 6.5B.2.1 of TS 38.101-3 [4] apply.

The normative reference for this requirement is TS 38.101-3 [4] clause 6.5B.3.1.1.

No exception requirements applicable to NR or E-UTRA. LTE anchor agnostic approach is applied.

6.5B.3.1.1.4 Test description

Same test description as in clause 6.5.3.1.4 in TS 38.521-1 [8] for the NR carrier with the following exceptions:

Table 6.5B.3.1.1.4-1: Test Configuration Table

Initial Conditions

Test Frequencies as specified in TS 38.508-1 [6] clause 4.3.1 for different EN-DC bandwidth classes

Low range, Mid range, High range

Test EN-DC bandwidth combination as specified in Table 5.3B.1.2-1 across bandwidth combination sets supported by the UE

Lowest NRB_agg, Highest NRB_agg (NOTE 1)

NOTE 1: If the UE supports multiple CC Combinations in the EN-DC Configuration with the same NRB_agg, only the combination with the highest NRB_SCG is tested for Lowest NRB_agg and Highest NRB_agg, respectively.

The initial test configurations for E-UTRA band consist of environmental conditions, test frequencies, and channel bandwidths are specified in Table 4.6-1 except for the parameters specified in Table 6.5B.3.1.1.4-1.

For Initial conditions as in clause 6.5.3.1.4 in TS 38.521-1 [8], the following steps will be added to configure E-UTRA component:

2.1 The parameter settings for the E-UTRA cell are set up according to TS 36.508 [11] clause 4.4.3 with E-UTRA channel bandwidth and test frequencies defined in Table 6.5B.3.1.1.4-1.

3.1. The E-UTRA downlink signal level, uplink signal level are set according to Table 4.6-1 and propagation conditions are set according to Annex B.0 of TS 36.521-1 [10].

4.1. The UL Reference Measurement channels are set according to Table 6.5B.3.1.1.4-1.

Step 6 of Initial conditions as in clause 6.5.3.1.4 in TS 38.521-1 [8] is replaced by the following two steps:

6. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508-1 [6] clause 4.5.

7. On the E-UTRA carrier, disable periodic and aperiodic CQI reports, disable SRS, set TimeAlignmentTimerDedicated IE to infinity and disable downlink and uplink scheduling, all as per Table 4.6-1 under clause 4.6.

Same test procedure as in clause 6.5.3.1.4 in TS 38.521-1 [8].

6.5B.3.1.1.5 Test Requirement

The measured average power of spurious emission, derived in step 5, shall not exceed the described value in Table 6.5B.3.1.1.5-1.

Unless otherwise stated, the spurious emission limits apply for the frequency ranges that are more than ΔfOOB (MHz) from the edge of the channel bandwidth shown in Table 6.5.3.1.3-1 of TS 38.521-1 [8] for NR carrier, and Table 6.6.3.1.3-1 of TS 36.521-1[10] for E-UTRA carrier.

NOTE: For measurement conditions at the edge of each frequency range, the lowest frequency of the measurement position in each frequency range should be set at the lowest boundary of the frequency range plus MBW/2. The highest frequency of the measurement position in each frequency range should be set at the highest boundary of the frequency range minus MBW/2. MBW denotes the measurement bandwidth defined for the protected band.

Table 6.5B.3.1.1.5-1: General spurious emissions test requirements

Frequency Range

Maximum Level

Measurement bandwidth

NOTE

9 kHz ≤ f < 150 kHz

-36 dBm

1 kHz

150 kHz ≤ f < 30 MHz

-36 dBm

10 kHz

30 MHz ≤ f < 1000 MHz

-36 dBm

100 kHz

1 GHz ≤ f < 12.75 GHz

-30 dBm

1 MHz

4

-25 dBm

1 MHz

3

12.75 GHz ≤ f < 5th harmonic of the upper frequency edge of the UL operating band in GHz

-30 dBm

1 MHz

1

12.75 GHz < f < 26 GHz

-30 dBm

1 MHz

2

NOTE 1: Applies for Band that the upper frequency edge of the UL Band more than 2.69 GHz.

NOTE 2: Applies for Band that the upper frequency edge of the UL Band more than 5.2 GHz.

NOTE 3: Applies for Band n41, CA configurations including Band n41, and EN-DC configurations that include n41 specified in clause 5.2B of TS 36.101 [5] when NS_04 is signalled.

NOTE 4: Does not apply for Band n41, CA configurations including Band n41, and EN-DC configurations that include n41 specified in subclause 5.2B of TS 38.101-3 [4] when NS_04 is signalled.

6.5B.3.1.2 Spurious emission band UE co-existence for intra-band contiguous EN-DC

6.5B.3.1.2.1 Test purpose

To verify that UE transmitter does not cause unacceptable interference to other channels or other systems in terms of transmitter spurious emissions for band UE co-existence for intra-band contiguous EN-DC.

6.5B.3.1.2.2 Test applicability

This test case applies to all types of NR UE release 15 and forward supporting intra-band contiguous EN-DC.

6.5B.3.1.2.3 Minimum conformance requirements

This clause specifies the requirements for the specified EN-DC configurations for coexistence with protected bands.

The requirements in Table 6.5B.3.1.2.3-1 apply on each component carrier with all component carriers are active.

Table 6.5B.3.1.2.3-1: Requirements for intra band contiguous EN-DC

EN-DC Configuration

Spurious emission

Protected band

Frequency range (MHz)

Maximum Level (dBm)

MBW (MHz)

NOTE

DC_(n)71

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 30, 48, 66

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25, 41, 70

NR Band n77 5

FDL_low

FDL_high

-50

1

2

E-UTRA Band 29

FDL_low

FDL_high

-38

1

3

E-UTRA Band 71

FDL_low

FDL_high

-50

1

3

DC_(n)41

E-UTRA Band 1, 2, 3, 4, 5, 8, 10, 11, 12, 13, 14, 17, 18, 19, 21, 24, 25, 26, 27, 28, 29, 30, 34, 39, 42, 44, 45, 48, 50, 51, 66, 70, 71, 73, 74

NR Band n77, n78

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

4

NR Band n79

FDL_low

FDL_high

-50

1

2

NOTE 1: FDL_low and FDL_high refer to each frequency band specified in Table 5.5-1 in TS 36.101 [5] or in Table 5.2-1 in TS 38.101-1 [2].

NOTE 2: As exceptions, measurements with a level up to the applicable requirements defined in Table 6.6.3.1-2 in TS 36.101 [5] and Table 6.5.3.1-2 in TS 38.101-1 [2] are permitted for each assigned carrier used in the measurement due to 2nd, 3rd, 4th or 5th harmonic spurious emissions. Due to spreading of the harmonic emission the exception is also allowed for the first 1 MHz frequency range immediately outside the harmonic emission on both sides of the harmonic emission. This results in an overall exception interval centred at the harmonic emission of (2MHz + N x LCRB x 180kHz), where N is 2, 3, 4, 5 for the 2nd, 3rd, 4th or 5th harmonic respectively. The exception is allowed if the measurement bandwidth (MBW) totally or partially overlaps the overall exception interval.

NOTE 3: These requirements also apply for the frequency ranges that are less than F OOB (MHz) in Table 6.6.3.1-1, Table 6.6.3.1A-1 in TS 36.101 [5] or in Table 6.5.3.1-1 in TS 38.101-1 [2] from the edge of the channel bandwidth.

NOTE 4: Applicable when co-existence with PHS system operating in 1884.5 – 1915.7 MHz.

NOTE 5: Only applies to NR UE release 16 and forward supporting intra-band contiguous EN-DC.

NOTE: To simplify the above Table, E-UTRA band numbers are listed for bands which are specified only for E-UTRA operation or both E-UTRA and NR operation. NR band numbers are listed for bands which are specified only for NR operation.

The normative reference for this requirement is TS 38.101-3 [4] clause 6.5B.3.1.2.

Exception requirements for both NR and E-UTRA are defined for this test and therefore LTE anchor agnostic approach is not applied. E-UTRA test point analysis is included, and E-UTRA measurements are performed.

6.5B.3.1.2.4 Test description

6.5B.3.1.2.4.1 Initial conditions

Initial conditions are a set of test configurations the UE needs to be tested in and the steps for the SS to take with the UE to reach the correct measurement state.

The initial test configurations consist of environmental conditions, test frequencies and channel bandwidths based on EN-DC operating bands specified in clause 5.5B.2, and the channel bandwidth combination for E-UTRA and NR component carriers shall follow the value specified in Table 5.3B.1.2-1. All these configurations shall be tested with applicable test parameters for each EN-DC configuration specified in clause 5.3B.1.2 and are shown in Table 6.5B.3.1.2.4.1-1. The details of the uplink reference measurement channels (RMCs) are specified in TS 36.521-1 [10] Annexe A, clause A.2.3 for E-UTRA RMC for TDD, TS 36.521-1 [10] Annex A, clause A.2.2 for E-UTRA RMC for FDD, and TS 38.521-1 [8] Annex A, clause A.2 for NR RMC. Configurations of PDSCH and PDCCH before measurement are specified in TS 36.521-1 [10] Annex C.2 and in TS 38.521-1 [8] Annex C.2 for E-UTRA CG and NR CG respectively.

Table 6.5B.3.1.2.4.1-1: Test configuration table

Initial Conditions

Test Environment

as specified in TS 38.508-1 [6] clause 4.1

Normal

Test Frequencies

as specified in TS 38.508-1 [6] clause 4.3.1

Low range, High range

Test EN-DC bandwidth combination as specified in Table 5.3B.1.2-1

Lowest and Highest NRB_agg

(NOTE 3)

Test SCS for the NR cell as specified in TS 38.521-1 [8] Table 5.3.5-1

Lowest SCS per Channel Bandwidth

Test Parameters

Test ID

Downlink Configuration

EN-DC Uplink Configuration

E-UTRA Cell

NR Cell

Modulation

RB allocation

(NOTE 2)

Modulation

RB allocation (NOTE 1)

1

N/A for Spurious emission.

QPSK

Outer_1RB_Left

CP-OFDM QPSK

Edge_1RB_Right

2

QPSK

Outer_Full

CP-OFDM QPSK

Outer_Full

NOTE 1: The specific configuration of each RB allocation is defined in Table 6.1-1 in TS 38.521-1 [8].

NOTE 2: Outer_Full defined as the transmission bandwidth configuration NRB per channel bandwidth for the E-UTRA component as indicated in TS 36.521-1 [10] Table 5.4.2-1. Outer_1RB_Left defined as 1 RB allocated at the left edge of the E-UTRA component. Outer_1RB_Right defined as 1 RB allocated at the right edge of the E-UTRA component.

NOTE 3: If the UE supports multiple CC Combinations in the EN-DC Configuration with the same aggregated channel BW, only the combination with the highest NR BW is tested.

NOTE 4: The test configuration applies to intra-band contiguous EN-DC indicating support of dual simultaneous UL as defined in clause 5.5B.2.

1. Connect the SS to the UE antenna connectors as shown in TS 38.508-1 [6] Annex A, Figure A.3.1.1.1 for TE diagram and clause A.3.2.1 for UE diagram.

2. The parameter settings for the E-UTRA cell are set up according to TS 36.508 [11] clause 4.4.3, and the parameter settings for the NR cell are set up according to TS 38.508-1 [6] clause 4.4.3.

3. E-UTRA downlink signals are initially set up according to Annex C0, C.1 and C.3.0, and uplink signals according to Annex H.1 and H.3.0 of TS 36.521-1 [10].

4. NR downlink signals are initially set up according to Annex C.0, C.1 and C.2, and uplink signals according to Annex G.0, G.1, G.2, G.3.0 of TS 38.521-1 [8].

5. The UL Reference Measurement channels are set up according to TS 36.521-1 [10] Annex A.2 and TS 38.521-1 [8] Annex A.2 for E-UTRA CG and NR CG, respectively.

6. Propagation conditions are set according to TS 36.521-1 [10] Annex B.0 and TS 38.521-1 [8] Annex B.0 for E-UTRA CG and NR CG, respectively.

7. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508-1 [6] clause 4.5. Message contents are defined in clause 6.5B.3.1.2.4.3.

8. For the case of testing overlapping E-UTRA and NR UL transmission scenario when both bands are TDD, ensure E-UTRA UL transmission overlaps with NR UL transmission in time by giving SCG a delay of 3 E-UTRA subframes, or by giving MCG a delay of 2 subframes.

6.5B.3.1.2.4.2 Test Procedure

1. E-UTRA SS sends uplink scheduling information for each UL HARQ process via PDCCH DCI format 0 for C_RNTI to schedule the UL RMC according to Table 6.5B.3.1.2.4.1-1. Since the UE has no payload data to send, the UE transmits uplink MAC padding bits on the UL RMC.

2. NR SS sends uplink scheduling information for each UL HARQ process via PDCCH DCI format 0_1 for C_RNTI to schedule the UL RMC according to Table 6.5B.3.1.2.4.1-1. Since the UE has no payload data to send, the UE transmits uplink MAC padding bits on the UL RMC.

3. Both NR and E-UTRA SS send continuously uplink power control "up" commands in the uplink scheduling information to the UE until the UE transmits at PUMAX level; allow at least 200 ms starting from the first TPC command in this step for the UE to reach PUMAX level.

4. Measure the power of the transmitted signal with a measurement filter of bandwidths according to Table 6.5B.3.1.2.3-1. The centre frequency of the filter shall be stepped in contiguous steps according to Table 6.5B.3.1.2.3-1. The measured power shall be verified for each step. The measurement period shall capture the active time slots.

In addition to test configuration and test procedure above, EN-DC only capable UEs and UEs not supporting NR/5GC mode in the tested band need to be tested according to test description as in clause 6.5.3.2.4 in TS 38.521-1 [8] for the NR carrier with the following exceptions:

LTE anchor agnostic approach as specified in section 4.6.

6.5B.3.1.2.4.3 Message Contents

Message contents are according to TS 36.508 [11] clause 4.6 and TS 38.508-1 [6] clause 4.6.1 with the following exceptions:

Table 6.5B.3.1.2.4.3-1: RRCConnectionReconfiguration: nr-Config-r15

Derivation Path: TS 36.508 [11], Table 4.6.1-8

Information Element

Value/remark

Comment

Condition

p-MaxEUTRA-r15

23

Power Class 2 UE

20

Power Class 3 UE

Table 6.5B.3.1.2.4.3-2: PhysicalCellGroupConfig

Derivation Path: TS 38.508-1 [6] Table 4.6.3-106

Information Element

Value/remark

Comment

Condition

p-NR-FR1

23

Power Class 2 UE

20

Power Class 3 UE

Table 6.5B.3.1.2.4.3-3: SystemInfomationBlockType1: tdd-Config if operating on TDD band

Derivation Path: TS 36.508 [11], Table 4.6.3-23

Information Element

Value/remark

Comment

Condition

TDD-Config-DEFAULT ::= SEQUENCE {

Operating on TDD band

subframeAssignment

sa2

specialSubframePatterns

ssp7

}

6.5B.3.1.2.5 Test Requirement

Test requirements for Spurious Emissions UE Co-existence for intra-band contiguous EN-DC are the same as the minimum requirements described in clause 6.5B.3.1.2.3 minimum requirements and are not repeated in this clause.

For EN-DC only capable devices, in addition to Table 6.5B.3.1.2.3-1, test requirements for NR carrier are the same as Table 6.5.3.2.5-1 in TS 38.521-1 [8].

6.5B.3.2 Spurious Emissions for intra-band non-contiguous EN-DC

6.5B.3.2.1 General spurious emissions for Intra-band non-contiguous EN-DC

6.5B.3.2.1.1 Test purpose

To verify that UE transmitter does not cause unacceptable interference to other channels or other systems in terms of transmitter spurious emissions.

6.5B.3.2.1.2 Test applicability

This test case applies to all types of E-UTRA UE release 15 and forward supporting intra-band non-contiguous EN-DC.

6.5B.3.2.1.3 Minimum conformance requirements

The general spurious emissions requirements specified in clause 6.6.3.1 of TS 36.521-1 [10] and clause 6.5.3.1 of TS 38.521-1 [8] apply beyond any frequencies for which the out-of-band emissions requirements in clause 6.5B.2.2 of TS 38.101-3 [4] apply. If for some frequency an individual CC spurious emission requirement overlaps with the general spectrum emission mask or the bandwidth of another CC then it does not apply.

The normative reference for this requirement is TS 38.101-3 [4] clause 6.5B.3.2.1.

No exception requirements applicable to NR or E-UTRA. LTE anchor agnostic approach is applied.

6.5B.3.2.1.4 Test description

Same test description as in clause 6.5.3.1.4 in TS 38.521-1 [8] for the NR carrier with the following exceptions:

Table 6.5B.3.2.1.4-1: Test Configuration Table

Initial Conditions

Test Frequencies as specified in TS 38.508-1 [6] clause 4.3.1 for different EN-DC bandwidth classes

Low with maxWgap

High with maxWgap

Test EN-DC bandwidth combination as specified in Table 5.3B.1.2-1 across bandwidth combination sets supported by the UE

Lowest NRB_agg, Highest NRB_agg (NOTE 1)

NOTE 1: If the UE supports multiple CC Combinations in the EN-DC Configuration with the same NRB_agg, only the combination with the highest NRB_SCG is tested for Lowest NRB_agg and Highest NRB_agg, respectively.

The initial test configurations for E-UTRA band consist of environmental conditions, test frequencies, and channel bandwidths are specified in Table 4.6-1 except for the parameters specified in Table 6.5B.3.2.1.4-1.

For Initial conditions as in clause 6.5.3.1.4 in TS 38.521-1 [8], the following steps will be added to configure E-UTRA component:

2.1. The parameter settings for the E-UTRA cell are set up according to TS 36.508 [11] clause 4.4.3 with E-UTRA channel bandwidth and test frequencies defined in Table 6.5B.3.2.1.4-1.

3.1. The E-UTRA downlink signal level, uplink signal level are set according to Table 4.6-1 and propagation conditions are set according to Annex B.0 of TS 36.521-1 [10].

Step 6 of Initial conditions as in clause 6.5.3.1.4.1 in TS 38.521-1 [8] is replaced by the following two steps:

6. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508-1 [6] clause 4.5.

7. On the E-UTRA carrier, disable periodic and aperiodic CQI reports, disable SRS, set TimeAlignmentTimerDedicated IE to infinity and disable downlink and uplink scheduling, all as per Table 4.6-1 under clause 4.6.

Same test procedure as in clause 6.5.3.1.4.2 in TS 38.521-1 [8].

6.5B.3.2.1.5 Test Requirement

Same test requirement as in clause 6.5B.3.1.1.5.

6.5B.3.2.2 Spurious emission band UE co-existence for intra-band non-contiguous EN-DC

6.5B.3.2.2.1 Test purpose

To verify that UE transmitter does not cause unacceptable interference to other channels or other systems in terms of transmitter spurious emissions for band UE co-existence for intra-band non-contiguous EN-DC.

6.5B.3.2.2.2 Test applicability

This test case applies to all types of E-UTRA UE release 15 and forward supporting intra-band non-contiguous EN-DC.

6.5B.3.2.2.3 Minimum conformance requirements

This clause specifies the requirements for the specified EN-DC configurations for co-existence with protected bands.

The requirements in Table 6.5B.3.2.2.3-1 apply with all component carriers are active.

Table 6.5B.3.2.2.3-1: Requirements for intra-band non-contiguous EN-DC

EN-DC Configuration

Spurious emission

Protected band

Frequency range (MHz)

Maximum Level (dBm)

MBW (MHz)

NOTE

DC_41A_n41A

E-UTRA Band 1, 2, 3, 4, 5, 8, 10, 11, 12, 13, 14, 17, 18, 19, 21, 24, 25, 26, 27, 28, 29, 34, 39, 42, 44, 45, 48, 50, 51, 66, 70, 71, 73, 74

NR Band n77, n78 and n79

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

E-UTRA Band 30, 40

FDL_low

FDL_high

-40

1

NOTE 1: FDL_low and FDL_high refer to each E-UTRA frequency band specified in Table 5.5-1 in TS 36.101 [5] or in Table 5.2-1 in TS 38.101-1 [2].

NOTE 2: As exceptions, measurements with a level up to the applicable requirements defined in Table 6.6.3.1-2 in TS 36.101 [5] and Table 6.5.3.1-2 in TS 38.101-1 [2] are permitted for each assigned carrier used in the measurement due to 2nd, 3rd, 4th, or 5th harmonic spurious emissions. Due to spreading of the harmonic emission the exception is also allowed for the first 1 MHz frequency range immediately outside the harmonic emission on both sides of the harmonic emission. This results in an overall exception interval centred at the harmonic emission of (2MHz + N x LCRB x 180kHz), where N is 2, 3, 4, 5 for the 2nd, 3rd, 4th or 5th harmonic respectively. The exception is allowed if the measurement bandwidth (MBW) totally or partially overlaps the overall exception interval.

NOTE 3: Applicable when co-existence with PHS system operating in 1884.5 – 1915.7 MHz.

NOTE: To simplify the above Table, E-UTRA band numbers are listed for bands which are specified only for EUTRA operation or both E-UTRA and NR operation. NR band numbers are listed for bands which are specified only for NR operation.

The normative reference for this requirement is TS 38.101-3 [4] clause 6.5B.3.2.2.

Exception requirements are applicable for NR but not for E-UTRA within this test. LTE anchor agnostic approach is not applied. E-UTRA configuration is included.

6.5B.3.2.2.4 Test description

6.5B.3.2.2.4.1 Initial conditions

Initial conditions are a set of test configurations the UE needs to be tested in and the steps for the SS to take with the UE to reach the correct measurement state.

The initial test configurations consist of environmental conditions, test frequencies and channel bandwidths based on EN-DC operating bands specified in clause 5.5B.3, and the channel bandwidth combination for E-UTRA and NR component carriers shall follow the value specified in Table 5.3B.1.3-1. All these configurations shall be tested with applicable test parameters for each EN-DC configuration specified in clause 5.3B.1.3 and are shown in Table 6.5B.3.2.2.4.1-1. The details of the uplink reference measurement channels (RMCs) are specified in TS 36.521-1 [10] Annexe A, clause A.2.3 for E-UTRA RMC for TDD, TS 36.521-1 [10] Annex A, clause A.2.2 for E-UTRA RMC for FDD, and TS 38.521-1 [8] Annex A, clause A.2 for NR RMC. Configurations of PDSCH and PDCCH before measurement are specified in TS 36.521-1 [10] Annex C.2 and in TS 38.521-1 [8] Annex C.2 for E-UTRA CG and NR CG respectively.

Table 6.5B.3.2.2.4.1-1: Test configuration table

Initial Conditions

Test Environment

as specified in TS 38.508-1 [6] clause 4.1

Normal

Test Frequencies

as specified in TS 38.508-1 [6] clause 4.3.1

Low with maxWgap

High with maxWgap

Test EN-DC bandwidth combination as specified in Table 5.3B.1.3-1

Lowest and Highest NRB_agg

(NOTE 3)

Test SCS for the NR cell as specified in TS 38.521-1 [8] Table 5.3.5-1

Lowest SCS per Channel Bandwidth

Test Parameters

Test ID

Downlink Configuration

EN-DC Uplink Configuration

E-UTRA Cell

NR Cell

Modulation

RB allocation

(NOTE 2)

Modulation

RB allocation (NOTE 1)

1

N/A for Spurious emission.

QPSK

Outer_1RB_Left

CP-OFDM QPSK

Edge_1RB_Right

2

QPSK

Outer_Full

CP-OFDM QPSK

Outer_Full

NOTE 1: The specific configuration of each RB allocation is defined in Table 6.1-1 in TS 38.521-1 [8].

NOTE 2: Outer_Full defined as the transmission bandwidth configuration NRB per channel bandwidth for the E-UTRA component as indicated in TS 36.521-1 [10] Table 5.4.2-1. Outer_1RB_Left defined as 1 RB allocated at the left edge of the E-UTRA component. Outer_1RB_Right defined as 1 RB allocated at the right edge of the E-UTRA component.

NOTE 3: If the UE supports multiple CC Combinations in the EN-DC Configuration with the same aggregated channel BW, only the combination with the highest NR BW is tested.

NOTE 4: The test configuration applies to intra-band non-contiguous EN-DC indicating support of dual simultaneous UL as defined in clause 5.5B.3.

1. Connect the SS to the UE antenna connectors as shown in TS 38.508-1 [6] Annex A, Figure A.3.1.1.1 for SS diagram and clause A.3.2.1 for UE diagram.

2. The parameter settings for the cell are set up according to TS 38.508-1 [6] clause 4.4.3.

3. E-UTRA downlink signals are initially set up according to Annex C.0, C.1 and C.3.0, and uplink signals according to Annex H.1 and H.3.0 of TS 36.521-1 [10].

4. NR downlink signals are initially set up according to Annex C.0, C.1 and C.2, and uplink signals according to Annex G.0, G.1, G.2, G.3.0 of TS 38.521-1 [8].

5. The UL Reference Measurement channels are set according to TS 36.521-1 [10] Annex A.2 and TS 38.521-1 [8] Annex A.2 for E-UTRA CG and NR CG respectively.

6. Propagation conditions are set according to TS 36.521-1 [10] Annex B and TS 38.521-1 [8] Annex B for E-UTRA link and NR link respectively.

7. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508-1 [6] clause 4.5. Message contents are defined in clause 6.5B.3.2.2.4.3.

8. For the case of testing overlapping E-UTRA and NR UL transmission scenario when both bands are TDD, ensure E-UTRA UL transmission overlaps with NR UL transmission in time by giving SCG a delay of 3 E-UTRA subframes, or by giving MCG a delay of 2 subframes.

6.5B.3.2.2.4.2 Test Procedure

1. E-UTRA SS sends uplink scheduling information for each UL HARQ process via PDCCH DCI format 0 for C_RNTI to schedule the UL RMC according to Table 6.5B.3.2.2.4.1-1. Since the UE has no payload data to send, the UE transmits uplink MAC padding bits on the UL RMC.

2. NR SS sends uplink scheduling information for each UL HARQ process via PDCCH DCI format 0_1 for C_RNTI to schedule the UL RMC according to Table 6.5B.3.2.2.4.1-1. Since the UE has no payload data to send, the UE transmits uplink MAC padding bits on the UL RMC.

3. Send continuously uplink power control "up" commands to the UE for both NR and E-UTRA carriers until the UE transmits at its PUMAX level; allow at least 200 ms starting from the first TPC command in this step for the UE to reach PUMAX level.

4. Measure the power of the transmitted signal with a measurement filter of bandwidths according to Table 6.5B.3.2.2.3-1. The centre frequency of the filter shall be stepped in contiguous steps according to the same table. The measured power shall be verified for each step. The measurement period shall capture the active time slots.

In addition to test configuration and test procedure above, EN-DC only capable UEs and UEs not supporting NR/5GC mode in the tested band need to be tested according to test description as in clause 6.5.3.2.4 in TS 38.521-1 [8] for the NR carrier with the following exceptions:

LTE anchor agnostic approach as specified in section 4.6.

6.5B.3.2.2.4.3 Message Contents

Message contents are according to TS 36.508 [11] clause 4.6 and TS 38.508-1 [6] clause 4.6.1 with the following exceptions.

Table 6.5B.3.2.2.4.3-1: RRCConnectionReconfiguration: nr-Config-r15.

Derivation Path: TS 36.508 [11], Table 4.6.1-8

Information Element

Value/remark

Comment

Condition

p-MaxEUTRA-r15

23

Power Class 2 UE

20

Power Class 3 UE

Table 6.5B.3.2.2.4.3-2: PhysicalCellGroupConfig

Derivation Path: TS 38.508-1 [6] Table 4.6.3-106

Information Element

Value/remark

Comment

Condition

p-NR-FR1

23

Power Class 2 UE

20

Power Class 3 UE

Table 6.5B.3.2.2.4.3-3: SystemInfomationBlockType1: tdd-Config if operating on TDD band

Derivation Path: TS 36.508 [11], Table 4.6.3-23

Information Element

Value/remark

Comment

Condition

TDD-Config-DEFAULT ::= SEQUENCE {

Operating on TDD band

subframeAssignment

sa2

specialSubframePatterns

ssp7

}

6.5B.3.2.2.5 Test Requirement

Test requirements for Spurious Emissions UE Co-existence for intra-band non-contiguous EN-DC are the same as the minimum requirements described in clause 6.5B.3.2.2.3 and are not repeated in this clause.

For EN-DC only capable devices, in addition to Table 6.5B.3.2.2.3-1, test requirements for NR carrier are the same as Table 6.5.3.2.5-1 in TS 38.521-1 [8].

6.5B.3.3 Spurious Emissions for Inter-band EN-DC within FR1

6.5B.3.3.1 General spurious emissions for Inter-band EN-DC within FR1

6.5B.3.3.1.1 Test purpose

To verify that UE transmitter does not cause unacceptable interference to other channels or other systems in terms of transmitter spurious emissions.

6.5B.3.3.1.2 Test applicability

This test case applies to all types of NR UE release 15 and forward supporting inter-band EN-DC.

6.5B.3.3.1.3 Minimum conformance requirements

The general spurious emissions requirements specified in subclause 6.6.3.1 of TS 36.101 [5], subclause 6.5.3.1 of TS 38.101-1 [2] and TS 38.101-2 [3] apply for each component carrier. For the case of inter-band EN-DC with a single carrier per cell group, the general spurious emissions requirements also apply with both downlink carrier and both uplink carriers active. Limits on configured maximum output power for the uplink according to subclause 6.2B.4 apply.

NOTE: The general spurious emission requirements with both uplink carriers active are allowed to be verified for only a single inter-band EN-DC configuration per NR band. Furthermore, the requirements are allowed to be verified by measuring spurious emissions at the specific frequencies where second and third order intermodulation products generated by the two transmitted carriers can occur.

The normative reference for this requirement is TS 38.101-3 [4] clause 6.5B.3.3.1. Exception requirements applicable for both NR and LTE, therefore LTE anchor agnostic approach is not applied.

6.5B.3.3.1.4 Test description

6.5B.3.3.1.4.1 Initial condition

Initial conditions are a set of test configurations the UE needs to be tested in and the steps for the SS to take with the UE to reach the correct measurement state.

The initial test configurations consist of environmental conditions, test frequencies, DC configuration specified in Table 5.5B.4.1-1 and test channel bandwidths specified in TS 36.508 [11] clause 4.3.1 and TS 38.508-1 [6] clause 4.3.1, and sub-carrier spacing based on NR operating bands specified in TS 38.521-1 [8] clause 5.3. All of these configurations shall be tested with applicable test parameters for each EN-DC configuration, and are shown in Table 6.5B.3.3.1.4.1-1. The details of the uplink reference measurement channels (RMCs) are specified in TS 36.521-1 [10] Annexe A, clause A.2.3 for E-UTRA RMC for TDD, TS 36.521-1 [10] Annex A, clause A.2.2 for E-UTRA RMC for FDD, and TS 38.521-1 [8] Annex A, clause A.2 for NR RMC. Configurations of PDSCH and PDCCH before measurement are specified in TS 36.521-1 [10] Annex C.2 and in TS 38.521-1 [8] Annex C.2 for E-UTRA CG and NR CG respectively.

Table 6.5B.3.3.1.4.1-1: Test configuration table

Initial Conditions

Test Environment

as specified in TS 38.508-1 [6] clause 4.1

Normal

Test Frequencies

as specified in TS 38.508-1 [6] clause 4.3.1

Low range for PCC and SCC

High range for PCC and SCC

Test EN-DC channel bandwidth as specified in TS 36.508 [11] clause 4.3.1 and TS 38.508-1 [6] clause 4.3.1

5 MHz for E-UTRA CC and Lowest for NR CC

Highest for E-UTRA CC and Highest for NR CC

Test SCS for the NR cell as specified in TS 38.521-1 [8] Table 5.3.5-1

Lowest SCS per Channel Bandwidth

Test Parameters

Test ID

Downlink Configuration

EN-DC Uplink Configuration

E-UTRA Cell

NR Cell

Modulation

RB allocation

(NOTE 2)

Modulation

RB allocation (NOTE 1)

1

N/A for Spurious emission.

QPSK

Outer_1RB_Left

CP-OFDM QPSK

Edge_1RB_Left

2

QPSK

Outer_1RB_Right

CP-OFDM QPSK

Edge_1RB_Right

3

QPSK

Outer_Full

CP-OFDM QPSK

Outer_Full

NOTE 1: The specific configuration of each RB allocation is defined in Table 6.1-1 in TS 38.521-1 [8].

NOTE 2: Outer_Full defined as the transmission bandwidth configuration NRB per channel bandwidth for the E-UTRA component as indicated in TS 36.521-1 [10] Table 5.4.2-1. Outer_1RB_Left defined as 1 RB allocated at the left edge of the E-UTRA component. Outer_1RB_Right defined as 1 RB allocated at the right edge of the E-UTRA component.

NOTE 3: Only applicable to UEs not supporting UE capability singleUL-Transmission.

NOTE 4: Only one EN-DC combination per FR1 band is tested for each EN-DC configuration as defined in clause 5.5B.4.

1. Connect the SS to the UE antenna connectors as shown in TS 38.508-1 [6] Annex A, Figure A.3.1.1.1 for SS diagram and clause A.3.2.1 for UE diagram.

2. The parameter settings for the cell are set up according to TS 38.508-1 [6] clause 4.4.3.

3. E-UTRA downlink signals are initially set up according to Annex C.0, C.1 and C.3.0, and uplink signals according to Annex H.1 and H.3.0 of TS 36.521-1 [10].

4. NR downlink signals are initially set up according to Annex C.0, C.1 and C.2, and uplink signals according to Annex G.0, G.1, G.2, G.3.0 of TS 38.521-1 [8].

5. The UL Reference Measurement channels are set according to TS 36.521-1 [10] Annex A.2 and TS 38.521-1 [8] Annex A.2 for E-UTRA CG and NR CG respectively.

6. Propagation conditions are set according to TS 36.521-1 [10] Annex B and TS 38.521-1 [8] Annex B for E-UTRA link and NR link respectively.

7. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508-1 [6] clause 4.5. Message contents are defined in clause 6.5B.3.3.1.4.3.

8. For both E-UTRA and NR UL uplink carriers active when both bands are TDD, ensure E-UTRA UL transmission overlaps with NR UL transmission in time by giving SCG a delay of 3 E-UTRA subframes, or by giving MCG a delay of 2 subframes.

6.5B.3.3.1.4.2 Test procedure

1. E-UTRA SS sends uplink scheduling information for each UL HARQ process via PDCCH DCI format 0 for C_RNTI to schedule the UL RMC according to Table 6.5B.3.3.1.4.1-1. Since the UE has no payload data to send, the UE transmits uplink MAC padding bits on the UL RMC.

2. NR SS sends uplink scheduling information for each UL HARQ process via PDCCH DCI format 0_1 for C_RNTI to schedule the UL RMC according to Table 6.5B.3.3.1.4.1-1. Since the UE has no payload data to send, the UE transmits uplink MAC padding bits on the UL RMC.

3. Send continuously uplink power control "up" commands to the UE for both NR and E-UTRA carriers until the UE transmits at its PUMAX level; allow at least 200 ms starting from the first TPC command in this step for the UE to reach PUMAX level.

4. Measure the power of the transmitted signal with a measurement filter of bandwidths according to Table 6.5B.3.3.1.5-1. The centre frequency of the filter shall be stepped in contiguous steps according to the same table. The measured power shall be verified for each step. The measurement period shall capture the active time slots.

5. For UE operating on EN-DC configuration with Band n41, redo the test for frequency range 1 GHz ≤ f < 12.75 GHz with the message content in step 7 of initial conditions with exceptions defined in Table 6.5B.3.3.1.4.3-4.

In addition to test configuration and test procedure above, EN-DC only capable UEs and UEs not supporting NR/5GC mode in the tested band need to be tested according to LTE anchor agnostic below.

Same test description as in clause 6.5.3.1.4 in TS 38.521-1 [8] for the NR carrier with the following exceptions:

The initial test configurations for E-UTRA consist of test frequency based on E-UTRA operating band and test channel bandwidth as specified in Table 4.6-1.

For Initial conditions as in clause 6.5.3.1.4.1 in TS 38.521-1 [8], the following steps will be added to configure E-UTRA component:

2.1. The parameter settings for the cell are set up according to TS 36.508 [11] clause 4.4.3.

3.1. The E-UTRA downlink signal level, uplink signal level are set according to Table 4.6-1 and propagation conditions are set according to Annex B.0 of TS 36.521-1 [10].

Step 6 of Initial conditions as in clause 6.5.3.1.4.1 in TS 38.521-1 [8] is replaced by the following two steps:

6. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508 [6] clause 4.5.

7. On the E-UTRA carrier, disable periodic and aperiodic CQI reports, disable SRS, set TimeAlignmentTimerDedicated IE to infinity and disable downlink and uplink scheduling, all as per Table 4.6-1 under clause 4.6.

6.5B.3.3.1.4.3 Message Contents

Message contents are according to TS 36.508 [11] clause 4.6 and TS 38.508-1 [6] clause 4.6.1 with the following exceptions.

Table 6.5B.3.3.1.4.3-1: SystemInfomationBlockType1: tdd-Config if E-UTRA on TDD band

Derivation Path: TS 36.508 [11], Table 4.6.3-23

Information Element

Value/remark

Comment

Condition

TDD-Config-DEFAULT ::= SEQUENCE {

Operating on TDD band

subframeAssignment

Sa2

specialSubframePatterns

Ssp7

}

Table 6.5B3.3.1.4.3-1a: Void

Table 6.5B.3.3.1.4.3-2: RRCConnectionReconfiguration: nr-Config-r15

Derivation Path: TS 36.508 [11], Table 4.6.1-8

Information Element

Value/remark

Comment

Condition

p-MaxEUTRA-r15

23

Power Class 2 UE AND simultaneous E-UTRA and NR transmission

20

Power Class 3 UE AND simultaneous E-UTRA and NR transmission

Table 6.5B.3.3.1.4.3-3: PhysicalCellGroupConfig

Derivation Path: TS 38.508-1 [6] Table 4.6.3-106

Information Element

Value/remark

Comment

Condition

p-NR-FR1

23

Power Class 2 UE AND simultaneous E-UTRA and NR transmission

20

Power Class 3 UE AND simultaneous E-UTRA and NR transmission

Exception for step 5 in test procedure:

Table 6.5B.3.3.1.4.3-4: Message contents

Derivation Path: TS 38.508-1 [5], Table 4.6.3-1

Information Element

Value/remark

Comment

Condition

additionalSpectrumEmission

1 (NS_04)

6.5B.3.3.1.5 Test Requirement

For EN-DC configurations listed in Table 6.5B.3.3.1.5-1, the corresponding test requirements of the same table apply.

For EN-DC configurations without test requirements specified in Table 6.5B.3.3.1.5-1, the test requirements in clause 6.5B.3.1.1.5 shall apply.

For EN-DC only capable devices, for EN-DC configurations listed in Table 6.5B.3.3.1.5-1, in addition to Table 6.5B.3.3.1.5-1, test requirements for NR carrier are the same as Table 6.5.3.1.5-1 in TS 38.521-1 [8].

Table 6.5B.3.3.1.5-1: General spurious emissions test requirements

Frequency Range

Maximum
Level

Measurement
Bandwidth

Note

Test requirements for DC_1A_n3A configuration

135 MHz ≤ f ≤ 270 MHz

-36 dBm

100 kHz

1440 MHz ≤ f ≤ 1650 MHz
2055 MHz ≤ f ≤ 2250 MHz
3630 MHz ≤ f ≤ 3765 MHz
5340 MHz ≤ f ≤ 5745 MHz

-30 dBm

1 MHz

Test requirements for DC_1A_n5A configuration

222 MHz ≤ f ≤ 332 MHz

-36 dBm

100 kHz

1071 MHz ≤ f ≤ 1156 MHz
2744 MHz ≤ f ≤ 2829 MHz
2991 MHz ≤ f ≤ 3136 MHz
3568 MHz ≤ f ≤ 3678 MHz
4664 MHz ≤ f ≤ 4809 MHz

-30 dBm

1 MHz

Test requirements for DC_1A_n7A configuration

520 MHz ≤ f ≤ 650 MHz

-36 dBm

100 kHz

1270 MHz ≤ f ≤ 1460 MHz
3020 MHz ≤ f ≤ 3220 MHz
4420 MHz ≤ f ≤ 4550 MHz
6340 MHz ≤ f ≤ 6530 MHz
6920 MHz ≤ f ≤ 7120 MHz

-30 dBm

1 MHz

Test requirements for DC_1A_n8A configuration

90 MHz ≤ f ≤ 220 MHz

-36 dBm

100 kHz

1005 MHz ≤ f ≤ 1100 MHz
2800 MHz ≤ f ≤ 2895 MHz
2925 MHz ≤ f ≤ 3080 MHz
3680 MHz ≤ f ≤ 3810 MHz
4720 MHz ≤ f ≤ 4875 MHz

-30 dBm

1 MHz

Test requirements for DC_1A_n28A configuration

424 MHz ≤ f ≤ 574 MHz

-36 dBm

100 kHz

1172 MHz ≤ f ≤ 1277 MHz
2623 MHz ≤ f ≤ 2728 MHz
3092 MHz ≤ f ≤ 3257 MHz
3326 MHz ≤ f ≤ 3476 MHz
4543 MHz ≤ f ≤ 4708 MHz

-30 dBm

1 MHz

Test requirements for DC_1A_n77A Configuration

360 MHz ≤ f ≤ 660 MHz

-36 dBm

100 kHz

1320 MHz ≤ f ≤ 2280 MHz
4620 MHz ≤ f ≤ 6480 MHz
7140 MHz ≤ f ≤ 8160 MHz
8520 MHz ≤ f ≤ 10380 MHz

-30 dBm

1 MHz

Test requirements for DC_1A_n78A Configuration

40 MHz ≤ f ≤ 660 MHz

-36 dBm

100 kHz

1320 MHz ≤ f ≤ 1880 MHz
4620 MHz ≤ f ≤ 5780 MHz
7140 MHz ≤ f ≤ 7760 MHz
8520 MHz ≤ f ≤ 9580 MHz

-30 dBm

1 MHz

Test requirements for DC_1A_n79A Configuration

440 MHz ≤ f ≤ 1000 MHz

-36 dBm

100 kHz

1000 MHz ≤ f ≤ 1160 MHz
2420 MHz ≤ f ≤ 3080 MHz
6320 MHz ≤ f ≤ 8080 MHz
8240 MHz ≤ f ≤ 8960 MHz
10720 MHz ≤ f ≤ 11980 MHz

-30 dBm

1 MHz

Test requirements for DC_2A_n5A Configuration

152 MHz ≤ f ≤ 262 MHz

-36 dBm

100 kHz

1001 MHz ≤ f ≤ 1086 MHz

2674 MHz ≤ f ≤ 2759 MHz

2851 MHz ≤ f ≤ 2996 MHz

3498 MHz ≤ f ≤ 3608 MHz

4524 MHz ≤ f ≤ 4669 MHz

-30 dBm

1 MHz

Test requirements for DC_2A_n41A Configuration

586 MHz ≤ f ≤ 840 MHz

-36 dBm

100 kHz

1010 MHz ≤ f ≤ 1324 MHz
3082 MHz ≤ f ≤ 3530 MHz
4346 MHz ≤ f ≤ 4600 MHz
6196 MHz ≤ f ≤ 6510 MHz
6842 MHz ≤ f ≤ 7290 MHz

-30 dBm

1 MHz

2

-25 dBm

1 MHz

1

Test requirements for DC_2A_n71A Configuration

454 MHz ≤ f ≤ 584 MHz

-36 dBm

100 kHz

1152 MHz ≤ f ≤ 1247 MHz 2513 MHz ≤ f ≤ 2608 MHz

3002 MHz ≤ f ≤ 3157 MHz

3176 MHz ≤ f ≤ 3306 MHz

4363 MHz ≤ f ≤ 4518 MHz

-30 dBm

1 MHz

Test requirements for DC_2A_n77A Configuration

500 MHz ≤ f ≤ 520 MHz

-36 dBm

100 kHz

1390 MHz ≤ f ≤ 2350 MHz
4690 MHz ≤ f ≤ 6550 MHz
7000 MHz ≤ f ≤ 8020 MHz
8450 MHz ≤ f ≤ 10310 MHz

-30 dBm

1 MHz

Test requirements for DC_3A_n1A Configuration

135 MHz ≤ f ≤ 270 MHz

-36 dBm

100 kHz

1440 MHz ≤ f ≤ 1650 MHz
2055 MHz ≤ f ≤ 2250 MHz
3630 MHz ≤ f ≤ 3765 MHz
5340 MHz ≤ f ≤ 5745 MHz

-30 dBm

1 MHz

Test requirements for DC_3A_n5A Configuration

12 MHz ≤ f ≤ 30 MHz

-36 dBm

10 kHz

30 MHz ≤ f ≤ 137 MHz
861 MHz ≤ f ≤ 961 MHz

-36 dBm

100 kHz

2534 MHz ≤ f ≤ 2746 MHz
3358 MHz ≤ f ≤ 3483 MHz
4244 MHz ≤ f ≤ 4419 MHz

-30 dBm

1 MHz

Test requirements for DC_3A_n7A Configuration

715 MHz ≤ f < 1000 MHz

-36 dBm

100 kHz

1000 MHz ≤ f ≤ 1070 MHz

3215 MHz ≤ f ≤ 3430 MHz

4210 MHz ≤ f ≤ 4355 MHz

5920 MHz ≤ f ≤ 6140 MHz

6710 MHz ≤ f ≤ 6925 MHz

-30 dBm

1 MHz

Test requirements for DC_3A_n8A Configuration

25 MHz ≤ f ≤ 30 MHz

-36 dBm

10 kHz

30 MHz ≤ f ≤ 120 MHz
795 MHz ≤ f ≤ 905 MHz

-36 dBm

100 kHz

2505 MHz ≤ f ≤ 2700 MHz
3470 MHz ≤ f ≤ 3615 MHz
4300 MHz ≤ f ≤ 4485 MHz

-30 dBm

1 MHz

Test requirements for DC_3A_n28A Configuration

214 MHz ≤ f ≤ 379 MHz
962 MHz ≤ f ≤ 1000 MHz

-36 dBm

100 kHz

1000 MHz ≤ f ≤ 1082 MHz
2413 MHz ≤ f ≤ 2533 MHz
2672 MHz ≤ f ≤ 2867 MHz
3116 MHz ≤ f ≤ 3281 MHz
4123 MHz ≤ f ≤ 4318 MHz

-30 dBm

1 MHz

Test requirements for DC_3A_n41A Configuration

711 MHz ≤ f < 1000 MHz

-36 dBm

100 kHz

1000MHz ≤ f ≤ 1074 MHz
3207MHz ≤ f ≤ 3670 MHz
4206MHz ≤ f ≤ 4475 MHz
5916MHz ≤ f ≤ 6260 MHz
6702MHz ≤ f ≤ 7165 MHz

-30 dBm

1 MHz

2

-25 dBm

1 MHz

1

Test requirements for DC_3A_n77A Configuration

270 MHz ≤ f ≤ 780 MHz

-36 dBm

100 kHz

1515 MHz ≤ f ≤ 2490 MHz
4815 MHz ≤ f ≤ 6690 MHz
6720 MHz ≤ f ≤ 7770 MHz
8310 MHz ≤ f ≤ 10185 MHz

-30 dBm

1 MHz

Test requirements for DC_3A_n78A Configuration

270 MHz ≤ f ≤ 380 MHz

-36 dBm

100 kHz

1515 MHz ≤ f ≤ 2090 MHz
4815 MHz ≤ f ≤ 5890 MHz
6720 MHz ≤ f ≤ 7370 MHz
8310 MHz ≤ f ≤ 9385 MHz

-30 dBm

1 MHz

Test requirements for DC_3A_n79A Configuration

830 MHz ≤ f ≤ 1000 MHz

-36 dBm

100 kHz

1000 MHz ≤ f ≤ 1580 MHz
2615 MHz ≤ f ≤ 3290 MHz
6110 MHz ≤ f ≤ 6785 MHz
7015 MHz ≤ f ≤ 8570 MHz
10510 MHz ≤ f ≤ 11785 MHz

-30 dBm

1 MHz

Test requirements for DC_5A_n2A Configuration

152 MHz ≤ f ≤ 262 MHz

-36 dBm

100 kHz

1001 MHz ≤ f ≤ 1086 MHz

2674 MHz ≤ f ≤ 2759 MHz

2851 MHz ≤ f ≤ 2996 MHz

3498 MHz ≤ f ≤ 3608 MHz

4524 MHz ≤ f ≤ 4669 MHz

-30 dBm

1 MHz

Test requirements for DC_5A_n66A Configuration

12 MHz ≤ f ≤ 30 MHz

-36 dBm

10 kHz

30 MHz ≤ f ≤ 132 MHz
861 MHz ≤ f ≤ 956 MHz

-36 dBm

100 kHz

2534 MHz ≤ f ≤ 2736 MHz
3358 MHz ≤ f ≤ 3478 MHz
4244 MHz ≤ f ≤ 4409 MHz

-30 dBm

1 MHz

Test requirements for DC_5A_n77A Configuration

1602 MHz ≤ f ≤ 3376 MHz
4124 MHz ≤ f ≤ 9249 MHz

-30 dBm

1 MHz

 

Test requirements for DC_5A_n78A Configuration

1602 MHz ≤ f ≤ 2152 MHz
2451 MHz ≤ f ≤ 2976 MHz
4124 MHz ≤ f ≤ 4649 MHz
4948 MHz ≤ f ≤ 5498 MHz
5751 MHz ≤ f ≤ 6776 MHz
7424 MHz ≤ f ≤ 8449 MHz

-30 dBm

1 MHz

Test requirements for DC_7A_n1A Configuration

520 MHz ≤ f ≤ 650 MHz

-36 dBm

100 kHz

1270 MHz ≤ f ≤ 1460 MHz
3020 MHz ≤ f ≤ 3220 MHz
4420 MHz ≤ f ≤ 4550 MHz
6340 MHz ≤ f ≤ 6530 MHz

6920 MHz ≤ f ≤ 7120 MHz

-30 dBm

1 MHz

Test requirements for DC_7A_n3A Configuration

715 MHz ≤ f < 1000 MHz

-36 dBm

100 kHz

1000 MHz ≤ f ≤ 1070 MHz 3215 MHz ≤ f ≤ 3430 MHz
4210 MHz ≤ f ≤ 4355 MHz
5920 MHz ≤ f ≤ 6140 MHz

6710 MHz ≤ f ≤ 6925 MHz

-30 dBm

1 MHz

Test requirements for DC_7A_n5A Configuration

802 MHz ≤ f ≤ 922 MHz

-36 dBm

100 kHz

1651 MHz ≤ f ≤ 1746 MHz
3324 MHz ≤ f ≤ 3419 MHz
4148 MHz ≤ f ≤ 4316 MHz
5824 MHz ≤ f ≤ 5989 MHz

-30 dBm

1 MHz

Test requirements for DC_7A_n8A Configuration

670 MHz ≤ f ≤ 810 MHz

-36 dBm

100 kHz

1585 MHz ≤ f ≤ 1690 MHz
3380 MHz ≤ f ≤ 3485 MHz
4085 MHz ≤ f ≤ 4400 MHz
5880 MHz ≤ f ≤ 6055 MHz

-30 dBm

1 MHz

Test requirements for DC_7A_n28A Configuration

1004 MHz ≤ f ≤ 1164 MHz
1752 MHz ≤ f ≤ 1867 MHz
3203 MHz ≤ f ≤ 3318 MHz
3906 MHz ≤ f ≤ 4066 MHz
4252 MHz ≤ f ≤ 4437 MHz
5703 MHz ≤ f ≤ 5888 MHz

-30 dBm

1 MHz

Test requirements for DC_7A_n78A Configuration

730 MHz ≤ f ≤ 1000 MHz

-36 dBm

100 kHz

1000 MHz ≤ f ≤ 1840 MHz
4030 MHz ≤ f ≤ 5100 MHz
5800 MHz ≤ f ≤ 6370 MHz
8300 MHz ≤ f ≤ 8940 MHz
9100 MHz ≤ f ≤ 10170 MHz

-30 dBm

1 MHz

Test requirements for DC_8A_n1A Configuration

90 MHz ≤ f ≤ 220 MHz

-36 dBm

100 kHz

1005 MHz ≤ f ≤ 1100 MHz
2800 MHz ≤ f ≤ 2895 MHz
2925 MHz ≤ f ≤ 3080 MHz
3680 MHz ≤ f ≤ 3810 MHz
4720 MHz ≤ f ≤ 4875 MHz

-30 dBm

1 MHz

Test requirements for DC_8A_n3A Configuration

25 MHz ≤ f < 30 MHz

-36 dBm

10 kHz

30 MHz ≤ f ≤ 120 MHz

795 MHz ≤ f ≤ 905 MHz

-36 dBm

100 kHz

2505 MHz ≤ f ≤ 2700 MHz
3470 MHz ≤ f ≤ 3615 MHz
4300 MHz ≤ f ≤ 4485 MHz

-30 dBm

1 MHz

Test requirements for DC_8A_n20A Configuration

18 MHz ≤ f < 30 MHz

-36 dBm

10 kHz

30 MHz ≤ f ≤ 83 MHz

749 MHz ≤ f ≤ 844 MHz

898 MHz ≤ f ≤ 998 MHz

-36 dBm

100 kHz

1712 MHz ≤ f ≤ 1777 MHz

2544 MHz ≤ f ≤ 2692 MHz

-30 dBm

1 MHz

Test requirements for DC_8A_n28A Configuration

132 MHz ≤ f ≤ 212 MHz
491 MHz ≤ f ≤ 616 MHz

-36 dBm

100 kHz

1012 MHz ≤ f ≤ 1127 MHz
1583 MHz ≤ f ≤ 1663 MHz
2286 MHz ≤ f ≤ 2411 MHz
2463 MHz ≤ f ≤ 2578 MHz

-30 dBm

1 MHz

Test requirements for DC_8A_n41A Configuration

666 MHz ≤ f ≤ 930 MHz

-36 dBm

100 kHz

1581MHz ≤ f ≤ 1810 MHz
3376MHz ≤ f ≤ 3605 MHz
4077MHz ≤ f ≤ 4520 MHz
5872MHz ≤ f ≤ 6295 MHz

-30 dBm

1 MHz

2

-25 dBm

1 MHz

1

Test requirements for DC_8A_n77A Configuration

1470 MHz ≤ f ≤ 3320 MHz
4180 MHz ≤ f ≤ 9315 MHz

-30 dBm

1 MHz

Test requirements for DC_8A_n78A Configuration

1470 MHz ≤ f ≤ 2040 MHz
2385 MHz ≤ f ≤ 2920 MHz
4180 MHz ≤ f ≤ 4715 MHz
5060 MHz ≤ f ≤ 5630 MHz
5685 MHz ≤ f ≤ 6720 MHz
7480 MHz ≤ f ≤ 8515 MHz

-30 dBm

1 MHz

Test requirements for DC_11A_n77A Configuration

404.2 MHz ≤ f ≤ 1000 MHz

-36 dBm

100 kHz

1000 MHz ≤ f ≤ 1344.2 MHz
1852.1 MHz ≤ f ≤ 2772.1 MHz
4727.9 MHz ≤ f ≤ 7095.8 MHz
8027.9 MHz ≤ f ≤ 9847.9 MHz

-30 dBm

1 MHz

Test requirements for DC_11A_n78A Configuration

404.2 MHz ≤ f ≤ 944.2 MHz

-36 dBm

100 kHz

1852.1 MHz ≤ f ≤ 2372.1 MHz
4727.9 MHz ≤ f ≤ 6695.8 MHz
8027.9 MHz ≤ f ≤ 9047.9 MHz

-30 dBm

1 MHz

Test requirements for DC_11A_n79A Configuration

1504.2 MHz ≤ f ≤ 2144.2 MHz
2952.1 MHz ≤ f ≤ 3572.1 MHz
5827.9 MHz ≤ f ≤ 6447.9 MHz
7255.8 MHz ≤ f ≤ 8572.1 MHz
10227.9 MHz ≤ f ≤ 11447.9 MHz

-30 dBm

1 MHz

Test requirements for DC_12A_n66A Configuration

278 MHz ≤ f ≤ 382 MHz
994 MHz ≤ f < 1000 MHz

-36 dBm

100 kHz

1000 MHz ≤ f ≤ 1081 MHz
2409 MHz ≤ f ≤ 2496 MHz
2704 MHz ≤ f ≤ 2861 MHz
3108 MHz ≤ f ≤ 3212 MHz
4119 MHz ≤ f ≤ 4276 MHz

-30 dBm

1 MHz

Test requirements for DC_12A_n78A Configuration

1868 MHz ≤ f ≤ 2402 MHz
2584 MHz ≤ f ≤ 3101 MHz
3999 MHz ≤ f ≤ 4516 MHz
4698 MHz ≤ f ≤ 5232 MHz
5884 MHz ≤ f ≤ 6901 MHz
7299 MHz ≤ f ≤ 8316 MHz

-30 dBm

1 MHz

Test requirements for DC_13A_n2A Configuration

276 MHz ≤ f ≤ 356 MHz

-36 dBm

100 kHz

1063 MHz ≤ f ≤ 1133 MHz

2627 MHz ≤ f ≤ 2697 MHz

2913 MHz ≤ f ≤ 3043 MHz

3404 MHz ≤ f ≤ 3484 MHz

4477 MHz ≤ f ≤ 4607 MHz

-30 dBm

1 MHz

Test requirements for DC_13A_n66A Configuration

136 MHz ≤ f ≤ 226 MHz

923 MHz ≤ f ≤ 1000 MHz

-36 dBm

100 kHz

1000 MHz ≤ f ≤ 1003 MHz

2487 MHz ≤ f ≤ 2567 MHz

2633 MHz ≤ f ≤ 2783 MHz

3264 MHz ≤ f ≤ 3354 MHz

4197 MHz ≤ f ≤ 4347 MHz

-30 dBm

1 MHz

Test requirements for DC_13A_n77A Configuration

1726 MHz ≤ f ≤ 3423 MHz
4077 MHz ≤ f ≤ 5774 MHz
5813 MHz ≤ f ≤ 9187 MHz

-30 dBm

1 MHz

 

Test requirements for DC_14A_n2A Configuration

254 MHz ≤ f ≤ 334 MHz

-36 dBm

100 kHz

1052 MHz ≤ f ≤ 1122 MHz

2638 MHz ≤ f ≤ 2708 MHz

2902 MHz ≤ f ≤ 3032 MHz

3426 MHz ≤ f ≤ 3506 MHz

4488 MHz ≤ f ≤ 4618 MHz

-30 dBm

1 MHz

Test requirements for DC_14A_n66A Configuration

114 MHz ≤ f ≤ 204 MHz

912 MHz ≤ f ≤ 992 MHz

-36 dBm

100 kHz

2498 MHz ≤ f ≤ 2578 MHz

2622 MHz ≤ f ≤ 2772 MHz

3286 MHz ≤ f ≤ 3376 MHz

4208 MHz ≤ f ≤ 4358 MHz

-30 dBm

1 MHz

Test requirements for DC_19A_n1A Configuration

230 MHz <= f <= 320 MHz

-36 dBm

100 kHz

1075 MHz <= f <= 1150 MHz

2750 MHz <= f <= 2825 MHz

2995 MHz <= f <= 3130 MHz

3580 MHz <= f <= 3670 MHz

4670 MHz <= f <= 4805 MHz

-30 dBm

1 MHz

Test requirements for DC_19A_n77A Configuration

1610 MHz ≤ f ≤ 3370 MHz
4130 MHz ≤ f ≤ 5890 MHz
5755 MHz ≤ f ≤ 9245 MHz

-30 dBm

1 MHz

Test requirements for DC_19A_n78A Configuration

1610 MHz ≤ f ≤ 2140 MHz
2455 MHz ≤ f ≤ 2970 MHz
4130 MHz ≤ f ≤ 4645 MHz
4960 MHz ≤ f ≤ 5490 MHz
5755 MHz ≤ f ≤ 6770 MHz
7430 MHz ≤ f ≤ 8445 MHz

-30 dBm

1 MHz

Test requirements for DC_19A_n79A Configuration

2710 MHz ≤ f ≤ 3340 MHz
3555 MHz ≤ f ≤ 4170 MHz
5230 MHz ≤ f ≤ 5845 MHz
6060 MHz ≤ f ≤ 6690 MHz
7955 MHz ≤ f ≤ 9170 MHz
9630 MHz ≤ f ≤ 10845 MHz

-30 dBm

1 MHz

Test requirements for DC_20A_n1A Configuration

196 MHz ≤ f ≤ 316 MHz

-36 dBm

100 kHz

1058 MHz ≤ f ≤ 1148 MHz
2752 MHz ≤ f ≤ 2842 MHz
2978 MHz ≤ f ≤ 3128 MHz
3584 MHz ≤ f ≤ 3704 MHz

4672 MHz ≤ f ≤ 4822 MHz

-30 dBm

1 MHz

Test requirements for DC_20A_n3A Configuration

14 MHz ≤ f < 30 MHz

-36 dBm

10 kHz

30 MHz ≤ f ≤ 121 MHz

848 MHz ≤ f ≤ 953 MHz

-36 dBm

100 kHz

2542 MHz ≤ f ≤ 2738 MHz
3374 MHz ≤ f ≤ 3509 MHz
4252 MHz ≤ f ≤ 4432 MHz

-30 dBm

1 MHz

Test requirements for DC_20A_n7A Configuration

776 MHz ≤ f ≤ 906 MHz

-36 dBm

100 kHz

1638 MHz ≤ f ≤ 1738 MHz

3332 MHz ≤ f ≤ 3432 MHz

4138 MHz ≤ f ≤ 4308 MHz

5832 MHz ≤ f ≤ 6002 MHz

-30 dBm

1 MHz

Test requirements for DC_20A_n8A Configuration

18 MHz ≤ f < 30 MHz

-36 dBm

10 kHz

30 MHz ≤ f ≤ 83 MHz
749 MHz ≤ f ≤ 844 MHz
898 MHz ≤ f ≤ 998 MHz

-36 dBm

100 kHz

1712 MHz ≤ f ≤ 1777 MHz
2544 MHz ≤ f ≤ 2692 MHz

-30 dBm

1 MHz

Test requirements for DC_20A_n28A Configuration

84 MHz ≤ f ≤ 159 MHz
544 MHz ≤ f ≤ 664 MHz
916 MHz ≤ f ≤ 1000 MHz

-36 dBm

100 kHz

1000 MHz ≤ f ≤ 1021 MHz
1535 MHz ≤ f ≤ 1610 MHz
2238 MHz ≤ f ≤ 2358 MHz
2367 MHz ≤ f ≤ 2472 MHz

-30 dBm

1 MHz

Test requirements for DC_20A_n78A Configuration

1576 MHz ≤ f ≤ 2136 MHz
2438 MHz ≤ f ≤ 2968 MHz
4132 MHz ≤ f ≤ 4662 MHz
4964 MHz ≤ f ≤ 5524 MHz
5738 MHz ≤ f ≤ 6768 MHz
7432 MHz ≤ f ≤ 8462 MHz

-30 dBm

1 MHz

Test requirements for DC_21A_n1A Configuration

457.1 MHz ≤ f ≤ 532.1 MHz

915.8 MHz ≤ f ≤ 1000 MHz

-36 dBm

100 kHz

2377.1 MHz ≤ f ≤ 2512.1 MHz

3367.9 MHz ≤ f ≤ 3442.9 MHz

4815.8 MHz ≤ f ≤ 4905.8 MHz

5287.9 MHz ≤ f ≤ 5422.9 MHz

-30 dBm

1 MHz

Test requirements for DC_21A_n77A Configuration

374.2 MHz ≤ f ≤ 1000 MHz

-36 dBm

100 kHz

1000 MHz ≤ f ≤ 1304.2 MHz
1837.1 MHz ≤ f ≤ 2752.1 MHz
4747.9 MHz ≤ f ≤ 7125.8 MHz
8047.9 MHz ≤ f ≤ 9862.9 MHz

-30 dBm

1 MHz

Test requirements for DC_21A_n78A Configuration

374.2 MHz ≤ f ≤ 904.2 MHz

-36 dBm

100 kHz

1837.1 MHz ≤ f ≤ 2352.1 MHz
4747.9 MHz ≤ f ≤ 6152.1 MHz
6195.8 MHz ≤ f ≤ 6725.8 MHz
8047.9 MHz ≤ f ≤ 9062.9 MHz

-30 dBm

1 MHz

Test requirements for DC_21A_n79A Configuration

1474.2 MHz ≤ f ≤ 2104.2 MHz
2937.1 MHz ≤ f ≤ 3552.1 MHz
5847.9 MHz ≤ f ≤ 6462.9 MHz
7295.8 MHz ≤ f ≤ 8552.1 MHz
10247.9 MHz ≤ f ≤ 11462.9 MHz

-30 dBm

1 MHz

Test requirements for DC_25A_n41A Configuration

581 MHz ≤ f ≤ 840 MHz

-36 dBm

100 kHz

1010 MHz ≤ f ≤ 1334 MHz
3077 MHz ≤ f ≤ 3530 MHz
4346 MHz ≤ f ≤ 4605 MHz
6196 MHz ≤ f ≤ 6520 MHz
6842 MHz ≤ f ≤ 7295 MHz

-30 dBm

1 MHz

2

-25 dBm

1 MHz

1

Test requirements for DC_26A_n41A Configuration

798 MHz ≤ f < 1000 MHz

-36 dBm

100 kHz

1000 MHz ≤ f ≤ 1062 MHz
1647 MHz ≤ f ≤ 1876 MHz
3310 MHz ≤ f ≤ 3539 MHz
4124 MHz ≤ f ≤ 4566 MHz
5806 MHz ≤ f ≤ 6229 MHz

-30 dBm

1 MHz

2

-25 dBm

1 MHz

1

Test requirements for DC_26A_n77A Configuration

1602 MHz ≤ f ≤ 3386 MHz
4114 MHz ≤ f ≤ 5898 MHz
5751 MHz ≤ f ≤ 9249 MHz

-30 dBm

1 MHz

Test requirements for DC_26A_n78A Configuration

1602 MHz ≤ f ≤ 2172 MHz
2451 MHz ≤ f ≤ 2986 MHz
4114 MHz ≤ f ≤ 4649 MHz
4928 MHz ≤ f ≤ 5498 MHz
5751 MHz ≤ f ≤ 6786 MHz
7414 MHz ≤ f ≤ 8449 MHz

-30 dBm

1 MHz

Test requirements for DC_26A_n79A Configuration

2702 MHz ≤ f ≤ 3372 MHz
3551 MHz ≤ f ≤ 4186 MHz
5214 MHz ≤ f ≤ 5849 MHz
6028 MHz ≤ f ≤ 6698 MHz
7951 MHz ≤ f ≤ 9186 MHz
9614 MHz ≤ f ≤ 10849 MHz

-30 dBm

1 MHz

Test requirements for DC_28A_n3A Configuration

214 MHz ≤ f ≤ 379 MHz
962 MHz ≤ f < 1000 MHz

-36 dBm

100 kHz

1000 MHz ≤ f ≤ 1082 MHz
2413 MHz ≤ f ≤ 2533 MHz
2672 MHz ≤ f ≤ 2867 MHz
3116 MHz ≤ f ≤ 3281 MHz
4123 MHz ≤ f ≤ 4318 MHz

-30 dBm

1 MHz

Test requirements for DC_28A_n5A Configuration

76 MHz ≤ f ≤ 146 MHz

557 MHz ≤ f ≤ 672 MHz

900 MHz ≤ f ≤ 995 MHz

-36 dBm

100 kHz

1527 MHz ≤ f ≤ 1597 MHz

2230 MHz ≤ f ≤ 2345 MHz

2351 MHz ≤ f ≤ 2446 MHz

-30 dBm

1 MHz

Test requirements for DC_28A_n7A Configuration

1004 MHz ≤ f ≤ 1164 MHz
1752 MHz ≤ f ≤ 1867 MHz
3203 MHz ≤ f ≤ 3318 MHz
3906 MHz ≤ f ≤ 4066 MHz
4252 MHz ≤ f ≤ 4437 MHz
5703 MHz ≤ f ≤ 5888 MHz

-30 dBm

1 MHz

Test requirements for DC_28A_n77A Configuration

1804 MHz ≤ f ≤ 3497 MHz
4003 MHz ≤ f ≤ 5696 MHz
5852 MHz ≤ f ≤ 9148 MHz

-30 dBm

1 MHz

Test requirements for DC_28A_n78A Configuration

1804 MHz ≤ f ≤ 2394 MHz

2552 MHz ≤ f ≤ 3097 MHz

4003 MHz ≤ f ≤ 4548 MHz

4706 MHz ≤ f ≤ 5296 MHz

5852 MHz ≤ f ≤ 6897 MHz

7303 MHz ≤ f ≤ 8348 MHz

-30 dBm

1 MHz

Test requirements for DC_28A_n79A Configuration

2904 MHz ≤ f ≤ 3594 MHz
3652 MHz ≤ f ≤ 4297 MHz
5103 MHz ≤ f ≤ 5748 MHz
5806 MHz ≤ f ≤ 6496 MHz
8052 MHz ≤ f ≤ 9297 MHz
9503 MHz ≤ f ≤ 10748 MHz

-30 dBm

1 MHz

Test requirements for DC_30A_n5A Configuration

607 MHz ≤ f ≤ 667 MHz

-36 dBm

100 kHz

1456 MHz ≤ f ≤ 1491 MHz
3129 MHz ≤ f ≤ 3164 MHz
3761 MHz ≤ f ≤ 3806 MHz
3953 MHz ≤ f ≤ 4013 MHz
5434 MHz ≤ f ≤ 5479 MHz

-30 dBm

1 MHz

Test requirements for DC_39A_n41A Configuration

576 MHz ≤ f < 810 MHz

-36 dBm

100 kHz

1070MHz ≤ f ≤ 1344 MHz
3072MHz ≤ f ≤ 3500 MHz
4376MHz ≤ f ≤ 4610 MHz
6256MHz ≤ f ≤ 6530 MHz
6872MHz ≤ f ≤ 7300 MHz

-30 dBm

1 MHz

2

-25 dBm

1 MHz

1

Test requirements for DC_39A_n79A Configuration

560 MHz ≤ f ≤ 1000 MHz

-36 dBm

100 kHz

1000 MHz ≤ f ≤ 1240 MHz
2480 MHz ≤ f ≤ 3120 MHz
6280 MHz ≤ f ≤ 8120 MHz
8160 MHz ≤ f ≤ 8840 MHz
10680 MHz ≤ f ≤ 11920 MHz

-30 dBm

1 MHz

Test requirements for DC_40A_n1A Configuration

320 MHz ≤ f ≤ 480 MHz

-36 dBm

100 kHz

1440 MHz ≤ f ≤ 1660 MHz
2620 MHz ≤ f ≤ 2880 MHz
4220 MHz ≤ f ≤ 4380 MHz
6140 MHz ≤ f ≤ 6360 MHz
6520 MHz ≤ f ≤ 6780 MHz

-30 dBm

1 MHz

Test requirements for DC_40A_n41A Configuration

96 MHz ≤ f < 390 MHz

-36 dBm

100 kHz

1910 MHz ≤ f ≤ 2304 MHz
2592 MHz ≤ f ≤ 3080 MHz
4796 MHz ≤ f ≤ 5090 MHz
7096 MHz ≤ f ≤ 7780 MHz

-30 dBm

1 MHz

2

-25 dBm

1 MHz

1

Test requirements for DC_40A_n78A Configuration

800 MHz ≤ f ≤ 1000 MHz

-36 dBm

100 kHz

1000 MHz ≤ f ≤ 1500 MHz
4200 MHz ≤ f ≤ 5300 MHz
5600 MHz ≤ f ≤ 6200 MHz
7900 MHz ≤ f ≤ 8600 MHz
8900 MHz ≤ f ≤ 10000 MHz

-30 dBm

1 MHz

Test requirements for DC_40A_n79A Configuration

2000 MHz ≤ f ≤ 2700 MHz

6400 MHz ≤ f ≤ 7700 MHz

9000 MHz ≤ f ≤ 9800 MHz

11100 MHz ≤ f ≤ 12400 MHz

-30 dBm

1 MHz

Test requirements for DC_41A_n77A Configuration

610 MHz ≤ f ≤ 1000 MHz

-36 dBm

100 kHz

1000 MHz ≤ f ≤ 2080 MHz
3910 MHz ≤ f ≤ 6890 MHz
8292 MHz ≤ f ≤ 11090 MHz

-30 dBm

1 MHz

Test requirements for DC_41A_n78A Configuration

610 MHz ≤ f ≤ 1000 MHz

-36 dBm

100 kHz

1000 MHz ≤ f ≤ 2080 MHz
3910 MHz ≤ f ≤ 5104 MHz
5796 MHz ≤ f ≤ 6490 MHz
8292 MHz ≤ f ≤ 10290 MHz

-30 dBm

1 MHz

Test requirements for DC_41A_n79A Configuration

8 MHz ≤ f ≤ 30 MHz

-36 dBm

10 kHz

30 MHz ≤ f ≤ 980 MHz

-36 dBm

100 kHz

1710 MHz ≤ f ≤ 2504 MHz
6110 MHz ≤ f ≤ 7690 MHz
9392 MHz ≤ f ≤ 10380 MHz
11296 MHz ≤ f ≤ 12690 MHz

-30 dBm

1 MHz

Test requirements for DC_42A_n77A Configuration

300 MHz ≤ f ≤ 800 MHz

-36 dBm

100 kHz

2600 MHz ≤ f ≤ 5000 MHz
6700 MHz ≤ f ≤ 7800 MHz
10000 MHz ≤ f ≤ 12000 MHz

-30 dBm

1 MHz

Test requirements for DC_48A_n5A Configuration

1852 MHz ≤ f ≤ 2052 MHz
2701 MHz ≤ f ≤ 2876 MHz
4374 MHz ≤ f ≤ 4549 MHz
5198 MHz ≤ f ≤ 5398 MHz
6251 MHz ≤ f ≤ 6576 MHz
7924 MHz ≤ f ≤ 8249 MHz

-30 dBm

1 MHz

Test requirements for DC_48A_n66A Configuration

10 MHz ≤ f < 30 MHz

-36 dBm

10 KHz

30 MHz ≤ f ≤ 280 MHz

-36 dBm

100 KHz

1770 MHz ≤ f ≤ 1990 MHz
5260 MHz ≤ f ≤ 5690 MHz
6970 MHz ≤ f ≤ 7260 MHz
8810 MHz ≤ f ≤ 9180 MHz

-30 dBm

1 MHz

Test requirements for DC_66A_n5A Configuration

12 MHz ≤ f ≤ 30 MHz

-36 dBm

10 kHz

30 MHz ≤ f ≤ 132 MHz
861 MHz ≤ f ≤ 956 MHz

-36 dBm

100 kHz

2534 MHz ≤ f ≤ 2736 MHz
3358 MHz ≤ f ≤ 3478 MHz
4244 MHz ≤ f ≤ 4409 MHz

-30 dBm

1 MHz

Test requirements for DC_66A_n41A Configuration

716 MHz ≤ f < 1000 MHz

-36 dBm

100 kHz

1000 MHz ≤ f ≤ 1064 MHz
3212 MHz ≤ f ≤ 3670 MHz
4206 MHz ≤ f ≤ 4470 MHz
5916 MHz ≤ f ≤ 6250 MHz
6702 MHz ≤ f ≤ 7160 MHz

-30 dBm

1 MHz

2

-25 dBm

1 MHz

1

Test requirements for DC_66A_n71A Configuration

314 MHz ≤ f ≤ 454 MHz

-36 dBm

100 kHz

1102 MHz ≤ f ≤ 1117 MHz

2373 MHz ≤ f ≤ 2478 MHz

2722 MHz ≤ f ≤ 2897 MHz

3036 MHz ≤ f ≤ 3176 MHz

4083 MHz ≤ f ≤ 4258 MHz

-30 dBm

1 MHz

Test requirements for DC_66A_n77A Configuration

260MHz ≤ f ≤ 780 MHz

-36 dBm

100 kHz

 

1520 MHz ≤ f ≤ 2490MHz
5010 MHz ≤ f ≤ 6690 MHz
6720 MHz ≤ f ≤ 7760 MHz
8310 MHz ≤ f ≤ 10180 MHz

-30 dBm

1 MHz

 

Test requirements for DC_66A_n78A Configuration

260 MHz ≤ f ≤ 380 MHz

-36 dBm

100 kHz

1520 MHz ≤ f ≤ 2090 MHz
4820 MHz ≤ f ≤ 5890 MHz
6720 MHz ≤ f ≤ 7360 MHz
8310 MHz ≤ f ≤ 9380 MHz

-30 dBm

1 MHz

NOTE 1: Applies for Band n41, CA configurations including Band n41, and EN-DC configurations that include n41 specified in clause 5.2B of TS 36.101 [5] when NS_04 is signalled.

NOTE 2: Does not apply for Band n41, CA configurations including Band n41, and EN-DC configurations that include n41 specified in subclause 5.2B of TS 38.101-3 [4] when NS_04 is signalled.

6.5B.3.3.2 Spurious emission band UE co-existence for Inter-band within FR1

Editor’s note: The default and additional test configuration is analysed based on the assumption that only intermodulation products need to be tested. The band combinations without TP analysis in TR 38.905 are incomplete.

6.5B.3.3.2.1 Test purpose

To verify that UE transmitter does not cause unacceptable interference to other channels or other systems in terms of transmitter spurious emissions for band UE co-existence for inter-band EN-DC.

6.5B.3.3.2.2 Test applicability

This test case applies to all types of E-UTRA UE release 15 and forward supporting inter-band EN-DC.

6.5B.3.3.2.3 Minimum conformance requirements

This clause specifies the requirements for the specified EN-DC, for coexistence with protected bands. The requirements in Table 6.5B.3.3.2.3-1 and Table 6.5B.3.3.2.3-2 apply on each component carrier with all component carriers are active.

NOTE: For inter-band EN_DC with the uplink assigned to one LTE band and one NR band, the requirements in Table 6.5B.3.3.2.3-1 and Table 6.5B.3.3.2.3-2 could be verified by measuring spurious emissions at the specific frequencies where second and third order intermodulation products generated by the two transmitted carriers can occur.

Table 6.5B.3.3.2.3-1: Spurious emission band UE co-existence limits Rel-15

EN-DC Configuration

Spurious emission

Protected band

Frequency range (MHz)

Maximum Level (dBm)

MBW (MHz)

NOTE

DC_1_n28

E-UTRA Band 5, 7, 8, 18, 19, 20, 26, 27, 31, 38, 40, 41, 72, 73

NR band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 22, 32, 42, 43, 50, 51, 52, 65, 74, 75, 76

NR band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA band n3, n34

FDL_low

FDL_high

-50

1

5

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 1, 65

FDL_low

FDL_high

-50

1

9, 10

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

662

694

-26.2

6

5

Frequency range

1880

1895

-40

1

5, 16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

DC_1_n77

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 20, 21, 26, 28, 34, 40, 41, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

1880

1895

-40

1

5, 8

Frequency range

1895

1915

-15.5

5

5, 7, 8

Frequency range

1915

1920

+1.6

5

5, 7, 8

DC_1_n78

DC_1_n84_ULSUP-TDM_n78

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 20, 21, 26, 28, 34, 40, 41, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

1880

1895

-40

1

5, 8

Frequency range

1895

1915

-15.5

5

5, 7, 8

Frequency range

1915

1920

+1.6

5

5, 7, 8

DC_1_n79

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 21, 26, 28, 34, 40, 41, 42, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

1880

1895

-40

1

5, 8

Frequency range

1895

1915

-15.5

5

5, 7, 8

Frequency range

1915

1920

+1.6

5

5, 7, 8

DC_2_n5

E-UTRA Bands 4, 5, 12, 13, 14, 17, 24, 26, 28, 29, 30, 42, 48, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Bands 2, 25

FDL_low

FDL_high

-50

1

2

E-UTRA Band 41, 43, 53

FDL_low

FDL_high

-50

1

2

DC_2_n66

E-UTRA Bands 4, 5, 12, 13, 14, 17, 24, 26, 27, 28, 29, 30, 41, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Bands 2, 25

FDL_low

FDL_high

-50

1

5

E-UTRA Bands 42, 48

FDL_low

FDL_high

-50

1

2

DC_2_n71

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 29, 30, 48, 66

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25, 41, 70

FDL_low

FDL_high

-50

1

2

E-UTRA Band n71

FDL_low

FDL_high

-50

1

5

DC_2_n78

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 27, 28, 29, 30, 41, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

2

DC_3_n7

E-UTRA Band 1, 5, 7, 8, 20, 26, 27, 28, 31, 32, 33, 34, 40, 43, 44, 50, 51, 65, 67, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA band 3

FDL_low

FDL_high

-50

1

5

E-UTRA band 22, 42

FDL_low

FDL_high

-50

1

2

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_3_n8

E-UTRA Band 1, 11, 20, 21, 28, 31, 32, 33, 34, 38, 39, 40, 45, 50, 51, 65, 67,68, 69, 72, 73, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA band 3, 8

FDL_low

FDL_high

-50

1

2, 5

E-UTRA band 7, 22, 41, 42, 43, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n28

E-UTRA Band 1, 42, 43, 50, 51, 65, 74, 75, 76

NR band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA band 1

FDL_low

FDL_high

-50

1

9, 11

E-UTRA band 3

FDL_low

FDL_high

-50

1

5

E-UTRA Band 5, 7, 8, 18, 19, 20, 26, 27, 31, 34, 38, 40, 41, 72

FDL_low

FDL_high

-50

1

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 10

Frequency range

1884.5

1915.7

-41

0.3

13

Frequency range

470

710

-26.2

6

14

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3, 9

DC_3_n77

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 20, 21, 26, 28, 34, 39, 40, 41, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n78

DC_3_n80_ULSUP-TDM_n78

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 20, 21, 26, 28, 34, 39, 40, 41, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n79

DC_3_n80_ULSUP-TDM_n79

E-UTRA Band 1, 3, 5, 8, 11, 18, 19, 21, 28, 34, 39, 40, 41, 65, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 42

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_5_n66

E-UTRA Band 1, 2, 3, 4, 5, 6, 7, 8, 12, 13, 14, 17, 24, 25, 28, 29, 30, 34, 38, 40, 43, 45, 50, 51, 65, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 26

859

869

-27

1

E-UTRA Band 41, 42, 48, 52

FDL_low

FDL_high

-50

1

2

DC_5_n78

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 12, 13, 14, 17, 24, 25, 28, 29, 30, 31, 34, 38, 40, 45, 65, 66, 70

FDL_low

FDL_high

-50

1

E-UTRA Band 26

859

869

-27

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2,7

DC_7_n28

E-UTRA Band 2, 3, 5, 7, 8, 20, 26, 27, 31, 34, 40, 72

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 4, 42, 43, 50, 65, 66, 74, 75, 76

NR band n78

FDL_low

FDL_high

-50

1

2

E-UTRA band 1

FDL_low

FDL_high

-50

1

9, 10

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_7_n78

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 11, 18, 19, 20, 21, 26, 27, 28, 31, 32, 33, 34, 40, 50, 51, 65, 66, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_8_n77

E-UTRA Band 1, 20, 28, 31, 32, 33, 34, 38, 39, 40, 44, 45, 50, 51, 65, 67, 68, 69, 72, 73, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA band 3, 7, 41

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

12

Frequency range

860

890

-40

1

5, 12

Frequency range

1884.5

1915.7

-41

0.3

3, 12

DC_8_n78

DC_8_n81_ULSUP-TDM_n78

E-UTRA Band 1, 20, 28, 34, 39, 40, 65, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 7,41

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

12

Frequency range

860

890

-40

1

5, 12

Frequency range

1884.5

1915.7

-41

0.3

3, 12

DC_11_n77

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_11_n78

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_11_n79

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 42, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_12_n66

E-UTRA Band 2, 5, 13, 14, 17, 25, 26, 27, 30, 41, 71, 74

FDL_low

FDL_high

-50

1

E-UTRA Bands 4, 48, 50, 51, 66, 70

FDL_low

FDL_high

-50

1

2

E-UTRA Band 12, 85

FDL_low

FDL_high

-50

1

5

DC_19_n77

E-UTRA Band 1, 3, 11, 21, 28, 34, 40, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_19_n78

E-UTRA Band 1, 3, 11, 21, 28, 34, 40, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_19_n79

E-UTRA Band 1, 3, 11, 21, 28, 34, 40, 42, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_20_n28

DC_20_n83

E-UTRA Band 3, 7, 8, 31, 34

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 22, 32, 38, 42, 43, 65, 75, 76

NR Band n78

FDL_low

FDL_high

-50

1

2

DC_20_n78

DC_20_n82_ULSUP-TDM_n78

E-UTRA Band 1, 3, 7, 8, 31, 32, 33, 34, 40, 50, 51, 65, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

FDL_low

E-UTRA Band 20

FDL_low

FDL_high

-50

1

5

E-UTRA Band 38, 69

FDL_low

FDL_high

-50

1

2

DC_21_n77

E-UTRA Band 1, 3, 18, 19, 21, 28, 34, 40, 42, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_21_n78

E-UTRA Band 1, 3, 18, 19, 21, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_21_n79

E-UTRA Band 1, 3, 18, 19, 21, 28, 34, 42, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_25_n41

E-UTRA band 4, 5, 12, 13, 14, 17, 24, 26, 27, 28, 29, 30, 42, 45, 48, 66, 70,71

FDL_low

FDL_high

-50

1

E-UTRA/NR Band 2, 25

FDL_low

FDL_high

-50

1

5

DC_26_n41

E-UTRA/NR Band 1, 2, 3, 4, 5, 11, 12, 13, 14, 17, 18, 19, 21, 24, 25, 26, 29, 30, 31, 34, 39, 42, 43, 48, 50, 51, 65, 66, 70, 71, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

703

799

-50

1

Frequency range

799

803

-40

1

5

Frequency range

945

960

-50

1

DC_26_n77

E-UTRA Band 1, 3, 5, 11, 18, 19, 21, 26, 34, 39, 40, 65, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

Frequency range

703

799

-50

1

Frequency range

799

803

-40

1

5

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

2

Frequency range

2595

2645

-50

1

DC_26_n78

E-UTRA Band 1, 3, 5, 11, 18, 19, 21, 26, 34, 39, 40, 65, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

2

Frequency range

703

799

-50

1

Frequency range

799

803

-40

1

5

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

2

Frequency range

2595

2645

-50

1

DC_26_n79

E-UTRA Band 1, 3, 5, 11, 18, 19, 21, 26, 34, 39, 40, 42, 65, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

Frequency range

703

799

-50

1

Frequency range

799

803

-40

1

5

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

2

Frequency range

2595

2645

-50

1

DC_28_n77

E-UTRA Band 3, 5, 7, 8, 18, 19, 20, 26, 34, 39, 40, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 65, 74

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 10

Frequency range

758

773

-32

1

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3, 9

DC_28_n78

DC_28_n83_ULSUP-TDM_n78

E-UTRA Band 3, 5, 7, 8, 18, 19, 20, 26, 34, 39, 40, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 65, 74

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 10

Frequency range

758

773

-32

1

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3, 9

DC_28_n79

E-UTRA Band 3, 5, 8, 18, 19, 34, 39, 40, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 42, 65, 74

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 10

Frequency range

758

773

-32

1

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3, 9

DC_30_n5

E-UTRA Band 2, 4, 5, 7, 12, 13, 14, 17, 24, 25, 26, 29, 30, 38, 48, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 41, 48, 52

FDL_low

FDL_high

-50

1

2

DC_38_n78

N/A

DC_39_n79

E-UTRA Band 1, 8, 34, 40, 41, 44, 45

FDL_low

FDL_high

-50

1

Frequency range

1805

1855

-40

1

18

Frequency range

1855

1880

-15.5

5

18

DC_40_n77

N/A

DC_41_n77

E-UTRA Band 1, 3, 5, 8, 11, 18, 19, 21, 26, 28, 33, 34, 39, 40, 44, 45, 73, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_41_n78

E-UTRA Band 1, 3, 5, 8, 11, 18, 19, 21, 26, 28, 34, 39, 40, 44, 45, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_41_n79

E-UTRA Band 1, 3, 5, 8, 11, 18, 19, 21, 26, 28, 34, 40, 42, 44, 45, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_42_n77

N/A

DC_42_n78

N/A

DC_42_n79

N/A

DC_66_n5

E-UTRA Band 1, 2, 3, 4, 5, 6, 7, 8, 12, 13, 14, 17, 24, 25, 26, 28, 29, 30, 34, 38, 40, 43, 45, 50, 51, 65, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 41, 42, 48, 52

FDL_low

FDL_high

-50

1

2

DC_66_n71

E-UTRA Band 4, 5, 13, 14, 17, 24, 26, 27, 29, 30, 43, 50, 51, 66, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 7,22, 25, 41, 42, 48, 70

FDL_low

FDL_high

-50

1

2

E-UTRA Band 71

FDL_low

FDL_high

-50

1

5

DC_66_n78,

DC_66_n86_ULSUP-TDM_n78

E-UTRA Band 1, 3, 5, 7, 8, 20, 26, 28, 34, 39, 40, 41, 65

FDL_low

FDL_high

-50

1

NOTE 1: FDL_low and FDL_high refer to each frequency band specified in Table 5.5-1 of TS 36.101 [5] or in Table 5.2-1 in TS 38.101-1 [2].

NOTE 2: As exceptions, measurements with a level up to the applicable requirements defined in Table 6.6.3.1-2 in TS 36.101 [5] and Table 6.5.3.1-2 in TS 38.101-1 [2] are permitted for each assigned carrier used in the measurement due to 2nd, 3rd, 4th or 5th harmonic spurious emissions. Due to spreading of the harmonic emission the exception is also allowed for the first 1 MHz frequency range immediately outside the harmonic emission on both sides of the harmonic emission. This results in an overall exception interval centred at the harmonic emission of (2MHz + N x LCRB x 180kHz), where N is 2, 3, 4, 5 for the 2nd, 3rd, 4th or 5th harmonic respectively. The exception is allowed if the measurement bandwidth (MBW) totally or partially overlaps the overall exception interval.

NOTE 3: Applicable when co-existence with PHS system operating in 1884.5 -1915.7MHz.

NOTE 4: Void.

NOTE 5: These requirements also apply for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1, Table 6.6.3.1A-1 in TS 36.101 [5] or in Table 6.5.3.1-1 in TS 38.101-1 [2] from the edge of the channel bandwidth.

NOTE 6: This requirement is applicable for any channel bandwidths within the range 2500 – 2570 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 2560.5 – 2562.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 2552 – 2560 MHz the requirement is applicable only for an uplink transmission bandwidth less than or equal to 54 RB.

NOTE 7: For these adjacent bands, the emission limit could imply risk of harmful interference to UE(s) operating in the protected operating band.

NOTE 8: This requirement is applicable for any channel bandwidths within the range 1920 – 1980 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 1927.5 – 1929.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 1930 – 1938 MHz the requirement is applicable only for an uplink

NOTE 9: Applicable when the assigned E-UTRA carrier is confined within 718 MHz and 748 MHz and when the channel bandwidth used is 5 or 10 MHz.

NOTE 10: As exceptions, measurements with a level up to the applicable requirement of -38 dBm/MHz is permitted for each assigned E-UTRA carrier used in the measurement due to 2nd harmonic spurious emissions. An exception is allowed if there is at least one individual RB within the transmission bandwidth (see Figure 5.6-1) for which the 2nd harmonic totally or partially overlaps the measurement bandwidth (MBW).

NOTE 11: As exceptions, measurements with a level up to the applicable requirement of -36 dBm/MHz is permitted for each assigned E-UTRA carrier used in the measurement due to 3rd harmonic spurious emissions. An exception is allowed if there is at least one individual RB within the transmission bandwidth (see Figure 5.6-1) for which the 3rd harmonic totally or partially overlaps the measurement bandwidth (MBW).

NOTE 12: This requirement is applicable only for the following cases:
A: for carriers of 5 MHz channel bandwidth when carrier centre frequency (Fc) is within the range 902.5 MHz ≤ Fc < 907.5 MHz with an uplink transmission bandwidth less than or equal to 20 RB;
B: for carriers of 5 MHz channel bandwidth when carrier centre frequency (Fc) is within the range 907.5 MHz ≤ Fc ≤ 912.5 MHz without any restriction on uplink transmission bandwidth.
C: for carriers of 10 MHz channel bandwidth when carrier centre frequency (Fc) is Fc = 910 MHz with an uplink transmission bandwidth less than or equal to 32 RB with RBstart > 3.

NOTE 13: Void.

NOTE 14: This requirement is applicable for 5 and 10 MHz E-UTRA channel bandwidth allocated within 718-728MHz. For carriers of 10 MHz bandwidth, this requirement applies for an uplink transmission bandwidth less than or equal to 30 RB with RBstart > 1 and Rbstart < 48.

NOTE 15: Void.

NOTE 16: This requirement is applicable for any channel bandwidths within the range 1920 – 1980 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 1927.5 – 1929.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 1930 – 1938 MHz the requirement is applicable only for an uplink transmission bandwidth less than or equal to 54 RB.

NOTE 17: This requirement is applicable in the case of a 10 MHz E-UTRA carrier confined within 703 MHz and 733 MHz, otherwise the requirement of -25 dBm with a measurement bandwidth of 8 MHz applies.

NOTE 18: This requirement is only applicable for E-UTRA carriers with bandwidth confined within 1885 – 1920 MHz (requirement for carriers with at least 1RB confined within 1880 – 1885 MHz is not specified). This requirement applies for an uplink transmission bandwidth less than or equal to 54 RB for E-UTRA carriers of 15 MHz bandwidth when carrier centre frequency is within the range 1892.5 – 1894.5 MHz and for E-UTRA carriers of 20 MHz bandwidth when carrier centre frequency is within the range 1895 – 1903 MHz.

NOTE 19: Void.

Table 6.5B.3.3.2.3-2: Spurious emission band UE co-existence limits Rel-16

EN-DC Configuration

Spurious emission

Protected band

Frequency range (MHz)

Maximum Level (dBm)

MBW (MHz)

NOTE

DC_1_n3

E-UTRA Band 1, 5, 7, 8, 11, 18, 19, 20, 21, 26, 27, 28, 31, 32, 38, 40, 43, 44, 50, 51, 65, 67, 72, 73, 74, 75, 76

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 34

FDL_low

FDL_high

-50

1

5

E-UTRA Band 22, 42, 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

1880

1895

-40

1

5,16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

DC_1_n5

E-UTRA Band 1, 5, 7, 8, 11, 18, 19, 21, 22, 26, 28, 31, 38, 40, 42, 43, 50, 51, 65, 73, 74

FDL_low

FDL_high

-50

1

E-UTRA band 3,34

FDL_low

FDL_high

-50

1

5

E-UTRA band 41, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

DC_1_n7

E-UTRA Band 1, 5, 7, 8, 20, 22, 26, 27, 28, 31,32, 40, 42, 43, 50, 51, 52, 65, 67, 72, 74, 75, 76

NR Band n78, n79

FDL_low

FDL_high

-50

1

band n77

FDL_low

FDL_high

-50

1

2

band 3, 34

FDL_low

FDL_high

-50

1

5

Frequency range

1880

1895

-40

1

5,16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_1_n8

E-UTRA Band 11, 20, 21, 28, 31, 32, 38, 40, 45, 50, 51, 65, 67, 68, 69, 72, 73, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA band 3, 7, 22, 41, 42, 43, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1, 8, 34

FDL_low

FDL_high

-50

1

5

Frequency range

1880

1895

-40

1

5, 16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

DC_1_n28

E-UTRA Band 5, 7, 8, 18, 19, 20, 26, 27, 31, 38, 40, 41, 72, 73

NR band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 22, 32, 42, 43, 50, 51, 52, 65, 74, 75, 76

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA Band 3, 34

FDL_low

FDL_high

-50

1

5

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 1, 65

FDL_low

FDL_high

-50

1

9, 10

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

662

694

-26.2

6

5

Frequency range

1880

1895

-40

1

5, 16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

DC_1_n77

DC_1_n84_ULSUP-TDM_n77

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 20, 21, 26, 28, 34, 40, 41, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

1880

1895

-40

1

5, 8

Frequency range

1895

1915

-15.5

5

5, 7, 8

Frequency range

1915

1920

+1.6

5

5, 7, 8

DC_1_n78

DC_1_n84_ULSUP-TDM_n78

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 20, 21, 26, 28, 34, 40, 41, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

1880

1895

-40

1

5, 8

Frequency range

1895

1915

-15.5

5

5, 7, 8

Frequency range

1915

1920

+1.6

5

5, 7, 8

DC_1_n79

DC_1_n84_ULSUP-TDM_n79

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 21, 26, 28, 34, 40, 41, 42, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

1880

1895

-40

1

5, 8

Frequency range

1895

1915

-15.5

5

5, 7, 8

Frequency range

1915

1920

+1.6

5

5, 7, 8

DC_2_n5

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 28, 29, 30, 42, 48, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

2, 5

E-UTRA Band 2, 25, 48

FDL_low

FDL_high

-50

1

5

E-UTRA Band 41, 43, 53

FDL_low

FDL_high

-50

1

2

DC_2_n41

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 27, 28, 29, 30, 42, 48, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Bands 2, 25

FDL_low

FDL_high

-50

1

5

E-UTRA Band 43

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_2_n66

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 27, 28, 29, 30, 41, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

5

E-UTRA Band 42, 48

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_2_n71

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 29, 30, 48, 66

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25, 41, 70

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band n71

FDL_low

FDL_high

-50

1

5

DC_2_n78

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 27, 28, 29, 30, 41, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

2

DC_3_n1

E-UTRA Band 1, 5, 7, 8, 11, 18, 19, 20, 21, 26, 27, 28, 31, 32, 38, 40, 41, 43, 44, 50, 51, 65, 67, 72, 73, 74, 75, 76

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 34

FDL_low

FDL_high

-50

1

5

E-UTRA Band 22, 42, 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

1880

1895

-40

1

5,16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

DC_3_n5

E-UTRA Band 1, 5, 7, 8, 11, 18, 19, 21, 26, 28, 31, 38, 40, 43, 50, 51, 65, 73, 74

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA band 3,34

FDL_low

FDL_high

-50

1

5

E-UTRA Band 22, 42, 52

Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n7

E-UTRA Band 1, 5, 7, 8, 20, 26, 27, 28, 31, 32, 33, 34, 40, 43, 44, 50, 51, 65, 67, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 3

FDL_low

FDL_high

-50

1

5

E-UTRA Band 22, 42

FDL_low

FDL_high

-50

1

2

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_3_n28

E-UTRA Band 1, 42, 43, 50, 51, 65, 74, 75, 76

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 3

FDL_low

FDL_high

-50

1

5

E-UTRA Band 5, 7, 8, 18, 19, 20, 26, 27, 31, 34, 38, 40, 41, 72

FDL_low

FDL_high

-50

1

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 10

Frequency range

1884.5

1915.7

-41

0.3

13

Frequency range

470

710

-26.2

6

14

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3, 9

DC_3_n41,

DC_3_n80_ULSUP-TDM_n41

E-UTRA Band 1, 5, 8, 11, 18, 19, 21, 26, 27, 28, 34, 39, 40, 44, 45, 50, 51, 65, 73, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 42, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n77

DC_3_n80_ULSUP-TDM_n77

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 20, 21, 26, 28, 34, 39, 40, 41, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n78

DC_3_n80_ULSUP-TDM_n78

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 20, 21, 26, 28, 34, 39, 40, 41, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n79

DC_3_n80_ULSUP-TDM_n79

E-UTRA Band 1, 3, 5, 8, 11, 18, 19, 21, 28, 34, 39, 40, 41, 65, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 42

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_5_n2

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 28, 29, 30, 42, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 25

FDL_low

FDL_high

-50

1

5

NR Band n2

FDL_low

FDL_high

-50

1

5

E-UTRA Band 26

859

869

-27

1

E-UTRA Band 41, 43, 53

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_5_n66

E-UTRA Band 1, 2, 3, 4, 5, 6, 7, 8, 12, 13, 14, 17, 24, 25, 28, 29, 30, 34, 38, 40, 43, 45, 50, 51, 65, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 26

859

869

-27

1

E-UTRA Band 41, 42, 48, 52

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_5_n78

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 12, 13, 14, 17, 24, 25, 28, 29, 30, 31, 34, 38, 40, 45, 65, 66, 70

FDL_low

FDL_high

-50

1

E-UTRA Band 26

859

869

-27

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2,7

DC_7_n1

E-UTRA Band 1, 5, 7, 8, 20, 22, 26, 27, 28, 31,32, 40, 42, 43, 50, 51, 52, 65, 67, 72, 74, 75, 76

NR Band n78, n79

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 3, 34

FDL_low

FDL_high

-50

1

5

Frequency range

1880

1895

-40

1

5,16

Frequency range

1895

1915

-15.5

5

5, 7,16

Frequency range

1915

1920

+1.6

5

5, 7,16

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_7_n3

E-UTRA Band 1, 5, 7, 8, 20, 26, 27, 28, 31, 32, 33, 34, 40, 43, 50, 51, 65, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 3

FDL_low

FDL_high

-50

1

5

E-UTRA Band 22, 42, 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_7_n5

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 12, 13, 14, 17, 22, 26, 28, 29, 30, 31, 40, 42, 43, 50, 51, 65, 66, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

2570

2575

+1.6

5

5, 7, 6

Frequency range

2575

2595

-15.5

5

5, 7, 6

Frequency range

2595

2620

-40

1

5, 14

DC_7_n8

E-UTRA Band 1, 20, 28, 31, 32, 33, 34, 40, 50, 51, 65, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA band 3, 7, 22, 42, 43, 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_7_n28

E-UTRA Band 2, 3, 5, 7, 8, 20, 26, 27, 31, 34, 40, 72

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 4, 42, 43, 50, 51, 65, 66, 74, 75, 76

NR Band n78

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 10

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_7_n66

E-UTRA Band 2, 4, 5, 7, 12, 13, 14, 17, 26, 27, 28, 29, 30, 43, 50, 51, 66, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 42

FDL_low

FDL_high

-50

1

2

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_7_n78

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 11, 18, 19, 20, 21, 26, 27, 28, 31, 32, 33, 34, 40, 50, 51, 65, 66, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_8_n1

E-UTRA Band 20, 28, 31, 32, 38, 40, 50, 51, 65, 67, 72, 73, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 7, 22, 41, 42, 43, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1, 8, 34

FDL_low

FDL_high

-50

1

5

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

12

Frequency range

860

890

-40

1

5, 12

Frequency range

1880

1895

-40

1

5, 16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

DC_8_n3

E-UTRA Band 1, 20, 28, 31, 32, 33, 34, 38, 39, 40, 44, 50, 51, 65, 67, 72, 73, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 8

FDL_low

FDL_high

-50

1

2, 5

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

12

E-UTRA Band 7, 22, 41, 42, 43, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3, 12

Frequency range

860

890

-40

1

5, 12

DC_8_n20

E-UTRA Band 1, 31, 32, 33, 34, 40, 50, 51, 65, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 7, 22, 38, 42, 43, 52, 69

NR band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8, 20

FDL_low

FDL_high

-50

1

5

Frequency range

758

788

-50

1

DC_8_n28

E-UTRA Band 20, 31, 34, 38, 40, 72

FDL_low

FDL_high

-50

1

E-UTRA band 3, 7, 22, 41, 42, 43, 50, 51, 65, 73, 74, 75, 76

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

2, 9, 11

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 10, 12

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

Frequency range

662

694

-26.2

6

5

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

860

890

-40

1

5, 12

Frequency range

1884.5

1915.7

-41

0.3

3, 9, 12

DC_8_n40

E-UTRA Band 1, 20, 28, 31, 32, 33, 34, 38, 39, 40, 45, 50, 51, 65, 67, 68, 69, 72, 73, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 7, 22, 41, 42, 43, 52

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

DC_8_n41,

DC_8_n81_ULSUP-TDM_n41

E-UTRA Band 1, 11, 21, 28, 34, 39, 40, 45, 50, 51, 65, 73, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 42, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

Frequency range

860

890

-40

1

5, 12

Frequency range

1884.5

1915.7

-41

0.3

3

DC_8_n77

E-UTRA Band 1, 20, 28, 31, 32, 33, 34, 38, 39, 40, 44, 45, 50, 51, 65, 67, 68, 69, 72, 73, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 7, 41

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

12

Frequency range

860

890

-40

1

5, 12

Frequency range

1884.5

1915.7

-41

0.3

3, 12

DC_8_n78

DC_8_n81_ULSUP-TDM_n78,

DC_8_n81_ULSUP-FDM_n78

E-UTRA Band 1, 20, 28, 34, 39, 40, 65, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 7,41

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

12

Frequency range

860

890

-40

1

5, 12

Frequency range

1884.5

1915.7

-41

0.3

3, 12

DC_11_n77

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_11_n78

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_11_n79

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 42, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_12_n66

E-UTRA Band 2, 5, 13, 14, 17, 25, 26, 27, 30, 41, 53, 71, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 48, 50, 51, 66, 70,

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 12, 85

FDL_low

FDL_high

-50

1

5

DC_12_n78

E-UTRA Band 2, 5, 7, 13, 17, 25, 26, 41, 71

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 66

FDL_low

FDL_high

-50

1

2

E-UTRA band 12

FDL_low

FDL_high

-50

1

5

Frequency range

1884.5

1915.7

-41

0.3

3

DC_13_n2

E-UTRA Band 4, 5,12,13,17, 26, 29, 41, 48, 66, 70, 71

FDL_low

FDL_high

-50

1

E-UTRA Band 2,14, 25

FDL_low

FDL_high

-50

1

5

E-UTRA Band 30

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

5

Frequency range

799

805

-35

0.00625

5

DC_13_n66

E-UTRA Band 2, 4, 5, 12, 13, 17, 25, 26, 27, 29, 41, 50, 51, 53, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 14

FDL_low

FDL_high

-50

1

5

E-UTRA Band 30, 48,

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

5

Frequency range

799

803

-35

0.00625

5

DC_14_n2

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 27, 29, 30, 41, 48, 53, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA band 2, 25

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

5

Frequency range

799

805

-35

0.00625

5

DC_14_n66

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 25, 26, 27, 29, 30, 41, 53, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA band 48

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

5

Frequency range

799

805

-35

0.00625

5

DC_19_n77

E-UTRA Band 1, 3, 11, 21, 28, 34, 40, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_19_n78

E-UTRA Band 1, 3, 11, 21, 28, 34, 40, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_19_n79

E-UTRA Band 1, 3, 11, 21, 28, 34, 40, 42, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_20_n1

E-UTRA Band 1, 3, 7, 8, 20, 22, 31, 32, 34, 40, 43, 50, 51, 65, 67, 68, 72, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 38, 42, 69

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

758

788

-50

1

DC_20_n3

E-UTRA Band 1, 7, 8, 31, 32, 33, 34, 40, 43, 50, 51, 65, 67, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 20

E-UTRA Band 3

FDL_low

FDL_high

-50

1

5

E-UTRA Band 22, 38, 42, 52

FDL_low

FDL_high

-50

1

2

Frequency range

758

788

-50

1

DC_20_n7

E-UTRA Band 1, 3, 7, 8, 22, 31, 32, 33, 34, 40, 43, 50, 51, 65, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 42, 52
NR band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA Band 20

FDL_low

FDL_high

-50

1

5

DC_20_n8

E-UTRA Band 1, 28, 31, 32, 34, 65, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 7, 22, 38, 42, 43

NR Band n78

FDL_low

FDL_high

-50

1

2

DC_20_n28

DC_20_n83

E-UTRA Band 3, 7, 8, 31, 34

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 22, 32, 38, 42, 43, 65, 75, 76

FDL_low

FDL_high

-50

1

2

DC_20_n28

DC_20_n83

E-UTRA Band 1, 3, 7, 8, 22, 31, 32, 34, 38, 42, 43, 65, 75, 76

FDL_low

FDL_high

-50

1

DC_20_n78

DC_20_n82_ULSUP-TDM_n78

E-UTRA Band 1, 3, 7, 8, 31, 32, 33, 34, 40, 50, 51, 65, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 20

FDL_low

FDL_high

-50

1

5

E-UTRA Band 38, 69

FDL_low

FDL_high

-50

1

2

DC_21_n77

E-UTRA Band 1, 3, 18, 19, 21, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_21_n78

E-UTRA Band 1, 3, 18, 19, 21, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_21_n79

E-UTRA Band 1, 3, 18, 19, 21, 28, 34, 40, 42, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_25_n41

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 27, 28, 29, 30, 42, 45, 48, 66, 70,71

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25,

FDL_low

FDL_high

-50

1

5

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_26_n41

E-UTRA Band 1, 2, 3, 4, 5, 11, 12, 13, 14, 17, 18, 19, 21, 24, 25, 26, 29, 30, 31, 34, 39, 42, 43, 48, 50, 51, 65, 66, 70, 71, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

703

799

-50

1

Frequency range

799

803

-40

1

5

Frequency range

945

960

-50

1

DC_26_n77

E-UTRA Band 1, 3, 5, 11, 18, 19, 21, 26, 34, 39, 40, 65, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

Frequency range

703

799

-50

1

Frequency range

799

803

-40

1

5

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

2

Frequency range

2595

2645

-50

1

DC_26_n78

E-UTRA Band 1, 3, 5, 11, 18, 19, 21, 26, 34, 39, 40, 65, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

Frequency range

703

799

-50

1

Frequency range

799

803

-40

1

5

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

2

Frequency range

2595

2645

-50

1

DC_26_n79

E-UTRA Band 1, 3, 5, 11, 18, 19, 21, 26, 34, 39, 40, 65, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

Frequency range

703

799

-50

1

Frequency range

799

803

-40

1

5

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_28_n3

E-UTRA Band 1, 22, 42, 43, 50, 51, 65, 74, 75, 76,

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 3, 5, 7, 8, 18, 19, 20, 26, 27, 31, 34, 38, 40, 41, 72, 73

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 10

Frequency range

470

710

-26.2

6

14

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3, 9

DC_28_n5

E-UTRA Band 2, 3, 5, 7, 8, 14, 18, 19, 24, 25, 26, 28, 30, 31, 34, 38, 40, 70, 71

FDL_low

FDL_high

-50

E-UTRA Band 4, 22, 32, 41, 42, 43, 45, 48, 50, 51, 52, 65, 66, 73, 74, 75, 76
NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 10

Frequency range

1884.5

1915.7

-41

0.3

3, 9

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

Frequency range

662

694

-26.2

6

5

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

DC_28_n7

E-UTRA Band 2, 3, 5, 8, 20, 26, 27, 31, 34, 40, 72
NR band n7

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 22, 32, 42, 43, 50, 51, 52, 65, 66, 74, 75, 76

NR band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA band 1

FDL_low

FDL_high

-50

1

2, 9, 10

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_28_n77

E-UTRA Band 3, 5, 7, 8, 18, 19, 20, 26, 34, 39, 40, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 65, 74

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 10

Frequency range

758

773

-32

1

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3, 9

DC_28_n78

DC_28_n83_ULSUP-TDM_n78

E-UTRA Band 3, 5, 7, 8, 18, 19, 20, 26, 34, 39, 40, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 65, 74

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 10

Frequency range

758

773

-32

1

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_28_n79

E-UTRA Band 3, 5, 8, 18, 19, 34, 39, 40, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 42, 65, 74

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 10

Frequency range

758

773

-32

1

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3, 9

DC_30_n5

E-UTRA Band 2, 4, 5, 7, 12, 13, 14, 17, 24, 25, 26, 29, 30, 38, 48, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 41, 53

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_38_n78

N/A

DC_39_n41

E-UTRA Band 1, 8, 26, 28, 34, 40, 42, 44, 45, 50, 51, 74

FDL_low

FDL_high

-50

1

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1805

1855

-40

1

5

Frequency range

1855

1880

-15.5

5

5, 7, 19

DC_39_n79

E-UTRA Band 1, 8, 28, 34, 40, 41, 44, 45

FDL_low

FDL_high

-50

1

Frequency range

1805

1855

-40

1

18

Frequency range

1855

1880

-15.5

5

18

DC_40_n1

E-UTRA Band 1, 3, 5, 7, 8, 20, 22, 26, 27, 28, 31, 32, 38, 41, 42, 43, 44, 45, 50, 51, 52, 65, 67, 68, 69, 72, 73, 74, 75, 76

NR Band n78

FDL_low

FDL_high

-50

1

 

E-UTRA Band 34

FDL_low

FDL_high

-50

1

5

NR Band n77, n79

FDL_low

FDL_high

-50

1

2

DC_40_n41

Bands 1, 3, 5, 8, 26, 27, 28, 34, 39, 42, 44, 45, 50, 51, 65, 73, 74, NR Band n77, n78

FDL_low

FDL_high

-50

1

NR Band n79

FDL_low

FDL_high

-50

1

2

DC_40_n77

N/A

DC_40_n78

E-UTRA Band 1, 3, 5, 7, 8, 18, 19, 20, 21, 26, 27, 28, 31, 32, 33, 34, 38, 39, 41, 44, 45, 50, 51, 65, 67, 68, 69, 72, 73, 74, 75, 76

FDL_low

FDL_high

-50

1

NR Band n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_40_n79

Bands 1, 3, 5, 8, 11, 18, 19, 21, 26, 28, 34, 39, 41, 42, 65, 74

NR band n78

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_41_n77

E-UTRA Band 1, 3, 5, 8, 11, 18, 19, 21, 26, 28, 33, 34, 39, 40, 44, 45, 73, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_41_n78

E-UTRA Band 1, 3, 5, 8, 11, 18, 19, 21, 26, 28, 34, 39, 40, 44, 45, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_41_n79

E-UTRA Band 1, 3, 5, 8, 11, 18, 19, 21, 26, 28, 34, 40, 42, 44, 45, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_42_n77

N/A

DC_42_n78

N/A

DC_42_n79

N/A

DC_48_n5

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 26, 29, 30, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_48_n66

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 26, 29, 30, 41, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

DC_66_n2

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 27, 28, 29, 30, 41, 50, 51, 53, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 25

FDL_low

FDL_high

-50

1

5

E-UTRANR Band n2

FDL_low

FDL_high

-50

1

5

E-UTRA Band 22, 42, 43,

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_66_n5

E-UTRA Band 1, 2, 3, 4, 5, 6, 7, 8, 12, 13, 14, 17, 24, 25, 26, 28, 29, 30, 34, 38, 40, 43, 45, 50, 51, 65, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 41, 42, 48, 52

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_66_n41

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 26, 27, 28, 29, 30, 43, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 42, 48

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_66_n71

E-UTRA Band 4, 5, 13, 14, 17, 24, 26, 27, 29, 30, 43, 50, 51, 66, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 7, 22, 25, 41, 42, 48, 70

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 71

FDL_low

FDL_high

-50

1

5

DC_66_n78,

DC_66_n86_ULSUP-TDM_n78

E-UTRA Band 1, 3, 5, 7, 8, 20, 26, 28, 34, 39, 40, 41, 65

FDL_low

FDL_high

-50

1

NOTE 1: FDL_low and FDL_high refer to each frequency band specified in Table 5.5-1 in TS 36.101 [5] or in Table 5.2-1 in TS 38.101-1 [2].

NOTE 2: As exceptions, measurements with a level up to the applicable requirements defined in Table 6.6.3.1-2 in TS 36.101 [5] and Table 6.5.3.1-2 in TS 38.101-1 [2] are permitted for each assigned carrier used in the measurement due to 2nd, 3rd, 4th or 5th harmonic spurious emissions. Due to spreading of the harmonic emission the exception is also allowed for the first 1 MHz frequency range immediately outside the harmonic emission on both sides of the harmonic emission. This results in an overall exception interval centred at the harmonic emission of (2 MHz + N x LCRB x 180 kHz), where N is 2, 3, 4, 5 for the 2nd, 3rd, 4th or 5th harmonic respectively. The exception is allowed if the measurement bandwidth (MBW) totally or partially overlaps the overall exception interval.

NOTE 3: Applicable when co-existence with PHS system operating in 1884.5 – 1915.7 MHz

NOTE 4: Void.

NOTE 5: These requirements also apply for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1, Table 6.6.3.1A-1 in TS 36.101 [5] or in Table 6.5.3.1-1 in TS 38.101-1 [2] from the edge of the channel bandwidth.

NOTE 6: This requirement is applicable for any channel bandwidths within the range 2500 – 2570 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 2560.5 – 2562.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 2552 – 2560 MHz the requirement is applicable only for an uplink transmission bandwidth less than or equal to 54 RB.

NOTE 7: For these adjacent bands, the emission limit could imply risk of harmful interference to UE(s) operating in the protected operating band.

NOTE 8: This requirement is applicable for any channel bandwidths within the range 1920 – 1980 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 1927.5 – 1929.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 1930 – 1938 MHz the requirement is applicable only for an uplink

NOTE 9: Applicable when the assigned E-UTRA or NR carrier is confined within 718 MHz and 748 MHz and when the channel bandwidth used is 5 or 10 MHz.

NOTE 10: As exceptions, measurements with a level up to the applicable requirement of -38 dBm/MHz is permitted for each assigned E-UTRA carrier used in the measurement due to 2nd harmonic spurious emissions. An exception is allowed if there is at least one individual RB within the transmission bandwidth (see Figure 5.6-1) for which the 2nd harmonic totally or partially overlaps the measurement bandwidth (MBW).

NOTE 11: As exceptions, measurements with a level up to the applicable requirement of -36 dBm/MHz is permitted for each assigned E-UTRA carrier used in the measurement due to 3rd harmonic spurious emissions. An exception is allowed if there is at least one individual RB within the transmission bandwidth (see Figure 5.6-1) for which the 3rd harmonic totally or partially overlaps the measurement bandwidth (MBW).

NOTE 12: This requirement is applicable only for the following cases: A: for carriers of 5 MHz channel bandwidth when carrier centre frequency (Fc) is within the range 902.5 MHz ≤ Fc < 907.5 MHz with an uplink transmission bandwidth less than or equal to 20 RB; B: for carriers of 5 MHz channel bandwidth when carrier centre frequency (Fc) is within the range 907.5 MHz ≤ Fc ≤ 912.5 MHz without any restriction on uplink transmission bandwidth; C: for carriers of 10 MHz channel bandwidth when carrier centre frequency (Fc) is Fc = 910 MHz with an uplink transmission bandwidth less than or equal to 32 RB with RBstart > 3.

NOTE 13: Void.

NOTE 14: This requirement is applicable for 5 and 10 MHz E-UTRA or NR channel bandwidth allocated within 718-728MHz. For carriers of 10 MHz bandwidth, this requirement applies for an uplink transmission bandwidth less than or equal to 30 RB with RBstart > 1 and RBstart < 48.

NOTE 15: Void.

NOTE 16: This requirement is applicable for any channel bandwidths within the range 1920 – 1980 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 1927.5 – 1929.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 1930 – 1938 MHz the requirement is applicable only for an uplink transmission bandwidth less than or equal to 54 RB.

NOTE 17: This requirement is applicable in the case of a 10 MHz E-UTRA or NR carrier confined within 703 MHz and 733 MHz, otherwise the requirement of -25 dBm with a measurement bandwidth of 8 MHz applies.

NOTE 18: This requirement is only applicable for E-UTRA carriers with bandwidth confined within 1885 – 1920 MHz (requirement for carriers with at least 1RB confined within 1880 – 1885 MHz is not specified). This requirement applies for an uplink transmission bandwidth less than or equal to 54 RB for E-UTRA carriers of 15 MHz bandwidth when carrier centre frequency is within the range 1892.5 – 1894.5 MHz and for E-UTRA carriers of 20 MHz bandwidth when carrier centre frequency is within the range 1895 – 1903 MHz.

NOTE 19: Void.

NOTE 20: Void.

NOTE 21: Void.

NOTE 22: This requirement is applicable for power class 3 UE for any channel bandwidths within the range 2570 – 2615 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 2605.5 – 2607.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 2597 – 2605 MHz the requirement is applicable only for an uplink transmission bandwidth less than or equal to 54 RB.

Table 6.5B.3.3.2.3-3: Spurious emission band UE co-existence limits Rel-17

EN-DC Configuration

Spurious emission

Protected band

Frequency range (MHz)

Maximum Level (dBm)

MBW (MHz)

NOTE

DC_1_n3

E-UTRA Band 1, 5, 7, 8, 11, 18, 19, 20, 21, 26, 27, 28, 31, 32, 38, 40, 41, 43, 44, 50, 51, 65, 67, 72, 73, 74, 75, 76

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA band 3, 34

FDL_low

FDL_high

-50

1

5

E-UTRA band 22, 42, 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

1880

1895

-40

1

5, 67

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

DC_1_n5

E-UTRA Band 1, 5, 7, 8, 11, 18, 19, 21, 22, 26, 28, 31, 38, 40, 42, 43, 50, 51, 65, 73, 74

FDL_low

FDL_high

-50

1

E-UTRA band 3,34

FDL_low

FDL_high

-50

1

5

E-UTRA band 41, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

DC_1_n7

E-UTRA Band 1, 5, 7, 8, 20, 22, 26, 27, 28, 31,32, 40, 42, 43, 50, 51, 52, 65, 67, 72, 74, 75, 76

NR Band n78, n79

FDL_low

FDL_high

-50

1

band n77

FDL_low

FDL_high

-50

1

2

band 3, 34

FDL_low

FDL_high

-50

1

5

Frequency range

1880

1895

-40

1

5,16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_1_n8

E-UTRA Band 11, 20, 21, 28, 31, 32, 38, 40, 45, 50, 51, 65, 67, 68, 69, 72, 73, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA band 3, 7, 22, 41, 42, 43, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1, 8, 34

FDL_low

FDL_high

-50

1

5

Frequency range

1880

1895

-40

1

5, 16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

DC_1_n20

E-UTRA Band 1, 3, 7, 8, 22, 31, 32, 40, 43, 50, 51, 65, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 38, 42, 69

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA Band 20, 34

FDL_low

FDL_high

-50

1

5

Frequency range

758

788

-50

1

DC_1_n28

E-UTRA Band 5, 7, 8, 18, 19, 20, 26, 27, 31, 38, 40, 41, 72, 73

NR band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 22, 32, 42, 43, 50, 51, 52, 65, 74, 75, 76

NR band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA band 3, 34

FDL_low

FDL_high

-50

1

5

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 1, 65

FDL_low

FDL_high

-50

1

9, 10

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

662

694

-26.2

6

5

Frequency range

1880

1895

-40

1

5,16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

DC_1_n38

E-UTRA Band 1, 3, 5, 8, 20, 22, 27, 28, 31, 32, 34, 40, 42, 43, 50, 51, 65, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

DC_1_n40

E-UTRA Band 1, 5, 7, 8, 11, 18, 19, 20, 21, 22, 26, 27, 28, 31, 32, 38, 41, 42, 43, 44, 45, 50, 51, 52, 65, 67, 68, 69, 72, 73, 74, 75, 76

NR band n78

FDL_low

FDL_high

-50

1

Band 3, 34

FDL_low

FDL_high

-50

1

5

NR band n77, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1880

1895

-40

1

5, 16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

Frequency range

1884.5

1915.7

-41

0.3

3

DC_1_n41

E-UTRA Band 3, 4, 5, 8, 12, 13, 14, 17, 19, 20, 21, 24, 26, 27, 28, 29, 30, 31, 32, 42, 43, 44, 45, 50, 51, 52, 66, 67, 68, 71, 72, 73, 75, 76, 85

NR Band n78

FDL_low

FDL_high

-50

1

E-UTRA Band 34

FDL_low

FDL_high

-50

1

5

NR Band n77, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 40

FDL_low

FDL_high

-40

1

Frequency range

1880

1895

-40

1

5, 8

Frequency range

1895

1915

-15.5

5

5, 7, 8

Frequency range

1915

1920

+1.6

5

5, 7, 8, 20

E-UTRA Band 11, 18, 19, 21, 74

FDL_low

FDL_high

-50

1

DC_1A_n50A

E-UTRA Band 3, 4, 5, 7, 8, 12, 13, 17, 18, 19, 20, 26, 27, 28, 29, 31, 38, 40, 41, 42, 43, 44, 48, 52, 66, 67, 68, 69, 72, 73, 85

NR Band n78

FDL_low

FDL_high

-50

1

E-UTRA Band 34

FDL_low

FDL_high

-50

1

5

NR Band n77, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1880

1895

-40

1

5,16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

DC_1_n51

E-UTRA Band 7, 12, 13, 17, 20, 22, 27, 28, 29, 31, 38, 44, 48, 67, 68, 69, 72, 73

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 34

FDL_low

FDL_high

-50

1

5, 2

Frequency range

1880

1895

-40

1

5, 16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

E-UTRA Band 5, 6, 8, 26, 30, 40, 41, 42, 43, 46

NR Band n77, n78, n79,

FDL_low

FDL_high

-50

1

2

DC_1_n71

E-UTRA Band 1, 5, 26,

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

E-UTRA Band 71

FDL_low

FDL_high

-50

1

5

DC_1_n77

DC_1_n84_ULSUP-TDM_n77

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 20, 21, 26, 28, 34, 40, 41, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

1880

1895

-40

1

5, 8

Frequency range

1895

1915

-15.5

5

5, 7, 8

Frequency range

1915

1920

+1.6

5

5, 7, 8

DC_1_n78

DC_1_n84_ULSUP-TDM_n78

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 20, 21, 26, 28, 34, 40, 41, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

1880

1895

-40

1

5, 8

Frequency range

1895

1915

-15.5

5

5, 7, 8

Frequency range

1915

1920

+1.6

5

5, 7, 8

DC_1_n79

DC_1_n84_ULSUP-TDM_n79

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 21, 26, 28, 34, 40, 41, 42, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

1880

1895

-40

1

5, 8

Frequency range

1895

1915

-15.5

5

5, 7, 8

Frequency range

1915

1920

+1.6

5

5, 7, 8

DC_1_n80

E-UTRA Band 1, 5, 7, 8, 11, 18, 19, 20, 21, 26, 27, 28, 31, 32, 38, 40, 41, 43, 44, 45, 50, 51, 65, 67, 68, 69, 72, 73,74, 75, 76,

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 34

FDL_low

FDL_high

-50

1

5

E-UTRA Band 22, 42,

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

DC_2_n5

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 28, 29, 30, 42, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

2, 5

E-UTRA Band 2, 25, 48

FDL_low

FDL_high

-50

1

2

E-UTRA Band 41, 43, 53

FDL_low

FDL_high

-50

1

2

DC_2_n7

E-UTRA Band 2, 4, 5, 7, 12, 13, 14, 17, 26, 27, 28, 29, 30, 42, 50, 51, 66, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 43

FDL_low

FDL_high

-50

1

2

Frequency range

2570

2575

1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_2_n12

E-UTRA Band 5, 13, 14, 17, 24, 26, 27, 30, 41, 50, 53, 71, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 25, 85

NR band n12

FDL_low

FDL_high

-50

1

3

E-UTRA Band 2

FDL_low

FDL_high

-50

1

5

E-UTRA Band 4, 51, 66, 70,

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_2_n28

E-UTRA Band 5, 26, 27, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 10, 42, 43, 50, 51, 66, 74

FDL_low

FDL_high

-50

1

2

E-UTRA band 2, 25

FDL_low

FDL_high

-50

1

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 1, 65

FDL_low

FDL_high

-50

1

9, 10

Frequency range

470

710

-26.2

6

14

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

2570

2575

1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_2_n30

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 27, 29, 30, 41, 48, 53, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

5

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_2_n38

E-UTRA Band 4, 5, 12, 13, 14,17, 27, 28, 29, 30, 42, 50, 51, 66, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 2

FDL_low

FDL_high

-50

1

5

E-UTRA Band 43

FDL_low

FDL_high

-50

1

2

DC_2_n41

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 27, 28, 29, 30, 42, 48, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

5

E-UTRA Band 43,

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_2A_n48A

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 29, 30, 41, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

5

DC_2_n66

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 27, 28, 29, 30, 41, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

5

E-UTRA Band 42, 48,

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_2_n71

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 29, 30, 48, 66

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25, 41, 70,

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 71

FDL_low

FDL_high

-50

1

5

DC_2_n77

E-UTRA Band 4, 5, 12, 13, 14, 17, 26, 29, 30, 41, 65, 66, 70, 71

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

2

DC_2_n78

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 27, 28, 29, 30, 41, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

2

DC_3_n1

E-UTRA Band 1, 5, 7, 8, 11, 18, 19, 20, 21, 26, 27, 28, 31, 32, 38, 40, 41, 43, 44, 50, 51, 65, 67, 72, 73, 74, 75, 76

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA band 3, 34

FDL_low

FDL_high

-50

1

5

E-UTRA band 22, 42, 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

1880

1895

-40

1

5,16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

DC_3_n5

E-UTRA Band 1, 5, 7, 8, 11, 18, 19, 21, 26, 28, 31, 38, 40, 43, 50, 51, 65, 73, 74

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA band 3,34

FDL_low

FDL_high

-50

1

5

E-UTRA Band 22, 42, 52

Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n7

E-UTRA Band 1, 5, 7, 8, 20, 26, 27, 28, 31, 32, 33, 34, 40, 43, 44, 50, 51, 65, 67, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA band 3

FDL_low

FDL_high

-50

1

5

E-UTRA band 22, 42

FDL_low

FDL_high

-50

1

2

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_3_n8

E-UTRA Band 1, 11, 20, 21, 28, 31, 32, 33, 34, 38, 39, 40, 45, 50, 51, 65, 67,68, 69, 72, 73, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA band 3, 8

FDL_low

FDL_high

-50

1

2, 5

E-UTRA band 7, 22, 41, 42, 43, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n20

E-UTRA Band 1, 7, 8, 31, 32, 33, 34, 40, 43, 50, 51, 65, 67, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 3

NR band n20

FDL_low

FDL_high

-50

1

5

E-UTRA Band 22, 38, 42, 52

FDL_low

FDL_high

-50

1

2

Frequency range

758

788

-50

1

DC_3_n28

E-UTRA Band 1, 42, 43, 50, 51, 65, 74, 75, 76

NR band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA band 1

FDL_low

FDL_high

-50

1

9, 11

E-UTRA band 3

FDL_low

FDL_high

-50

1

5

E-UTRA Band 5, 7, 8, 18, 19, 20, 26, 27, 31, 34, 38, 40, 41, 72

FDL_low

FDL_high

-50

1

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 10

Frequency range

1884.5

1915.7

-41

0.3

13

Frequency range

470

710

-26.2

6

14

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3, 9

DC_3_n34

E-UTRA Band 1, 7, 8, 11, 18, 19, 20, 21, 26, 28, 31, 32, 33, 38, 39, 40, 41, 43, 44, 45, 50, 51, 65, 67, 69,72, 73, 74, 75, 76, 79

FDL_low

FDL_high

-50

1

E-UTRA Band 22, 42, 52

NR Band n78

FDL_low

FDL_high

-50

1

2

E-UTRA Band 3

FDL_low

FDL_high

-50

1

5

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n38

E-UTRA Band 1, 5, 8, 20, 27, 28, 31, 32, 33, 34, 40, 43, 50, 51, 65, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 22, 42

FDL_low

FDL_high

-50

1

2

DC_3_n40

E-UTRA Band 1, 5, 7, 8, 11, 18, 19, 20, 21, 26, 27, 28, 31, 32, 33, 34, 38, 39, 41, 43, 44. 45, 50, 51, 65, 67, 68, 69, 72, 73, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 3

FDL_low

FDL_high

-50

1

5

E-UTRA Band 22, 42, 52

NR band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n41,

DC_3_n80_ULSUP-TDM_n41

E-UTRA Band 1, 5, 8, 11, 18, 19, 21, 26, 27, 28, 34, 39, 44, 45, 50, 51, 65, 73, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 42, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 40

FDL_low

FDL_high

-40

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n50

E-UTRA Band 5, 7, 8, 12, 13, 17, 18, 19, 20, 26, 27, 28, 29, 31, 38, 40, 41, 43, 44, 52, 67, 68, 69, 72, 73

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 2, 4, 33, 34, 39, 42, 48, 65, 66

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

DC_3_n51

E-UTRA Band 7, 8, 12, 13, 17, 20, 27, 28, 31, 33, 38, 67, 68, 69, 72, 73

FDL_low

FDL_high

-50

1

E-UTRA Band 3

FDL_low

FDL_high

-50

1

5

E-UTRA Band 1, 5, 6, 22, 26, 30, 34, 36, 40, 41, 42, 43, 44, 46, 48, 65, 71

FDL_low

FDL_high

-50

1

2

DC_3_n71

E-UTRA Band 5, 26,

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

E-UTRA Band 3, 71

FDL_low

FDL_high

-50

1

5

DC_3_n77

DC_3_n80_ULSUP-TDM_n77

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 20, 21, 26, 28, 34, 39, 40, 41, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n78

DC_3_n80_ULSUP-TDM_n78

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 20, 21, 26, 28, 34, 39, 40, 41, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n79 DC_3_n80_ULSUP-TDM_n79

E-UTRA Band 1, 3, 5, 8, 11, 18, 19, 21, 28, 34, 39, 40, 41, 65, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 42

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n82

E-UTRA Band 1, 3 7, 8, 20,31, 32, 33, 34, 40, 43, 50, 51, 65, 67, 68, 72,74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 22, 38, 42, 69

FDL_low

FDL_high

-50

1

2

DC_3_n84

E-UTRA Band 1, 5, 7, 8, 11, 18, 19, 20, 21, 26, 27, 28, 31, 32, 38, 40, 41, 43, 44, 45, 50, 51, 65, 67, 68, 69, 72, 73,74, 75, 76

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 3

FDL_low

FDL_high

-50

1

5

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

DC_4_n2

E-UTRA Band 4, 5, 10, 12, 13, 14, 17, 22, 24, 26, 27, 28, 29, 30, 41, 50, 51, 53, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

5

E-UTRA Band 42, 43,

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

DC_4_n5

Bands 1, 2, 3, 4, 5, 6, 7, 8, 10, 12, 13, 14, 17, 24, 25, 28, 29, 30, 34, 38, 40, 43, 45, 50, 51, 65, 66, 70, 71, n71, 85, n257

FDL_low

FDL_high

-50

1

E-UTRA Band 26

859

869

-27

1

Bands 41, 42, 48, 52

FDL_low

FDL_high

-50

1

2

E-UTRA Band 18, 19

FDL_low

FDL_high

-40

1

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_4_n7

E-UTRA Band 2, 4, 5, 7, 10, 12, 13, 14, 17, 26, 27, 28, 29, 30, 43, 50, 51, 66, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 42

FDL_low

FDL_high

-50

1

2

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

DC_4_n28

E-UTRA Band 2, 5, 7, 25, 26, 27, 38, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 10, 42, 43, 50, 51, 66, 74,

NR band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

Frequency range

662

694

-26.2

6

5

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

DC_4_n38

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 27, 28, 29, 30, 43, 50, 51, 66, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 42

FDL_low

FDL_high

-50

1

2

DC_4_n41

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 26, 27, 28, 29, 30, 48, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 42, 48

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_4_n78

E-UTRA Band 5, 7, 26, 28, 41

FDL_low

FDL_high

-50

1

DC_5_n2

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 28, 29, 30, 42, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 25

FDL_low

FDL_high

-50

1

5

NR Band n2

FDL_low

FDL_high

-50

1

5

E-UTRA Band 26

859

869

-27

1

E-UTRA Band 41, 43, 53

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_5_n7

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 12, 13, 14, 17, 28, 29, 30, 31, 34, 40, 42, 43, 65, 66, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA band 26

859

869

-27

1

Frequency range

2570

2575

+1.6

5

5, 7, 6

Frequency range

2575

2595

-15.5

5

5, 7, 6

Frequency range

2595

2620

-40

1

5, 14

DC_5_n12

E-UTRA Band 2, 5, 13, 14, 17, 24, 25, 26, 30, 43, 50, 71, 74

FDL_low

FDL_high

-50

1

E-UTRA Bands 4, 41, 42, 48, 51, 66, 70,

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 12, 85

FDL_low

FDL_high

-50

1

5

DC_5_n30

E-UTRA Band 2, 4, 5, 7,12, 13, 14, 17, 24, 25, 26, 29, 30, 38, 48, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 41, 53

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_5_n38

E-UTRA Band 1, 2, 3, 4, 5, 8, 12, 13, 14, 17, 28, 29, 30, 31, 34, 40, 42, 43, 50, 51, 65, 66, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 52

FDL_low

FDL_high

-50

1

2

DC_5_n40

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 21, 28, 31, 34, 38, 42, 43, 45, 65, 73, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 26

859

869

-27

1

E-UTRA Band 41, 52

NR band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_5_n48

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 29, 30, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 26

859

869

-27

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

DC_5_n66

E-UTRA Band 1, 2, 3, 4, 5, 6, 7, 8, 12, 13, 14, 17, 24, 25, 28, 29, 30, 34, 38, 40, 43, 45, 50, 51, 65, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 26

859

869

-27

1

E-UTRA Band 41, 42, 48, 52,

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_5_n71

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 30, 48, 66, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25, 41, 70,

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 29

FDL_low

FDL_high

-38

1

5

E-UTRA Band 71

FDL_low

FDL_high

-50

1

5

DC_5_n77

E-UTRA Band 2, 4, 12, 13, 14, 17, 25, 26, 28, 29, 30, 40, 65, 66, 70, 71

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_5_n78

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 12, 13, 14, 17, 24, 25, 28, 29, 30, 31, 34, 38, 40, 45, 65, 66, 70

FDL_low

FDL_high

-50

1

E-UTRA Band 26

859

869

-27

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2, 7

DC_5_n79

Bands 1, 2, 3, 4, 5, 7, 8, 12, 13, 14, 17, 24, 25, 28, 29, 30, 31, 34, 38, 40, 42, 43, 45, 48, 50, 51, 65, 66, 70, 71, 73, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 26

859

869

-27

1

Bands 41, 52

FDL_low

FDL_high

-50

1

2

DC_7_n1

Band 1, 5, 7, 8, 20, 22, 26, 27, 28, 31,32, 40, 42, 43, 50, 51, 52, 65, 67, 72, 74, 75, 76, n78,n79

FDL_low

FDL_high

-50

1

band n77

FDL_low

FDL_high

-50

1

2

band 3, 34

FDL_low

FDL_high

-50

1

5

Frequency range

1880

1895

-40

1

5,16

Frequency range

1895

1915

-15.5

5

5, 7,16

Frequency range

1915

1920

+1.6

5

5, 7,16

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_7_n2

E-UTRA Band 4, 5, 7, 10, 12, 13, 14, 17, 26, 27, 28, 29, 30, 42, 50, 51, 66, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 43

FDL_low

FDL_high

-50

1

2

E-UTRA band 2

FDL_low

FDL_high

-50

1

Frequency range

2570

2575

1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_7_n3

E-UTRA Band 1, 5, 7, 8, 20, 26, 27, 28, 31, 32, 33, 34, 40, 43, 50, 51, 65, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA band 3

FDL_low

FDL_high

-50

1

5

E-UTRA band 22, 42, 52

NR band n78, n77

FDL_low

FDL_high

-50

1

2

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_7_n5

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 12, 13, 14, 17, 22, 26, 28, 29, 30, 31, 40, 42, 43, 50, 51, 65, 66, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

2570

2575

+1.6

5

5, 7, 6

Frequency range

2575

2595

-15.5

5

5, 7, 6

Frequency range

2595

2620

-40

1

5, 14

DC_7_n8

E-UTRA Band 1, 20, 28, 31, 32, 33, 34, 40, 50, 51, 65, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA band 3, 7, 22, 42, 43, 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_7_n20

E-UTRA Band 1, 3, 7, 8, 22, 31, 32, 33, 34, 40, 43, 50, 51, 65, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 42, 52

NR band n78, n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 20

FDL_low

FDL_high

-50

1

5

DC_7_n25

E-UTRA Band 4, 5, 12, 13, 14, 17, 26, 27, 28, 29, 30, 42, 66, 71, 85

NR Band n77

FDL_low

FDL_high

-50

1

E-UTRA Band 43

FDL_low

FDL_high

-50

1

2

E-UTRA Band 2
NR Band n25

FDL_low

FDL_high

-50

1

5

Frequency range

2570

2575

1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_7_n28

E-UTRA Band 2, 3, 5, 7, 8, 20, 26, 27, 31, 34, 40, 72

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 4, 42, 43, 50, 51, 65, 66, 74, 75, 76

NR band n78

FDL_low

FDL_high

-50

1

2

E-UTRA band 1

FDL_low

FDL_high

-50

1

9, 10

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_7_n40

E-UTRA Band 1, 3, 5, 7, 8, 20, 22, 26, 27, 28, 31, 32, 33, 34, 42, 43, 50, 51, 52, 65, 67, 68, 72, 74, 75, 76, 77, 78

FDL_low

FDL_high

-50

1

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_7_n51

E-UTRA Band 2, 3, 5, 8, 26, 30, 31, 32, 33, 34, 40, 48, 72

FDL_low

FDL_high

-50

1

Frequency range

2570

2575

+1.6

5

5, 7, 16

Frequency range

2575

2595

-15.5

5

5, 7, 16

Frequency range

2595

2620

-40

1

5

E-UTRA Band 1, 4, 12, 13, 14, 17, 20, 22, 23, 27, 28, 29, 42, 43, 44, 46, 65, 66, 67, 68

NR Band n77, n78, n79,

FDL_low

FDL_high

-50

1

2

DC_7_n66

E-UTRA Band 2, 4, 5, 7, 12, 13, 14, 17, 26, 27, 28, 29, 30, 43, 50, 51, 66, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 42

FDL_low

FDL_high

-50

1

2

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_7_n71

E-UTRA Band 4, 5, 12, 13, 14, 17, 26, 30, 66, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 70

FDL_low

FDL_high

-50

1

2

E-UTRA Band 29

FDL_low

FDL_high

-38

1

5

Frequency range

2570

2575

1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_7_n77

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 11, 18, 19, 20, 21, 26, 27, 28, 31, 32, 33, 34, 40, 50, 51, 65, 66, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_7_n78

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 11, 18, 19, 20, 21, 26, 27, 28, 31, 32, 33, 34, 40, 50, 51, 65, 66, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_7_n79

E-UTRA Band 1, 3, 5, 8, 28, 34, 40, 42, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_8_n1

E-UTRA Band 20, 28, 31, 32, 38, 40, 50, 51, 65, 67, 72, 73, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA band 3, 7, 22, 41, 42, 43, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1, 8, 34

FDL_low

FDL_high

-50

1

5

E-UTRA band 11, 21

FDL_low

FDL_high

-50

1

12

Frequency range

860

890

-40

1

5, 12

Frequency range

1880

1895

-40

1

5, 16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

DC_8_n2

E-UTRA Band 2, 8, 28, 50, 51, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 41, 42, 43

FDL_low

FDL_high

-50

1

2

DC_8_n3

E-UTRA Band 1, 20, 28, 31, 32, 33, 34, 38, 39, 40, 44, 50, 51, 65, 67, 72, 73, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA band 3, 8

FDL_low

FDL_high

-50

1

2, 5

E-UTRA band 11, 21

FDL_low

FDL_high

-50

1

12

E-UTRA band 7, 22, 41, 42, 43, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3.12

Frequency range

860

890

-40

1

5. 12

DC_8_n7

E-UTRA Band 1, 2, 3, 4, 5, 7, 8, 10, 12, 13, 14, 17, 20, 22, 26, 27, 28, 29, 30, 31, 32, 33, 34, 40, 42, 43, 45, 50, 51, 52, 65, 66, 67, 68, 69, 72, 73, 74, 75, 76, 85,

FDL_low

FDL_high

-50

1

E-UTRA band 3, 7, 22, 41, 42, 43, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

12

Frequency range

860

890

-40

1

5, 12

Frequency range

1884.5

1915.7

-41

0.3

3, 12

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_7_n80

E-UTRA Band 1, 5, 7, 8, 20, 26, 27, 28, 31, 32, 33, 34, 40, 43, 50, 51, 65, 67, 68, 72, 74, 75, 76.

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 3

FDL_low

FDL_high

-50

1

5

E-UTRA Band 22, 42,

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_8_n20

E-UTRA Band 1, 31, 32, 33, 34, 40, 50, 51, 65, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 7, 22, 38, 42, 43, 52, 69

NR band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8, 20

FDL_low

FDL_high

-50

1

5

Frequency range

758

788

-50

1

DC_8_n28

E-UTRA Band 20, 31, 34, 38, 40, 72

FDL_low

FDL_high

-50

1

E-UTRA band 3, 7, 22, 41, 42, 43, 50, 51, 65, 73, 74, 75, 76

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

2, 9, 11

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 10, 12

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

Frequency range

662

694

-26.2

6

5

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

860

890

-40

1

5, 12

Frequency range

1884.5

1915.7

-41

0.3

3, 9, 12

DC_8_n34

E-UTRA Band 1, 20, 28, 31, 32, 33, 38, 39, 40, 45, 50, 51, 65, 67, 69,72, 73, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 7, 22, 41, 42, 43, 52

NR Band n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

12

Frequency range

1884.5

1915.7

-41

0.3

3, 12

Frequency range

860

890

-40

1

5, 12

DC_8_n39

E-UTRA Band 1, 28, 34, 40, 45, 50, 51, 73, 74

FDL_low

FDL_high

-50

1

UTRA Band 22, 41, 42, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

DC_8_n40

E-UTRA Band 1, 5, 11, 18, 19, 20, 21, 26, 28, 31, 32, 33, 34, 38, 39,, 45, 50, 51, 65, 67, 68, 69, 72, 73, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 7, 22, 41, 42, 43, 52

NR band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

Frequency range

1884.5

1915.7

-41

0.3

3

DC_8_n41,

DC_8_n81_ULSUP-TDM_n41

E-UTRA Band 1, 11, 21, 28, 34, 39, 45, 50, 51, 65, 73, 74

FDL_low

FDL_high

-50

1

E-UTRA band 3, 42, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

E-UTRA Band 40

FDL_low

FDL_high

-40

1

Frequency range

860

890

-40

1

5, 12

Frequency range

1884.5

1915.7

-41

0.3

3

DC_8_n77

E-UTRA Band 1, 20, 28, 31, 32, 33, 34, 38, 39, 40, 44, 45, 50, 51, 65, 67, 68, 69, 72, 73, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA band 3, 7, 41

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

12

Frequency range

860

890

-40

1

5, 12

Frequency range

1884.5

1915.7

-41

0.3

3, 12

DC_8_n78

DC_8_n81_ULSUP-TDM_n78

E-UTRA Band 1, 20, 28, 34, 39, 40, 65, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 7, 41

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

12

Frequency range

860

890

-40

1

5, 12

Frequency range

1884.5

1915.7

-41

0.3

3, 12

DC_8_n79

DC_8_n81_ULSUP-TDM_n79

E-UTRA Band 1, 8, 28, 34, 39, 40, 65, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 3,41,42

FDL_low

FDL_high

-50

1

2

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

12

Frequency range

860

890

-40

1

5, 12

Frequency range

1884.5

1915.7

-41

0.3

3

DC_8_n80

E-UTRA Band 1, 20, 28, 31, 32, 33, 34, 38, 39, 40, 45, 50, 51, 65, 67, 68, 69, 72, 73, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 8

FDL_low

FDL_high

-50

1

5

E-UTRA Band 3, 7, 22, 41, 42, 43, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

13

Frequency range

1884.5

1915.7

-41

0.3

3

DC_8A_93A_ULSUP-TDM,

DC_8A_94A_ULSUP-TDM

E-UTRA Band 1, 20, 28, 31, 32, 33, 34, 38, 39, 40, 45, 50, 51, 52, 65, 67, 68, 69, 72, 73, 74, 75, 76

FDL_low

FDL_high

-50

-50

1

1

E-UTRA band 3, 7, 22, 41, 42, 43

NR Band n77, n78

FDL_low

FDL_high

-50

1

2, 5

E-UTRA 8

FDL_low

FDL_high

-50

1

2

DC_11_n3

E-UTRA Band 1, 11, 18, 19, 21, 28, 34, 40, 65

NR band n79

FDL_low

FDL_high

-50

1

E-UTRA band 3

FDL_low

FDL_high

-50

1

5

E-UTRA Band 42

NR band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_11_n28

E-UTRA Band 3, 18, 19, 34, 40

NR band n79

FDL_low

FDL_high

-50

1

E-UTRA band 42, 65, 74

NR band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA band 1

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 10

Frequency range

470

710

-26.2

6

14

Frequency range

773

803

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3, 9

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_11_n41

E-UTRA Band 1, 3, 11, 18, 19, 21, 28, 34, 42, 65

NR Band n77, n78

FDL_low

FDL_high

-50

1

NR Band n79

FDL_low

FDL_high

-50

1

2

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_11_n77

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_11_n78

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_11_n79

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 42, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_12_n2

E-UTRA Band 5, 13, 14, 17, 24, 26, 27, 30, 41, 50, 53, 71, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 12, 25, 85

FDL_low

FDL_high

-50

1

3

E-UTRA Band 2

FDL_low

FDL_high

-50

1

5

E-UTRA Band 4, 51, 66, 70,

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_12_n5

E-UTRA Band 2, 5, 13, 14, 17, 24, 25, 26, 30, 43 50, 71, 74

FDL_low

FDL_high

-50

1

E-UTRA Bands 4, 41, 42, 48, 51, 66, 70,

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 12, 85

FDL_low

FDL_high

-50

1

DC_12_n66

E-UTRA Band 2, 5, 13, 14, 17, 25, 26, 27, 30, 41, 53, 71, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 48, 50, 51, 66, 70

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 12, 85

FDL_low

FDL_high

-50

1

5

DC_12_n7

E-UTRA Band 2, 5, 7, 13, 14, 17, 26, 27, 30, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 50, 51,66

NR Band n78

FDL_low

FDL_high

-50

1

2

E-UTRA Band 12, 85

FDL_low

FDL_high

-50

1

5

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_12_n25

E-UTRA Band 5, 13, 14, 17, 24, 26, 27, 30, 41, 53, 71

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 48, 66, 70.

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 2, 12, 25, 85

FDL_low

FDL_high

-50

1

15

DC_12_n30

E-UTRA Band 2, 5, 13, 14, 17, 24, 25, 26, 27, 30, 41, 48, 53, 71

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 66, 70,

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 12, 85

FDL_low

FDL_high

-50

1

5

DC_12_n38

E-UTRA Band 2, 5, 13. 14. 17, 27, 30, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 50, 51, 66

FDL_low

FDL_high

-50

1

2

E-UTRA band 12, 85

FDL_low

FDL_high

-50

1

5

DC_12_n41

E-UTRA Band 2, 5, 13, 14, 17, 24, 25, 26, 27, 30, 71, 74

FDL_low

FDL_high

-50

1

E-UTRA band 4, 48, 50, 51, 66, 70

FDL_low

FDL_high

-50

1

2

E-UTRA band 12, 85

FDL_low

FDL_high

-50

1

5

DC_12_n77

E-UTRA Band 2, 5, 7. 13, 17, 24, 25, 26, 27, 30, 41, 53, 70, 71

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 66

FDL_low

FDL_high

-50

1

2

E-UTRA band 12, 85

FDL_low

FDL_high

-50

1

5

DC_12_n78

E-UTRA Band 2, 5, 7. 13, 17, 25, 26, 41, 71

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 66

FDL_low

FDL_high

-50

1

2

E-UTRA band 12

FDL_low

FDL_high

-50

1

5

Frequency range

1884.5

1915.7

-41

0.3

3

DC_13_n2

E-UTRA Band 4, 5,12,13,17, 26, 29, 41, 48, 66, 70, 71

FDL_low

FDL_high

-50

1

E-UTRA Band 2,14, 25

FDL_low

FDL_high

-50

1

5

E-UTRA Band 30

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

5

Frequency range

799

805

-35

0.00625

5

DC_13_n5

E-UTRA Band 2, 4, 5, 12, 13, 17, 25, 29, 48, 50, 51, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 26

859

869

-27

1

E-UTRA Band 24, 30, 41, 53

FDL_low

FDL_high

-50

1

2

E-UTRA Band 14

FDL_low

FDL_high

-50

1

5

Frequency range

769

775

-35

0.00625

5

Frequency range

799

805

-35

0.00625

5

DC_13_n7

E-UTRA Band 2, 4, 5, 7, 12, 13, 17,25,26, 27, 29, 50, 51, 66,74, 85

NR Band n78

FDL_low

FDL_high

-50

1

E-UTRA Band 30

FDL_low

FDL_high

-50

1

2

E-UTRA Band 14

FDL_low

FDL_high

-50

1

5

Frequency range

769

775

-35

0.00625

5

Frequency range

799

805

-35

0.00625

5

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_13_n25

E-UTRA Band 4, 5,12,13,17, 26, 29, 41, 48, 66, 70, 71

FDL_low

FDL_high

-50

1

E-UTRA Band 2,14
NR Band n25

FDL_low

FDL_high

-50

1

5

E-UTRA Band 30

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

5

Frequency range

799

805

-35

0.00625

5

DC_13_n48

E-UTRA Band 2, 4, 5, 12, 13, 17, 25, 26, 27, 29, 41, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 14

FDL_low

FDL_high

-50

1

5

E-UTRA Band 24, 30

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

5

Frequency range

799

805

-35

0.00625

5

DC_13_n66

E-UTRA Band 2, 4, 5, 12, 13, 17, 25, 26, 27, 29, 41, 50, 51, 53, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 14

FDL_low

FDL_high

-50

1

5

E-UTRA Band 30, 48,

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

5

Frequency range

799

803

-35

0.00625

5

DC_13_n71

E-UTRA Band 4, 5, 12, 13, 17, 26, 48, 66, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 24, 25, 30, 41, 70,

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 29

FDL_low

FDL_high

-38

1

5

E-UTRA Band 14, 71

FDL_low

FDL_high

-50

1

5

Frequency range

769

775

-35

0.00625

5

Frequency range

799

805

-35

0.00625

5

DC_13_n77

E-UTRA Band 2, 4, 5, 10, 12, 13, 17, 25, 26, 29, 41, 66, 70, 71

FDL_low

FDL_high

-50

1

E-UTRA Band 14

FDL_low

FDL_high

-50

1

5

E-UTRA Band 24, 30

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

5

Frequency range

799

805

-35

0.00625

5

Frequency range

1884.5

1915.7

-41

0.3

3

DC_14_n2

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 27, 29, 30, 41, 48, 53, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA band 2, 25

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

5

Frequency range

799

805

-35

0.00625

5

DC_14_n5

E-UTRA Band 2, 4, 5, 10, 12, 13, 14, 17, 24, 25, 26, 29, 30, 48, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA band 41, 53

FDL_low

FDL_high

-50

1

2

DC_14_n30

E-UTRA Band 2, 4, 5,12, 13, 14, 17, 24, 25, 26, 27, 29, 30, 41, 48, 53, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

5

Frequency range

799

805

-35

0.00625

5

DC_14_n77

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 26, 27, 29, 30, 41, 53, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

Frequency range

769

775

-35

0.00625

5

Frequency range

799

805

-35

0.00625

5

DC_14_n66

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 25, 26, 27, 29, 30, 41, 53, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA band 48

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

769

775

-35

0.00625

5

Frequency range

799

805

-35

0.00625

5

DC_18_n28

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 10

E-UTRA Band 1, 65

FDL_low

FDL_high

-50

1

2, 9, 11

E-UTRA Band 42, 43

FDL_low

FDL_high

-50

1

2

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 3, 34, 40

FDL_low

FDL_high

-50

1

Frequency range

470

710

-26.2

6

14

Frequency range

758

773

-32

1

5

Frequency range

773

799

-50

1

Frequency range

799

803

-40

1

5

Frequency range

860

890

-40

1

Frequency range

945

960

-50

1

5

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_18_n41

E-UTRA Band 1, 3, 11, 19, 21, 28, 34, 42, 65

NR Band n79

FDL_low

FDL_high

-50

1

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_13_n78

E-UTRA Band 2, 5, 7, 12, 13, 25, 26, 41, 66

FDL_low

FDL_high

-50

1

Frequency range

769

775

-35

0.00625

5

Frequency range

799

805

-35

0.00625

5

DC_18_n3

E-UTRA Band 1, 3, 11, 18, 19, 21, 28, 34, 40, 65

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 42

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_18_n77

E-UTRA Band 1, 3, 11, 21, 28, 34, 40, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_18_n78

E-UTRA Band 1, 3, 11, 21, 28, 34, 40, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_18_n79

E-UTRA Band 1, 3, 11, 21, 28, 34, 40, 42, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_19_n1

E-UTRA Band 1, 11, 21, 28, 40, 42, 65, 74

NR Band n79

FDL_low

FDL_high

-50

1

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA Band 3, 34

FDL_low

FDL_high

-50

1

5

Frequency range

945

960

-50

1

Frequency range

1880

1895

-40

1

5, 16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_19_n77

E-UTRA Band 1, 3, 11, 21, 28, 34, 40, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_19_n78

E-UTRA Band 1, 3, 11, 21, 28, 34, 40, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_19_n79

E-UTRA Band 1, 3, 11, 21, 28, 34, 40, 42, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_20_n1

E-UTRA Band 1, 3, 7, 8, 20, 22, 31, 32, 34, 40, 43, 50, 51, 65, 67, 68, 72, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 38, 42, 69

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

758

788

-50

1

DC_20_n3

E-UTRA Band 1, 7, 8, 31, 32, 33, 34, 40, 43, 50, 51, 65, 67, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 20

E-UTRA Band 3

FDL_low

FDL_high

-50

1

5

E-UTRA Band 22, 38, 42, 52

FDL_low

FDL_high

-50

1

2

Frequency range

758

788

-50

1

DC_20_n7

E-UTRA Band 1, 3, 7, 8, 22, 31, 32, 33, 34, 40, 43, 50, 51, 65, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 42, 52
NR band n78, n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 20

FDL_low

FDL_high

-50

1

5

DC_20_n8

E-UTRA Band 1, 28, 31, 32, 34, 65, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 7, 22, 38, 42, 43

NR Band n78

FDL_low

FDL_high

-50

1

2

DC_20_n38

E-UTRA Band 1, 3, 8, 22, 31, 32, 33, 34, 40, 43, 50, 51, 65, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 42, 52

FDL_low

FDL_high

-50

1

2

E-UTRA Band 20

FDL_low

FDL_high

-50

1

5

DC_20_n41

E-UTRA Band 1, 2, 4, 24, 25, 30, 31, 32, 33, 34, 39, 43, 48, 50, 51, 65, 66, 70, 72, 73, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 8, 12, 13, 14, 17, 42, 44, 45, 52, 67, 68, 71, 85

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 40

FDL_low

FDL_high

-40

1

Frequency range

758

788

-50

1

E-UTRA Band 9, 11, 21

FDL_low

FDL_high

-50

1

19

Frequency range

1884.5

1915.7

-41

0.3

3, 19

DC_20_n28

DC_20_n83

E-UTRA Band 3, 7, 8, 31, 34

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 22, 32, 38, 42, 43, 65, 75, 76

FDL_low

FDL_high

-50

1

2

DC_20_n50

E-UTRA Band 2, 3, 7, 12, 17, 31, 33, 39, 43, 48, 65, 67, 68, 72, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 4, 5, 8, 13, 34, 38, 40, 41, 42, 52, 69

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

758

788

-50

1

DC_20_n51

E-UTRA Band 1, 3, 4, 8, 17, 22, 28, 29, 31, 40, 43, 48, 65, 66, 68, 72

FDL_low

FDL_high

-50

1

E-UTRA Band 20

FDL_low

FDL_high

-50

1

5

Frequency range

758

788

-50

1

E-UTRA Band 2, 7, 25, 32, 33, 34, 35, 36, 37, 38, 39, 41, 42, 46, 69, 70

NR Band n77, n78, n79,

FDL_low

FDL_high

-50

1

2

DC_20_n77

E-UTRA Band 1, 3, 7, 8, 31, 32, 33, 34, 40, 50, 51, 65, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 20

FDL_low

FDL_high

-50

1

5

E-UTRA Band 38, 69

FDL_low

FDL_high

-50

1

2

DC_20_n78,

DC_20_n82_ULSUP-TDM_n78

E-UTRA Band 1, 3, 7, 8, 31, 32, 33, 34, 40, 50, 51, 65, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 20

FDL_low

FDL_high

-50

1

5

E-UTRA Band 38, 69

FDL_low

FDL_high

-50

1

2

DC_20_n80

E-UTRA Band 1, 7, 8, 28, 31, 32, 33, 34, 40, 43, 50, 51, 65, 67, 68, 72, 74, 75, 76.

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 20

FDL_low

FDL_high

-50

1

5

E-UTRA Band 22, 42,

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

DC_20A_91A_ULSUP-TDM,

DC_20A_92A_ULSUP-TDM

E-UTRA Band 1, 3, 7, 8, 22, 31, 32, 33, 34, 40, 43, 50, 51, 65, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 20

FDL_low

FDL_high

-50

1

5

E-UTRA Band 38, 42, 69,

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

758

788

-50

1

DC_21_n1

E-UTRA Band 1, 18, 19, 28, 40, 42, 65

NR Band n78, n79

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 3, 34

FDL_low

FDL_high

-50

1

5

Frequency range

945

960

-50

1

Frequency range

1880

1895

-40

1

5, 16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_21_n28

E-UTRA Band 1, 42, 65,

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 3, 18, 19, 34, 40

NR Band n79

FDL_low

FDL_high

-50

1

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

Frequency range

662

694

-26.2

6

5

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3, 9

Frequency range

2545

2575

-50

1

DC_21_n77

E-UTRA Band 1, 3, 18, 19, 21, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_21_n78

E-UTRA Band 1, 3, 18, 19, 21, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_21_n79

E-UTRA Band 1, 3, 18, 19, 21, 28, 34, 40, 42, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_25_n41

E-UTRA Band 4, 5, 12, 13 , 14, 17, 24, 26, 27, 28, 29, 30, 42, 45, 48, 66, 70, 71

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

5

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_25_n77

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 25, 26, 29, 30, 41, 65, 66, 70, 71

FDL_low

FDL_high

-50

1

DC_25_n78

E-UTRA Band 2, 5, 7, 12, 13, 25, 26, 28, 41, 66

FDL_low

FDL_high

-50

1

DC_26_n25

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 29, 30, 42, 48, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

5

E-UTRA Band 41, 43, 53

FDL_low

FDL_high

-50

1

2

DC_26_n41

E-UTRA Band 1, 2, 3, 4, 5, 11, 12, 13 , 14, 17, 18, 19, 21, 24, 25, 26, 29, 30, 31, 34, 39, 42, 43, 48, 50, 51, 65, 66, 70, 71, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

703

799

-50

1

Frequency range

799

803

-40

1

5

Frequency range

945

960

-50

1

DC_26_n77

E-UTRA Band 1, 3, 5, 11, 18, 19, 21, 26, 34, 39, 40, 65, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

Frequency range

703

799

-50

1

Frequency range

799

803

-40

1

5

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_26_n78

E-UTRA Band 1, 3, 5, 11, 18, 19, 21, 26, 34, 39, 40, 65, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

Frequency range

703

799

-50

1

Frequency range

799

803

-40

1

5

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_26_n79

E-UTRA Band 1, 3, 5, 11, 18, 19, 21, 26, 34, 39, 40, 41, 65, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

Frequency range

703

799

-50

1

Frequency range

799

803

-40

1

5

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_28_n1

E-UTRA Band 5, 7, 8, 18, 19, 20, 26, 27, 31, 38, 40, 41, 72, 73

NR band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 22, 32, 42, 43, 50, 51, 52, 65, 74, 75, 76

NR band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 10

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 11

E-UTRA band 3, 34

FDL_low

FDL_high

-50

1

5

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

Frequency range

662

694

-26.2

6

5

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

1880

1895

-40

1

5,16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

DC_28_n2

E-UTRA Band 5, 26, 27, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 10, 42, 43, 50, 51, 66, 74

FDL_low

FDL_high

-50

1

2

E-UTRA band 2, 25

FDL_low

FDL_high

-50

1

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 1, 65

FDL_low

FDL_high

-50

1

9, 10

Frequency range

470

710

-26.2

6

14

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

2570

2575

1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_28_n3

E-UTRA Band 1, 22, 42, 43, 50, 51, 65, 74, 75, 76,

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 3, 5, 7, 8, 18, 19, 20, 26, 27, 31, 34, 38, 40, 41, 72, 73

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 10

Frequency range

470

710

-26.2

6

14

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3, 9

DC_28_n5

E-UTRA Band 2, 3, 5, 7, 8, 14, 18, 19, 24, 25, 26, 28, 30, 31, 34, 38, 40, 70, 71

FDL_low

FDL_high

-50

E-UTRA Band 4, 22, 32, 41, 42, 43, 45, 48, 50, 51, 52, 65, 66, 73, 74, 75, 76
NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

2, 9, 11

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

2, 9, 10

Frequency range

1884.5

1915.7

-41

0.3

3, 9

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

Frequency range

662

694

-26.2

6

5

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

773

803

-50

1

DC_28_n7

E-UTRA Band 2, 3, 5, 8, 20, 26, 27, 31, 34, 40, 72
NR band n7

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 22, 32, 42, 43, 50, 51, 52, 65, 66, 74, 75, 76

NR band n77, n78

FDL_low

FDL_high

-50

1

2

E-UTRA band 1

FDL_low

FDL_high

-50

1

2, 9, 10

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_28_n8

E-UTRA Band 20, 31, 34, 38, 40, 72

FDL_low

FDL_high

-50

1

E-UTRA band 3, 7, 22, 41, 42, 43, 50, 51, 52, 65, 73, 74, 75, 76

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 10

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

Frequency range

662

694

-26.2

6

5

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3, 9

DC_28_n40

E-UTRA Band 3, 5, 7, 8, 18, 19, 20, 26, 27, 28,31, 34, 38, 41, 72

FDL_low

FDL_high

-50

1

E-UTRA band 1, 11, 21, 22, 32, 42, 43, 50, 51, 52, 65, 73, 74, 75, 76

NR Band, n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_28_n41

DC_28_n83_ULSUP-TDM_n41

E-UTRA Band 4, 14, 18, 19, 20, 26, 27, 39, 42, 43, 48, 50, 51, 52, 65, 66, 71, 73

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

2, 9, 11

E-UTRA Band 2, 3, 5, 8, 24, 25, 30, 31, 34, 70, 72

FDL_low

FDL_high

-50

1

E-UTRA Band 11, 21, 74, 75, 76

FDL_low

FDL_high

-50

1

2, 9, 10

E-UTRA Band 40

FDL_low

FDL_high

-40

1

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

Frequency range

662

694

-26.2

6

5

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3, 9

DC_28_n50

E-UTRA Band 4, 40, 42, 43, 48, 65, 66, 73

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

2, 9, 10

E-UTRA Band 2, 3, 5, 7, 8, 18, 19, 25, 26, 27, 31, 34, 38, 39, 41, 72

FDL_low

FDL_high

-50

1

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

Frequency range

662

694

-26.2

6

5

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

DC_28_n51

E-UTRA Band 2, 3, 5, 7, 8, 25, 26, 31, 34, 38, 40, 41, 72

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 20, 22, 24, 32, 42, 43, 45, 46, 65, 66, 71, 73

NR band n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

2, 9, 10

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

Frequency range

662

694

-26.2

6

5

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

DC_28_n66

E-UTRA Band 2, 5, 7, 25, 26, 27, 38, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 10, 42, 43, 50, 51, 66, 74,

NR band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

Frequency range

662

694

-26.2

6

5

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

DC_28_n77

E-UTRA Band 3, 5, 7, 8, 18, 19, 20, 26, 34, 39, 40, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 65, 74

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 10

Frequency range

758

773

-32

1

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3, 9

DC_28_n78

DC_28_n83_ULSUP-TDM_n78

E-UTRA Band 3, 5, 7, 8, 18, 19, 20, 26, 34, 39, 40, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 65, 74

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 10

Frequency range

758

773

-32

1

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3, 9

DC_28_n79

E-UTRA Band 3, 5, 8, 18, 19, 34, 39, 40, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 42, 65, 74

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

9, 10

Frequency range

758

773

-32

1

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3, 9

DC_30_n2

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 27, 28, 29, 30, 41, 42, 48, 50, 51, 53, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 25

FDL_low

FDL_high

-50

1

5

E-UTRA Band 2

FDL_low

FDL_high

-50

1

5

E-UTRA Band 43,

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_30_n5

E-UTRA Band 2, 4, 5, 7, 12, 13, 14, 17, 24, 25, 26, 29, 30, 38, 48, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 41, 53

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_30_n66

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 26, 27, 29, 30, 38, 41, 66, 70, 71

FDL_low

FDL_high

-50

1

E-UTRA Band 48,

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_30_n77

E-UTRA Band 2, 4, 5, 7, 12, 13, 14, 17, 24, 25, 26, 27, 29, 30, 41, 53, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

DC_38_n1

E-UTRA Band 1, 3, 5, 8, 20, 22, 27, 28, 31, 32, 34, 40, 42, 43, 50, 51, 65, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

DC_38_n3

E-UTRA Band 1, 5, 8, 20, 27, 28, 31, 32, 33, 34, 40, 43, 50, 51, 65, 67, 68, 72, 74, 75, 76

FDL_low

FDL_high

-50

1

E-UTRA Band 22, 42

FDL_low

FDL_high

-50

1

2

DC_38_n8

E-UTRA Band 1, 2, 4, 12, 13, 14, 17 20, 27, 28, 29, 30, 31, 32, 33, 34, 39, 40, 45, 50, 51, 65, 66, 67, 68, 72, 73, 74, 75, 76, 85, 87, 88

FDL_low

FDL_high

-50

1

E-UTRA band 3, 22, 42, 43, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

12

Frequency range

860

890

-40

1

5, 12

Frequency range

1884.5

1915.7

-41

0.3

3, 12

Frequency range

2620

2645

-15.5

5

5, 7, 22

Frequency range

2645

2690

-40

1

5, 22

DC_38_n28

E-UTRA Band 1, 4, 22, 32, 42, 43, 50, 51, 52, 65, 66, 74, 75, 76,

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

Frequency range

662

694

-26.2

6

5

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

E-UTRA Band 1, 4, 22, 32, 42, 43, 50, 51, 52, 65, 66, 74, 75, 76,

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

DC_38_n78

N/A

DC_38_n79

E-UTRA Band 1, 3, 5, 8, 28, 34, 40, 42, 65, 74

FDL_low

FDL_high

-50

1

Frequency range

2620

2645

-15.5

5

5, 7, 22

Frequency range

2645

2690

-40

1

5, 22

DC_39_n40

E-UTRA Band 1, 8, 22, 26, 28, 34, 41, 42, 44, 45, 50, 51, 52, 73, 74

FDL_low

FDL_high

-50

1

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1805

1855

-40

1

18

Frequency range

1855

1880

-15.5

5

5, 7, 18

DC_39_n41

E-UTRA Band 1, 8, 26, 28, 34, 42, 44, 45, 50, 51, 74

FDL_low

FDL_high

-50

1

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 40

FDL_low

FDL_high

-40

1

Frequency range

1805

1855

-40

1

5

Frequency range

1855

1880

-15.5

5

5, 7, 19

DC_39_n78

E-UTRA Band 1, 8, 28, 34, 40, 41, 44, 45

FDL_low

FDL_high

-50

1

Frequency range

1805

1855

-40

1

18

Frequency range

1855

1880

-15.5

5

18

DC_39_n79

E-UTRA Band 1, 8, 28, 34, 40, 41, 44, 45

FDL_low

FDL_high

-50

1

Frequency range

1805

1855

-40

1

18

Frequency range

1855

1880

-15.5

5

18

DC_40_n1

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 20, 21, 22, 26, 27, 28, 31, 32, 38, 41, 42, 43, 44, 45, 50, 51, 52, 65, 67, 68, 69, 72, 73, 74, 75, 76

NR Band n78

FDL_low

FDL_high

-50

1

E-UTRA Band 34

FDL_low

FDL_high

-50

1

5

NR Band n77, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_40_n41

Bands 1, 3, 5, 8, 11, 18, 19, 21, 26, 27, 28, 34, 39, 42, 44, 45, 50, 51, 65, 73, 74, NR Band n77, n78

FDL_low

FDL_high

-50

1

NR Band n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_40_n77

N/A

DC_40_n78

E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 20, 21, 26, 27, 28, 31, 32, 33, 34, 38, 39, 41, 44, 45, 50, 51, 65, 67, 68, 69, 72, 73, 74, 75, 76

FDL_low

FDL_high

-50

1

NR Band n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_40_n79

Bands 1, 3, 5, 8, 11, 18, 19, 21, 26, 28, 34, 39, 41, 42, 65, 74

NR band n78

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_41_n1

E-UTRA Band 1, 5, 8, 11, 18, 19, 21, 26, 27, 28, 40, 42, 44, 45, 50, 51, 52, 65, 73, 74

NR Band n78

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 34

FDL_low

FDL_high

-50

1

5

NR Band n77, n79

FDL_low

FDL_high

-50

1

2

Frequency range

1880

1895

-40

1

5, 16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

DC_41_n3

E-UTRA Band 1, 5, 8, 26, 27, 28, 34, 39, 44, 45, 50, 51, 65, 73, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 3

FDL_low

FDL_high

-50

1

5

E-UTRA Band 42, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 40

FDL_low

FDL_high

-40

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_41_n28

E-UTRA Band 4, 14, 18, 19, 20, 26, 27, 39, 42, 43, 48, 50, 51, 52, 65, 66, 71, 73

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

E-UTRA Band 2, 3, 5, 8, 24, 25, 30, 31, 34, 70, 72

FDL_low

FDL_high

-50

1

E-UTRA Band 11, 21, 74, 75, 76

FDL_low

FDL_high

-50

1

9, 10

E-UTRA Band 40

FDL_low

FDL_high

-40

1

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

Frequency range

662

694

-26.2

6

5

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3, 9

DC_41_n77

E-UTRA Band 1, 3, 5, 8, 11, 18, 19, 21, 26, 28, 33, 34, 39, 44, 45, 73, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 40

FDL_low

FDL_high

-40

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_41_n78

E-UTRA Band 1, 3, 5, 8, 11, 18, 19, 21, 26, 28, 34, 39, 44, 45, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 40

FDL_low

FDL_high

-40

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_41_n79

E-UTRA Band 1, 3, 5, 8, 11, 18, 19, 21, 26, 28, 34, 42, 44, 45, 65, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 40

FDL_low

FDL_high

-40

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_42_n1

E-UTRA Band 1, 5, 7, 8, 11, 18, 19, 20, 21, 26, 27, 28, 31, 32, 38, 40, 41, 44, 45, 50, 51, 65, 67, 68, 69, 72, 73, 74, 75, 76,

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 34

FDL_low

FDL_high

-50

1

5

Frequency range

1880

1895

-40

1

5, 16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

DC_42_n3

E-UTRA Band 1, 5, 7, 8, 11, 18, 19, 20, 21, 26, 27, 28, 31, 32, 33, 34, 38, 40, 41, 44, 45, 50, 51, 65, 67, 68, 69, 72, 73, 74, 75, 76

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 3

FDL_low

FDL_high

-50

1

5

Frequency range

1884.5

1915.7

-41

0.3

3

DC_42_n51

E-UTRA Band 3, 8, 20, 25, 30, 31, 34, 39, 41, 73

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 2, 4, 5, 6, 7, 12, 13, 14, 17, 23, 24, 26, 27, 28, 29, 32, 38, 40, 44, 46, 65, 66, 67, 68, 70, 71

FDL_low

FDL_high

-50

1

2

DC_42_n77

N/A

DC_42_n78

N/A

DC_42_n79

N/A

DC_48_n5

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 26, 29, 30, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_48_n12

E-UTRA Band 2, 5, 13, 14, 17, 24, 25, 26, 30, 41, 71, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 50, 51, 66, 70

FDL_low

FDL_high

-50

1

2

E-UTRA Band 12, 85

FDL_low

FDL_high

-50

1

5

DC_48_n25

E-UTRA Band 4, 5, 12, 13 , 14, 17, 24, 26, 29, 30, 41, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

Frequency range

1880

1895

-40

1

5, 16

Frequency range

1895

1915

-15.5

5

5, 7, 16

Frequency range

1915

1920

+1.6

5

5, 7, 16

DC_48_n66

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 26, 29, 30, 41, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

DC_48_n71

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 30, 50, 51, 53, 66, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25, 41, 70

FDL_low

FDL_high

-50

1

2

E-UTRA Band 29

FDL_low

FDL_high

-38

1

5

E-UTRA Band 71

FDL_low

FDL_high

-50

1

5

DC_48_n77

N/A

DC_66_n2

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 27, 28, 29, 30, 41, 50, 51, 53, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 25

FDL_low

FDL_high

-50

1

5

E-UTRA Band 2

FDL_low

FDL_high

-50

1

5

E-UTRA Band 22, 42, 43,

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_66_n5

E-UTRA Band 1, 2, 3, 4, 5, 6, 7, 8, 12, 13, 14, 17, 24, 25, 26, 28, 29, 30, 34, 38, 40, 43, 45, 50, 51, 65, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 41, 42, 48, 52,

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_66_n7

E-UTRA Band 2, 4, 5, 7, 12, 13, 14, 17, 26, 27, 28, 29, 30, 43, 50, 51, 66, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 42

FDL_low

FDL_high

-50

1

2

Frequency range

2570

2575

+1.6

5

5, 6, 7

Frequency range

2575

2595

-15.5

5

5, 6, 7

Frequency range

2595

2620

-40

1

5, 6

DC_66_n12

E-UTRA Band 2, 5, 13, 14, 17, 24, 25, 26, 27, 30, 41, 50, 53, 70, 71, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 51, 66, 48,

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 12, 85

FDL_low

FDL_high

-50

1

5

DC_66_n25

E-UTRA Band 4, 5, 7, 12, 13, 14, 17, 24, 26, 27, 28, 29, 30, 38, 41, 50, 51, 53, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 42, 48,

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 2

FDL_low

FDL_high

-50

1

5

E-UTRA Band 25

FDL_low

FDL_high

-50

1

5

E-UTRA Band 43

FDL_low

FDL_high

-50

1

2

DC_66_n28

E-UTRA Band 2, 5, 7, 25, 26, 27, 38, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 10, 42, 43, 50, 51, 66, 74,

NR band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

Frequency range

662

694

-26.2

6

5

Frequency range

758

773

-32

1

5

Frequency range

773

803

-50

1

DC_66_n30

E-UTRA Band 2, 4, 5, 7, 12, 13, 14, 17, 24, 25, 26, 27, 29, 30, 38, 41, 53, 66, 70, 71, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 48,

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_66_n41

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 26, 27, 28, 29, 30, 43, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 42, 48,

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_66_n38

EUTRA 2, 4, 5, 12, 13,14,17, 25, 27, 28, 29, 30, 43, 50, 51, 66, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 42

FDL_low

FDL_high

-50

1

2

Frequency range

2620

2645

-15.5

5

5, 7, 22

Frequency range

2645

2690

-40

1

5, 22

DC_66_n48

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 26, 29, 30, 41, 50, 51, 66, 70, 71, 74, 85

FDL_low

FDL_high

-50

1

DC_66_n71

E-UTRA Band 4, 5, 13, 14, 17, 24, 26, 27, 29, 30, 43, 50, 51, 66, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 7, 22, 25, 41, 42, 48, 70,

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 71

FDL_low

FDL_high

-50

1

5

DC_66_n77

E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 26, 29, 30, 41, 65, 66, 70, 71

FDL_low

FDL_high

-50

1

DC_66_n78,

DC_66_n86_ULSUP-TDM_n78

E-UTRA Band 1, 3, 5, 7, 8, 20, 26, 28, 34, 39, 40, 41, 65

FDL_low

FDL_high

-50

1

DC_71_n2

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 30, 48, 66

FDL_low

FDL_high

-50

1

E-UTRA Band 25, 41, 70,

NR Band n2, n77

FDL_low

FDL_high

-50

1

2

E-UTRA band 71

FDL_low

FDL_high

-50

1

5

E-UTRA Band 29

FDL_low

FDL_high

-38

1

5

DC_71_n5

E-UTRA Band 4, 12, 13, 14, 17, 24, 26, 30, 48, 66, 85

NR Band n5

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25, 41, 70,

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 29

FDL_low

FDL_high

-38

1

5

E-UTRA Band 71

FDL_low

FDL_high

-50

1

5

DC_71_n38

E-UTRA Band 4, 5, 12, 13, 14, 17, 30, 66, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 2

FDL_low

FDL_high

-50

1

2

E-UTRA band 29

FDL_low

FDL_high

-50

1

5

DC_71_n41

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 30, 48, 66, 85

FDL_low

FDL_high

-50

1

E-UTRA band 2, 25, 70

FDL_low

FDL_high

-50

1

2

E-UTRA band 71

FDL_low

FDL_high

-50

1

5

E-UTRA Band 29

FDL_low

FDL_high

-38

1

5

DC_71_n48

E-UTRA Band 4, 5, 12, 13, 14, 17, 24, 26, 29, 30, 50, 51, 66, 71, 74, 85

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25, 41, 70

FDL_low

FDL_high

-50

1

2

DC_71_n66

E-UTRA Band 4, 5, 13, 14, 17, 24, 26, 27, 29, 30, 43, 50, 51, 66, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 7, 22, 25, 41, 42, 48, 70,

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 71

FDL_low

FDL_high

-50

1

5

DC_71_n78

E-UTRA Band 5, 26

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

NOTE 1: FDL_low and FDL_high refer to each frequency band specified in Table 5.5-1 in TS 36.101 [4] or in Table 5.2-1 in TS 38.101-1 [2].

NOTE 2: As exceptions, measurements with a level up to the applicable requirements defined in Table 6.6.3.1-2 in TS 36.101 [4] and Table 6.5.3.1-2 in TS 38.101-1 [2] are permitted for each assigned carrier used in the measurement due to 2nd, 3rd, 4th or 5th harmonic spurious emissions. Due to spreading of the harmonic emission the exception is also allowed for the first 1 MHz frequency range immediately outside the harmonic emission on both sides of the harmonic emission. This results in an overall exception interval centred at the harmonic emission of (2 MHz + N x LCRB x 180 kHz), where N is 2, 3, 4, 5 for the 2nd, 3rd, 4th or 5th harmonic respectively. The exception is allowed if the measurement bandwidth (MBW) totally or partially overlaps the overall exception interval.

NOTE 3: Applicable when co-existence with PHS system operating in 1884.5 – 1915.7 MHz

NOTE 4: Void

NOTE 5: These requirements also apply for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1, Table 6.6.3.1A-1 in TS 36.101 [4] or in Table 6.5.3.1-1 in TS 38.101-1 [2] from the edge of the channel bandwidth.

NOTE 6: This requirement is applicable for any channel bandwidths within the range 2500 – 2570 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 2560.5 – 2562.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 2552 – 2560 MHz the requirement is applicable only for an uplink transmission bandwidth less than or equal to 54 RB.

NOTE 7: For these adjacent bands, the emission limit could imply risk of harmful interference to UE(s) operating in the protected operating band.

NOTE 8: This requirement is applicable for any channel bandwidths within the range 1920 – 1980 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 1927.5 – 1929.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 1930 – 1938 MHz the requirement is applicable only for an uplink

NOTE 9: Applicable when the assigned E-UTRA or NR carrier is confined within 718 MHz and 748 MHz and when the channel bandwidth used is 5 or 10 MHz.

NOTE 10: As exceptions, measurements with a level up to the applicable requirement of -38 dBm/MHz is permitted for each assigned E-UTRA carrier used in the measurement due to 2nd harmonic spurious emissions. An exception is allowed if there is at least one individual RB within the transmission bandwidth (see Figure 5.6-1) for which the 2nd harmonic totally or partially overlaps the measurement bandwidth (MBW).

NOTE 11: As exceptions, measurements with a level up to the applicable requirement of -36 dBm/MHz is permitted for each assigned E-UTRA carrier used in the measurement due to 3rd harmonic spurious emissions. An exception is allowed if there is at least one individual RB within the transmission bandwidth (see Figure 5.6-1) for which the 3rd harmonic totally or partially overlaps the measurement bandwidth (MBW).

NOTE 12: This requirement is applicable only for the following cases: A: for carriers of 5 MHz channel bandwidth when carrier centre frequency (Fc) is within the range 902.5 MHz ≤ Fc < 907.5 MHz with an uplink transmission bandwidth less than or equal to 20 RB; B: for carriers of 5 MHz channel bandwidth when carrier centre frequency (Fc) is within the range 907.5 MHz ≤ Fc ≤ 912.5 MHz without any restriction on uplink transmission bandwidth; C: for carriers of 10 MHz channel bandwidth when carrier centre frequency (Fc) is Fc = 910 MHz with an uplink transmission bandwidth less than or equal to 32 RB with RBstart > 3.

NOTE 13: Void

NOTE 14: This requirement is applicable for 5 and 10 MHz E-UTRA or NR channel bandwidth allocated within 718-728MHz. For carriers of 10 MHz bandwidth, this requirement applies for an uplink transmission bandwidth less than or equal to 30 RB with RBstart > 1 and RBstart < 48.

NOTE 15: Void

NOTE 16: This requirement is applicable for any channel bandwidths within the range 1920 – 1980 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 1927.5 – 1929.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 1930 – 1938 MHz the requirement is applicable only for an uplink transmission bandwidth less than or equal to 54 RB.

NOTE 17: This requirement is applicable in the case of a 10 MHz E-UTRA or NR carrier confined within 703 MHz and 733 MHz, otherwise the requirement of -25 dBm with a measurement bandwidth of 8 MHz applies.

NOTE 18: This requirement is only applicable for E-UTRA carriers with bandwidth confined within 1885 – 1920 MHz (requirement for carriers with at least 1RB confined within 1880 – 1885 MHz is not specified). This requirement applies for an uplink transmission bandwidth less than or equal to 54 RB for E-UTRA carriers of 15 MHz bandwidth when carrier center frequency is within the range 1892.5 – 1894.5 MHz and for E-UTRA carriers of 20 MHz bandwidth when carrier center frequency is within the range 1895 – 1903 MHz.

NOTE 19: Void

NOTE 20: Void.

NOTE 21: Void

NOTE 22: This requirement is applicable for power class 3 UE for any channel bandwidths within the range 2570 – 2615 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 2605.5 – 2607.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 2597 – 2605 MHz the requirement is applicable only for an uplink transmission bandwidth less than or equal to 54 RB.

NOTE: To simplify the above Table, E-UTRA band numbers are listed for bands which are specified only for E-UTRA operation or both E-UTRA and NR operation. NR band numbers are listed for bands which are specified only for NR operation.

The normative reference for this requirement is TS 38.101-3 [4] clause 6.5B.3.3.2.

Exception requirements for both NR and E-UTRA are defined for this test and therefore LTE anchor agnostic approach is not applied. E-UTRA test point analysis is included and E-UTRA measurements are performed.

6.5B.3.3.2.4 Test description

6.5B.3.3.2.4.1 Initial conditions

Same initial conditions as described in clause 6.5B.3.1.2.4.1 with the following exceptions:

– Instead of Table 6.5B.3.1.2.4.1-1 ‑‑> use Table 6.5B.3.3.2.4.1-1.

Table 6.5B.3.3.2.4.1-1: Test Configuration Table

Initial Conditions

Test Environment

as specified in TS 38.508-1 [6] clause 4.1

Normal

Test Frequencies

as specified in TS 38.508-1 [6] clause 4.3.1

For test frequencies refer to "Range" columns.

Test EN-DC channel bandwidth as specified in TS 36.508 [11] clause 4.3.1 and TS 38.508-1 [6] clause 4.3.1

Refer to "NR NRB"and "E-UTRA NRB " columns

Test SCS for the NR cell as specified in TS 38.521-1 [8] Table 5.3.5-1

Lowest SCS per Channel Bandwidth

Test Parameters for DC Configurations

ID

DC Configuration / NRB_agg

DL Allocation

UL Allocation (Note 1,2)

DC Configuration

E-UTRA

Ch BW/NRB

NR

Ch BW/NRB

CC MOD

E-UTRA/NR

E-UTRA & NR RB allocation

CC MOD

E-UTRA/NR

E-UTRA & NR allocations
(LCRB @ RBstart)

E-UTRA

NR

Band

Range

Band

Range

Default Test Settings for a DC_XA_nYA Configuration

1

X

Low

nY

Low

Highest Ch BW /Highest NRB

Highest Ch BW /Highest NRB

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

X

High

nY

High

Highest Ch BW /Highest NRB

Highest Ch BW /Highest NRB

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@RBmax

1@RBmax

Test Setting for DC_1A_n3A Configuration

1

1

Low

n3

Low

10/50

30/160

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

1

High

n3

Mid

10/50

30/160

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@0

Test Setting for DC_1A_n5A Configuration

1

1

Low

n5

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

1

High

n5

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@105

Test Setting for DC_1A_n7A Configuration

1

1

High

n7

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

2

1

High

n7

Mid

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@14

Test Setting for DC_1A_n8A Configuration

1

1

Low

n8

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_1A_n28A Configuration

1

1

Low

n28

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

1

Low

n28

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

3

1

High

n28

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@105

Test Setting for DC_1A_n77A Configuration

1

1

High

n77

High

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@0

2

1

Low

n77

Mid

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

3

1

Low

n77

Low

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

4

1

Low

n77

NOTE 18

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

5

1

Low

n77

NOTE 18

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

6

1

Low

n77

NOTE 18

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

7

1

Low

n77

NOTE 18

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

8

1

Low

n77

NOTE 18

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_1A_n78A Configuration

1

1

High

n78

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@272

2

1

Low

n78

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

3

1

Low

n78

Note 8

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_1A_n79A Configuration

1

1

Low

n79

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@172

2

1

High

n79

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

3

1

High

n79

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

4

1

Low

n79

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@201

5

1

High

n79

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@272

Test Setting for DC_2A_n41A Configuration

1

2

Low

n41

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

2

2

Low

n41

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@30

3

2

Low

n41

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@62

4

2

Low

n41

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@209

5

2

High

n41

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@272

6

2

Low

n41

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_2A_n66A Configuration

1

2

Low

n66

Low

20/100

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

2

High

n66

High

20/100

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@215

3

2

High

n66

Low

20/100

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

4

2

High

n66

Low

20/100

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

5

2

High

n66

High

20/100

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@215

Test Setting for DC_2A_n71A Configuration

1

2

Low

n71

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_2A_n77A Configuration

1

2

Low

n77

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

2

2

High

n77

Note 27

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@200

3

2

HIgh

n77

Note 27

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@272

Test Setting for DC_2A_n78A Configuration

1

2

Low

n78

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

2

2

Low

n78

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

3

2

High

n78

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@272

4

2

Low

n78

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

Test Settings for DC_3A_n1A Configuration

1

3

Low

n1

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

3

Low

n1

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@105

Test Setting for DC_3A_n5A Configuration

1

3

Low

n5

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@77

2

3

High

n5

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@105

3

3

Low

n5

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

4

3

Low

n5

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

5

3

High

n5

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

Test Setting for DC_3A_n7A Configuration

1

3

Low

n7

High

20/100

10/52

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@47

1@51

2

3

Mid

n7

High

20/100

10/52

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@51

3

3

Low

n7

Low

20/100

10/52

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@51

4

3

Mid

n7

Low

20/100

10/52

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

5

3

Low

n7

High

20/100

10/52

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@51

Test Setting for DC_3A_n8A Configuration

1

3

Low

n8

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

3

High

n8

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@105

3

3

Low

n8

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@105

Test Settings for DC_3A_n28A Configuration

1

3

Low

n28

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

3

Low

n28

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@105

3

3

High

n28

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@105

Test Settings for DC_3A_n41A Configuration

1

3

Low

n41

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

3

High

n41

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@272

3

3

Mid

n41

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

4

3

Note 4

n41

High

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@272

Test Setting for DC_3A_n77A Configuration

1

3

Low

n77

NOTE 19

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

3

Low

n77

NOTE 19

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

3

3

Low

n77

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

4

3

Low

n77

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@75

5

3

Low

n77

NOTE 19

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

6

3

Low

n77

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

7

3

High

n77

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

Test Setting for DC_3A_n78A Configuration

1

3

High

n78

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@272

2

3

High

n78

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@272

3

3

Low

n78

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

Test Settings for DC_3A_n79A Configuration

1

3

High

n79

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@105

2

3

High

n79

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@272

3

3

Low

n79

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

4

3

High

n79

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@134

5

3

Low

n79

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@66

Test Settings for DC_5A_n2A Configuration

1

5

Low

n2

Low

10/50

20/106

QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

5

High

n2

High

10/50

20/106

QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@105

Test Settings for DC_5A_n66A Configuration

1

5

High

n66

Mid

10/50

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@0

2

5

High

n66

High

10/50

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@215

3

5

Low

n66

Low

10/50

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@215

4

5

High

n66

Low

10/50

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@0

Test Setting for DC_5A_n77A Configuration

1

5

High

n77

Mid

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@0

2

5

Low

n77

Mid

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

3

5

Low

n77

Note 28

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@272

4

5

Low

n77

Note 28

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

5

5

Low

n77

Note 28

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

6

5

Low

n77

Low

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

7

5

High

n77

High

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@272

Test Setting for DC_5A_n78A Configuration

1

5

Low

n78

High

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

2

5

Low

n78

Mid

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

3

5

Low

n78

Mid

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

4

5

High

n78

High

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@29

5

5

Low

n78

Low

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

Test Setting for DC_7A_n1A Configuration

1

7

Low

n1

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

7

Low

n1

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@105

3

7

Mid

n1

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@22

1@105

Test Setting for DC_7A_n3A Configuration

1

7

High

n3

Low

20/100

30/160

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@77

2

7

Low

n3

Low

20/100

30/160

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@59

3

7

High

n3

High

20/100

30/160

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@86

4

7

High

n3

Low

10/50

5/25

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@0

5

7

High

n3

Low

20/100

30/160

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

6

7

Low

n3

Mid

20/100

30/160

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@66

Test Setting for DC_7A_n5A Configuration

1

7

High

n5

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@105

2

7

Low

n5

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_7A_n8A Configuration

1

7

High

n8

Mid

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

2

7

High

n8

Mid

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@105

3

7

Low

n8

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_7A_n28A Configuration

1

7

High

n28

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@105

Test Setting for DC_7A_n66A Configuration

1

7

Low

n66

High

20/100

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@215

2

7

Low

n66

High

20/100

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

3

7

Mid

n66

High

20/100

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@50

1@215

4

7

Low

n66

High

20/100

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@215

5

7

Mid

n66

Low

20/100

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

6

7

High

n66

Low

20/100

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

Test Setting for DC_7A_n78A Configuration

1

7

Low

n78

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

7

Mid

n78

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

3

7

Low

n78

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@196

4

7

Low

n78

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@272

5

7

High

n78

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@77

1@0

6

7

Mid

n78

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@272

7

7

High

n78

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

8

7

High

n78

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

9

7

High

n78

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

10

7

Low

n78

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@165

Test Settings for DC_8A_n1A Configuration

1

8

Low

n1

Low

10/50

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Settings for DC_8A_n3A Configuration

1

8

High

n3

Low

10/50

30/160

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@0

2

8

Low

n3

Low

10/50

30/160

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@159

3

8

High

n3

High

10/50

30/160

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@159

Test Settings for DC_8A_n20A Configuration

1

8

High

n20

Low

10/50

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@12

2

8

High

n20

High

10/50

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@105

3

8

Low

n20

Low

10/50

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Settings for DC_8A_n28A Configuration

1

8

High

n28

High

10/50

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@105

2

8

Low

n28

Low

10/50

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@105

Test Settings for DC_8A_n41A Configuration

1

8

Low

n41

Mid

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

8

Low

n41

High

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

3

8

Low

n41

Low

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

4

8

High

n41

High

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@272

Test Settings for DC_8A_n77A Configuration

1

8

Low

n77

Note 9

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

8

High

n77

Low

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@37

3

8

High

n77

Mid

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@97

4

8

Low

n77

Mid

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@211

5

8

Low

n77

Note 9

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

6

8

High

n77

High

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@272

7

8

High

n77

Mid

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@0

8

8

Low

n77

Note 9

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

9

8

High

n77

Low

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@85

Test Settings for DC_8A_n78A Configuration

1

8

High

n78

Mid

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@272

2

8

High

n78

Low

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

3

8

Low

n78

High

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@272

4

8

High

n78

High

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

5

8

High

n78

High

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@0

6

8

Mid

n78

Low

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@25

1@0

Test Settings for DC_11A_n77A Configuration

1

11

Low

n77

Note 10

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

11

Low

n77

Low

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

3

11

Low

n77

Mid

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@63

4

11

Low

n77

Mid

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@104

5

11

Low

n77

Note 10

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

6

11

Low

n77

Note 10

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

7

11

Low

n77

Note 10

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

8

11

Low

n77

Low

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@75

9

11

Low

n77

Note 10

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

10

11

Low

n77

Note 10

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Settings for DC_11A_n78A Configuration

1

11

Low

n78

Mid

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@184

2

11

Low

n78

Low

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

3

11

Low

n78

High

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@63

4

11

Low

n78

High

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@104

5

11

Low

n78

Note 11

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

6

11

Low

n78

Note 11

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

7

11

Low

n78

Low

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@75

Test Settings for DC_11A_n79A Configuration

1

11

Low

n79

High

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

2

11

Low

n79

Mid

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@132

3

11

High

n79

High

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@30

4

11

Low

n79

Mid

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

Test Setting for DC_12A_n66A Configuration

1

12

Low

n66

Low

10/50

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

12

High

n66

High

10/50

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@215

3

12

Low

n66

High

10/50

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@215

Test Setting for DC_12A_n78A Configuration

1

12

Low

n78

Low

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

12

High

n78

Low

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@272

3

12

Low

n78

Mid

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@136

Test Setting for DC_13A_n2A Configuration

1

13

Low

n2

Low

10/50

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_13A_n77A Configuration

1

13

Mid

n77

Note 29

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@272

2

13

Mid

n77

Mid

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@0

3

13

Mid

n77

Note 29

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@210

4

13

Low

n77

Note 29

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

5

13

Low

n77

Note 29

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

6

13

High

n77

HIGH

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@272

7

13

Low

n77

LOW

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_14A_n2A Configuration

1

14

Low

n2

Low

10/50

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_14A_n66A Configuration

1

14

Low

n66

Low

10/50

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

14

High

n66

High

10/50

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@215

Test Setting for DC_19A_n1A Configuration

1

19

Low

n1

Low

15/75

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_19A_n77A Configuration

1

19

Low

n77

Mid

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

2

19

Low

n77

Note 26

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

3

19

High

n77

Mid

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@74

1@0

4

19

Low

n77

Note 26

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

5

19

Low

n77

Note 26

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

6

19

Low

n77

Low

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

7

19

Low

n77

Note 26

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_19A_n78A Configuration

1

19

High

n78

High

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@74

1@272

2

19

Low

n78

Mid

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

3

19

High

n78

High

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@74

1@0

4

19

Low

n78

Mid

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@165

5

19

Low

n78

Low

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

6

19

Low

n78

Note 17

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_19A_n79A Configuration

1

19

Low

n79

Low

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_20A_n1A Configuration

1

20

Low

n1

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

20

High

n1

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@105

Test Setting for DC_20A_n3A Configuration

1

20

Low

n3

Low

20/100

30/160

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

20

High

n3

High

20/100

30/160

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@159

3

20

Low

n3

High

20/100

30/160

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@159

Test Setting for DC_20A_n7A Configuration

1

20

High

n7

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

2

20

High

n7

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@105

3

20

Low

n7

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

4

20

High

n7

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_20A_n8A Configuration

1

20

Low

n8

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

20

High

n8

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@105

3

20

Low

n8

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@105

Test Setting for DC_20A_n28A Configuration

1

20

Low

n28

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@105

Test Setting for DC_20A_n78A Configuration

1

20

Low

n78

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

2

20

Low

n78

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

3

20

Low

n78

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@205

4

20

High

n78

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@104

5

20

Low

n78

Note 24

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_21A_n77A Configuration

1

21

Low

n77

Note 21

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

21

Low

n77

Low

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

3

21

Low

n77

Mid

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@174

4

21

Low

n77

Mid

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@215

5

21

High

n77

Mid

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@74

1@0

6

21

Low

n77

Note 21

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

7

21

Low

n77

Note 21

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

8

21

Low

n77

Low

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@130

9

21

Low

n77

Note 21

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

10

21

High

n77

High

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@74

1@0

Test Setting for DC_21A_n1A Configuration

1

21

Low

n1

Low

15/75

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

21

High

n1

High

15/75

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@74

1@105

3

21

Low

n1

Low

15/75

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@105

Test Setting for DC_21A_n78A Configuration

1

21

Low

n78

Mid

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

2

21

Low

n78

Low

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

3

21

High

n78

High

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@74

1@272

4

21

Low

n78

High

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@215

5

21

High

n78

High

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@74

1@0

6

21

Low

n78

Note 20

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

7

21

Low

n78

Low

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@130

Test Setting for DC_21A_n79A Configuration

1

21

Low

n79

Mid

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

2

21

Low

n79

Low

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

3

21

Low

n79

High

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@38

4

21

Low

n79

Note 22

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_25A_n41A Configuration

1

25

Low

n41

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

2

25

Low

n41

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@30

3

25

Low

n41

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@62

4

25

Low

n41

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@209

5

25

High

n41

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@272

6

25

Low

n41

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_26A_n41A Configuration

1

26

High

n41

High

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@74

1@272

2

26

Low

n41

Low

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@12

3

26

Low

n41

Low

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@41

4

26

High

n41

Low

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@74

1@0

5

26

Low

n41

Low

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@232

Test Setting for DC_26A_n77A Configuration

1

26

Low

n77

Mid

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

2

26

Low

n77

NOTE 25

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

3

26

High

n77

Mid

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@74

1@34

4

26

Low

n77

NOTE 25

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

5

26

Low

n77

NOTE 25

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

6

26

Low

n77

Low

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@201

7

26

Low

n77

High

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

8

26

Low

n77

NOTE 25

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_26A_n78A Configuration

1

26

Low

n78

High

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

2

26

Low

n78

Mid

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

3

26

High

n78

High

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@74

1@34

4

26

Low

n78

Mid

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@78

5

26

Low

n78

Low

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@201

6

26

Low

n78

Note 13

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_26A_n79A Configuration

N/A (Note 14)

Test Setting for DC_28A_n3A Configuration

1

28

Low

n3

Low

20/100

30/160

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

28

High

n3

High

20/100

30/160

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@159

3

28

High

n3

Low

20/100

30/160

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

Test Setting for DC_28A_n5A Configuration

1

28

High

n5

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@105

2

28

Low

n5

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

3

28

High

n5

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

Test Setting for DC_28A_n7A Configuration

1

28

High

n7

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@105

Test Setting for DC_28A_n77A Configuration

1

28

High

n77

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

2

28

Low

n77

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@158

3

28

High

n77

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@130

4

28

Low

n77

Note 23

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

5

28

Low

n77

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

6

28

Low

n77

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

7

28

Low

n77

Note 23

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_28A_n78A Configuration

1

28

Low

n78

Low

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

28

High

n78

High

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@272

3

28

Mid

n78

Mid

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@272

4

28

High

n78

Low

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@190

5

28

High

n78

Mid

10/50

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_28A_n79A Configuration

1

28

High

n79

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@272

Test Setting for DC_30A_n5A Configuration

1

30

High

n5

High

10/50

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@49

1@105

Test Settings for DC_39A_n41A Configuration

1

39

High

n41

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@272

Test Settings for DC_39A_n79A Configuration

1

39

Low

n79

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@146

2

39

Low

n79

Note 5

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Settings for DC_40A_n1A Configuration

1

40

Low

n1

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

40

High

n1

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@105

3

40

High

n1

Mid

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@56

4

40

High

n1

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@77

5

40

High

n1

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@39

Test Settings for DC_40A_n41A Configuration

1

40

Low

n41

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

40

High

n41

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@272

3

40

Mid

n41

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@50

1@272

4

40

Low

n41

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

Test Settings for DC_40A_n78A Configuration

1

40

Low

n78

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@79

2

40

High

n78

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@110

3

40

Low

n78

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

4

40

Low

n78

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@234

5

40

High

n78

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@29

6

40

Low

n78

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@50

7

40

Low

n78

High

15/75

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

8

40

High

n78

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

9

40

Low

n78

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@110

10

40

Low

n78

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@155

11

40

High

n78

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@183

12

40

Low

n78

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

Test Settings for DC_40A_n79A Configuration

1

40

Low

n79

Low

20/100

50/270

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@269

2

40

High

n79

Low

20/100

50/270

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

3

40

High

n79

High

20/100

50/270

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@269

Test Settings for DC_41A_n77A Configuration

1

41

Mid

n77

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

41

Low

n77

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@185

3

41

Low

n77

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@57

4

41

Low

n77

Note 15

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

5

41

Low

n77

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

6

41

High

n77

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@201

7

41

Mid

n77

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@46

8

41

Low

n77

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@214

9

41

Low

n77

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@29

10

41

High

n77

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@272

11

41

Mid

n77

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

12

41

Low

n77

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

13

41

Low

n77

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

14

41

Mid

n77

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

15

41

High

n77

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@161

16

41

High

n77

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@122

17

41

Mid

n77

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@27

Test Settings for DC_41A_n78A Configuration

1

41

High

n78

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

2

41

Low

n78

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@185

3

41

High

n78

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

4

41

Low

n78

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

5

41

Low

n78

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@214

6

41

Low

n78

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@69

7

41

Low

n78

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

8

41

High

n78

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@161

9

41

Mid

n78

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

10

41

Low

n78

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@98

Test Settings for DC_41A_n79A Configuration

1

41

Low

n79

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

41

High

n79

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@272

3

41

High

n79

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@188

4

41

High

n79

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@93

5

41

Mid

n79

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

6

41

High

n79

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@151

7

41

High

n79

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@272

8

41

Low

n79

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Setting for DC_42A_n77A Configuration

N/A (Note 14)

Test Settings for DC_48A_n5A Configuration

1

48

High

n5

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@105

2

48

High

n5

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@105

3

48

Low

n5

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Settings for DC_48A_n66A Configuration

1

48

High

n66

Low

20/100

40/216

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

Test Settings for DC_66A_n2A Configuration

1

66

Low

n2

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

66

High

n2

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@105

3

66

Low

n2

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@105

4

66

Low

n2

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@105

5

66

Low

n2

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@46

Test Settings for DC_66A_n5A Configuration

1

66

Low

n5

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

2

66

High

n5

High

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@105

3

66

Low

n5

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

4

66

High

n5

Low

20/100

20/106

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

Test Settings for DC_66A_n41A Configuration

1

66

Low

n41

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

2

66

Low

n41

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@0

3

66

High

n41

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@59

4

66

Low

n41

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@248

5

66

High

n41

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@89

6

66

Low

n41

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@218

7

66

High

n41

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

8

66

Low

n41

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@186

9

66

Low

n41

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@203

10

66

High

n41

Low

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@0

Test Settings for DC_66A_n71A Configuration

N/A (Note 14)

Test Setting for DC_66A_n77A Configuration

1

66

High

n77

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@272

2

66

Low

n77

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@110

3

66

Low

n77

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@166

4

66

Low

n77

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@220

5

66

High

n77

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@100

6

66

High

n77

Note 30

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

7

66

High

n77

HIgh

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@50

8

66

Low

n77

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@196

9

66

Low

n77

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@47

Test Settings for DC_66A_n78A Configuration

1

66

Low

n78

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@143

2

66

High

n78

High

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@99

1@272

3

66

Low

n78

Mid

20/100

100/273

QPSK/CP-OFDM QPSK

NA

QPSK / CP-OFDM QPSK

1@0

1@272

Note 1: Use DC Configuration – specific test points if present in the table, otherwise use test points from matching Group Test Settings, if present in the table. Otherwise use the Default Test Settings test points.

Note 2: X, nY correspond to the different bands in the DC Configuration. E.g. for DC_1A_n3A, X=1, nY=n3.

Note 3: Void.

Note 4: Test Point ID 4 for DC_3A_n41A have the centre carrier frequency of 1773 MHz in Band 3 (EARFCN=19830).

Note 5: Test Point ID 4 for DC_39A_n79A has the centre carrier frequency of 4649.96 MHz in Band 79 (NR ARFCN=709998).

Note 6: Void.

Note 7: Void.

Note 8: Test Point ID 3 for DC_1A_n78A has the centre carrier frequency of 3473.43 MHz in Band 78 (NR ARFCN=631562).

Note 9: Test Point ID 1 for DC_8A_n77A has the centre carrier frequency of 3950.13 MHz in Band n77 (NR ARFCN=663342). Test Point ID 5 has the centre carrier frequency of 3524.55 MHz in Band n77 (NR ARFCN=634970). Test Point ID 8 has the centre carrier frequency of 3584.55 MHz in Band n77 (NR ARFCN=638970).

Note 10: Test Point ID 1 for DC_11A_n77A has the centre carrier frequency of 3617.43 MHz in Band n77 (NR ARFCN=641162). Test Point ID 5 has the centre carrier frequency of 3686.43 MHz in Band n77 (NR ARFCN=645762). Test Point ID 6 has the centre carrier frequency of 3494.94 MHz in Band n77 (NR ARFCN=632996). Test Point ID 7 has the centre carrier frequency of 3858.42 MHz in Band n77 (NR ARFCN=657228). Test Point ID 9 has the centre carrier frequency of 4037.43 MHz in Band n77 (NR ARFCN=669162). Test Point ID 10 has the centre carrier frequency of 4097.43 MHz in Band n77 (NR ARFCN=673162).

Note 11: Test Point ID 5 for DC_11A_n78A has the centre carrier frequency of 3686.43 MHz in Band n78 (NR ARFCN=645762). Test Point ID 6 has the centre carrier frequency of 3494.94 MHz in Band n78 (NR ARFCN=632996).

Note 12: Void.

Note 13: Test Point ID 6 for DC_26A_n78A has the centre carrier frequency of 3483.78 MHz in Band n78 (NR ARFCN=632252).

Note 14: Test case not applicable for the EN-DC configuration as no IM products occurs in the protected bands. For EN-DC only capable devices, the test requirements as in clause 6.5.3.2.5 in TS 38.521-1 [8] is needed.

Note 15: Test Point ID 4 for DC_41A_n77A has the centre carrier frequency of 3488.55 MHz in Band n77 (NR ARFCN=632570).

Note 16: Void.

Note 17: Test Point ID 6 for DC_19A_n78A has the centre carrier frequency of 3499.8 MHz in Band n78 (NR ARFCN=633320).

Note 18: Test Point ID 4 for DC_1A_n77A has the centre carrier frequency of 3472.95 MHz in Band n77 (NR ARFCN=631530). Test Point ID 5 has the centre carrier frequency of 3987.03 MHz in Band n77 (NR ARFCN=665802). Test Point ID 6 has the centre carrier frequency of 3857.04 MHz in Band n77 (NR ARFCN=657136). Test Point ID 7 has the centre carrier frequency of 3874.53 MHz in Band n77 (NR ARFCN=658302). Test Point ID 8 has the centre carrier frequency of 3887.04 MHz in Band n77 (NR ARFCN=659136).

Note 19: Test Point ID 1 for DC_3A_n77A has the centre carrier frequency of 3900.03 MHz in Band n77 (NR ARFCN=660002). Test Point ID 2 has the centre carrier frequency of 3602.55 MHz in Band n77 (NR ARFCN=640170). Test Point ID 5 has the centre carrier frequency of 3660.15 MHz in Band n77 (NR ARFCN=644010).

Note 20: Test Point ID 6 for DC_21A_n78A has the centre carrier frequency of 3515.19 MHz in Band n78 (NR ARFCN=634346).

Note 21: Test Point ID 1 for DC_21A_n77A has the centre carrier frequency of 3637.68 MHz in Band n77 (NR ARFCN=642512). Test Point ID 6 has the centre carrier frequency of 3515.19 MHz in Band n77 (NR ARFCN=634346). Test Point ID 7 has the centre carrier frequency of 3898.92 MHz in Band n77 (NR ARFCN=659928). Test Point ID 9 has the centre carrier frequency of 4057.68 MHz in Band n77 (NR ARFCN=670512).

Note 22: Test Point ID 4 for DC_21A_n79A has the centre carrier frequency of 4846.53 MHz in Band n79 (NR ARFCN=723102).

Note 23: Test Point ID 4 for DC_28A_n77A has the centre carrier frequency of 3474,63 MHz in Band n77 (NR ARFCN=631642). Test Point ID 7 for have the centre carrier frequency of 3597,12 MHz in Band n77 (NR ARFCN=639808).

Note 24: Test Point ID 5 for DC_20A_n78A has the centre carrier frequency of 3477.03 MHz in Band n78 (NR ARFCN=631802).

Note 25: Test Point ID 2 for DC_26A_n77A has the centre carrier frequency of 3521.13 MHz in Band n77 (NR ARFCN=634742). Test Point ID 4 has the centre carrier frequency of 3578.73 MHz in Band n77 (NR ARFCN=638582). Test Point ID 5 has the centre carrier frequency of 4028.64 MHz in Band n77 (NR ARFCN=668576). Test Point ID 8 has the centre carrier frequency of 3483.78 MHz in Band n77 (NR ARFCN=632252).

Note 26: Test Point ID 2 for DC_19A_n77A has the centre carrier frequency of 3553.14 MHz in Band n77 (NR ARFCN=636876). Test Point ID 4 has the centre carrier frequency of 4060.62 MHz in Band n77 (NR ARFCN=670708). Test Point ID 5 has the centre carrier frequency of 3610.74 MHz in Band n77 (NR ARFCN=640716). Test Point ID 7 has the centre carrier frequency of 3499.8 MHz in Band n77 (NR ARFCN=633320).

Note 27: Test Point ID 2 for DC_2A_n77A have the centre carrier frequency of 3900 MHz in Band n77 (NR ARFCN=660000). Test Point ID 3 for DC_2A_n77A have the centre carrier frequency of 4000 MHz in Band n77 (NR ARFCN=666667).

Note 28: Test Point ID 3 for DC_5A_n77A have the centre carrier frequency of 4000 MHz in Band n77 (NR ARFCN=666667). Test Point ID 4 for DC_5A_n77A have the centre carrier frequency of 3600 MHz in Band n77 (NR ARFCN=640000). Test Point ID 5 for DC_5A_n77A have the centre carrier frequency of 3658.14 MHz in Band n77 (NR ARFCN=643876).

Note 29: Test Point ID 1 for DC_13A_n77A have the centre carrier frequency of 3500 MHz in Band n77 (NR ARFCN=633333). Test Point ID 3 for DC_13A_n77A have the centre carrier frequency of 3880 MHz in Band n77 (NR ARFCN=658668). Test Point ID 4 for DC_13A_n77A have the centre carrier frequency of 3611.64 MHz in Band n77 (NR ARFCN=640776). Test Point ID 5 for DC_13A_n77A have the centre carrier frequency of 3504.24 MHz in Band n77 (NR ARFCN=633616).

Note 30: Test Point ID 6 for DC_66A_n77A have the centre carrier frequency of 3900 MHz in Band n77 (NR ARFCN=660000).

Additional step 9 when both bands are TDD:

8. For both E-UTRA and NR UL uplink carriers active when both bands are TDD, ensure E-UTRA UL transmission overlaps with NR UL transmission in time by giving SCG a delay of 3 E-UTRA subframes, or by giving MCG a delay of 2 subframes.

6.5B.3.3.2.4.2 Test Procedure

Same test procedure as described in clause 6.5B.3.1.2.4.2 with the following exceptions:

Instead of Table 6.5B.3.1.2.3-1 ‑‑> use Table 6.5B.3.3.2.5-1 and 6.5B.3.3.2.5-2.

In addition to test configurations above, EN-DC only capable UEs and UEs not supporting NR/5GC mode in the tested band needs to be tested according to LTE anchor agnostic approach below.

Same test description as in clause 6.5.3.2.4 in TS 38.521-1 [8] for the NR carrier with the following exceptions:

The initial test configurations for E-UTRA consist of test frequency based on E-UTRA operating band and test channel bandwidth as specified in Table 4.6-1.

For Initial conditions as in clause 6.5.3.2.4.1 in TS 38.521-1 [8], the following steps will be added to configure E-UTRA component:

2.1. The parameter settings for the cell are set up according to TS 36.508 [11] clause 4.4.3.

3.1. The E-UTRA downlink signal level, uplink signal level are set according to Table 4.6-1 and propagation conditions are set according to Annex B.0 of TS 36.521-1 [10].

Step 6 of Initial conditions as in clause 6.5.3.2.4.1 in TS 38.521-1 [8] is replaced by:

6. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508 [6] clause 4.5.

7. On the E-UTRA carrier, disable periodic and aperiodic CQI reports, disable SRS, set TimeAlignmentTimerDedicated IE to infinity and disable downlink and uplink scheduling, all as per Table 4.6-1 under clause 4.6.

6.5B.3.3.2.4.3 Message Contents

Message contents are according to TS 36.508 [11] clause 4.6 and TS 38.508-1 [6] clause 4.6.1 with the following exceptions.

Table 6.5B.3.3.2.4.3-1: SystemInfomationBlockType1: tdd-Config if E-UTRA on TDD band

Derivation Path: TS 36.508 [11], Table 4.6.3-23

Information Element

Value/remark

Comment

Condition

TDD-Config-DEFAULT ::= SEQUENCE {

Operating on TDD band

subframeAssignment

Sa2

specialSubframePatterns

Ssp7

}

Table 6.5B3.3.2.4.3-1a: Void

Table 6.5B.3.3.2.4.3-2: RRCConnectionReconfiguration: nr-Config-r15

Derivation Path: TS 36.508 [11], Table 4.6.1-8

Information Element

Value/remark

Comment

Condition

p-MaxEUTRA-r15

23

Power Class 2 UE AND simultaneous E-UTRA and NR transmission

20

Power Class 3 UE AND simultaneous E-UTRA and NR transmission

Table 6.5B.3.3.2.4.3-3: PhysicalCellGroupConfig

Derivation Path: TS 38.508-1 [6] Table 4.6.3-106

Information Element

Value/remark

Comment

Condition

p-NR-FR1

23

Power Class 2 UE AND simultaneous E-UTRA and NR transmission

20

Power Class 3 UE AND simultaneous E-UTRA and NR transmission

6.5B.3.3.2.5 Test Requirement

The test requirements are in Table 6.5B.3.3.2.5-1 and Table 6.5B.3.3.2.5-2 for Release 15 and Release 16, respectively. For EN-DC only capable devices, in addition to Table 6.5B.3.3.2.5-1 and Table 6.5B.3.3.2.5-2, the test requirements as in clause 6.5.3.2.5 in TS 38.521-1 [8] are also needed.

For inter-band EN_DC with the uplink assigned to one LTE band and one NR band, the test requirements in Table 6.5B.3.3.2.5-1 and Table 6.5B.3.3.2.5-2 can be verified by measuring spurious emissions at the specific frequencies where second and third order intermodulation products generated by the two transmitted carriers can occur.

Table 6.5B.3.3.2.5-1: Requirements for inter-band within FR1 for Rel-15

EN-DC Configuration

Spurious emission

Protected band

Frequency range (MHz)

Maximum Level (dBm)

MBW (MHz)

NOTE

DC_1_n28

E-UTRA Band 7, 31, 41, 72, 73

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 42, 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

DC_1_n77

E-UTRA Band 1, 3, 11, 21, 34, 65, 74

FDL_low

FDL_high

-50

1

 

Frequency range

1880

1895

-40

1

5, 8

Frequency range

1895

1915

-15.5

5

5, 7, 8

Frequency range

1915

1920

1.6

5

5, 7, 8

DC_1_n78

E-UTRA Band 3, 11, 21, 74

FDL_low

FDL_high

-50

1

Frequency range

1880

1895

-40

1

5, 8

DC_1_n79

E-UTRA Band 5, 7, 8, 18, 19, 26, 28, 41

FDL_low

FDL_high

-50

1

DC_2_n5

E-UTRA Band 42, 48

FDL_low

FDL_high

-50

1

E-UTRA Band 41, 43

FDL_low

FDL_high

-50

1

2

DC_2_n66

E-UTRA Band 4, 10, 24, 50, 66, 70, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

5

E-UTRA Band 42, 48

FDL_low

FDL_high

-50

1

2

DC_2_n71

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

DC_2_n78

E-UTRA Band 24, 50, 51, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

2

DC_3_n7

E-UTRA Band 5, 8, 20, 26, 27, 28, 44, 67

FDL_low

FDL_high

-50

1

E-UTRA Band 42

FDL_low

FDL_high

-50

1

2

DC_3_n8

E-UTRA Band 20, 28, 38, 69

FDL_low

FDL_high

-50

1

E-UTRA Band 7, 22, 41, 42, 43
NR band n77, n78, n79

FDL_low

FDL_high

-50

1

2

DC_3_n28

NR band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 7, 41

FDL_low

FDL_high

-50

1

DC_3_n77

E-UTRA Band 1, 3, 28, 34, 39, 40, 65, 74

FDL_low

FDL_high

-50

1

 

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n78

E-UTRA Band 3, 34, 39

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n79

E-UTRA Band 5, 8, 11, 18, 19, 21, 41, 74

FDL_low

FDL_high

-50

1

DC_5_n66

E-UTRA Band 5, 6, 7, 8, 38

FDL_low

FDL_high

-50

1

E-UTRA Band 26

859

869

-27

1

E-UTRA Band 41, 42, 52

FDL_low

FDL_high

-50

1

2

DC_5_n78

E-UTRA Band 1, 2, 3, 4, 7, 25, 34, 38, 65, 66, 70

FDL_low

FDL_high

-50

1

 

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2, 7

DC_7_n28

E-UTRA Band 3

FDL_low

FDL_high

-50

1

NR band n78

FDL_low

FDL_high

-50

1

2

DC_7_n78

E-UTRA Band 3, 5, 8, 11, 18, 19, 20, 21, 26, 27, 28, 32, 50, 51, 67, 68, 74, 75, 76

FDL_low

FDL_high

-50

1

DC_8_n77

E-UTRA Band 1, 32, 33, 34, 38, 39, 40,50, 65, 69, 74, 75

FDL_low

FDL_high

-50

1

E-UTRA band 3, 7, 41

FDL_low

FDL_high

-50

1

2

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

12

Frequency range

1884.5

1915.7

-41

0.3

3, 12

DC_8_n78

E-UTRA band 34, 39, 40, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 7, 41

FDL_low

FDL_high

-50

1

2

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

12

Frequency range

1884.5

1915.7

-41

0.3

3, 12

DC_11_n77

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_11_n78

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_11_n79

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 42, 65

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_12_n66

E-UTRA Band 41

FDL_low

FDL_high

-50

1

DC_19_n77

E-UTRA Band 1, 3, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_19_n78

E-UTRA Band 1, 3, 34, 65

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_19_n79

E-UTRA Band 42

FDL_low

FDL_high

-50

1

DC_20_n28

E-UTRA Band 8

FDL_low

FDL_high

-50

1

DC_20_n78

E-UTRA Band 1, 3, 7, 33, 34, 65

FDL_low

FDL_high

-50

1

 

E-UTRA Band 38, 69

FDL_low

FDL_high

-50

1

2

DC_21_n77

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

 

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_21_n78

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_21_n79

E-UTRA Band 3, 21, 34, 42

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_25_n41

E-UTRA Band 12, 13, 14, 17, 28, 29, 42, 71

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

5

DC_26_n41

E-UTRA Band 3, 5, 18, 19, 26, 42

FDL_low

FDL_high

-50

1

Frequency range

799

803

-40

1

5

Frequency range

945

960

-50

1

DC_26_n77

E-UTRA Band 1, 3, 34, 39, 40, 65

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_26_n78

E-UTRA Band 1, 3, 34, 39, 65

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

2

Frequency range

2595

2645

-50

1

DC_28_n77

E-UTRA Band 3, 7, 34, 39, 40, 41

FDL_low

FDL_high

-50

1

 

E-UTRA Band 1, 65

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

Frequency range

1884.5

1915.7

-41

0.3

3, 9

DC_28_n78

DC_28_n83_ULSUP-TDM_n78

E-UTRA Band 3, 7, 34, 39, 40, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 65

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

Frequency range

1884.5

1915.7

-41

0.3

3

DC_28_n79

E-UTRA Band 42

FDL_low

FDL_high

-50

1

2

DC_30_n5

E-UTRA Band 71

FDL_low

FDL_high

-50

1

DC_39_n41

E-UTRA Band 42, 44

FDL_low

FDL_high

-50

1

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

DC_39_n79

E-UTRA Band 8, 41, 44

FDL_low

FDL_high

-50

1

DC_40_n41

Bands 1, 34, 39, 65

FDL_low

FDL_high

-50

1

NR Band n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3, 19

DC_41_n77

E-UTRA Band 3, 5, 8, 11, 18, 19, 21, 26, 28, 33, 34, 39, 44, 45, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_41_n78

E-UTRA Band 3, 5, 8, 11, 18, 19, 21, 26, 28, 34, 39, 44, 45, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_41_n79

E-UTRA Band 1, 3, 5, 8, 18, 19, 26, 28, 34, 40, 44, 65

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_66_n5

E-UTRA Band 5, 6, 7, 8, 26, 38

FDL_low

FDL_high

-50

1

E-UTRA Band 41, 42, 52

FDL_low

FDL_high

-50

1

2

DC_66_n78

E-UTRA Band 3, 34, 39

FDL_low

FDL_high

-50

1

NOTE 1: FDL_low and FDL_high refer to each frequency band specified in Table 5.5-1 of TS 36.101 [5] or in Table 5.2-1 in TS 38.101-1 [2].

NOTE 2: As exceptions, measurements with a level up to the applicable requirements defined in Table 6.6.3.1-2 in TS 36.101 [5] and Table 6.5.3.1-2 in TS 38.101-1 [2] are permitted for each assigned carrier used in the measurement due to 2nd, 3rd, 4th or 5th harmonic spurious emissions. Due to spreading of the harmonic emission the exception is also allowed for the first 1 MHz frequency range immediately outside the harmonic emission on both sides of the harmonic emission. This results in an overall exception interval centred at the harmonic emission of (2MHz + N x LCRB x 180kHz), where N is 2, 3, 4, 5 for the 2nd, 3rd, 4th or 5th harmonic respectively. The exception is allowed if the measurement bandwidth (MBW) totally or partially overlaps the overall exception interval.

NOTE 3: Applicable when co-existence with PHS system operating in 1884.5 -1915.7MHz

NOTE 4: Void.

NOTE 5: These requirements also apply for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1, Table 6.6.3.1A-1in TS 36.101 [5] or in Table 6.5.3.1-1 in TS 38.101-1 [2] from the edge of the channel bandwidth.

NOTE 6: This requirement is applicable for any channel bandwidths within the range 2500 – 2570 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 2560.5 – 2562.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 2552 – 2560 MHz the requirement is applicable only for an uplink transmission bandwidth less than or equal to 54 RB.

NOTE 7: For these adjacent bands, the emission limit could imply risk of harmful interference to UE(s) operating in the protected operating band.

NOTE 8: This requirement is applicable for any channel bandwidths within the range 1920 – 1980 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 1927.5 – 1929.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 1930 – 1938 MHz the requirement is applicable only for an uplink.

NOTE 9: Applicable when the assigned E-UTRA or NR carrier is confined within 718 MHz and 748 MHz and when the channel bandwidth used is 5 or 10 MHz.

NOTE 10: As exceptions, measurements with a level up to the applicable requirement of -38 dBm/MHz is permitted for each assigned E-UTRA carrier used in the measurement due to 2nd harmonic spurious emissions. An exception is allowed if there is at least one individual RB within the transmission bandwidth (see Figure 5.6-1) for which the 2nd harmonic totally or partially overlaps the measurement bandwidth (MBW).

NOTE 11: As exceptions, measurements with a level up to the applicable requirement of -36 dBm/MHz is permitted for each assigned E-UTRA carrier used in the measurement due to 3rd harmonic spurious emissions. An exception is allowed if there is at least one individual RB within the transmission bandwidth (see Figure 5.6-1) for which the 3rd harmonic totally or partially overlaps the measurement bandwidth (MBW).

NOTE 12: This requirement is applicable only for the following cases:
A: for carriers of 5 MHz channel bandwidth when carrier centre frequency (Fc) is within the range 902.5 MHz ≤ Fc < 907.5 MHz with an uplink transmission bandwidth less than or equal to 20 RB:
B: for carriers of 5 MHz channel bandwidth when carrier centre frequency (Fc) is within the range 907.5 MHz ≤ Fc ≤ 912.5 MHz without any restriction on uplink transmission bandwidth;
C: for carriers of 10 MHz channel bandwidth when carrier centre frequency (Fc) is Fc = 910 MHz with an uplink transmission bandwidth less than or equal to 32 RB with RBstart > 3.

NOTE 13: Void.

NOTE 14: This requirement is applicable for 5 and 10 MHz E-UTRA or NR channel bandwidth allocated within 718-728MHz. For carriers of 10 MHz bandwidth, this requirement applies for an uplink transmission bandwidth less than or equal to 30 RB with RBstart > 1 and RBstart < 48.

NOTE 15: Void.

NOTE 16: This requirement is applicable for any channel bandwidths within the range 1920 – 1980 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 1927.5 – 1929.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 1930 – 1938 MHz the requirement is applicable only for an uplink transmission bandwidth less than or equal to 54 RB.

NOTE 17: This requirement is applicable in the case of a 10 MHz E-UTRA carrier confined within 703 MHz and 733 MHz, otherwise the requirement of -25 dBm with a measurement bandwidth of 8 MHz applies.

NOTE 18: This requirement is only applicable for E-UTRA carriers with bandwidth confined within 1885 – 1920 MHz (requirement for carriers with at least 1RB confined within 1880 – 1885 MHz is not specified). This requirement applies for an uplink transmission bandwidth less than or equal to 54 RB for E-UTRA carriers of 15 MHz bandwidth when carrier centre frequency is within the range 1892.5 – 1894.5 MHz and for E-UTRA carriers of 20 MHz bandwidth when carrier centre frequency is within the range 1895 – 1903 MHz.

NOTE 19: Void.

Table 6.5B.3.3.2.5-2: Requirements for inter-band within FR1 for Rel-16

EN-DC Configuration

Spurious emission

Protected band

Frequency range (MHz)

Maximum Level (dBm)

MBW (MHz)

NOTE

DC_1_n3

E-UTRA Band 1, 11, 21, 32, 43, 50, 65, 74, 75

FDL_low

FDL_high

-50

1

NR Band 77, 78

FDL_low

FDL_high

-50

1

2

DC_1_n5

E-UTRA Band 22, 42, 43

FDL_low

FDL_high

-50

1

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

DC_1_n7

E-UTRA Band 32, 50, 51, 75, 76

FDL_low

FDL_high

-50

1

NR Band n79

FDL_low

FDL_high

-50

1

DC_1_n8

E-UTRA Band 43
NR band n77, n78, n79

FDL_low

FDL_high

-50

1

2

DC_1_n28

E-UTRA Band 7, 31, 41, 72, 73

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 42, 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

DC_1_n77

E-UTRA Band 1, 3, 11, 21, 34, 65, 74

FDL_low

FDL_high

-50

1

 

Frequency range

1880

1895

-40

1

5, 8

Frequency range

1895

1915

-15.5

5

5, 7, 8

Frequency range

1915

1920

1.6

5

5, 7, 8

DC_1_n78

E-UTRA Band 3, 11, 21, 74

FDL_low

FDL_high

-50

1

Frequency range

1880

1895

-40

1

5, 8

DC_1_n79

E-UTRA Band 5, 7, 8, 18, 19, 26, 28, 41

FDL_low

FDL_high

-50

1

DC_2_n5

E-UTRA Band 42, 48

NR band n77

FDL_low

FDL_high

-50

1

E-UTRA Band 41, 43

FDL_low

FDL_high

-50

1

2

DC_2_n41

E-UTRA Band 12, 13, 14, 17, 28, 29, 42, 71

FDL_low

FDL_high

-50

1

E-UTRA Bands 2

FDL_low

FDL_high

-50

1

5

DC_2_n66

E-UTRA Band 4, 10, 24, 50, 66, 70, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

5

E-UTRA Band 42, 48

FDL_low

FDL_high

-50

1

2

DC_2_n71

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

DC_2_n78

E-UTRA Band 24, 50, 51, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

2

DC_3_n1

E-UTRA Band 1, 11, 21, 32, 50, 65, 74, 75

FDL_low

FDL_high

-50

1

DC_3_n5

E-UTRA Band 5, 7, 8, 18,19, 26, 38

FDL_low

FDL_high

-50

1

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 42, 52

FDL_low

FDL_high

-50

1

2

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

DC_3_n7

E-UTRA Band 5, 8, 20, 26, 27, 28, 44, 67

FDL_low

FDL_high

-50

1

E-UTRA Band 42

FDL_low

FDL_high

-50

1

2

DC_3_n28

NR band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 7, 41

FDL_low

FDL_high

-50

1

DC_3_n41

E-UTRA Band 5, 8, 20, 26, 27, 28, 44

FDL_low

FDL_high

-50

1

E-UTRA Band 18, 19

FDL_low

FDL_high

-50

1

14, 20

E-UTRA Band 42,

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

DC_3_n77

E-UTRA Band 1, 3, 28, 34, 39, 40, 65, 74

FDL_low

FDL_high

-50

1

 

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n78

E-UTRA Band 3, 34, 39

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n79

E-UTRA Band 5, 8, 11, 18, 19, 21, 41, 74

FDL_low

FDL_high

-50

1

DC_5_n2

E-UTRA Band 42

FDL_low

FDL_high

-50

1

E-UTRA Band 41, 43

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_5_n66

E-UTRA Band 5, 6, 7, 8, 38

FDL_low

FDL_high

-50

1

E-UTRA Band 26

859

869

-27

1

E-UTRA Band 41, 42, 52

FDL_low

FDL_high

-50

1

2

NR Band n77

DC_5_n78

E-UTRA Band 1, 2, 3, 4, 7, 25, 34, 38, 65, 66, 70

FDL_low

FDL_high

-50

1

 

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2, 7

DC_7_n1

E-UTRA Band 32, 50, 51, 75, 76 or NR Band n79

FDL_low

FDL_high

-50

1

DC_7_n3

E-UTRA Band 5, 8, 20, 26, 27, 28, 67, 68

FDL_low

FDL_high

-50

1

E-UTRA band 42, 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

DC_7_n5

E-UTRA Band 5, 26, 28, 42

FDL_low

FDL_high

-50

1

E-UTRA Band 52

FDL_low

FDL_high

-50

1

2

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

DC_7_n8

E-UTRA Band 20, 28, 67, 68

FDL_low

FDL_high

-50

1

E-UTRA Band 42, 52
NR band n77, n78

FDL_low

FDL_high

-50

1

2

DC_7_n28

E-UTRA Band 3

FDL_low

FDL_high

-50

1

NR band n78

FDL_low

FDL_high

-50

1

2

DC_7_n66

E-UTRA Band 5, 12, 13, 14, 17, 26, 27, 28, 29, 85

FDL_low

FDL_high

-50

1

E-UTRA band 42

FDL_low

FDL_high

-50

1

2

DC_7_n78

E-UTRA Band 3, 5, 8, 11, 18, 19, 20, 21, 26, 27, 28, 32, 50, 51, 67, 68, 74, 75, 76

FDL_low

FDL_high

-50

1

DC_8_n1

E-UTRA Band 43 or NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

DC_8_n3

E-UTRA Band 20, 28, 38, 44

FDL_low

FDL_high

-50

1

E-UTRA Band 7, 22, 41, 42, 43 or NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

860

890

-40

1

5, 12

DC_8_n20

E-UTRA Band 67, 68

749

783

-50

1

 

E-UTRA Band 7, 38, 69

2570

2690

-50

1

2

E-UTRA Band 8, 20

FDL_low

FDL_high

-50

1

5

Frequency range

758

788

-50

1

 

DC_8_n28

E-UTRA Band 38, 40

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

Frequency range

491

616

-42

8

5, 17

Frequency range

491

616

-26.2

6

14

DC_8_n41

E-UTRA Band 28

FDL_low

FDL_high

-50

1

 

E-UTRA band 3, 42, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

Frequency range

860

890

-40

1

5, 12

DC_8_n77

E-UTRA Band 1, 32, 33, 34, 38, 39, 40,50, 65, 69, 74, 75

FDL_low

FDL_high

-50

1

E-UTRA band 3, 7, 41

FDL_low

FDL_high

-50

1

2

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

12

Frequency range

1884.5

1915.7

-41

0.3

3, 12

DC_8_n78

E-UTRA band 34, 39, 40, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 7, 41

FDL_low

FDL_high

-50

1

2

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

12

Frequency range

1884.5

1915.7

-41

0.3

3, 12

DC_11_n77

E-UTRA Band 1, 3, 18, 19, 28, 34, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_11_n78

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_11_n79

E-UTRA Band 1, 3, 34, 42, 65

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_12_n78

E-UTRA Band 2, 7, 25, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 66

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_13_n2

E-UTRA Band 41

FDL_low

FDL_high

-50

1

DC_13_n66

E-UTRA Band 41, 53

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_14_n2

E-UTRA Band 41

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

DC_14_n66

E-UTRA Band 41

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

DC_19_n77

E-UTRA Band 1, 3, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_19_n78

E-UTRA Band 1, 3, 34, 65

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_19_n79

E-UTRA Band 42

FDL_low

FDL_high

-50

1

DC_20_n1

E-UTRA Band 22, 42, 43

FDL_low

FDL_high

-50

1

NR Band 77, 78

FDL_low

FDL_high

-50

1

2

DC_20_n3

E-UTRA Band 7, 8

FDL_low

FDL_high

-50

1

E-UTRA Band 38, 42, 52

FDL_low

FDL_high

-50

1

2

DC_20_n7

 

 

 

E-UTRA Band 68

776

783

-50

1

 

E-UTRA Band 42, 52

3332

3432

-50

1

2

NR band n77, n78

3332

3432

-50

1

2

E-UTRA Band 20

FDL_low

FDL_high

-50

1

5

DC_20_n8

E-UTRA Band 28

FDL_low

FDL_high

-50

1

 

E-UTRA Band 7, 38

FDL_low

FDL_high

-50

1

2

DC_20_n28

E-UTRA Band 8

FDL_low

FDL_high

-50

1

DC_20_n78

E-UTRA Band 1, 3, 7, 33, 34, 65

FDL_low

FDL_high

-50

1

 

E-UTRA Band 38, 69

FDL_low

FDL_high

-50

1

2

DC_21_n77

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_21_n78

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_21_n79

E-UTRA Band 3, 21, 34, 42

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_25_n41

E-UTRA Band 12, 13, 14, 17, 28, 29, 42, 71

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_26_n41

E-UTRA Band 3, 5, 18, 19, 26, 42

FDL_low

FDL_high

-50

1

Frequency range

799

803

-40

1

5

Frequency range

945

960

-50

1

DC_26_n77

E-UTRA Band 1, 3, 34, 39, 40, 65

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_26_n78

E-UTRA Band 1, 3, 34, 39, 65

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

2

Frequency range

2595

2645

-50

1

DC_28_n3

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 7, 41

FDL_low

FDL_high

-50

1

DC_28_n5

E-UTRA Band 8, 40, 71

FDL_low

FDL_high

-50

1

E-UTRA Band 24

1527

1559

-50

1

E-UTRA Band 30

2351

2360

-50

1

Frequency range

557

672

-42

8

5, 17

Frequency range

557

672

-26.2

6

14

Frequency range

662

672

-26.2

6

5

DC_28_n7

E-UTRA Band 3

FDL_low

FDL_high

-50

1

E-UTRA Band 52

FDL_low

FDL_high

-50

1

2

NR band n77, n78

FDL_low

FDL_high

-50

1

2

DC_28_n77

E-UTRA Band 3, 7, 34, 39, 40, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 65

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

Frequency range

1884.5

1915.7

-41

0.3

3, 9

DC_28_n78

DC_28_n83_ULSUP-TDM_n78

E-UTRA Band 3, 7, 34, 39, 40, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 65

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

Frequency range

1884.5

1915.7

-41

0.3

3

DC_28_n79

E-UTRA Band 42

FDL_low

FDL_high

-50

1

2

DC_30_n5

E-UTRA Band 71

FDL_low

FDL_high

-50

1

NR band n77

FDL_low

FDL_high

-50

1

2

DC_39_n41

E-UTRA Band 42, 44

FDL_low

FDL_high

-50

1

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

DC_39_n79

E-UTRA Band 8, 28, 41, 44

FDL_low

FDL_high

-50

1

DC_40_n1

E-UTRA Band 7, 31, 32, 41, 45, 50, 72, 73, 74, 75

FDL_low

FDL_high

-50

1

 

DC_40_n41

Bands 1, 34, 39, 65

FDL_low

FDL_high

-50

1

NR Band n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3, 19

DC_40_n78

E-UTRA Band 5, 8, 11, 18, 19, 20, 21, 26, 27, 28, 32, 44, 45, 50, 51, 74, 75, 76

FDL_low

FDL_high

-50

1

NR Band n79

FDL_low

FDL_high

-50

1

2

DC_40_n79

E-UTRA Band 1, 34, 41, 65

FDL_low

FDL_high

-50

1

DC_41_n77

E-UTRA Band 3, 5, 8, 11, 18, 19, 21, 26, 28, 33, 34, 39, 44, 45, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_41_n78

E-UTRA Band 3, 5, 8, 11, 18, 19, 21, 26, 28, 34, 39, 44, 45, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_41_n79

E-UTRA Band 1, 3, 5, 8, 9, 18, 19, 26, 28, 34, 40, 44, 65

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_48_n5

E-UTRA Band 25, 70

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_48_n66

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

DC_66_n2

E-UTRA Band 4, 10, 22, 24, 50, 66, 70, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

5

E-UTRA Band 42, 43

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_66_n5

E-UTRA Band 5, 6, 7, 8, 26, 38

FDL_low

FDL_high

-50

1

E-UTRA Band 41, 42, 52

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_66_n41

E-UTRA Band 5, 12, 13, 14, 17, 26, 27, 28, 29, 43, 85

FDL_low

FDL_high

-50

1

 

E-UTRA Band 42, 48,
NR band n77

FDL_low

FDL_high

-50

1

2

DC_66_n78

E-UTRA Band 3, 34, 39

FDL_low

FDL_high

-50

1

NOTE 1: FDL_low and FDL_high refer to each frequency band specified in Table 5.5-1 in TS 36.101 [5] or in Table 5.2-1 in TS 38.101-1 [2].

NOTE 2: As exceptions, measurements with a level up to the applicable requirements defined in Table 6.6.3.1-2 in TS 36.101 [5] and Table 6.5.3.1-2 in TS 38.101-1 [2] are permitted for each assigned carrier used in the measurement due to 2nd, 3rd, 4th or 5th harmonic spurious emissions. Due to spreading of the harmonic emission the exception is also allowed for the first 1 MHz frequency range immediately outside the harmonic emission on both sides of the harmonic emission. This results in an overall exception interval centred at the harmonic emission of (2 MHz + N x LCRB x 180 kHz), where N is 2, 3, 4, 5 for the 2nd, 3rd, 4th or 5th harmonic respectively. The exception is allowed if the measurement bandwidth (MBW) totally or partially overlaps the overall exception interval.

NOTE 3: Applicable when co-existence with PHS system operating in 1884.5 – 1915.7 MHz

NOTE 4: Void.

NOTE 5: These requirements also apply for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1, Table 6.6.3.1A-1 in TS 36.101 [5] or in Table 6.5.3.1-1 in TS 38.101-1 [2] from the edge of the channel bandwidth.

NOTE 6: This requirement is applicable for any channel bandwidths within the range 2500 – 2570 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 2560.5 – 2562.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 2552 – 2560 MHz the requirement is applicable only for an uplink transmission bandwidth less than or equal to 54 RB.

NOTE 7: For these adjacent bands, the emission limit could imply risk of harmful interference to UE(s) operating in the protected operating band.

NOTE 8: This requirement is applicable for any channel bandwidths within the range 1920 – 1980 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 1927.5 – 1929.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 1930 – 1938 MHz the requirement is applicable only for an uplink

NOTE 9: Applicable when the assigned E-UTRA or NR carrier is confined within 718 MHz and 748 MHz and when the channel bandwidth used is 5 or 10 MHz.

NOTE 10: As exceptions, measurements with a level up to the applicable requirement of -38 dBm/MHz is permitted for each assigned E-UTRA carrier used in the measurement due to 2nd harmonic spurious emissions. An exception is allowed if there is at least one individual RB within the transmission bandwidth (see Figure 5.6-1) for which the 2nd harmonic totally or partially overlaps the measurement bandwidth (MBW).

NOTE 11: As exceptions, measurements with a level up to the applicable requirement of -36 dBm/MHz is permitted for each assigned E-UTRA carrier used in the measurement due to 3rd harmonic spurious emissions. An exception is allowed if there is at least one individual RB within the transmission bandwidth (see Figure 5.6-1) for which the 3rd harmonic totally or partially overlaps the measurement bandwidth (MBW).

NOTE 12: This requirement is applicable only for the following cases: A: for carriers of 5 MHz channel bandwidth when carrier centre frequency (Fc) is within the range 902.5 MHz ≤ Fc < 907.5 MHz with an uplink transmission bandwidth less than or equal to 20 RB; B: for carriers of 5 MHz channel bandwidth when carrier centre frequency (Fc) is within the range 907.5 MHz ≤ Fc ≤ 912.5 MHz without any restriction on uplink transmission bandwidth; C: for carriers of 10 MHz channel bandwidth when carrier centre frequency (Fc) is Fc = 910 MHz with an uplink transmission bandwidth less than or equal to 32 RB with RBstart > 3.

NOTE 13: Void.

NOTE 14: This requirement is applicable for 5 and 10 MHz E-UTRA or NR channel bandwidth allocated within 718-728MHz. For carriers of 10 MHz bandwidth, this requirement applies for an uplink transmission bandwidth less than or equal to 30 RB with RBstart > 1 and RBstart < 48.

NOTE 15: Void.

NOTE 16: This requirement is applicable for any channel bandwidths within the range 1920 – 1980 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 1927.5 – 1929.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 1930 – 1938 MHz the requirement is applicable only for an uplink transmission bandwidth less than or equal to 54 RB.

NOTE 17: This requirement is applicable in the case of a 10 MHz E-UTRA carrier confined within 703 MHz and 733 MHz, otherwise the requirement of -25 dBm with a measurement bandwidth of 8 MHz applies.

NOTE 18: This requirement is only applicable for E-UTRA carriers with bandwidth confined within 1885 – 1920 MHz (requirement for carriers with at least 1RB confined within 1880 – 1885 MHz is not specified). This requirement applies for an uplink transmission bandwidth less than or equal to 54 RB for E-UTRA carriers of 15 MHz bandwidth when carrier centre frequency is within the range 1892.5 – 1894.5 MHz and for E-UTRA carriers of 20 MHz bandwidth when carrier centre frequency is within the range 1895 – 1903 MHz.

NOTE 19: Void.

NOTE 20: Void.

NOTE 21: Void.

Table 6.5B.3.3.2.5-3: Requirements for inter-band within FR1 for Rel-17

EN-DC Configuration

Spurious emission

Protected band

Frequency range (MHz)

Maximum Level (dBm)

MBW (MHz)

NOTE

DC_1_n3

E-UTRA Band 1, 11, 21, 32, 43, 50, 65, 74, 75

FDL_low

FDL_high

-50

1

NR Band 77, 78

FDL_low

FDL_high

-50

1

2

DC_1_n28

E-UTRA Band 7, 31, 41, 72, 73

NR Band n79

FDL_low

FDL_high

-50

1

E-UTRA Band 42, 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

Frequency range

470

694

-42

8

5, 17

Frequency range

470

710

-26.2

6

14

DC_1_n77

E-UTRA Band 1, 3, 11, 21, 34, 65, 74

FDL_low

FDL_high

-50

1

 

Frequency range

1880

1895

-40

1

5, 8

Frequency range

1895

1915

-15.5

5

5, 7, 8

Frequency range

1915

1920

1.6

5

5, 7, 8

DC_1_n78

E-UTRA Band 3, 11, 21, 74

FDL_low

FDL_high

-50

1

Frequency range

1880

1895

-40

1

5, 8

DC_1_n79

E-UTRA Band 5, 7, 8, 18, 19, 26, 28, 41

FDL_low

FDL_high

-50

1

DC_2_n5

E-UTRA Band 42, 48

NR band n77

FDL_low

FDL_high

-50

1

E-UTRA Band 41, 43

FDL_low

FDL_high

-50

1

2

DC_2_n41

E-UTRA Band 12, 13, 14, 17, 28, 29, 42, 71

FDL_low

FDL_high

-50

1

E-UTRA Bands 2

FDL_low

FDL_high

-50

1

5

DC_2_n66

E-UTRA Band 4, 10, 24, 50, 66, 70, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

5

E-UTRA Band 42, 48

FDL_low

FDL_high

-50

1

2

DC_2_n77

E-UTRA Band 4, 65, 66, 70

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

2

DC_2_n71

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

DC_2_n78

E-UTRA Band 24, 50, 51, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

2

DC_3_n1

E-UTRA Band 1, 11, 21, 32, 50, 65, 74, 75

FDL_low

FDL_high

-50

1

DC_3_n7

E-UTRA Band 5, 8, 20, 26, 27, 28, 44, 67

FDL_low

FDL_high

-50

1

E-UTRA Band 42

FDL_low

FDL_high

-50

1

2

DC_3_n28

NR band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 7, 41

FDL_low

FDL_high

-50

1

DC_3_n41

E-UTRA Band 5, 8, 20, 26, 27, 28, 44

FDL_low

FDL_high

-50

1

E-UTRA Band 18, 19

FDL_low

FDL_high

-50

1

14, 20

E-UTRA Band 42,

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

DC_3_n77

E-UTRA Band 1, 3, 28, 34, 39, 40, 65, 74

FDL_low

FDL_high

-50

1

 

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n78

E-UTRA Band 3, 34, 39

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_3_n79

E-UTRA Band 5, 8, 11, 18, 19, 21, 41, 74

FDL_low

FDL_high

-50

1

DC_5_n2

E-UTRA Band 42

FDL_low

FDL_high

-50

1

E-UTRA Band 41, 43

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_5_n66

E-UTRA Band 5, 6, 7, 8, 38

FDL_low

FDL_high

-50

1

E-UTRA Band 26

859

869

-27

1

E-UTRA Band 41, 42, 52

FDL_low

FDL_high

-50

1

2

NR Band n77

DC_5_n77

E-UTRA Band 2, 4, 25, 30, 40, 65, 66, 70

FDL_low

FDL_high

-50

1

 

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_5_n78

E-UTRA Band 1, 2, 3, 4, 7, 25, 34, 38, 65, 66, 70

FDL_low

FDL_high

-50

1

 

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2, 7

DC_7_n1

E-UTRA Band 32, 50, 51, 75, 76 or NR Band n79

FDL_low

FDL_high

-50

1

DC_7_n3

E-UTRA Band 5, 8, 20, 26, 27, 28, 67, 68

FDL_low

FDL_high

-50

1

E-UTRA band 42, 52

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

DC_7_n28

E-UTRA Band 3

FDL_low

FDL_high

-50

1

NR band n78

FDL_low

FDL_high

-50

1

2

DC_7_n78

E-UTRA Band 3, 5, 8, 11, 18, 19, 20, 21, 26, 27, 28, 32, 50, 51, 67, 68, 74, 75, 76

FDL_low

FDL_high

-50

1

DC_7_n66

E-UTRA Band 5, 12, 13, 14, 17, 26, 27, 28, 29, 85

FDL_low

FDL_high

-50

1

E-UTRA band 42

FDL_low

FDL_high

-50

1

2

DC_8_n1

E-UTRA Band 43 or NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

DC_8_n3

E-UTRA Band 20, 28, 38, 44

FDL_low

FDL_high

-50

1

E-UTRA Band 7, 22, 41, 42, 43 or NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

Frequency range

860

890

-40

1

5, 12

DC_8_n41

E-UTRA Band 28

FDL_low

FDL_high

-50

1

 

E-UTRA band 3, 42, 52

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

E-UTRA Band 8

FDL_low

FDL_high

-50

1

5

Frequency range

860

890

-40

1

5, 12

DC_8_n77

E-UTRA Band 1, 32, 33, 34, 38, 39, 40,50, 65, 69, 74, 75

FDL_low

FDL_high

-50

1

E-UTRA band 3, 7, 41

FDL_low

FDL_high

-50

1

2

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

12

Frequency range

1884.5

1915.7

-41

0.3

3, 12

DC_8_n78

E-UTRA band 34, 39, 40, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 3, 7, 41

FDL_low

FDL_high

-50

1

2

E-UTRA Band 11, 21

FDL_low

FDL_high

-50

1

12

Frequency range

1884.5

1915.7

-41

0.3

3, 12

DC_11_n77

E-UTRA Band 1, 3, 18, 19, 28, 34, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_11_n78

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_11_n79

E-UTRA Band 1, 3, 34, 42, 65

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_12_n66

E-UTRA Band 41, 53

FDL_low

FDL_high

-50

1

NR band n77

FDL_low

FDL_high

-50

1

2

DC_12_n78

E-UTRA Band 2, 7, 25, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 4, 66

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_13_n2

E-UTRA Band 41

FDL_low

FDL_high

-50

1

DC_13_n66

E-UTRA Band 41, 53

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_13_n77

E-UTRA Band 2, 4, 10, 25, 41, 66, 70

FDL_low

FDL_high

-50

1

 

E-UTRA Band 30

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

DC_14_n2

E-UTRA Band 41

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

DC_14_n66

E-UTRA Band 41

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

DC_19_n1

E-UTRA Band 42

NR Band n79

FDL_low

FDL_high

-50

1

NR Band n77, n78

FDL_low

FDL_high

-50

1

2

DC_19_n77

E-UTRA Band 1, 3, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_19_n78

E-UTRA Band 1, 3, 34, 65

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_19_n79

E-UTRA Band 42

FDL_low

FDL_high

-50

1

DC_20_n1

E-UTRA Band 22, 42, 43

FDL_low

FDL_high

-50

1

NR Band 77, 78

FDL_low

FDL_high

-50

1

2

DC_20_n3

E-UTRA Band 7, 8

FDL_low

FDL_high

-50

1

E-UTRA Band 38, 42, 52

FDL_low

FDL_high

-50

1

2

DC_20_n28

E-UTRA Band 8

FDL_low

FDL_high

-50

1

DC_20_n78

E-UTRA Band 1, 3, 7, 33, 34, 65

FDL_low

FDL_high

-50

1

 

E-UTRA Band 38, 69

FDL_low

FDL_high

-50

1

2

DC_21_n1

E-UTRA Band 40, 42

NR Band n78, n79

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

2

Frequency range

945

960

-50

1

DC_21_n77

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

945

960

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_21_n78

E-UTRA Band 1, 3, 18, 19, 28, 34, 40, 65

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_21_n79

E-UTRA Band 3, 21, 34, 42

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_25_n41

E-UTRA Band 12, 13, 14, 17, 28, 29, 42, 71

FDL_low

FDL_high

-50

1

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_26_n41

E-UTRA Band 3, 5, 18, 19, 26, 42

FDL_low

FDL_high

-50

1

Frequency range

799

803

-40

1

5

Frequency range

945

960

-50

1

DC_26_n77

E-UTRA Band 1, 3, 34, 39, 40, 65

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

Frequency range

2595

2645

-50

1

DC_26_n78

E-UTRA Band 1, 3, 34, 39, 65

FDL_low

FDL_high

-50

1

E-UTRA Band 41

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3

Frequency range

2545

2575

-50

1

2

Frequency range

2595

2645

-50

1

DC_28_n3

NR Band n77

FDL_low

FDL_high

-50

1

2

E-UTRA Band 7, 41

FDL_low

FDL_high

-50

1

DC_28A_n77

E-UTRA Band 3, 7, 34, 39, 40, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 65

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

Frequency range

1884.5

1915.7

-41

0.3

3, 9

DC_28_n78

DC_28_n83_ULSUP-TDM_n78

E-UTRA Band 3, 7, 34, 39, 40, 41

FDL_low

FDL_high

-50

1

E-UTRA Band 1, 65

FDL_low

FDL_high

-50

1

2

E-UTRA Band 1

FDL_low

FDL_high

-50

1

9, 11

Frequency range

1884.5

1915.7

-41

0.3

3

DC_28_n79

E-UTRA Band 42

FDL_low

FDL_high

-50

1

2

DC_30_n5

E-UTRA Band 71

FDL_low

FDL_high

-50

1

NR band n77

FDL_low

FDL_high

-50

1

2

DC_39_n41

E-UTRA Band 42, 44

FDL_low

FDL_high

-50

1

NR Band n77, n78, n79

FDL_low

FDL_high

-50

1

2

DC_39_n79

E-UTRA Band 8, 28, 41, 44

FDL_low

FDL_high

-50

1

DC_40_n1

E-UTRA Band 7, 31, 32, 41, 45, 50, 72, 73, 74, 75

FDL_low

FDL_high

-50

1

 

DC_40_n41

Bands 1, 34, 39, 65

FDL_low

FDL_high

-50

1

NR Band n79

FDL_low

FDL_high

-50

1

2

Frequency range

1884.5

1915.7

-41

0.3

3, 19

DC_40_n78

E-UTRA Band 5, 8, 11, 18, 19, 20, 21, 26, 27, 28, 32, 44, 45, 50, 51, 74, 75, 76

FDL_low

FDL_high

-50

1

NR Band n79

FDL_low

FDL_high

-50

1

2

DC_41_n77

E-UTRA Band 3, 5, 8, 11, 18, 19, 21, 26, 28, 33, 34, 39, 44, 45, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_41_n78

E-UTRA Band 3, 5, 8, 11, 18, 19, 21, 26, 28, 34, 39, 44, 45, 74

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_41_n79

E-UTRA Band 1, 3, 5, 8, 9, 18, 19, 26, 28, 34, 40, 44, 65

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_48_n5

E-UTRA Band 25, 70

FDL_low

FDL_high

-50

1

Frequency range

1884.5

1915.7

-41

0.3

3

DC_48_n66

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

DC_66_n2

E-UTRA Band 4, 10, 22, 24, 50, 66, 70, 74

FDL_low

FDL_high

-50

1

E-UTRA Band 2, 25

FDL_low

FDL_high

-50

1

5

E-UTRA Band 42, 43

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_66_n5

E-UTRA Band 5, 6, 7, 8, 26, 38

FDL_low

FDL_high

-50

1

E-UTRA Band 41, 42, 52

NR Band n77

FDL_low

FDL_high

-50

1

2

DC_66_n41

E-UTRA Band 5, 12, 13, 14, 17, 26, 27, 28, 29, 43, 85

FDL_low

FDL_high

-50

1

 

E-UTRA Band 42, 48,
NR band n77

FDL_low

FDL_high

-50

1

2

DC_66_n77

E-UTRA Band 2, 4, 12, 13, 14, 17, 29, 30, 65, 66, 70, 71

FDL_low

FDL_high

-50

1

 

DC_66_n78

E-UTRA Band 3, 34, 39

FDL_low

FDL_high

-50

1

NOTE 1: FDL_low and FDL_high refer to each frequency band specified in Table 5.5-1 in TS 36.101 [4] or in Table 5.2-1 in TS 38.101-1 [2].

NOTE 2: As exceptions, measurements with a level up to the applicable requirements defined in Table 6.6.3.1-2 in TS 36.101 [4] and Table 6.5.3.1-2 in TS 38.101-1 [2] are permitted for each assigned carrier used in the measurement due to 2nd, 3rd, 4th or 5th harmonic spurious emissions. Due to spreading of the harmonic emission the exception is also allowed for the first 1 MHz frequency range immediately outside the harmonic emission on both sides of the harmonic emission. This results in an overall exception interval centred at the harmonic emission of (2 MHz + N x LCRB x 180 kHz), where N is 2, 3, 4, 5 for the 2nd, 3rd, 4th or 5th harmonic respectively. The exception is allowed if the measurement bandwidth (MBW) totally or partially overlaps the overall exception interval.

NOTE 3: Applicable when co-existence with PHS system operating in 1884.5 – 1915.7 MHz

NOTE 4: Void

NOTE 5: These requirements also apply for the frequency ranges that are less than FOOB (MHz) in Table 6.6.3.1-1, Table 6.6.3.1A-1 in TS 36.101 [4] or in Table 6.5.3.1-1 in TS 38.101-1 [2] from the edge of the channel bandwidth.

NOTE 6: This requirement is applicable for any channel bandwidths within the range 2500 – 2570 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 2560.5 – 2562.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 2552 – 2560 MHz the requirement is applicable only for an uplink transmission bandwidth less than or equal to 54 RB.

NOTE 7: For these adjacent bands, the emission limit could imply risk of harmful interference to UE(s) operating in the protected operating band.

NOTE 8: This requirement is applicable for any channel bandwidths within the range 1920 – 1980 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 1927.5 – 1929.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 1930 – 1938 MHz the requirement is applicable only for an uplink

NOTE 9: Applicable when the assigned E-UTRA or NR carrier is confined within 718 MHz and 748 MHz and when the channel bandwidth used is 5 or 10 MHz.

NOTE 10: As exceptions, measurements with a level up to the applicable requirement of -38 dBm/MHz is permitted for each assigned E-UTRA carrier used in the measurement due to 2nd harmonic spurious emissions. An exception is allowed if there is at least one individual RB within the transmission bandwidth (see Figure 5.6-1) for which the 2nd harmonic totally or partially overlaps the measurement bandwidth (MBW).

NOTE 11: As exceptions, measurements with a level up to the applicable requirement of -36 dBm/MHz is permitted for each assigned E-UTRA carrier used in the measurement due to 3rd harmonic spurious emissions. An exception is allowed if there is at least one individual RB within the transmission bandwidth (see Figure 5.6-1) for which the 3rd harmonic totally or partially overlaps the measurement bandwidth (MBW).

NOTE 12: This requirement is applicable only for the following cases: A: for carriers of 5 MHz channel bandwidth when carrier centre frequency (Fc) is within the range 902.5 MHz ≤ Fc < 907.5 MHz with an uplink transmission bandwidth less than or equal to 20 RB; B: for carriers of 5 MHz channel bandwidth when carrier centre frequency (Fc) is within the range 907.5 MHz ≤ Fc ≤ 912.5 MHz without any restriction on uplink transmission bandwidth; C: for carriers of 10 MHz channel bandwidth when carrier centre frequency (Fc) is Fc = 910 MHz with an uplink transmission bandwidth less than or equal to 32 RB with RBstart > 3.

NOTE 13: Void

NOTE 14: This requirement is applicable for 5 and 10 MHz E-UTRA or NR channel bandwidth allocated within 718-728MHz. For carriers of 10 MHz bandwidth, this requirement applies for an uplink transmission bandwidth less than or equal to 30 RB with RBstart > 1 and RBstart < 48.

NOTE 15: Void

NOTE 16: This requirement is applicable for any channel bandwidths within the range 1920 – 1980 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 1927.5 – 1929.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 1930 – 1938 MHz the requirement is applicable only for an uplink transmission bandwidth less than or equal to 54 RB.

NOTE 17: This requirement is applicable in the case of a 10 MHz E-UTRA or NR carrier confined within 703 MHz and 733 MHz, otherwise the requirement of -25 dBm with a measurement bandwidth of 8 MHz applies.

NOTE 18: This requirement is only applicable for E-UTRA carriers with bandwidth confined within 1885 – 1920 MHz (requirement for carriers with at least 1RB confined within 1880 – 1885 MHz is not specified). This requirement applies for an uplink transmission bandwidth less than or equal to 54 RB for E-UTRA carriers of 15 MHz bandwidth when carrier center frequency is within the range 1892.5 – 1894.5 MHz and for E-UTRA carriers of 20 MHz bandwidth when carrier center frequency is within the range 1895 – 1903 MHz.

NOTE 19: Void

NOTE 20: Void.

NOTE 21: Void

NOTE 22: This requirement is applicable for power class 3 UE for any channel bandwidths within the range 2570 – 2615 MHz with the following restriction: for carriers of 15 MHz bandwidth when carrier centre frequency is within the range 2605.5 – 2607.5 MHz and for carriers of 20 MHz bandwidth when carrier centre frequency is within the range 2597 – 2605 MHz the requirement is applicable only for an uplink transmission bandwidth less than or equal to 54 RB.

6.5B.3.3a Inter-band NE-DC within FR1

6.5B.3.3a.1 General Spurious Emissions for Inter-band NE-DC within FR1

No exception requirements applicable to NR or E-UTRA.

No test case details are specified. The requirements for NR carrier(s) in this test case are tested in 6.5.3.1 and 6.5A.3.1 of TS 38.521-1 [8], and the requirements for LTE carrier(s) in this test case are tested in 6.6.3.1 and 6.6.3.1A of TS 36.521-1 [10]. Neither NR carrier(s) nor LTE carrier(s) needs to be tested again.

6.5B.3.3a.2 Spurious emission band UE co-existence for Inter-band NE-DC within FR1

FFS

6.5B.3.4 Spurious Emissions for Inter-band including FR2

Editor’s note: This clause is complete for Band n257, n258, n260 and n261. The following aspects are either missing or not yet determined:

– The referred test case 6.5.3 in TS 38.521-2 [9] is incomplete for frequency above 80 GHz.

6.5B.3.4.1 General Spurious Emissions for Inter-band including FR2 (1 NR CC)

6.5B.3.4.1.1 Test purpose

Same test purpose as in clause 6.5.3.1.1 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.1.2 Test applicability

This test case applies to all types of E-UTRA UE release 15 and forward, supporting inter-band EN-DC including FR2 with 1 NR UL CC.

6.5B.3.4.1.3 Minimum conformance requirements

Same minimum conformance requirements as in clause 6.5.3.1.3 in TS 38.521-2 [9] for the NR carrier.

No exception requirements applicable to NR or E-UTRA. LTE anchor agnostic approach is applied.

The normative reference for this requirement is TS 38.101-3 [4] clause 6.5B.3.4.

6.5B.3.4.1.4 Test description

6.5B.3.4.1.4.1 Initial conditions

Same test description as in clause 6.5.3.1.4 in TS 38.521-2 [9] for the NR carrier with the following exception:

The initial test configurations for E-UTRA band consist of environmental conditions, test frequencies, and channel bandwidths based on E-UTRA bands specified in Table 4.6-1. For Initial conditions as in clause 6.5.3.1.4.1 in TS 38.521-2 [9], the following steps will be added to configure E-UTRA component:

2.1 The parameter settings for E-UTRA cell are set up according to TS 36.508 [11] clause 4.4.3.

3.1 The E-UTRA downlink signal level, uplink signal level are set according to Table 4.7-1 and propagation conditions are set according to Annex B.0 of TS 36.521-1 [10].

Step 6 of Initial conditions as in clause 6.5.3.1.4.1 in TS 38.521-2 [9] is replaced by:

6. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508-1 [6] clause 4.5.

Same test procedure as in clause 6.5.3.1.4.1 in TS 38.521-2 [9] with the following steps added for E-UTRA component:

1.1 On the E-UTRA carrier, disable periodic and aperiodic CQI reports, disable SRS, set TimeAlignmentTimerDedicated IE to infinity and disable downlink and uplink scheduling, all as per Table 4.7-1 under clause 4.7.

6.5B.3.4.1.5 Test requirement

Same test requirement as in clause 6.5.3.1.5 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.1_1 General Spurious emissions for Inter-band EN-DC including FR2 (>1 NR CC)
6.5B.3.4.1_1.1 General Spurious emissions for Inter-band EN-DC including FR2 (2 NR CCs)

Editor’s note: The following aspects are either missing or not yet determined:

– The referred test case 6.5A.3.1.1 in TS 38.521-2 [9] is incomplete for:

▪ Bands other than n257, n258, n260 and n261

▪ Power classes 1, 2 and 4

for PC1, PC2 and PC4

6.5B.3.4.1_1.1.1 Test purpose

Same test purpose as in clause 6.5.3.1 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.1_1.1.2 Test applicability

This test case applies to all types of E-UTRA UE release 15 and forward, supporting inter-band EN-DC including FR2 with 2 NR UL CCs.

6.5B.3.4.1_1.1.3 Minimum conformance requirements

Same minimum conformance requirements as in clause 6.5.3.3 in TS 38.521-2 [9] for the NR carrier.

No exception requirements applicable to NR or E-UTRA. LTE anchor agnostic approach is applied.

The normative reference for this requirement is TS 38.101-3 [4] clause 6.4B.3.4.

6.5B.3.4.1_1.1.4 Test description

6.5B.3.4.1_1.1.4.1 Initial condition

Same test description as in clause 6.5A.3.1.1.4 in TS 38.521-2 [9] for the NR carrier with the following exception:

The initial test configurations for E-UTRA band consist of environmental conditions, test frequencies, and channel bandwidths based on E-UTRA bands specified in Table 4.7-1.

For Initial conditions as in clause 6.5A.3.1.1.4.1 in TS 38.521-2 [9], the following steps will be added to configure E-UTRA component:

2.1. The parameter settings for E-UTRA cell are set up according to TS 36.508 [11] clause 4.4.3.

3.1. The E-UTRA downlink signal level, uplink signal level are set according to Table 4.7-1 and propagation conditions are set according to Annex B.0 of TS 36.521-1 [10].

Step 6 of Initial conditions as in clause 6.5A.3.1.1.4.1 in TS 38.521-2 [9] is replaced by:

6. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508-1 [6] clause 4.5.

Same test procedure as in clause 6.5A.3.1.1.4.2 in TS 38.521-2 [9] with the following steps added for E-UTRA component:

1.1 On the E-UTRA carrier, disable periodic and aperiodic CQI reports, disable SRS, set TimeAlignmentTimerDedicated IE to infinity and disable downlink and uplink scheduling, all as per Table 4.7-1 under clause 4.7.

6.5B.3.4.1_1.1.5 Test Requirements

Same test requirement as in clause 6.5A.3.1.1.5 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.1_1.2 General Spurious emissions for Inter-band EN-DC including FR2 (3 NR CCs)

Editor’s note: The following aspects are either missing or not yet determined:

– The referred test case 6.5A.3.1.2 in TS 38.521-2 [9] is incomplete for:

▪ Bands other than n257, n258, n260 and n261

▪ Power classes 1, 2 and 4

for PC1, PC2 and PC4

6.5B.3.4.1_1.2.1 Test purpose

Same test purpose as in clause 6.5.3.1 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.1_1.2.2 Test applicability

This test case applies to all types of E-UTRA UE release 15 and forward, supporting inter-band EN-DC including FR2 with 3 NR UL CCs.

6.5B.3.4.1_1.2.3 Minimum conformance requirements

Same minimum conformance requirements as in clause 6.5.3.3 in TS 38.521-2 [9] for the NR carrier.

No exception requirements applicable to NR or E-UTRA. LTE anchor agnostic approach is applied.

The normative reference for this requirement is TS 38.101-3 [4] clause 6.4B.3.4.

6.5B.3.4.1_1.2.4 Test description

6.5B.3.4.1_1.2.4.1 Initial condition

Same test description as in clause 6.5A.3.1.2.4 in TS 38.521-2 [9] for the NR carrier with the following exception:

The initial test configurations for E-UTRA band consist of environmental conditions, test frequencies, and channel bandwidths based on E-UTRA bands specified in Table 4.7-1.

For Initial conditions as in clause 6.5A.3.1.2.4.1 in TS 38.521-2 [9], the following steps will be added to configure E-UTRA component:

2.1. The parameter settings for E-UTRA cell are set up according to TS 36.508 [11] clause 4.4.3.

3.1. The E-UTRA downlink signal level, uplink signal level are set according to Table 4.7-1 and propagation conditions are set according to Annex B.0 of TS 36.521-1 [10].

Step 6 of Initial conditions as in clause 6.5A.3.1.2.4.1 in TS 38.521-2 [9] is replaced by:

6. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508-1 [6] clause 4.5.

Same test procedure as in clause 6.5A.3.1.2.4.2 in TS 38.521-2 [9] with the following steps added for E-UTRA component:

1.1 On the E-UTRA carrier, disable periodic and aperiodic CQI reports, disable SRS, set TimeAlignmentTimerDedicated IE to infinity and disable downlink and uplink scheduling, all as per Table 4.7-1 under clause 4.7.

6.5B.3.4.1_1.2.5 Test Requirements

Same test requirement as in clause 6.5A.3.1.2.5 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.1_1.3 General Spurious emissions for Inter-band EN-DC including FR2 (4 NR CCs)

Editor’s note: The following aspects are either missing or not yet determined:

– The referred test case 6.5A.3.1.3 in TS 38.521-2 [9] is incomplete for:

▪ Bands other than n257, n258, n260 and n261

▪ Power classes 1, 2 and 4

for PC1, PC2 and PC4

6.5B.3.4.1_1.3.1 Test purpose

Same test purpose as in clause 6.5.3.1 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.1_1.3.2 Test applicability

This test case applies to all types of E-UTRA UE release 15 and forward, supporting inter-band EN-DC including FR2 with 4 NR UL CCs.

6.5B.3.4.1_1.3.3 Minimum conformance requirements

Same minimum conformance requirements as in clause 6.5.3.3 in TS 38.521-2 [9] for the NR carrier.

No exception requirements applicable to NR or E-UTRA. LTE anchor agnostic approach is applied.

The normative reference for this requirement is TS 38.101-3 [4] clause 6.4B.3.4.

6.5B.3.4.1_1.3.4 Test description

6.5B.3.4.1_1.3.4.1 Initial condition

Same test description as in clause 6.5A.3.1.3.4 in TS 38.521-2 [9] for the NR carrier with the following exception:

The initial test configurations for E-UTRA band consist of environmental conditions, test frequencies, and channel bandwidths based on E-UTRA bands specified in Table 4.7-1.

For Initial conditions as in clause 6.5A.3.1.3.4.1 in TS 38.521-2 [9], the following steps will be added to configure E-UTRA component:

2.1. The parameter settings for E-UTRA cell are set up according to TS 36.508 [11] clause 4.4.3.

3.1. The E-UTRA downlink signal level, uplink signal level are set according to Table 4.7-1 and propagation conditions are set according to Annex B.0 of TS 36.521-1 [10].

Step 6 of Initial conditions as in clause 6.5A.3.1.3.4.1 in TS 38.521-2 [9] is replaced by:

6. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508-1 [6] clause 4.5.

Same test procedure as in clause 6.5A.3.1.3.4.2 in TS 38.521-2 [9] with the following steps added for E-UTRA component:

1.1 On the E-UTRA carrier, disable periodic and aperiodic CQI reports, disable SRS, set TimeAlignmentTimerDedicated IE to infinity and disable downlink and uplink scheduling, all as per Table 4.7-1 under clause 4.7.

6.5B.3.4.1_1.3.5 Test Requirements

Same test requirement as in clause 6.5A.3.1.3.5 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.1_1.4 General Spurious emissions for Inter-band EN-DC including FR2 (5 NR CCs)

Editor’s note: The test case is incomplete. The following aspects are either missing or not yet determined:

– The referred test case 6.5A.3.1.4 in TS 38.521-2 [9] is incomplete for:

▪ Bands other than n257, n258, n260 and n261

▪ Power classes 1, 2 and 4

– Measurement Uncertainties and Test Tolerances is incomplete.

6.5B.3.4.1_1.4.1 Test purpose

Same test purpose as in clause 6.5.3.1 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.1_1.4.2 Test applicability

This test case applies to all types of E-UTRA UE release 15 and forward, supporting inter-band EN-DC including FR2 with 5 NR UL CCs.

6.5B.3.4.1_1.4.3 Minimum conformance requirements

Same minimum conformance requirements as in clause 6.5.3.3 in TS 38.521-2 [9] for the NR carrier.

No exception requirements applicable to NR or LTE. LTE anchor agnostic approach is applied.

The normative reference for this requirement is TS 38.101-3 [4] clause 6.5B.3.4.

6.5B.3.4.1_1.4.4 Test description

6.5B.3.4.1_1.4.4.1 Initial condition

Same test description as in clause 6.5A.3.1.4.4 in TS 38.521-2 [9] for the NR carrier with the following exception:

The initial test configurations for E-UTRA band consist of environmental conditions, test frequencies, and channel bandwidths based on E-UTRA bands specified in Table 4.7-1.

For Initial conditions as in clause 6.5A.3.1.1.4.1 in TS 38.521-2 [9], the following steps will be added to configure E-UTRA component:

2.1. The parameter settings for E-UTRA cell are set up according to TS 36.508 [11] clause 4.4.3.

3.1. The E-UTRA downlink signal level, uplink signal level are set according to Table 4.7-1 and propagation conditions are set according to Annex B.0 of TS 36.521-1 [10].

Step 6 of Initial conditions as in clause 6.5A.3.1.1.4.1 in TS 38.521-2 [9] is replaced by:

6. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508-1 [6] clause 4.5.

Same test procedure as in clause 6.5A.3.1.1.4.2 in TS 38.521-2 [9] with the following steps added for E-UTRA component:

1.1 On the E-UTRA carrier, disable periodic and aperiodic CQI reports, disable SRS, set TimeAlignmentTimerDedicated IE to infinity and disable downlink and uplink scheduling, all as per Table 4.7-1 under clause 4.7.

6.5B.3.4.1_1.4.5 Test Requirements

Same test requirement as in clause 6.5A.3.1.4.5 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.1_1.5 General Spurious emissions for Inter-band EN-DC including FR2 (6 NR CCs)

Editor’s note: The test case is incomplete. The following aspects are either missing or not yet determined:

– The referred test case 6.5A.3.1.5 in TS 38.521-2 [9] is incomplete for:

▪ Bands other than n257, n258, n260 and n261

▪ Power classes 1, 2 and 4

– Measurement Uncertainties and Test Tolerances is incomplete.

6.5B.3.4.1_1.5.1 Test purpose

Same test purpose as in clause 6.5.3.1 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.1_1.5.2 Test applicability

This test case applies to all types of E-UTRA UE release 15 and forward, supporting inter-band EN-DC including FR2 with 6 NR UL CCs.

6.5B.3.4.1_1.5.3 Minimum conformance requirements

Same minimum conformance requirements as in clause 6.5.3.3 in TS 38.521-2 [9] for the NR carrier.

No exception requirements applicable to NR or LTE. LTE anchor agnostic approach is applied.

The normative reference for this requirement is TS 38.101-3 [4] clause 6.5B.3.4.

6.5B.3.4.1_1.5.4 Test description

6.5B.3.4.1_1.5.4.1 Initial condition

Same test description as in clause 6.5A.3.1.5.4 in TS 38.521-2 [9] for the NR carrier with the following exception:

The initial test configurations for E-UTRA band consist of environmental conditions, test frequencies, and channel bandwidths based on E-UTRA bands specified in Table 4.7-1.

For Initial conditions as in clause 6.5A.3.1.1.4.1 in TS 38.521-2 [9], the following steps will be added to configure E-UTRA component:

2.1. The parameter settings for E-UTRA cell are set up according to TS 36.508 [11] clause 4.4.3.

3.1. The E-UTRA downlink signal level, uplink signal level are set according to Table 4.7-1 and propagation conditions are set according to Annex B.0 of TS 36.521-1 [10].

Step 6 of Initial conditions as in clause 6.5A.3.1.1.4.1 in TS 38.521-2 [9] is replaced by:

6. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508-1 [6] clause 4.5.

Same test procedure as in clause 6.5A.3.1.1.4.2 in TS 38.521-2 [9] with the following steps added for E-UTRA component:

1.1 On the E-UTRA carrier, disable periodic and aperiodic CQI reports, disable SRS, set TimeAlignmentTimerDedicated IE to infinity and disable downlink and uplink scheduling, all as per Table 4.7-1 under clause 4.7.

6.5B.3.4.1_1.5.5 Test Requirements

Same test requirement as in clause 6.5A.3.1.5.5 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.1_1.6 General Spurious emissions for Inter-band EN-DC including FR2 (7 NR CCs)

Editor’s note: The test case is incomplete. The following aspects are either missing or not yet determined:

– The referred test case 6.5A.3.1.6 in TS 38.521-2 [9] is incomplete for:

▪ Bands other than n257, n258, n260 and n261

▪ Power classes 1, 2 and 4

– Measurement Uncertainties and Test Tolerances is incomplete.

6.5B.3.4.1_1.6.1 Test purpose

Same test purpose as in clause 6.5.3.1 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.1_1.6.2 Test applicability

This test case applies to all types of E-UTRA UE release 15 and forward, supporting inter-band EN-DC including FR2 with 7 NR UL CCs.

6.5B.3.4.1_1.6.3 Minimum conformance requirements

Same minimum conformance requirements as in clause 6.5.3.3 in TS 38.521-2 [9] for the NR carrier.

No exception requirements applicable to NR or LTE. LTE anchor agnostic approach is applied.

The normative reference for this requirement is TS 38.101-3 [4] clause 6.5B.3.4.

6.5B.3.4.1_1.6.4 Test description

6.5B.3.4.1_1.6.4.1 Initial condition

Same test description as in clause 6.5A.3.1.6.4 in TS 38.521-2 [9] for the NR carrier with the following exception:

The initial test configurations for E-UTRA band consist of environmental conditions, test frequencies, and channel bandwidths based on E-UTRA bands specified in Table 4.7-1.

For Initial conditions as in clause 6.5A.3.1.1.4.1 in TS 38.521-2 [9], the following steps will be added to configure E-UTRA component:

2.1. The parameter settings for E-UTRA cell are set up according to TS 36.508 [11] clause 4.4.3.

3.1. The E-UTRA downlink signal level, uplink signal level are set according to Table 4.7-1 and propagation conditions are set according to Annex B.0 of TS 36.521-1 [10].

Step 6 of Initial conditions as in clause 6.5A.3.1.1.4.1 in TS 38.521-2 [9] is replaced by:

6. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508-1 [6] clause 4.5.

Same test procedure as in clause 6.5A.3.1.1.4.2 in TS 38.521-2 [9] with the following steps added for E-UTRA component:

1.1 On the E-UTRA carrier, disable periodic and aperiodic CQI reports, disable SRS, set TimeAlignmentTimerDedicated IE to infinity and disable downlink and uplink scheduling, all as per Table 4.7-1 under clause 4.7.

6.5B.3.4.1_1.6.5 Test Requirements

Same test requirement as in clause 6.5A.3.1.6.5 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.1_1.7 General Spurious emissions for Inter-band EN-DC including FR2 (8 NR CCs)

Editor’s note: The test case is incomplete. The following aspects are either missing or not yet determined:

– The referred test case 6.5A.3.1.7 in TS 38.521-2 [9] is incomplete for:

▪ Bands other than n257, n258, n260 and n261

▪ Power classes 1, 2 and 4

– Measurement Uncertainties and Test Tolerances is incomplete.

6.5B.3.4.1_1.7.1 Test purpose

Same test purpose as in clause 6.5.3.1 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.1_1.7.2 Test applicability

This test case applies to all types of E-UTRA UE release 15 and forward, supporting inter-band EN-DC including FR2 with 8 NR UL CCs.

6.5B.3.4.1_1.7.3 Minimum conformance requirements

Same minimum conformance requirements as in clause 6.5.3.3 in TS 38.521-2 [9] for the NR carrier.

No exception requirements applicable to NR or LTE. LTE anchor agnostic approach is applied.

The normative reference for this requirement is TS 38.101-3 [4] clause 6.5B.3.4.

6.5B.3.4.1_1.7.4 Test description

6.5B.3.4.1_1.7.4.1 Initial condition

Same test description as in clause 6.5A.3.1.7.4 in TS 38.521-2 [9] for the NR carrier with the following exception:

The initial test configurations for E-UTRA band consist of environmental conditions, test frequencies, and channel bandwidths based on E-UTRA bands specified in Table 4.7-1.

For Initial conditions as in clause 6.5A.3.1.1.4.1 in TS 38.521-2 [9], the following steps will be added to configure E-UTRA component:

2.1. The parameter settings for E-UTRA cell are set up according to TS 36.508 [11] clause 4.4.3.

3.1. The E-UTRA downlink signal level, uplink signal level are set according to Table 4.7-1 and propagation conditions are set according to Annex B.0 of TS 36.521-1 [10].

Step 6 of Initial conditions as in clause 6.5A.3.1.1.4.1 in TS 38.521-2 [9] is replaced by:

6. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508-1 [6] clause 4.5.

Same test procedure as in clause 6.5A.3.1.1.4.2 in TS 38.521-2 [9] with the following steps added for E-UTRA component:

1.1 On the E-UTRA carrier, disable periodic and aperiodic CQI reports, disable SRS, set TimeAlignmentTimerDedicated IE to infinity and disable downlink and uplink scheduling, all as per Table 4.7-1 under clause 4.7.

6.5B.3.4.1_1.7.5 Test Requirements

Same test requirement as in clause 6.5A.3.1.7.5 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.1D General Spurious Emissions for inter-band EN-DC including FR2 for UL MIMO

Editor’s note: This clause is incomplete. The following aspects are either missing or not yet determined:

– The referred test case 6.5D.3 in TS 38.521-2 [9] is incomplete

6.5B.3.4.1D.1 Test purpose

Same test purpose as in clause 6.5D.3.1 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.1D.2 Test applicability

This test case applies to all types of E-UTRA UE release 15 and forward, supporting inter-band EN-DC FR2.

6.5B.3.4.1D.3 Minimum conformance requirements

Same minimum conformance requirements as in clause 6.5D.3.1 in TS 38.521-2 [9] for the NR carrier.

No exception requirements applicable to NR or E-UTRA. LTE anchor agnostic approach is applied.

The normative reference for this measurement is TS 38.101-3 [4] clause 6.5B.3.4.

6.5B.3.4.1D.4 Test Description

Same test description as in clause 6.5D.3.1 in TS 38.521-2 [9] for the NR carrier with the following exceptions:

The initial test configurations for E-UTRA consist of test frequency based on E-UTRA operating band and test channel bandwidth as specified in Table 4.6-1.

For Initial conditions as in clause 6.5D.3.1 in TS 38.521-2 [9], the following steps will be added to configure E-UTRA component:

2.1. The parameter settings for the cell are set up according to TS 36.508 [11] subclause 4.4.3.

3.1. The E-UTRA downlink signal level, uplink signal level are set according to Table 4.6-1 and propagation conditions are set according to Annex B.0 of TS 36.521-1 [10].

Step 6 of Initial conditions as in clause 6.5D.3.1 in TS 38.521-2 [9] is replaced by:

6. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508 [6] clause 4.5.

7. On the E-UTRA carrier, disable periodic and aperiodic CQI reports, disable SRS, set TimeAlignmentTimerDedicated IE to infinity and disable downlink and uplink scheduling, all as per Table 4.6-1 under clause 4.6.

6.5B.3.4.1D.5 Test Requirement

Same test requirement as specified in clause 6.5D.3.1.5 of TS 38.521-2 [9] for the NR carrier(s).

6.5B.3.4.2 Spurious emission band UE co-existence for Inter-band including FR2 (1 NR CC)

Editor’s note: The following aspects are either missing or not yet determined:

– The referred test case 6.5.3.2 in TS 38.521-2 [9] is incomplete for PC1, PC2 and PC4.

6.5B.3.4.2.1 Test purpose

Same test purpose as in clause 6.5.3.2.1 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.2.2 Test applicability

This test case applies to all types of E-UTRA UE release 15 and forward, supporting inter-band EN-DC including FR2 with 1 NR UL CC.

6.5B.3.4.2.3 Minimum conformance requirements

Same minimum conformance requirements as in clause 6.5.3.2.3 in TS 38.521-2 [9] for the NR carrier.

No exception requirements applicable to NR or E-UTRA. LTE anchor agnostic approach is applied.

The normative reference for this requirement is TS 38.101-3 [4] clause 6.5B.3.4.1.

6.5B.3.4.2.4 Test description

Same Test description as in clause 6.5.3.2.4 in TS 38.521-2 [9] for the NR carrier with the following exception:

The initial test configurations for E-UTRA band consist of environmental conditions, test frequencies, and channel bandwidths based on E-UTRA bands specified in Table 4.7-1.

For initial conditions as in clause 6.5.3.2.4.1 in TS 38.521-2 [9], the following steps will be added to configure E-UTRA component:

2.1 The parameter settings for E-UTRA cell are set up according to TS 36.508 [11] clause 4.4.3.

3.1 The E-UTRA downlink signal level, uplink signal level are set according to Table 4.7-1 and propagation conditions are set according to Annex B.0 of TS 36.521-1 [10].

Step 6 of Initial conditions as in clause 6.5.3.2.4.1 in TS 38.521-2 [9] is replaced by:

6. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508-1 [6] clause 4.5.

Same test procedure as in clause 6.5.3.2.4.1 in TS 38.521-2 [9] with the following steps added for E-UTRA component:

1.1 On the E-UTRA carrier, disable periodic and aperiodic CQI reports, disable SRS, set TimeAlignmentTimerDedicated IE to infinity and disable downlink and uplink scheduling, all as per Table 4.7-1 under clause 4.7.

6.5B.3.4.2.5 Test requirement

Same Test requirement as in clause 6.5.3.2.5 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.2_1 Spurious emission band UE co-existence for Inter-band EN-DC including FR2 (>1 NR CC)
6.5B.3.4.2_1.1 Spurious emission band UE co-existence for Inter-band EN-DC including FR2 (2 NR CCs)

Editor’s note: The following aspects are either missing or not yet determined:

– The referred test case 6.5A.3.2.1 in TS 38.521-2 [9] is incomplete for:

▪ Testability and relaxation of the requirement for Bands other than n257, n258, n260 and n261

▪ MU and TT for Power classes 1, 2 and 4

▪ TP analysis

6.5B.3.4.2_1.1.1 Test purpose

Same test purpose as in clause 6.5.3.2 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.2_1.1.2 Test applicability

This test case applies to all types of E-UTRA UE release 15 and forward, supporting inter-band EN-DC including FR2 with 2 NR UL CCs.

6.5B.3.4.2_1.1.3 Minimum conformance requirements

Same minimum conformance requirements as in clause 6.5.3.2 in TS 38.521-2 [9] for the NR carrier.

No exception requirements applicable to NR or E-UTRA. LTE anchor agnostic approach is applied.

The normative reference for this requirement is TS 38.101-3 [4] clause 6.4B.3.2.

6.5B.3.4.2_1.1.4 Test description

6.5B.3.4.2_1.1.4.1 Initial condition

Same test description as in clause 6.5A.3.2.1.4 in TS 38.521-2 [9] for the NR carrier with the following exception:

The initial test configurations for E-UTRA band consist of environmental conditions, test frequencies, and channel bandwidths based on E-UTRA bands specified in Table 4.7-1.

For Initial conditions as in clause 6.5A.3.2.1.4.1 in TS 38.521-2 [9], the following steps will be added to configure E-UTRA component:

2.1. The parameter settings for E-UTRA cell are set up according to TS 36.508 [11] clause 4.4.3.

3.1. The E-UTRA downlink signal level, uplink signal level are set according to Table 4.7-1 and propagation conditions are set according to Annex B.0 of TS 36.521-1 [10].

Step 6 of Initial conditions as in clause 6.5A.3.2.1.4.1 in TS 38.521-2 [9] is replaced by:

6. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508-1 [6] clause 4.5.

Same test procedure as in clause 6.5A.3.2.1.4.2 in TS 38.521-2 [9] with the following steps added for E-UTRA component:

1.1 On the E-UTRA carrier, disable periodic and aperiodic CQI reports, disable SRS, set TimeAlignmentTimerDedicated IE to infinity and disable downlink and uplink scheduling, all as per Table 4.7-1 under clause 4.7.

6.5B.3.4.2_1.1.5 Test Requirements

Same test requirement as in clause 6.5A.3.2.1.5 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.2_1.2 Spurious emission band UE co-existence for Inter-band EN-DC including FR2 (3 NR CCs)

Editor’s note: The following aspects are either missing or not yet determined:

– The referred test case 6.5A.3.2.2 in TS 38.521-2 [9] is incomplete for:

▪ Testability and relaxation of the requirement for Bands other than n257, n258, n260 and n261

▪ MU and TT for Power classes 1, 2 and 4

▪ TP analysis

6.5B.3.4.2_1.2.1 Test purpose

Same test purpose as in clause 6.5.3.2 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.2_1.2.2 Test applicability

This test case applies to all types of E-UTRA UE release 15 and forward, supporting inter-band EN-DC including FR2 with 3 NR UL CCs.

6.5B.3.4.2_1.2.3 Minimum conformance requirements

Same minimum conformance requirements as in clause 6.5.3.3 in TS 38.521-2 [9] for the NR carrier.

No exception requirements applicable to NR or E-UTRA. LTE anchor agnostic approach is applied.

The normative reference for this requirement is TS 38.101-3 [4] clause 6.4B.3.4.

6.5B.3.4.2_1.2.4 Test description

6.5B.3.4.2_1.2.4.1 Initial condition

Same test description as in clause 6.5A.3.2.2.4 in TS 38.521-2 [9] for the NR carrier with the following exception:

The initial test configurations for E-UTRA band consist of environmental conditions, test frequencies, and channel bandwidths based on E-UTRA bands specified in Table 4.7-1.

For Initial conditions as in clause 6.5A.3.2.2.4.1 in TS 38.521-2 [9], the following steps will be added to configure E-UTRA component:

2.1. The parameter settings for E-UTRA cell are set up according to TS 36.508 [11] clause 4.4.3.

3.1. The E-UTRA downlink signal level, uplink signal level are set according to Table 4.7-1 and propagation conditions are set according to Annex B.0 of TS 36.521-1 [10].

Step 6 of Initial conditions as in clause 6.5A.3.2.2.4.1 in TS 38.521-2 [9] is replaced by:

6. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508-1 [6] clause 4.5.

Same test procedure as in clause 6.5A.3.2.2.4.2 in TS 38.521-2 [9] with the following steps added for E-UTRA component:

1.1 On the E-UTRA carrier, disable periodic and aperiodic CQI reports, disable SRS, set TimeAlignmentTimerDedicated IE to infinity and disable downlink and uplink scheduling, all as per Table 4.7-1 under clause 4.7.

6.5B.3.4.2_1.2.5 Test Requirements

Same test requirement as in clause 6.5A.3.2.2.5 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.2_1.3 Spurious emission band UE co-existence for Inter-band EN-DC including FR2 (4 NR CCs)

Editor’s note: The following aspects are either missing or not yet determined:

– The referred test case 6.5A.3.2.3 in TS 38.521-2 [9] is incomplete for:

▪ Testability and relaxation of the requirement for Bands other than n257, n258, n260 and n261

▪ MU and TT for Power classes 1, 2 and 4

▪ TP analysis

6.5B.3.4.2_1.3.1 Test purpose

Same test purpose as in clause 6.5.3.1 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.4.2_1.3.2 Test applicability

This test case applies to all types of E-UTRA UE release 15 and forward, supporting inter-band EN-DC including FR2 with 4 NR UL CCs.

6.5B.3.4.2_1.3.3 Minimum conformance requirements

Same minimum conformance requirements as in clause 6.5.3.3 in TS 38.521-2 [9] for the NR carrier.

No exception requirements applicable to NR or E-UTRA. LTE anchor agnostic approach is applied.

The normative reference for this requirement is TS 38.101-3 [4] clause 6.4B.3.4.

6.5B.3.4.2_1.3.4 Test description

6.5B.3.4.2_1.3.4.1 Initial condition

Same test description as in clause 6.5A.3.2.3.4 in TS 38.521-2 [9] for the NR carrier with the following exception:

The initial test configurations for E-UTRA band consist of environmental conditions, test frequencies, and channel bandwidths based on E-UTRA bands specified in Table 4.7-1.

For Initial conditions as in clause 6.5A.3.2.3.4.1 in TS 38.521-2 [9], the following steps will be added to configure E-UTRA component:

2.1. The parameter settings for E-UTRA cell are set up according to TS 36.508 [11] clause 4.4.3.

3.1. The E-UTRA downlink signal level, uplink signal level are set according to Table 4.7-1 and propagation conditions are set according to Annex B.0 of TS 36.521-1 [10].

Step 6 of Initial conditions as in clause 6.5A.3.2.3.4.1 in TS 38.521-2 [9] is replaced by:

6. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508-1 [6] clause 4.5.

Same test procedure as in clause 6.5A.3.2.3.4.2 in TS 38.521-2 [9] with the following steps added for E-UTRA component:

1.1 On the E-UTRA carrier, disable periodic and aperiodic CQI reports, disable SRS, set TimeAlignmentTimerDedicated IE to infinity and disable downlink and uplink scheduling, all as per Table 4.7-1 under clause 4.7.

6.5B.3.4.2_1.3.5 Test Requirements

Same test requirement as in clause 6.5A.3.2.3.5 in TS 38.521-2 [9] for the NR carrier.

6.5B.4.4 Additional Spurious Emissions for Inter-band including FR2 (1 NR CC)

Editor’s note: This clause is complete for Band n257 and n258 and PC3. The following aspects are either missing or not yet determined:

– The referred test case 6.5.3 in TS 38.521-2 [9] is incomplete for frequency above 80 GHz.

6.5B.4.4.1 Test purpose

Same test purpose as in clause 6.5.3.3.1 in TS 38.521-2 [9] for the NR carrier.

6.5B.4.4.2 Test applicability

This test case applies to all types of E-UTRA UE release 15 and forward, supporting inter-band EN-DC including FR2 with 1 NR UL CC.

6.5B.4.4.3 Minimum conformance requirements

Same minimum conformance requirements as in clause 6.5.3.3.3 in TS 38.521-2 [9] for the NR carrier.

No exception requirements applicable to NR or LTE. LTE anchor agnostic approach is applied.

The normative reference for this requirement is TS 38.101-3 [4] clause 6.5B.4.5.

6.5B.4.4.4 Test description

Same test description as in clause 6.5.3.3.4 in TS 38.521-2 [9] for the NR carrier with the following exception:

The initial test configurations for E-UTRA band consist of environmental conditions, test frequencies, and channel bandwidths based on E-UTRA bands specified in Table 4.6-1.

For Initial conditions as in clause 6.5.3.3.4.1 in TS 38.521-2 [9], the following steps will be added to configure E-UTRA component:

2.1 The parameter settings for E-UTRA cell are set up according to TS 36.508 [11] clause 4.4.3.

3.1 The E-UTRA downlink signal level, uplink signal level are set according to Table 4.7-1 and propagation conditions are set according to Annex B.0 of TS 36.521-1 [10].

Step 6 of Initial conditions as in clause 6.5.3.3.4.1 in TS 38.521-2 [9] is replaced by:

6. Ensure the UE is in state RRC_CONNECTED with generic procedure parameters Connectivity EN-DC, DC bearer MCG and SCG, Connected without release On according to TS 38.508-1 [6] clause 4.5.

Same test procedure as in clause 6.5.3.3.4.2 in TS 38.521-2 [9] with the following steps added for E-UTRA component:

1.1 On the E-UTRA carrier, disable periodic and aperiodic CQI reports, disable SRS, set TimeAlignmentTimerDedicated IE to infinity and disable downlink and uplink scheduling, all as per Table 4.7-1 under clause 4.7.

6.5B.4.4.5 Test requirement

Same test requirement as in clause 6.5.3.3.5 in TS 38.521-2 [9] for the NR carrier.

6.5B.3.5 Spurious emissions for Inter-band including FR1 and FR2

6.5B.3.5.1 General Spurious Emissions for Inter-band including FR1 and FR2

6.5B.3.5.1.1 Test purpose

Same test purpose as in clause 6.5.3 in TS 38.521-1 [8] for NR FR1 carrier(s) and clause 6.5.3 in TS 38.521-2 [9] for NR FR2 carrier(s).

6.5B.3.5.1.2 Test applicability

The requirements in this test are not testable due to issues with combined testing of NR FR1 and E-UTRA in conducted mode with NR FR2 in radiated mode. Therefore, the conducted and radiated requirements are tested separately.

No test case details are specified. The EN-DC requirements for spurious emissions apply and are tested as part of the EN-DC within FR1 and EN-DC including FR2 test cases in clause 6.5B.3.

6.5B.3.5.2 Spurious emission band UE co-existence for Inter-band including FR1 and FR2

6.5B.3.5.2.1 Test purpose

Same test purpose as in clause 6.5.3 in TS 38.521-1 [8] for NR FR1 carrier(s) and clause 6.5.3 in TS 38.521-2 [9] for NR FR2 carrier(s).

6.5B.3.5.2.2 Test applicability

The requirements in this test are not testable due to issues with combined testing of NR FR1 and E-UTRA in conducted mode with NR FR2 in radiated mode. Therefore, the conducted and radiated requirements are tested separately.

No test case details are specified. The EN-DC requirements for spurious emissions apply and are tested as part of the EN-DC within FR1 and EN-DC including FR2 test cases in clause 6.5B.3.